Pautasso JJ, Michielsen K, Sechopoulos I. Technical note: Characterization, validation, and spectral optimization of a dedicated breast CT system for contrast-enhanced imaging. Med Phys 2024; 51:3322-3333. [PMID: 38597897 DOI: 10.1002/mp.17069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 04/01/2024] [Accepted: 04/01/2024] [Indexed: 04/11/2024] Open
Abstract
BACKGROUND The development of a new imaging modality, such as 4D dynamic contrast-enhanced dedicated breast CT (4D DCE-bCT), requires optimization of the acquisition technique, particularly within the 2D contrast-enhanced imaging modality. Given the extensive parameter space, cascade-systems analysis is commonly used for such optimization. PURPOSE To implement and validate a parallel-cascaded model for bCT, focusing on optimizing and characterizing system performance in the projection domain to enhance the quality of input data for image reconstruction. METHODS A parallel-cascaded system model of a state-of-the-art bCT system was developed and model predictions of the presampled modulation transfer function (MTF) and the normalized noise power spectrum (NNPS) were compared with empirical data collected in the projection domain. Validation was performed using the default settings of 49 kV with 1.5 mm aluminum filter and at 65 kV and 0.257 mm copper filter. A 10 mm aluminum plate was added to replicate the breast attenuation. Air kerma at the isocenter was measured at different tube current levels. Discrepancies between the measured projection domain metrics and model-predicted values were quantified using percentage error and coefficient of variation (CoV) for MTF and NNPS, respectively. The optimal filtration was for a 5 mm iodine disk detection task at 49, 55, 60, and 65 kV. The detectability index was calculated for the default aluminum filtration and for copper thicknesses ranging from 0.05 to 0.4 mm. RESULTS At 49 kV, MTF errors were +5.1% and -5.1% at 1 and 2 cycles/mm, respectively; NNPS CoV was 5.3% (min = 3.7%; max = 8.5%). At 65 kV, MTF errors were -0.8% and -3.2%; NNPS CoV was 13.1% (min = 11.4%; max = 16.9%). Air kerma output was linear, with 11.67 µGy/mA (R2 = 0.993) and 19.14 µGy/mA (R2 = 0.996) at 49 and 65 kV, respectively. For iodine detection, a 0.25 mm-thick copper filter at 65 kV was found optimal, outperforming the default technique by 90%. CONCLUSION The model accurately predicts bCT system performance, specifically in the projection domain, under varied imaging conditions, potentially contributing to the enhancement of 2D contrast-enhanced imaging in 4D DCE-bCT.
Collapse
Affiliation(s)
- Juan J Pautasso
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Koen Michielsen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Ioannis Sechopoulos
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands
- Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
- Technical Medical Centre, University of Twente, Enschede, The Netherlands
| |
Collapse
|
2
|
Wang J, Liu Y, Hu A, Wu Z, Zhang H, Li J, Qiu R. THUBreast: an open-source breast phantom generation software for x-ray imaging and dosimetry. Phys Med Biol 2024; 69:065004. [PMID: 38346343 DOI: 10.1088/1361-6560/ad2881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 02/12/2024] [Indexed: 03/08/2024]
Abstract
Objective. Establishing realistic phantoms of human anatomy is a continuing concern within virtual clinical trials of breast x-ray imaging. However, little attention has been paid to glandular distribution within these phantoms. The principal objective of this study was to develop breast phantoms considering the clinical glandular distribution.Approach. This research introduces an innovative method for integrating glandular distribution information into breast phantoms. We have developed an open-source software, THUBreast44http://github.com/true02Hydrogen/THUBreast/, which generates breast phantoms that accurately replicate both the structural texture and glandular distribution, two crucial elements in breast x-ray imaging and dosimetry. To validate the efficacy of THUBreast, we assembled three groups of breast phantoms (THUBreast, patient-based, homogeneous) for irradiation simulation and calculated the power-law exponents (β) and mean glandular dose (Dg), indicators of texture realism and radiation risk, respectively, utilizing MC-GPU.Main results. Upon the computation of theDgfor the THUBreast phantoms, it was found to be in agreement with that absorbed by the phantoms based on patients, with an average deviation of 4%. The estimates of averageDgthus obtained were on average 23% less than those computed for the homogeneous phantoms. It was observed that the homogeneous phantoms did overestimate the averageDgby 30% when compared to the phantoms based on patients. The mean value ofβfor the images of THUBreast phantoms was found to be 2.92 ± 0.08, which shows a commendable agreement with the findings of prior investigations.Significance. It is evidently clear from the results that THUBreast phantoms have a preliminary good performance in both imaging and dosimetry in terms of indicators of texture realism and glandular dose. THUBreast represents a further step towards developing a powerful toolkit for comprehensive evaluation of image quality and radiation risk.
