Chen A, Harris ZB, Virk A, Abazari A, Varadaraj K, Honkanen R, Arbab MH. Assessing Corneal Endothelial Damage Using Terahertz Time-Domain Spectroscopy and Support Vector Machines. SENSORS (BASEL, SWITZERLAND) 2022; 22:9071. [PMID: 36501773 PMCID: PMC9735956 DOI: 10.3390/s22239071] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/16/2022] [Accepted: 11/19/2022] [Indexed: 06/17/2023]
Abstract
The endothelial layer of the cornea plays a critical role in regulating its hydration by actively controlling fluid intake in the tissue via transporting the excess fluid out to the aqueous humor. A damaged corneal endothelial layer leads to perturbations in tissue hydration and edema, which can impact corneal transparency and visual acuity. We utilized a non-contact terahertz (THz) scanner designed for imaging spherical targets to discriminate between ex vivo corneal samples with intact and damaged endothelial layers. To create varying grades of corneal edema, the intraocular pressures of the whole porcine eye globe samples (n = 19) were increased to either 25, 35 or 45 mmHg for 4 h before returning to normal pressure levels at 15 mmHg for the remaining 4 h. Changes in tissue hydration were assessed by differences in spectral slopes between 0.4 and 0.8 THz. Our results indicate that the THz response of the corneal samples can vary according to the differences in the endothelial cell density, as determined by SEM imaging. We show that this spectroscopic difference is statistically significant and can be used to assess the intactness of the endothelial layer. These results demonstrate that THz can noninvasively assess the corneal endothelium and provide valuable complimentary information for the study and diagnosis of corneal diseases that perturb the tissue hydration.
Collapse
Affiliation(s)
- Andrew Chen
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Zachery B. Harris
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Arjun Virk
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Azin Abazari
- Department of Ophthalmology, Renaissance School of Medicine, 101 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Kulandaiappan Varadaraj
- Department of Physiology and Biophysics, Renaissance School of Medicine, 101 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Robert Honkanen
- Department of Ophthalmology, Renaissance School of Medicine, 101 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Mohammad Hassan Arbab
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| |
Collapse
|
2
|
Chen A, Virk A, Harris Z, Abazari A, Honkanen R, Arbab MH. Non-contact terahertz spectroscopic measurement of the intraocular pressure through corneal hydration mapping. BIOMEDICAL OPTICS EXPRESS 2021; 12:3438-3449. [PMID: 34221670 PMCID: PMC8221940 DOI: 10.1364/boe.423741] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 05/03/2021] [Accepted: 05/04/2021] [Indexed: 05/03/2023]
Abstract
Elevated intraocular pressure (IOP) results in endothelial layer damage that can induce corneal hydration perturbations. We investigated the potential of terahertz spectroscopy in measuring the IOP levels through mapping corneal water content. We controlled the IOP levels in ex vivo rabbit and porcine eye samples while monitoring the change in corneal hydration using a terahertz time-domain spectroscopy (THz-TDS) scanner. Our results showed a statistically significant increase in the THz reflectivity between 0.4 and 0.6 THz corresponding to the increase in the IOP. Endothelial layer damage was confirmed using scanning electron microscopy (SEM) of the corneal biopsy samples. Our empirical results indicate that the THz-TDS can be used to track IOP levels through the changes in corneal hydration.
