1
|
Arslan NO, Luo X. Assessing the Relationship Between Pitch Perception and Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2022; 23:875-887. [PMID: 36329369 PMCID: PMC9789247 DOI: 10.1007/s10162-022-00876-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
Various neural health estimates have been shown to indicate the density of spiral ganglion neurons in animal and modeling studies of cochlear implants (CIs). However, when applied to human CI users, these neural health estimates based on psychophysical and electrophysiological measures are not consistently correlated with each other or with the speech recognition performance. This study investigated whether the neural health estimates have stronger correlations with the temporal and place pitch sensitivity than with the speech recognition performance. On five electrodes in 12 tested ears of eight adult CI users, polarity effect (PE), multipulse integration (MPI), and interphase gap (IPG) effect on the amplitude growth function (AGF) of electrically evoked compound action potential (ECAP) were measured to estimate neural health, while thresholds of amplitude modulation frequency ranking (AMFR) and virtual channel ranking (VCR) were measured to indicate temporal and place pitch sensitivity. AzBio sentence recognition in noise was measured using the clinical CI processor for each ear. The results showed significantly poorer AMFR and VCR thresholds on the basal electrodes than on the apical and middle electrodes. Across ears and electrodes, only the IPG offset effect on ECAP AGF had a nearly significant negative correlation with the VCR threshold after removing the outliers. No significant across-ear correlations were found between the mean neural health estimates, mean pitch-ranking thresholds, and AzBio sentence recognition score. This study suggests that the central axon demyelination reflected by the IPG offset effect may be important for the place pitch sensitivity of CI users and that the IPG offset effect may be used to predict the perceptual resolution of virtual channels for CI programming.
Collapse
Affiliation(s)
- Niyazi O. Arslan
- Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, 975 S. Myrtle Av., Tempe, AZ 85287 USA
| | - Xin Luo
- Program of Speech and Hearing Science, College of Health Solutions, Arizona State University, 975 S. Myrtle Av., Tempe, AZ 85287 USA
| |
Collapse
|
2
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|
3
|
Zhou N, Zhu Z, Dong L, Galvin J. Sensitivity to Pulse Phase Duration as a Marker of Neural Health Across Cochlear Implant Recipients and Electrodes. J Assoc Res Otolaryngol 2021; 22:177-192. [PMID: 33559041 PMCID: PMC7943680 DOI: 10.1007/s10162-021-00784-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 01/03/2021] [Indexed: 11/19/2022] Open
Abstract
In cochlear implants, loudness has been shown to grow more slowly with increasing pulse phase duration (PPD) than with pulse amplitude (PA), possibly due to “leaky” charge integration. This leakiness has been recently quantified in terms of “charge integration efficiency,” defined as the log difference between the PPD dynamic range and PA dynamic range (both expressed in charge units), relative to a common threshold anchor. Such leakiness may differ across electrodes and/or test ears, and may reflect underlying neural health. In this study, we examined the across-site variation of charge integration in recipients of Cochlear© devices. PPD and PA dynamic ranges were measured relative to two threshold anchors with either a 25- or 50-microsecond PPD. Strength-duration functions, previously shown to relate to survival of spiral ganglion cells and peripheral processes, were compared to charge integration efficiency on selected electrodes. Results showed no significant or systematic relationship between the across-site variation in charge integration efficiency and electrode position or threshold levels. Charge integration efficiency was poorer with the 50-μs threshold anchor, suggesting that greater leakiness was associated with larger PPD dynamic ranges. Poorer and more variable charge integration efficiency across electrodes was associated with longer duration of any hearing loss, consistent with the idea that poor integration is related to neural degeneration. More variable integration efficiency was also associated with poorer speech recognition performance across test ears. The slopes of the strength-duration functions at maximum acceptable loudness were significantly correlated with charge integration efficiency. However, the strength-duration slopes were not predictive of duration of any hearing loss or speech recognition performance in our participants. As such, charge integration efficiency may be a better candidate to measure leakiness in neural populations across the electrode array, as well as the general health of the auditory nerve in human cochlear implant recipients.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - Zhen Zhu
- Department of Engineering, East Carolina University, Greenville, NC, 27834, USA
| | - Lixue Dong
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA
| | - John Galvin
- House Ear Institute, 2100 W. Third St., Suite 101, Los Angeles, CA, 90057, USA.
