1
|
Keijnemans K, Borman PTS, Raaymakers BW, Fast MF. Effectiveness of visual biofeedback-guided respiratory-correlated 4D-MRI for radiotherapy guidance on the MR-linac. Magn Reson Med 2024; 91:297-311. [PMID: 37799101 DOI: 10.1002/mrm.29857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 08/18/2023] [Accepted: 08/18/2023] [Indexed: 10/07/2023]
Abstract
PURPOSE Respiratory-correlated 4D-MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D-MRI acquisitions on an MR-linac. METHODS A simultaneous multislice-accelerated 4D-MRI sequence was interleaved with a one-dimensional respiratory navigator (1D-RNAV) in 10 healthy volunteers on a 1.5T Unity MR-linac (Elekta AB, Stockholm, Sweden). Volunteer-specific breathing amplitudes and periods were derived from the 1D-RNAV signal obtained during unguided 4D-MRI acquisitions. These were used for the guidance waveform, while the 1D-RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation (CV diff $$ {\mathrm{CV}}^{\mathrm{diff}} $$ ) for the breathing amplitude and period, the position SD of end-exhale, end-inhale and midposition locations, and the agreement between the 1D-RNAV signals and guidance waveforms. The 4D-MRI quality was assessed by quantifying amounts of missing data. RESULTS VBF had an average latency of 520 ± 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from -3% to 35% (end-exhale), 29% to 38% (end-inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D-RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%. CONCLUSION A VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D-MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory-correlated 4D-MRI.
Collapse
Affiliation(s)
- Katrinus Keijnemans
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Pim T S Borman
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Bas W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
2
|
Kaduk SI, Roberts AP, Stanton NA. Circadian effect on physiology and driving performance in semi-automated vehicles. THEORETICAL ISSUES IN ERGONOMICS SCIENCE 2022. [DOI: 10.1080/1463922x.2022.2121440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Affiliation(s)
| | - A. P. Roberts
- Transportation Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - N. A. Stanton
- School of Civil Engineering and the Environment, University of Southampton, Southampton, UK
| |
Collapse
|
3
|
Kim T, Lewis BC, Price A, Mazur T, Gach HM, Park JC, Cai B, Wittland E, Henke L, Kim H, Mutic S, Green O. Direct tumor visual feedback during free breathing in 0.35T MRgRT. J Appl Clin Med Phys 2020; 21:241-247. [PMID: 32931649 PMCID: PMC7592976 DOI: 10.1002/acm2.13016] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 07/12/2020] [Accepted: 07/29/2020] [Indexed: 12/25/2022] Open
Abstract
To present a tumor motion control system during free breathing using direct tumor visual feedback to patients in 0.35 T magnetic resonance-guided radiotherapy (MRgRT). We present direct tumor visualization to patients by projecting real-time cine MR images on an MR-compatible display system inside a 0.35 T MRgRT bore. The direct tumor visualization included anatomical images with a target contour and an auto-segmented gating contour. In addition, a beam-status sign was added for patient guidance. The feasibility was investigated with a six-patient clinical evaluation of the system in terms of tumor motion range and beam-on time. Seven patients without visual guidance were used for comparison. Positions of the tumor and the auto-segmented gating contour from the cine MR images were used in probability analysis to evaluate tumor motion control. In addition, beam-on time was recorded to assess the efficacy of the visual feedback system. The direct tumor visualization system was developed and implemented in our clinic. The target contour extended 3 mm outside of the gating contour for 33.6 ± 24.9% of the time without visual guidance, and 37.2 ± 26.4% of the time with visual guidance. The average maximum motion outside of the gating contour was 14.4 ± 11.1 mm without and 13.0 ± 7.9 mm with visual guidance. Beam-on time as a percentage was 43.9 ± 15.3% without visual guidance, and 48.0 ± 21.2% with visual guidance, but was not significantly different (P = 0.34). We demonstrated the clinical feasibility and potential benefits of presenting direct tumor visual feedback to patients in MRgRT. The visual feedback allows patients to visualize and attempt to minimize tumor motion in free breathing. The proposed system and associated clinical workflow can be easily adapted for any type of MRgRT.
