1
|
Advances and Applications of Metal-Organic Frameworks (MOFs) in Emerging Technologies: A Comprehensive Review. GLOBAL CHALLENGES (HOBOKEN, NJ) 2024; 8:2300244. [PMID: 38356684 PMCID: PMC10862192 DOI: 10.1002/gch2.202300244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 08/19/2023] [Indexed: 02/16/2024]
Abstract
Metal-organic frameworks (MOFs) that are the wonder material of the 21st century consist of metal ions/clusters coordinated to organic ligands to form one- or more-dimensional porous structures with unprecedented chemical and structural tunability, exceptional thermal stability, ultrahigh porosity, and a large surface area, making them an ideal candidate for numerous potential applications. In this work, the recent progress in the design and synthetic approaches of MOFs and explore their potential applications in the fields of gas storage and separation, catalysis, magnetism, drug delivery, chemical/biosensing, supercapacitors, rechargeable batteries and self-powered wearable sensors based on piezoelectric and triboelectric nanogenerators are summarized. Lastly, this work identifies present challenges and outlines future opportunities in this field, which can provide valuable references.
Collapse
|
2
|
Microfluidic-based blood immunoassays. J Pharm Biomed Anal 2023; 228:115313. [PMID: 36868029 DOI: 10.1016/j.jpba.2023.115313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 02/09/2023] [Accepted: 02/22/2023] [Indexed: 02/26/2023]
Abstract
Microfluidics enables the integration of whole protocols performed in a laboratory, including sample loading, reaction, extraction, and measurement steps on a single system, which offers significant advantages thanks to small-scale operation combined with precise fluid control. These include providing efficient transportation mechanisms and immobilization, reduced sample and reagent volumes, fast analysis and response times, lower power requirements, lower cost and disposability, improved portability and sensitivity, and greater integration and automation capability. Immunoassay is a specific bioanalytical method based on the interaction of antigens and antibodies, which is utilized to detect bacteria, viruses, proteins, and small molecules in several areas such as biopharmaceutical analysis, environmental analysis, food safety, and clinical diagnostics. Because of the advantages of both techniques, the combination of immunoassays and microfluidic technology is considered one of the most potential biosensor systems for blood samples. This review presents the current progress and important developments in microfluidic-based blood immunoassays. After providing several basic information about blood analysis, immunoassays, and microfluidics, the review points out in-depth information about microfluidic platforms, detection techniques, and commercial microfluidic blood immunoassay platforms. In conclusion, some thoughts and future perspectives are provided.
Collapse
|
3
|
RapidET: a MEMS-based platform for label-free and rapid demarcation of tumors from normal breast biopsy tissues. MICROSYSTEMS & NANOENGINEERING 2022; 8:1. [PMID: 35087680 PMCID: PMC8761751 DOI: 10.1038/s41378-021-00337-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 11/07/2021] [Accepted: 11/28/2021] [Indexed: 05/09/2023]
Abstract
The rapid and label-free diagnosis of malignancies in ex vivo breast biopsy tissues has significant utility in pathology laboratories and operating rooms. We report a MEMS-based platform integrated with microchips that performs phenotyping of breast biopsy tissues using electrothermal sensing. The microchip, fabricated on a silicon substrate, incorporates a platinum microheater, interdigitated electrodes (IDEs), and resistance temperature detectors (RTDs) as on-chip sensing elements. The microchips are integrated onto the platform using a slide-fit contact enabling quick replacement for biological measurements. The bulk resistivity (ρ B ), surface resistivity (ρ S ), and thermal conductivity (k) of deparaffinized and formalin-fixed paired tumor and adjacent normal breast biopsy samples from N = 8 patients were measured. For formalin-fixed samples, the mean ρ B for tumors showed a statistically significant fold change of 4.42 (P = 0.014) when the tissue was heated from 25 °C to 37 °C compared to the adjacent normal tissue, which showed a fold change of 3.47. The mean ρ S measurements also showed a similar trend. The mean k of the formalin-fixed tumor tissues was 0.309 ± 0.02 W m-1 K-1 compared to a significantly higher k of 0.563 ± 0.028 W m-1 K-1 for the adjacent normal tissues. A similar trend was observed in ρ B, ρ S, and k for the deparaffinized tissue samples. An analysis of a combination of ρ B , ρ S , and k using Fisher's combined probability test and linear regression suggests the advantage of using all three parameters simultaneously for distinguishing tumors from adjacent normal tissues with higher statistical significance.
Collapse
|
4
|
Conductivity of diblock copolymer system filled with conducting nano‐particles: Effect of copolymer morphology. JOURNAL OF POLYMER SCIENCE 2021. [DOI: 10.1002/pol.20210729] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
5
|
Quantum Dots: An Emerging Tool for Point-of-Care Testing. MICROMACHINES 2020; 11:E1058. [PMID: 33260478 PMCID: PMC7761335 DOI: 10.3390/mi11121058] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 10/09/2020] [Accepted: 10/13/2020] [Indexed: 01/03/2023]
Abstract
Quantum dots (QDs) are semiconductor crystals in the nanodimension having unique optical and electronic properties that differ from bulk material due to quantum mechanics. The QDs have a narrow emission peak, size-dependent emission wavelength, and broad excitation range which can be utilized for diverse biomedical applications such as molecular imaging, biosensing, and diagnostic systems. This article reviews the current developments of biomedical applications of QDs with special reference to point-of-care testing.
