1
|
Abdelaziz MEMK, Tian L, Lottner T, Reiss S, Heidt T, Maier A, Düring K, von zur Mühlen C, Bock M, Yeatman E, Yang G, Temelkuran B. Thermally Drawn Polymeric Catheters for MR-Guided Cardiovascular Intervention. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2407704. [PMID: 39403885 PMCID: PMC11615795 DOI: 10.1002/advs.202407704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 08/31/2024] [Indexed: 12/06/2024]
Abstract
Cardiovascular diseases (CVDs), including congenital heart diseases (CHD), present significant global health challenges, emphasizing the need for safe and effective treatment modalities. Fluoroscopy-guided endovascular interventions are widely utilized but raise concerns about ionizing radiation, especially in pediatric cases. Magnetic resonance imaging (MRI) offers a radiation-free alternative with superior soft tissue visualization and functional insights. However, the lack of compatible instruments remains a major obstacle. An adapted thermal drawing platform that enables low-cost and rapid prototyping of instruments for MR-guided endovascular interventions is introduced. This platform is demonstrated through the development of two exemplary catheter systems: a tendon-driven steerable catheter with helical lumina and an active tracking Tiger-shaped catheter with an embedded coaxial wire. These catheters exhibit mechanical properties comparable to commercial counterparts and show promising outcomes in both in vitro and in vivo feasibility testing. This scalable thermal drawing platform addresses the limitations of existing manufacturing approaches and facilitates the exploration of diverse designs, potentially accelerating advancements in catheter technologies for MR-guided cardiovascular interventions.
Collapse
Affiliation(s)
- Mohamed E. M. K. Abdelaziz
- The Hamlyn Centre for Robotic SurgeryImperial College LondonLondonSW7 2AZUK
- Department of Electrical and Electronic EngineeringFaculty of EngineeringImperial College LondonLondonSW7 2AZUK
| | - Libaihe Tian
- The Hamlyn Centre for Robotic SurgeryImperial College LondonLondonSW7 2AZUK
- Department of MetabolismDigestion, and ReproductionFaculty of MedicineImperial College LondonLondonSW7 2AZUK
| | - Thomas Lottner
- Department of Diagnostic and Interventional RadiologyMedical PhysicsFaculty of Medicine, University of Freiburg79106FreiburgGermany
| | - Simon Reiss
- Department of Diagnostic and Interventional RadiologyMedical PhysicsFaculty of Medicine, University of Freiburg79106FreiburgGermany
| | - Timo Heidt
- Department of Cardiology and AngiologyUniversity Heart Center Freiburg – Bad KrozingenFaculty of MedicineUniversity of Freiburg79106FreiburgGermany
| | - Alexander Maier
- Department of Cardiology and AngiologyUniversity Heart Center Freiburg – Bad KrozingenFaculty of MedicineUniversity of Freiburg79106FreiburgGermany
| | - Klaus Düring
- MaRVis Interventional GmbH82467Garmisch‐PartenkirchenGermany
| | - Constantin von zur Mühlen
- Department of Cardiology and AngiologyUniversity Heart Center Freiburg – Bad KrozingenFaculty of MedicineUniversity of Freiburg79106FreiburgGermany
| | - Michael Bock
- Department of Diagnostic and Interventional RadiologyMedical PhysicsFaculty of Medicine, University of Freiburg79106FreiburgGermany
| | - Eric Yeatman
- Department of Electrical and Electronic EngineeringFaculty of EngineeringImperial College LondonLondonSW7 2AZUK
| | - Guang‐Zhong Yang
- Institute of Medical RobotsShanghai Jiao Tong UniversityShanghai200240China
| | - Burak Temelkuran
- The Hamlyn Centre for Robotic SurgeryImperial College LondonLondonSW7 2AZUK
- Department of MetabolismDigestion, and ReproductionFaculty of MedicineImperial College LondonLondonSW7 2AZUK
- The Rosalind Franklin InstituteDidcotOX11 0QSUK
| |
Collapse
|
2
|
Voges I, Raimondi F, McMahon CJ, Ait-Ali L, Babu-Narayan SV, Botnar RM, Burkhardt B, Gabbert DD, Grosse-Wortmann L, Hasan H, Hansmann G, Helbing WA, Krupickova S, Latus H, Martini N, Martins D, Muthurangu V, Ojala T, van Ooij P, Pushparajah K, Rodriguez-Palomares J, Sarikouch S, Grotenhuis HB, Greil FG, Bohbot Y, Cikes M, Dweck M, Donal E, Grapsa J, Keenan N, Petrescu AM, Szabo L, Ricci F, Uusitalo V. Clinical impact of novel cardiovascular magnetic resonance technology on patients with congenital heart disease: a scientific statement of the Association for European Pediatric and Congenital Cardiology and the European Association of Cardiovascular Imaging of the European Society of Cardiology. Eur Heart J Cardiovasc Imaging 2024; 25:e274-e294. [PMID: 38985851 DOI: 10.1093/ehjci/jeae172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Accepted: 07/01/2024] [Indexed: 07/12/2024] Open