Collapse
Affiliation(s)
- Taeho Kim
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Benjamin C. Lewis
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Alex Price
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Thomas Mazur
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - H. Michael Gach
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
- Department of Radiology and Biomedical EngineeringWashington University in St. LouisSt LouisMO63110USA
| | - Justin C. Park
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Bin Cai
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Erin Wittland
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Lauren Henke
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Hyun Kim
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Sasa Mutic
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| | - Olga Green
- Department of Radiation OncologyWashington University School of MedicineSt LouisMO63110USA
| |
Collapse
|
4
|
Massaroni C, Nicolò A, Lo Presti D, Sacchetti M, Silvestri S, Schena E. Contact-Based Methods for Measuring Respiratory Rate. SENSORS (BASEL, SWITZERLAND) 2019; 19:E908. [PMID: 30795595 PMCID: PMC6413190 DOI: 10.3390/s19040908] [Citation(s) in RCA: 137] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 02/15/2019] [Accepted: 02/17/2019] [Indexed: 01/05/2023]
Abstract
There is an ever-growing demand for measuring respiratory variables during a variety of applications, including monitoring in clinical and occupational settings, and during sporting activities and exercise. Special attention is devoted to the monitoring of respiratory rate because it is a vital sign, which responds to a variety of stressors. There are different methods for measuring respiratory rate, which can be classed as contact-based or contactless. The present paper provides an overview of the currently available contact-based methods for measuring respiratory rate. For these methods, the sensing element (or part of the instrument containing it) is attached to the subject's body. Methods based upon the recording of respiratory airflow, sounds, air temperature, air humidity, air components, chest wall movements, and modulation of the cardiac activity are presented. Working principles, metrological characteristics, and applications in the respiratory monitoring field are presented to explore potential development and applicability for each method.
Collapse
Affiliation(s)
- Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| | - Andrea Nicolò
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", 00135 Rome, Italy.
| | - Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| | - Massimo Sacchetti
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", 00135 Rome, Italy.
| | - Sergio Silvestri
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.
| |
Collapse
|
5
|
Lee SY, Lim S, Ma SY, Yu J. Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer. Radiat Oncol J 2017; 35:274-280. [PMID: 29037025 PMCID: PMC5647759 DOI: 10.3857/roj.2017.00444] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 09/18/2017] [Accepted: 09/28/2017] [Indexed: 12/25/2022] Open
Abstract
Purpose To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%–60%, 30%–70%, and 0%–90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion As narrow as possible duty cycle such as 40%–60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.
Collapse
Affiliation(s)
- Soo Yong Lee
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Sangwook Lim
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Sun Young Ma
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Jesang Yu
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| |
Collapse
|
6
|
Nakajima Y, Kadoya N, Kanai T, Ito K, Sato K, Dobashi S, Yamamoto T, Ishikawa Y, Matsushita H, Takeda K, Jingu K. Comparison of visual biofeedback system with a guiding waveform and abdomen-chest motion self-control system for respiratory motion management. JOURNAL OF RADIATION RESEARCH 2016; 57:387-392. [PMID: 26922090 PMCID: PMC4973639 DOI: 10.1093/jrr/rrv106] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2015] [Revised: 11/17/2015] [Accepted: 12/22/2015] [Indexed: 06/05/2023]
Abstract
Irregular breathing can influence the outcome of 4D computed tomography imaging and cause artifacts. Visual biofeedback systems associated with a patient-specific guiding waveform are known to reduce respiratory irregularities. In Japan, abdomen and chest motion self-control devices (Abches) (representing simpler visual coaching techniques without a guiding waveform) are used instead; however, no studies have compared these two systems to date. Here, we evaluate the effectiveness of respiratory coaching in reducing respiratory irregularities by comparing two respiratory management systems. We collected data from 11 healthy volunteers. Bar and wave models were used as visual biofeedback systems. Abches consisted of a respiratory indicator indicating the end of each expiration and inspiration motion. Respiratory variations were quantified as root mean squared error (RMSE) of displacement and period of breathing cycles. All coaching techniques improved respiratory variation, compared with free-breathing. Displacement RMSEs were 1.43 ± 0.84, 1.22 ± 1.13, 1.21 ± 0.86 and 0.98 ± 0.47 mm for free-breathing, Abches, bar model and wave model, respectively. Period RMSEs were 0.48 ± 0.42, 0.33 ± 0.31, 0.23 ± 0.18 and 0.17 ± 0.05 s for free-breathing, Abches, bar model and wave model, respectively. The average reduction in displacement and period RMSE compared with the wave model were 27% and 47%, respectively. For variation in both displacement and period, wave model was superior to the other techniques. Our results showed that visual biofeedback combined with a wave model could potentially provide clinical benefits in respiratory management, although all techniques were able to reduce respiratory irregularities.
