1
|
Maltepe E, Smith M, Boehme J, Datar SA, Hutchings RS, Vento CA, Manzoor H, Loucks A, Winger JA, Fineman JR. OMX: A NOVEL OXYGEN DELIVERY BIOTHERAPEUTIC IMPROVES OUTCOMES IN AN OVINE MODEL OF CONTROLLED HEMORRHAGIC SHOCK. Shock 2024; 62:103-110. [PMID: 38662597 DOI: 10.1097/shk.0000000000002356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2024]
Abstract
ABSTRACT Hemorrhagic shock is a major source of morbidity and mortality worldwide. While whole blood or blood product transfusion is a first-line treatment, maintaining robust supplies presents significant logistical challenges, particularly in austere environments. OMX is a novel nonhemoglobin (Hb)-based oxygen carrier derived from the H-NOX (heme-nitric oxide/oxygen binding) protein family. Because of their engineered oxygen (O 2 ) affinities, OMX proteins only deliver O 2 to severely hypoxic tissues. Additionally, unlike Hb-based oxygen carriers, OMX proteins do not scavenge nitric oxide in the vasculature. To determine the safety and efficacy of OMX in supporting tissue oxygen delivery and cardiovascular function in a large animal model of controlled hemorrhage, 2-3-week-old lambs were anesthetized, intubated, and mechanically ventilated. Hypovolemic shock was induced by acute hemorrhage to obtain a 50% reduction over 30 min. Vehicle (n = 16) or 400 mg/kg OMX (n = 13) treatment was administered over 15 min. Hemodynamics, arterial blood gases, and laboratory values were monitored throughout the 6-h study. Comparisons between groups were made using t tests, Wilcoxon rank sum test, and Fisher's exact test. Survival was assessed using Kaplan-Meier curves and the log-rank test. We found that OMX was well-tolerated and significantly improved lactate and base deficit trends, and hemodynamic indices ( P < 0.05). Median survival time was greater in the OMX-treated group (4.7 vs. 6.0 h, P < 0.003), and overall survival was significantly increased in the OMX-treated group (25% vs. 85%, P = 0.004). We conclude that OMX is well-tolerated and improves metabolic, hemodynamic, and survival outcomes in an ovine model of controlled hemorrhagic shock.
Collapse
Affiliation(s)
| | | | - Jason Boehme
- Department of Pediatrics, UCSF, San Francisco, CA
| | | | | | | | | | | | | | | |
Collapse
|
2
|
Huo S, Lei X, He D, Zhang H, Yang Z, Mu W, Fang K, Xue D, Li H, Li X, Jia N, Zhu H, Chen C, Yan K. Ferrous hemoglobin and hemoglobin-based oxygen carriers acting as a peroxidase can inhibit oxidative damage to endothelial cells caused by hydrogen peroxide. Artif Organs 2021; 45:1229-1239. [PMID: 34101875 DOI: 10.1111/aor.14009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 04/17/2021] [Accepted: 06/01/2021] [Indexed: 12/26/2022]
Abstract
Oxidative damage caused by the ferryl hemoglobin is one of the major clinical adverse reactions of hemoglobin-based oxygen carriers (HBOCs), while the production of reactive oxygen species in a pathological state can oxidize hemoglobin (HbFe2+ ) to ferryl Hb, which can then enter the pseudoperoxidase cycle, making hemoglobin highly toxic. In this study, we found that ferrous hemoglobin and polymerized porcine hemoglobin (one of the HBOCs) have the peroxidase activity different from the pseudoperoxidase activity of ferric hemoglobin. Ferrous hemoglobin can catalyze the reaction of tyrosine (Tyr) with hydrogen peroxide. In addition, the results also indicated that ferrous hemoglobin and pPolyHb have a strong inhibitory effect on the pseudoperoxidase activity of ferric hemoglobin. Therefore, hydrogen peroxide was consumed in a large amount, which greatly prevented hemoglobin from becoming oxidized and entering the pseudoperoxidase cycle, thus inhibiting ferryl Hb toxicity. We further cultured human umbilical vein endothelial cells and monitored cell morphology, viability, cell cycle, apoptosis, lactate dehydrogenase (LDH) release, and malondialdehydes (MDAs) formation when incubated with H2 O2 , Tyr, and HbFe2+ . HbFe2+ and pPolyHb reduced cell cycle arrest, apoptosis, LDH release, and MDA formation. These results showed that reducing oxidative damage induced by H2 O2 and converted hemoglobin from a molecule that is toxic to one that inhibits oxidative damage, suggesting a new strategy for development of a safer HBOCs.