| |
Collapse
|
4
|
Bissmeyer SRS, Hossain S, Goldsworthy RL. Perceptual learning of pitch provided by cochlear implant stimulation rate. PLoS One 2020; 15:e0242842. [PMID: 33270735 PMCID: PMC7714175 DOI: 10.1371/journal.pone.0242842] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 11/10/2020] [Indexed: 11/19/2022] Open
Abstract
Cochlear implant users hear pitch evoked by stimulation rate, but discrimination diminishes for rates above 300 Hz. This upper limit on rate pitch is surprising given the remarkable and specialized ability of the auditory nerve to respond synchronously to stimulation rates at least as high as 3 kHz and arguably as high as 10 kHz. Sensitivity to stimulation rate as a pitch cue varies widely across cochlear implant users and can be improved with training. The present study examines individual differences and perceptual learning of stimulation rate as a cue for pitch ranking. Adult cochlear implant users participated in electrode psychophysics that involved testing once per week for three weeks. Stimulation pulse rate discrimination was measured in bipolar and monopolar configurations for apical and basal electrodes. Base stimulation rates between 100 and 800 Hz were examined. Individual differences were quantified using psychophysically derived metrics of spatial tuning and temporal integration. This study examined distribution of measures across subjects, predictive power of psychophysically derived metrics of spatial tuning and temporal integration, and the effect of training on rate discrimination thresholds. Psychophysical metrics of spatial tuning and temporal integration were not predictive of stimulation rate discrimination, but discrimination thresholds improved at lower frequencies with training. Since most clinical devices do not use variable stimulation rates, it is unknown to what extent recipients may learn to use stimulation rate cues if provided in a clear and consistent manner.
Collapse
Affiliation(s)
- Susan R. S. Bissmeyer
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, United States of America
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| | - Shaikat Hossain
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| | - Raymond L. Goldsworthy
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, United States of America
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| |
Collapse
|
5
|
Lamping W, Deeks JM, Marozeau J, Carlyon RP. The Effect of Phantom Stimulation and Pseudomonophasic Pulse Shapes on Pitch Perception by Cochlear Implant Listeners. J Assoc Res Otolaryngol 2020; 21:511-526. [PMID: 32804337 PMCID: PMC7644600 DOI: 10.1007/s10162-020-00768-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 07/31/2020] [Indexed: 01/04/2023] Open
Abstract
It has been suggested that a specialized high-temporal-acuity brainstem pathway can be activated by stimulating more apically in the cochlea than is achieved by cochlear implants (CIs) when programmed with contemporary clinical settings. We performed multiple experiments to test the effect on pitch perception of phantom stimulation and asymmetric current pulses, both supposedly stimulating beyond the most apical electrode of a CI. The two stimulus types were generated using a bipolar electrode pair, composed of the most apical electrode of the array and a neighboring, more basal electrode. Experiment 1 used a pitch-ranking procedure where neural excitation was shifted apically or basally using so-called phantom stimulation. No benefit of apical phantom stimulation was found on the highest rate up to which pitch ranks increased (upper limit), nor on the slopes of the pitch-ranking function above 300 pulses per second (pps). Experiment 2 used the same procedure to study the effects of apical pseudomonophasic pulses, where the locus of excitation was manipulated by changing stimulus polarity. A benefit of apical stimulation was obtained for the slopes above 300 pps. Experiment 3 used an adaptive rate discrimination procedure and found a small but significant benefit of both types of apical stimulation. Overall, the results show some benefit for apical stimulation on temporal pitch processing at high pulse rates but reveal that the effect is smaller and more variable across listeners than suggested by previous research. The results also provide some indication that the benefit of apical stimulation may decline over time since implantation.