Collapse
Affiliation(s)
- Yujiro Nakajima
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Noriyuki Kadoya
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Takayuki Kanai
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Kengo Ito
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Kiyokazu Sato
- Department of Radiology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Suguru Dobashi
- Department of Radiological Technology, Health Sciences, Tohoku University, Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Takaya Yamamoto
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Yojiro Ishikawa
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Haruo Matsushita
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Ken Takeda
- Department of Radiological Technology, Health Sciences, Tohoku University, Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| | - Keiichi Jingu
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan
| |
Collapse
|
7
|
Pollock S, Keall R, Keall P. Breathing guidance in radiation oncology and radiology: A systematic review of patient and healthy volunteer studies. Med Phys 2016; 42:5490-509. [PMID: 26328997 DOI: 10.1118/1.4928488] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The advent of image-guided radiation therapy has led to dramatic improvements in the accuracy of treatment delivery in radiotherapy. Such advancements have highlighted the deleterious impact tumor motion can have on both image quality and radiation treatment delivery. One approach to reducing tumor motion irregularities is the use of breathing guidance systems during imaging and treatment. These systems aim to facilitate regular respiratory motion which in turn improves image quality and radiation treatment accuracy. A review of such research has yet to be performed; it was therefore their aim to perform a systematic review of breathing guidance interventions within the fields of radiation oncology and radiology. METHODS From August 1-14, 2014, the following online databases were searched: Medline, Embase, PubMed, and Web of Science. Results of these searches were filtered in accordance to a set of eligibility criteria. The search, filtration, and analysis of articles were conducted in accordance with preferred reporting items for systematic reviews and meta-analyses. Reference lists of included articles, and repeat authors of included articles, were hand-searched. RESULTS The systematic search yielded a total of 480 articles, which were filtered down to 27 relevant articles in accordance to the eligibility criteria. These 27 articles detailed the intervention of breathing guidance strategies in controlled studies assessing its impact on such outcomes as breathing regularity, image quality, target coverage, and treatment margins, recruiting either healthy adult volunteers or patients with thoracic or abdominal lesions. In 21/27 studies, significant (p < 0.05) improvements from the use of breathing guidance were observed. CONCLUSIONS There is a trend toward the number of breathing guidance studies increasing with time, indicating a growing clinical interest. The results found here indicate that further clinical studies are warranted that quantify the clinical impact of breathing guidance, along with the health technology assessment to determine the advantages and disadvantages of breathing guidance.
Collapse
Affiliation(s)
- Sean Pollock
- Radiation Physics Laboratory, University of Sydney, Sydney 2050, Australia
| | - Robyn Keall
- Central School of Medicine, University of Sydney, Sydney 2050, Australia and Hammond Care, Palliative Care and Supportive Care Service, Greenwich 2065, Australia
| | - Paul Keall
- Radiation Physics Laboratory, University of Sydney, Sydney 2050, Australia
| |
Collapse
|
8
|
To DT, Kim JP, Price RG, Chetty IJ, Glide-Hurst CK. Impact of incorporating visual biofeedback in 4D MRI. J Appl Clin Med Phys 2016; 17:128-137. [PMID: 27167270 PMCID: PMC5690930 DOI: 10.1120/jacmp.v17i3.6017] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 02/15/2016] [Accepted: 12/17/2015] [Indexed: 12/25/2022] Open
Abstract
Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4D CT. 4D MRI offers improved con-trast although long scan times and irregular breathing patterns can be limiting. To address this, visual biofeedback (VBF) was introduced into 4D MRI. Ten volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted, coronal 4D MRIs were acquired on an open 1.0T MR-SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within predetermined tolerances. 4D MRIs were acquired with and without VBF for 2- and 8-phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, and breathing regularity (end-inhale coefficient of variation, EI-COV). Three reviewers performed image quality assessment to compare artifacts with and without VBF. Respiration-induced liver motion was calculated via centroid difference analysis of end-exhale (EE) and EI liver contours. Incorporating VBF reduced 2-phase acquisition time (4.7 ± 1.0 and 5.4 ± 1.5 min with and without VBF, respectively) while reducing EI-COV by 43.8% ± 16.6%. For 8-phase acquisitions, VBF reduced acquisition time by 1.9 ± 1.6 min and EI-COVs by 38.8% ± 25.7% despite breathing rate remaining similar (11.1 ± 3.8 breaths/min with vs. 10.5 ± 2.9 without). Using VBF yielded higher duty cycles than unguided free breathing (34.4% ± 5.8% vs. 28.1% ± 6.6%, respectively). Image grading showed that out of 40 paired evaluations, 20 cases had equivalent and 17 had improved image quality scores with VBF, particularly for mid-exhale and EI. Increased liver excursion was observed with VBF, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.1± 5.8, 4.9 ± 2.1, and 1.5 ± 1.0 mm, respectively, with VBF compared to 11.9 ± 4.5, 3.7 ± 2.1, and 1.2 ± 1.4 mm without. Incorporating VBF into 4D MRI substantially reduced acquisition time, breathing irregularity, and image artifacts. However, differences in excursion were observed, thus implementation will be required throughout the RT workflow.
