Lin J, Chen S, Zhang C, Liao J, Chen Y, Deng S, Mao Z, Zhang T, Tian N, Song Y, Zeng T. Recent advances in microfluidic technology of arterial thrombosis investigations. Platelets 2024; 35:2316743. [PMID: 38390892 DOI: 10.1080/09537104.2024.2316743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 02/05/2024] [Indexed: 02/24/2024]
Abstract
Microfluidic technology has emerged as a powerful tool in studying arterial thrombosis, allowing researchers to construct artificial blood vessels and replicate the hemodynamics of blood flow. This technology has led to significant advancements in understanding thrombosis and platelet adhesion and aggregation. Microfluidic models have various types and functions, and by studying the fabrication methods and working principles of microfluidic chips, applicable methods can be selected according to specific needs. The rapid development of microfluidic integrated system and modular microfluidic system makes arterial thrombosis research more diversified and automated, but its standardization still needs to be solved urgently. One key advantage of microfluidic technology is the ability to precisely control fluid flow in microchannels and to analyze platelet behavior under different shear forces and flow rates. This allows researchers to study the physiological and pathological processes of blood flow, shedding light on the underlying mechanisms of arterial thrombosis. In conclusion, microfluidic technology has revolutionized the study of arterial thrombosis by enabling the construction of artificial blood vessels and accurately reproducing hemodynamics. In the future, microfluidics will place greater emphasis on versatility and automation, holding great promise for advancing antithrombotic therapeutic and prophylactic measures.
Collapse
Affiliation(s)
- Jingying Lin
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
- Department of Laboratory Medicine, Chengdu Shangjin Nanfu Hospital/Shangjin Branch of West China Hospital, Sichuan University, Chengdu, China
| | - Si Chen
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Chunying Zhang
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Juan Liao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Yuemei Chen
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Shanying Deng
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Zhigang Mao
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Tonghao Zhang
- Department of Statistics, University of Virginia, Charlottesville, USA
| | - Na Tian
- Anesthesiology Department, Qingdao Eighth People's Hospital, Qingdao, China
| | - Yali Song
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Tingting Zeng
- Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
2
|
Anderson D, Le H, Vu H, Johnson J, Aslan J, Goldman J, Hinds M. Thrombogenicity of biodegradable metals. Bioact Mater 2024; 38:411-421. [PMID: 38774458 PMCID: PMC11107095 DOI: 10.1016/j.bioactmat.2024.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 04/10/2024] [Accepted: 05/02/2024] [Indexed: 05/24/2024] Open
Abstract
Biodegradable metals offer a promising means to ameliorate many of the long-term risks associated with vascular devices made of conventional biostable stent metals. While numerous biodegradable metal alloys have been developed and characterized in animal models, knowledge of their blood reactivity and thrombogenicity remains unknown. Metal hemocompatibility is particularly valuable because current generation drug-eluting stents pose a significant long-term thrombosis risk. In this study, four pure metals, widely used as degradable base materials (Fe, Zn, Mg, and Mo), and three alloys commonly used in cardiovascular devices [NiTi, CoCr, and stainless steel (SS)] were evaluated. This work examined how each of these metals activate platelets, coagulation factors, and inflammation using in vitro hemocompatibility assays and a clinically relevant ex vivo non-human primate arteriovenous shunt model. Testing found that while all metals promoted a downstream activation of platelets and coagulation in flowing whole blood, platelet and fibrin attachment to Mg was markedly reduced. Additionally, Fe and Mo trended toward higher platelet attachment and contact pathway activation. Overall, the results suggest that Mg may delay clot initiation, but not eliminate clot formation, indicating the importance of understanding thrombosis in Mg alloys that are currently being developed for clinical use as biodegradable stents.
Collapse
Affiliation(s)
- D.E.J. Anderson
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - H.H. Le
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - H. Vu
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - J. Johnson
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - J.E. Aslan
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - J. Goldman
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, USA
| | - M.T. Hinds
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
3
|
Keeling NM, Wallisch M, Johnson J, Le HH, Vu HH, Jordan KR, Puy C, Tucker EI, Nguyen KP, McCarty OJT, Aslan JE, Hinds MT, Anderson DEJ. Pharmacologic targeting of coagulation factors XII and XI by monoclonal antibodies reduces thrombosis in nitinol stents under flow. J Thromb Haemost 2024; 22:1433-1446. [PMID: 38331196 PMCID: PMC11055672 DOI: 10.1016/j.jtha.2024.01.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 01/11/2024] [Accepted: 01/28/2024] [Indexed: 02/10/2024]
Abstract
BACKGROUND Cardiovascular implantable devices, such as vascular stents, are critical for the treatment of cardiovascular diseases. However, their success is dependent on robust and often long-term antithrombotic therapies. Yet, the current standard-of-care therapies often pose significant bleeding risks to patients. Coagulation factor (F)XI and FXII have emerged as potentially safe and efficacious targets to safely reduce pathologic thrombin generation in medical devices. OBJECTIVES To study the efficacy of monoclonal antibody-targeting FXII and FXI of the contact pathway in preventing vascular device-related thrombosis. METHODS The effects of inhibition of FXII and FXI using function-blocking monoclonal antibodies were examined in a nonhuman primate model of nitinol stent-related thrombosis under arterial and venous flow conditions. RESULTS We found that function-blocking antibodies of FXII and FXI reduced markers of stent-induced thrombosis in vitro and ex vivo. However, FXI inhibition resulted in more effective mitigation of thrombosis markers under varied flow conditions. CONCLUSION This work provides further support for the translation of contact pathway of coagulation inhibitors for their adjunctive clinical use with cardiovascular devices.
Collapse
Affiliation(s)
- Novella M Keeling
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA; Biomedical Engineering Program, University of Colorado Boulder, Boulder, Colorado, USA.
| | - Michael Wallisch
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA; Aronora Inc, Portland, Oregon, USA
| | - Jennifer Johnson
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Hillary H Le
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Helen H Vu
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Kelley R Jordan
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Cristina Puy
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Erik I Tucker
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA; Aronora Inc, Portland, Oregon, USA
| | - Khanh P Nguyen
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA; Veterans Affairs Portland Health Care System, Portland, Oregon, USA
| | - Owen J T McCarty
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA; Division of Hematology & Medical Oncology, Oregon Health & Science University, Portland, Oregon, USA
| | - Joseph E Aslan
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA; Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon, USA
| | - Monica T Hinds
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA
| | - Deirdre E J Anderson
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon, USA.
| |
Collapse
|
4
|
Gurkan UA, Wood DK, Carranza D, Herbertson LH, Diamond SL, Du E, Guha S, Di Paola J, Hines PC, Papautsky I, Shevkoplyas SS, Sniadecki NJ, Pamula VK, Sundd P, Rizwan A, Qasba P, Lam WA. Next generation microfluidics: fulfilling the promise of lab-on-a-chip technologies. LAB ON A CHIP 2024; 24:1867-1874. [PMID: 38487919 DOI: 10.1039/d3lc00796k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
Microfluidic lab-on-a-chip technologies enable the analysis and manipulation of small fluid volumes and particles at small scales and the control of fluid flow and transport processes at the microscale, leading to the development of new methods to address a broad range of scientific and medical challenges. Microfluidic and lab-on-a-chip technologies have made a noteworthy impact in basic, preclinical, and clinical research, especially in hematology and vascular biology due to the inherent ability of microfluidics to mimic physiologic flow conditions in blood vessels and capillaries. With the potential to significantly impact translational research and clinical diagnostics, technical issues and incentive mismatches have stymied microfluidics from fulfilling this promise. We describe how accessibility, usability, and manufacturability of microfluidic technologies should be improved and how a shift in mindset and incentives within the field is also needed to address these issues. In this report, we discuss the state of the microfluidic field regarding current limitations and propose future directions and new approaches for the field to advance microfluidic technologies closer to translation and clinical use. While our report focuses on using blood as the prototypical biofluid sample, the proposed ideas and research directions can be extrapolated to other areas of hematology, oncology, biology, and medicine.
Collapse
Affiliation(s)
| | | | | | | | | | - E Du
- Florida Atlantic University, USA
| | | | | | - Patrick C Hines
- Wayne State University School of Medicine, USA
- Functional Fluidics, Inc., USA
| | | | | | | | | | - Prithu Sundd
- VERSITI Blood Research Institute and Medical College of Wisconsin, USA
| | - Asif Rizwan
- National Heart, Lung, and Blood Institute, USA
| | | | | |
Collapse
|
5
|
Teeraratkul C, Tomaiuolo M, Stalker TJ, Mukherjee D. Investigating clot-flow interactions by integrating intravital imaging with in silico modeling for analysis of flow, transport, and hemodynamic forces. Sci Rep 2024; 14:696. [PMID: 38184693 PMCID: PMC10771506 DOI: 10.1038/s41598-023-49945-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 12/13/2023] [Indexed: 01/08/2024] Open
Abstract
As a blood clot forms, grows, deforms, and embolizes following a vascular injury, local clot-flow interactions lead to a highly dynamic flow environment. The local flow influences transport of biochemical species relevant for clotting, and determines the forces on the clot that in turn lead to clot deformation and embolization. Despite this central role, quantitative characterization of this dynamic clot-flow interaction and flow environment in the clot neighborhood remains a major challenge. Here, we propose an approach that integrates dynamic intravital imaging with computer geometric modeling and computational flow and transport modeling to develop a unified in silico framework to quantify the dynamic clot-flow interactions. We outline the development of the methodology referred to as Intravital Integrated In Silico Modeling or IVISim, and then demonstrate the method on a sample set of simulations comprising clot formation following laser injury in two mouse cremaster arteriole injury model data: one wild-type mouse case, and one diYF knockout mouse case. Simulation predictions are verified against experimental observations of transport of caged fluorescent Albumin (cAlb) in both models. Through these simulations, we illustrate how the IVISim methodology can provide insights into hemostatic processes, the role of flow and clot-flow interactions, and enable further investigations comparing and contrasting different biological model scenarios and parameter variations.