Collapse
Affiliation(s)
- Wiebke Lamping
- Hearing Systems Section, Department of Health Technology, Technical University of Denmark, DK-2800, Kgs. Lyngby, Denmark.
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK.
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0SZ, UK.
| | - John M Deeks
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Jeremy Marozeau
- Hearing Systems Section, Department of Health Technology, Technical University of Denmark, DK-2800, Kgs. Lyngby, Denmark
| | - Robert P Carlyon
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|
6
|
Brochier T, Guérit F, Deeks JM, Garcia C, Bance M, Carlyon RP. Evaluating and Comparing Behavioural and Electrophysiological Estimates of Neural Health in Cochlear Implant Users. J Assoc Res Otolaryngol 2020; 22:67-80. [PMID: 33150541 PMCID: PMC7822986 DOI: 10.1007/s10162-020-00773-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 10/14/2020] [Indexed: 12/12/2022] Open
Abstract
Variations in neural health along the cochlea can degrade the spectral and temporal representation of sounds conveyed by cochlear implants (CIs). We evaluated and compared one electrophysiological measure and two behavioural measures that have been proposed as estimates of neural health patterns, in order to explore the extent to which the different measures provide converging and consistent neural health estimates. All measures were obtained from the same 11 users of the Cochlear Corporation CI. The two behavioural measures were multipulse integration (MPI) and the polarity effect (PE), both measured on each of seven electrodes per subject. MPI was measured as the difference between thresholds at 80 pps and 1000 pps, and PE as the difference in thresholds between cathodic- and anodic-centred quadraphasic (QP) 80-pps pulse trains. It has been proposed that good neural health corresponds to a large MPI and to a large negative PE (lower thresholds for cathodic than anodic pulses). The electrophysiological measure was the effect of interphase gap (IPG) on the offset of the ECAP amplitude growth function (AGF), which has been correlated with spiral ganglion neuron density in guinea pigs. This 'IPG offset' was obtained on the same subset of electrodes used for the behavioural measures. Despite high test-retest reliability, there were no significant correlations between the neural health estimates for either within-subject comparisons across the electrode array, or between-subject comparisons of the means. A phenomenological model of a population of spiral ganglion neurons was then used to investigate physiological mechanisms that might underlie the different neural health estimates. The combined experimental and modelling results provide evidence that PE, MPI and IPG offset may reflect different characteristics of the electrode-neural interface.
Collapse
Affiliation(s)
- Tim Brochier
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK. .,Cambridge Hearing Group, Cambridge University Hospitals Foundation Trust, Hills Road, Cambridge, CB2 0QQ, UK.
| | - François Guérit
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - John M Deeks
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Charlotte Garcia
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge University Hospitals Foundation Trust, Hills Road, Cambridge, CB2 0QQ, UK
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|
7
|
Saeedi A, Hemmert W. Investigation of Electrically Evoked Auditory Brainstem Responses to Multi-Pulse Stimulation of High Frequency in Cochlear Implant Users. Front Neurosci 2020; 14:615. [PMID: 32694972 PMCID: PMC7338891 DOI: 10.3389/fnins.2020.00615] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Accepted: 05/18/2020] [Indexed: 11/13/2022] Open
Abstract
We investigated the effects of electric multi-pulse stimulation on electrically evoked auditory brainstem responses (eABRs). Multi-pulses with a high burst rate of 10,000 pps were assembled from pulses of 45-μs phase duration. Conditions of 1, 2, 4, 8, and 16 pulses were investigated. Psychophysical thresholds (THRs) and most comfortable levels (MCLs) in multi-pulse conditions were measured. Psychophysical temporal integration functions (slopes of THRs/MCLs as a function of number of pulses) were -1.30 and -0.93 dB/doubling of the number of pulses, which correspond to the doubling of pulse duration. A total of 15 eABR conditions with different numbers of pulses and amplitudes were measured. The morphology of eABRs to multi-pulse stimuli did not differ from those to conventional single pulses. eABR wave eV amplitudes and latencies were analyzed extensively. At a fixed stimulation amplitude, an increasing number of pulses caused increasing wave eV amplitudes up to a certain, subject-dependent number of pulses. Then, amplitudes either saturated or even decreased. This contradicted the conventional amplitude growth functions and also contradicted psychophysical results. We showed that destructive interference could be a possible reason for such a finding, where peaks and troughs of responses to the first pulses were suppressed by those of successive pulses in the train. This study provides data on psychophysical THRs and MCLs and corresponding eABR responses for stimulation with single-pulse and multi-pulse stimuli with increasing duration. Therefore, it provides insights how pulse trains integrate at the level of the brainstem.
