1
|
Radiation dose management system in computed tomography procedures: a systematic review. RADIATION PROTECTION DOSIMETRY 2023:7130979. [PMID: 37078550 DOI: 10.1093/rpd/ncad124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 05/03/2023]
Abstract
A systematic literature review was carried out to explore articles that reported the use of radiation dose management systems (RDMSs) in computed tomography (CT). The preferred reporting items for systematic review and meta-analysis flow chart were used to screen articles in PubMed, EBSCOhost, Web of Science, SCOPUS and Cochrane Library. A total of 1041 articles were retrieved and screened. After evaluation against criteria, 38 articles were selected and synthesised narratively. The results revealed that several RDMSs have been used in CT. The review also indicated that the use of RDMSs has promoted the implementation of diagnostic reference levels for dose optimisation. A RDMS, such as DoseWatch, is associated with compatibility challenges and failure in data transmission, while manual RDMSs are cumbersome and prone to data entry errors. Thus, a robust automated RDMS that is compatible with the different CT systems would provide efficient CT dose management.
Collapse
|
2
|
Computed Tomography Radiation Exposure among Urinary Tract Stone Patients at Tikur Anbessa Specialized Hospital: A Retrospective Study. Ethiop J Health Sci 2022; 32:33-40. [PMID: 36339957 PMCID: PMC9624098 DOI: 10.4314/ejhs.v32i1.6s] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 06/26/2022] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND National and multinational surveys indicate large variability of Computed Tomography urinary tract Stone doses. The wide use of abdominopelvic Computed Tomography in the diagnosis, raised the issue of radiation exposure. Hence, this study was conducted to assess Computed Tomography radiation exposure of urinary tract Stone Patients there by, to compare the results from established reference values and other published studies. METHODS A retrospective cross-sectional was done on 100 urinary tract Stone patients who have at least one computed tomography scan as part of their follow-up or for diagnosis purposes from February 1 to May 31, 2021, at Tikur Anbesa Specialized Hospital. Data were collected using a structured questionnaire format that evaluates the number of Computed Tomography they had, scan parameters, dose indicators, and socio-demographic characteristics. Finally, the collected data were analyzed using statistical software SPSS version 22. RESULTS Out of 100 patients 3.6%of our patients have radiation exposure of more than 4mSv, which is the standard for low-dose Computed Tomography. The median radiation exposure is 1.27mSv per scan. Exposure factors like tube current, tube current products, dose length product, and scan range all have similar values with an almost null interquartile range. All the scans that overpassed the low dose threshold(4mSv) were done outside Tikur Anbesa Specialized Hospital. CONCLUSION Our study showed that Tikur Anbesa Specialized Hospital's low-dose CT protocol for patients with urinary tract Stone is well optimized as opposed to non- Tikur Anbesa Specialized Hospital.
Collapse
|
3
|
Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels. BMC Med Imaging 2022; 22:112. [PMID: 35690743 PMCID: PMC9188687 DOI: 10.1186/s12880-022-00838-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 06/02/2022] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION Diagnostic Reference Levels (DRLs), typically set at the 75th percentile of the dose distribution from surveys conducted across a broad user base using a specified dose-measurement protocol, are recommended for radiological examinations. There is a need to develop and implement DRLs as a standardisation and optimisation tool for the radiological protection of patients at Computed Tomography (CT) facilities. METHODS This was a retrospective cross-sectional study conducted in seven (7) different CT scan facilities in which participants were recruited by systematic random sampling. The study variables were dose length product (DLP) and volume-weighted CTDI (CTDIvol) for the radiation doses for head, chest, abdomen and lumbar spine CT examinations. The DRLs for CTDIvol and DLP were obtained by calculating the 3rd quartiles of the radiation doses per study site by anatomical region. The national diagnostic reference levels were determined by computation of DRLs using the 75th centile of the median values. RESULTS A total of 574 patients were examined with an average age of 47.1 years. For CTDIvol estimates; there was a strong positive significant relationship between the CTDIvol and examination mAs (rs = 0.9017, p-value < 0.001), and reference mAs (rs = 0.0.7708, p-value < 0.001). For DLP estimates; there was a moderate positive significant relationships between DLP and total mAs (rs = 0.6812, p-value < 0.001), reference mAs (rs = 0.5493, p-value < 0.001). The DRLs were as follows; for head CT scan - the average median CTDIvol was 56.02 mGy and the DLP was 1260.3 mGy.cm; for Chest CT, the CTDI volume was 7.82 mGy and the DLP was 377.0 mGy.cm; for the abdomen CT, the CTDI volume 12.54 mGy and DLP 1418.3 mGy.cm and for the lumbar spine 19.48 mGy and the DLP was 843 mGy.cm, respectively. CONCLUSION This study confirmed the need to optimize the CT scan parameters in order to lower the national DRLs. This can be achieved by extensive training of all the CT scan radiographers on optimizing the CT scan acquisition parameters. Continuous dose audits are also advised with new equipment or after every three years to ensure that values out of range are either justified or further investigated.
Collapse
|
4
|
CT Angiography for the Detection of Pulmonary Embolism: Role of Tube Voltage and Contrast Injection Rate on Diagnostic Confidence. Acad Radiol 2022; 29 Suppl 2:S91-S97. [PMID: 33602596 DOI: 10.1016/j.acra.2021.01.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 12/30/2020] [Accepted: 01/13/2021] [Indexed: 11/01/2022]
Abstract
RATIONALE AND OBJECTIVES Pulmonary CTA is the current standard method to assess for suspected pulmonary embolism. In some instances, the test results in low confidence interpretations. Our purpose was to compare the diagnostic confidence for three different scan protocols. MATERIALS AND METHODS Pulmonary CTA images from 401 patients were retrospectively analyzed. 202 studies used a tube voltage of 120 kVp and a contrast injection rate of 4 cc/s, 99 studies 120 kVp and 5 cc/s, and 100 studies 100 kVp and 4 cc/s. The level of diagnostic confidence was extracted from the final clinical reports. For each study, attenuation of the pulmonary artery, image noise, signal-to-noise ratio (SNR), and radiation dose were compared. RESULTS The 120 kVp, 5 cc/s protocol resulted in high diagnostic confidence in 84% of cases, more than with the 120 kVp, 4cc/s (65%) and the 100 kVp protocol (65%, p < 0.004). The 100 kVp protocol had a lower radiation dose, higher image noise, lower SNR, but equal and higher attenuation values of the pulmonary artery. CONCLUSION The reduction of tube voltage to 100 kVp at 4 cc/s maintains diagnostic confidence with lower radiation exposure, but does not equal the higher confidence achieved with 120 kVp at 5cc/s.