Collapse
Affiliation(s)
- Shuangshuang Huo
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Xiaofeng Lei
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Dan He
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Hua Zhang
- Department of Oncology, Shaanxi Provincial People's Hospital, Xi'an, P.R. China
| | - Zhipeng Yang
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Wenhua Mu
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Ke Fang
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Dan Xue
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - He Li
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Xiaoyan Li
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Nan Jia
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Hongli Zhu
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Chao Chen
- College of Life Science, Northwest University, Xi'an, P.R. China
| | - Kunping Yan
- College of Life Science, Northwest University, Xi'an, P.R. China
| |
Collapse
|
3
|
Tsai AG, Cabrales P, Young MA, Winslow RM, Intaglietta M. Effect of oxygenated polyethylene glycol decorated hemoglobin on microvascular diameter and functional capillary density in the transgenic mouse model of sickle cell anemia. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2014; 43:10-7. [DOI: 10.3109/21691401.2014.936063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
4
|
Kutter APN, Mauch JY, Riond B, Martin-Jurado O, Spielmann N, Weiss M, Bettschart-Wolfensberger R. Evaluation of two devices for point-of-care testing of haemoglobin in neonatal pigs. Lab Anim 2011; 46:65-70. [PMID: 22087030 DOI: 10.1258/la.2011.011086] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
In veterinary medicine, point-of-care testing (POCT) techniques have become popular, since they provide immediate results and only small amounts of blood are needed. However, their accuracy is controversial. Pigs are often used for research purposes and accurate measurement of haemoglobin (Hb) is important during invasive procedures. The aim of this study was to evaluate two different Hb POCT devices in neonatal pigs. A prospective study with 57 pigs of 3-6 weeks of age, weighing 4.1-6.2 kg (median 5.1 kg) was performed. Fifty-seven blood samples were analysed for Hb using a conductivity-based and a photometrical POCT device and compared with a photometrical reference method. Statistical analysis was performed with Bland-Altman analysis, Spearman correlation and Passing-Bablok regression analysis. Hb values ranged from 32 to 108 g/L (median 80 g/L) using the reference method. The bias of the photometrical method (HemoCue(®)) to the reference method was -1 g/L, with limits of agreement (LOA) of -7 to 6 g/L. The conductivity-based method (i-STAT(®)) had a bias of -15 g/L with LOA from -24 to -6 g/L. There was a significant association between protein values and the bias of i-STAT versus CellDyn (r(2) = 0.27, P < 0.05) but not with the bias of HemoCue versus CellDyn (r(2) = 0.001, P = 0.79). The lower the protein values were, the lower the Hb values were measured by the i-STAT. The conductivity-based measurement of Hb constantly underestimated Hb values, whereas the photometrical method demonstrated a better accuracy and is therefore more reliable for on-site measurement of Hb in pigs.
Collapse
Affiliation(s)
- Annette P N Kutter
- Section of Anaesthesiology, Equine Department, Winterthurerstr. 260, 8057 Zurich, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
5
|
van der Linden P, Gazdzik TS, Jahoda D, Heylen RJ, Skowronski JC, Pellar D, Kofranek I, Górecki AZ, Fagrell B, Keipert PE, Hardiman YJ, Levy H. A Double-Blind, Randomized, Multicenter Study of MP4OX for Treatment of Perioperative Hypotension in Patients Undergoing Primary Hip Arthroplasty Under Spinal Anesthesia. Anesth Analg 2011; 112:759-73. [PMID: 21317165 DOI: 10.1213/ane.0b013e31820c7b5f] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
6
|
Haemoglobin-based oxygen carriers: research and reality towards an alternative to blood transfusions. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2010; 8 Suppl 3:s59-68. [PMID: 20606751 DOI: 10.2450/2010.010s] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
7
|
Young MA, Lohman J, Malavalli A, Vandegriff KD, Winslow RM. Hemospan Improves Outcome in a Model of Perioperative Hemodilution and Blood Loss in the Rat: Comparison With Hydroxyethyl Starch. J Cardiothorac Vasc Anesth 2009; 23:339-47. [DOI: 10.1053/j.jvca.2008.08.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2008] [Indexed: 11/11/2022]
|
8
|
Goertz O, Kirschner MH, Lilienfein H, Babilas P, Steinau HU, Andree C, Daigeler A, Stachon A, Homann H, Langer S. Effects of maleimide-polyethylene glycol-modified human hemoglobin (MP4) on tissue necrosis in SKH1-hr hairless mice. Eur J Med Res 2009; 14:123-9. [PMID: 19380283 PMCID: PMC3352061 DOI: 10.1186/2047-783x-14-3-123] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE Tissue hypoxia after blood loss, replantation and flap reperfusion remains a challenging task in surgery. Normovolemic hemodilution improves hemorheologic properties without increasing oxygen carrying capacity. Red blood cell transfusion is the current standard of treatment with its attendant risks. The aim of this study was to investigate the potential of the chemically modified hemoglobin, MP4, to reduce skin flap necrosis and its effect on selected blood markers and kidneys. MATERIALS AND METHODS Tissue ischemia was induced in the ear of hairless mice (n=26). Hemodilution was performed by replacing one third of blood volume with the similar amount of MP4, dextran, or blood. The extent of non-perfused tissue was assessed by intravital fluorescent microscopy. RESULTS Of all groups, MP4 showed the smallest area of no perfusion (in percentage of the ear +/- SEM: 16.3% +/- 2.4), the control group the largest (22.4% +/- 3.5). Leukocytes showed a significant increase in the MP4 and dextran group (from 8.7 to 13.6 respectively 15.4*109/l). On histology no changes of the kidneys could be observed. CONCLUSION MP4 causes an increase of leukocytes, improves the oxygen supply of the tissue and shows no evidence of renal impairment.
