Zhang Z, Chen B, Xia D, Sidky EY, Pan X. Accurate image reconstruction within and beyond the field-of-view of CT system from data with truncation. Phys Med Biol 2025; 70:035005. [PMID: 39778342 PMCID: PMC11770399 DOI: 10.1088/1361-6560/ada7be] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2024] [Revised: 12/05/2024] [Accepted: 01/08/2025] [Indexed: 01/11/2025]
Abstract
Objective. Accurate image reconstruction from data with truncation in x-ray computed tomography (CT) remains a topic of research interest; and the works reported previously in the literature focus largely on reconstructing an image only within the scanning field-of-view (FOV). We develop algorithms to invert the truncated data model for numerically accurate image reconstruction within the subject support or a region slightly smaller than the subject support.Methods. We formulate image reconstruction from data with truncation as an optimization program, which includes hybrid constraints on region-based image total-variation (TV) and imageℓ1-norm (L1) for effectively suppressing truncation artifacts. An algorithm, referred to as the TV-L1 algorithm, is developed for image reconstruction (i.e. inversion of the data model) from data with truncation through solving the optimization program.Results. We perform numerical studies to evaluate accuracy and stability of the TV-L1 algorithm by using simulated and real CT data. Accurate images can be obtained stably by use of the TV-L1 algorithm within the subject support, or a region substantially larger than the FOV, from data with truncation of varying degrees.Conclusions. The TV-L1 algorithm can invert the truncated data model to accurately and stably reconstruct images within the subject support, or a region slightly smaller than the subject support but substantially larger than the FOV.Significance. Accurate image reconstruction within the subject support, or a region substantially larger than the FOV, from data with truncation can be of theoretical and practical implication. The insights and TV-L1 algorithm may also be generalized to accurate image reconstruction from data with truncation in other tomographic imaging modalities.
Collapse
Affiliation(s)
- Zheng Zhang
- Department of Radiology, The University of Chicago, Chicago, IL 60637, United States of America
| | - Buxin Chen
- Department of Radiology, The University of Chicago, Chicago, IL 60637, United States of America
| | - Dan Xia
- Department of Radiology, The University of Chicago, Chicago, IL 60637, United States of America
| | - Emil Y Sidky
- Department of Radiology, The University of Chicago, Chicago, IL 60637, United States of America
| | - Xiaochuan Pan
- Department of Radiology, The University of Chicago, Chicago, IL 60637, United States of America
- Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, United States of America
| |
Collapse
|
2
|
Zhang C, Chen GH. Deep-Interior: A new pathway to interior tomographic image reconstruction via a weighted backprojection and deep learning. Med Phys 2024; 51:946-963. [PMID: 38063251 PMCID: PMC10993302 DOI: 10.1002/mp.16880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 02/10/2024] Open
Abstract
BACKGROUND In recent years, deep learning strategies have been combined with either the filtered backprojection or iterative methods or the direct projection-to-image by deep learning only to reconstruct images. Some of these methods can be applied to address the interior reconstruction problems for centered regions of interest (ROIs) with fixed sizes. Developing a method to enable interior tomography with arbitrarily located ROIs with nearly arbitrary ROI sizes inside a scanning field of view (FOV) remains an open question. PURPOSE To develop a new pathway to enable interior tomographic reconstruction for arbitrarily located ROIs with arbitrary sizes using a single trained deep neural network model. METHODS The method consists of two steps. First, an analytical weighted backprojection reconstruction algorithm was developed to perform domain transform from divergent fan-beam projection data to an intermediate image feature space,B ( x ⃗ ) $B(\vec{x})$ , for an arbitrary size ROI at an arbitrary location inside the FOV. Second, a supervised learning technique was developed to train a deep neural network architecture to perform deconvolution to obtain the true imagef ( x ⃗ ) $f(\vec{x})$ from the new feature spaceB ( x ⃗ ) $B(\vec{x})$ . This two-step method is referred to as Deep-Interior for convenience. Both numerical simulations and experimental studies were performed to validate the proposed Deep-Interior method. RESULTS The results showed that ROIs as small as a diameter of 5 cm could be accurately reconstructed (similarity index 0.985 ± 0.018 on internal testing data and 0.940 ± 0.025 on external testing data) at arbitrary locations within an imaging object covering a wide variety of anatomical structures of different body parts. Besides, ROIs of arbitrary size can be reconstructed by stitching small ROIs without additional training. CONCLUSION The developed Deep-Interior framework can enable interior tomographic reconstruction from divergent fan-beam projections for short-scan and super-short-scan acquisitions for small ROIs (with a diameter larger than 5 cm) at an arbitrary location inside the scanning FOV with high quantitative reconstruction accuracy.