Abstract
Cardiovascular magnetic resonance (CMR) imaging is recommended in patients with congenital heart disease (CHD) in clinical practice guidelines as the imaging standard for a large variety of diseases. As CMR is evolving, novel techniques are becoming available. Some of them are already used clinically, whereas others still need further evaluation. In this statement, the authors give an overview of relevant new CMR techniques for the assessment of CHD. Studies with reference values for these new techniques are listed in the Supplementary data online, supplement.
Collapse
Affiliation(s)
- Inga Voges
- Department of Congenital Heart Disease and Pediatric Cardiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Kiel, Germany
| | | | - Colin J McMahon
- Department of Paediatric Cardiology, Children's Health Ireland at Crumlin, Dublin 12, Ireland
| | - Lamia Ait-Ali
- Institute of Clinical Physiology CNR, Massa, Italy
- Heart Hospital, G. Monastery foundation, Massa, Italy
| | - Sonya V Babu-Narayan
- Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, London, UK
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
- Institute for Biological and Medical Engineering and School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Barbara Burkhardt
- Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Dominik D Gabbert
- Department of Congenital Heart Disease and Pediatric Cardiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Kiel, Germany
| | - Lars Grosse-Wortmann
- Division of Cardiology, Oregon Health and Science University Hospital, Portland, OR, USA
| | - Hosan Hasan
- Department of Pediatric Cardiology and Critical Care, Hannover Medical School, Hannover, Germany
- European Pediatric Pulmonary Vascular Disease Network, Berlin, Germany
| | - Georg Hansmann
- Department of Pediatric Cardiology and Critical Care, Hannover Medical School, Hannover, Germany
- European Pediatric Pulmonary Vascular Disease Network, Berlin, Germany
| | - Willem A Helbing
- Department of Pediatrics, Division of Cardiology, and Department of Radiology, Erasmus MC-Sophia Children's Hospital, Rotterdam, The Netherlands
| | - Sylvia Krupickova
- Royal Brompton Hospital, Part of Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, Imperial College, London, UK
- Department of Paediatric Cardiology, Royal Brompton Hospital, Sydney Street, London SW3 6NP, UK
| | - Heiner Latus
- Clinic for Pediatric Cardiology and Congenital Heart Disease Klinikum, Stuttgart Germany
| | - Nicola Martini
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
- U.O.C. Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, Pisa, Italy
| | - Duarte Martins
- Pediatric Cardiology Department, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal
| | - Vivek Muthurangu
- Centre for Translational Cardiovascular Imaging, Institute of Cardiovascular Science, University College London, London, UK
| | - Tiina Ojala
- New Children's Hospital Pediatric Research Center, Helsinki University Hospital, Helsinki, Finland
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Location AMC, Amsterdam, The Netherlands
- Department of Pediatric Cardiology, Wilhelmina Children's Hospital/University Medical Center Utrecht, Utrecht, The Netherlands
| | - Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
- Department of Congenital Heart Disease, Evelina London Children's Hospital, Westminster Bridge Road, London SE1 7EH, UK
| | - Jose Rodriguez-Palomares
- CIBER Cardiovascular, Instituto de Salud Carlos III, Madrid, Spain
- European Reference Network for Rare and Low Prevalence Complex Diseases of the Heart, Amsterdam, The Netherlands
- Servicio de Cardiología, Hospital Universitario Vall Hebrón, Institut de Recerca Vall Hebrón (VHIR), Departamento de Medicina, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Samir Sarikouch
- Department for Cardiothoracic, Transplant, and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Heynric B Grotenhuis
- Department of Pediatric Cardiology, Wilhelmina Children's Hospital/University Medical Center Utrecht, Utrecht, The Netherlands