Collapse
Affiliation(s)
- Ole Goertz
- Department of Plastic and Hand Surgery, Burn Center, Ruhr-University Bochum, Bochum, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Vandegriff KD, Winslow RM. Hemospan: Design Principles for a New Class of Oxygen Therapeutic. Artif Organs 2009; 33:133-8. [DOI: 10.1111/j.1525-1594.2008.00697.x] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Vandegriff KD, Malavalli A, Mkrtchyan GM, Spann SN, Baker DA, Winslow RM. Sites of Modification of Hemospan, a Poly(ethylene glycol)-Modified Human Hemoglobin for Use As an Oxygen Therapeutic. Bioconjug Chem 2008; 19:2163-70. [DOI: 10.1021/bc8002666] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Kim D. Vandegriff
- Sangart Inc., 6175 Lusk Boulevard, San Diego, California, 92121, and Department of Bioengineering, University of California, San Diego, La Jolla, California 92093
| | - Ashok Malavalli
- Sangart Inc., 6175 Lusk Boulevard, San Diego, California, 92121, and Department of Bioengineering, University of California, San Diego, La Jolla, California 92093
| | - Gnel M. Mkrtchyan
- Sangart Inc., 6175 Lusk Boulevard, San Diego, California, 92121, and Department of Bioengineering, University of California, San Diego, La Jolla, California 92093
| | - Stephanie N. Spann
- Sangart Inc., 6175 Lusk Boulevard, San Diego, California, 92121, and Department of Bioengineering, University of California, San Diego, La Jolla, California 92093
| | - Dale A. Baker
- Sangart Inc., 6175 Lusk Boulevard, San Diego, California, 92121, and Department of Bioengineering, University of California, San Diego, La Jolla, California 92093
| | - Robert M. Winslow
- Sangart Inc., 6175 Lusk Boulevard, San Diego, California, 92121, and Department of Bioengineering, University of California, San Diego, La Jolla, California 92093
| |
Collapse
|
11
|
Olofsson C, Nygårds EB, Ponzer S, Fagrell B, Przybelski R, Keipert PE, Winslow N, Winslow RM. A randomized, single-blind, increasing dose safety trial of an oxygen-carrying plasma expander (Hemospan) administered to orthopaedic surgery patients with spinal anaesthesia. Transfus Med 2008; 18:28-39. [PMID: 18279190 DOI: 10.1111/j.1365-3148.2007.00811.x] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The objective of this study was to further explore the safety of Hemospan (Sangart Inc., San Diego, CA, USA), an oxygen-carrying plasma expander. The aim of this study was to determine if Hemospan is well tolerated in orthopaedic surgery patients with spinal anaesthesia in doses up to 1 L. Hemospan was previously found to be well tolerated in normal volunteers and orthopaedic surgery patients with spinal anaesthesia in doses up to 500 mL. Five cohorts of six orthopaedic surgery patients, American Society of Anesthesiologists (ASA) I and II, were studied. In each cohort, four patients received Hemospan in doses ranging from 200 to 1000 mL, and two received Ringer's lactate immediately prior to induction of spinal anaesthesia. There were no serious adverse events (SAEs). Iohexol clearance measured before and 24 h after dosing was unaffected. There were 14 adverse events (AEs) in the 10 control patients (1.4 per patient) and 30 in the 20 patients receiving Hemospan (1.5 per patient). One patient in the group receiving 200 mL Hemospan had elevated mean arterial pressure after dosing, but there were no elevations in any of the other patients. The peak plasma Hemospan concentration in the 1000 mL group was 1.3 g dL(-1), with a dose-dependent clearance (T(1/2)) ranging from 14.1 to 23.0 h. Plasma methaemoglobin levels were independent of dose, reaching a maximum at 40 h after dosing and never exceeded 0.125 g dL(-1). Troponin T was transiently elevated in two patients receiving Hemospan without symptoms or electrocardiographic abnormalities or elevation of myocardial creatinine kinase isoenzyme. Hemospan was well tolerated in this group of patients at doses up to 1000 mL.