Collapse
Affiliation(s)
- Jiahao Wang
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
- Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084, People's Republic of China
| | - Yeqi Liu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
- Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084, People's Republic of China
| | - Ankang Hu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
- Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084, People's Republic of China
| | - Zhen Wu
- Joint Institute of Tsinghua University & Nuctech Company Limited Beijing, People's Republic of China
| | - Hui Zhang
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
- Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084, People's Republic of China
| | - Junli Li
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
- Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084, People's Republic of China
| | - Rui Qiu
- Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China
- Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084, People's Republic of China
| |
Collapse
|
3
|
Monnin P, Damet J, Bosmans H, Marshall NW. Task-based detectability in anatomical background in digital mammography, digital breast tomosynthesis and synthetic mammography. Phys Med Biol 2024; 69:025017. [PMID: 38214048 DOI: 10.1088/1361-6560/ad1766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 12/20/2023] [Indexed: 01/13/2024]
Abstract
Objective.Determining the detectability of targets for the different imaging modalities in mammography in the presence of anatomical background noise is challenging. This work proposes a method to compare the image quality and detectability of targets in digital mammography (DM), digital breast tomosynthesis (DBT) and synthetic mammography.Approach. The low-frequency structured noise produced by a water phantom with acrylic spheres was used to simulate anatomical background noise for the different types of images. A method was developed to apply the non-prewhitening observer model with eye filter (NPWE) in these conditions. A homogeneous poly(methyl) methacrylate phantom with a 0.2 mm thick aluminium disc was used to calculate 2D in-plane modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta, and system detective quantum efficiency for 30, 50 and 70 mm thicknesses. The in-depth MTFs of DBT volumes were determined using a thin tungsten wire. The MTF, system NPS and anatomical NPS were used in the NPWE model to calculate the threshold gold thickness of the gold discs contained in the CDMAM phantom, which was taken as reference. Main results.The correspondence between the NPWE model and the CDMAM phantom (linear Pearson correlation 0.980) yielded a threshold detectability index that was used to determine the threshold diameter of spherical microcalcifications and masses. DBT imaging improved the detection of masses, which depended mostly on the reduction of anatomical background noise. Conversely, DM images yielded the best detection of microcalcifications.Significance.The method presented in this study was able to quantify image quality and object detectability for the different imaging modalities and levels of anatomical background noise.
Collapse
Affiliation(s)
- P Monnin
- Institute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - J Damet
- Institute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - H Bosmans
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, 3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, 3000 Leuven, Belgium
| | - N W Marshall
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, 3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, 3000 Leuven, Belgium
| |
Collapse
|
4
|
Tanguay J, Lalonde R, Bjarnason TA, Yang CYJ. Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography. Phys Med Biol 2019; 64:215002. [PMID: 31470440 DOI: 10.1088/1361-6560/ab3fcd] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energy (DE) DM. Our mathematical framework unifies and generalizes existing approaches. We compared mathematical predictions directly with empirical measurements of the anatomic noise power spectrum of the CIRS BR3D structured breast phantom using two clinical mammography systems and four beam qualities. Our simulation and experimental results showed agreement with mathematical predictions. As a demonstration of utility, we used our mathematical framework in a theoretical spectral optimization of DM for the task of detecting breast masses. Our theoretical optimization showed that the optimal tube voltage for DM may be higher than that based on predictions that do not account for anatomic noise, in agreement with recent theoretical findings. Additionally, our theoretical optimization predicts that filtering tungsten-anode x-ray spectra with rhodium has little influence on lesion detectability, in contrast with previous findings. The mathematical methods validated in this work can be incorporated easily into cascaded systems analysis of breast imaging systems and will be useful when optimizating novel techniques for x-ray-based imaging of the breast.