Collapse
Affiliation(s)
- Chengzhu Zhang
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Guang-Hong Chen
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| |
Collapse
|
3
|
Coussat A, Rit S, Clackdoyle R, Defrise M, Desbat L, Letang JM. Region-of-Interest CT Reconstruction Using Object Extent and Singular Value Decomposition. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022. [DOI: 10.1109/trpms.2021.3091288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Aurelien Coussat
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJMSaint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Simon Rit
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJMSaint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Rolf Clackdoyle
- TIMC-IMAG Laboratory (CNRS UMR 5525), Université Grenoble Alpes, Grenoble, France
| | - Michel Defrise
- Department of Nuclear Medicine, Vrije Universiteit Brussel, Brussels, Belgium
| | - Laurent Desbat
- TIMC-IMAG Laboratory (CNRS UMR 5525), Université Grenoble Alpes, Grenoble, France
| | - Jean Michel Letang
- Université de Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJMSaint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
4
|
Tan C, Yu H, Xi Y, Li L, Liao M, Liu F, Duan L. Multi source translation based projection completion for interior region of interest tomography with CBCT. OPTICS EXPRESS 2022; 30:2963-2980. [PMID: 35209426 DOI: 10.1364/oe.442287] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 12/29/2021] [Indexed: 06/14/2023]
Abstract
Interior tomography by rotary computed tomography (RCT) is an effective method to improve the detection efficiency and achieve high-resolution imaging for the region of interest (ROI) within a large-scale object. However, because only the X-rays through the ROI can be received by detector, the projection data is inevitably truncated, resulting in truncation artifacts in the reconstructed image. When the ROI is totally within the object, the solution of the problem is not unique, which is named interior problem. Fortunately, projection completion (PC) is an effective technique to solve the interior problem. In this study, we proposed a multi source translation CT based PC method (mSTCT-PC) to cope with the interior problem. Firstly, mSTCT-PC employs multi-source translation to sparsely obtain the global projection which covered the whole object. Secondly, the sparse global projection is utilized to fill up the truncated projection of ROI. The global projection and truncated projection are obtained under the same geometric parameters. Therefore, it omits the registration of projection. To verify the feasibility of this method, simulation and practical experiments were implemented. Compared with the results of ROI reconstructed by filtered back-projection (FBP), simultaneous iterative reconstruction technique-total variation (SIRT-TV) and the multi-resolution based method (mR-PC), the proposed mSTCT-PC is good at mitigating truncation artifacts, preserving details and improving the accuracy of ROI images.
Collapse
|
5
|
Ketola JHJ, Heino H, Juntunen MAK, Nieminen MT, Siltanen S, Inkinen SI. Generative adversarial networks improve interior computed tomography angiography reconstruction. Biomed Phys Eng Express 2021; 7. [PMID: 34673559 DOI: 10.1088/2057-1976/ac31cb] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 10/21/2021] [Indexed: 11/12/2022]
Abstract
In interior computed tomography (CT), the x-ray beam is collimated to a limited field-of-view (FOV) (e.g. the volume of the heart) to decrease exposure to adjacent organs, but the resulting image has a severe truncation artifact when reconstructed with traditional filtered back-projection (FBP) type algorithms. In some examinations, such as cardiac or dentomaxillofacial imaging, interior CT could be used to achieve further dose reductions. In this work, we describe a deep learning (DL) method to obtain artifact-free images from interior CT angiography. Our method employs the Pix2Pix generative adversarial network (GAN) in a two-stage process: (1) An extended sinogram is computed from a truncated sinogram with one GAN model, and (2) the FBP reconstruction obtained from that extended sinogram is used as an input to another GAN model that improves the quality of the interior reconstruction. Our double GAN (DGAN) model was trained with 10 000 truncated sinograms simulated from real computed tomography angiography slice images. Truncated sinograms (input) were used with original slice images (target) in training to yield an improved reconstruction (output). DGAN performance was compared with the adaptive de-truncation method, total variation regularization, and two reference DL methods: FBPConvNet, and U-Net-based sinogram extension (ES-UNet). Our DGAN method and ES-UNet yielded the best root-mean-squared error (RMSE) (0.03 ± 0.01), and structural similarity index (SSIM) (0.92 ± 0.02) values, and reference DL methods also yielded good results. Furthermore, we performed an extended FOV analysis by increasing the reconstruction area by 10% and 20%. In both cases, the DGAN approach yielded best results at RMSE (0.03 ± 0.01 and 0.04 ± 0.01 for the 10% and 20% cases, respectively), peak signal-to-noise ratio (PSNR) (30.5 ± 2.6 dB and 28.6 ± 2.6 dB), and SSIM (0.90 ± 0.02 and 0.87 ± 0.02). In conclusion, our method was able to not only reconstruct the interior region with improved image quality, but also extend the reconstructed FOV by 20%.