| | - F Gerald Greil
- Department of Pediatrics, UT Southwestern/Children's Health, Dallas, TX, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Nijsink H, Overduin CG, Willems LH, Warlé MC, Fütterer JJ. Current State of MRI-Guided Endovascular Arterial Interventions: A Systematic Review of Preclinical and Clinical Studies. J Magn Reson Imaging 2022; 56:1322-1342. [PMID: 35420239 PMCID: PMC9790618 DOI: 10.1002/jmri.28205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 04/04/2022] [Accepted: 04/04/2022] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND MRI guidance of arterial endovascular interventions could be beneficial as it does not require radiation exposure, allows intrinsic blood-tissue contrast, and enables three-dimensional and functional imaging, however, clinical applications are still limited. PURPOSE To review the current state of MRI-guided arterial endovascular interventions and to identify the most commonly reported challenges. STUDY TYPE Systematic review. POPULATION Pubmed, Embase, Web of Science, and The Cochrane Library were systematically searched to find relevant articles. The search strategy combined synonyms for vascular pathology, endovascular therapy, and real-time MRI guidance. FIELD STRENGTH/SEQUENCE No field strength or sequence restrictions were applied. ASSESSMENT Two reviewers independently identified and reviewed the original articles and extracted relevant data. STATISTICAL TESTS Results of the included original articles are reported. RESULTS A total of 24,809 studies were identified for screening. Eighty-eight studies were assessed for eligibility, after which data were extracted from 43 articles (6 phantom, 33 animal, and 4 human studies). Reported technical success rates for animal and human studies ranged between 42% to 100%, and the average complication rate was 5.8% (animal studies) and 8.8% (human studies). Main identified challenges were related to spatial and temporal resolution as well as safety, design, and scarcity of current MRI-compatible endovascular devices. DATA CONCLUSION MRI guidance of endovascular arterial interventions seems feasible, however, included articles included mostly small single-center case series. Several hurdles remain to be overcome before larger trials can be undertaken. Main areas of research should focus on adequate imaging protocols with integrated tracking of dedicated endovascular devices.
Collapse
Affiliation(s)
- Han Nijsink
- Department of Medical ImagingRadboudumcNijmegenNetherlands
| | | | | | | | | |
Collapse
|
4
|
Kilbride BF, Narsinh KH, Jordan CD, Mueller K, Moore T, Martin AJ, Wilson MW, Hetts SW. MRI-guided endovascular intervention: current methods and future potential. Expert Rev Med Devices 2022; 19:763-778. [PMID: 36373162 PMCID: PMC9869980 DOI: 10.1080/17434440.2022.2141110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 10/25/2022] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Image-guided endovascular interventions, performed using the insertion and navigation of catheters through the vasculature, have been increasing in number over the years, as minimally invasive procedures continue to replace invasive surgical procedures. Such endovascular interventions are almost exclusively performed under x-ray fluoroscopy, which has the best spatial and temporal resolution of all clinical imaging modalities. Magnetic resonance imaging (MRI) offers unique advantages and could be an attractive alternative to conventional x-ray guidance, but also brings with it distinctive challenges. AREAS COVERED In this review, the benefits and limitations of MRI-guided endovascular interventions are addressed, systems and devices for guiding such interventions are summarized, and clinical applications are discussed. EXPERT OPINION MRI-guided endovascular interventions are still relatively new to the interventional radiology field, since significant technical hurdles remain to justify significant costs and demonstrate safety, design, and robustness. Clinical applications of MRI-guided interventions are promising but their full potential may not be realized until proper tools designed to function in the MRI environment are available. Translational research and further preclinical studies are needed before MRI-guided interventions will be practical in a clinical interventional setting.