Collapse
Affiliation(s)
- Ali Saeedi
- Department of Electrical and Computer Engineering, Technical University of Munich, Munich, Germany.,Munich School of Bioengineering, Technical University of Munich, Garching, Germany
| | - Werner Hemmert
- Department of Electrical and Computer Engineering, Technical University of Munich, Munich, Germany.,Munich School of Bioengineering, Technical University of Munich, Garching, Germany
| |
Collapse
|
8
|
Schvartz-Leyzac KC, Holden TA, Zwolan TA, Arts HA, Firszt JB, Buswinka CJ, Pfingst BE. Effects of Electrode Location on Estimates of Neural Health in Humans with Cochlear Implants. J Assoc Res Otolaryngol 2020; 21:259-275. [PMID: 32342256 PMCID: PMC7392989 DOI: 10.1007/s10162-020-00749-0] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Accepted: 02/24/2020] [Indexed: 01/06/2023] Open
Abstract
There are a number of psychophysical and electrophysiological measures that are correlated with SGN density in animal models, and these same measures can be performed in humans with cochlear implants (CIs). Thus, these measures are potentially applicable in humans for estimating the condition of the neural population (so called "neural health" or "cochlear health") at individual sites along the electrode array and possibly adjusting the stimulation strategy in the CI sound processor accordingly. Some measures used to estimate neural health in animals have included the electrically evoked compound potential (ECAP), psychophysical detection thresholds, and multipulse integration (MPI). With regard to ECAP measures, it has been shown that the change in the ECAP response as a function of increasing the stimulus interphase gap ("IPG Effect") also reflects neural density in implanted animals. These animal studies have typically been conducted using preparations in which the electrode was in a fixed position with respect to the neural population, whereas in human cochlear implant users, the position of individual electrodes varies widely within an electrode array and also across subjects. The current study evaluated the effects of electrode location in the implanted cochlea (specifically medial-lateral location) on various electrophysiological and psychophysical measures in eleven human subjects. The results demonstrated that some measures of interest, specifically ECAP thresholds, psychophysical detection thresholds, and ECAP amplitude-growth function (AGF) linear slope, were significantly related to the distances between the electrode and mid-modiolar axis (MMA). These same measures were less strongly related or not significantly related to the electrode to medial wall (MW) distance. In contrast, neither the IPG Effect for the ECAP AGF slope or threshold, nor the MPI slopes were significantly related to MMA or MW distance from the electrodes. These results suggest that "within-channel" estimates of neural health such as the IPG Effect and MPI slope might be more suitable for estimating nerve condition in humans for clinical application since they appear to be relatively independent of electrode position.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
- Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI, 48108, USA.
- Department of Otolaryngology, Medical University of South Carolina, 135 Rutledge Ave, MSC 550, Charleston, SC, 29425, USA.