Collapse
Affiliation(s)
- Juuso H J Ketola
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, FI-90014, Finland.,The South Savo Social and Health Care Authority, Mikkeli Central Hospital, FI-50100, Finland
| | - Helinä Heino
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, FI-90014, Finland
| | - Mikael A K Juntunen
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, FI-90014, Finland.,Department of Diagnostic Radiology, Oulu University Hospital, FI-90029, Finland
| | - Miika T Nieminen
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, FI-90014, Finland.,Department of Diagnostic Radiology, Oulu University Hospital, FI-90029, Finland.,Medical Research Center Oulu, University of Oulu and Oulu University Hospital, FI-90014, Finland
| | - Samuli Siltanen
- Department of Mathematics and Statistics, University of Helsinki, Helsinki, FI-00014, Finland
| | - Satu I Inkinen
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, FI-90014, Finland
| |
Collapse
|
6
|
Badea CT. Principles of Micro X-ray Computed Tomography. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00006-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
7
|
Juntunen MAK, Sepponen P, Korhonen K, Pohjanen VM, Ketola J, Kotiaho A, Nieminen MT, Inkinen SI. Interior photon counting computed tomography for quantification of coronary artery calcium: pre-clinical phantom study. Biomed Phys Eng Express 2020; 6:055011. [PMID: 33444242 DOI: 10.1088/2057-1976/aba133] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Computed tomography (CT) is the reference method for cardiac imaging, but concerns have been raised regarding the radiation dose of CT examinations. Recently, photon counting detectors (PCDs) and interior tomography, in which the radiation beam is limited to the organ-of-interest, have been suggested for patient dose reduction. In this study, we investigated interior PCD-CT (iPCD-CT) for non-enhanced quantification of coronary artery calcium (CAC) using an anthropomorphic torso phantom and ex vivo coronary artery samples. We reconstructed the iPCD-CT measurements with filtered back projection (FBP), iterative total variation (TV) regularization, padded FBP, and adaptively detruncated FBP and adaptively detruncated TV. We compared the organ doses between conventional CT and iPCD-CT geometries, assessed the truncation and cupping artifacts with iPCD-CT, and evaluated the CAC quantification performance of iPCD-CT. With approximately the same effective dose between conventional CT geometry (0.30 mSv) and interior PCD-CT with 10.2 cm field-of-view (0.27 mSv), the organ dose of the heart was increased by 52.3% with interior PCD-CT when compared to CT. Conversely, the organ doses to peripheral and radiosensitive organs, such as the stomach (55.0% reduction), were often reduced with interior PCD-CT. FBP and TV did not sufficiently reduce the truncation artifact, whereas padded FBP and adaptively detruncated FBP and TV yielded satisfactory truncation artifact reduction. Notably, the adaptive detruncation algorithm reduced truncation artifacts effectively when it was combined with reconstruction detrending. With this approach, the CAC quantification accuracy was good, and the coronary artery disease grade reclassification rate was particularly low (5.6%). Thus, our results confirm that CAC quantification can be performed with the interior CT geometry, that the artifacts are effectively reduced with suitable interior reconstruction methods, and that interior tomography provides efficient patient dose reduction.