Collapse
|
5
|
CT Noise-Reduction Methods for Lower-Dose Scanning: Strengths and Weaknesses of Iterative Reconstruction Algorithms and New Techniques. Radiographics 2021; 41:1493-1508. [PMID: 34469209 DOI: 10.1148/rg.2021200196] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Iterative reconstruction (IR) algorithms are the most widely used CT noise-reduction method to improve image quality and have greatly facilitated radiation dose reduction within the radiology community. Various IR methods have different strengths and limitations. Because IR algorithms are typically nonlinear, they can modify spatial resolution and image noise texture in different regions of the CT image; hence traditional image-quality metrics are not appropriate to assess the ability of IR to preserve diagnostic accuracy, especially for low-contrast diagnostic tasks. In this review, the authors highlight emerging IR algorithms and CT noise-reduction techniques and summarize how these techniques can be evaluated to help determine the appropriate radiation dose levels for different diagnostic tasks in CT. In addition to advanced IR techniques, we describe novel CT noise-reduction methods based on convolutional neural networks (CNNs). CNN-based noise-reduction techniques may offer the ability to reduce image noise while maintaining high levels of image detail but may have unique drawbacks. Other novel CT noise-reduction methods are being developed to leverage spatial and/or spectral redundancy in multiphase or multienergy CT. Radiologists and medical physicists should be familiar with these different alternatives to adapt available CT technology for different diagnostic tasks. The scope of this article is (a) to review the clinical applications of IR algorithms as well as their strengths, weaknesses, and methods of assessment and (b) to explore new CT image reconstruction and noise-reduction techniques that promise to facilitate radiation dose reduction. ©RSNA, 2021.
Collapse
|
6
|
Use of Three-Dimensional Printing in Modelling an Anatomical Structure with a High Computed Tomography Attenuation Value: A Feasibility Study. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS 2021. [DOI: 10.1166/jmihi.2021.3664] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Introduction: Three-dimensional (3D) printing provides an opportunity to develop anthropomorphic computed tomography (CT) phantoms with anatomical and radiological features mimicking a range of patients’ conditions, thus allowing development of individualised, low dose
scanning protocols. However, previous studies of 3D printing in CT phantom development could only create anatomical structures using potassium iodide with attenuation values up to 1200 HU which is insufficient to mimic the radiological features of some high attenuation structures such as cortical
bone. This study aimed at investigating the feasibility of using 3D printing in modelling cortical bone with a non-iodinated material. Methods: This study had 2 stages. Stage 1 involved a vat photopolymerisation 3D printer to directly print cube phantoms with different percentage compositions
of calcium phosphate (CP) and resin (approach 1), and approach 2 using a material extrusion 3D printer to develop a cube mould for infilling of the CP with hardener as the phantom. The approach able to create the cube phantom with the CT attenuation value close to that of a tibial mid-diaphysis
cortex of a real patient, 1475±205 HU was employed to develop a tibial mid-diaphysis phantom. The mean CT numbers of the cube and tibia phantoms were measured and compared with that of the original CT dataset through unpaired t-test. Results: All phantoms were scanned by CT using
a lower extremity scanning protocol. The moulding approach was selected to develop the tibia middiaphysis phantom with CT attenuation value, 1434±184 HU which was not statistically significantly different from the one of the original dataset (p = 0.721). Conclusion: This
study demonstrates the feasibility to use the material extrusion 3D printer to create a tibial mid-diaphysis mould for infilling of the CP as an anthropomorphic CT phantom and the attenuation value of its cortex matches the real patient’s one.
Collapse
|
7
|
One size does not fit all: Factors associated with increased frequency of radiation overexposure alerts based on fixed-alert thresholds. Phys Med 2021; 82:79-86. [PMID: 33601164 DOI: 10.1016/j.ejmp.2021.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 01/22/2021] [Accepted: 02/06/2021] [Indexed: 10/22/2022] Open
Abstract
OBJECTIVES Quantify the expected rate of CT radiation dose alerts for three body regions using accepted radiation dose benchmarks and assess key determinants of alert frequency. METHODS This IRB-approved retrospective cohort study evaluated consecutive CT examinations performed between July and December 2013 within an academic medical system. CTDIvol x-ray tube output metrics were compared to the body-region-specific benchmark levels, Achievable Doses (AD), Diagnostic Reference Levels (DRL), and Dose Notification Values (DNV). A logistic regression model for the simulated alerts was fit as a function of the independent predictors: scanner, body region, gender, weight, and age. RESULTS For 17,000 exams, the proportion of events triggering alerts increased with patient weight. Significant covariates were scanner, body region, patient weight and patient age (all p < 0.0001). Odds of alert generation for the AD, DRL, and DNV benchmarks increased by 7.6%, 6.6% and 2.9% per kilogram, respectively, and by 0.8%, 1.1% and -2.7% per year of age (all p < 0.0001). Compared to the most highly optimized scanner, odds of alert generation varied by a factor of 595 for AD, 1126 for DRL, and 13 for DNV. CONCLUSION Alert frequency was significantly correlated with weight, age, body region and scanner. Controllable factors include scanner functionality and associated protocol optimization. Patient factors driving alert frequency are predominantly weight, and to a lesser degree, age. Size-agnostic fixed dose thresholds can frequently produce false positive alerts in appropriately performed exams of large patients, while missing opportunities to identify outlier scans of higher-than-expected dose in small patients.