Collapse
Affiliation(s)
- Bridget F. Kilbride
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Kazim H. Narsinh
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | | | | | - Teri Moore
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Alastair J. Martin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Mark W. Wilson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Steven W. Hetts
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
5
|
Godinez F, Tomi-Tricot R, Delcey M, Williams SE, Mooiweer R, Quesson B, Razavi R, Hajnal JV, Malik SJ. Interventional cardiac MRI using an add-on parallel transmit MR system: In vivo experience in sheep. Magn Reson Med 2021; 86:3360-3372. [PMID: 34286866 DOI: 10.1002/mrm.28931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 06/15/2021] [Accepted: 06/28/2021] [Indexed: 12/19/2022]
Abstract
PURPOSE We present in vivo testing of a parallel transmit system intended for interventional MR-guided cardiac procedures. METHODS The parallel transmit system was connected in-line with a conventional 1.5 Tesla MRI system to transmit and receive on an 8-coil array. The system used a current sensor for real-time feedback to achieve real-time current control by determining coupling and null modes. Experiments were conducted on 4 Charmoise sheep weighing 33.9-45.0 kg with nitinol guidewires placed under X-ray fluoroscopy in the atrium or ventricle of the heart via the femoral vein. Heating tests were done in vivo and post-mortem with a high RF power imaging sequence using the coupling mode. Anatomical imaging was done using a combination of null modes optimized to produce a useable B1 field in the heart. RESULTS Anatomical imaging produced cine images of the heart comparable in quality to imaging with the quad mode (all channels with the same amplitude and phase). Maximum observed temperature increases occurred when insulation was stripped from the wire tip. These were 4.1℃ and 0.4℃ for the coupling mode and null modes, respectively for the in vivo case; increasing to 6.0℃ and 1.3℃, respectively for the ex vivo case, because cooling from blood flow is removed. Heating < 0.1℃ was observed when insulation was not stripped from guidewire tips. In all tests, the parallel transmit system managed to reduce the temperature at the guidewire tip. CONCLUSION We have demonstrated the first in vivo usage of an auxiliary parallel transmit system employing active feedback-based current control for interventional MRI with a conventional MRI scanner.
Collapse
Affiliation(s)
- Felipe Godinez
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Raphael Tomi-Tricot
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Marylène Delcey
- Centre de Recherche Cardio, Thoracique de Bordeaux/IHU Liryc, INSERM U1045-University of Bordeaux, Pessac, France.,Siemens Healthcare, Saint-Denis, France
| | - Steven E Williams
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Ronald Mooiweer
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Bruno Quesson
- Centre de Recherche Cardio, Thoracique de Bordeaux/IHU Liryc, INSERM U1045-University of Bordeaux, Pessac, France
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Joseph V Hajnal
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Shaihan J Malik
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
6
|
Stephan S, Reiss S, Lottner T, Özen AC, Bock M. Catheter-based Arterial Input Function Determination for Myocardial Perfusion Measurements. Z Med Phys 2021; 31:65-72. [PMID: 32873440 DOI: 10.1016/j.zemedi.2020.07.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 07/23/2020] [Accepted: 07/23/2020] [Indexed: 10/23/2022]
Abstract
The quantification of myocardial perfusion with contrast agent (CA) tracers requires the precise knowledge of the arterial input function (AIF). In this study a method for MR-guided vascular interventions is evaluated that determines the AIF via an active tracking catheter during targeted CA injection. A phantom experiment with a dialysis filter was conducted to measure the AIF using an active catheter and a dynamic image series as reference. To compensate for dilution and coil sensitivity effects, correction methods were developed for the catheter-based AIF determination. From the dynamic MR measurements in the perfusion phantom quantitative perfusion maps were calculated by a deconvolution of the measured CA concentration with the AIF, and additional flow measurements were used to normalize the perfusion map. The signal-time-curves of the measured AIF using the catheter-based and imaging-based methods agree while the absolute values differ by a scaling factor of about 9. After normalization to the surrounding flow, both perfusion techniques are in excellent agreement. Catheter-based AIF measurements are feasible but require an additional normalization which can be determined from a flow measurement. The technique might enable faster perfusion measurements during cardiovascular interventions.