Collapse
Affiliation(s)
- Jesse Tanguay
- Department of Physics, Ryerson University, Toronto, Ontario, Canada. Author to whom correspondence should be addressed
| | | | | | | |
Collapse
|
5
|
Wessam R, Gomaa MMM, Fouad MA, Mokhtar SM, Tohamey YM. Added value of contrast-enhanced mammography in assessment of breast asymmetries. Br J Radiol 2019; 92:20180245. [PMID: 30932687 DOI: 10.1259/bjr.20180245] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE To evaluate the clinical performance of contrast-enhanced spectral mammography (CESM) on asymmetries detected on a mammogram (MG). METHODS This study was approved by the Scientific Research Review Board of the Radiology Department, and waiver of informed consent was applied for the uses of data of the included cases. The study included 125 female patients,33 (26.4%) who presented for screening and 92 (73.6%) who presented for a diagnostic MG. All had breast asymmetries on MG. Ultrasound examination and CESM using dual-energy acquisitions were performed for all patients. RESULTS In all, 88/125 (70.4%) females had focal asymmetry (seen in two views and occupying less than a quadrant), 26/125 (20.8%) had global asymmetry (occupying more than one quadrant), 10/125 (8%) had asymmetry (seen in a single view and occupying less than a quadrant), and 1/125 had developing asymmetry (0.8%) (not present in the previous MG). Malignant lesions represented 91 cases, benign lesions represented 30 cases, and 4 cases were high-risk lesions. CESM sensitivity was 100% (v s 97.8 % for sono-mammography), specificity was 55.88% (v s 81.8% for sono-mammography), and the positive- and negative-predictive values were 85.85 and 100% (v s 93.7 and 93% for sono-mammography respectively) . CONCLUSION In our study, we conclude that focal and global asymmetries with other suspicious mammographic findings were statistically significant for malignancy and CESM played an important role in delineating tumor size and extension. Any non-enhancing asymmetrical density correlated with a benign pathology, if not associated with other suspicious imaging findings. ADVANCES IN KNOWLEDGE: Our study is the first to explore the added value of CESM to asymmetries detected in screening and diagnostic mammography.
Collapse
Affiliation(s)
- Rasha Wessam
- 1 Department of Radiology Faculty of Medicine, Kasr El Aini hospital, Cairo University , Egypt
| | | | - Mona Ahmed Fouad
- 1 Department of Radiology Faculty of Medicine, Kasr El Aini hospital, Cairo University , Egypt
| | - Sherif Mohamed Mokhtar
- 3 Department of Surgery Faculty of Medicine, Kasr El Aini hospital Cairo University , Egypt
| | - Yasmin Mounir Tohamey
- 1 Department of Radiology Faculty of Medicine, Kasr El Aini hospital, Cairo University , Egypt
| |
Collapse
|
6
|
Huang H, Scaduto DA, Liu C, Yang J, Zhu C, Rinaldi K, Eisenberg J, Liu J, Hoernig M, Wicklein J, Vogt S, Mertelmeier T, Fisher PR, Zhao W. Comparison of contrast-enhanced digital mammography and contrast-enhanced digital breast tomosynthesis for lesion assessment. J Med Imaging (Bellingham) 2019; 6:031407. [PMID: 30766895 DOI: 10.1117/1.jmi.6.3.031407] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 01/10/2019] [Indexed: 01/22/2023] Open
Abstract
Contrast-enhanced digital mammography (CEDM) reveals neovasculature of breast lesions in a two-dimensional contrast enhancement map. Contrast-enhanced digital breast tomosynthesis (CEDBT) provides contrast enhancement in three dimensions, which may improve lesion characterization and localization. We aim to compare CEDM and CEDBT for lesion assessment. Women with breast imaging-reporting and data system 4 or 5 suspicious breast lesion(s) were recruited in our study and were imaged with CEDM and CEDBT in succession under one breast compression. Two radiologists assessed CEDM and CEDBT with both images displayed side-by-side and compared (1) contrast enhancement of lesions and (2) lesion margin using a five-point scale ranging from - 2 (CEDM much better) to + 2 (CEDBT much better). Biopsy identified 19 malignant lesions with contrast enhancement. Our results show that CEDBT provides better lesion margins than CEDM with limited reduction in contrast enhancement. CEDBT delivers less radiation dose compared to CEDM + DBT. Synthetic CEDM can be generated from CEDBT data and provides lesion contrast enhancement comparable to CEDM. CEDBT has potential for clinical applications, such as treatment response monitoring and guidance for biopsy.
Collapse
Affiliation(s)
- Hailiang Huang
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| | - David A Scaduto
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| | - Chunling Liu
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| | - Jie Yang
- Stony Brook Medicine, Department of Family, Population and Preventive Medicine, Stony Brook, New York, United States
| | - Chencan Zhu
- Stony Brook University, Department of Applied Mathematics and Statistics, Stony Brook, New York, United States
| | - Kim Rinaldi
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| | - Jason Eisenberg
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| | - Jingxuan Liu
- Stony Brook Medicine, Department of Pathology, Stony Brook, New York, United States
| | | | | | - Sebastian Vogt
- Siemens Medical Solutions USA Inc., Monument, Colorado, United States
| | | | - Paul R Fisher
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| | - Wei Zhao
- Stony Brook Medicine, Department of Radiology, Stony Brook, New York, United States
| |
Collapse
|
7
|
Makeev A, Glick SJ. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:2417-2423. [PMID: 28783629 DOI: 10.1109/tmi.2017.2735302] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.