Collapse
Affiliation(s)
- Andrew Chen
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Arjun Virk
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Zachery Harris
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Azin Abazari
- Department of Ophthalmology, Renaissance School of Medicine, 101 Nicolls Rd, Stony Brook, NY 11794, USA
| | - Robert Honkanen
- Department of Ophthalmology, Renaissance School of Medicine, 101 Nicolls Rd, Stony Brook, NY 11794, USA
| | - M. Hassan Arbab
- Department of Biomedical Engineering, Stony Brook University, 100 Nicolls Rd, Stony Brook, NY 11794, USA
| |
Collapse
|
3
|
Ke L, Wu QYS, Zhang N, Yang Z, Teo EPW, Mehta JS, Liu YC. Terahertz spectroscopy analysis of human corneal sublayers. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210014SSRR. [PMID: 33899380 PMCID: PMC8071781 DOI: 10.1117/1.jbo.26.4.043011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 03/29/2021] [Indexed: 06/12/2023]
Abstract
SIGNIFICANCE Corneal diseases is a major cause of reversible blindness in the world. Monitoring the progression of human corneal edema or corneal scarring to prevent the disease entering into the end stage is crucial. AIM We present a method for sensing human corneal composition at different depths, namely focused on the epithelium and stromal layer, using high-sensitivity terahertz (THz) broadband spectroscopy. APPROACH From the proposed methodology, the THz temporal and absorption spectra of human corneas at different edema stages have been studied. THz wave signals were collected from the direct reflection and four other collection points along the THz wave propagation direction as reviewed from the simulation THz electrical field. RESULT Our results show that the epithelium layer acts as a good barrier to maintain hydration level of the stroma, and the quality of the epithelium can be used to predict the level of corneal swelling in corneal edema. At the detection points near to the incident point, the THz frequency spectra demonstrated interference oscillation behavior. At the final edema observing time, results showed that the epithelium lose its barrier properties. The intactness of the epithelium can be used to predict the edema severity in the final stage. When the detection points are further away from the incident point, the THz spectra are believed to contain information from stromal layer. Stromal absorption spectra demonstrated correlation with optical coherence tomography thickness results. CONCLUSION The hydration concentration from stromal layer was further quantitatively calculated. At the end of the experiment, all the corneal hydration levels reach to the same value which shows that the edema hydration has reached maximum saturation. The information of individual sublayers of the cornea is obtained by characterizing noninvasively with the use of THz spectroscopy. To our knowledge, this is the first report of using THz for noninvasive characterization of sublayers of the cornea.
Collapse
Affiliation(s)
- Lin Ke
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore
| | - Qing Yang Steve Wu
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore
| | - Nan Zhang
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore
| | - Zaifeng Yang
- Institute of High Performance Computing, Agency for Science, Technology and Research, Singapore
| | | | - Jodhbir S. Mehta
- Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Ophthalmology and Visual Science Academic Clinical Research Program, Singapore
| | - Yu-Chi Liu
- Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Duke-NUS Medical School, Ophthalmology and Visual Science Academic Clinical Research Program, Singapore
| |
Collapse
|
4
|
Liu YC, Ke L, Yang SWQ, Nan Z, Teo EPW, Lwin NC, Lin MTY, Lee IXY, Chan ASY, Schmetterer L, Mehta JS. Safety profiles of terahertz scanning in ophthalmology. Sci Rep 2021; 11:2448. [PMID: 33510290 PMCID: PMC7843699 DOI: 10.1038/s41598-021-82103-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 01/15/2021] [Indexed: 01/20/2023] Open
Abstract
Terahertz (THz) technology has emerged recently as a potential novel imaging modality in biomedical fields, including ophthalmology. However, the ocular biological responses after THz electromagnetic exposure have not been investigated. We conducted a rabbit study to evaluate the safety profiles of THz scanning on eyes, at a tissue, cellular, structural and functional level. Eight animals (16 eyes) were analysed after excessive THz exposure (control, 1 h, 4 h, and 1 week after continuous 4-h exposure; THz frequency = 0.3 THz with continuous pulse generated at 40 µW). We found that at all the time points, the corneas and lens remained clear with no corneal haze or lens opacity formation clinically and histopathologically. No thermal effect, assessed by thermographer, was observed. The rod and cone cell-mediated electroretinography responses were not significantly altered, and the corneal keratocytes activity as well as endothelial viability, assessed by in-vivo confocal microscopy, was not affected. Post-exposed corneas, lens and retinas exhibited no significant changes in the mRNA expression of heat shock protein (HSP)90AB1), DNA damage inducible transcript 3 (DDIT3), and early growth response (EGR)1. These tissues were also negative for the inflammatory (CD11b), fibrotic (fibronectin and α-smooth muscle actin), stress (HSP-47) and apoptotic (TUNEL assay) responses on the immunohistochemical analyses. The optical transmittance of corneas did not change significantly, and the inter-fibrillar distances of the corneal stroma evaluated with transmission electron microscopy were not significantly altered after THz exposure. These results provide the basis for future research work on the development of THz imaging system for its application in ophthalmology.