Collapse
|
6
|
A Prominent Cell Manipulation Technique in BioMEMS: Dielectrophoresis. MICROMACHINES 2020; 11:E990. [PMID: 33153069 PMCID: PMC7693018 DOI: 10.3390/mi11110990] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/22/2020] [Accepted: 10/28/2020] [Indexed: 12/17/2022]
Abstract
BioMEMS, the biological and biomedical applications of micro-electro-mechanical systems (MEMS), has attracted considerable attention in recent years and has found widespread applications in disease detection, advanced diagnosis, therapy, drug delivery, implantable devices, and tissue engineering. One of the most essential and leading goals of the BioMEMS and biosensor technologies is to develop point-of-care (POC) testing systems to perform rapid prognostic or diagnostic tests at a patient site with high accuracy. Manipulation of particles in the analyte of interest is a vital task for POC and biosensor platforms. Dielectrophoresis (DEP), the induced movement of particles in a non-uniform electrical field due to polarization effects, is an accurate, fast, low-cost, and marker-free manipulation technique. It has been indicated as a promising method to characterize, isolate, transport, and trap various particles. The aim of this review is to provide fundamental theory and principles of DEP technique, to explain its importance for the BioMEMS and biosensor fields with detailed references to readers, and to identify and exemplify the application areas in biosensors and POC devices. Finally, the challenges faced in DEP-based systems and the future prospects are discussed.
Collapse
|
7
|
Temperature dependence of the conductivity of filled diblock copolymers. Phys Rev E 2020; 102:052504. [PMID: 33327154 DOI: 10.1103/physreve.102.052504] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 11/06/2020] [Indexed: 06/12/2023]
Abstract
We demonstrate that an insulating diblock copolymer system (DBC) filled with conductive fillers can be used as an electrically responsive soft composite that changes its conductivity in response to temperature-induced changes in its morphology. By combining the phase field model describing the morphology of the DBC system with the Monte Carlo simulations and the resistor network model describing electrical properties of the filler network, we calculate the conductivity of this composite. The calculated conductivity is found to essentially depend, in particular, on the temperature of the composite. Changing the temperature is shown to result in morphological changes in the DBC system causing the structural changes in the filler network. In particular, the order-disorder transition in the host DBC system is found to be accompanied by the conductor-insulator transition in the filler network. The effect of the difference between the affinities of the fillers for dissimilar copolymer blocks on the composite conductivity, as well as the effect of the repulsive and attractive interaction between fillers, is considered in detail.
Collapse
|
8
|
Conductivity of Insulating Diblock Copolymer System Filled with Conductive Particles Having Different Affinities for Dissimilar Copolymer Blocks. Polymers (Basel) 2020; 12:polym12081659. [PMID: 32722506 PMCID: PMC7466120 DOI: 10.3390/polym12081659] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 07/21/2020] [Accepted: 07/21/2020] [Indexed: 11/16/2022] Open
Abstract
We investigate the electrical response of the insulating diblock copolymer system (DBC) filled with conductive spherical fillers depending on the affinities of these fillers for copolymer blocks and the interaction between fillers. We demonstrate that the contrast (difference) between the affinities of the fillers for dissimilar copolymer blocks is a decisive factor that determines the distribution of these fillers in the DBC system. The distribution of filler particles, in turn, is found to be directly related to the electrical response of the DBC-particle composite. In particular, increasing the affinity contrast above a certain threshold value results in the insulator-conductor transition. This transition is found to be caused by the preferential localization of the fillers in the microphases of the DBC system having larger affinity for these fillers. The effect of the interaction between fillers is found to be secondary to the described effect of the affinity contrast that dominates in determining the distribution of fillers in the composite. This effect of the inter-particle interactions is shown to be significant only when the affinity contrast and filler volume fraction are sufficiently large.
Collapse
|
9
|
Abstract
Point-of-care medical diagnosis demands immediate feedback on tissue pathology. Confocal endomicroscopy can provide real-time in vivo images with histology-like features. The working channel in medical endoscopes are becoming smaller in dimension. Microsystems methods can produce tiny mechanical scanners. We demonstrate a flexible fiber instrument for in vivo imaging as an endoscope accessory. The optical path is folded on-axis to reduce length while allowing the beam to expand and achieve a numerical aperture of 0.41. A high-speed parametric resonance mirror produces large deflection angles > 13°, and is mounted on a 2 mm diameter chip designed with clamp structures for reduced space. A compact lens assembly provides diffraction-limited lateral and axial resolution of 1.5 and [Formula: see text], respectively. A working distance of [Formula: see text] and field-of-view of [Formula: see text] m are achieved. Miniature apparatus is fabricated to assemble and align the scanhead components. The optics and scanner are packaged in a distal tip with 2.4 mm diameter and 10 mm rigid length. These dimensions allow the endomicroscope to pass forward easily through the 2.8 mm diameter working channel in medical endoscopes commonly used in clinical practice. Fluorescence images are collected in vivo at 10 frames per second in the colon of genetically-engineered mice that spontaneously develop adenomas. A FITC-labeled peptide heterodimer is administered intravenously to provide specific contrast. Sub-cellular structures are visualized to distinguish pre-malignant from normal mucosa. These results demonstrate use of microsystems methods to produce an ultra-compact instrument with sufficiently small dimensions for broad use.
Collapse
|
10
|
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip. MICROMACHINES 2020; 11:E599. [PMID: 32570945 PMCID: PMC7345732 DOI: 10.3390/mi11060599] [Citation(s) in RCA: 87] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Revised: 06/09/2020] [Accepted: 06/16/2020] [Indexed: 12/21/2022]
Abstract
Following the advancements in microfluidics and lab-on-a-chip (LOC) technologies, a novel biomedical application for microfluidic based devices has emerged in recent years and microengineered cell culture platforms have been created. These micro-devices, known as organ-on-a-chip (OOC) platforms mimic the in vivo like microenvironment of living organs and offer more physiologically relevant in vitro models of human organs. Consequently, the concept of OOC has gained great attention from researchers in the field worldwide to offer powerful tools for biomedical researches including disease modeling, drug development, etc. This review highlights the background of biochip development. Herein, we focus on applications of LOC devices as a versatile tool for POC applications. We also review current progress in OOC platforms towards body-on-a-chip, and we provide concluding remarks and future perspectives for OOC platforms for POC applications.