| | - Timothy A Holden
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Teresa A Zwolan
- Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI, 48108, USA
| | - H Alexander Arts
- Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI, 48108, USA
| | - Jill B Firszt
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Christopher J Buswinka
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| | - Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA
| |
Collapse
|
9
|
Zhou N. Longitudinal effect of deactivating stimulation sites based on low-rate thresholds on speech recognition in cochlear implant users. Int J Audiol 2019; 58:587-597. [PMID: 31012771 DOI: 10.1080/14992027.2019.1601779] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Objective: The objective of the current study was to examine the longitudinal effect of deactivating stimulation sites estimated to produce broad neural excitation on speech recognition. Design: Spatial patterns of neural excitation were estimated based on a previously established psychophysical measure, that is, detection threshold for low-rate pulse trains. Stimulation sites with relatively poor thresholds were deactivated in an experimental map. The acute effect was evaluated, in quiet and in noise, immediately after the experimental map was created (baseline), after the subjects practiced with the experimental map for two months (treatment), and after the subjects' daily map was switched back again to the clinical map for another two months (withdrawal). Study sample: Eight Cochlear Nucleus device users participated in the study. Results: For both listening in noise and in quiet, the greatest effect of deactivation was observed after the subjects were given time to adapt to the new frequency allocations. The effect was comparable for listening in fluctuating and steady-state noises. All subjects benefited from deactivation for listening in noise, but subjects with greater variability in thresholds were more likely to benefit from deactivation for listening in quiet. Conclusion: The benefit of electrode deactivation for speech recognition can increase with practice.
Collapse
Affiliation(s)
- Ning Zhou
- a Department of Communication Sciences and Disorders , East Carolina University , Greenville , NC , USA
| |
Collapse
|
10
|
Carlyon RP, Cosentino S, Deeks JM, Parkinson W, Arenberg JG. Effect of Stimulus Polarity on Detection Thresholds in Cochlear Implant Users: Relationships with Average Threshold, Gap Detection, and Rate Discrimination. J Assoc Res Otolaryngol 2018; 19:559-567. [PMID: 29881937 PMCID: PMC6226408 DOI: 10.1007/s10162-018-0677-5] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 05/18/2018] [Indexed: 12/03/2022] Open
Abstract
Previous psychophysical and modeling studies suggest that cathodic stimulation by a cochlear implant (CI) may preferentially activate the peripheral processes of the auditory nerve, whereas anodic stimulation may preferentially activate the central axons. Because neural degeneration typically starts with loss of the peripheral processes, lower thresholds for cathodic than for anodic stimulation may indicate good local neural survival. We measured thresholds for 99-pulse-per-second trains of triphasic (TP) pulses where the central high-amplitude phase was either anodic (TP-A) or cathodic (TP-C). Thresholds were obtained in monopolar mode from four or five electrodes and a total of eight ears from subjects implanted with the Advanced Bionics CI. When between-subject differences were removed, there was a modest but significant correlation between the polarity effect (TP-C threshold minus TP-A threshold) and the average of TP-C and TP-A thresholds, consistent with the hypothesis that a large polarity effect corresponds to good neural survival. When data were averaged across electrodes for each subject, relatively low thresholds for TP-C correlated with a high "upper limit" (the pulse rate up to which pitch continues to increase) from a previous study (Cosentino et al. J Assoc Otolaryngol 17:371-382). Overall, the results provide modest indirect support for the hypothesis that the polarity effect provides an estimate of local neural survival.
Collapse
Affiliation(s)
- Robert P Carlyon
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK.
| | - Stefano Cosentino
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - John M Deeks
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| | - Wendy Parkinson
- Department of Speech and Hearing Sciences, University of Washington, 1417 NE 42nd St., Seattle, WA, 98105, USA
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, 1417 NE 42nd St., Seattle, WA, 98105, USA
| |
Collapse
|
11
|
DeVries L, Arenberg JG. Psychophysical Tuning Curves as a Correlate of Electrode Position in Cochlear Implant Listeners. J Assoc Res Otolaryngol 2018; 19:571-587. [PMID: 29869047 DOI: 10.1007/s10162-018-0678-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 05/23/2018] [Indexed: 01/04/2023] Open
Abstract
Speech understanding abilities vary widely among cochlear implant (CI) listeners. A potential source of this variability is the electrode-neuron interface (ENI), which includes peripheral factors such as electrode position and integrity of remaining spiral ganglion neurons. Suboptimal positioning of the electrode array has been associated with poorer speech outcomes; however, postoperative computerized tomography (CT) scans are often not available to clinicians. CT-estimated electrode-to-modiolus distance (distance from the inner wall of the cochlea) has been shown to account for some variability in behavioral thresholds. However, psychophysical tuning curves (PTCs) may provide additional insight into site-specific variation in channel interaction. Thirteen unilaterally implanted adults with the Advanced Bionics HiRes90K device participated. Behavioral thresholds and PTCs were collected for all available electrodes with steered quadrupolar (sQP) configuration, using a modified threshold sweep procedure, used in Bierer et al. (Trends Hear 19:1-12, 2015). PTC bandwidths were quantified to characterize channel interaction across the electrode array, and tip shifts were assessed to identify possible contributions of neural dead regions. Broader PTC bandwidths were correlated with electrodes farther from the modiolus, but not correlated with sQP threshold, though a trend was observed. Both measures were affected by scalar location, and PTC tip shifts were observed for electrodes farther from the modiolus. sQP threshold was the only variable correlated with word recognition. These results suggest PTCs may be used as a site-specific measure of channel interaction that correlates with electrode position in some CI listeners.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98106, USA.