Collapse
|
9
|
Yu J, Choi JH, Ma SY, Jeung TS, Lim S. Comparison between audio-only and audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy. Radiat Oncol J 2015; 33:250-5. [PMID: 26484309 PMCID: PMC4607579 DOI: 10.3857/roj.2015.33.3.250] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Revised: 09/07/2015] [Accepted: 09/11/2015] [Indexed: 12/25/2022] Open
Abstract
Purpose To compare audio-only biofeedback to conventional audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy, limiting damage to healthy surrounding tissues caused by organ movement. Materials and Methods Six healthy volunteers were assisted by audiovisual or audio-only biofeedback systems to regulate their respirations. Volunteers breathed through a mask developed for this study by following computer-generated guiding curves displayed on a screen, combined with instructional sounds. They then performed breathing following instructional sounds only. The guiding signals and the volunteers' respiratory signals were logged at 20 samples per second. Results The standard deviations between the guiding and respiratory curves for the audiovisual and audio-only biofeedback systems were 21.55% and 23.19%, respectively; the average correlation coefficients were 0.9778 and 0.9756, respectively. The regularities between audiovisual and audio-only biofeedback for six volunteers' respirations were same statistically from the paired t-test. Conclusion The difference between the audiovisual and audio-only biofeedback methods was not significant. Audio-only biofeedback has many advantages, as patients do not require a mask and can quickly adapt to this method in the clinic.
Collapse
Affiliation(s)
- Jesang Yu
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Ji Hoon Choi
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Sun Young Ma
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Tae Sig Jeung
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| | - Sangwook Lim
- Department of Radiation Oncology, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea
| |
Collapse
|
10
|
He P, Li Q, Liu X, Dai Z, Zhao T, Fu T, Shen G, Ma Y, Huang Q, Yan Y. Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery. Med Phys 2015; 41:111708. [PMID: 25370622 DOI: 10.1118/1.4897391] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To efficiently deliver respiratory-gated radiation during synchrotron-based pulsed heavy-ion radiotherapy, a novel respiratory guidance method combining a personalized audio-visual biofeedback (BFB) system, breath hold (BH), and synchrotron-based gating was designed to help patients synchronize their respiratory patterns with synchrotron pulses and to overcome typical limitations such as low efficiency, residual motion, and discomfort. METHODS In-house software was developed to acquire body surface marker positions and display BFB, gating signals, and real-time beam profiles on a LED screen. Patients were prompted to perform short BHs or short deep breath holds (SDBH) with the aid of BFB following a personalized standard BH/SDBH (stBH/stSDBH) guiding curve or their own representative BH/SDBH (reBH/reSDBH) guiding curve. A practical simulation was performed for a group of 15 volunteers to evaluate the feasibility and effectiveness of this method. Effective dose rates (EDRs), mean absolute errors between the guiding curves and the measured curves, and mean absolute deviations of the measured curves were obtained within 10%-50% duty cycles (DCs) that were synchronized with the synchrotron's flat-top phase. RESULTS All maneuvers for an individual volunteer took approximately half an hour, and no one experienced discomfort during the maneuvers. Using the respiratory guidance methods, the magnitude of residual motion was almost ten times less than during nongated irradiation, and increases in the average effective dose rate by factors of 2.39-4.65, 2.39-4.59, 1.73-3.50, and 1.73-3.55 for the stBH, reBH, stSDBH, and reSDBH guiding maneuvers, respectively, were observed in contrast with conventional free breathing-based gated irradiation, depending on the respiratory-gated duty cycle settings. CONCLUSIONS The proposed respiratory guidance method with personalized BFB was confirmed to be feasible in a group of volunteers. Increased effective dose rate and improved overall treatment precision were observed compared to conventional free breathing-based, respiratory-gated irradiation. Because breathing guidance curves could be established based on the respective average respiratory period and amplitude for each patient, it may be easier for patients to cooperate using this technique.