Collapse
|
11
|
A Paper Based Milli-Cantilever Sensor for Detecting Hydrocarbon Gases via Smartphone Camera. Anal Chem 2020; 92:8480-8486. [DOI: 10.1021/acs.analchem.0c01240] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
12
|
Abstract
The precise transportation of small-volume liquids in microfluidic and nanofluidic systems remains a challenge for many applications, such as clinical fluidical analysis. Here, we present a reliable digital pump that utilizes acoustic streaming induced by localized fluid-substrate interactions. By locally generating streaming via a C-shaped interdigital transducer (IDT) within a triangle-edged microchannel, our acoustofluidic pump can generate a stable unidirectional flow (∼nanoliter per second flow rate) with a precise digital regulation (∼second response time), and it is capable of handling aqueous solutions (e.g., PBS buffer) as well as high viscosity liquids (e.g., human blood) with a nanoliter-scale volume. Along with our acoustofluidic pump's low cost, programmability, and capacity to control small-volumes at high precision, it could be widely used for point-of-care diagnostics, precise drug delivery, and fundamental biomedical research.
Collapse
|
13
|
Microdevice Development and Artificial Organs. Artif Organs 2018; 43:17-20. [PMID: 30260017 DOI: 10.1111/aor.13288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Microfluidic flow cytometry: The role of microfabrication methodologies, performance and functional specification. TECHNOLOGY 2018; 6:1-23. [PMID: 29682599 PMCID: PMC5907470 DOI: 10.1142/s2339547818300019] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Flow cytometry is an invaluable tool utilized in modern biomedical research and clinical applications requiring high throughput, high resolution particle analysis for cytometric characterization and/or sorting of cells and particles as well as for analyzing results from immunocytometric assays. In recent years, research has focused on developing microfluidic flow cytometers with the motivation of creating smaller, less expensive, simpler, and more autonomous alternatives to conventional flow cytometers. These devices could ideally be highly portable, easy to operate without extensive user training, and utilized for research purposes and/or point-of-care diagnostics especially in limited resource facilities or locations requiring on-site analyses. However, designing a device that fulfills the criteria of high throughput analysis, automation and portability, while not sacrificing performance is not a trivial matter. This review intends to present the current state of the field and provide considerations for further improvement by focusing on the key design components of microfluidic flow cytometers. The recent innovations in particle focusing and detection strategies are detailed and compared. This review outlines performance matrix parameters of flow cytometers that are interdependent with each other, suggesting trade offs in selection based on the requirements of the applications. The ongoing contribution of microfluidics demonstrates that it is a viable technology to advance the current state of flow cytometry and develop automated, easy to operate and cost-effective flow cytometers.
Collapse
|
15
|
An ultrasensitive micropillar-based quartz crystal microbalance device for real-time measurement of protein immobilization and protein-protein interaction. Biosens Bioelectron 2018; 99:325-331. [DOI: 10.1016/j.bios.2017.07.074] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 07/27/2017] [Accepted: 07/30/2017] [Indexed: 10/19/2022]
|
16
|
Implanted Cardiac Pacemaker Mathematical Modeling and Research based on the Volume Conduction. INTERNATIONAL JOURNAL OF COGNITIVE INFORMATICS AND NATURAL INTELLIGENCE 2017. [DOI: 10.4018/ijcini.2017070105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The research of the communication between implanted Cardiac Pacemaker and external devices is a focus. In this paper, a data communications model based Volume Conduction is creatively presented, in this way the human body conductive ability will been utilized to transmit current, which is more effective and decrease for harm of the human body than the other ways, such as: RF, Optical Transcutaneous, etc. As the frequency increases the KHz level, the effect of background biological noise is considered negligible, the channel is thus modeled as AWGN channel in these frequencies. From Shannon information theory, in two-dimensional modulation, the volume conduction channel capacity formula was derived, further derivation: with extremely low SNR using in the two-level modulation can be very effective use of channel capacity, with high SNR a multi-level modulation is used in order to make full use of the channel capacity. Matlab software is used to the channel simulation, the input and output signal waveforms and eye diagram comparison, the curves of the BER and SNR.
Collapse
|
17
|
Abstract
Ingestible sensing capsules are fast emerging as a critical technology that has the ability to greatly impact health, nutrition, and clinical areas. These ingestible devices are noninvasive and hence are very attractive for customers. With widespread access to smart phones connected to the Internet, the data produced by this technology can be readily seen and reviewed online, and accessed by both users and physicians. The outputs provide invaluable information to reveal the state of gut health and disorders as well as the impact of food, medical supplements, and environmental changes on the gastrointestinal tract. One unique feature of such ingestible sensors is that their passage through the gut lumen gives them access to each individual organ of the gastrointestinal tract. Therefore, ingestible sensors offer the ability to gather images and monitor luminal fluid and the contents of each gut segment including electrolytes, enzymes, metabolites, hormones, and the microbial communities. As such, an incredible wealth of knowledge regarding the functionality and state of health of individuals through key gut biomarkers can be obtained. This Review presents an overview of the gut structure and discusses current and emerging digestible technologies. The text is an effort to provide a comprehensive overview of ingestible sensing capsules, from both a body physiology point of view as well as a technological view, and to detail the potential information that they can generate.
Collapse
|
18
|
Abstract
In recent years, rapid advancements have been made in the biomedical applications of microtechnology and nanotechnology. While the focus of such technologies have been primarily on in vitro analytical and diagnostic tools, more recently in vivo therapeutic and sensing applications have gained attention. The long-term integration of cells with inorganic materials provides the basis for novel sensing platforms. The work presented here focuses on the ability to maintain cells long-term in nanoporous silicon-based microenvironments. This paper describes the creation of nanoporous, biocompatible, alumina membranes as a platform for incorporation into a cell-based device targeted for in situ recording of cellular electrical activity variations due to the changes associated with the surrounding microenvironments. Studies described herein focus on the interaction of nanoporous alumina substrates embedded in silicon patterned with cells of interest. The fidelity of such a system is demonstrated in terms of viability, proliferation, and functionality. The capability of such microfabricated nanoporous membranes, as in vitro for cell-based assays for sensing and drug delivery applications, is also demonstrated. It has potential in vivo application for therapeutic immunoisolation.