Collapse
|
8
|
Task-based assessment of neck CT protocols using patient-mimicking phantoms-effects of protocol parameters on dose and diagnostic performance. Eur Radiol 2020; 31:3177-3186. [PMID: 33151393 PMCID: PMC8043932 DOI: 10.1007/s00330-020-07374-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 08/18/2020] [Accepted: 10/05/2020] [Indexed: 11/25/2022]
Abstract
Objectives To assess how modifying multiple protocol parameters affects the dose and diagnostic performance of a neck CT protocol using patient-mimicking phantoms and task-based methods. Methods Six patient-mimicking neck phantoms containing hypodense lesions of 1 cm diameter and 30 HU contrast and one non-lesion phantom were examined with 36 CT protocols. All possible combinations of the following parameters were investigated: 100- and 120-kVp tube voltage; tube current modulation (TCM) noise levels of SD 7.5, 10, and 14; pitches of 0.637, 0.813, and 1.388; filtered back projection (FBP); and iterative reconstruction (AIDR 3D). Dose-length products (DLPs) and lesion detectability (assessed by 14 radiologists) were compared with the clinical standard protocol (120 kVp, TCM SD 7.5, 0.813 pitch, AIDR 3D). Results The DLP of the standard protocol was 25 mGy•cm; the area under the curve (AUC) was 0.839 (95%CI: 0.790–0.888). Combined effects of tube voltage reduction to 100 kVp and TCM noise level increase to SD 10 optimized protocol performance by improving dose (7.3 mGy•cm) and detectability (AUC 0.884, 95%CI: 0.844–0.924). Diagnostic performance was significantly affected by the TCM noise level at 120 kVp (AUC 0.821 at TCM SD 7.5 vs. 0.776 at TCM SD 14, p = 0.003), but not at 100-kVp tube voltage (AUC 0.839 at TCM SD 7.5 vs. 0.819 at TCM SD 14, p = 0.354), the reconstruction method at 100 kVp (AUC 0.854 for AIDR 3D vs. 0.806 for FBP, p < 0.001), but not at 120-kVp tube voltage (AUC 0.795 for AIDR 3D vs. 0.793 for FBP, p = 0.822), and the tube voltage for AIDR 3D reconstruction (p < 0.001), but not for FBP (p = 0.226). Conclusions Combined effects of 100-kVp tube voltage, TCM noise level of SD 10, a pitch of 0.813, and AIDR 3D resulted in an optimal neck protocol in terms of dose and diagnostic performance. Protocol parameters were subject to complex interactions, which created opportunities for protocol improvement. Key Points • A task-based approach using patient-mimicking phantoms was employed to optimize a CT system for neck imaging through systematic testing of protocol parameters. • Combined effects of 100-kVp tube voltage, TCM noise level of SD 10, a pitch of 0.813, and AIDR 3D reconstruction resulted in an optimal protocol in terms of dose and diagnostic performance. • Interactions of protocol parameters affect diagnostic performance and should be considered when optimizing CT techniques. Electronic supplementary material The online version of this article (10.1007/s00330-020-07374-8) contains supplementary material, which is available to authorized users.
Collapse
|
9
|
Volumetric Differences in the Suprafascial and Subfascial Compartments of Patients with Secondary Unilateral Lower Limb Lymphedema. Plast Reconstr Surg 2020; 145:1528-1537. [PMID: 32459781 DOI: 10.1097/prs.0000000000006844] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
BACKGROUND The subfascial compartment (deep to the deep fascia) in extremity lymphedema has not been evaluated. This study investigated the volumetric differences between the suprafascial and subfascial compartments of patients with unilateral lower extremity lymphedema. METHODS Thirty-two female patients with unilateral lower extremity lymphedema were enrolled, with eight patients in each of Cheng lymphedema grades I to IV. The volumes of the suprafascial and subfascial compartments were calculated after manually drawing the region of interest on computed tomographic images. The volumetric differences and their ratios in the suprafascial and subfascial compartments between each patient's bilateral limbs were compared. RESULTS The volume of the lymphedematous limbs (9647 ml) was significantly greater than the volume of unaffected limbs (6906 ml), with a median volumetric difference of 2097 ml (30.6 percent) (p < 0.01). The median suprafascial compartment volumetric difference was 1887 ml (56.6 percent) and the subfascial compartment volumetric difference was 208 ml (4.7 percent) (p < 0.01). The median volumetric difference ratio of the thigh and lower leg was 24.6 percent and 40.6 percent, respectively. The median volumetric differences in Cheng lymphedema grades I to IV were 1012, 1787, 2434, and 4107 ml, respectively, which were statistically significant among the four Cheng lymphedema grades using the Kruskal-Wallis test (p < 0.01). CONCLUSIONS The volumetric differences in the lymphedematous limb were statistically significantly greater than in the unaffected limb, including both suprafascial and subfascial compartments. The volumetric differences are consistent with the Cheng lymphedema grading system as a reliable indicator of unilateral extremity lymphedema. CLINICAL QUESTION/LEVEL OF EVIDENCE Diagnostic, IV.
Collapse
|
10
|
Application of multiple injections of contrast agent in head and neck CT arteriovenous angiography in children: Study protocol clinical trial (SPIRIT Compliant). Medicine (Baltimore) 2020; 99:e19773. [PMID: 32282739 PMCID: PMC7220194 DOI: 10.1097/md.0000000000019773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE To investigate the application value of multiple injections of contrast agent in head and neck CT arteriovenous angiography in children. METHODS A total of 100 children aged 6 to 7 years who needed head and neck CT arteriovenous angiography were prospectively selected. They were randomly divided into a control group and a research group, with 50 children in each group. The same scanning parameters and reconstruction methods were used. The right median cubital vein was injected intravenously with the contrast agent Omnipaque (350 mg I/ml). For children in the control group, a bolus of undiluted contrast agent (dose was 2 ml/kg, upper limit was 50 ml) was injected 1 time. The arterial phase and vein phase of the head and neck vessels were scanned. For children in the research group, a contrast agent bolus diluted with saline to a concentration of 20% was first injected (dose was 1 ml/kg, upper limit was 25 ml), and then an undiluted contrast agent bolus (dose was 1 ml/kg, upper limit was 25 ml) was injected. Thresholds were used to trigger the scanning of the head and neck arterial phases. The CT image quality of the head and neck arteries and veins, radiation dose and contrast agent dose were compared between the 2 groups. RESULTS Subjective evaluation of CT image quality of arteries: there were 47 cases of 4 points and 3 cases of 3 points in the control group and 34 cases of 4 points and 16 cases of 3 points in the research group. Subjective evaluation of CT image quality of veins: there were 47 cases of 4 points and 3 cases of 3 points in the control group and 5 cases of 4 points, 42 cases of 3 points and 3 cases of 2 points in the research group. The CT value of brain arterial vessel enhancement was higher in the control group than the research group, and the difference was statistically significant (P < .05). The CT value of vein enhancement was higher in the control group than the research group, and the difference was statistically significant (P < .05). The X-ray dose in the research group was 51% lower than that in the control group; the contrast agent dose in the research group was 44% lower than that in the control group. CONCLUSION For the head and neck enhanced CT examination of children, the method of first bolus injection of 20% diluted contrast agent and later bolus injection of undiluted contrast agent can clearly demonstrate the head and neck arteries and veins one time, reducing the X-ray dose and contrast agent dose, which has clinical practical value in the enhanced CT examination of children with head and neck disease.