Collapse
Affiliation(s)
- C Olofsson
- Department of Anaesthesiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Cell-free oxygen carriers: scientific foundations, clinical development, and new directions. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2008; 1784:1382-6. [PMID: 18555029 DOI: 10.1016/j.bbapap.2008.04.032] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2008] [Revised: 04/16/2008] [Accepted: 04/22/2008] [Indexed: 11/23/2022]
Abstract
The most significant hurdle to the development of a safe and effective hemoglobin-based oxygen carrier ("blood substitute") is generally thought to be its propensity to cause vasoconstriction in the microcirculation and hypertension. Two theories for this effect are currently being studied: in one, scavenging NO by hemoglobin reduces vasorelaxation; in the other, cell-free hemoglobin oversupplies O2 (a known vasoconstrictor) to vascular walls by facilitated diffusion. While both mechanisms might lead to reduction of local NO concentration, the important distinction between the two is that if the NO scavenging theory is correct, it greatly diminishes the prospects to develop any solution based on free hemoglobin. However, if the O2-oversupply theory is correct, modifications to the hemoglobin molecule can be envisioned that can prevent oversupply and reduce toxicity. This review summarizes the development of Hemospan, a novel modification of human hemoglobin whose design is based on the O2-oversupply theory. Because of its low P50 and increased molecular size, the release of O2 in resistance vessels (arterioles) by Hemospan is restricted, and vasoconstriction is greatly reduced.
Collapse
|
13
|
Haemoglobin, oxygen carriers and perioperative organ perfusion. Best Pract Res Clin Anaesthesiol 2008; 22:63-80. [DOI: 10.1016/j.bpa.2007.10.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
14
|
Svergun DI, Ekström F, Vandegriff KD, Malavalli A, Baker DA, Nilsson C, Winslow RM. Solution structure of poly(ethylene) glycol-conjugated hemoglobin revealed by small-angle X-ray scattering: implications for a new oxygen therapeutic. Biophys J 2008; 94:173-81. [PMID: 17827244 PMCID: PMC2134876 DOI: 10.1529/biophysj.107.114314] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2007] [Accepted: 08/07/2007] [Indexed: 11/18/2022] Open
Abstract
Developing protein therapeutics has posed challenges due to short circulating times and toxicities. Recent advances using poly(ethylene) glycol (PEG) conjugation have improved their performance. A PEG-conjugated hemoglobin (Hb), Hemospan, is in clinical trials as an oxygen therapeutic. Solutions of PEG-hemoglobin with two (P5K2) or six to seven strands of 5-kD PEG (P5K6) were studied by small-angle x-ray scattering. PEGylation elongates the dimensions (Hb < P5K2 < P5K6) and leaves the tertiary hemoglobin structure unchanged but compacts its quaternary structure. The major part of the PEG chains visualized by ab initio reconstruction protrudes away from hemoglobin, whereas the rest interacts with the protein. PEGylation introduces intermolecular repulsion, increasing with conjugated PEG amount. These results demonstrate how PEG surface shielding and intermolecular repulsion may prolong intravascular retention and lack of reactivity of PEG-Hb, possibly by inhibiting binding to the macrophage CD163 hemoglobin-scavenger receptor. The proposed methodology for assessment of low-resolution structures and interactions is a powerful means for rational design of PEGylated therapeutic agents.
Collapse
Affiliation(s)
- Dmitri I Svergun
- European Molecular Biology Laboratory, Hamburg Outstation, Hamburg, Germany
| | | | | | | | | | | | | |
Collapse
|
15
|
Young MA, Riddez L, Kjellström BT, Winslow RM. Effect of Maleimide-Polyethylene Glycol Hemoglobin (MP4) on Hemodynamics and Acid-Base Status After Uncontrolled Hemorrhage in Anesthetized Swine: Comparison With Crystalloid and Blood. ACTA ACUST UNITED AC 2007; 63:1234-44. [DOI: 10.1097/ta.0b013e31815bd7b0] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
16
|
VANDEGRIFF KIMD, YOUNG MARKA, KEIPERT PETERE, WINSLOW ROBERTM. The safety profile of Hemospan®: a new oxygen therapeutic designed using maleimide poly(ethylene) glycol conjugation to human hemoglobin. ACTA ACUST UNITED AC 2007. [DOI: 10.1111/j.1778-428x.2007.00083.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
17
|