Collapse
Affiliation(s)
- Simon Stephan
- Department of Radiology - Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Simon Reiss
- Department of Radiology - Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Lottner
- Department of Radiology - Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ali Caglar Özen
- Department of Radiology - Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Department of Radiology - Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| |
Collapse
|
7
|
Chen F, Liu J, Zhang X, Zhang D, Liao H. Improved 3D Catheter Shape Estimation Using Ultrasound Imaging for Endovascular Navigation: A Further Study. IEEE J Biomed Health Inform 2020; 24:3616-3629. [PMID: 32966224 DOI: 10.1109/jbhi.2020.3026105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Two-dimensional fluoroscopy is the standard guidance imaging method for closed endovascular intervention. However, two-dimensional fluoroscopy lacks depth perception for the intervention catheter and causes radiation exposure for both surgeons and patients. In this paper, we extend our previous study and develop the improved three-dimensional (3D) catheter shape estimation using ultrasound imaging. In addition, we perform further quantitative evaluations of endovascular navigation. METHOD First, the catheter tracking accuracy in ultrasound images is improved by adjusting the state vector and adding direction information. Then, the 3D catheter points from the catheter tracking are further optimized based on the 3D catheter shape optimization with a high-quality sample set. Finally, the estimated 3D catheter shapes from ultrasound images are overlaid with preoperative 3D tissue structures for the intuitive endovascular navigation. RESULTS the tracking accuracy of the catheter increased by 24.39%, and the accuracy of the catheter shape optimization step also increased by approximately 17.34% compared with our previous study. Furthermore, the overall error of catheter shape estimation was further validated in the catheter intervention experiment of in vitro cardiovascular tissue and in a vivo swine, and the errors were 2.13 mm and 3.37 mm, respectively. CONCLUSION Experimental results demonstrate that the improved catheter shape estimation using ultrasound imaging is accurate and appropriate for endovascular navigation. SIGNIFICANCE Improved navigation reduces the radiation risk because it decreases use of X-ray imaging. In addition, this navigation method can also provide accurate 3D catheter shape information for endovascular surgery.
Collapse
|
8
|
|
9
|
Heidt T, Reiss S, Lottner T, Özen AC, Bode C, Bock M, von Zur Mühlen C. Magnetic resonance imaging for pathobiological assessment and interventional treatment of the coronary arteries. Eur Heart J Suppl 2020; 22:C46-C56. [PMID: 32368198 PMCID: PMC7189741 DOI: 10.1093/eurheartj/suaa009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
X-ray-based fluoroscopy is the standard tool for diagnostics and intervention in coronary artery disease. In recent years, computed tomography has emerged as a non-invasive alternative to coronary angiography offering detection of coronary calcification and imaging of the vessel lumen by the use of iodinated contrast agents. Even though currently available invasive or non-invasive techniques can show the degree of vessel stenosis, they are unable to provide information about biofunctional plaque properties, e.g. plaque inflammation. Furthermore, the use of radiation and the necessity of iodinated contrast agents remain unfavourable prerequisites. Magnetic resonance imaging (MRI) is a radiation-free alternative to X-ray which offers anatomical and functional imaging contrasts fostering the idea of non-invasive biofunctional assessment of the coronary vessel wall. In combination with molecular contrast agents that target-specific epitopes of the vessel wall, MRI might reveal unique plaque properties rendering it, for example, ‘vulnerable and prone to rupture’. Early detection of these lesions may allow for early or prophylactic treatment even before an adverse coronary event occurs. Besides diagnostic imaging, advances in real-time image acquisition and motion compensation now provide grounds for MRI-guided coronary interventions. In this article, we summarize our research on MRI-based molecular imaging in cardiovascular disease and feature our advances towards real-time MRI-based coronary interventions in a porcine model.