Collapse
|
11
|
Accuracy of Nonenhanced CT vs Contrast-Enhanced CT for Diagnosis of Acute Appendicitis in Adults. Curr Probl Diagn Radiol 2020; 50:315-320. [PMID: 32037023 DOI: 10.1067/j.cpradiol.2020.01.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 12/09/2019] [Accepted: 01/06/2020] [Indexed: 12/29/2022]
Abstract
BACKGROUND Acute appendicitis is one of the most common causes of acute abdominal pain requiring emergency intervention. It is often difficult for the clinician to make an accurate diagnosis due to nonspecific and overlapping clinical symptoms. Computed tomography (CT) has become the imaging modality of choice for the evaluation of suspected acute appendicitis. The main purpose of our study was to compare nonenhanced CT (NECT) with contrast-enhanced CT (CECT) for the diagnosis of acute appendicitis. MATERIAL AND METHODS A total of 140 patients were enrolled in the study. Two abdominal radiologists-masked to both the clinical information and the final diagnosis-retrospectively reviewed the computed tomographic findings and made an imaging diagnosis based on (1) NECT only, (2) CECT only, and (3) both NECT and CECT. With the final diagnosis as the reference standard, the accuracy of each CT technique was estimated. RESULTS The respective sensitivity, specificity, and accuracy for NECT, CECT, and NECT + CECT for the diagnosis of acute appendicitis were 80.7%, 86.7%, and 84.3%; 86.0%, 81.9%, and 83.6%; and, 87.7%, 80.7%, and 83.6%. There was no significant difference in the diagnosis of acute appendicitis among the 3 techniques. In order to make a correct diagnosis, the presence of at least 3 imaging findings for NECT or at least 4 for CECT had the best diagnostic accuracy. We also found that 9.25 mm was the optimal cut-off threshold for the detection of patients with acute appendicitis. CONCLUSION Our study allowed direct comparison between NECT, CECT, and NECT + CECT combined. There was no difference in the ability of each CT technique for diagnosing patients with acute appendicitis. For a patient whom iodinated contrast media is contraindicated or a patient who has an increased risk of severe adverse reaction, we would encourage the use of NECT because it provides comparable diagnostic accuracy without further exposing such patient to the contrast media.
Collapse
|
12
|
Prior iterative reconstruction (PIR) to lower radiation dose and preserve radiologist performance for multiphase liver CT: a multi-reader pilot study. Abdom Radiol (NY) 2020; 45:45-54. [PMID: 31705250 DOI: 10.1007/s00261-019-02280-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
PURPOSE Prior iterative reconstruction (PIR) spatially registers CT image data from multiple phases of enhancement to reduce image noise. We evaluated PIR in contrast-enhanced multiphase liver CT. METHODS Patients with archived projection CT data with proven malignant or benign liver lesions, or without lesions, by reference criteria were included. Lower-dose PIR images were reconstructed using validated noise insertion from multiphase CT exams (50% dose in 2 phases, 25% dose in 1 phase). The phase of enhancement most relevant to the diagnostic task was selected for evaluation. Four radiologists reviewed routine-dose and lower-dose PIR images, circumscribing liver lesions and rating confidence for malignancy (0 to 100) and image quality. JAFROC Figures of Merit (FOM) were calculated. RESULTS 31 patients had 60 liver lesions (28 primary hepatic malignancies, 6 hepatic metastases, 26 benign lesions). Pooled JAFROC FOM for malignancy for routine-dose CT was 0.615 (95% CI 0.464, 0.767) compared to 0.662 for PIR (95% CI 0.527, 0.797). The estimated FOM difference between the routine-dose and lower-dose PIR images was + 0.047 (95% CI - 0.023, + 0.116). Pooled sensitivity/specificity for routine-dose images was 70%/68% compared to 73%/66% for lower-dose PIR. Lower-dose PIR had lower diagnostic image quality (mean 3.8 vs. 4.2, p = 0.0009) and sharpness (mean 2.3 vs. 2.0, p = 0.0071). CONCLUSIONS PIR is a promising method to reduce radiation dose for multiphase abdominal CT, preserving observer performance despite small reductions in image quality. Further work is warranted.
Collapse
|
13
|
Ventilation/Perfusion SPECT Imaging Diagnosing PE and Other Cardiopulmonary Diseases. Clin Nucl Med 2020. [DOI: 10.1007/978-3-030-39457-8_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Patients undergoing recurrent CT exams: assessment of patients with non-malignant diseases, reasons for imaging and imaging appropriateness. Eur Radiol 2019; 30:1839-1846. [PMID: 31792584 DOI: 10.1007/s00330-019-06551-8] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/15/2019] [Accepted: 10/25/2019] [Indexed: 01/03/2023]
Abstract
OBJECTIVE To determine percent of patients without malignancy and ≤ 40 years of age with high cumulative radiation doses through recurrent CT exams and assess imaging appropriateness. METHODS From the cohort of patients who received cumulative effective dose (CED) of ≥ 100 mSv over a 5-year period, a sub-set was identified with non-malignant disease. The top 50 clinical indications leading to multiple CTs were determined. Clinical decision support (CDS) system scores were analyzed using a widely adopted standard of 1-3 (red) as "not usually appropriate," 4-6 (yellow) "may or may not be appropriate," and 7-9 (green) "usually appropriate." Clinicians reviewed patient records to assess compliance with appropriate use criteria (AUC). RESULTS 9.6% of patients in our series were with non-malignant conditions and 1.4% with age ≤ 40 years. CDS scores (rounded) were 2% red, 38% yellow, 27% green, and 33% unscored CTs. Clinical society guidelines for CT exams, wherever available, were followed in 87.5 to 100% of cases. AUCs were not available for several clinical indications as also referral guidelines for serial CT imaging. More than half of CT exams were unrelated to follow-up of a primary chronic disease. CONCLUSIONS We are faced with a situation wherein patients in age ≤ 40 years require or are thought to require many CT exams over the course of a few years but the radiation risk creates concern. There is a fair number of conditions for which AUC are not available. Suggested solutions include development of CT scanners with lesser radiation dose and further development of appropriateness criteria. KEY POINTS We are faced with a situation wherein patients in age group 0-40 years and with non-malignant diagnosis require or are thought to require many CT exams over the course of a few years. More than half of CT exams were unrelated to follow-up of a primary chronic disease. Imaging guidelines and appropriateness use criteria are not available for many conditions. Wherever available, they are for initial work-up and diagnosis and there is a lack of guidance on serial CT imaging.