Collapse
Affiliation(s)
- Mikael A K Juntunen
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, Oulu, Finland. Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Holbrook M, Clark DP, Badea CT. Overcoming detector limitations of x-ray photon counting for preclinical microcomputed tomography. J Med Imaging (Bellingham) 2018; 6:011004. [PMID: 30840718 DOI: 10.1117/1.jmi.6.1.011004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Accepted: 07/30/2018] [Indexed: 12/21/2022] Open
Abstract
Spectral computed tomography (CT) using photon counting detectors (PCDs) can provide accurate tissue composition measurements by utilizing the energy dependence of x-ray attenuation in different materials. PCDs are especially suited for K-edge imaging, revealing the spatial distribution of select imaging probes through quantitative material decomposition. We report on a prototype spectral micro-CT system with a CZT-based PCD (DxRay, Inc.) that has 16 × 16 pixels of 0.5 × 0.5 mm 2 , a thickness of 3 mm, and four energy thresholds. Due to the PCD's limited size ( 8 × 8 mm 2 ), our system uses a translate-rotate projection acquisition strategy to cover a field of view relevant for preclinical imaging ( ∼ 4.5 cm ). Projection corrections were implemented to minimize artifacts associated with dead pixels and projection stitching. A sophisticated iterative algorithm was used to reconstruct both phantom and ex vivo mouse data. To achieve preclinically relevant spatial resolution, we trained a convolutional neural network to perform pan-sharpening between low-resolution PCD data ( 247 - μ m voxels) and high-resolution energy-integrating detector data ( 82 - μ m voxels), recovering a high-resolution estimate of the spectral contrast suitable for material decomposition. Long-term, preclinical spectral CT systems such as ours could serve in the developing field of theranostics (therapy and diagnostics) for cancer research.
Collapse
Affiliation(s)
- Matthew Holbrook
- Duke University, Center for In Vivo Microscopy, Department of Radiology, Durham, North Carolina, United States
| | - Darin P Clark
- Duke University, Center for In Vivo Microscopy, Department of Radiology, Durham, North Carolina, United States
| | - Cristian T Badea
- Duke University, Center for In Vivo Microscopy, Department of Radiology, Durham, North Carolina, United States
| |
Collapse
|
9
|
Sen Sharma K, Gong H, Ghasemalizadeh O, Yu H, Wang G, Cao G. Interior micro-CT with an offset detector. Med Phys 2015; 41:061915. [PMID: 24877826 DOI: 10.1118/1.4876724] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully. Here, the authors studied a new problem where the FOV of a micro-CT system, although increased after offset-detector acquisition, still covers an interior region-of-interest (ROI) within the object. METHODS An interior-ROI-oriented micro-CT scan with an offset detector poses a difficult reconstruction problem, which is caused by both detector offset and projection truncation. Using the projection completion techniques, the authors first extended three previous reconstruction methods from offset-detector micro-CT to offset-detector interior micro-CT. The authors then proposed a novel method which combines two of the extended methods using a frequency split technique. The authors tested the four methods with phantom simulations at 9.4%, 18.8%, 28.2%, and 37.6% detector offset. The authors also applied these methods to physical phantom datasets acquired at the same amounts of detector offset from a customized micro-CT system. RESULTS When the detector offset was small, all reconstruction methods showed good image quality. At large detector offset, the three extended methods gave either visible shading artifacts or high deviation of pixel value, while the authors' proposed method demonstrated no visible artifacts and minimal deviation of pixel value in both the numerical simulations and physical experiments. CONCLUSIONS For an interior micro-CT with an offset detector, the three extended reconstruction methods can perform well at a small detector offset but show strong artifacts at a large detector offset. When the detector offset is large, the authors' proposed reconstruction method can outperform the three extended reconstruction methods by suppressing artifacts and maintaining pixel values.