Collapse
Affiliation(s)
- Timo Heidt
- Department of Cardiology, Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Hugstetterstr. 55, 79106 Freiburg, Germany
| | - Simon Reiss
- Department of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Thomas Lottner
- Department of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Ali C Özen
- Department of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.,German Cancer Consortium Partner Site Freiburg, German Cancer Research Center (DKFZ), Stefan-Meier-Str. 17, 79104 Freiburg, Germany
| | - Christoph Bode
- Department of Cardiology, Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Hugstetterstr. 55, 79106 Freiburg, Germany
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Constantin von Zur Mühlen
- Department of Cardiology, Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Hugstetterstr. 55, 79106 Freiburg, Germany
| |
Collapse
|
10
|
Real-time 3T MRI-guided cardiovascular catheterization in a porcine model using a glass-fiber epoxy-based guidewire. PLoS One 2020; 15:e0229711. [PMID: 32102092 PMCID: PMC7043930 DOI: 10.1371/journal.pone.0229711] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 02/13/2020] [Indexed: 11/19/2022] Open
Abstract
PURPOSE Real-time magnetic resonance imaging (MRI) is a promising alternative to X-ray fluoroscopy for guiding cardiovascular catheterization procedures. Major challenges, however, include the lack of guidewires that are compatible with the MRI environment, not susceptible to radiofrequency-induced heating, and reliably visualized. Preclinical evaluation of new guidewire designs has been conducted at 1.5T. Here we further evaluate the safety (device heating), device visualization, and procedural feasibility of 3T MRI-guided cardiovascular catheterization using a novel MRI-visible glass-fiber epoxy-based guidewire in phantoms and porcine models. METHODS To evaluate device safety, guidewire tip heating (GTH) was measured in phantom experiments with different combinations of catheters and guidewires. In vivo cardiovascular catheterization procedures were performed in both healthy (N = 5) and infarcted (N = 5) porcine models under real-time 3T MRI guidance using a glass-fiber epoxy-based guidewire. The times for each procedural step were recorded separately. Guidewire visualization was assessed by measuring the dimensions of the guidewire-induced signal void and contrast-to-noise ratio (CNR) between the guidewire tip signal void and the blood signal in real-time gradient-echo MRI (specific absorption rate [SAR] = 0.04 W/kg). RESULTS In the phantom experiments, GTH did not exceed 0.35°C when using the real-time gradient-echo sequence (SAR = 0.04 W/kg), demonstrating the safety of the glass-fiber epoxy-based guidewire at 3T. The catheter was successfully placed in the left ventricle (LV) under real-time MRI for all five healthy subjects and three out of five infarcted subjects. Signal void dimensions and CNR values showed consistent visualization of the glass-fiber epoxy-based guidewire in real-time MRI. The average time (minutes:seconds) for the catheterization procedure in all subjects was 4:32, although the procedure time varied depending on the subject's specific anatomy (standard deviation = 4:41). CONCLUSIONS Real-time 3T MRI-guided cardiovascular catheterization using a new MRI-visible glass-fiber epoxy-based guidewire is feasible in terms of visualization and guidewire navigation, and safe in terms of radiofrequency-induced guidewire tip heating.
Collapse
|
11
|
Neumann W, Pusch TP, Siegfarth M, Schad LR, Stallkamp JL. CT and MRI compatibility of flexible 3D-printed materials for soft actuators and robots used in image-guided interventions. Med Phys 2019; 46:5488-5498. [PMID: 31587313 DOI: 10.1002/mp.13852] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 08/12/2019] [Accepted: 09/26/2019] [Indexed: 01/09/2023] Open
Abstract
PURPOSE Three-dimensional (3D) printing allows for the fabrication of medical devices with complex geometries, such as soft actuators and robots that can be used in image-guided interventions. This study investigates flexible and rigid 3D-printing materials in terms of their impact on multimodal medical imaging. METHODS The generation of artifacts in clinical computer tomography (CT) and magnetic resonance (MR) imaging was evaluated for six flexible and three rigid materials, each with a cubical and a cylindrical geometry, and for one exemplary flexible fluidic actuator. Additionally, CT Hounsfield units (HU) were quantified for various parameter sets iterating peak voltage, x-ray tube current, slice thickness, and convolution kernel. RESULTS We found the image artifacts caused by the materials to be negligible in both CT and MR images. The HU values mainly depended on the elemental composition of the materials and applied peak voltage was ranging between 80 and 140 kVp. Flexible, nonsilicone-based materials were ranged between 51 and 114 HU. The voltage dependency was less than 29 HU. Flexible, silicone-based materials were ranged between 60 and 365 HU. The voltage-dependent influence was as large as 172 HU. Rigid materials ranged between -69 and 132 HU. The voltage-dependent influence was <33 HU. CONCLUSIONS All tested materials may be employed for devices placed in the field of view during CT and MR imaging as no significant artifacts were measured. Moreover, the material selection in CT could be based on the desired visibility of the material depending on the application. Given the wide availability of the tested materials, we expect our results to have a positive impact on the development of devices and robots for image-guided interventions.