Collapse
|
8
|
Hu YH, Myronakis M, Rottmann J, Wang A, Morf D, Shedlock D, Baturin P, Star-Lack J, Berbeco R. A novel method for quantification of beam's-eye-view tumor tracking performance. Med Phys 2017; 44:5650-5659. [PMID: 28887836 DOI: 10.1002/mp.12572] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Revised: 08/21/2017] [Accepted: 08/31/2017] [Indexed: 12/12/2022] Open
Abstract
PURPOSE In-treatment imaging using an electronic portal imaging device (EPID) can be used to confirm patient and tumor positioning. Real-time tumor tracking performance using current digital megavolt (MV) imagers is hindered by poor image quality. Novel EPID designs may help to improve quantum noise response, while also preserving the high spatial resolution of the current clinical detector. Recently investigated EPID design improvements include but are not limited to multi-layer imager (MLI) architecture, thick crystalline and amorphous scintillators, and phosphor pixilation and focusing. The goal of the present study was to provide a method of quantitating improvement in tracking performance as well as to reveal the physical underpinnings of detector design that impact tracking quality. The study employs a generalizable ideal observer methodology for the quantification of tumor tracking performance. The analysis is applied to study both the effect of increasing scintillator thickness on a standard, single-layer imager (SLI) design as well as the effect of MLI architecture on tracking performance. METHODS The present study uses the ideal observer signal-to-noise ratio (d') as a surrogate for tracking performance. We employ functions which model clinically relevant tasks and generalized frequency-domain imaging metrics to connect image quality with tumor tracking. A detection task for relevant Cartesian shapes (i.e., spheres and cylinders) was used to quantitate trackability of cases employing fiducial markers. Automated lung tumor tracking algorithms often leverage the differences in benign and malignant lung tissue textures. These types of algorithms (e.g., soft-tissue localization - STiL) were simulated by designing a discrimination task, which quantifies the differentiation of tissue textures, measured experimentally and fit as a power-law in trend (with exponent β) using a cohort of MV images of patient lungs. The modeled MTF and NPS were used to investigate the effect of scintillator thickness and MLI architecture on tumor tracking performance. RESULTS Quantification of MV images of lung tissue as an inverse power-law with respect to frequency yields exponent values of β = 3.11 and 3.29 for benign and malignant tissues, respectively. Tracking performance with and without fiducials was found to be generally limited by quantum noise, a factor dominated by quantum detective efficiency (QDE). For generic SLI construction, increasing the scintillator thickness (gadolinium oxysulfide - GOS) from a standard 290 μm to 1720 μm reduces noise to about 10%. However, 81% of this reduction is appreciated between 290 and 1000 μm. In comparing MLI and SLI detectors of equivalent individual GOS layer thickness, the improvement in noise is equal to the number of layers in the detector (i.e., 4) with almost no difference in MTF. Further, improvement in tracking performance was slightly less than the square-root of the reduction in noise, approximately 84-90%. In comparing an MLI detector with an SLI with a GOS scintillator of equivalent total thickness, improvement in object detectability is approximately 34-39%. CONCLUSIONS We have presented a novel method for quantification of tumor tracking quality and have applied this model to evaluate the performance of SLI and MLI EPID designs. We showed that improved tracking quality is primarily limited by improvements in NPS. When compared to very thick scintillator SLI, employing MLI architecture exhibits the same gains in QDE, but by mitigating the effect of optical Swank noise, results in more dramatic improvements in tracking performance.