| | - Julie G Arenberg
- Department of Speech and Hearing Sciences, University of Washington, 4131 15th Ave NE, Seattle, WA, 98106, USA
| |
Collapse
|
12
|
Zhou N, Cadmus M, Dong L, Mathews J. Temporal Modulation Detection Depends on Sharpness of Spatial Tuning. J Assoc Res Otolaryngol 2018; 19:317-330. [PMID: 29696448 DOI: 10.1007/s10162-018-0663-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Accepted: 03/22/2018] [Indexed: 01/04/2023] Open
Abstract
Prior research has shown that in electrical hearing, cochlear implant (CI) users' speech recognition performance is related in part to their ability to detect temporal modulation (i.e., modulation sensitivity). Previous studies have also shown better speech recognition when selectively stimulating sites with good modulation sensitivity rather than all stimulation sites. Site selection based on channel interaction measures, such as those using imaging or psychophysical estimates of spread of neural excitation, has also been shown to improve speech recognition. This led to the question of whether temporal modulation sensitivity and spatial selectivity of neural excitation are two related variables. In the present study, CI users' modulation sensitivity was compared for sites with relatively broad or narrow neural excitation patterns. This was achieved by measuring temporal modulation detection thresholds (MDTs) at stimulation sites that were significantly different in their sharpness of the psychophysical spatial tuning curves (PTCs) and measuring MDTs at the same sites in monopolar (MP) and bipolar (BP) stimulation modes. Nine postlingually deafened subjects implanted with Cochlear Nucleus® device took part in the study. Results showed a significant correlation between the sharpness of PTCs and MDTs, indicating that modulation detection benefits from a more spatially restricted neural activation pattern. There was a significant interaction between stimulation site and mode. That is, using BP stimulation only improved MDTs at stimulation sites with broad PTCs but had no effect or sometimes a detrimental effect on MDTs at stimulation sites with sharp PTCs. This interaction could suggest that a criterion number of nerve fibers is needed to achieve optimal temporal resolution, and, to achieve optimized speech recognition outcomes, individualized selection of site-specific current focusing strategies may be necessary. These results also suggest that the removal of stimulation sites measured with poor MDTs might improve both temporal and spectral resolution.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27858, USA.
| | - Matthew Cadmus
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27858, USA
| | - Lixue Dong
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27858, USA
| | - Juliana Mathews
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27858, USA
| |
Collapse
|
13
|
Zhou N, Dong L. Evaluating Multipulse Integration as a Neural-Health Correlate in Human Cochlear-Implant Users: Relationship to Psychometric Functions for Detection. Trends Hear 2018; 21:2331216517690108. [PMID: 28150534 PMCID: PMC5308440 DOI: 10.1177/2331216517690108] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
In electrical hearing, multipulse integration (MPI) describes the rate at which detection threshold decreases with increasing stimulation rate in a fixed-duration pulse train. In human subjects, MPI has been shown to be dependent on the psychophysically estimated spread of neural excitation at a high stimulation rate, with broader spread predicting greater integration. The first aim of the present study was to replicate this finding using alternative methods for measuring MPI and spread of neural excitation. The second aim was to test the hypothesis that MPI is related to the slope of the psychometric function for detection. Specifically, a steep d' versus stimulus level function would predict shallow MPI since the amount of current reduction necessary to compensate for an increase in stimulation rate to maintain threshold would be small. The MPI function was measured by obtaining adaptive detection thresholds at 160 and 640 pulses per second. Spread of neural excitation was measured by forward-masked psychophysical tuning curves. All psychophysical testing was performed in a monopolar stimulation mode (MP 1 + 2). Results showed that MPI was correlated with the slopes of the tuning curves, with broader tuning predicting steeper MPI, confirming the earlier finding. However, there was no relationship between MPI and the slopes of the psychometric functions. These results suggest that a broad stimulation of the cochlea facilitates MPI. MPI however is not related to the estimated neural excitation growth with current level near the behavioral threshold, at least in monopolar stimulation.