Collapse
Affiliation(s)
- Chayut Teeraratkul
- Paul M Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| | - Maurizio Tomaiuolo
- Cardeza Foundation for Hematologic Research, Department of Medicine, Thomas Jefferson University, Philadelphia, USA
| | | | - Debanjan Mukherjee
- Paul M Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA.
| |
Collapse
|
6
|
Dai H, Chai S, Yao Y, Tang W, Shi J, Jiang Q, Zhu L. Effect of intermittent pneumatic compression on preventing deep vein thrombosis using microfluidic vein chip. Front Bioeng Biotechnol 2023; 11:1281503. [PMID: 38026856 PMCID: PMC10679410 DOI: 10.3389/fbioe.2023.1281503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/25/2023] [Indexed: 12/01/2023] Open
Abstract
Background: Deep Vein Thrombosis (DVT) is a common disease, frequently afflicting the lower limb veins of bedridden patients. Intermittent Pneumatic Compression (IPC) is often employed as an effective solution for this problem. In our study, a random selection of 264 patients underwent IPC treatment for either one or 8 hours daily. The rate of severe venous thrombosis was substantially reduced in the IPC-treated group compared to the control group. However, real-time monitoring of blood flow during IPC operation periods remains a challenge, leading to rare awareness of IPC working mechanism on thrombosis prevention. Methods: Here, microfluidic chip methodology is used to create an in vitro vein-mimicking platform integrating venous valves in a deformable channel. Whole blood of patients after knee surgery was perfused into the venous channel at a controlled flow rate obtained from patients with IPC treatment clinically. Results: According to the numerical simulations results, both of an increase in compressive pressure and a decrease in time interval of IPC device can accelarete blood flow rate and the shear stress within the vein. The vein chip experiments also reveal that the fibrin accumulation can be greatly lowered in IPC treated group, indicating less thrombosis formation in future. A time interval of 24 seconds and a maximum contraction pressure of 40 mmHg were proved to be the most effective parameters for the IPC device adopted in our clinical trail. Conclusion: This vein chip presents a novel method for observing the functional mechanisms of IPC device for DVT prevention. It provides crucial data for further standardization and optimization of IPC devices in clinical usage.
Collapse
Affiliation(s)
- Hongtao Dai
- Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China
| | - Senlin Chai
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Drum Tower Hospital Affiliated to Medical School of Nanjing University, Nanjing University, Nanjing, China
| | - Yao Yao
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Drum Tower Hospital Affiliated to Medical School of Nanjing University, Nanjing University, Nanjing, China
| | - Wenlai Tang
- Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China
- Guangdong Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, School of Electromechanically Engineering, Guangdong University of Technology, Guangzhou, China
| | - Jianping Shi
- Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China
| | - Qing Jiang
- State Key Laboratory of Pharmaceutical Biotechnology, Division of Sports Medicine and Adult Reconstructive Surgery, Department of Orthopedic Surgery, Drum Tower Hospital Affiliated to Medical School of Nanjing University, Nanjing University, Nanjing, China
| | - Liya Zhu
- Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China
| |
Collapse
|
7
|
Juste-Lanas Y, Hervas-Raluy S, García-Aznar JM, González-Loyola A. Fluid flow to mimic organ function in 3D in vitro models. APL Bioeng 2023; 7:031501. [PMID: 37547671 PMCID: PMC10404142 DOI: 10.1063/5.0146000] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 06/20/2023] [Indexed: 08/08/2023] Open
Abstract
Many different strategies can be found in the literature to model organ physiology, tissue functionality, and disease in vitro; however, most of these models lack the physiological fluid dynamics present in vivo. Here, we highlight the importance of fluid flow for tissue homeostasis, specifically in vessels, other lumen structures, and interstitium, to point out the need of perfusion in current 3D in vitro models. Importantly, the advantages and limitations of the different current experimental fluid-flow setups are discussed. Finally, we shed light on current challenges and future focus of fluid flow models applied to the newest bioengineering state-of-the-art platforms, such as organoids and organ-on-a-chip, as the most sophisticated and physiological preclinical platforms.
Collapse
Affiliation(s)
| | - Silvia Hervas-Raluy
- Department of Mechanical Engineering, Engineering Research Institute of Aragón (I3A), University of Zaragoza, Zaragoza, Spain
| | | | | |
Collapse
|
8
|
Ballard-Kordeliski A, Lee RH, O'Shaughnessy EC, Kim PY, Jones S, Mackman N, Flick MJ, Paul DS, Adalsteinsson D, Bergmeier W. 4D intravital imaging studies identify platelets as the predominant cellular procoagulant surface in a mouse model of hemostasis. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.08.25.554449. [PMID: 37662350 PMCID: PMC10473702 DOI: 10.1101/2023.08.25.554449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
Interplay between platelets, coagulation/fibrinolytic factors, and endothelial cells (ECs) is necessary for effective hemostatic plug formation. This study describes a novel four-dimensional (4D) imaging platform to visualize and quantify hemostatic plug components with high spatiotemporal resolution. Fibrin accumulation following laser-induced endothelial ablation was observed at the EC-platelet plug interface, controlled by the antagonistic balance between fibrin generation and breakdown. Phosphatidylserine (PS) was first detected in close physical proximity to the fibrin ring, followed by exposure across the endothelium. Impaired PS exposure in cyclophilinD -/- mice resulted in a significant reduction in fibrin accumulation. Adoptive transfer and inhibitor studies demonstrated a key role for platelets, but not ECs, in fibrin generation during hemostatic plug formation. Inhibition of fibrinolysis with tranexamic acid (TXA) led to increased fibrin accumulation in WT mice, but not in cyclophilinD -/- mice or WT mice treated with antiplatelet drugs. These studies implicate platelets as the functionally dominant procoagulant surface during hemostatic plug formation. In addition, they suggest that impaired fibrin formation due to reduced platelet procoagulant activity is not reversed by TXA treatment.
Collapse
|
9
|
Li J, Zhang Y, Zou C, Chen Y, Li Y, Chen H. Binding properties of flowing fibrin-targeted microbubbles evaluated with a thrombus-embedded microchannel. LAB ON A CHIP 2022; 22:2292-2298. [PMID: 35616180 DOI: 10.1039/d1lc01037a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Fibrin is found in both arterial and venous thrombi, which provides an important target for thrombus-targeted microbubbles (MBs) used in MB-enhanced ultrasound imaging and sonothrombolysis. A fibrin-targeted peptide, Cys-Arg-Glu-Lys-Ala (CREKA), is used to modify the commercially available SonoVue ultrasound contrast agent using a conjugation method, and the binding capacity and binding strength of the fibrin-targeted CREKA-modified SonoVue MBs are evaluated with a thrombus-embedded microchannel at a typical shear rate range of venous and arterial blood flow. The experimental results indicate that the targeted MBs bind firmly to the thrombus surface when they flow along the microchannel at a wall shear rate of up to 1000 s-1. This work not only provides an effective method for the fabrication of fibrin-targeted MBs based on commercially available SonoVue MBs but also demonstrates an approach for evaluation of the binding properties of flowing targeted MBs under well-controlled flow conditions.
Collapse
Affiliation(s)
- Jiang Li
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Yuan Zhang
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Chenghong Zou
- School of Mechanical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Yuexin Chen
- Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| | - Yongjian Li
- State Key Laboratory of Tribology, Tsinghua University, Beijing 100084, China.
| | - Haosheng Chen
- State Key Laboratory of Tribology, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
10
|
Mutch NJ, Walters S, Gardiner EE, McCarty OJT, De Meyer SF, Schroeder V, Meijers JCM. Basic science research opportunities in thrombosis and hemostasis: Communication from the SSC of the ISTH. J Thromb Haemost 2022; 20:1496-1506. [PMID: 35352482 PMCID: PMC9325489 DOI: 10.1111/jth.15718] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/23/2022] [Accepted: 03/23/2022] [Indexed: 11/30/2022]
Abstract
Bleeding and thrombosis are major clinical problems with high morbidity and mortality. Treatment modalities for these diseases have improved in recent years, but there are many clinical questions remaining and a need to advance diagnosis, management, and therapeutic options. Basic research plays a fundamental role in understanding normal and disease processes, yet this sector has observed a steady decline in funding prospects thereby hindering support for studies of mechanisms of disease and therapeutic development opportunities. With the financial constraints faced by basic scientists, the ISTH organized a basic science task force (BSTF), comprising Scientific and Standardization Committee subcommittee chairs and co-chairs, to identify research opportunities for basic science in hemostasis and thrombosis. The goal of the BSTF was to develop a set of recommended priorities to build support in the thrombosis and hemostasis community and to inform ISTH basic science programs and policy making. The BSTF identified three principal opportunity areas that were of significant overarching relevance: mechanisms causing bleeding, innate immunity and thrombosis, and venous thrombosis. Within these, five fundamental research areas were highlighted: blood rheology, platelet biogenesis, cellular contributions to thrombosis and hemostasis, structure-function protein analyses, and visualization of hemostasis. This position paper discusses the importance and relevance of these opportunities and research areas, and the rationale for their inclusion. These findings have implications for the future of fundamental research in thrombosis and hemostasis to make transformative scientific discoveries and tackle key clinical questions. This will permit better understanding, prevention, diagnosis, and treatment of hemostatic and thrombotic conditions.