Collapse
Affiliation(s)
- Kriti Sen Sharma
- Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061
| | - Hao Gong
- VT-WFU School of Biomedical Engingeering and Sciences, Virginia Tech, Blacksburg, Virginia 24061
| | - Omid Ghasemalizadeh
- Department of Mechanical Engineering, Virginia Tech, Blacksburg, Virginia 24061
| | - Hengyong Yu
- VT-WFU School of Biomedical Engineering and Sciences, Wake Forest University Health Sciences, Winston-Salem, North Carolina 27157
| | - Ge Wang
- Biomedical Imaging Center/Cluster CBIS/BME, Rensselaer Polytechnic Institute, Troy, New York 12180
| | - Guohua Cao
- VT-WFU School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia 24061
| |
Collapse
|
10
|
Heußer T, Brehm M, Ritschl L, Sawall S, Kachelrieß M. Prior-based artifact correction (PBAC) in computed tomography. Med Phys 2014; 41:021906. [PMID: 24506627 DOI: 10.1118/1.4851536] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Image quality in computed tomography (CT) often suffers from artifacts which may reduce the diagnostic value of the image. In many cases, these artifacts result from missing or corrupt regions in the projection data, e.g., in the case of metal, truncation, and limited angle artifacts. The authors propose a generalized correction method for different kinds of artifacts resulting from missing or corrupt data by making use of available prior knowledge to perform data completion. METHODS The proposed prior-based artifact correction (PBAC) method requires prior knowledge in form of a planning CT of the same patient or in form of a CT scan of a different patient showing the same body region. In both cases, the prior image is registered to the patient image using a deformable transformation. The registered prior is forward projected and data completion of the patient projections is performed using smooth sinogram inpainting. The obtained projection data are used to reconstruct the corrected image. RESULTS The authors investigate metal and truncation artifacts in patient data sets acquired with a clinical CT and limited angle artifacts in an anthropomorphic head phantom data set acquired with a gantry-based flat detector CT device. In all cases, the corrected images obtained by PBAC are nearly artifact-free. Compared to conventional correction methods, PBAC achieves better artifact suppression while preserving the patient-specific anatomy at the same time. Further, the authors show that prominent anatomical details in the prior image seem to have only minor impact on the correction result. CONCLUSIONS The results show that PBAC has the potential to effectively correct for metal, truncation, and limited angle artifacts if adequate prior data are available. Since the proposed method makes use of a generalized algorithm, PBAC may also be applicable to other artifacts resulting from missing or corrupt data.
Collapse
Affiliation(s)
- Thorsten Heußer
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Marcus Brehm
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Ludwig Ritschl
- Ziehm Imaging GmbH, Donaustraße 31, 90451 Nürnberg, Germany
| | - Stefan Sawall
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, Friedrich-Alexander-University (FAU) of Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany
| | - Marc Kachelrieß
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, Friedrich-Alexander-University (FAU) of Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany
| |
Collapse
|
11
|
Clark DP, Badea CT. Micro-CT of rodents: state-of-the-art and future perspectives. Phys Med 2014; 30:619-34. [PMID: 24974176 PMCID: PMC4138257 DOI: 10.1016/j.ejmp.2014.05.011] [Citation(s) in RCA: 143] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 05/15/2014] [Accepted: 05/28/2014] [Indexed: 02/06/2023] Open
Abstract
Micron-scale computed tomography (micro-CT) is an essential tool for phenotyping and for elucidating diseases and their therapies. This work is focused on preclinical micro-CT imaging, reviewing relevant principles, technologies, and applications. Commonly, micro-CT provides high-resolution anatomic information, either on its own or in conjunction with lower-resolution functional imaging modalities such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). More recently, however, advanced applications of micro-CT produce functional information by translating clinical applications to model systems (e.g., measuring cardiac functional metrics) and by pioneering new ones (e.g. measuring tumor vascular permeability with nanoparticle contrast agents). The primary limitations of micro-CT imaging are the associated radiation dose and relatively poor soft tissue contrast. We review several image reconstruction strategies based on iterative, statistical, and gradient sparsity regularization, demonstrating that high image quality is achievable with low radiation dose given ever more powerful computational resources. We also review two contrast mechanisms under intense development. The first is spectral contrast for quantitative material discrimination in combination with passive or actively targeted nanoparticle contrast agents. The second is phase contrast which measures refraction in biological tissues for improved contrast and potentially reduced radiation dose relative to standard absorption imaging. These technological advancements promise to develop micro-CT into a commonplace, functional and even molecular imaging modality.
Collapse
Affiliation(s)
- D P Clark
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA
| | - C T Badea
- Center for In Vivo Microscopy, Department of Radiology, Duke University Medical Center, Box 3302, Durham, NC 27710, USA.
| |
Collapse
|
12
|
Taguchi K, Iwanczyk JS. Vision 20/20: Single photon counting x-ray detectors in medical imaging. Med Phys 2014; 40:100901. [PMID: 24089889 DOI: 10.1118/1.4820371] [Citation(s) in RCA: 481] [Impact Index Per Article: 43.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Photon counting detectors (PCDs) with energy discrimination capabilities have been developed for medical x-ray computed tomography (CT) and x-ray (XR) imaging. Using detection mechanisms that are completely different from the current energy integrating detectors and measuring the material information of the object to be imaged, these PCDs have the potential not only to improve the current CT and XR images, such as dose reduction, but also to open revolutionary novel applications such as molecular CT and XR imaging. The performance of PCDs is not flawless, however, and it seems extremely challenging to develop PCDs with close to ideal characteristics. In this paper, the authors offer our vision for the future of PCD-CT and PCD-XR with the review of the current status and the prediction of (1) detector technologies, (2) imaging technologies, (3) system technologies, and (4) potential clinical benefits with PCDs.