Collapse
Affiliation(s)
- Wiebke Neumann
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany
| | - Tim P Pusch
- Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, 68167, Mannheim, Germany
| | - Marius Siegfarth
- Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, 68167, Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany
| | - Jan L Stallkamp
- Fraunhofer Institute for Manufacturing Engineering and Automation, Project Group for Automation in Medicine and Biotechnology, 68167, Mannheim, Germany.,Medical Faculty Mannheim, Heidelberg University, 68167, Mannheim, Germany
| |
Collapse
|
12
|
Heidt T, Reiss S, Krafft AJ, Özen AC, Lottner T, Hehrlein C, Galmbacher R, Kayser G, Hilgendorf I, Stachon P, Wolf D, Zirlik A, Düring K, Zehender M, Meckel S, von Elverfeldt D, Bode C, Bock M, von Zur Mühlen C. Real-time magnetic resonance imaging - guided coronary intervention in a porcine model. Sci Rep 2019; 9:8663. [PMID: 31209241 PMCID: PMC6572773 DOI: 10.1038/s41598-019-45154-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 06/03/2019] [Indexed: 11/28/2022] Open
Abstract
X-ray fluoroscopy is the gold standard for coronary diagnostics and intervention. Magnetic resonance imaging is a radiation-free alternative to x-ray with excellent soft tissue contrast in arbitrary slice orientation. Here, we assessed real-time MRI-guided coronary interventions from femoral access using newly designed MRI technologies. Six Goettingen minipigs were used to investigate coronary intervention using real-time MRI. Catheters were custom-designed and equipped with an active receive tip-coil to improve visibility and navigation capabilities. Using modified standard clinical 5 F catheters, intubation of the left coronary ostium was successful in all animals. For the purpose of MR-guided coronary interventions, a custom-designed 8 F catheter was used. In spite of the large catheter size, and therefore limited steerability, intubation of the left coronary ostium was successful in 3 of 6 animals within seconds. Thereafter, real-time guided implantation of a non-metallic vascular scaffold into coronary arteries was possible. This study demonstrates that real-time MRI-guided coronary catheterization and intervention via femoral access is possible without the use of any contrast agents or radiation, including placement of non-metallic vascular scaffolds into coronary arteries. Further development, especially in catheter and guidewire technology, will be required to drive forward routine MR-guided coronary interventions as an alternative to x-ray fluoroscopy.
Collapse
Affiliation(s)
- Timo Heidt
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany.
| | - Simon Reiss
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Axel J Krafft
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Ali Caglar Özen
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Thomas Lottner
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Christoph Hehrlein
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Roland Galmbacher
- Department of Experimental Anesthesiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Gian Kayser
- Department of Pathology, Institute of Surgical Pathology, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Ingo Hilgendorf
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Peter Stachon
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Dennis Wolf
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Andreas Zirlik
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | | | - Manfred Zehender
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Stephan Meckel
- Department of Neuroradiology, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Dominik von Elverfeldt
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Christoph Bode
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| | - Michael Bock
- Department of Radiology, Medical Physics, University Medical Center Freiburg, Faculty of Medicine, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Cardiology and Angiology I, Heart Center Freiburg University and Faculty of Medicine, Freiburg, Germany
| |
Collapse
|
13
|