Collapse
Affiliation(s)
- Yu-Chi Liu
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore. .,Singapore National Eye Centre, Singapore, Singapore. .,Ophthalmology and Visual Science Academic Clinical Research Program, Duke-NUS Medical School, Singapore, Singapore.
| | - Lin Ke
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore, Singapore
| | - Steve Wu Qing Yang
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore, Singapore
| | - Zhang Nan
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore, Singapore
| | - Ericia Pei Wen Teo
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore
| | - Nyein Chan Lwin
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore
| | - Molly Tzu-Yu Lin
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore
| | - Isabelle Xin Yu Lee
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore
| | - Anita Sook-Yee Chan
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore.,Singapore National Eye Centre, Singapore, Singapore.,Ophthalmology and Visual Science Academic Clinical Research Program, Duke-NUS Medical School, Singapore, Singapore
| | - Leopold Schmetterer
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore.,Ophthalmology and Visual Science Academic Clinical Research Program, Duke-NUS Medical School, Singapore, Singapore.,School of Chemical and Biomedcial Engineering, Nanyang Technological University, Singapore, Singapore.,Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.,Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - Jodhbir S Mehta
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Level 12, Singapore, 169856, Singapore.,Singapore National Eye Centre, Singapore, Singapore.,Ophthalmology and Visual Science Academic Clinical Research Program, Duke-NUS Medical School, Singapore, Singapore
| |
Collapse
|
5
|
Yao J, Ma J, Zhao J, Qi P, Li M, Lin L, Sun L, Wang X, Liu W, Wang Y. Corneal hydration assessment indicator based on terahertz time domain spectroscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:2073-2084. [PMID: 32341867 PMCID: PMC7173912 DOI: 10.1364/boe.387826] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 03/10/2020] [Accepted: 03/12/2020] [Indexed: 06/11/2023]
Abstract
Terahertz technology has shown broad prospects for measuring corneal water content, which is an important parameter of ocular health. Based on terahertz time-domain spectroscopy, a new indicator named characteristic ratio (CR) of the sum of low (0.2-0.7 THz) and high (0.7-1.0 THz) frequency spectral intensities, for characterizing corneal hydration is introduced in this work. CR is calculated from the real-time reflection spectra after error elimination of ex vivo human corneal stroma samples which is collected during dehydration under natural conditions (temperature: 22.4 ± 0.3°C; humidity: 20.0 ± 3%). The corresponding relationships between CR and corneal water content are reported. Comparing the linear fitting results with the published similar study, the coefficients of variation of the fitting slope and intercept are 39.4% and 27.6% lower, respectively. This indicates that this approach has the potential to achieve corneal water content in-vivo detection in the future.
Collapse
Affiliation(s)
- Jiali Yao
- Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China
| | - Jiaonan Ma
- Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin 300020, China
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070, China
| | - Jiehui Zhao
- Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China
| | - Pengfei Qi
- School of Physics, State Key Laboratory for Mesoscopic Physics, Academy for Advanced Interdisciplinary Studies, Collaborative Innovation Center of Quantum Matter, Nano-optoelectronics Frontier Center of Ministry of Education, Peking University, Beijing 100871, China
| | - Mengdi Li
- Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin 300020, China
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070, China
| | - Lie Lin
- Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China
| | - Lu Sun
- Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China
- Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Normal University, Guangxi, China
| | - Xiaolei Wang
- Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China
| | - Weiwei Liu
- Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China
| | - Yan Wang
- Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin 300020, China
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070, China
| |
Collapse
|
6
|
Liu YC, Ke L, Mehta JS. Evaluation of Corneal Oedema – Tools we Have and Those Under Investigation. ACTA ACUST UNITED AC 2019. [DOI: 10.17925/eor.2019.13.2.76] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|