Collapse
Affiliation(s)
- Katsuyuki Taguchi
- Division of Medical Imaging Physics, The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21287
| | | |
Collapse
|
13
|
Tang S, Tang X. Radial differential interior tomography and its image reconstruction with differentiated backprojection and projection onto convex sets. Med Phys 2014; 40:091914. [PMID: 24007165 DOI: 10.1118/1.4812676] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
PURPOSE Interior tomography has been recognized as one of the most effective approaches in computed tomography (CT) to reduce radiation dose rendered to patients. In this work, the authors propose and evaluate an imaging method of radial differential interior tomography. METHODS In interior tomography, an x-ray beam is collimated to only irradiate the region of interest (ROI) with suspected lesions while the surrounding area∕volume of normal tissues∕organs is spared. In the proposed imaging method of radial differential interior tomography, the outcome is a ROI image that has gone through a radial differential filtering. The image reconstruction algorithm for the radial differential interior tomography is kept in the fashion of differentiated backprojection and projection onto convex sets, but the required a priori knowledge in a small round area becomes zero and may be more readily available in practice. RESULTS Using the projection data simulated by computer and acquired by CT scanner, the authors evaluate and verify the performance of the proposed radial differential interior tomography method and its associated image reconstruction algorithm. The preliminary results show that the proposed imaging method can generate an image that is the radial differentiation of a conventional tomographic image and is robust over noise that inevitably exist in practice. CONCLUSIONS It is believed that the proposed imaging method may find its utility in advanced clinical applications wherein a ROI-based image processing and analysis is required for lesion visualization, characterization, and diagnosis.
Collapse
Affiliation(s)
- Shaojie Tang
- Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Drive, C-5018, Atlanta, Georgia 30322, USA
| | | |
Collapse
|
14
|
Abstract
The classic imaging geometry for computed tomography is for the collection of un-truncated projections and the reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it was elevated to have the status of a general imaging principle. Finally, a novel framework known as 'omni-tomography' is being developed for a grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features.
Collapse
Affiliation(s)
- Ge Wang
- Biomedical Imaging Cluster, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA.
| | | |
Collapse
|
15
|
Sen Sharma K, Holzner C, Vasilescu DM, Jin X, Narayanan S, Agah M, Hoffman EA, Yu H, Wang G. Scout-view assisted interior micro-CT. Phys Med Biol 2013; 58:4297-314. [PMID: 23732478 PMCID: PMC3732817 DOI: 10.1088/0031-9155/58/12/4297] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Micro computed tomography (micro-CT) is a widely-used imaging technique. A challenge of micro-CT is to quantitatively reconstruct a sample larger than the field-of-view (FOV) of the detector. This scenario is characterized by truncated projections and associated image artifacts. However, for such truncated scans, a low resolution scout scan with an increased FOV is frequently acquired so as to position the sample properly. This study shows that the otherwise discarded scout scans can provide sufficient additional information to uniquely and stably reconstruct the interior region of interest. Two interior reconstruction methods are designed to utilize the multi-resolution data without significant computational overhead. While most previous studies used numerically truncated global projections as interior data, this study uses truly hybrid scans where global and interior scans were carried out at different resolutions. Additionally, owing to the lack of standard interior micro-CT phantoms, we designed and fabricated novel interior micro-CT phantoms for this study to provide means of validation for our algorithms. Finally, two characteristic samples from separate studies were scanned to show the effect of our reconstructions. The presented methods show significant improvements over existing reconstruction algorithms.