Collapse
Affiliation(s)
- Ning Zhou
- 1 Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, USA
| | - Lixue Dong
- 1 Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, USA
| |
Collapse
|
14
|
DeVries L, Arenberg JG. Current Focusing to Reduce Channel Interaction for Distant Electrodes in Cochlear Implant Programs. Trends Hear 2018; 22:2331216518813811. [PMID: 30488764 PMCID: PMC6277758 DOI: 10.1177/2331216518813811] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 10/17/2018] [Accepted: 10/26/2018] [Indexed: 11/17/2022] Open
Abstract
Speech understanding abilities are highly variable among cochlear implant (CI) listeners. Poor electrode-neuron interfaces (ENIs) caused by sparse neural survival or distant electrode placement may lead to increased channel interaction and reduced speech perception. Currently, it is not possible to directly measure neural survival in CI listeners; therefore, obtaining information about electrode position is an alternative approach to assessing ENIs. This information can be estimated with computerized tomography (CT) imaging; however, postoperative CT imaging is not often available. A reliable method to assess channel interaction, such as the psychophysical tuning curve (PTC), offers an alternative way to identify poor ENIs. This study aimed to determine (a) the within-subject relationship between CT-estimated electrode distance and PTC bandwidths, and (b) whether using focused stimulation on channels with suspected poor ENI improves vowel identification and sentence recognition. In 13 CI listeners, CT estimates of electrode-to-modiolus distance and PTCs bandwidths were measured for all available electrodes. Two test programs were created, wherein a subset of electrodes used focused stimulation based on (a) broad PTC bandwidth (Tuning) and (b) far electrode-to-modiolus distance (Distance). Two control programs were also created: (a) Those channels not focused in the Distance program (Inverse-Control), and (b) an all-channel monopolar program (Monopolar-Control). Across subjects, scores on the Distance and Tuning programs were significantly higher than the Inverse-Control program, and similar to the Monopolar-Control program. Subjective ratings were similar for all programs. These findings suggest that focusing channels suspected to have a high degree of channel interaction result in quite different outcomes, acutely.
Collapse
Affiliation(s)
- Lindsay DeVries
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Julie G. Arenberg
- Department of Speech and Hearing Sciences, University of Washington, Seattle, WA, USA
| |
Collapse
|
15
|
Evaluating Multipulse Integration as a Neural-Health Correlate in Human Cochlear Implant Users: Effects of Stimulation Mode. J Assoc Res Otolaryngol 2017; 19:99-111. [PMID: 29086155 DOI: 10.1007/s10162-017-0643-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 10/09/2017] [Indexed: 01/04/2023] Open
Abstract
Previous psychophysical studies have shown that a steep detection-threshold-versus-stimulation-rate function (multipulse integration; MPI) is associated with laterally positioned electrodes producing a broad neural excitation pattern. These findings are consistent with steep MPI depending on either a certain width of neural excitation allowing a large population of neurons operating at a low point on their dynamic range to respond to an increase in stimulation rate or a certain slope of excitation pattern that allows recruitment of neurons at the excitation periphery. Results of the current study provide additional support for these mechanisms by demonstrating significantly flattened MPI functions in narrow bipolar than monopolar stimulation. The study further examined the relationship between the steepness of the psychometric functions for detection (d' versus log current level) and MPI. In contrast to findings in monopolar stimulation, current data measured in bipolar stimulation suggest that steepness of the psychometric functions explained a moderate amount of the across-site variance in MPI. Steepness of the psychometric functions, however, cannot explain why MPI flattened in bipolar stimulation, since slopes of the psychometric functions were comparable in the two stimulation modes. Lastly, our results show that across-site mean MPI measured in monopolar and bipolar stimulation correlated with speech recognition in opposite signs, with steeper monopolar MPI being associated with poorer performance but steeper bipolar MPI being associated with better performance. If steeper MPI requires broad stimulation of the cochlea, the correlation between monopolar MPI and speech recognition can be interpreted as the detrimental effect of poor spectral resolution on speech recognition. Assuming bipolar stimulation produces narrow excitation, and MPI measured in bipolar stimulation reflects primarily responses of the on-site neurons, the correlation between bipolar MPI and speech recognition can be understood in light of the importance of neural survival for speech recognition.