Collapse
Affiliation(s)
- Nicola J. Mutch
- Aberdeen Cardiovascular & Diabetes CentreInstitute of Medical SciencesSchool of MedicineMedical Sciences and NutritionUniversity of AberdeenAberdeenUK
| | | | - Elizabeth E. Gardiner
- John Curtin School of Medical ResearchThe Australian National UniversityCanberraAustralian Capital TerritoryAustralia
| | - Owen J. T. McCarty
- Departments of Biomedical Engineering and MedicineOregon Health & Science UniversityPortlandOregonUSA
| | - Simon F. De Meyer
- Laboratory for Thrombosis ResearchKU Leuven Campus Kulak KortrijkKortrijkBelgium
| | - Verena Schroeder
- Department for BioMedical Research (DBMR)University of BernBernSwitzerland
| | - Joost C. M. Meijers
- Department of Molecular HematologySanquin ResearchAmsterdamthe Netherlands
- Department of Experimental Vascular Medicine, Amsterdam Cardiovascular SciencesAmsterdam UMCUniversity of AmsterdamAmsterdamthe Netherlands
| |
Collapse
|
11
|
A Parametric Analysis of Capillary Height in Single-Layer, Small-Scale Microfluidic Artificial Lungs. MICROMACHINES 2022; 13:mi13060822. [PMID: 35744436 PMCID: PMC9229210 DOI: 10.3390/mi13060822] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 05/23/2022] [Accepted: 05/23/2022] [Indexed: 02/04/2023]
Abstract
Microfluidic artificial lungs (μALs) are being investigated for their ability to closely mimic the size scale and cellular environment of natural lungs. Researchers have developed μALs with small artificial capillary diameters (10–50 µm; to increase gas exchange efficiency) and with large capillary diameters (~100 µm; to simplify design and construction). However, no study has directly investigated the impact of capillary height on μAL properties. Here, we use Murray’s law and the Hagen-Poiseuille equation to design single-layer, small-scale μALs with capillary heights between 10 and 100 µm. Each µAL contained two blood channel types: capillaries for gas exchange; and distribution channels for delivering blood to/from capillaries. Three designs with capillary heights of 30, 60, and 100 µm were chosen for further modeling, implementation and testing with blood. Flow simulations were used to validate and ensure equal pressures. Designs were fabricated using soft lithography. Gas exchange and pressure drop were tested using whole bovine blood. All three designs exhibited similar pressure drops and gas exchange; however, the μAL with 60 µm tall capillaries had a significantly higher wall shear rate (although physiologic), smaller priming volume and smaller total blood contacting surface area than the 30 and 100 µm designs. Future μAL designs may need to consider the impact of capillary height when optimizing performance.
Collapse
|
12
|
Xu Y, Yu G, Nie R, Wu Z. Microfluidic systems toward blood hemostasis monitoring and thrombosis diagnosis: From design principles to micro/nano fabrication technologies. VIEW 2022. [DOI: 10.1002/viw.20200183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- Yi Xu
- Soft Intelligence Lab State Key Laboratory of Digital Manufacturing Equipment and Technology School of Mechanical Science and Engineering Huazhong University of Science and Technology Wuhan China
| | - Guang Yu
- Experimental Medicine Center Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China
| | - Ruqiong Nie
- Department of Cardiology Sun Yat‐Sen Memorial Hospital Sun Yat‐Sen University Guangzhou China
| | - Zhigang Wu
- Soft Intelligence Lab State Key Laboratory of Digital Manufacturing Equipment and Technology School of Mechanical Science and Engineering Huazhong University of Science and Technology Wuhan China
| |
Collapse
|
13
|
Mencarini T, Bozzi S, Redaelli A. On-Chip Platelet Activation Assessment: Microfluidic Emulation of Shear Stress Profiles Induced by Mechanical Circulatory Support Devices. Methods Mol Biol 2022; 2373:201-212. [PMID: 34520014 DOI: 10.1007/978-1-0716-1693-2_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Mechanical circulatory support devices (MCSDs), although proved to be a pillar in the clinical setting of advanced heart failure, are afflicted by thromboembolic complications. Shear-mediated platelet activation has been recognized to drive thromboembolic events in patients implanted with MCSDs. Despite this, to date, a clinically reliable diagnostic test for assessing platelet response to stress stimuli is still missing. Here, we describe and apply the previously developed device thrombogenicity emulation methodology to the design of a microfluidic platform able to replicate shear stress profiles representative of MCSDs. The device-specific shear-mediated platelet activation is finally assessed by the platelet activity state assay, which measures real-time thrombin production, as a marker of platelet activation level. This technique can be employed to emulate the shear stress patterns of different MCSDs, such as mechanical heart valves, ventricular assist devices, and stents.
Collapse
Affiliation(s)
- Tatiana Mencarini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Silvia Bozzi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| |
Collapse
|
14
|
Zhang Y, Ramasundara SDZ, Preketes-Tardiani RE, Cheng V, Lu H, Ju LA. Emerging Microfluidic Approaches for Platelet Mechanobiology and Interplay With Circulatory Systems. Front Cardiovasc Med 2021; 8:766513. [PMID: 34901226 PMCID: PMC8655735 DOI: 10.3389/fcvm.2021.766513] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Accepted: 10/15/2021] [Indexed: 12/29/2022] Open
Abstract
Understanding how platelets can sense and respond to hemodynamic forces in disturbed blood flow and complexed vasculature is crucial to the development of more effective and safer antithrombotic therapeutics. By incorporating diverse structural and functional designs, microfluidic technologies have emerged to mimic microvascular anatomies and hemodynamic microenvironments, which open the floodgates for fascinating platelet mechanobiology investigations. The latest endothelialized microfluidics can even recapitulate the crosstalk between platelets and the circulatory system, including the vessel walls and plasma proteins such as von Willebrand factor. Hereby, we highlight these exciting microfluidic applications to platelet mechanobiology and platelet–circulatory system interplay as implicated in thrombosis. Last but not least, we discuss the need for microfluidic standardization and summarize the commercially available microfluidic platforms for researchers to obtain reproducible and consistent results in the field.
Collapse
Affiliation(s)
- Yingqi Zhang
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia
| | - Savindi De Zoysa Ramasundara
- Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia.,School of Medicine, The University of Notre Dame Sydney, Darlinghurst, NSW, Australia
| | - Renee Ellen Preketes-Tardiani
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia
| | - Vivian Cheng
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia
| | - Hongxu Lu
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Faculty of Science, Institute for Biomedical Materials and Devices, The University of Technology Sydney, Ultimo, NSW, Australia
| | - Lining Arnold Ju
- School of Biomedical Engineering, Faculty of Engineering, The University of Sydney, Darlington, NSW, Australia.,Charles Perkins Centre, The University of Sydney, Camperdown, NSW, Australia.,Heart Research Institute, Newtown, NSW, Australia
| |
Collapse
|
15
|
Padilla S, Nurden AT, Prado R, Nurden P, Anitua E. Healing through the lens of immunothrombosis: Biology-inspired, evolution-tailored, and human-engineered biomimetic therapies. Biomaterials 2021; 279:121205. [PMID: 34710794 DOI: 10.1016/j.biomaterials.2021.121205] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 09/30/2021] [Accepted: 10/20/2021] [Indexed: 12/14/2022]
Abstract
Evolution, from invertebrates to mammals, has yielded and shaped immunoclotting as a defense and repair response against trauma and infection. This mosaic of immediate and local wound-sealing and pathogen-killing mechanisms results in survival, restoration of homeostasis, and tissue repair. In mammals, immunoclotting has been complemented with the neuroendocrine system, platelets, and contact system among other embellishments, adding layers of complexity through interconnecting blood-born proteolytic cascades, blood cells, and the neuroendocrine system. In doing so, immunothrombosis endows humans with survival advantages, but entails vulnerabilities in the current unprecedented and increasingly challenging environment. Immunothrombosis and tissue repair appear to go hand in hand with common mechanisms mediating both processes, a fact that is underlined by recent advances that are deciphering the mechanisms of the repair process and of the biochemical pathways that underpins coagulation, hemostasis and thrombosis. This review is intended to frame both the universal aspects of tissue repair and the therapeutic use of autologous fibrin matrix as a biology-as-a-drug approach in the context of the evolutionary changes in coagulation and hemostasis. In addition, we will try to shed some light on the molecular mechanisms underlying the use of the autologous fibrin matrix as a biology-inspired, evolution-tailored, and human-engineered biomimetic therapy.
Collapse
Affiliation(s)
- Sabino Padilla
- Eduardo Anitua Foundation for Biomedical Research, Vitoria, Spain; BTI-Biotechnology Institute ImasD, Vitoria, Spain; University Institute for Regenerative Medicine & Oral Implantology - UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, Spain.
| | - Alan T Nurden
- Institut Hospitalo-Universitaire LIRYC, Hôpital Xavier Arnozan, Pessac, France
| | - Roberto Prado
- Eduardo Anitua Foundation for Biomedical Research, Vitoria, Spain; BTI-Biotechnology Institute ImasD, Vitoria, Spain; University Institute for Regenerative Medicine & Oral Implantology - UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, Spain
| | - Paquita Nurden
- Institut Hospitalo-Universitaire LIRYC, Hôpital Xavier Arnozan, Pessac, France
| | - Eduardo Anitua
- Eduardo Anitua Foundation for Biomedical Research, Vitoria, Spain; BTI-Biotechnology Institute ImasD, Vitoria, Spain; University Institute for Regenerative Medicine & Oral Implantology - UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, Spain.
| |
Collapse
|
16
|
Diamond SL, Rossi JM. Point of care whole blood microfluidics for detecting and managing thrombotic and bleeding risks. LAB ON A CHIP 2021; 21:3667-3674. [PMID: 34476426 PMCID: PMC8478847 DOI: 10.1039/d1lc00465d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Point-of-care diagnostics of platelet and coagulation function present demanding challenges. Current clinical diagnostics often use centrifuged plasmas or platelets and frozen plasma standards, recombinant protein standards, or even venoms. Almost all commercialized tests of blood do not recreate the in vivo hemodynamics where platelets accumulate to high densities and thrombin is generated from a procoagulant surface. Despite numerous drugs that target platelets, insufficient coagulation, or excess coagulation, POC blood testing is essentially limited to viscoelastic methods that provide a clotting time, clot strength, and clot lysis, while used mostly in trauma centers with specialized capabilities. Microfluidics now allows small volumes of whole blood (<1 mL) to be tested under venous or arterial shear rates with multi-color readouts to follow platelet function, thrombin generation, fibrin production, and clot stability. Injection molded chips containing pre-patterned fibrillar collagen and lipidated tissue factor can be stored dry for 6 months at 4C, thus allowing rapid blood testing on single-use disposable chips. Using only a small imaging microscope and micropump, these microfluidic devices can detect platelet inhibitors, direct oral anticoagulants (DOACs) and their reversal agents. POC microfluidics are ideal for neonatal surgical applications that involve small blood samples, rapid DOAC testing in stroke or bleeding or emergency surgery situations with patients presenting high risk cofactors for either bleeding or thrombosis.