Collapse
Affiliation(s)
- Kriti Sen Sharma
- Dept. of Elec. & Comp. Eng., Virginia Tech, Blacksburg, VA 24061, USA
| | | | - Dragoş M. Vasilescu
- UBC James Hogg Research Centre at the Heart & Lung Institute, St Paul’s Hospital, Vancouver, B.C., V6Z 1Y6, Canada
| | - Xin Jin
- Dept. of Eng. Phys., Tsinghua Univ., Beijing 100084, China
| | - Shree Narayanan
- Dept. of Elec. & Comp. Eng., Virginia Tech, Blacksburg, VA 24061, USA
| | - Masoud Agah
- Dept. of Elec. & Comp. Eng., Virginia Tech, Blacksburg, VA 24061, USA
| | | | - Hengyong Yu
- Biomedical Imaging Division, VT-WFU School of Biomedical Eng. & Sciences, Wake Forest Univ. Health Sciences, Winston-Salem, NC 27157, USA
| | - Ge Wang
- Biomedical Imaging Center, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| |
Collapse
|
16
|
Lee J, Stayman JW, Otake Y, Schafer S, Zbijewski W, Khanna AJ, Prince JL, Siewerdsen JH. Volume-of-change cone-beam CT for image-guided surgery. Phys Med Biol 2012; 57:4969-89. [PMID: 22801026 DOI: 10.1088/0031-9155/57/15/4969] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT as prior knowledge to accurately reconstruct the aspects of the region that have changed by the surgical procedure from only a sparse set of x-rays. The proposed methods consist of a 3D-2D registration between the prior volume and a sparse set of intraoperative x-rays, creating digitally reconstructed radiographs (DRRs) from the registered prior volume, computing difference images by subtracting DRRs from the intraoperative x-rays, a penalized likelihood reconstruction of the volume of change (VOC) from the difference images, and finally a fusion of VOC reconstruction with the prior volume to visualize the entire surgical field. When the surgical changes are local and relatively small, the VOC reconstruction involves only a small volume size and a small number of projections, allowing less computation and lower radiation dose than is needed to reconstruct the entire surgical field. We applied this approach to sacroplasty phantom data obtained from a CBCT test bench and vertebroplasty data with a fresh cadaver acquired from a C-arm CBCT system with a flat-panel detector. The VOCs were reconstructed from a varying number of images (10-66 images) and compared to the CBCT ground truth using four different metrics (mean squared error, correlation coefficient, structural similarity index and perceptual difference model). The results show promising reconstruction quality with structural similarity to the ground truth close to 1 even when only 15-20 images were used, allowing dose reduction by the factor of 10-20.
Collapse
Affiliation(s)
- Junghoon Lee
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, USA.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Lauzier PT, Tang J, Chen GH. Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm. Phys Med Biol 2012; 57:2461-76. [PMID: 22481501 PMCID: PMC3350644 DOI: 10.1088/0031-9155/57/9/2461] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
C-arm cone-beam CT could replace preoperative multi-detector CT scans in the cardiac interventional setting. However, cardiac gating results in view angle undersampling and the small size of the detector results in projection data truncation. These problems are incompatible with conventional tomographic reconstruction algorithms. In this paper, the prior image constrained compressed sensing (PICCS) reconstruction method was adapted to solve these issues. The performance of the proposed method was compared to that of FDK, FDK with extrapolated projection data (E-FDK), and total variation-based compressed sensing. A canine projection dataset acquired using a clinical C-arm imaging system supplied realistic cardiac motion and anatomy for this evaluation. Three different levels of truncation were simulated. The relative root mean squared error and the universal image quality index were used to quantify the reconstruction accuracy. Three main conclusions were reached. (1) The adapted version of the PICCS algorithm offered the highest image quality and reconstruction accuracy. (2) No meaningful variation in performance was observed when the amount of truncation was changed. (3) This study showed evidence that accurate interior tomography with an undersampled acquisition is possible for realistic objects if a prior image with minimal artifacts is available.
Collapse
Affiliation(s)
| | - Jie Tang
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Guang-Hong Chen
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
- Department of Radiology, and Radiation Oncology, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
18
|
Tang S, Yang Y, Tang X. Practical interior tomography with radial Hilbert filtering and a priori knowledge in a small round area. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2012; 20:405-422. [PMID: 23324782 PMCID: PMC4076430 DOI: 10.3233/xst-2012-00348] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
PURPOSES Interior tomography problem can be solved using the so-called differentiated backprojection-projection onto convex sets (DBP-POCS) method, which requires a priori knowledge within a small area interior to the region of interest (ROI) to be imaged. In theory, the small area wherein the a priori knowledge is required can be in any shape, but most of the existing implementations carry out the Hilbert filtering either horizontally or vertically, leading to a vertical or horizontal strip that may be across a large area in the object. In this work, we implement a practical DBP-POCS method with radial Hilbert filtering and thus the small area with the a priori knowledge can be roughly round (e.g., a sinus or ventricles among other anatomic cavities in human or animal body). We also conduct an experimental evaluation to verify the performance of this practical implementation. METHODS We specifically re-derive the reconstruction formula in the DBP-POCS fashion with radial Hilbert filtering to assure that only a small round area with the a priori knowledge be needed (namely radial DBP-POCS method henceforth). The performance of the practical DBP-POCS method with radial Hilbert filtering and a priori knowledge in a small round area is evaluated with projection data of the standard and modified Shepp-Logan phantoms simulated by computer, followed by a verification using real projection data acquired by a computed tomography (CT) scanner. RESULTS The preliminary performance study shows that, if a priori knowledge in a small round area is available, the radial DBP-POCS method can solve the interior tomography problem in a more practical way at high accuracy. CONCLUSIONS In comparison to the implementations of DBP-POCS method demanding the a priori knowledge in horizontal or vertical strip, the radial DBP-POCS method requires the a priori knowledge within a small round area only. Such a relaxed requirement on the availability of a priori knowledge can be readily met in practice, because a variety of small round areas (e.g., air-filled sinuses or fluid-filled ventricles among other anatomic cavities) exist in human or animal body. Therefore, the radial DBP-POCS method with a priori knowledge in a small round area is more feasible in clinical and preclinical practice.
