Huang X, Huang J, Su P, Li W. Fast Blood Oxygenation through Hemocompatible Asymmetric Polymer of Intrinsic Microporosity Membranes. RESEARCH (WASHINGTON, D.C.) 2023; 6:0151. [PMID: 37214199 PMCID: PMC10195972 DOI: 10.34133/research.0151] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 04/27/2023] [Indexed: 05/24/2023]
Abstract
Membrane technology has attracted considerable attention for chemical and medical applications, among others. Artificial organs play important roles in medical science. A membrane oxygenator, also known as artificial lung, can replenish O2 and remove CO2 of blood to maintain the metabolism of patients with cardiopulmonary failure. However, the membrane, a key component, is subjected to inferior gas transport property, leakage propensity, and insufficient hemocompatibility. In this study, we report efficient blood oxygenation by using an asymmetric nanoporous membrane that is fabricated using the classic nonsolvent-induced phase separation method for polymer of intrinsic microporosity-1. The intrinsic superhydrophobic nanopores and asymmetric configuration endow the membrane with water impermeability and gas ultrapermeability, up to 3,500 and 1,100 gas permeation units for CO2 and O2, respectively. Moreover, the rational hydrophobic-hydrophilic nature, electronegativity, and smoothness of the surface enable the substantially restricted protein adsorption, platelet adhesion and activation, hemolysis, and thrombosis for the membrane. Importantly, during blood oxygenation, the asymmetric nanoporous membrane shows no thrombus formation and plasma leakage and exhibits fast O2 and CO2 transport processes with exchange rates of 20 to 60 and 100 to 350 ml m-2 min-1, respectively, which are 2 to 6 times higher than those of conventional membranes. The concepts reported here offer an alternative route to fabricate high-performance membranes and expand the possibilities of nanoporous materials for membrane-based artificial organs.
Collapse
|
2
|
Strudthoff LJ, Focke J, Hesselmann F, Kaesler A, Martins Costa A, Schlanstein PC, Schmitz-Rode T, Steinseifer U, Steuer NB, Wiegmann B, Arens J, Jansen SV. Novel Size-Variable Dedicated Rodent Oxygenator for ECLS Animal Models-Introduction of the "RatOx" Oxygenator and Preliminary In Vitro Results. MICROMACHINES 2023; 14:800. [PMID: 37421033 DOI: 10.3390/mi14040800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/22/2023] [Accepted: 03/24/2023] [Indexed: 07/09/2023]
Abstract
The overall survival rate of extracorporeal life support (ECLS) remains at 60%. Research and development has been slow, in part due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator ("RatOx") and presents preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performances over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199. At the maximum possible amount of effective fiber surface area and a blood flow of 100 mL/min, the oxygenator performance was tested to a maximum of 6.27 mL O2/min and 8.2 mL CO2/min, respectively. The priming volume for the largest fiber module is 5.4 mL, while the smallest possible configuration with a single fiber mat layer has a priming volume of 1.1 mL. The novel RatOx ECLS system has been evaluated in vitro and has demonstrated a high degree of compliance with all pre-defined functional criteria for rodent-sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.
Collapse
Affiliation(s)
- Lasse J Strudthoff
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Jannis Focke
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Felix Hesselmann
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Andreas Kaesler
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Ana Martins Costa
- Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, 7522 LW Enschede, The Netherlands
| | - Peter C Schlanstein
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Ulrich Steinseifer
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Niklas B Steuer
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Bettina Wiegmann
- Department for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, 30625 Hanover, Germany
- Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), 30625 Hanover, Germany
- German Center for Lung Research (DLZ), 30625 Hanover, Germany
| | - Jutta Arens
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
- Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, 7522 LW Enschede, The Netherlands
| | - Sebastian V Jansen
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| |
Collapse
|