Collapse
|
15
|
Abstract
IMPORTANCE The American College of Radiology (ACR) has recognized the importance of minimizing radiation doses used for lung cancer screening (LCS) computed tomography (CT). However, without standard protocols, doses could still be unnecessarily high, reducing screening margin of benefit. OBJECTIVE To characterize LCS CT radiation doses and identify factors explaining variation. DESIGN, SETTING, AND PARTICIPANTS We prospectively collected LCS examination dose metrics, from 2016 to 2017, at US institutions in the University of California, San Francisco International Dose Registry. Institution-level factors were collected through baseline survey. Mixed-effects linear and logistic regression models were estimated using forward variable selection. Results are presented as percentage excess dose and odds ratios (ORs) with 95% confidence intervals (CIs). The analysis was conducted between 2018 and 2019. MAIN OUTCOMES AND MEASURES Log-transformed measures of (1) mean volume CT dose index (CTDIvol, mGy), reflecting the average radiation dose per slice; (2) mean effective dose (ED, mSv), reflecting the total dose received and estimated future cancer risk; (3) proportion of CT scans using radiation doses above ACR benchmarks (CTDIvol >3 mGy, ED >1 mSv); and (4) proportion of CT scans using radiation doses above 75th percentile of registry doses (CTDIvol >2.7 mGy, ED >1.4 mSv). RESULTS Data were collected for 12 529 patients undergoing LCS CT scans performed at 72 institutions. Overall, 7232 participants (58%) were men, and the median age was 65 years (interquartile range [IQR], 60-70). Of 72 institutions, 15 (21%) had median CTDIvol and 47 (65%) had median ED above ACR guidelines. Institutions allowing any radiologists to establish protocols had 44% higher mean CTDIvol (mean dose difference [MDD], 44%; 95% CI, 19%-69%) and 27% higher mean ED (MDD, 27%; 95% CI, 5%-50%) vs those limiting who established protocols. Institutions allowing any radiologist to establish protocols had higher odds of examinations exceeding ACR CTDIvol guidelines (OR, 12.0; 95% CI, 2.0-71.4), and 75th percentile of registry CTDIvol (OR, 19.0; 95% CI, 1.9-186.7) or ED (OR, 8.5; 95% CI, 1.7-42.9). Having lead radiologists establish protocols resulted in lower odds of doses exceeding ACR ED guidelines (OR, 0.01; 95% CI, 0.001-0.1). Employing external vs internal medical physicists was associated with increased odds of exceeding ACR CTDIvol guidelines (OR, 6.1; 95% CI, 1.8-20.8). Having medical physicists establish protocols was associated with decreased odds of exceeding 75th percentile of registry CTDIvol (OR, 0.09; 95% CI, 0.01-0.59). Institutions reporting protocol updates as needed had 27% higher mean CTDIvol (MDD, 27%; 95% CI, 8%-45%). CONCLUSIONS AND RELEVANCE Facilities varied in LCS CT radiation dose distributions. Institutions limiting protocol creation to lead radiologists and having internal medical physicists had lower doses.
Collapse
|
16
|
EANM guideline for ventilation/perfusion single-photon emission computed tomography (SPECT) for diagnosis of pulmonary embolism and beyond. Eur J Nucl Med Mol Imaging 2019; 46:2429-2451. [PMID: 31410539 PMCID: PMC6813289 DOI: 10.1007/s00259-019-04450-0] [Citation(s) in RCA: 110] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 07/17/2019] [Indexed: 12/18/2022]
Abstract
These guidelines update the previous EANM 2009 guidelines on the diagnosis of pulmonary embolism (PE). Relevant new aspects are related to (a) quantification of PE and other ventilation/perfusion defects; (b) follow-up of patients with PE; (c) chronic PE; and (d) description of additional pulmonary physiological changes leading to diagnoses of left ventricular heart failure (HF), chronic obstructive pulmonary disease (COPD) and pneumonia. The diagnosis of PE should be reported when a mismatch of one segment or two subsegments is found. For ventilation, Technegas or krypton gas is preferred over diethylene triamine pentaacetic acid (DTPA) in patients with COPD. Tomographic imaging with V/PSPECT has higher sensitivity and specificity for PE compared with planar imaging. Absence of contraindications makes V/PSPECT an essential method for the diagnosis of PE. When V/PSPECT is combined with a low-dose CT, the specificity of the test can be further improved, especially in patients with other lung diseases. Pitfalls in V/PSPECT interpretation are discussed. In conclusion, V/PSPECT is strongly recommended as it accurately establishes the diagnosis of PE even in the presence of diseases like COPD, HF and pneumonia and has no contraindications.
Collapse
|
17
|
Evaluation of Lower-Dose Spiral Head CT for Detection of Intracranial Findings Causing Neurologic Deficits. AJNR Am J Neuroradiol 2019; 40:1855-1863. [PMID: 31649155 DOI: 10.3174/ajnr.a6251] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Accepted: 08/21/2019] [Indexed: 01/13/2023]
Abstract
BACKGROUND AND PURPOSE Despite the frequent use of unenhanced head CT for the detection of acute neurologic deficit, the radiation dose for this exam varies widely. Our aim was to evaluate the performance of lower-dose head CT for detection of intracranial findings resulting in acute neurologic deficit. MATERIALS AND METHODS Projection data from 83 patients undergoing unenhanced spiral head CT for suspected neurologic deficits were collected. Cases positive for infarction, intra-axial hemorrhage, mass, or extra-axial hemorrhage required confirmation by histopathology, surgery, progression of findings, or corresponding neurologic deficit; cases negative for these target diagnoses required negative assessments by two neuroradiologists and a clinical neurologist. A routine dose head CT was obtained using 250 effective mAs and iterative reconstruction. Lower-dose configurations were reconstructed (25-effective mAs iterative reconstruction, 50-effective mAs filtered back-projection and iterative reconstruction, 100-effective mAs filtered back-projection and iterative reconstruction, 200-effective mAs filtered back-projection). Three neuroradiologists circled findings, indicating diagnosis, confidence (0-100), and image quality. The difference between the jackknife alternative free-response receiver operating characteristic figure of merit at routine and lower-dose configurations was estimated. A lower 95% CI estimate of the difference greater than -0.10 indicated noninferiority. RESULTS Forty-two of 83 patients had 70 intracranial findings (29 infarcts, 25 masses, 10 extra- and 6 intra-axial hemorrhages) at routine head CT (CT dose index = 38.3 mGy). The routine-dose jackknife alternative free-response receiver operating characteristic figure of merit was 0.87 (95% CI, 0.81-0.93). Noninferiority was shown for 100-effective mAs iterative reconstruction (figure of merit difference, -0.04; 95% CI, -0.08 to 0.004) and 200-effective mAs filtered back-projection (-0.02; 95% CI, -0.06 to 0.02) but not for 100-effective mAs filtered back-projection (-0.06; 95% CI, -0.10 to -0.02) or lower-dose levels. Image quality was better at higher-dose levels and with iterative reconstruction (P < .05). CONCLUSIONS Observer performance for dose levels using 100-200 eff mAs was noninferior to that observed at 250 effective mAs with iterative reconstruction, with iterative reconstruction preserving noninferiority at a mean CT dose index of 15.2 mGy.