Collapse
Affiliation(s)
- Yue-Houng Hu
- Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, 75 Francis St, ASB1 L2, Boston, MA, 02115, USA
| | - Marios Myronakis
- Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, 75 Francis St, ASB1 L2, Boston, MA, 02115, USA
| | - Joerg Rottmann
- Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, 75 Francis St, ASB1 L2, Boston, MA, 02115, USA
| | - Adam Wang
- Varian Medical Systems, 3100 Hansen Way, Palo Alto, CA, 94304, USA
| | - Daniel Morf
- Varian Medical Systems, Taefernstrasse 5, Baden-Daettwil, 5405, Switzerland
| | - Daniel Shedlock
- Varian Medical Systems, 3100 Hansen Way, Palo Alto, CA, 94304, USA
| | - Paul Baturin
- Varian Medical Systems, 3100 Hansen Way, Palo Alto, CA, 94304, USA
| | - Josh Star-Lack
- Varian Medical Systems, 3100 Hansen Way, Palo Alto, CA, 94304, USA
| | - Ross Berbeco
- Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women's Hospital, Dana-Farber Cancer Institute and Harvard Medical School, 75 Francis St, ASB1 L2, Boston, MA, 02115, USA
| |
Collapse
|
9
|
Pani S, Saifuddin SC, Ferreira FIM, Henthorn N, Seller P, Sellin PJ, Stratmann P, Veale MC, Wilson MD, Cernik RJ. High Energy Resolution Hyperspectral X-Ray Imaging for Low-Dose Contrast-Enhanced Digital Mammography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1784-1795. [PMID: 28541197 DOI: 10.1109/tmi.2017.2706065] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Contrast-enhanced digital mammography (CEDM) is an alternative to conventional X-ray mammography for imaging dense breasts. However, conventional approaches to CEDM require a double exposure of the patient, implying higher dose, and risk of incorrect image registration due to motion artifacts. A novel approach is presented, based on hyperspectral imaging, where a detector combining positional and high-resolution spectral information (in this case based on Cadmium Telluride) is used. This allows simultaneous acquisition of the two images required for CEDM. The approach was tested on a custom breast-equivalent phantom containing iodinated contrast agent (Niopam 150®). Two algorithms were used to obtain images of the contrast agent distribution: K-edge subtraction (KES), providing images of the distribution of the contrast agent with the background structures removed, and a dual-energy (DE) algorithm, providing an iodine-equivalent image and a water-equivalent image. The high energy resolution of the detector allowed the selection of two close-by energies, maximising the signal in KES images, and enhancing the visibility of details with the low surface concentration of contrast agent. DE performed consistently better than KES in terms of contrast-to-noise ratio of the details; moreover, it allowed a correct reconstruction of the surface concentration of the contrast agent in the iodine image. Comparison with CEDM with a conventional detector proved the superior performance of hyperspectral CEDM in terms of the image quality/dose tradeoff.
Collapse
|
10
|
Elangovan P, Mackenzie A, Dance DR, Young KC, Cooke V, Wilkinson L, Given-Wilson RM, Wallis MG, Wells K. Design and validation of realistic breast models for use in multiple alternative forced choice virtual clinical trials. Phys Med Biol 2017; 62:2778-2794. [PMID: 28291738 DOI: 10.1088/1361-6560/aa622c] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A novel method has been developed for generating quasi-realistic voxel phantoms which simulate the compressed breast in mammography and digital breast tomosynthesis (DBT). The models are suitable for use in virtual clinical trials requiring realistic anatomy which use the multiple alternative forced choice (AFC) paradigm and patches from the complete breast image. The breast models are produced by extracting features of breast tissue components from DBT clinical images including skin, adipose and fibro-glandular tissue, blood vessels and Cooper's ligaments. A range of different breast models can then be generated by combining these components. Visual realism was validated using a receiver operating characteristic (ROC) study of patches from simulated images calculated using the breast models and from real patient images. Quantitative analysis was undertaken using fractal dimension and power spectrum analysis. The average areas under the ROC curves for 2D and DBT images were 0.51 ± 0.06 and 0.54 ± 0.09 demonstrating that simulated and real images were statistically indistinguishable by expert breast readers (7 observers); errors represented as one standard error of the mean. The average fractal dimensions (2D, DBT) for real and simulated images were (2.72 ± 0.01, 2.75 ± 0.01) and (2.77 ± 0.03, 2.82 ± 0.04) respectively; errors represented as one standard error of the mean. Excellent agreement was found between power spectrum curves of real and simulated images, with average β values (2D, DBT) of (3.10 ± 0.17, 3.21 ± 0.11) and (3.01 ± 0.32, 3.19 ± 0.07) respectively; errors represented as one standard error of the mean. These results demonstrate that radiological images of these breast models realistically represent the complexity of real breast structures and can be used to simulate patches from mammograms and DBT images that are indistinguishable from patches from the corresponding real breast images. The method can generate about 500 radiological patches (~30 mm × 30 mm) per day for AFC experiments on a single workstation. This is the first study to quantitatively validate the realism of simulated radiological breast images using direct blinded comparison with real data via the ROC paradigm with expert breast readers.
Collapse
Affiliation(s)
- Premkumar Elangovan
- Medical Imaging Group, Centre for Vision, Speech, and Signal Processing, University of Surrey, Guildford, GU2 7XH, United Kingdom. National Coordination Centre for the Physics of Mammography (NCCPM), Royal Surrey County Hospital, Guildford, GU2 7XX, United Kingdom
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Glick SJ, Makeev A. Investigation of x-ray spectra for iodinated contrast-enhanced dedicated breast CT. J Med Imaging (Bellingham) 2017; 4:013504. [PMID: 28149923 DOI: 10.1117/1.jmi.4.1.013504] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 01/04/2017] [Indexed: 12/27/2022] Open
Abstract
Screening for breast cancer with mammography has been very successful, resulting in part to a reduction of breast cancer mortality by approximately 39% since 1990. However, mammography still has limitations in performance, especially for women with dense breast tissue. Iodinated contrast-enhanced, dedicated breast CT (BCT) has been proposed to improve lesion analysis and the accuracy of diagnostic workup for patients suspected of having breast cancer. A mathematical analysis to explore the use of various x-ray filters for iodinated contrast-enhanced BCT is presented. To assess task-based performance, the ideal linear observer signal-to-noise ratio (SNR) is used as a figure-of-merit under the assumptions of a linear, shift-invariant imaging system. To estimate signal and noise propagation through the BCT detector, a parallel-cascade model was used. The lesion model was embedded into a structured background and included a realistic level of iodine uptake. SNR was computed for 84,000 different exposure settings by varying the kV setting, x-ray filter materials and thickness, breast size, and composition and radiation dose. It is shown that some x-ray filter material/thickness combinations can provide up to 75% improvement in the linear ideal observer SNR over a conventionally used x-ray filter for BCT. This improvement in SNR can be traded off for substantial reductions in mean glandular dose.