Collapse
Affiliation(s)
- Pengbo He
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China; and School of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qiang Li
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China and Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China
| | - Xinguo Liu
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China and Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China
| | - Zhongying Dai
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China and Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China
| | - Ting Zhao
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China and Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China
| | - Tingyan Fu
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China and Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China
| | - Guosheng Shen
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China and Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China
| | - Yuanyuan Ma
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China; and School of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qiyan Huang
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China; and School of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yuanlin Yan
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Key Laboratory of Heavy Ion Radiation Biology and Medicine of Chinese Academy of Sciences, Lanzhou 730000, China; and School of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
11
|
Kim T, Kim S, Park YK, Youn KK, Keall P, Lee R. Motion management within two respiratory-gating windows: feasibility study of dual quasi-breath-hold technique in gated medical procedures. Phys Med Biol 2014; 59:6583-94. [DOI: 10.1088/0031-9155/59/21/6583] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
12
|
The internal–external respiratory motion correlation is unaffected by audiovisual biofeedback. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2014; 37:97-102. [DOI: 10.1007/s13246-014-0247-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2013] [Accepted: 01/27/2014] [Indexed: 12/22/2022]
|
13
|
Kim T, Pollock S, Lee D, O'Brien R, Keall P. Audiovisual biofeedback improves diaphragm motion reproducibility in MRI. Med Phys 2013; 39:6921-8. [PMID: 23127085 DOI: 10.1118/1.4761866] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE In lung radiotherapy, variations in cycle-to-cycle breathing results in four-dimensional computed tomography imaging artifacts, leading to inaccurate beam coverage and tumor targeting. In previous studies, the effect of audiovisual (AV) biofeedback on the external respiratory signal reproducibility has been investigated but the internal anatomy motion has not been fully studied. The aim of this study is to test the hypothesis that AV biofeedback improves diaphragm motion reproducibility of internal anatomy using magnetic resonance imaging (MRI). METHODS To test the hypothesis 15 healthy human subjects were enrolled in an ethics-approved AV biofeedback study consisting of two imaging sessions spaced ∼1 week apart. Within each session MR images were acquired under free breathing and AV biofeedback conditions. The respiratory signal to the AV biofeedback system utilized optical monitoring of an external marker placed on the abdomen. Synchronously, serial thoracic 2D MR images were obtained to measure the diaphragm motion using a fast gradient-recalled-echo MR pulse sequence in both coronal and sagittal planes. The improvement in the diaphragm motion reproducibility using the AV biofeedback system was quantified by comparing cycle-to-cycle variability in displacement, respiratory period, and baseline drift. Additionally, the variation in improvement between the two sessions was also quantified. RESULTS The average root mean square error (RMSE) of diaphragm cycle-to-cycle displacement was reduced from 2.6 mm with free breathing to 1.6 mm (38% reduction) with the implementation of AV biofeedback (p-value < 0.0001). The average RMSE of the respiratory period was reduced from 1.7 s with free breathing to 0.3 s (82% reduction) with AV biofeedback (p-value < 0.0001). Additionally, the average baseline drift obtained using a linear fit was reduced from 1.6 mm∕min with free breathing to 0.9 mm∕min (44% reduction) with AV biofeedback (p-value = 0.012). The diaphragm motion reproducibility improvements with AV biofeedback were consistent with the abdominal motion reproducibility that was observed from the external marker motion variation. CONCLUSIONS This study was the first to investigate the potential of AV biofeedback to improve the motion reproducibility of internal anatomy using MRI. The study demonstrated the significant improvement in diaphragm motion reproducibility using AV biofeedback combined with MRI. This system can potentially provide clinically beneficial motion management of internal anatomy in MRI and radiotherapy.