Driessen B, Zarucco L, Gunther RA, Burns PM, Lamb SV, Vincent SE, Boston RA, Jahr JS, Cheung ATW. Effects of low-volume hemoglobin glutamer-200 versus normal saline and arginine vasopressin resuscitation on systemic and skeletal muscle blood flow and oxygenation in a canine hemorrhagic shock model. Crit Care Med 2007; 35:2101-9. [PMID: 17581486 DOI: 10.1097/01.ccm.0000277040.31978.3d] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To test the hypothesis that low-volume resuscitation with hemoglobin glutamer-200 improves hemodynamic function and tissue oxygenation, whereas arginine vasopressin resuscitation improves blood pressures more than low-volume saline or hemoglobin glutamer infusion but compromises systemic and muscle blood flow and oxygenation. DESIGN Randomized laboratory investigation. SETTING University research facility. SUBJECTS Nineteen dogs. INTERVENTIONS Dogs were instrumented to determine heart rate; arterial, central venous, pulmonary arterial, and pulmonary arterial occlusion pressures; cardiac output; and quadriceps muscle blood flow and oxygen tension (PMo2). Total and plasma hemoglobin, oxygen content, lactate, pH, standard base excess, and arginine vasopressin levels were determined, and systemic oxygen delivery (Do2I) and extraction ratio were calculated. Measurements were made before and 30 mins following hemorrhage. Dogs were resuscitated over 60 mins with saline (8.5 mL/kg), arginine vasopressin (0.4 IU/kg bolus plus 0.08 IU x kg x min), or 1:1 diluted hemoglobin glutamer-200. Recordings were then repeated. Subsequently, animals received 30 mL/kg shed blood (60 mL x kg x hr), and recordings were repeated immediately and 1 hr later. MEASUREMENTS AND MAIN RESULTS Hemorrhage ( approximately 52 mL/kg) caused characteristic changes in hemodynamic, hematologic, systemic PMo2, and acid-base variables. Saline resuscitation increased both Do2I and muscle perfusion by 42% and 51%, while arginine vasopressin treatment reduced heart rate by 31% and increased mean arterial pressure by 22% but not cardiac output, Do2I, or muscle blood flow, resulting in a further decrease of PMo2 by 68% and worse metabolic acidosis. Hemoglobin glutamer-200 infusion caused systemic and pulmonary vasoconstriction, however, without deterioration of cardiac output, Do2I, muscle blood flow, or PMo2 despite lack of oxygen content increase. Blood transfusion restored most variables. CONCLUSIONS Low-volume crystalloid or hemoglobin glutamer-200 resuscitation posthemorrhage may improve (but not restore) macro- and microvascular functions and tissue oxygenation, while arginine vasopressin infusion may only improve blood pressures and result in lower overall systemic perfusion compared with low-volume saline or hemoglobin glutamer-200 treatment and worsening of anaerobic conditions in skeletal muscle.
Collapse
Affiliation(s)
- Bernd Driessen
- University of Pennsylvania, School of Veterinary Medicine, Department of Clinical Studies, Section of Critical Care, New Bolton Center, Kennett Square, PA, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Young MA, Malavalli A, Winslow N, Vandegriff KD, Winslow RM. Toxicity and hemodynamic effects after single dose administration of MalPEG-hemoglobin (MP4) in rhesus monkeys. Transl Res 2007; 149:333-42. [PMID: 17543852 DOI: 10.1016/j.trsl.2006.09.007] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2006] [Revised: 09/25/2006] [Accepted: 09/27/2006] [Indexed: 01/22/2023]
Abstract
Maleimide-polyethylene glycol-modified (MalPEG) hemoglobin, 4.3 g/dL (MP4; Hemospan), is a hemoglobin-based oxygen carrier consisting of human hemoglobin (Hb) modified with maleimide polyethylene glycol. This study evaluates the potential toxicity and hemodynamic actions of a single dose of MP4 administered by exchange transfusion to rhesus monkeys. Monkeys were administered MP4 (21 mL/kg, or approximately 30% of estimated blood volume) or an equivalent volume of lactated Ringer's solution (LR). In the toxicity study, blood samples were obtained predose and 3, 7, and 13 days after dosing for clinical chemistry and hematology. Animals were euthanized for complete necropsy and histopathology on day 3 or day 13. A separate group of animals was used for evaluation of arterial pressure, core temperature, and electrocardiogram, by telemetry, for 7 days after dosing with MP4. The results demonstrate no significant toxicity, with only modest, transient elevation of aspartate aminotransferase (AST), alanine aminotransferase (ALT), and lactate dehydrogenase (LDH) on day 3. Mild anemia caused by hemodilution was observed at each time point in both groups, but to a slightly greater degree in the MP4-treated animals. Histologic observations included foamy or vacuolated macrophages in the spleen and marrow of the sternum, rib, and femur, representing the accumulation of test article or a metabolite. In the telemetry study, no changes occurred in arterial pressure, heart rate, or electrocardiogram attributable to administration of MP4 at any time for 7 days after administration. These results demonstrate that MP4 is safe and is without hemodynamic effects when administered as an exchange transfusion of 30% of estimated blood volume.