Collapse
|
16
|
Zhou N. Deactivating stimulation sites based on low-rate thresholds improves spectral ripple and speech reception thresholds in cochlear implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:EL243. [PMID: 28372106 PMCID: PMC5724621 DOI: 10.1121/1.4977235] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Revised: 01/30/2017] [Accepted: 02/12/2017] [Indexed: 05/26/2023]
Abstract
The study examined whether the benefit of deactivating stimulation sites estimated to have broad neural excitation was attributed to improved spectral resolution in cochlear implant users. The subjects' spatial neural excitation pattern was estimated by measuring low-rate detection thresholds across the array [see Zhou (2016). PLoS One 11, e0165476]. Spectral resolution, as assessed by spectral-ripple discrimination thresholds, significantly improved after deactivation of five high-threshold sites. The magnitude of improvement in spectral-ripple discrimination thresholds predicted the magnitude of improvement in speech reception thresholds after deactivation. Results suggested that a smaller number of relatively independent channels provide a better outcome than using all channels that might interact.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina 27834, USA
| |
Collapse
|
17
|
Zhou N. Monopolar Detection Thresholds Predict Spatial Selectivity of Neural Excitation in Cochlear Implants: Implications for Speech Recognition. PLoS One 2016; 11:e0165476. [PMID: 27798658 PMCID: PMC5087957 DOI: 10.1371/journal.pone.0165476] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Accepted: 10/12/2016] [Indexed: 12/12/2022] Open
Abstract
The objectives of the study were to (1) investigate the potential of using monopolar psychophysical detection thresholds for estimating spatial selectivity of neural excitation with cochlear implants and to (2) examine the effect of site removal on speech recognition based on the threshold measure. Detection thresholds were measured in Cochlear Nucleus® device users using monopolar stimulation for pulse trains that were of (a) low rate and long duration, (b) high rate and short duration, and (c) high rate and long duration. Spatial selectivity of neural excitation was estimated by a forward-masking paradigm, where the probe threshold elevation in the presence of a forward masker was measured as a function of masker-probe separation. The strength of the correlation between the monopolar thresholds and the slopes of the masking patterns systematically reduced as neural response of the threshold stimulus involved interpulse interactions (refractoriness and sub-threshold adaptation), and spike-rate adaptation. Detection threshold for the low-rate stimulus most strongly correlated with the spread of forward masking patterns and the correlation reduced for long and high rate pulse trains. The low-rate thresholds were then measured for all electrodes across the array for each subject. Subsequently, speech recognition was tested with experimental maps that deactivated five stimulation sites with the highest thresholds and five randomly chosen ones. Performance with deactivating the high-threshold sites was better than performance with the subjects' clinical map used every day with all electrodes active, in both quiet and background noise. Performance with random deactivation was on average poorer than that with the clinical map but the difference was not significant. These results suggested that the monopolar low-rate thresholds are related to the spatial neural excitation patterns in cochlear implant users and can be used to select sites for more optimal speech recognition performance.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, NC, United States of America
- * E-mail:
| |
Collapse
|