Collapse
Affiliation(s)
- Stephen J Glick
- US Food and Drug Administration , Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| | - Andrey Makeev
- US Food and Drug Administration , Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| |
Collapse
|
12
|
Hu YH, Scaduto DA, Zhao W. Optimization of contrast-enhanced breast imaging: Analysis using a cascaded linear system model. Med Phys 2017; 44:43-56. [PMID: 28044312 DOI: 10.1002/mp.12004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 11/03/2016] [Accepted: 11/04/2016] [Indexed: 12/31/2022] Open
Abstract
PURPOSE Contrast-enhanced (CE) breast imaging involves the injection contrast agents (i.e., iodine) to increase conspicuity of malignant lesions. CE imaging may be used in conjunction with digital mammography (DM) or digital breast tomosynthesis (DBT) and has shown promise in improving diagnostic specificity. Both CE-DM and CE-DBT techniques require optimization as clinical diagnostic tools. Physical factors including x-ray spectra, subtraction technique, and the signal from iodine contrast, must be considered to provide the greatest object detectability and image quality. We developed a cascaded linear system model (CLSM) for the optimization of CE-DM and CE-DBT employing dual energy (DE) subtraction or temporal (TE) subtraction. METHODS We have previously developed a CLSM for DBT implemented with an a-Se flat panel imager (FPI) and filtered backprojection (FBP) reconstruction algorithm. The model is used to track image quality metrics - modulation transfer function (MTF) and noise power spectrum (NPS) - at each stage of the imaging chain. In this study, the CLSM is extended for CE breast imaging. The effect of x-ray spectrum (varied by changing tube potential and the filter) and DE and TE subtraction techniques on breast structural noise was measured was studied and included as a deterministic source of noise in the CLSM. From the two-dimensional (2D) and three-dimensional (3D) MTF and NPS, the ideal observer signal-to-noise ratio (SNR), also known as the detectability index (d'), may be calculated. Using d' as a FOM, we discuss the optimization of CE imaging for the task of iodinated contrast object detection within structured backgrounds. RESULTS Increasing x-ray energy was determined to decrease the magnitude of structural noise and not its correlation. By performing DE subtraction, the magnitude of the structural noise was further reduced at the expense of increased stochastic (quantum and electronic) noise. TE subtraction exhibited essentially no residual structural noise at the expense of increased quantum noise, even over that of the DE case. For DE subtraction, optimization of dose weighting to the HE view (fh ) results in the minimization of quantum noise. Both subtraction weighting factor (wSub ) and the iodine contrast signal were dependent on the LE and HE x-ray spectra. To best detect a 5 mm Gaussian lesion with 5 mg/ml of iodine within a 4 cm thick breast, it was found that the high energy (HE) view should be acquired with a tube potential of 47 kVp (W/Ti spectrum) and the low energy (LE) view with a potential of 23 kVp (W/Rh spectrum). Due to the complete removal of structural noise, TE subtraction produced much higher d' than DE subtraction both as a function of mean glandular dose and iodine concentration. CONCLUSIONS We have shown the effect of increasing x-ray energy as well as projection domain subtraction on breast structural noise. Further, we have exhibited the utility of the CLSM for DE and TE subtraction CE imaging in the optimization of imaging parameters such as x-ray energy, fh , and wSub as well as guiding the understanding of their effects on image contrast and noise.