Collapse
|
18
|
Comparison of the Harms, Advantages, and Costs Associated With Alternative Guidelines for the Evaluation of Hematuria. JAMA Intern Med 2019; 179:1352-1362. [PMID: 31355874 PMCID: PMC6664383 DOI: 10.1001/jamainternmed.2019.2280] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
IMPORTANCE Existing recommendations for the diagnostic testing of hematuria range from uniform evaluation of varying intensity to patient-level risk stratification. Concerns have been raised about not only the costs and advantages of computed tomography (CT) scans but also the potential harms of CT radiation exposure. OBJECTIVE To compare the advantages, harms, and costs associated with 5 guidelines for hematuria evaluation. DESIGN, SETTING, AND PARTICIPANTS A microsimulation model was developed to assess each of the following guidelines (listed in order of increasing intensity) for initial evaluation of hematuria: Dutch, Canadian Urological Association (CUA), Kaiser Permanente (KP), Hematuria Risk Index (HRI), and American Urological Association (AUA). Participants comprised a hypothetical cohort of patients (n = 100 000) with hematuria aged 35 years or older. This study was conducted from August 2017 through November 2018. EXPOSURES Under the Dutch and CUA guidelines, patients received cystoscopy and ultrasonography if they were 50 years or older (Dutch) or 40 years or older (CUA). Under the KP and HRI guidelines, patients received different combinations of cystoscopy, ultrasonography, and CT urography or no evaluation on the basis of risk factors. Under the AUA guidelines, all patients 35 years or older received cystoscopy and CT urography. MAIN OUTCOMES AND MEASURES Urinary tract cancer detection rates, radiation-induced secondary cancers (from CT radiation exposure), procedural complications, false-positive rates per 100 000 patients, and incremental cost per additional urinary tract cancer detected. RESULTS The simulated cohort included 100 000 patients with hematuria, aged 35 years or older. A total of 3514 patients had urinary tract cancers (estimated prevalence, 3.5%; 95% CI, 3.0%-4.0%). The AUA guidelines missed detection for the fewest number of cancers (82 [2.3%]) compared with the detection rate of the HRI (116 [3.3%]) and KP (130 [3.7%]) guidelines. However, the simulation model projected 108 (95% CI, 34-201) radiation-induced cancers under the KP guidelines, 136 (95% CI, 62-229) under the HRI guidelines, and 575 (95% CI, 184-1069) under the AUA guidelines per 100 000 patients. The CUA and Dutch guidelines missed detection for a larger number of cancers (172 [4.9%] and 251 [7.1%]) but had 0 radiation-induced secondary cancers. The AUA guidelines cost approximately double the other 4 guidelines ($939/person vs $443/person for Dutch guidelines), with an incremental cost of $1 034 374 per urinary tract cancer detected compared with that of the HRI guidelines. CONCLUSIONS AND RELEVANCE In this simulation study, uniform CT imaging for patients with hematuria was associated with increased costs and harms of secondary cancers, procedural complications, and false positives, with only a marginal increase in cancer detection. Risk stratification may optimize the balance of advantages, harms, and costs of CT.
Collapse
|
19
|
Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography. Mol Imaging Radionucl Ther 2019; 28:96-103. [PMID: 31507141 PMCID: PMC6746012 DOI: 10.4274/mirt.galenos.2019.83723] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Objectives: The frequency of abdominal computed tomography examinations is increasing, leading to a significant level of patient dose. This study aims to quantify and evaluate the effects of automatic tube current modulation (ATCM) technique on patient dose and image quality in contrast-enhanced biphasic abdominal examinations. Methods: Two different scan protocols, based on constant tube current and ATCM technique, were used on 64 patients who visited our radiology department periodically. For three patient groups with different patient size, results from two protocols were compared with respect to patient dose and image quality. Dosimetric evaluations were based on the Computed Tomography Dose Index, dose length product, and effective dose. For the comparison of image qualities between two protocols, Noise Index (NI) and Contrast to Noise Ratio (CNR) values were determined for each image. Additionally, the quality of each image was evaluated subjectively by an experienced radiologist, and the results were compared between the two protocols. Results: Dose reductions of 31% and 21% were achieved by the ATCM protocol in the arterial and portal phases, respectively. On the other hand, NI exhibited an increase between 9% and 46% for liver, fat and aorta. CNR values were observed to decrease between 5% and 19%. All images were evaluated by a radiologist, and no obstacle limiting a reliable diagnostic evaluation was found in any image obtained by either technique. Conclusion: These results showed that the ATCM technique reduces patient dose significantly while maintaining a certain level of image quality.
Collapse
|
20
|
Diagnostic reference levels for paediatric CT in Jordan. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2019; 39:1060-1073. [PMID: 31469115 DOI: 10.1088/1361-6498/ab3ee2] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This study aimed to investigate the current status of Diagnostic Reference Levels (DRLs) in paediatric CT across Jordan. The dose data for four main CT examinations (brain, chest, abdominopelvic, and chest, abdomen and pelvis (CAP)) in hospitals and imaging centres (n = 4) were measured. The volume CT dose index (CTDIvol) and Dose Length Product (DLP) values were compared within the different hospitals and age groups (<1 year, 1-4 years, 5-10 years and 11-18 years). DRLs in Jordan were compared to international DRLs. The paediatric population consisted of 1818 children; 61.4% of them were male. There were significant variations between the DRLs for each CT scanner with an up to four-fold difference in dose between hospitals. There were apparent significant differences between Jordan and other countries with the DLPs in Jordan being relatively high. However, for CTDIvol, the values in Jordan were close to those of other countries. This study confirmed variations in the CTDIvol and DLP values of paediatric CT scans in Jordan. These variations were attributed to the different protocols and equipment used. There is a need to optimise paediatric CT examinations doses in Jordan.