Collapse
Affiliation(s)
- Scott L Diamond
- Institute for Medicine and Engineering, Department of Chemical and Biomolecular Engineering, University of Pennsylvania, 1024 Vagelos Research Laboratory, Philadelphia, PA 19104, USA.
| | - Jason M Rossi
- Institute for Medicine and Engineering, Department of Chemical and Biomolecular Engineering, University of Pennsylvania, 1024 Vagelos Research Laboratory, Philadelphia, PA 19104, USA.
| |
Collapse
|
17
|
Wang Y, Nunna BB, Talukder N, Etienne EE, Lee ES. Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms. Bioengineering (Basel) 2021; 8:94. [PMID: 34356201 PMCID: PMC8301051 DOI: 10.3390/bioengineering8070094] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 06/19/2021] [Accepted: 06/30/2021] [Indexed: 02/06/2023] Open
Abstract
Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers' attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.
Collapse
Affiliation(s)
- Yudong Wang
- Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA; (Y.W.); (B.B.N.); (N.T.); (E.E.E.)
| | - Bharath Babu Nunna
- Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA; (Y.W.); (B.B.N.); (N.T.); (E.E.E.)
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Harvard University, Cambridge, MA 02139, USA
| | - Niladri Talukder
- Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA; (Y.W.); (B.B.N.); (N.T.); (E.E.E.)
| | - Ernst Emmanuel Etienne
- Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA; (Y.W.); (B.B.N.); (N.T.); (E.E.E.)
| | - Eon Soo Lee
- Advanced Energy Systems and Microdevices Laboratory, Department of Mechanical and Industrial Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA; (Y.W.); (B.B.N.); (N.T.); (E.E.E.)
| |
Collapse
|
18
|
Patel H. Blood biocompatibility enhancement of biomaterials by heparin immobilization: a review. Blood Coagul Fibrinolysis 2021; 32:237-247. [PMID: 33443929 DOI: 10.1097/mbc.0000000000001011] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Blood contacting materials are concerned with biocompatibility including thrombus formation, decrease blood coagulation time, hematology, activation of complement system, platelet aggression. Interestingly, recent research suggests that biocompatibility is increasing by incorporating various materials including heparin using different methods. Basic of heparin including uses and complications was mentioned, in which burst release of heparin is major issue. To minimize the problem of biocompatibility and unpredictable heparin release, present review article potentially reviews the reported work and investigates the various immobilization methods of heparin onto biomaterials, such as polymers, metals, and alloys. Detailed explanation of different immobilization methods through different intermediates, activation, incubation method, plasma treatment, irradiations and other methods are also discussed, in which immobilization through intermediates is the most exploitable method. In addition to biocompatibility, other required properties of biomaterials like mechanical and corrosion resistance properties that increase by attachment of heparin are reviewed and discussed in this article.
Collapse
Affiliation(s)
- Himanshu Patel
- Department of Applied Science and Humanities, Pacific School of Engineering, Surat, Gujarat
| |
Collapse
|
19
|
Loss of GPVI and GPIbα contributes to trauma-induced platelet dysfunction in severely injured patients. Blood Adv 2021; 4:2623-2630. [PMID: 32556282 DOI: 10.1182/bloodadvances.2020001776] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 05/17/2020] [Indexed: 11/20/2022] Open
Abstract
Trauma-induced coagulopathy (TIC) is a complex, multifactorial failure of hemostasis that occurs in 25% of severely injured patients and results in a fourfold higher mortality. However, the role of platelets in this state remains poorly understood. We set out to identify molecular changes that may underpin platelet dysfunction after major injury and to determine how they relate to coagulopathy and outcome. We performed a range of hemostatic and platelet-specific studies in blood samples obtained from critically injured patients within 2 hours of injury and collected prospective data on patient characteristics and clinical outcomes. We observed that, although platelet counts were preserved above critical levels, circulating platelets sampled from trauma patients exhibited a profoundly reduced response to both collagen and the selective glycoprotein VI (GPVI) agonist collagen-related peptide, compared with those from healthy volunteers. These responses correlated closely with overall clot strength and mortality. Surface expression of the collagen receptors GPIbα and GPVI was reduced on circulating platelets in trauma patients, with increased levels of the shed ectodomain fragment of GPVI detectable in plasma. Levels of shed GPVI were highest in patients with more severe injuries and TIC. Collectively, these observations demonstrate that platelets experience a loss of GPVI and GPIbα after severe injury and translate into a reduction in the responsiveness of platelets during active hemorrhage. In turn, they are associated with reduced hemostatic competence and increased mortality. Targeting proteolytic shedding of platelet receptors is a potential therapeutic strategy for maintaining hemostatic competence in bleeding and improving the efficacy of platelet transfusions.
Collapse
|
20
|
Kucukal E, Man Y, Gurkan UA, Schmidt BE. Blood Flow Velocimetry in a Microchannel During Coagulation Using Particle Image Velocimetry and Wavelet-Based Optical Flow Velocimetry. J Biomech Eng 2021; 143:1105252. [PMID: 33764427 DOI: 10.1115/1.4050647] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Indexed: 01/05/2023]
Abstract
This article describes novel measurements of the velocity of whole blood flow in a microchannel during coagulation. The blood is imaged volumetrically using a simple optical setup involving a white light source and a microscope camera. The images are processed using particle image velocimetry (PIV) and wavelet-based optical flow velocimetry (wOFV), both of which use images of individual blood cells as flow tracers. Measurements of several clinically relevant parameters such as the clotting time, decay rate, and blockage ratio are computed. The high-resolution wOFV results yield highly detailed information regarding thrombus formation and corresponding flow evolution that is the first of its kind.
Collapse
Affiliation(s)
- E Kucukal
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106
| | - Y Man
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106
| | - Umut A Gurkan
- Warren E. Rupp Associate Professor Department of Mechanical and Aerospace Engineering, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106; Department of Biomedical Engineering, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106
| | - B E Schmidt
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106
| |
Collapse
|
21
|
Hemodynamic analysis for stenosis microfluidic model of thrombosis with refined computational fluid dynamics simulation. Sci Rep 2021; 11:6875. [PMID: 33767279 PMCID: PMC7994556 DOI: 10.1038/s41598-021-86310-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Accepted: 03/11/2021] [Indexed: 11/21/2022] Open
Abstract
Disturbed blood flow has been increasingly recognized for its critical role in platelet aggregation and thrombosis. Microfluidics with hump shaped contractions have been developed to mimic microvascular stenosis and recapitulate the prothrombotic effect of flow disturbance. However the physical determinants of microfluidic hemodynamics are not completely defined. Here, we report a refined computational fluid dynamics (CFD) simulation approach to map the shear rate (γ) and wall shear stress (τ) distribution in the stenotic region at high accuracy. Using ultra-fine meshing with sensitivity verification, our CFD results show that the stenosis level (S) is dominant over the bulk shear rate (γ0) and contraction angle (α) in determining γ and τ distribution at stenosis. In contrast, α plays a significant role in governing the shear rate gradient (γ′) distribution while it exhibits subtle effects on the peak γ. To investigate the viscosity effect, we employ a Generalized Power-Law model to simulate blood flow as a non-Newtonian fluid, showing negligible difference in the γ distribution when compared with Newtonian simulation with water medium. Together, our refined CFD method represents a comprehensive approach to examine microfluidic hemodynamics in three dimensions and guide microfabrication designs. Combining this with hematological experiments promises to advance understandings of the rheological effect in thrombosis and platelet mechanobiology.
Collapse
|
22
|
Mangin PH, Neeves KB, Lam WA, Cosemans JMEM, Korin N, Kerrigan SW, Panteleev MA. In vitro flow-based assay: From simple toward more sophisticated models for mimicking hemostasis and thrombosis. J Thromb Haemost 2021; 19:582-587. [PMID: 34396675 DOI: 10.1111/jth.15143] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 10/12/2020] [Accepted: 10/13/2020] [Indexed: 02/06/2023]
Abstract
In vitro flow-based assays are widely used to investigate the role of platelets and coagulation in hemostasis and thrombosis. Their main advantage over other assays relies on the fact that they integrate blood flow that regulates many aspects of platelet function, including adhesion, activation, and aggregation. Blood flow is also central in the regulation of coagulation through its ability to modulate the local concentrations of coagulation factors within and around thrombi. The most broadly used assay to study thrombus formation consists in perfusing whole blood over immobilized fibrillar collagen through a single channel, which helps to reproduce thrombus formation as it occurs in vivo after vascular injury, with platelets adhering, becoming activated, and forming a mural thrombus. This process can also be studied under conditions of thrombin generation, notably by recalcifying blood collected in sodium citrate. In this manuscript, we briefly discuss the advantages and limits of this broadly used "in vitro thrombus formation model." The main emphasis is on the description of the most recent developments regarding design of new flow models and new techniques, and how these may advance the landscape of in vitro studies into the formation of physiological or pathophysiological thrombi. Challenges linked to mimicking the formation of a hemostatic plug in a healthy vessel or a thrombus in diseased arteries and the complexity of reproducing the various aspects of venous thrombosis are discussed. Future directions are proposed to improve the physiological or pathophysiological relevance of current flow-based assays.
Collapse
Affiliation(s)
- Pierre H Mangin
- INSERM, EFS Grand-Est, BPPS UMR-S1255, FMTS, Université de Strasbourg, Strasbourg, France
| | - Keith B Neeves
- Departments of Bioengineering and Pediatrics, Hemophilia and Thrombosis Center, University of Colorado Denver, Anschutz Medical Campus, Aurora, CO, USA
| | - Wilbur A Lam
- Aflac Cancer and Blood Disorders Center, Department of Pediatrics, Children's Healthcare of Atlanta/Emory University School of Medicine, Atlanta, GA, USA
| | - Judith M E M Cosemans
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Netanel Korin
- Department of Biomedical Engineering Technion, Israel Institute of Technology, Haifa, Israel
| | - Steven W Kerrigan
- School of Pharmacy and Biomolecular Sciences, Royal College of Surgeons in Ireland, Dublin 2, Ireland
| | - Mikhail A Panteleev
- Center for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia
| |
Collapse
|
23
|
DeCortin ME, Brass LF, Diamond SL. Core and shell platelets of a thrombus: A new microfluidic assay to study mechanics and biochemistry. Res Pract Thromb Haemost 2020; 4:1158-1166. [PMID: 33134782 PMCID: PMC7590323 DOI: 10.1002/rth2.12405] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Revised: 04/10/2020] [Accepted: 05/08/2020] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Hemostatic clots have a P-selectin positive platelet core covered with a shell of P-selectin negative platelets. OBJECTIVE To develop a new human blood microfluidic assay to interrogate core/shell mechanics. METHODS A 2-stage assay perfused whole blood over collagen/± tissue factor (TF) for 180 seconds at 100 s-1 wall shear rate, followed by buffer perfusion at either 100 s-1 (venous) or 1000 s-1 (arterial). This microfluidic assay used an extended channel height (120 µm), allowing buffer perfusion well before occlusion. RESULTS Clot growth on collagen stopped immediately with buffer exchange, revealing ~10% reduction in platelet fluorescence intensity (at 100 s-1) and ~30% (at 1000 s-1) by 1200 seconds. Thrombin generation (on collagen/TF) reduced erosion at either buffer flow rate. P-selectin-positive platelets were stable (no erosion) against 1000 s-1, in contrast to P-selectin negative platelets. Thrombin inhibition (with D-Phe-Pro-Arg-CMK) reduced the number of P-selectin-positive platelets and lowered thrombus stability through the reduction of P-selectin-positive platelets. Interestingly, fibrin inhibition (with H-Gly-Pro-Arg-Pro-OH acetate salt) increased the number of P-selectin-positive platelets but did not lower stability, suggesting that fibrin was only in the core region. Thromboxane inhibition reduced P-selectin-positive platelets and caused a nearly 60% reduction of the clot at arterial buffer flow. P2Y1 antagonism reduced clot size and the number of P-selectin-positive platelets and reduced the stability of P-selectin-negative platelets. CONCLUSION The 2-stage assay (extended channel height plus buffer exchange) interrogated platelet stability using human blood. Under all conditions, P-selectin-positive platelets never left the clot.