Collapse
|
19
|
An implantable compound-releasing capsule triggered on demand by ultrasound. Sci Rep 2016; 6:22803. [PMID: 26965207 PMCID: PMC4786798 DOI: 10.1038/srep22803] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2015] [Accepted: 02/19/2016] [Indexed: 12/27/2022] Open
Abstract
Implantable devices have a large potential to improve human health, but they are often made of biofouling materials that necessitate special coatings, rely on electrical connections for external communication, and require a continuous power source. This paper demonstrates an alternative platform, which we call iTAG (implantable thermally actuated gel), where an implanted capsule can be wirelessly controlled by ultrasound to trigger the release of compounds. We constructed a millimeter-sized capsule containing a co-polymer gel (NiPAAm-co-AAm) that contracts above body temperature (i.e. at 45 °C) to release compounds through an opening. This gel-containing capsule is biocompatible and free of toxic electronic or battery components. An ultrasound hardware, with a focused ultrasound (FUS) transducer and a co-axial A-mode imaging transducer, was used to image the capsule (to monitor in real time its position, temperature, and effectiveness of dose delivery), as well as to trigger a rapid local rise in temperature, contraction of gel, and release of compounds in vitro and in vivo. The combination of this gel-based capsule and compact ultrasound hardware can serve as a platform for triggering local release of compounds, including potentially in deep tissue, to achieve tailored personalized therapy.
Collapse
|
20
|
Biomedical microelectromechanical systems (BioMEMS): Revolution in drug delivery and analytical techniques. Saudi Pharm J 2016; 24:1-20. [PMID: 26903763 PMCID: PMC4719786 DOI: 10.1016/j.jsps.2013.12.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2013] [Accepted: 12/14/2013] [Indexed: 01/19/2023] Open
Abstract
Advancement in microelectromechanical system has facilitated the microfabrication of polymeric substrates and the development of the novel class of controlled drug delivery devices. These vehicles have specifically tailored three dimensional physical and chemical features which together, provide the capacity to target cell, stimulate unidirectional controlled release of therapeutics and augment permeation across the barriers. Apart from drug delivery devices microfabrication technology’s offer exciting prospects to generate biomimetic gastrointestinal tract models. BioMEMS are capable of analysing biochemical liquid sample like solution of metabolites, macromolecules, proteins, nucleic acid, cells and viruses. This review summarized multidisciplinary application of biomedical microelectromechanical systems in drug delivery and its potential in analytical procedures.
Collapse
|
21
|
A micro opto-mechanical displacement sensor based on micro-diffraction gratings: design and characterization. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2013:4714-7. [PMID: 24110787 DOI: 10.1109/embc.2013.6610600] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A micro opto-mechanical displacement sensor is here presented. It is constituted by a sensing element based on two overlapped micro-diffraction gratings (MDGs). They present a platinum layer (45 nm of thick) on a glass substrate, a period of 525 µm constituted by a width of 150 µm of platinum separated (71.4% duty cycle). The working principle is based on the modulation of light intensity induced by the relative displacement between the MDGs: when a laser light perpendicularly hits the MDGs, the intensity of the transmitted light is a periodic function of the relative displacement between the two MDGs. A fiber optic is used to transport the transmitted light to a photodetector in order to avoid concerns related to the alignment between the optical components. The sensor's output is the ratio between the light intensity measured by the photodetector during the displacement of the MDGs and largest light intensity values measured in the whole range of measurement, therefore, it is lower than 1. The proposed sensor allows to discriminate displacement lower than 10 µm, using a cost effective micro-fabrication process implemented by the technique of Lift-Off. It shows a good linear behaviour in two ranges covering about one half of the MDGs period. Within the linear ranges it shows high sensitivity (about 0.5%/µm) and good accuracy (lower than 4% in the whole range of calibration); furthermore, the results show that a design with a duty cycle of 50% overcomes the marked decrease of sensitivity in a range of measurement corresponding to a grating period.
Collapse
|
22
|
Design and fabrication of a flexible MEMS-based electromechanical sensor array for breast cancer diagnosis. JOURNAL OF MICROMECHANICS AND MICROENGINEERING : STRUCTURES, DEVICES, AND SYSTEMS 2015; 25:075025. [PMID: 26526747 PMCID: PMC4624460 DOI: 10.1088/0960-1317/25/7/075025] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The use of flexible micro-electro-mechanical systems (MEMS) based device provides a unique opportunity in bio-medical robotics such as characterization of normal and malignant tissues. This paper reports on design and development of a flexible MEMS-based sensor array integrating mechanical and electrical sensors on the same platform to enable the study of the change in electro-mechanical properties of the benign and cancerous breast tissues. In this work, we present the analysis for the electrical characterization of the tissue specimens and also demonstrate the feasibility of using the sensor for mechanical characterization of the tissue specimens. Eight strain gauges acting as mechanical sensors were fabricated using poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) conducting polymer on poly(dimethylsiloxane) (PDMS) as the substrate material. Eight electrical sensors were fabricated using SU-8 pillars on gold (Au) pads which were patterned on the strain gauges separated by a thin insulator (SiO2 1.0μm). These pillars were coated with gold to make it conducting. The electromechanical sensors are integrated on the same substrate. The sensor array covers 180μm × 180μm area and the size of the complete device is 20mm in diameter. The diameter of each breast tissue core used in the present study was 1mm and the thickness was 8μm. The region of interest was 200μm × 200μm. Microindentation technique was used to characterize the mechanical properties of the breast tissues. The sensor is integrated with conducting SU-8 pillars to study the electrical property of the tissue. Through electro-mechanical characterization studies using this MEMS-based sensor, we were able to measure the accuracy of the fabricated device and ascertain the difference between benign and cancer breast tissue specimens.