Collapse
|
19
|
Abstract
Oxygen-carrying plasma expanders (blood substitutes) have been sought for over a century. Development of current products is a result of evolution in the understanding of proteins in general, of hemoglobin in particular, and of how cell-free hemoglobin interacts with the control of local blood flow to ensure adequate tissue oxygenation. Hemoglobin-based products are considered in four "generations" corresponding to major improvements. First-generation products consisted of hemoglobin, freed of red cell membranes (stroma-free hemoglobin [SFH]), which was renal toxic and vasoactive. Second-generation products were polymerized with aldehyde reagents to reduce or eliminate the renal toxicity, but the products were heterogeneous and still vasoactive. Third-generation products employed more specific intramolecular crosslinking to eliminate polymerization and promote homogeneity, but they also remained vasoactive. Fourth-generation products are based on a new understanding of the way in which microvascular blood flow is controlled and the influence of O(2) delivery to vascular walls. After more than a century of research, one of these new solutions should find use as an alternative to red cells for transfusion in certain clinical settings.
Collapse
Affiliation(s)
- Robert M Winslow
- Sangart, Inc, and Department of Bioengineering, University of California, San Diego, CA 92121, USA.
| |
Collapse
|
20
|
Driessen B, Jahr JS, Lurie F, Gunther RA. Effects of isovolemic resuscitation with hemoglobin-based oxygen carrier Hemoglobin glutamer-200 (bovine) on systemic and mesenteric perfusion and oxygenation in a canine model of hemorrhagic shock: a comparison with 6% hetastarch solution and shed blood. Vet Anaesth Analg 2006; 33:368-80. [PMID: 17083609 DOI: 10.1111/j.1467-2995.2005.00280.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To study Hemoglobin glutamer-200 bovine (Hb-200), 6% hetastarch (HES) and shed whole blood (WB) resuscitation in canine hemorrhagic shock. STUDY DESIGN Prospective laboratory investigation. Animals Twelve adult dogs [29 +/- 1 kg (mean +/- SD)]. METHODS Anesthetized dogs were instrumented for recording systemic and mesenteric hemodynamic parameters and withdrawal of arterial, mixed and mesenteric venous blood, in which hematological, oxygenation, blood gas and acid-bases variables were determined. Recordings were made before [baseline (BL)], after 1 hour of hypovolemia and immediately and 3 hours post-resuscitation with 30 mL kg(-1) of either Hb-200, HES, or WB. RESULTS Blood withdrawal (average 34 +/- 2 mL kg(-1)) caused significant hemodynamic changes, metabolic acidosis and hyperlactatemia characteristic for hemorrhagic shock. Only WB transfusion restored all variables. Hemoglobin glutamer-200 bovine infusion returned most hemodynamic parameters including cardiac output and mesenteric arterial blood flow to BL but increased mean arterial pressure above BL (p < 0.05). However, Hb-200 failed to restore total Hb and arterial oxygen content (CaO2), leaving systemic (DO2I) and mesenteric O2 delivery (DO2Im) below BL (p < 0.05). Nevertheless, acid-base variables recovered completely after Hb-200 resuscitation, and met-hemoglobin (Met-Hb) levels increased (p < 0.05). Hetastarch resuscitation returned hemodynamic variables to or above BL but further decreased total Hb and CaO2, preventing recovery of sDO2I and mDO2I (p < 0.05). Thus, systemic and mesenteric O2 extraction stayed above BL (p < 0.05) while acid-base variables recovered to BL, although slower than in Hb-200 and WB groups (p < 0.05). CONCLUSIONS AND CLINICAL RELEVANCE Resuscitation with Hb-200 seemed to resolve metabolic acidosis and lactatemia more rapidly than HES, but not WB; yet it is not superior to HES in improving DO2I and DO2Im. The hyperoncotic property of solutions like Hb-200 that results in rapid volume expansion with more homogenous microvascular perfusion and the ability to facilitate diffusive O2 transfer accelerating metabolic recovery may be the key mechanisms underlying their beneficial effects as resuscitants.
Collapse
Affiliation(s)
- B Driessen
- Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, PA 19348, USA.
| | | | | | | |
Collapse
|
21
|
|
22
|
Hare GMT, Harrington A, Liu E, Wang JL, Baker AJ, Mazer CD. Effect of oxygen affinity and molecular weight of HBOCs on cerebral oxygenation and blood pressure in rats. Can J Anaesth 2006; 53:1030-8. [PMID: 16987859 DOI: 10.1007/bf03022533] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This study assessed the effect of oxygen affinity and molecular weight (MW) of o-raffinose cross-linked hemoglobin based oxygen carriers (HBOCs) on cerebral oxygen delivery and mean arterial blood pressure (MAP) following hemorrhage and resuscitation in rats. METHODS Isoflurane anesthetized rats (n = 6-7 per group) underwent 30% hemorrhage and resuscitation with an equivalent volume of one of three different HBOCs: 1) High P50 Poly o-raffinose hemoglobin (Poly OR-Hb, P50 = 70 mmHg); 2) High P50 > 128 Poly OR-Hb (MW > 128 kDa, P50 = 70 mmHg) and 3) Low P50 > 128 Poly OR-Hb (MW >128 kDa, P50 = 11 mmHg). Hippocampal cerebral tissue oxygen tension, regional cerebral blood flow (rCBF), MAP, total hemoglobin concentration and arterial blood gases were measured. Data analysis by two-way ANOVA and post hoc Tukey tests determined significance (P < 0.05, mean +/- SD). RESULTS Hippocampal tissue oxygen tension increased in all HBOC groups following resuscitation. The rCBF remained unchanged after HBOC resuscitation in all groups. Following resuscitation, the peak MAP was higher in the High P50 Poly OR-Hb group (152 +/- 13 mmHg) when compared to either the Low or High P50 large MW, (> 128 kDa) HBOC group (119 +/- 15 mmHg or 127 +/- 18 respectively, P < 0.05 for both). CONCLUSIONS O-raffinose polymerized HBOC, with or without lower MW components, maintained cerebral tissue oxygen delivery following hemorrhage and resuscitation in rats. The higher MW HBOCs showed a decrease in peak MAP, which did not alter oxygen delivery. No significant effect of oxygen affinity on cerebral tissue oxygen tension or blood flow was observed.