Collapse
Affiliation(s)
- Taeho Kim
- Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, Australia
| | | | | | | | | |
Collapse
|
14
|
Introduction to 4D Motion Modeling and 4D Radiotherapy. 4D MODELING AND ESTIMATION OF RESPIRATORY MOTION FOR RADIATION THERAPY 2013. [DOI: 10.1007/978-3-642-36441-9_1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
15
|
Otani Y, Fukuda I, Tsukamoto N, Kumazaki Y, Sekine H, Imabayashi E, Kawaguchi O, Nose T, Teshima T, Dokiya T. A comparison of the respiratory signals acquired by different respiratory monitoring systems used in respiratory gated radiotherapy. Med Phys 2010; 37:6178-86. [DOI: 10.1118/1.3512798] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
16
|
Masselli GMP, Silvestri S, Ramella S, Trodella L. Design and evaluation of a methodology to perform personalized visual biofeedback for reducing respiratory amplitude in radiation treatment. Med Phys 2009; 36:1467-72. [PMID: 19544761 DOI: 10.1118/1.3098942] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A methodology to perform personalized visual biofeedback aimed to the reduction of respiratory amplitude is here proposed. A custom-made software allows to adapt the biofeedback parameters to a patient's respiratory pattern by calculating a limiting range for respiratory amplitude obtained from data acquired during free breathing. The proposed methodology has been tested on ten healthy volunteers and on five lung cancer patients undergoing radiotherapy treatment. The protocol for volunteers consisted of 3 min of data acquisition during the subject's free breathing, 2 min of visual biofeedback within the limits, and 3 min of free breathing. The patients' free breathing was acquired in 3 min and the visual biofeedback performed during all the sessions of the radiotherapy treatment, i.e., an average of eight sessions and an average total treatment time of 2000 s each patient. All the volunteers and three patients of the five found the protocol comfortable. The settlement time needed for considering the limiting range stabilized during free breathing has been calculated as 120 +/- 10 s (p < 0.05). During visual biofeedback the baseline shift was removed and the average respiratory amplitude was reduced by about 40% for all the subjects. The variability of the breathing amplitude remained unaltered during biofeedback. Eight volunteers and three patients remained within the limiting range for more than 90% of the biofeedback period; all subjects remained within the limiting range for more than 80% of the biofeedback period. During the biofeedback period both groups, volunteers and patients, showed a significant increase in breathing frequency which was mostly doubled. Patients with shallow breathing performed comfortably the biofeedback.
Collapse
Affiliation(s)
- Grazia Maria Pia Masselli
- Faculty of Biomedical Engineering, University Hospital, University Campus Bio-Medico, Via Alvaro del Portillo, 21 00128 Rome, Italy
| | | | | | | |
Collapse
|
17
|
Venkat RB, Sawant A, Suh Y, George R, Keall PJ. Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform. Phys Med Biol 2008; 53:N197-208. [PMID: 18475007 DOI: 10.1088/0031-9155/53/11/n01] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The aim of this research was to investigate the effectiveness of a novel audio-visual biofeedback respiratory training tool to reduce respiratory irregularity. The audiovisual biofeedback system acquires sample respiratory waveforms of a particular patient and computes a patient-specific waveform to guide the patient's subsequent breathing. Two visual feedback models with different displays and cognitive loads were investigated: a bar model and a wave model. The audio instructions were ascending/descending musical tones played at inhale and exhale respectively to assist in maintaining the breathing period. Free-breathing, bar model and wave model training was performed on ten volunteers for 5 min for three repeat sessions. A total of 90 respiratory waveforms were acquired. It was found that the bar model was superior to free breathing with overall rms displacement variations of 0.10 and 0.16 cm, respectively, and rms period variations of 0.77 and 0.33 s, respectively. The wave model was superior to the bar model and free breathing for all volunteers, with an overall rms displacement of 0.08 cm and rms periods of 0.2 s. The reduction in the displacement and period variations for the bar model compared with free breathing was statistically significant (p = 0.005 and 0.002, respectively); the wave model was significantly better than the bar model (p = 0.006 and 0.005, respectively). Audiovisual biofeedback with a patient-specific guiding waveform significantly reduces variations in breathing. The wave model approach reduces cycle-to-cycle variations in displacement by greater than 50% and variations in period by over 70% compared with free breathing. The planned application of this device is anatomic and functional imaging procedures and radiation therapy delivery.
Collapse
Affiliation(s)
- Raghu B Venkat
- Department of Radiation Oncology, Stanford University, Stanford, CA 94305-5847, USA
| | | | | | | | | |
Collapse
|
18
|
Cho B, Suh Y, Dieterich S, Keall PJ. A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring. Phys Med Biol 2008; 53:2837-55. [DOI: 10.1088/0031-9155/53/11/006] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|