Collapse
|
23
|
Clinical applications of biomedical microdevices for controlled drug delivery. Mayo Clin Proc 2015; 90:93-108. [PMID: 25484235 DOI: 10.1016/j.mayocp.2014.10.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Revised: 09/11/2014] [Accepted: 10/02/2014] [Indexed: 01/20/2023]
Abstract
Miniaturization of devices to micrometer and nanometer scales, combined with the use of biocompatible and functional materials, has created new opportunities for the implementation of drug delivery systems. Advances in biomedical microdevices for controlled drug delivery platforms promise a new generation of capabilities for the treatment of acute conditions and chronic illnesses, which require high adherence to treatment, in which temporal control over the pharmacokinetic profiles is critical. In addition, clinical conditions that require a combination of drugs with specific pharmacodynamic profiles and local delivery will benefit from drug delivery microdevices. This review provides a summary of various clinical applications for state-of-the-art controlled drug delivery microdevices, including cancer, endocrine and ocular disorders, and acute conditions such as hemorrhagic shock. Regulatory considerations for clinical translation of drug delivery microdevices are also discussed. Drug delivery microdevices promise a remarkable gain in clinical outcomes and a substantial social impact. A review of articles covering the field of microdevices for drug delivery was performed between January 1, 1990, and January 1, 2014, using PubMed as a search engine.
Collapse
|
24
|
Microfabricated tactile sensors for biomedical applications: a review. BIOSENSORS 2014; 4:422-48. [PMID: 25587432 PMCID: PMC4287711 DOI: 10.3390/bios4040422] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Revised: 10/12/2014] [Accepted: 10/29/2014] [Indexed: 01/27/2023]
Abstract
During the last decades, tactile sensors based on different sensing principles have been developed due to the growing interest in robotics and, mainly, in medical applications. Several technological solutions have been employed to design tactile sensors; in particular, solutions based on microfabrication present several attractive features. Microfabrication technologies allow for developing miniaturized sensors with good performance in terms of metrological properties (e.g., accuracy, sensitivity, low power consumption, and frequency response). Small size and good metrological properties heighten the potential role of tactile sensors in medicine, making them especially attractive to be integrated in smart interfaces and microsurgical tools. This paper provides an overview of microfabricated tactile sensors, focusing on the mean principles of sensing, i.e., piezoresistive, piezoelectric and capacitive sensors. These sensors are employed for measuring contact properties, in particular force and pressure, in three main medical fields, i.e., prosthetics and artificial skin, minimal access surgery and smart interfaces for biomechanical analysis. The working principles and the metrological properties of the most promising tactile, microfabricated sensors are analyzed, together with their application in medicine. Finally, the new emerging technologies in these fields are briefly described.
Collapse
|
25
|
SU-8 as a material for lab-on-a-chip-based mass spectrometry. LAB ON A CHIP 2014; 14:3668-3689. [PMID: 25029537 DOI: 10.1039/c4lc00617h] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This short review focuses on the application of SU-8 for the microchip-based approach to the miniaturization of mass spectrometry. Chip-based mass spectrometry will make the technology commonplace and bring benefits such as lower costs and autonomy. The chip-based miniaturization of mass spectrometry necessitates the use of new materials which are compatible with top-down fabrication involving both planar and non-planar processes. In this context, SU-8 is a very versatile epoxy-based, negative tone resist which is sensitive to ultraviolet radiation, X-rays and electron beam exposure. It has a very wide thickness range, from nanometres to millimetres, enabling the formation of mechanically rigid, very high aspect ratio, vertical, narrow width structures required to form microfluidic slots and channels for laboratory-on-a-chip design. It is also relatively chemically resistant and biologically compatible in terms of the liquid solutions used for mass spectrometry. This review looks at the impact and potential of SU-8 on the different parts of chip-based mass spectrometry - pre-treatment, ionization processes, and ion sorting and detection.
Collapse
|
26
|
Abstract
There is no doubt that controlled and pulsatile drug delivery system is an important challenge in medicine over the conventional drug delivery system in case of therapeutic efficacy. However, the conventional drug delivery systems often offer a limited by their inability to drug delivery which consists of systemic toxicity, narrow therapeutic window, complex dosing schedule for long term treatment etc. Therefore, there has been a search for the drug delivery system that exhibit broad enhancing activity for more drugs with less complication. More recently, some elegant study has noted that, a new type of micro-electrochemical system or MEMS-based drug delivery systems called microchip has been improved to overcome the problems related to conventional drug delivery. Moreover, micro-fabrication technology has enabled to develop the implantable controlled released microchip devices with improved drug administration and patient compliance. In this article, we have presented an overview of the investigations on the feasibility and application of microchip as an advanced drug delivery system. Commercial manufacturing materials and methods, related other research works and current advancement of the microchips for controlled drug delivery have also been summarized.
Collapse
|
27
|
Development of vertical SU-8 microneedles for transdermal drug delivery by double drawing lithography technology. BIOMICROFLUIDICS 2013; 7:66501. [PMID: 24396551 PMCID: PMC3869848 DOI: 10.1063/1.4843475] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Accepted: 11/26/2013] [Indexed: 05/05/2023]
Abstract
Polymer-based microneedles have drawn much attention in transdermal drug delivery resulting from their flexibility and biocompatibility. Traditional fabrication approaches are usually time-consuming and expensive. In this study, we developed a new double drawing lithography technology to make biocompatible SU-8 microneedles for transdermal drug delivery applications. These microneedles are strong enough to stand force from both vertical direction and planar direction during penetration. They can be used to penetrate into the skin easily and deliver drugs to the tissues under it. By controlling the delivery speed lower than 2 μl/min per single microneedle, the delivery rate can be as high as 71%.