Campbell-Washburn AE, Rogers T, Stine AM, Khan JM, Ramasawmy R, Schenke WH, McGuirt DR, Mazal JR, Grant LP, Grant EK, Herzka DA, Lederman RJ. Right heart catheterization using metallic guidewires and low SAR cardiovascular magnetic resonance fluoroscopy at 1.5 Tesla: first in human experience. J Cardiovasc Magn Reson 2018; 20:41. [PMID: 29925397 PMCID: PMC6011242 DOI: 10.1186/s12968-018-0458-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 05/10/2018] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) fluoroscopy allows for simultaneous measurement of cardiac function, flow and chamber pressure during diagnostic heart catheterization. To date, commercial metallic guidewires were considered contraindicated during CMR fluoroscopy due to concerns over radiofrequency (RF)-induced heating. The inability to use metallic guidewires hampers catheter navigation in patients with challenging anatomy. Here we use low specific absorption rate (SAR) imaging from gradient echo spiral acquisitions and a commercial nitinol guidewire for CMR fluoroscopy right heart catheterization in patients. METHODS The low-SAR imaging protocol used a reduced flip angle gradient echo acquisition (10° vs 45°) and a longer repetition time (TR) spiral readout (10 ms vs 2.98 ms). Temperature was measured in vitro in the ASTM 2182 gel phantom and post-mortem animal experiments to ensure freedom from heating with the selected guidewire (150 cm × 0.035″ angled-tip nitinol Terumo Glidewire). Seven patients underwent CMR fluoroscopy catheterization. Time to enter each chamber (superior vena cava, main pulmonary artery, and each branch pulmonary artery) was recorded and device visibility and confidence in catheter and guidewire position were scored on a Likert-type scale. RESULTS Negligible heating (< 0.07°C) was observed under all in vitro conditions using this guidewire and imaging approach. In patients, chamber entry was successful in 100% of attempts with a guidewire compared to 94% without a guidewire, with failures to reach the branch pulmonary arteries. Time-to-enter each chamber was similar (p=NS) for the two approaches. The guidewire imparted useful catheter shaft conspicuity and enabled interactive modification of catheter shaft stiffness, however, the guidewire tip visibility was poor. CONCLUSIONS Under specific conditions, trained operators can apply low-SAR imaging and using a specific fully-insulated metallic nitinol guidewire (150 cm × 0.035" Terumo Glidewire) to augment clinical CMR fluoroscopy right heart catheterization. TRIAL REGISTRATION Clinicaltrials.gov NCT03152773 , registered May 15, 2017.
Collapse
Affiliation(s)
- Adrienne E. Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Annette M. Stine
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Delaney R. McGuirt
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Jonathan R. Mazal
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Laurie P. Grant
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Elena K. Grant
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Daniel A. Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD 20892-1538 USA
| |
Collapse
|
14
|
Schleicher KE, Bock M, Düring K, Kroboth S, Krafft AJ. Radial MRI with variable echo times: reducing the orientation dependency of susceptibility artifacts of an MR-safe guidewire. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:235-242. [PMID: 28770356 DOI: 10.1007/s10334-017-0645-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 07/20/2017] [Accepted: 07/21/2017] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Guidewires are indispensable tools for intravascular MR-guided interventions. Recently, an MR-safe guidewire made from a glass-fiber/epoxy compound material with embedded iron particles was developed. The size of the induced susceptibility artifact, and thus the guidewire's visibility, depends on its orientation against B 0. We present a radial acquisition scheme with variable echo times that aims to reduce the artifact's orientation dependency. MATERIALS AND METHODS The radial acquisition scheme uses sine-squared modulated echo times depending on the physical direction of the spoke to balance the susceptibility artifact of the guidewire. The acquisition scheme was studied in simulations based on dipole fields and in phantom experiments for different orientations of the guidewire against B 0. The simulated and measured artifact widths were quantitatively compared. RESULTS Compared to acquisitions with non-variable echo times, the proposed acquisition scheme shows a reduced angular variability. For the two main orientations (i.e., parallel and perpendicular to B 0), the ratio of the artifact widths was reduced from about 2.2 (perpendicular vs. parallel) to about 1.2 with the variable echo time approach. CONCLUSION The reduction of the orientation dependency of the guidewire's artifact via sine-squared varying echo times could be verified in simulations and measurements. The more balanced artifact allows for a better overall visibility of the guidewire.
Collapse
Affiliation(s)
- Katharina E Schleicher
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany.
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany
| | | | - Stefan Kroboth
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany
| | - Axel J Krafft
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Strasse 60a, 79106, Freiburg, Germany
| |
Collapse
|