Collapse
Affiliation(s)
- Yue-Houng Hu
- Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, NY, 11794-8460, USA
| | - David A Scaduto
- Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, NY, 11794-8460, USA
| | - Wei Zhao
- Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, NY, 11794-8460, USA
| |
Collapse
|
13
|
Contillo A, Di Domenico G, Cardarelli P, Gambaccini M, Taibi A. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Noise minimization. Med Phys 2016; 43:3080-3089. [DOI: 10.1118/1.4951730] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
14
|
Hu YH, Zhao W. The effect of amorphous selenium detector thickness on dual-energy digital breast imaging. Med Phys 2015; 41:111904. [PMID: 25370637 DOI: 10.1118/1.4897244] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
PURPOSE Contrast enhanced (CE) imaging techniques for both planar digital mammography (DM) and three-dimensional (3D) digital breast tomosynthesis (DBT) applications requires x-ray photon energies higher than the k-edge of iodine (33.2 keV). As a result, x-ray tube potentials much higher (>40 kVp) than those typical for screening mammography must be utilized. Amorphous selenium (a-Se) based direct conversion flat-panel imagers (FPI) have been widely used in DM and DBT imaging systems. The a-Se layer is typically 200 μm thick with quantum detective efficiency (QDE) >87% for x-ray energies below 26 keV. However, QDE decreases substantially above this energy. To improve the object detectability of either CE-DM or CE-DBT, it may be advantageous to increase the thickness (dSe) of the a-Se layer. Increasing the dSe will improve the detective quantum efficiency (DQE) at the higher energies used in CE imaging. However, because most DBT systems are designed with partially isocentric geometries, where the gantry moves about a stationary detector, the oblique entry of x-rays will introduce additional blur to the system. The present investigation quantifies the effect of a-Se thickness on imaging performance for both CE-DM and CE-DBT, discussing the effects of improving photon absorption and blurring from oblique entry of x-rays. METHODS In this paper, a cascaded linear system model (CLSM) was used to investigate the effect of dSe on the imaging performance (i.e., MTF, NPS, and DQE) of FPI in CE-DM and CE-DBT. The results from the model are used to calculate the ideal observer signal-to-noise ratio, d', which is used as a figure-of-merit to determine the total effect of increasing dSe for CE-DM and CE-DBT. RESULTS The results of the CLSM show that increasing dSe causes a substantial increase in QDE at the high energies used in CE-DM. However, at the oblique projection angles used in DBT, the increased length of penetration through a-Se introduces additional image blur. The reduced MTF and DQE at high spatial frequencies lead to reduced two-dimensional d'. These losses in projection image resolution may subsequently result in a decrease in the 3D d', but the degree of which is largely dependent on the DBT reconstruction algorithm. For a filtered backprojection (FBP) algorithm with spectral apodization and slice-thickness filters, which dominate the blur for reconstructed images at oblique angles, the effect of oblique entry of x-rays on 3D d' is minimal. Thus, increasing dSe results in an improvement in d' for both CE-DM and CE-DBT with typical FBP reconstruction parameters. CONCLUSIONS Increased dSe improves CE breast imaging performance by increasing QDE of detectors at higher energies, e.g., 49 kVp. Although there is additional blur in the oblique angled projections of a DBT scan, the overall 3D d' for DBT is not degraded because the dominant source blur at these angles results from the reconstruction filters of the employed FBP algorithm.
Collapse
Affiliation(s)
- Yue-Houng Hu
- Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, New York 11794-8460
| | - Wei Zhao
- Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, New York 11794-8460
| |
Collapse
|
15
|
Mohamed Kamal R, Hussien Helal M, Wessam R, Mahmoud Mansour S, Godda I, Alieldin N. Contrast-enhanced spectral mammography: Impact of the qualitative morphology descriptors on the diagnosis of breast lesions. Eur J Radiol 2015; 84:1049-55. [PMID: 25818731 DOI: 10.1016/j.ejrad.2015.03.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2014] [Revised: 01/13/2015] [Accepted: 03/03/2015] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To analyze the morphology and enhancement characteristics of breast lesions on contrast-enhanced spectral mammography (CESM) and to assess their impact on the differentiation between benign and malignant lesions. MATERIALS AND METHOD This ethics committee approved study included 168 consecutive patients with 211 breast lesions over 18 months. Lesions classified as non-enhancing and enhancing and then the latter group was subdivided into mass and non-mass. Mass lesions descriptors included: shape, margins, pattern and degree of internal enhancement. Non-mass lesions descriptors included: distribution, pattern and degree of internal enhancement. The impact of each descriptor on diagnosis individually assessed using Chi test and the validity compared in both benign and malignant lesions. The overall performance of CESM were also calculated. RESULTS The study included 102 benign (48.3%) and 109 malignant (51.7%) lesions. Enhancement was encountered in 145/211 (68.7%) lesions. They further classified into enhancing mass (99/145, 68.3%) and non-mass lesions (46/145, 31.7%). Contrast uptake was significantly more frequent in malignant breast lesions (p value ≤ 0.001). Irregular mass lesions with intense and heterogeneous enhancement patterns correlated with a malignant pathology (p value ≤ 0.001). CESM showed an overall sensitivity of 88.99% and specificity of 83.33%. The positive and negative likelihood ratios were 5.34 and 0.13 respectively. CONCLUSION The assessment of the morphology and enhancement characteristics of breast lesions on CESM enhances the performance of digital mammography in the differentiation between benign and malignant breast lesions.