Collapse
|
28
|
Abstract
Wireless capsule endoscopy (WCE) can be considered an example of disruptive technology since it represents an appealing alternative to traditional diagnostic techniques. This technology enables inspection of the digestive system without discomfort or need for sedation, thus preventing the risks of conventional endoscopy, and has the potential of encouraging patients to undergo gastrointestinal (GI) tract examinations. However, currently available clinical products are passive devices whose locomotion is driven by natural peristalsis, with the drawback of failing to capture the images of important GI tract regions, since the doctor is unable to control the capsule's motion and orientation. To address these limitations, many research groups are working to develop active locomotion devices that allow capsule endoscopy to be performed in a totally controlled manner. This would enable the doctor to steer the capsule towards interesting pathological areas and to accomplish medical tasks. This review presents a research update on WCE and describes the state of the art of the basic modules of current swallowable devices, together with a perspective on WCE potential for screening, diagnostic, and therapeutic endoscopic procedures.
Collapse
|
29
|
Emerging technologies in medical applications of minimum volume vitrification. Nanomedicine (Lond) 2012; 6:1115-29. [PMID: 21955080 DOI: 10.2217/nnm.11.71] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Cell/tissue biopreservation has broad public health and socio-economic impact affecting millions of lives. Cryopreservation technologies provide an efficient way to preserve cells and tissues targeting the clinic for applications including reproductive medicine and organ transplantation. Among these technologies, vitrification has displayed significant improvement in post-thaw cell viability and function by eliminating harmful effects of ice crystal formation compared to the traditional slow freezing methods. However, high cryoprotectant agent concentrations are required, which induces toxicity and osmotic stress to cells and tissues. It has been shown that vitrification using small sample volumes (i.e., <1 µl) significantly increases cooling rates and hence reduces the required cryoprotectant agent levels. Recently, emerging nano- and micro-scale technologies have shown potential to manipulate picoliter to nanoliter sample sizes. Therefore, the synergistic integration of nanoscale technologies with cryogenics has the potential to improve biopreservation methods.
Collapse
|
30
|
|
31
|
Piezoelectricity and Ferroelectricity in Biomaterials: From Proteins to Self-assembled Peptide Nanotubes. NANOMEDICINE AND NANOTOXICOLOGY 2012. [DOI: 10.1007/978-3-642-28044-3_7] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
32
|
|
33
|
Models at the single cell level. WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE 2011; 2:34-48. [PMID: 20836009 DOI: 10.1002/wsbm.49] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Many cellular behaviors cannot be completely captured or appropriately described at the cell population level. Noise induced by stochastic chemical reactions, spatially polarized signaling networks, and heterogeneous cell-cell communication are among the many phenomena that require fine-grained analysis. Accordingly, the mathematical models used to describe such systems must be capable of single cell or subcellular resolution. Here, we review techniques for modeling single cells, including models of stochastic chemical kinetics, spatially heterogeneous intracellular signaling, and spatial stochastic systems. We also briefly discuss applications of each type of model.
Collapse
|
34
|
Cell adhesion properties on chemically micropatterned boron-doped diamond surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:15065-15069. [PMID: 20715878 DOI: 10.1021/la101757f] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The adhesion properties of living cells were investigated on a range of chemically modified boron-doped diamond (BDD) surfaces. We studied the influence of oxidized, H-, amine- (NH(2)-), methyl- (CH(3)-), trifluoromethyl- (CF(3)-) and vinyl- (CH(2)═CH-) terminated BDD surfaces on human osteosarcoma U2OS and mouse fibroblast L929 cells behavior. Cell-surface interactions were analyzed by fluorescence microscopy in terms of cell attachment, spreading and proliferation. U2OS cells poorly adhered on hydrophobic surfaces and their growth was blocked. In contrast, L929 cells were mainly influenced by the presence of perfluoroalkyl chains in regard to their morphology. The results were subsequently applied to selectively micropattern U2OS cells on dual hydrophobic/hydrophilic surfaces prepared by a UV/ozone lithographic approach. U2OS cells colonized preferentially hydrophilic (oxide-terminated) motifs, forming confluent arrays with distinguishable edges separating the alkyl regions.
Collapse
|
35
|
Abstract
This review focuses on the use of Förster Resonance Energy Transfer (FRET) to monitor intra- and intermolecular reactions occurring in microfluidic reactors. Microfluidic devices have recently been used for performing highly efficient and miniaturised biological assays for the analysis of biological entities such as cells, proteins and nucleic acids. Microfluidic assays are characterised by nanolitre to femtolitre reaction volumes, which necessitates the adoption of a sensitive optical detection scheme. FRET serves as a strong 'spectroscopic ruler' for elucidating the tertiary structure of biomolecules, as the efficiency of the non-radiative energy transfer is extremely sensitive to nanoscale changes in the separation between donor and acceptor markers attached to the biomolecule of interest. In this review, we will review the implementation of various microfluidic assays which employ FRET for diverse applications in the biomedical field, along with the advantages and disadvantages of the various approaches. The future prospects for development of microfluidic devices incorporating FRET detection will be discussed.
Collapse
|
36
|
Abstract
The utilization of microsystems technology (MST) in medical applications is instrumental in opening up new market segments, in the creation of novel, more effective diagnosis and therapy options in medicine, as well as in the further development of MST. However, the players in the healthcare industry are faced with technical and non-technical difficulties. The present study analyzes this emerging field from the viewpoint of medicine, market, and MST. It identifies applications of medical devices with microsystems components and analyzes their potentials in great detail. Thus, especially the creation of new market segments is expected from a broad use of MST in medicine. Furthermore, problems and conditions during the entry of microsystems into medical products are illuminated, in particular considering the specific market features of the healthcare industry. The high expenditure necessary for establishing this technology in healthcare industry is the most significant obstacle, since this market is dominated by small and medium-sized enterprises (SMEs). But there are non-technical difficulties as well. This article presents selected results of the study, which was carried out in the scope of the EU project netMED (virtual institute on micromechatronics for biomedical industry).