Collapse
|
21
|
Computed Tomography Radiation Exposure Among Referred Kidney Stone Patients: Results from the Registry for Stones of the Kidney and Ureter. J Endourol 2019; 33:619-624. [PMID: 31030576 DOI: 10.1089/end.2019.0091] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Purpose: Kidney stone patients routinely have CT scans during diagnostic work-up before being referred to a tertiary center. How often these patients exceed the recommended dose limits for occupational radiation exposure of >100 mSv for 5 years and >50 mSv in a single year from CT alone remains unknown. This study aimed to quantify radiation doses from CTs received by stone patients before their evaluation at a tertiary care stone clinic. Methods: From November 2015 to March 2017, consecutive new patients enrolled into the Registry for Stones of the Kidney and Ureter (ReSKU™) had the dose-length product of every available CT abdomen/pelvis within 5 years of their initial visit recorded, allowing for an effective dose (EDose) calculation. Multivariate logistic regression analysis identified factors associated with exceeding recommended dose limits. Models were created to test radiation reducing effects of low-dose and phase-reduction CT protocols. Results: Of 343 noncontrast CTs performed, only 29 (8%) were low-dose CTs (calculated EDose <4 mSv). Among 389 total patients, 101 (26%) and 25 (6%) had an EDose >20 mSv and >50 mSv/year, respectively. Increased body mass index, number of scans, and multiphase scans were associated with exceeding exposure thresholds (p < 0.01). The implementation of a low-dose CT protocol decreased the estimated number of scans contributing to overexposure by >50%. Conclusions: Stone patients referred to a tertiary stone center may receive excessive radiation from CT scans alone. Unnecessary phases and underutilization of low-dose CT protocols continue to take place. Enacting new approaches to CT protocols may spare stone patients from exceeding recommended dose limits.
Collapse
|
22
|
CT diagnostic reference levels: are they appropriately computed? Eur Radiol 2019; 29:5264-5271. [PMID: 30963277 DOI: 10.1007/s00330-019-06141-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 02/18/2019] [Accepted: 03/08/2019] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To estimate the variability of CT diagnostic reference levels (DRLs) according to the methods used for computing collected data. METHODS Dose-length products (DLP) were collected by our national nuclear control agency from the 250 devices installed in 140 medical centers in the country. In 2015, the number of head, thorax, abdomen, and lumbar spine examinations collected in these centers ranged from approximately 20,000 to 42,000. The impact on DRLs of the number of devices considered, as well as the differences in descriptive statistics (mean vs. median DLP) or methods of pooling DLP data (all devices vs. all patients), was investigated. Variability in DRLs was investigated using a bootstrapping method as a function of the numbers of devices and examinations per device. RESULTS As expected, DRLs derived from means were higher than those from medians, with substantial differences between device- and patient-related DRLs. Depending on the numbers of devices and DLP data per device, the variability ranged from 10 to 40% but was stabilized at a level of 10-20% if the number of devices was higher than 50 to 60, regardless of the number of DLP data per device. CONCLUSION Number of devices and of DLP data per device, descriptive statistics, and pooling data influence DRLs. As differences in methods of computing survey data can artificially influence DRLs, harmonization among national authorities should be recommended. KEY POINTS • Due to CT dose variability, that of DRLs is at least of 10%. • DRLs derived from medians are lower than from means and differ from those obtained by pooling all patient data. • Fifty to 60 devices should be sufficient for estimating national DRLs, regardless of the number of data collected per device.
Collapse
|
23
|
Characterization of office laser printers for 3-D printing of soft tissue CT phantoms. J Med Imaging (Bellingham) 2019; 6:021602. [PMID: 30820442 DOI: 10.1117/1.jmi.6.2.021602] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 12/27/2018] [Indexed: 11/14/2022] Open
Abstract
The purpose of our study is to develop and evaluate a method for radiopaque 3-D printing (R3P) of soft tissue computed tomography (CT) phantoms with office laser printers. Five laser printers from different vendors are tested for toner CT attenuation. A liver phantom is created by printing CT images of a patient liver on office paper. One thousand eight hundred sixty paper sheets are printed with three repeated prints per page, resulting in a stack of 18.6 cm. The phantom is examined with 12 tube current settings. Images are reconstructed using filtered back projection (FBP) and iterative reconstruction [adaptive iterative dose reduction 3D (AIDR 3D)]. Seven radiologists rated image quality of all acquisitions. Toner attenuation of all investigated printers increased linearly with the print template grayscale. The liver phantom reproduced anatomic detail and attenuation values of the patient ( mean ± SD HU difference 12.68 ± 7.74 ). Image quality scores increased with dose but did not vary significantly above a threshold dose for AIDR 3D. Overall, AIDR 3D reconstructed images are rated superior to FBP reconstructions ( p < 0.001 ). In conclusion, R3P with standard office laser printers can generate soft tissue CT phantoms without hardware manipulations but with limited flexibility regarding attenuation properties of the printed toner material.
Collapse
|
24
|
Potential of a machine-learning model for dose optimization in CT quality assurance. Eur Radiol 2019; 29:3705-3713. [DOI: 10.1007/s00330-019-6013-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Accepted: 01/17/2019] [Indexed: 11/25/2022]
|
25
|
The effective and collective dose to patients undergoing abdominopelvic and trunk computed tomography examinations: A Belgian multicentre study. Eur J Radiol 2019; 111:81-87. [DOI: 10.1016/j.ejrad.2018.12.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 12/18/2018] [Accepted: 12/23/2018] [Indexed: 10/27/2022]
|
26
|
Abstract
OBJECTIVE To determine patient, institution, and machine characteristics that contribute to variation in radiation doses used for computed tomography (CT). DESIGN Prospective cohort study. SETTING Data were assembled and analyzed from the University of California San Francisco CT International Dose Registry. PARTICIPANTS Standardized data from over 2.0 million CT examinations of adults who underwent CT between November 2015 and August 2017 from 151 institutions, across seven countries (Switzerland, Netherlands, Germany, United Kingdom, United States, Israel, and Japan). MAIN OUTCOME MEASURES Mean effective doses and proportions of high dose examinations for abdomen, chest, combined chest and abdomen, and head CT were determined by patient characteristics (sex, age, and size), type of institution (trauma center, care provision 24 hours per day and seven days per week, academic, private), institutional practice volume, machine factors (manufacturer, model), country, and how scanners were used, before and after adjustment for patient characteristics, using hierarchical linear and logistic regression. High dose examinations were defined as CT scans with doses above the 75th percentile defined during a baseline period. RESULTS The mean effective dose and proportion of high dose examinations varied substantially across institutions. The doses varied modestly (10-30%) by type of institution and machine characteristics after adjusting for patient characteristics. By contrast, even after adjusting for patient characteristics, wide variations in radiation doses across countries persisted, with a fourfold range in mean effective dose for abdomen CT examinations (7.0-25.7 mSv) and a 17-fold range in proportion of high dose examinations (4-69%). Similar variation across countries was observed for chest (mean effective dose 1.7-6.4 mSv, proportion of high dose examinations 1-26%) and combined chest and abdomen CT (10.0-37.9 mSv, 2-78%). Doses for head CT varied less (1.4-1.9 mSv, 8-27%). In multivariable models, the dose variation across countries was primarily attributable to institutional decisions regarding technical parameters (that is, how the scanners were used). CONCLUSIONS CT protocols and radiation doses vary greatly across countries and are primarily attributable to local choices regarding technical parameters, rather than patient, institution, or machine characteristics. These findings suggest that the optimization of doses to a consistent standard should be possible. STUDY REGISTRATION Clinicaltrials.gov NCT03000751.
