1
|
Cai R, Liu Y, Wang X, Wei H, Wang J, Cao Y, Lei J, Li D. Influences of standardized clinical probing on peri-implant soft tissue seal in a situation of peri-implant mucositis: A histomorphometric study in dogs. J Periodontol 2024; 95:233-243. [PMID: 37515595 DOI: 10.1002/jper.23-0167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 07/20/2023] [Accepted: 07/24/2023] [Indexed: 07/31/2023]
Abstract
BACKGROUND Clinical probing is commonly recommended to evaluate peri-implant conditions. In a situation of peri-implant mucositis or peri-implantitis, the peri-implant seal healing from the disruption of soft tissue caused by probing has not yet been studied. This study aimed to investigate soft tissue healing after standardized clinical probing around osseointegrated implants with peri-implant mucositis in a dog model. METHODS Three transmucosal implants in each hemi-mandible of six dogs randomly assigned to the peri-implant healthy group or peri-implant mucositis group were probed randomly in the mesial or distal site as probing groups (PH or PM), the cross-sectional opposite sites as unprobed control groups. Histomorphometric measurements of implant shoulder (IS)-most coronal level of alveolar bone contact to the implant surface (BCI), apical termination of the junctional epithelium (aJE)-BCI, mucosal margin (MM)-BCI, and MM-aJE were performed at 1 day, 1 week, and 2 weeks after probing. Apoptosis, proliferation, proinflammatory cytokines, and matrix metalloproteinases (MMPs) of peri-implant soft tissue were estimated by immunofluorescent analysis. RESULTS In the PM group, apical migration of junctional epithelium was revealed by significantly decreased aJE-BCI from 1 day to 2 weeks in comparison to unprobed sites (p < 0.05), while no significant differences were found in the PH group. Immunofluorescent analysis showed higher levels of interleukin-1β (IL-1β), IL-6, tumor necrosis factor-α (TNF-α), MMP-1, and MMP-8, together with exaggerated apoptosis and proliferation of peri-implant soft tissue in the PM group. CONCLUSION Within the limitations, standardized clinical probing might lead to apical migration of the junctional epithelium in a situation of peri-implant mucositis.
Collapse
Affiliation(s)
- Rong Cai
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Yi Liu
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Xinge Wang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Hongbo Wei
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Jin Wang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Yanze Cao
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Jiaqi Lei
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Dehua Li
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| |
Collapse
|
2
|
Atieh MA, Shah M, Ameen M, Tawse-Smith A, Alsabeeha NHM. Influence of implant restorative emergence angle and contour on peri-implant marginal bone loss: A systematic review and meta-analysis. Clin Implant Dent Relat Res 2023; 25:840-852. [PMID: 37183357 DOI: 10.1111/cid.13214] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 04/05/2023] [Accepted: 04/26/2023] [Indexed: 05/16/2023]
Abstract
BACKGROUND Implant restorative emergence angle and profile may have a negative impact on peri-implant marginal bone level and may increase the risk of developing peri-implantitis. However, the role of these prosthetic features on peri-implant health is still unclear. The aim of this systematic review and meta-analyses was to evaluate the long-term outcomes of implant restorations with an emergence angle of >30° in comparison to those with ≤30° in terms of changes in peri-implant marginal bone level, periodontal parameters, and prevalence rate of peri-implantitis. METHODS Electronic databases were searched to identify observational studies that compared implant restorations with an emergence angle of >30° to those with ≤30°. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool. RESULTS Four studies with 912 dental implants in 397 participants were included in the present review. Of these, 455 implants had restorations with an emergence angle of >30°, while the remaining implants had restorative emergence angle of ≤30°. The follow-up time varied between 3.8 and 10.9 years. Implant restorations with an emergence angle of ≤30° were associated with less changes in peri-implant marginal bone level compared to those with emergence angle of >30°. The difference, however, was not statistically significant (mean difference 0.80; 95% confidence interval (CI) -0.13 to 1.72; p = 0.09). In platform-matched implants, the difference between the two groups was statistically significant in favor of implant restorations with emergence angle of ≤30°. In terms of emergence profile, implant restorations with convex profile had significantly higher rate of peri-implantitis (57.8%) compared to implant restorations with concave or straight profile (21.3%) (risk ratio 2.32; 95% CI 1.12-4.82; p = 0.02). CONCLUSIONS Within the limitation of this review, implant restorations with an emergence angles of >30° or ≤30° seem to have no significant influence on peri-implant marginal bone level. Platform-matched implants with an emergence angle of ≤30° may have positive effects on the peri-implant marginal bone level changes, but the evidence support is of low to moderate certainty.