Collapse
|
37
|
Abstract
OBJECTIVE This review will describe the novel contributions to the field of nerve repair from the emerging disciplines of microtechnology and nanotechnology. METHOD This broad review will cover the advances described in the literature of the medical and biological fields and the engineering and physical sciences. The authors have also included their own work in this field. DISCUSSION Microtechnology and nanotechnology are providing two fundamentally different pathways for pursuing nerve repair: (1) microstructured scaffolds to promote regeneration and (2) direct repair by reconnecting axons. In the first instance, many of the traditional techniques for microfabrication of microelectronics have been applied to the development of implantable tissue scaffolds with precisely formed architectures. Combined with nanotechnological capabilities to control their surface chemistries, these tissue constructs have been designed to create a microenvironment within nerve tissue to optimally promote the outgrowth of neurites. With some initial successes in animal models, these next generation tissue scaffolds may provide a marked improvement over traditional nerve grafts in the ability to overcome nerve degenerative processes and to coax nerve regeneration leading to restoration of at least some nerve function. A second, completely different repair strategy aims to directly repair nerves at the microscale by acutely reconnecting severed or damaged axons immediately after injury and potentially forestalling the usual downstream degenerative processes. This strategy will take advantage of the traditional capabilities of microfabrication to create microelectromechanical systems that will serve as ultramicrosurgical tools that can operate at the micron scale and reliably manipulate individual axons without incurring damage. To bring about some restoration of a nerve's function, axon repair will have to be performed repetitively on a large scale and soon after injury. Development work is currently underway to bring about the feasibility of this technique. CONCLUSION With the emergence of microtechnology and nanotechnology, new methods for repairing nerves are being explored and developed. There have been two fundamental benefits from the technologies of the ultrasmall scale: (1) enhancement of regeneration using new tissue scaffold materials and architecture; (2) direct repair of nerves at the scale of single neurons and axons.
Collapse
|
38
|
|
39
|
Technology Advances and Challenges in Hermetic Packaging for Implantable Medical Devices. IMPLANTABLE NEURAL PROSTHESES 2 2009. [DOI: 10.1007/978-0-387-98120-8_2] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
40
|
The evolution of chemotaxis assays from static models to physiologically relevant platforms. Integr Biol (Camb) 2008; 1:170-81. [PMID: 20023801 DOI: 10.1039/b814567a] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The role of chemotactic gradients in the immunological response is an area which elicits a lot of attention due to its impact on the outcome of the inflammatory process. Consequently there are numerous standard in vitro designs which attempt to mimic chemotactic gradients, albeit in static conditions, and with no control over the concentration of the chemokine gradient. In recent times the design of the standard chemotaxis assay has incorporated modern microfluidic platforms, computer controlled flow devices and cell tracking software. Assays under fluid flow which use biochips have provided data which highlight the importance of shear stress on cell attachment and migration towards a chemokine gradient. However, the in vivo environment is far more complex in comparison to conventional cell assay chambers. The designs of biochips are therefore in constant flux as advances in technology permit ever greater imitations of in vivo conditions. Researchers are focused on designing a generation of new biochips and enhancing the physiological relevance of the current assays. The challenge is to combine a shear flow with a 3D scaffold containing the endothelial layer and permitting a natural diffusion of chemokines through a tissue-like basal matrix. Here we review the latest range of chemotaxis assays and assess the innovative features of their designs which enable them to better imitate the in vivo environment. We also present some alternative designs that were initially employed in tissue engineering which could potentially be used in the establishment of novel chemotaxis assays.
Collapse
|
41
|
Microfabricated implants for applications in therapeutic delivery, tissue engineering, and biosensing. LAB ON A CHIP 2008; 8:1864-78. [PMID: 18941687 PMCID: PMC2970504 DOI: 10.1039/b806446f] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
By adapting microfabrication techniques originally developed in the microelectronics industry novel devices for drug delivery, tissue engineering and biosensing have been engineered for in vivo use. Implant microfabrication uses a broad range of techniques including photolithography, and micromachining to create devices with features ranging from 0.1 to hundreds of microns with high aspect ratios and precise features. Microfabrication offers device feature scale that is relevant to the tissues and cells to which they are applied, as well as offering ease of en masse fabrication, small device size, and facile incorporation of integrated circuit technology. Utilizing these methods, drug delivery applications have been developed for in vivo use through many delivery routes including intravenous, oral, and transdermal. Additionally, novel microfabricated tissue engineering approaches propose therapies for the cardiovascular, orthopedic, and ocular systems, among others. Biosensing devices have been designed to detect a variety of analytes and conditions in vivo through both enzymatic-electrochemical reactions and sensor displacement through mechanical loading. Overall, the impact of microfabricated devices has had an impact over a broad range of therapies and tissues. This review addresses many of these devices and highlights their fabrication as well as discusses materials relevant to microfabrication techniques.
Collapse
|
42
|
Abstract
Stimuli-responsive polymer gels have received considerable attention due to their singular mechanical properties, which make them materials of choice for niche applications. Polymer gels comprising either physical or chemical cross-links can undergo controlled and reversible shape changes in response to an applied field. The stimulus or external field applied may include thermal, electrical, magnetic, pH, UV/visible light, ionic or metallic interactions or combinations thereof. The shape change can manifest itself in two-dimensional actuation, bending motion, or three-dimensional actuation, volume change. This reversible contraction and expansion of polymer gels as well as their mechanical properties are similar to that of biological muscles. This review will describe and critique some of the recent advances in the field of stimuli-responsive polymer gels including the design of new classes of polymeric gels, controlled actuation in response to external stimuli, and ability to tailor material properties for different applications.