Collapse
Affiliation(s)
- Shaojie Tang
- Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C5018, Atlanta, GA 30322, USA
- School of Automation, Xi’an University of Posts and Telecommunications, Xi’an, Shaanxi, 710121, China
| | - Yi Yang
- Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C5018, Atlanta, GA 30322, USA
| | - Xiangyang Tang
- Imaging and Medical Physics, Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1701 Uppergate Dr., C5018, Atlanta, GA 30322, USA
| |
Collapse
|
19
|
Schmidt TG, Pektas F. Region-of-interest material decomposition from truncated energy-resolved CT. Med Phys 2011; 38:5657-66. [PMID: 21992382 DOI: 10.1118/1.3641749] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Energy-resolved CT using photon-counting detectors has the potential to provide improved material decomposition compared to dual-kVp approaches. However, available photon-counting detectors are susceptible to pulse-pileup artifacts, especially at the periphery of the field of view (FOV) where the object attenuation is low compared to the center of the FOV. Pulse pileup may be avoided by imaging a region-of-interest (ROI) where the dynamic range is expected to be limited. This work investigated performing material decomposition and reconstructing ROI basis images from truncated energy-resolved data. METHODS A method is proposed to reconstruct images of basis functions primarily contained within the ROI, such as targeted or localized K-edge contrast agents. Material decomposition is performed independently for each ray in the sinogram, followed by filtered backprojection from the truncated data encompassing the ROI. A second method is proposed that uses a prior conventional energy-integrating image to estimate energy-resolved data outside the ROI. The measured and estimated energy-resolved data are decomposed into basis projections and merged into basis sinograms of the full FOV. Basis images of the ROI are then reconstructed through filtered backprojection. This method is most easily applied to objects that do not contain K-edge contrast agents outside the ROI. Simulations of a voxelized thorax phantom with iodine in the blood pool and a detector with five energy bins were performed. Full FOV, truncated, and truncated data merged with data estimated from the prior energy-integrating image were decomposed into Compton, photoelectric, and iodine basis functions. An empirical weighting factor was determined to blend the merged sinogram at the boundary of the truncated data. The effects of noise and misalignment in the prior image were also quantified. Basis images of the central 15 cm × 15 cm ROI containing the heart were reconstructed via filtered backprojection. Basis image accuracy was quantified relative to gold-standard basis images reconstructed from full FOV energy-resolved data. RESULTS The error in the iodine basis image reconstructed from truncated energy-resolved data without prior information was less than 1% for the central 7 cm of the 7.5-cm-radius ROI and 3% at the edge of the ROI. When the truncated and estimated basis sinograms were blended, the error was below 1% throughout the ROI for photoelectric basis images and ranged from 1% at the center of the ROI to 4% at the edge for the Compton basis image. CONCLUSIONS The density of localized K-edge contrast agents can be estimated to within 1% error using filtered back projection without prior information. For noncontrast and localized-contrast scans, ROI images of general basis functions can be reconstructed to within a few percent error using a prior energy-integrating image. The ability to perform material decomposition for a limited ROI may facilitate energy-resolved CT with available photon-counting detectors.
Collapse
Affiliation(s)
- Taly Gilat Schmidt
- Department of Biomedical Engineering, Marquette University, Milwaukee, WI 53201, USA.
| | | |
Collapse
|