Collapse
|
23
|
|
24
|
Intaglietta M, Cabrales P, Tsai AG. MICROVASCULAR PERSPECTIVE OF OXYGEN-CARRYING AND -NONCARRYING BLOOD SUBSTITUTES. Annu Rev Biomed Eng 2006; 8:289-321. [PMID: 16834558 DOI: 10.1146/annurev.bioeng.8.061505.095713] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The development of an alternative to natural blood has evolved from the initial goal of replicating blood properties to the current objective of formulating a fluid that can be used to replace blood while preserving microvascular function and delivering oxygen. The properties of this fluid are counterintuitive and different from blood because it has high viscosity, oxygen affinity, and a low oxygen carrier concentration when compared with blood. The optimal oxygen carrier devised presently is poly-ethylene-conjugated human hemoglobin, a material demonstrated to be vasoinactive and void of the toxicities present in previous hemoglobin formulations. A feature of this material is that it is effective in small quantities, and therefore amplifies the equivalent supply of blood derived from blood donations.
Collapse
Affiliation(s)
- Marcos Intaglietta
- Department of Bioengineering, University of California, San Diego, La Jolla, California 92093-0412, USA.
| | | | | |
Collapse
|
25
|
Driessen B, Brainard B. Fluid therapy for the traumatized patient. J Vet Emerg Crit Care (San Antonio) 2006. [DOI: 10.1111/j.1476-4431.2005.00184.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
26
|
Habler O, Pape A, Meier J, Zwissler B. [Artificial oxygen carriers as an alternative to red blood cell transfusion]. Anaesthesist 2005; 54:741-54. [PMID: 16021390 DOI: 10.1007/s00101-005-0893-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The expected cost-explosion in transfusion medicine (increasing imbalance between donors and recipients, treatment of transfusion-associated complications) increases the socio-economic significance of the development of safe and effective synthetic oxygen carriers as an alternative to the transfusion of allogeneic red blood cells. Currently two types of artificial oxygen carriers have been tested for safety and efficacy in cases of severe anemia otherwise requiring transfusion. Solutions based on human or bovine hemoglobin (HBOC) possess vasoconstrictor properties in addition to their oxygen transport capacity. The impact of vasoconstriction on tissue perfusion and organ function is however not yet fully understood. Nevertheless, in 2001 the bovine HBOC Hemopure was approved in South Africa for treatment of acutely anemic surgical patients. The purely synthetic perfluorocarbon (PFC) emulsions increase the physically dissolved portion of arterial oxygen content. Due to their particulate nature (emulsion droplets) PFCs may only be infused in low doses to avoid overload and malfunction of phagocytic cells of the reticulo-endothelial system. As part of a multimodal blood conservation program (including normovolemic hemodilution and hyperoxia) the low-dose administration of Oxygent effectively increases intraoperative anemia tolerance. Although reduction of perioperative allogeneic blood transfusion has already been demonstrated for HBOC and PFC, the global clinical establishment of artificial oxygen carriers is not to be expected in the near future.
Collapse
Affiliation(s)
- O Habler
- Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Johann Wolfgang Goethe-Universität, Frankfurt a. M.