Collapse
|
27
|
Multiphase acquisitions in pediatric abdominal-pelvic CT are a common practice and contribute to unnecessary radiation dose. Pediatr Radiol 2018; 48:1714-1723. [PMID: 29980861 DOI: 10.1007/s00247-018-4192-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/23/2018] [Accepted: 06/18/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND Many patients at our pediatric hospital have had a contrast-enhanced CT of the abdomen and pelvis performed by an outside imaging facility before admission. We have noticed that many of these exams are multiphase, which may contribute to unnecessary radiation dose. OBJECTIVE To determine the frequency of multiphase acquisitions and radiation dose indices in contrast-enhanced CTs of the abdomen and pelvis performed by outside imaging facilities in patients who were subsequently transferred to our pediatric hospital for care, and compare these metrics to contrast-enhanced CTs of the abdomen and pelvis performed internally. MATERIALS AND METHODS A retrospective analysis was performed of contrast-enhanced CTs of the abdomen and pelvis from outside imaging facilities uploaded to our picture archiving and communication system (PACS) between January 1, 2012, and December 31, 2015. CT images and dose pages were reviewed to determine the number of phases and dose indices (CT dose index-volume [CTDIvol], dose-length product, size-specific dose estimate). Exams for abdominal or pelvic mass, trauma or urinary leak indications were excluded. Data were compared to internally acquired contrast-enhanced CTs of the abdomen and pelvis by querying the American College of Radiology (ACR) Dose Index Registry. This review was institutional review board and HIPAA compliant. RESULTS There were 754 contrast-enhanced CTs of the abdomen and pelvis from 104 outside imaging facilities. Fifty-three percent (399/754) had 2 phases, and 2% (14/754) had 3 or more phases. Of the 939 contrast-enhanced CTs of the abdomen and pelvis performed internally, 12% (115) were multiphase exams. Of 88% (664) contrast-enhanced CTs of the abdomen and pelvis from outside imaging facilities with dose data, CTDIvol was 2.7 times higher than our institution contrast-enhanced CTs of the abdomen and pelvis (939) for all age categories as defined by the ACR Dose Index Registry (mean: 9.4 vs. 3.5 mGy, P<0.0001). The majority (74%) of multiphase exams were performed by 9 of 104 outside imaging facilities. CONCLUSION Multiphase acquisitions in routine contrast-enhanced CT of the abdomen and pelvis exams at outside imaging facilities are more frequent than those at a dedicated pediatric institution and contribute to unnecessary radiation dose. A contrast-enhanced CT of the abdomen and pelvis exam from an outside imaging facility with two passes may have as much as four times to six times the dose as the same exam performed with a single pass at a pediatric imaging center. We advocate for imaging facilities with high multiphase rates to eliminate multiple phases from routine contrast-enhanced CT of the abdomen and pelvis exams in children.
Collapse
|
28
|
|
29
|
CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol. Cardiovasc Intervent Radiol 2018; 41:1751-1764. [PMID: 29789875 PMCID: PMC6182764 DOI: 10.1007/s00270-018-1979-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2018] [Accepted: 04/30/2018] [Indexed: 12/17/2022]
Abstract
Purpose The ALARA principle is not only relevant for effective dose (ED) reduction, but also applicable for contrast media (CM) management. Therefore, the aim was to evaluate the feasibility of an ultra-low CM protocol in the assessment of peripheral artery disease (PAD).
Materials and methods Fifty PAD patients were scanned on third-generation dual-source computed tomography, from diaphragm to the forefoot, as follows: tube voltage: 70 kV, reference effective tube current: 90 mAs, collimation: 192 × 2 × 0.6 mm, with individualized acquisition timing. The protocol ED (mSv) was quantified with dedicated software. CM protocol consisted of 15 ml test bolus and 30 ml main bolus (300 mgI/ml) injected at 5 ml/s, followed by a 40 ml saline chaser at the same flow rate. Aorto-popliteal bolus transit time was used to calculate the overall acquisition time and delay. Objective (hounsfield units—HU; contrast-to-noise ratio—CNR) and subjective image quality (four-point Likert score) were assessed at different anatomical regions from the aorta down to the forefoot. Results Mean attenuation values were exceeding 250 HU from aorta down to the anterior tibial artery with CNR < 13. However, decline in attenuation was observed in more distal region with mean values of 165 and 199 HU, in left and right dorsalis pedis artery, respectively. Mode subjective image quality from the level of aorta down to the popliteal segment was excellent; below the knee mode score was good. The mean ED per protocol was 1.1 ± 0.5 mSv. Conclusion Use of an ultra-low CM volume protocol at 70 kV is feasible in the evaluation of PAD, resulting in good to excellent image quality with mean ED of 1.1 ± 0.5 mSv. Level of evidence Level 3, Local non-random sample
Collapse
|
30
|
Quality and Safety of Obstetric Practices Using New Modalities— Ultrasound, MR, and CT. Clin Obstet Gynecol 2017; 60:546-561. [DOI: 10.1097/grf.0000000000000300] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
31
|
Patient characteristics associated with differences in radiation exposure from pediatric abdomen-pelvis CT scans: a quantile regression analysis. Comput Biol Med 2017; 85:7-12. [DOI: 10.1016/j.compbiomed.2017.04.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2017] [Revised: 03/27/2017] [Accepted: 04/11/2017] [Indexed: 10/19/2022]
|
32
|
Abstract
IMPORTANCE Radiation doses for computed tomography (CT) vary substantially across institutions. OBJECTIVE To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. DESIGN, SETTING, AND PARTICIPANTS In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. MAIN OUTCOMES AND MEASURES We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. RESULTS Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After the audit and meeting, head CT doses varied less, although some institutions increased and some decreased mean head CT doses and the proportion above benchmarks. CONCLUSIONS AND RELEVANCE Reviewing institutional doses and sharing dose-optimization best practices resulted in lower radiation doses for chest and abdominal CT and more consistent doses for head CT.
Collapse
|