Collapse
Affiliation(s)
- Michael E. DeCortin
- Department of Chemical and Biomolecular EngineeringInstitute for Medicine and EngineeringUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Lawrence F. Brass
- Department of MedicineUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| | - Scott L. Diamond
- Department of Chemical and Biomolecular EngineeringInstitute for Medicine and EngineeringUniversity of PennsylvaniaPhiladelphiaPennsylvaniaUSA
| |
Collapse
|
24
|
Hu X, Li Y, Li J, Chen H. Effects of altered blood flow induced by the muscle pump on thrombosis in a microfluidic venous valve model. LAB ON A CHIP 2020; 20:2473-2481. [PMID: 32543635 DOI: 10.1039/d0lc00287a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Deep vein thrombosis (DVT) often occurs in the lower limb veins of bedridden patients and greatly reduces the quality of life. The altered blood flow in venous valves induced by the insufficient efficacy of the muscle pump is commonly considered as a main factor. However, it is still a great challenge to observe the altered blood flow in real time, and its role in the formation of thrombi is poorly understood. Here we make a microfluidic venous valve model with flexible leaflets in a deformable channel that can mimic the motion of valves and the compression of vessels by muscle contraction, and identify the stasis and intermittent reflux in the valve pocket generated by the muscle pump. A thrombus forms in the stasis flow, while the intermittent reflux removes the fibrin and inhibits the growth of the thrombus. A flexible microfluidic device that can mimic the motion of valves and the contraction of vessels would have wide applications in the research on cardiovascular diseases.
Collapse
Affiliation(s)
- Xiangyu Hu
- State Key Laboratory of Tribology, Mechanical Engineering Department, Tsinghua University, Beijing, 100084, China.
| | | | | | | |
Collapse
|
25
|
Standing Air Bubble-Based Micro-Hydraulic Capacitors for Flow Stabilization in Syringe Pump-Driven Systems. MICROMACHINES 2020; 11:mi11040396. [PMID: 32290176 PMCID: PMC7231304 DOI: 10.3390/mi11040396] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 03/29/2020] [Accepted: 04/08/2020] [Indexed: 11/17/2022]
Abstract
Unstable liquid flow in syringe pump-driven systems due to the low-speed vibration of the step motor is commonly observed as an unfavorable phenomenon, especially when the flow rate is relatively small. Upon the design of a convenient and cost-efficient microfluidic standing air bubble system, this paper studies the physical principles behind the flow stabilization phenomenon of the bubble-based hydraulic capacitors. A bubble-based hydraulic capacitor consists of three parts: tunable microfluidic standing air bubbles in specially designed crevices on the fluidic channel wall, a proximal pneumatic channel, and porous barriers between them. Micro-bubbles formed in the crevices during liquid flow and the volume of the bubble can be actively controlled by the pneumatic pressure changing in the proximal channel. When there is a flowrate fluctuation from the upstream, the flexible air-liquid interface would deform under the pressure variation, which is analogous to the capacitive charging/discharging process. The theoretical model based on Euler law and the microfluidic equivalent circuit was developed to understand the multiphysical phenomenon. Experimental data characterize the liquid flow stabilization performance of the flow stabilizer with multiple key parameters, such as the number and the size of microbubbles. The developed bubble-based hydraulic capacitor could minimize the flow pulses from syringe pumping by 75.3%. Furthermore, a portable system is demonstrated and compared with a commercial pressure-driven flow system. This study can enhance the understanding of the bubble-based hydraulic capacitors that would be beneficial in microfluidic systems where the precise and stable liquid flow is required.
Collapse
|
26
|
Assessment of antiplatelet therapy response in pediatric patients following cardiac surgery by microfluidic assay. PROGRESS IN PEDIATRIC CARDIOLOGY 2020. [DOI: 10.1016/j.ppedcard.2019.101191] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
27
|
Hartmann J, Murphy M, Dias JD. Viscoelastic Hemostatic Assays: Moving from the Laboratory to the Site of Care-A Review of Established and Emerging Technologies. Diagnostics (Basel) 2020; 10:diagnostics10020118. [PMID: 32098161 PMCID: PMC7167835 DOI: 10.3390/diagnostics10020118] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/17/2020] [Accepted: 02/19/2020] [Indexed: 11/16/2022] Open
Abstract
Viscoelastic-based techniques to evaluate whole blood hemostasis have advanced substantially since they were first developed over 70 years ago but are still based upon the techniques first described by Dr. Hellmut Hartert in 1948. Today, the use of thromboelastography, the method of testing viscoelastic properties of blood coagulation, has moved out of the research laboratory and is now more widespread, used commonly during surgery, in emergency departments, intensive care units, and in labor wards. Thromboelastography is currently a rapidly growing field of technological advancement and is attracting significant investment. This review will first describe the history of the viscoelastic testing and the established first-generation devices, which were developed for use within the laboratory. This review will then describe the next-generation hemostasis monitoring devices, which were developed for use at the site of care for an expanding range of clinical applications. This review will then move on to experimental technologies, which promise to make viscoelastic testing more readily available in a wider range of clinical environments in the endeavor to improve patient care.
Collapse
Affiliation(s)
- Jan Hartmann
- Haemonetics Corporation, Boston, MA 02110, USA;
- Correspondence: ; Tel.: +1-781-348-7396
| | | | - Joao D. Dias
- Haemonetics SA, Signy CH, 1274 Signy-Centre, Switzerland;
| |
Collapse
|
28
|
Jigar Panchal H, Kent NJ, Knox AJS, Harris LF. Microfluidics in Haemostasis: A Review. Molecules 2020; 25:E833. [PMID: 32075008 PMCID: PMC7070452 DOI: 10.3390/molecules25040833] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/11/2020] [Accepted: 02/12/2020] [Indexed: 12/17/2022] Open
Abstract
Haemostatic disorders are both complex and costly in relation to both their treatment and subsequent management. As leading causes of mortality worldwide, there is an ever-increasing drive to improve the diagnosis and prevention of haemostatic disorders. The field of microfluidic and Lab on a Chip (LOC) technologies is rapidly advancing and the important role of miniaturised diagnostics is becoming more evident in the healthcare system, with particular importance in near patient testing (NPT) and point of care (POC) settings. Microfluidic technologies present innovative solutions to diagnostic and clinical challenges which have the knock-on effect of improving health care and quality of life. In this review, both advanced microfluidic devices (R&D) and commercially available devices for the diagnosis and monitoring of haemostasis-related disorders and antithrombotic therapies, respectively, are discussed. Innovative design specifications, fabrication techniques, and modes of detection in addition to the materials used in developing micro-channels are reviewed in the context of application to the field of haemostasis.
Collapse
Affiliation(s)
- Heta Jigar Panchal
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| | - Nigel J Kent
- engCORE, Faculty of Engineering, Institute of Technology Carlow, Kilkenny Road, Carlow R93 V960, Ireland;
| | - Andrew J S Knox
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| | - Leanne F Harris
- School of Biological and Health Sciences, Technological University Dublin (TU Dublin) - City Campus, Kevin Street, Dublin D08 NF82, Ireland; (H.J.P.); (A.J.S.K.)
| |
Collapse
|
29
|
Mena SE, Li Y, McCormick J, McCracken B, Colmenero C, Ward K, Burns MA. A droplet-based microfluidic viscometer for the measurement of blood coagulation. BIOMICROFLUIDICS 2020; 14:014109. [PMID: 31966348 PMCID: PMC6968952 DOI: 10.1063/1.5128255] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Accepted: 01/03/2020] [Indexed: 05/20/2023]
Abstract
A continuous microfluidic viscometer is used to measure blood coagulation. The viscometer operates by flowing oil and blood into a cross section where droplets are generated. At a set pressure, the length of the droplets is inversely proportional to the viscosity of the blood sample being delivered. Because blood viscosity increases during coagulation as the blood changes from a liquid to a solid gel, the device allows to monitor coagulation by simply measuring the drop length. Experiments with swine blood were carried out in its native state and with the addition of coagulation activators and inhibitors. The microfluidic viscometer detected an earlier initiation of the coagulation process with the activator and a later initiation with the inhibitor compared to their corresponding controls. The results from the viscometer were also compared with the clinical method of thromboelastography (TEG), which was performed concurrently for the same samples. The time to initiation of coagulation in the microfluidic viscometer was correlated with the reaction time in TEG. Additionally, the total time for the measurement of clot strengthening in TEG correlated with the time for the maximum viscosity observed in the microfluidic viscometer. The microfluidic viscometer measured changes in viscosity due to coagulation faster than TEG detected the clot formation. The present viscometer is a simple technology that can be used to further study the entire coagulation process.