| | | | | | | |
Collapse
|
27
|
Young MA, Riddez L, Kjellström BT, Bursell J, Winslow F, Lohman J, Winslow RM. MalPEG-hemoglobin (MP4) improves hemodynamics, acid-base status, and survival after uncontrolled hemorrhage in anesthetized swine. Crit Care Med 2005; 33:1794-804. [PMID: 16096458 DOI: 10.1097/01.ccm.0000172648.55309.13] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES MalPEG-hemoglobin, 4 g/dL (MP4), is a hemoglobin-based oxygen carrier with a low hemoglobin concentration, low P50 (oxygen half-saturation pressure of hemoglobin), high colloid osmotic pressure, and high viscosity. This study evaluated resuscitation with MP4 in anesthetized swine hemorrhaged 250 mL by controlled withdrawal, followed by a 5-mm tear in the abdominal aorta. DESIGN Randomized, unblinded. SETTING Academic animal laboratory. SUBJECTS Anesthetized male and female Swedish Landrace pigs. INTERVENTIONS Four groups of pigs (n = 7 each) were randomized after hemorrhage by aortic tear to receive 250 mL of MP4, Ringer's acetate, 10% pentastarch, or 4 g/dL of stroma-free hemoglobin, followed by aortic repair and transfusion of 250 mL of autologous blood. End points were 20-hr survival, hemodynamic variables, and acid-base status. MEASUREMENTS AND MAIN RESULTS Measurements included continuous aortic, pulmonary arterial, and central venous pressures, cardiac output by thermodilution, arterial and venous blood gases; electrolytes; lactate; base excess; oxygen delivery, consumption, and extraction ratio; hematocrit; hemoglobin; and urine output. Body weight (24-27 kg) and hemorrhage volume (26-33 mL/kg) were similar in the four groups. The nadir of mean arterial pressure (22-28 mm Hg) and the increase in lactic acid (5-8 mEq/L) after hemorrhage were similar in all groups, indicating equivalent shock in the four groups. Survival was greatest in the MP4-treated animals (six of seven) compared with Ringer's acetate (two of seven), 10% pentastarch (one of seven), and stroma-free hemoglobin (two of seven) and was accompanied by an improved recovery of arterial pressure, cardiac output, and lactate. Total hemoglobin concentration was equivalent in all groups. Arterial pressure did not increase above baseline values, and systemic vascular resistance was unchanged following administration of MP4, indicating the lack of peripheral vasoconstriction. Mortality in Ringer's acetate, stroma-free hemoglobin, and 10% pentastarch treated animals was associated with deteriorating acid-base status, low urine output, and hyperkalemia. CONCLUSION These data demonstrate that restoration of oxygen delivery with a small volume of MP4 yields significant recovery from hemorrhage without systemic vasoconstriction.
Collapse
|
28
|
Abstract
This article describes currently evaluated artificial O2 carriers, summarizes their efficacy, and discusses their side effects, based on and restricted to published data. For compounds in phase III testing, approximately 500 to 1000 patients have been dosed, and similar numbers of control patients have been investigated. For compounds in phase I or II testing, the number of patients dosed is significantly less. Unfortunately, there is a significant amount of nonpublished data, which renders the overall assessment difficult, and the direct comparison among different types of artificial O2 carriers is significantly limited by the virtual nonexistence of studies that directly compare different products.
Collapse
Affiliation(s)
- Caroline Thyes
- Department of Anesthesiology, University Hospital Lausanne, (CHUV) CH-1011 Lausanne, Switzerland
| | | |
Collapse
|
29
|
Cabrales P, Tsai AG, Winslow RM, Intaglietta M. Effects of extreme hemodilution with hemoglobin-based O2 carriers on microvascular pressure. Am J Physiol Heart Circ Physiol 2005; 288:H2146-53. [PMID: 15637119 DOI: 10.1152/ajpheart.00749.2004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A surface-modified polyethylene glycol-conjugated human hemoglobin (MP4) and alpha alpha-cross-linked human hemoglobin (alpha alpha Hb) were used to restore oxygen carrying capacity in conditions of extreme hemodilution (hematocrit 11%) in the hamster window model preparation. Changes in microvascular function were analyzed in terms of effects on capillary pressure and functional capillary density (FCD). MP4, at 1.0 +/- 0.2 g/dl blood concentration, significantly lowered mean arterial pressure (MAP) below baseline (99.6 +/- 7.6 mmHg) to 82.4 +/- 6.9 mmHg (P < 0.05) and decreased of FCD to 70 +/- 9%. alpha alpha Hb caused a greater recovery in MAP to 94.4 +/- 6.2 mmHg and lowered FCD to 62 +/- 8%. However, differences between alpha alpha Hb and MP4 in FCD were not statistically significant. Capillary pressures were in the ranges of 17-21 mmHg for MP4 and 15-19 mmHg for alpha alpha Hb, with both significantly lower than baseline (P < 0.05). Pressure in 80-microm-diameter arterioles was significantly increased with alpha alpha Hb relative to MP4 (P < 0.05). These results were compared with previous findings on the relation between capillary pressure and FCD; they supported the concept of a relationship between FCD and capillary pressure. Measurement of changes in arteriolar diameter, microvascular blood flow, and FCD show that there was no statistical difference between using alpha alpha Hb and MP4 in extreme hemodilution. Microvascular resistance in arterioles with a diameter range of 70-80 microm showed an increase relative to control with alpha alpha Hb, whereas MP4 caused a decrease.
Collapse
Affiliation(s)
- Pedro Cabrales
- Department of Bioengineering, University of California-San Diego, La Jolla, CA 92093-0412, USA.
| | | | | | | |
Collapse
|
30
|
|