Collapse
|
43
|
Patterning Fluid and Elastomeric Surfaces Using Short-Wavelength UV Radiation and Photogenerated Reactive Oxygen Species. Annu Rev Phys Chem 2008; 59:411-32. [DOI: 10.1146/annurev.physchem.58.032806.104644] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
44
|
Silicon oxide surface functionalization by self-assembled nanolayers for microcantilever transducers. Colloids Surf A Physicochem Eng Asp 2008. [DOI: 10.1016/j.colsurfa.2008.01.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
45
|
Stepwise self-assembly of a protein nanoarray from a nanoimprinted poly(ethylene glycol) hydrogel. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2008; 4:342-8. [PMID: 18256998 DOI: 10.1002/smll.200700865] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
|
46
|
Abstract
OBJECTIVE Microfabricated devices with nanoscale features have been proposed as new microinstrumentation for cellular and subcellular surgical procedures, but their effectiveness in vivo has yet to be demonstrated. In this study, we examined the in vivo use of 10 to 100 microm-long nanoknives with cutting edges of 20 nm in radius of curvature during peripheral nerve surgery. METHODS Peripheral nerves from anesthetized mice were isolated on a rudimentary microplatform with stimulation microelectrodes, and the nanoknives were positioned by a standard micromanipulator. The surgical field was viewed through a research microscope system with brightfield and fluorescence capabilities. RESULTS Using this assembly, the nanoknife effectively made small, 50 to 100 microm-long incisions in nerve tissue in vivo. This microfabricated device was also robust enough to make repeated incisions to progressively pare down the nerve as documented visually and by the accompanying incremental diminution of evoked motor responses recorded from target muscle. Furthermore, this nanoknife also enabled the surgeon to perform procedures at an unprecedented small scale such as the cutting and isolation of a small segment from a single constituent axon in a peripheral nerve in vivo. Lastly, the nanoknife material (silicon nitride) did not elicit any acute neurotoxicity as evidenced by the robust growth of axons and neurons on this material in vitro. CONCLUSION Together, these demonstrations support the concept that microdevices deployed in a neurosurgical environment in vivo can enable novel procedures at an unprecedented small scale. These devices are potentially the vanguard of a new family of microscale instrumentation that can extend surgical procedures down to the cellular scale and beyond.
Collapse
|
47
|
|
48
|
Abstract
A new functionalization procedure was developed to replace cyltrimethylammoniumbromide coating on gold nanorods (GNRs) fabricated through seed-mediated growth with chemically active alkanethiols; antibodies were then attached to the GNRs to yield gold nanorod molecular probes (GNrMPs). The functionalization procedure was shown to minimize nonspecific binding. Multiplex sensing was demonstrated for three targets (goat anti-human IgG, goat anti-rabbit IgG, and goat anti-mouse IgG) through the distinct response of the plasmon spectra of GNrMPs to binding events. Quantification of the plasmonic binding events and estimation of ligand binding kinetics tethered to these nanoscale structures was also demonstrated through a mathematical approach. Evaluation of the experimental and theoretical data yields an affinity constant K(a) = 1.34 x 10(7) M(-1), which was in agreement with the IgG-antiIgG binding affinity reported in the literature. The GNrMP sensors were found to be highly specific and sensitive with the dynamic response in the range between 10(-9) M and 10(-6) M. The limit of detection of GNrMPs was found to be in the low nanomolar range, and is a function of the binding affinity: for a higher probe-target affinity pair, the limit of detection can be expected to reach femto molar levels. This technique can play a key role in developing tunable sensors for sensitive and precise monitoring of biological interactions.
Collapse
|
49
|
Abstract
In the recent past, the introduction of miniaturised image sensors with low power consumption, based on complementary metal oxide semiconductor (CMOS) technology, has allowed the realisation of an ingestible wireless capsule for the visualisation of the small intestine mucosa. The device has received approval from Food and Drug Administration and has gained momentum since it has been more successful than traditional techniques in the diagnosis of small intestine disorders. In 2004 an esophagus specific capsule was launched, while a solution for colon is still under development. However, present solutions suffer from several limitations: they move passively by exploiting peristalsis, are not able to stop intentionally for a prolonged diagnosis, they receive power from an internal battery with short length, and their usage is restricted to one organ, either small bowel or esophagus. However the steady progresses in many branches of engineering, including microelectromechanical systems (MEMS), are envisaged to affect the performances of capsular endoscopy. The near future foreshadows capsules able to pass actively through the whole gastrointestinal tract, to retrieve views from all organs and to perform drug delivery and tissue sampling. In the long term, the advent of robotics could lead to autonomous medical platforms, equipped with the most advanced solutions in terms of MEMS for therapy and diagnosis of the digestive tract. In this review, we discuss the state of the art of wireless capsule endoscopy (WCE): after a description on the current status, we present the most promising solutions.
Collapse
|
50
|
Microfabricated silicon leak for sampling planetary atmospheres with a mass spectrometer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2007; 78:065109. [PMID: 17614640 DOI: 10.1063/1.2748360] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
A microfabricated silicon mass spectrometer inlet leak has been designed, fabricated, and tested. This leak achieves a much lower conductance in a smaller volume than is possible with commonly available metal or glass capillary tubing. It will also be shown that it is possible to integrate significant additional functionality, such as inlet heaters and valves, into a silicon microleak with very little additional mass. The fabricated leak is compatible with high temperature (up to 500 degrees C) and high pressure (up to 100 bars) conditions, as would be encountered on a Venus atmospheric probe. These leaks behave in reasonable agreement with their theoretically calculated conductance, although this differs between devices and from the predicted value by as much as a factor of 2. This variation is believed to be the result of nonuniformity in the silicon etching process which is characterized in this work. Future versions of this device can compensate for characterized process variations in order to produce devices in closer agreement with designed conductance values. The integration of an inlet heater into the leak device has also been demonstrated in this work.
Collapse
|