Collapse
Affiliation(s)
- Sarah E. Mena
- Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Yunzi Li
- Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Joseph McCormick
- Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | | | | | | |
Collapse
|
30
|
Mohammadi Aria M, Erten A, Yalcin O. Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing. Front Bioeng Biotechnol 2019; 7:395. [PMID: 31921804 PMCID: PMC6917661 DOI: 10.3389/fbioe.2019.00395] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 11/21/2019] [Indexed: 12/24/2022] Open
Abstract
In recent years, blood coagulation monitoring has become crucial to diagnosing causes of hemorrhages, developing anticoagulant drugs, assessing bleeding risk in extensive surgery procedures and dialysis, and investigating the efficacy of hemostatic therapies. In this regard, advanced technologies such as microfluidics, fluorescent microscopy, electrochemical sensing, photoacoustic detection, and micro/nano electromechanical systems (MEMS/NEMS) have been employed to develop highly accurate, robust, and cost-effective point of care (POC) devices. These devices measure electrochemical, optical, and mechanical parameters of clotting blood. Which can be correlated to light transmission/scattering, electrical impedance, and viscoelastic properties. In this regard, this paper discusses the working principles of blood coagulation monitoring, physical and sensing parameters in different technologies. In addition, we discussed the recent progress in developing nanomaterials for blood coagulation detection and treatments which opens up new area of controlling and monitoring of coagulation at the same time in the future. Moreover, commercial products, future trends/challenges in blood coagulation monitoring including novel anticoagulant therapies, multiplexed sensing platforms, and the application of artificial intelligence in diagnosis and monitoring have been included.
Collapse
Affiliation(s)
| | - Ahmet Erten
- Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkey
| | - Ozlem Yalcin
- Graduate School of Biomedical Sciences and Engineering, Koc University, Sariyer, Turkey
- Department of Physiology, Koc University School of Medicine, Koc University, Sariyer, Turkey
| |
Collapse
|
31
|
Kim D, Bresette C, Liu Z, Ku DN. Occlusive thrombosis in arteries. APL Bioeng 2019; 3:041502. [PMID: 31768485 PMCID: PMC6863762 DOI: 10.1063/1.5115554] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Accepted: 10/16/2019] [Indexed: 12/18/2022] Open
Abstract
Thrombus formation in major arteries is life threatening. In this review article, we discuss how an arterial thrombus can form under pathologically high shear stresses, with bonding rates estimated to be the fastest Kon values in biochemistry. During occlusive thrombosis in arteries, the growth rate of the thrombus explodes to capture a billion platelets in about 10 min. Close to 100% of all platelets passing the thrombus are captured by long von Willebrand factor (vWF) strands that quickly form tethered nets. The nets grow in patches where shear stress is high, and the local concentration of vWF is elevated due to α-granule release by previously captured platelets. This rapidly formed thrombus has few red blood cells and so has a white appearance and is much stronger and more porous than clots formed through coagulation. Understanding and modeling the biophysics of this event can predict totally new approaches to prevent and treat heart attacks and strokes.
Collapse
Affiliation(s)
- Dongjune Kim
- GWW School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0363, USA
| | - Christopher Bresette
- GWW School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0363, USA
| | - Zixiang Liu
- GWW School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0363, USA
| | - David N Ku
- GWW School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0363, USA
| |
Collapse
|
32
|
Provenzale I, Brouns SLN, van der Meijden PEJ, Swieringa F, Heemskerk JWM. Whole Blood Based Multiparameter Assessment of Thrombus Formation in Standard Microfluidic Devices to Proxy In Vivo Haemostasis and Thrombosis. MICROMACHINES 2019; 10:mi10110787. [PMID: 31744132 PMCID: PMC6915499 DOI: 10.3390/mi10110787] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 11/13/2019] [Accepted: 11/14/2019] [Indexed: 02/06/2023]
Abstract
Microfluidic assays are versatile tests which, using only small amounts of blood, enable high throughput analyses of platelet function in several minutes. In combination with fluorescence microscopy, these flow tests allow real-time visualisation of platelet activation with the possibility of examining combinatorial effects of wall shear rate, coagulation and modulation by endothelial cells. In particular, the ability to use blood and blood cells from healthy subjects or patients makes this technology promising, both for research and (pre)clinical diagnostic purposes. In the present review, we describe how microfluidic devices are used to assess the roles of platelets in thrombosis and haemostasis. We place emphasis on technical aspects and on experimental designs that make the concept of "blood-vessel-component-on-a-chip" an attractive, rapidly developing technology for the study of the complex biological processes of blood coagulability in the presence of flow.
Collapse
Affiliation(s)
- Isabella Provenzale
- Correspondence: (I.P.); (J.W.M.H.); Tel.: +31-43-3881671 or +31-43-3881674 (J.W.M.H.)
| | | | | | | | - Johan W. M. Heemskerk
- Correspondence: (I.P.); (J.W.M.H.); Tel.: +31-43-3881671 or +31-43-3881674 (J.W.M.H.)
| |
Collapse
|
33
|
Methods for measurement of platelet function in the assessment of nonclinical drug safety and implications for translatability. CURRENT OPINION IN TOXICOLOGY 2019. [DOI: 10.1016/j.cotox.2019.10.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
34
|
Griffin MT, Kim D, Ku DN. Shear-induced platelet aggregation: 3D-grayscale microfluidics for repeatable and localized occlusive thrombosis. BIOMICROFLUIDICS 2019; 13:054106. [PMID: 31592301 PMCID: PMC6773594 DOI: 10.1063/1.5113508] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 09/13/2019] [Indexed: 05/20/2023]
Abstract
Atherothrombosis leads to complications of myocardial infarction and stroke as a result of shear-induced platelet aggregation (SIPA). Clinicians and researchers may benefit from diagnostic and benchtop microfluidic assays that assess the thrombotic activity of an individual. Currently, there are several different proposed point-of-care diagnostics and microfluidic thrombosis assays with different design parameters and end points. The microfluidic geometry, surface coatings, and anticoagulation may strongly influence the precision of these assays. Variability in selected end points also persists, leading to ambiguous results. This study aims to assess the effects of three physiologically relevant extrinsic design factors on the variability of a single end point to provide a quantified rationale for design parameter and end-point standardization. Using a design of experiments approach, we show that the methods of channel fabrication and collagen surface coating significantly impact the variability of occlusion time from porcine whole blood, while anticoagulant selection between heparin and citrate did not significantly impact the variability. No factor was determined to significantly impact the mean occlusion time within the assay. Occlusive thrombus was found to consistently form in the first third (333 μm) of the high shear zone and not in the shear gradient regions. The selection of these factors in the design of point-of-care diagnostics and experimental SIPA assays may lead to increased precision and specificity in high shear thrombosis studies.
Collapse
Affiliation(s)
| | - Dongjune Kim
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30318, USA
| | - David N. Ku
- Author to whom correspondence should be addressed:
| |
Collapse
|
35
|
Lee H, Na W, Lee BK, Lim CS, Shin S. Recent advances in microfluidic platelet function assays: Moving microfluidics into clinical applications. Clin Hemorheol Microcirc 2019; 71:249-266. [PMID: 30584134 DOI: 10.3233/ch-189416] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The analysis of platelet aggregation and thrombosis kinetics has significantly advanced with progress in microfluidic technology. However, the results of platelet aggregation tests do not fully reflect the observed clinical outcomes. To address the present unmet clinical needs, the basic but essential biology of platelets should be reconsidered in relation to the characteristics of microfluidic systems employed for platelet tests. To this end, the present article provides an overview of commercially available point of care devices and focuses on recent microfluidic studies, describing their measurement principles. We critically discuss the characteristics of the microfluidics systems used to evaluate the complex processes underlying platelet aggregation, and that are specifically designed to mimic the pathophysiological environment of blood vessels, including hemodynamic factors as well as blood vessel injury. To this end, we summarize unsolved issues related to the application of platelet function tests based on microfluidics. Overall, we confirm that platelet function tests based on microfluidics provide a versatile platform that encompasses a variety of basic research, as well as clinical diagnostic applications.
Collapse
Affiliation(s)
- Hoyoon Lee
- Department of Mechanical Engineering, Korea University, Seoul, Korea
| | - Wonwhi Na
- Engineering Research Center for Biofluid Biopsy, Korea University, Seoul, Korea
| | - Byoung-Kwon Lee
- Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University Medical College, Seoul, Korea
| | - Chae-Seung Lim
- Department of Laboratory Medicine, Guro Hospital, Korea University, Seoul, Korea
| | - Sehyun Shin
- Department of Mechanical Engineering, Korea University, Seoul, Korea.,Engineering Research Center for Biofluid Biopsy, Korea University, Seoul, Korea
| |
Collapse
|
36
|
Sotiri I, Robichaud M, Lee D, Braune S, Gorbet M, Ratner BD, Brash JL, Latour RA, Reviakine I. BloodSurf 2017: News from the blood-biomaterial frontier. Acta Biomater 2019; 87:55-60. [PMID: 30660001 DOI: 10.1016/j.actbio.2019.01.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Revised: 01/09/2019] [Accepted: 01/14/2019] [Indexed: 12/26/2022]
Abstract
From stents and large-diameter vascular grafts, to mechanical heart valves and blood pumps, blood-contacting devices are enjoying significant clinical success owing to the application of systemic antiplatelet and anticoagulation therapies. On the contrary, research into material and device hemocompatibility aimed at alleviating the need for systemic therapies has suffered a decline. This research area is undergoing a renaissance fueled by recent fundamental insights into coagulation and inflammation that are offering new avenues of investigation, the growing recognition of the limitations facing existing therapeutic approaches, and the severity of the cardiovascular disorders epidemic. This Opinion article discusses clinical needs for hemocompatible materials and the emerging research directions for fulfilling those needs. Based on the 2017 BloodSurf conference that brought together clinicians, scientists, and engineers from academia, industry, and regulatory bodies, its purpose is to draw the attention of the wider clinical and scientific community to stimulate further growth. STATEMENT OF SIGNIFICANCE: The article highlights recent fundamental insights into coagulation, inflammation, and blood-biomaterial interactions that are fueling a renaissance in the field of material hemocompatibility. It will be useful for clinicians, scientists, engineers, representatives of industry and regulatory bodies working on the problem of developing hemocompatible materials and devices for treating cardiovascular disorders.