Collapse
Affiliation(s)
- Rasha Mohamed Kamal
- Radiology Department (Women's Imaging unit), Kasr ElAiny Hospital, Cairo University, Egypt
| | - Maha Hussien Helal
- Radiology Department (Breast Imaging unit), National Cancer Institute, Cairo University, Egypt
| | - Rasha Wessam
- Radiology Department (Women's Imaging unit), Kasr ElAiny Hospital, Cairo University, Egypt
| | - Sahar Mahmoud Mansour
- Radiology Department (Breast Imaging unit), National Cancer Institute, Cairo University, Egypt.
| | - Iman Godda
- Pathology Department, National Cancer Institute, Cairo University, Egypt
| | - Nelly Alieldin
- Statistics Department, National Cancer Institute, Cairo University, Egypt
| |
Collapse
|
16
|
Bouwman RW, van Engen RE, Young KC, Veldkamp WJH, Dance DR. Dose assessment in contrast enhanced digital mammography using simple phantoms simulating standard model breasts. Phys Med Biol 2015; 60:N1-7. [PMID: 25500435 DOI: 10.1088/0031-9155/60/1/n1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE) slabs are used to simulate standard model breasts for the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT). These phantoms are optimized for the energy spectra used in DM and DBT, which normally have a lower average energy than used in contrast enhanced digital mammography (CEDM). In this study we have investigated whether these phantoms can be used for the evaluation of AGD with the high energy x-ray spectra used in CEDM. For this purpose the calculated values of the incident air kerma for dosimetry phantoms and standard model breasts were compared in a zero degree projection with the use of an anti scatter grid. It was found that the difference in incident air kerma compared to standard model breasts ranges between -10% to +4% for PMMA slabs and between 6% and 15% for PMMA-PE slabs. The estimated systematic error in the measured AGD for both sets of phantoms were considered to be sufficiently small for the evaluation of AGD in quality control procedures for CEDM. However, the systematic error can be substantial if AGD values from different phantoms are compared.
Collapse
Affiliation(s)
- R W Bouwman
- Dutch reference centre for screening, Radboud University Nijmegen Medical Centre (LRCB), Weg door Jonkerbos 90, 6532 SZ Nijmegen, The Netherlands
| | | | | | | | | |
Collapse
|
17
|
Dance DR, Young KC. Estimation of mean glandular dose for contrast enhanced digital mammography: factors for use with the UK, European and IAEA breast dosimetry protocols. Phys Med Biol 2014; 59:2127-37. [PMID: 24699200 DOI: 10.1088/0031-9155/59/9/2127] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The UK, European and IAEA protocols for breast dosimetry in mammography use tabulations of conversion factors, which relate measurements of incident air kerma to the mean glandular dose to the breast. To supplement the existing tabulations, a Monte Carlo computer program has been used to calculate conversion factors for the high-energy spectra used for contrast enhanced digital mammography. The calculations were made for the x-ray spectra from a tungsten target (tube voltage range 40-50 kV) filtered by 0.28, 0.30 and 0.32 mm of copper, and from molybdenum and rhodium targets (tube voltage range 40-49 kV), each filtered by 0.30 mm of copper. The g-factors for all of these spectra were plotted for each breast thickness as a function of half value layer (HVL) and were found to lie on smooth curves within 0.3%. These reflect the fact that the characteristic x-rays present in the spectra from molybdenum and rhodium are heavily filtered and all the spectra are essentially Bremsstrahlung. As a consequence, the s-factor previously used in the dosimetry protocols to adjust for different target/filter combinations can be taken as unity for all of the spectra considered. Tables of g-factors and c-factors are provided for breast thicknesses in the range 20-110 mm and HVLs in the range 2.4-3.6 mm of aluminium. The tables of c-factors are given for breast glandularities in the range 0.1%-100% and for typical glandularities for women in the age bands 40-49 and 50-64 attending the UK national breast screening programme.
Collapse
Affiliation(s)
- D R Dance
- NCCPM, Medical Physics Department, Royal Surrey County Hospital, Guildford GU2 7XX, UK. Department of Physics, University of Surrey, Guildford GU2 7XH, UK
| | | |
Collapse
|
18
|
Hill ML, Mainprize JG, Carton AK, Saab-Puong S, Iordache R, Muller S, Jong RA, Dromain C, Yaffe MJ. Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging. Med Phys 2013; 40:081907. [DOI: 10.1118/1.4812681] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
|