Collapse
|
37
|
Contractile forces in platelet aggregates under microfluidic shear gradients reflect platelet inhibition and bleeding risk. Nat Commun 2019; 10:1204. [PMID: 30867419 PMCID: PMC6416331 DOI: 10.1038/s41467-019-09150-9] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 02/13/2019] [Indexed: 12/21/2022] Open
Abstract
Platelets contract forcefully after their activation, contributing to the strength and stability of platelet aggregates and fibrin clots during blood coagulation. Viscoelastic approaches can be used to assess platelet-induced clot strengthening, but they require thrombin and fibrin generation and are unable to measure platelet forces directly. Here, we report a rapid, microfluidic approach for measuring the contractile force of platelet aggregates for the detection of platelet dysfunction. We find that platelet forces are significantly reduced when blood samples are treated with inhibitors of myosin, GPIb-IX-V, integrin αIIbβ3, P2Y12, or thromboxane generation. Clinically, we find that platelet forces are measurably lower in cardiology patients taking aspirin. We also find that measuring platelet forces can identify Emergency Department trauma patients who subsequently require blood transfusions. Together, these findings indicate that microfluidic quantification of platelet forces may be a rapid and useful approach for monitoring both antiplatelet therapy and traumatic bleeding risk. Platelet aggregates generate contractile forces that contribute to their cohesion and adhesion. Here, Ting et al. develop a microfluidic device to measure contractile forces generated by platelet aggregates, and find it can detect the response of platelets to pharmacological agents and predict bleeding risk in trauma patients.
Collapse
|
38
|
Kang YJ, Lee SJ. In vitro and ex vivo measurement of the biophysical properties of blood using microfluidic platforms and animal models. Analyst 2019; 143:2723-2749. [PMID: 29740642 DOI: 10.1039/c8an00231b] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Haemorheologically impaired microcirculation, such as blood clotting or abnormal blood flow, causes interrupted blood flows in vascular networks. The biophysical properties of blood, including blood viscosity, blood viscoelasticity, haematocrit, red blood bell (RBC) aggregation, erythrocyte sedimentation rate and RBC deformability, have been used to monitor haematological diseases. In this review, we summarise several techniques for measuring haemorheological properties, such as blood viscosity, RBC deformability and RBC aggregation, using in vitro microfluidic platforms. Several methodologies for the measurement of haemorheological properties with the assistance of an extracorporeal rat bypass loop are also presented. We briefly discuss several emerging technologies for continuous, long-term, multiple measurements of haemorheological properties under in vitro or ex vivo conditions.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, Gwangju, Republic of Korea
| | | |
Collapse
|
39
|
Chen L, Huang R, Zhu D, Wang Y, Mehjabin R, Li Y, Liao L, He L, Zhu Z, Wang Y. Cloning of six serpin genes and their responses to GCRV infection in grass carp (Ctenopharyngodon idella). FISH & SHELLFISH IMMUNOLOGY 2019; 86:93-100. [PMID: 30439497 DOI: 10.1016/j.fsi.2018.11.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Revised: 09/29/2018] [Accepted: 11/03/2018] [Indexed: 06/09/2023]
Abstract
Grass carp, an economically important aquaculture fish, is very sensitive to Grass Carp Reovirus (GCRV). Haemorrhagic disease caused by GCRV infection can cause large-scale death of first-year grass carp, thereby severely restricting the intensive culture. Serpins (serine protease inhibitors) belong to the protease inhibitor gene family and are involved in numerous physiological and pathological processes, particularly coagulation and anticoagulation. Reports on grass carp serpins are scarce. Thus, we cloned six grass carp serpin genes (serpinb1, serpinc1, serpind1, serpinf1, serpinf2b and serping1) in this study. Molecular evolution showed that serpins between grass carp and zebrafish or carp are the closest relatives. SERPIN domains in these 6 serpins and reactive centre loop (RCL) along with their cleavage sites of 5 serpins (serpinb1, serpinc1, serpind1, serpinf2b and serping1) were predicted. Real-time quantitative PCR (RT-qPCR) showed that these serpins displayed tissue significance. Among them, serpinc1, serpind1, serpinf2b and serping1 had the highest expression levels in the liver. After GCRV infection, RT-qPCR showed that the liver-enriched serpins were significantly changed. Key procoagulant factor genes (kng-1, f2, f3a, f3b and f7) and anticoagulant genes (tpa, plg, thbd, proc and pros) also showed significant changes on the mRNA level. Comprehensive comparative analysis showed that the up-regulated expression of key clotting factor genes was more prominent than that of main anti-coagulation factor genes. Thus, the function of coagulation may be more dominant in grass carp during the GCRV infection, which may cause overproduction of thrombi. The serpins were involved in GCRV infection and liver-enriched serpins participate in the interaction between coagulation and anticoagulation. This study provided new insights into further research on the biological functions of grass carp serpins and clarifying the molecular mechanism of GCRV affecting the homeostasis of grass carp blood environment.
Collapse
Affiliation(s)
- Liangming Chen
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Rong Huang
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China.
| | - Denghui Zhu
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | | | - Rumana Mehjabin
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yongming Li
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China
| | - Lanjie Liao
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China
| | - Libo He
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China
| | - Zuoyan Zhu
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China
| | - Yaping Wang
- State Key Laboratory of Freshwater Ecology and Biotechnology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, 430072, China.
| |
Collapse
|
40
|
Brass LF, Tomaiuolo M, Welsh J, Poventud-Fuentes I, Zhu L, Diamond SL, Stalker TJ. Hemostatic Thrombus Formation in Flowing Blood. Platelets 2019. [DOI: 10.1016/b978-0-12-813456-6.00020-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
41
|
Lawson PJ, Moore HB, Moore EE, Gerich ME, Stettler GR, Banerjee A, Schulick RD, Nydam TL. Microfluidics contrasted to thrombelastography: perplexities in defining hypercoagulability. J Surg Res 2018; 231:54-61. [PMID: 30278969 DOI: 10.1016/j.jss.2018.04.059] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 04/07/2018] [Accepted: 04/24/2018] [Indexed: 01/22/2023]
Abstract
BACKGROUND Elevated clot strength (maximum amplitude [MA]) measured by thrombelastography (TEG) is associated with thrombotic complications. However, it remains unclear how MA translates to thrombotic risks, as this measurement is independent of time, blood flow, and clot degradation. We hypothesize that under flow conditions, increased clot strength correlates to time-dependent measurements of coagulation and resistance to fibrinolysis. MATERIALS AND METHODS Surgical patients at high risk of thrombotic complications were analyzed with TEG and total thrombus-formation analysis system (T-TAS). TEG hypercoagulability was defined as an r <10.2 min, angle >59, MA >66 or LY30 <0.2% (based off of healthy control data, n = 141). The T-TAS AR and PL chips were used to measure clotting at arterial shear rates. T-TAS measurements include occlusion start time, occlusion time (OT), occlusion speed (OSp), and total clot generation (area under the curve). These measurements were correlated to TEG indices (R time, angle, MA, and LY30). Both T-TAS and TEG assays were challenged with tissue plasminogen activator (t-PA) to assess clot resistance to fibrinolysis. RESULTS Thirty subjects were analyzed, including five controls. TEG-defined hypercoagulability by MA was detected in 52% of the inflammatory bowel disease/cancer patients; 0% was detected in the controls. There were no TEG measurements that significantly correlated with T-TAS AR and PL chip. However, in the presence of t-PA, T-TAS AR determined OSp to have an inverse relationship with TEG angle (-0.477, P = 0.012) and LY30 (-0.449, P = 0.019), and a positive correlation with R time (0.441 P = 0.021). In hypercoagulability determined by TEG MA, T-TAS PL had a significantly reduced OT (4:07 versus 6:27 min, P = 0.043). In hypercoagulability defined by TEG LY30, T-TAS PL had discordant findings, with a significantly prolonged OT (6:36 versus 4:30 min, P = 0.044) and a slower OSp (10.5 versus 19.0 kPa/min, P = 0.030). CONCLUSIONS Microfluidic coagulation assessment with T-TAS has an overall poor correlation with most TEG measurements in a predominantly hypercoagulable patient population, except in the presence of t-PA. The one anticipated finding was an elevated MA having a shorter time to platelet-mediated microfluidic occlusion, supporting the role of platelets and hypercoagulability. However, hypercoagulability defined by LY30 had opposing results in which a low LY30 was associated with a longer PL time to occlusion and slower OSp. These discordant findings warrant ongoing investigation into the relationship between clot strength and fibrinolysis under different flow conditions.
Collapse
Affiliation(s)
- Peter J Lawson
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado
| | - Hunter B Moore
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado.
| | - Ernest E Moore
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado; Denver Health Medical Center, Denver, Colorado
| | - Mark E Gerich
- Division of Gastroenterology and Hepatology, Department of Medicine, University of Colorado School of Medicine, Aurora, Colorado
| | - Gregory R Stettler
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado
| | - Anirban Banerjee
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado
| | - Richard D Schulick
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado
| | - Trevor L Nydam
- Department of Surgery, University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
42
|
Xu S, Xu Z, Kim OV, Litvinov RI, Weisel JW, Alber M. Model predictions of deformation, embolization and permeability of partially obstructive blood clots under variable shear flow. J R Soc Interface 2018; 14:rsif.2017.0441. [PMID: 29142014 DOI: 10.1098/rsif.2017.0441] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Accepted: 10/19/2017] [Indexed: 01/20/2023] Open
Abstract
Thromboembolism, one of the leading causes of morbidity and mortality worldwide, is characterized by formation of obstructive intravascular clots (thrombi) and their mechanical breakage (embolization). A novel two-dimensional multi-phase computational model is introduced that describes active interactions between the main components of the clot, including platelets and fibrin, to study the impact of various physiologically relevant blood shear flow conditions on deformation and embolization of a partially obstructive clot with variable permeability. Simulations provide new insights into mechanisms underlying clot stability and embolization that cannot be studied experimentally at this time. In particular, model simulations, calibrated using experimental intravital imaging of an established arteriolar clot, show that flow-induced changes in size, shape and internal structure of the clot are largely determined by two shear-dependent mechanisms: reversible attachment of platelets to the exterior of the clot and removal of large clot pieces. Model simulations predict that blood clots with higher permeability are more prone to embolization with enhanced disintegration under increasing shear rate. In contrast, less permeable clots are more resistant to rupture due to shear rate-dependent clot stiffening originating from enhanced platelet adhesion and aggregation. These results can be used in future to predict risk of thromboembolism based on the data about composition, permeability and deformability of a clot under specific local haemodynamic conditions.
Collapse
Affiliation(s)
- Shixin Xu
- Department of Mathematics, Division of Clinical Sciences, School of Medicine, University of California, Riverside, CA 92521, USA
| | - Zhiliang Xu
- Department of Applied and Computational Mathematics and Statistics, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Oleg V Kim
- Department of Mathematics, Division of Clinical Sciences, School of Medicine, University of California, Riverside, CA 92521, USA.,Department of Cell and Developmental Biology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Rustem I Litvinov
- Department of Cell and Developmental Biology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.,Department of Biochemistry and Biotechnology, Kazan Federal University, Kazan 420008, Russian Federation
| | - John W Weisel
- Department of Cell and Developmental Biology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Mark Alber
- Department of Mathematics, Division of Clinical Sciences, School of Medicine, University of California, Riverside, CA 92521, USA .,Department of Internal Medicine, Division of Clinical Sciences, School of Medicine, University of California, Riverside, CA 92521, USA.,Department of Applied and Computational Mathematics and Statistics, University of Notre Dame, Notre Dame, IN 46556, USA.,Department of Medicine, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| |
Collapse
|
43
|
Griffin MT, Zhu Y, Liu Z, Aidun CK, Ku DN. Inhibition of high shear arterial thrombosis by charged nanoparticles. BIOMICROFLUIDICS 2018; 12:042210. [PMID: 29887934 PMCID: PMC5973895 DOI: 10.1063/1.5025349] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Accepted: 05/07/2018] [Indexed: 05/02/2023]
Abstract
Platelet accumulation under high shear rates at the site of atherosclerotic plaque rupture leads to myocardial infarction and stroke. Current antiplatelet therapies remain ineffective within a large percentage of the population, while presenting significant risks for bleeding. We explore a novel way to inhibit arterial thrombus formation by biophysical means without the use of platelet inactivating drugs. Our computational multi-scale dynamics model has predicted that charged particles of a specific size may entangle von Willebrand Factor (vWF) polymers and reduce the amount of elongation at high shear rates. We tested this hypothesis experimentally for negatively charged nanoparticles (CNP) to inhibit arterial thrombus formation. CNP of a particular size and charge inhibited thrombus formation, with a 10-fold peak inhibition over control conditions of thrombotic occlusion. Particles of differing material composition, size, and charge had little effect as predicted by computational studies. Surprisingly, the dose response curve was not sigmoidal, but exhibited a peak at 1.5 CNP:vWF proteins, which was not predicted by the model. This study describes a new antithrombotic agent that may have a different mechanism of action than current pharmaceutical therapies.
Collapse
Affiliation(s)
| | - Yuanzheng Zhu
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, USA
| | - Zixiang Liu
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, USA
| | | | - David N. Ku
- Author to whom correspondence should be addressed:
| |
Collapse
|
44
|
Lee YK, Porter C, Diamond SL, Crocker JC, Sinno T. Deposition of sticky spheres in channel flow: Modeling of surface coverage evolution requires accurate sphere-sphere collision hydrodynamics. J Colloid Interface Sci 2018; 530:383-393. [PMID: 29982030 DOI: 10.1016/j.jcis.2018.06.097] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 06/28/2018] [Accepted: 06/29/2018] [Indexed: 11/17/2022]
Abstract
We analyzed the role of hydrodynamic interactions in a microfluidic channel flow containing a dilute suspension of micron-scale colloidal spheres (0.03%, 0.1%, 0.3% volume fraction) engineered to adhere onto a collector patch on the channel wall at wall shear rates of 9.3-930 s-1. Particle-wall adhesion was mediated by single-stranded DNA oligomers grafted onto the spheres and the glass channel wall, producing well-defined interactions via DNA strand base pairing. Particle positions in the flow were evolved using Brownian dynamics simulations in which hydrodynamic interactions between moving particles and the channel walls and/or adhered particles were computed off-line using a series of local simulations that explicitly resolve the fluid flow at the particle scale. By systematically varying the nature of hydrodynamic interactions captured in the Brownian dynamics simulations, we find that the interactions between moving and adhered particles represents the single most important physical element in such models. Once captured sufficiently accurately, the resulting models are able to predict coarse variables such as the overall particle coverage evolution, as well as more subtle characteristics, such as the microstructural distribution of the adhered particles.
Collapse
Affiliation(s)
- Young Ki Lee
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Christopher Porter
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Scott L Diamond
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - John C Crocker
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Talid Sinno
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
45
|
Szydzik C, Brazilek RJ, Khoshmanesh K, Akbaridoust F, Knoerzer M, Thurgood P, Muir I, Marusic I, Nandurkar H, Mitchell A, Nesbitt WS. Elastomeric microvalve geometry affects haemocompatibility. LAB ON A CHIP 2018; 18:1778-1792. [PMID: 29789838 DOI: 10.1039/c7lc01320e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This paper reports on the parameters that determine the haemocompatibility of elastomeric microvalves for blood handling in microfluidic systems. Using a comprehensive investigation of blood function, we describe a hierarchy of haemocompatibility as a function of microvalve geometry and identify a "normally-closed" v-gate pneumatic microvalve design that minimally affects blood plasma fibrinogen and von Willebrand factor composition, minimises effects on erythrocyte structure and function, and limits effects on platelet activation and aggregation, while facilitating rapid switching control for blood sample delivery. We propose that the haemodynamic profile of valve gate geometries is a significant determinant of platelet-dependent biofouling and haemocompatibility. Overall our findings suggest that modification of microvalve gate geometry and consequently haemodynamic profile can improve haemocompatibility, while minimising the requirement for chemical or protein modification of microfluidic surfaces. This biological insight and approach may be harnessed to inform future haemocompatible microfluidic valve and component design, and is an advance towards lab-on-chip automation for blood based diagnostic systems.
Collapse
Affiliation(s)
- Crispin Szydzik
- School of Engineering, RMIT University, 124 La Trobe Street, Melbourne, Victoria 3000, Australia.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Zilberman-Rudenko J, McCarty OJT. Utility and development of microfluidic platforms for platelet research. Platelets 2018; 28:425-426. [PMID: 28700317 DOI: 10.1080/09537104.2017.1325187] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
| | - Owen J T McCarty
- a Biomedical Engineering, School of Medicine, Oregon Health & Science University , Portland , OR , USA.,b Division of Hematology /Medical Oncology , School of Medicine, Oregon Health & Science University , Portland , OR , USA
| |
Collapse
|
47
|
Pujos JS, Reyssat M, Le Goff A. Experimental and numerical study of platelets rolling on a von Willebrand factor-coated surface. Med Eng Phys 2018; 55:25-33. [PMID: 29599066 DOI: 10.1016/j.medengphy.2018.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 02/26/2018] [Accepted: 03/13/2018] [Indexed: 11/26/2022]
Abstract
Blood platelets circulate in the blood and adhere to wounded vessels to initiate coagulation and healing. The first step of this process is the capture of flowing platelets by adhesive molecules located at the wounded vessel wall. In this article, we study the transport of fixed blood platelets in a microfluidic channel coated with von Willebrand factor (vWF), a large multimeric protein expressed by endothelial cells in the vicinity of wounds. We measure the number of platelets adsorbed at the channel surface as a function of both time and space. Experimental results are compared with a new transport model. We show that transverse diffusion is an important feature of our model, while the rolling behaviour of the bounded platelets can be neglected.
Collapse
Affiliation(s)
- Justine S Pujos
- ESPCI Paris, PSL Research University, CNRS UMR 7083 Gulliver, 10 rue Vauquelin, 75231 Paris Cedex 05, France
| | - Mathilde Reyssat
- ESPCI Paris, PSL Research University, CNRS UMR 7083 Gulliver, 10 rue Vauquelin, 75231 Paris Cedex 05, France
| | - Anne Le Goff
- ESPCI Paris, PSL Research University, CNRS UMR 7083 Gulliver, 10 rue Vauquelin, 75231 Paris Cedex 05, France; Sorbonne Universités, Université de Technologie de Compiègne, CNRS UMR 7338 Biomécanique et Bioingénierie, Centre de recherche Royallieu, CS 60 319, Compiègne cedex 60 203, France.
| |
Collapse
|
48
|
Brouns SLN, van Geffen JP, Heemskerk JWM. High-throughput measurement of human platelet aggregation under flow: application in hemostasis and beyond. Platelets 2018. [DOI: 10.1080/09537104.2018.1447660] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
- Sanne L. N. Brouns
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Johanna P. van Geffen
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Johan W. M. Heemskerk
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| |
Collapse
|
49
|
Charmet J, Arosio P, Knowles TP. Microfluidics for Protein Biophysics. J Mol Biol 2018; 430:565-580. [DOI: 10.1016/j.jmb.2017.12.015] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 12/19/2017] [Accepted: 12/20/2017] [Indexed: 01/09/2023]
|
50
|
A microengineered vascularized bleeding model that integrates the principal components of hemostasis. Nat Commun 2018; 9:509. [PMID: 29410404 PMCID: PMC5802762 DOI: 10.1038/s41467-018-02990-x] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 01/11/2018] [Indexed: 01/12/2023] Open
Abstract
Hemostasis encompasses an ensemble of interactions among platelets, coagulation factors, blood cells, endothelium, and hemodynamic forces, but current assays assess only isolated aspects of this complex process. Accordingly, here we develop a comprehensive in vitro mechanical injury bleeding model comprising an "endothelialized" microfluidic system coupled with a microengineered pneumatic valve that induces a vascular "injury". With perfusion of whole blood, hemostatic plug formation is visualized and "in vitro bleeding time" is measured. We investigate the interaction of different components of hemostasis, gaining insight into several unresolved hematologic issues. Specifically, we visualize and quantitatively demonstrate: the effect of anti-platelet agent on clot contraction and hemostatic plug formation, that von Willebrand factor is essential for hemostasis at high shear, that hemophilia A blood confers unstable hemostatic plug formation and altered fibrin architecture, and the importance of endothelial phosphatidylserine in hemostasis. These results establish the versatility and clinical utility of our microfluidic bleeding model.
Collapse
|