Collapse
Affiliation(s)
- Momen A Atieh
- Mohammed Bin Rashid University of Medicine and Health Sciences, Hamdan Bin Mohammed College of Dental Medicine, Dubai Healthcare City, Dubai, United Arab Emirates
- Faculty of Dentistry, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand
| | - Maanas Shah
- Mohammed Bin Rashid University of Medicine and Health Sciences, Hamdan Bin Mohammed College of Dental Medicine, Dubai Healthcare City, Dubai, United Arab Emirates
| | - Mohammed Ameen
- Mohammed Bin Rashid University of Medicine and Health Sciences, Hamdan Bin Mohammed College of Dental Medicine, Dubai Healthcare City, Dubai, United Arab Emirates
| | - Andrew Tawse-Smith
- Faculty of Dentistry, Sir John Walsh Research Institute, University of Otago, Dunedin, New Zealand
| | - Nabeel H M Alsabeeha
- Department of Dental Services, Emirates Health Services, Dubai, United Arab Emirates
| |
Collapse
|
3
|
Aljalloud AA, Dayoub S, Tolibah YA. Prevalence and risk factors of peri-implant diseases at patient-level: A cross-sectional study in Syria. Clin Exp Dent Res 2023; 9:783-790. [PMID: 37767767 PMCID: PMC10582216 DOI: 10.1002/cre2.792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 09/18/2023] [Accepted: 09/19/2023] [Indexed: 09/29/2023] Open
Abstract
OBJECTIVES This research aims to assess the prevalence of peri-implant diseases and to analyze variables of the probable risk at the patient level associated with the occurrence of peri-implant diseases in Syrian patients. MATERIALS AND METHODS A cross-sectional study has been carried out on 142 patients with 380 dental implants placed between 2015 and 2021. Patients were invited by phone to return to Damascus University's Periodontology Department for clinical and radiological examination. A descriptive statistical analysis was implemented for the prevalence of peri-implant diseases at the level of the patients. Also, the peri-implant diseases' factors of risk were determined by the multivariate analytical model. RESULTS The prevalence rate of peri-implant mucositis and peri-implantitis in patients was 58.5% and 25.4%, respectively. Peri-implant disease is associated with multivariate risk indices, gender female (peri-implant mucositis [OR = 0.269; 95% CI: 0.131-0.552] and peri-implantitis [OR = 0.561; 95% CI: 0.561-0.216]), diabetes (peri-implant mucositis [OR = 3.4; 95% CI: 1.73-12.73]), periodontitis (peri-implant mucositis [OR = 2.409; 95% CI: 1.760-2.613], peri-implantitis [OR = 10.445; 95% CI: 4.097-26.629]). CONCLUSIONS Peri-implant diseases are common in the Syrian community. Several patient-level variables (gender female, diabetes, and periodontitis) are associated with peri-implant disease.
Collapse
Affiliation(s)
| | - Suleiman Dayoub
- Department of PeriodontologyFaculty of Dentistry, Damascus UniversityDamascusSyria
| | | |
Collapse
|
4
|
Boldeanu LC, Boariu M, Rusu D, Vaduva A, Roman A, Surlin P, Martu I, Dragoi R, Popa-Wagner A, Stratul SI. Histomorphometrical and CBCT Evaluation of Tissue Loss Progression Induced by Consecutive, Alternate Ligatures in Experimental Peri-Implantitis in a Dog Model: A Pilot Study. J Clin Med 2022; 11:jcm11206188. [PMID: 36294510 PMCID: PMC9605274 DOI: 10.3390/jcm11206188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 09/29/2022] [Accepted: 10/17/2022] [Indexed: 11/16/2022] Open
Abstract
Objectives: Soft and hard tissue breakdown was histologically and radiologically assessed around implants with alternate, consecutively placed ligatures on the same edentulous dog hemimandible. The influence of ligatured implants (LI) on adjacent non-ligatured implants (NLI, as a possible naturally induced peri-implantitis) was also evaluated. Material and Methods: Three months after tooth extraction, five dental implants were placed in the dog hemimandible. Two months after abutment placement, ligatures were placed subsequently two months apart on alternate implants, while both intermediate implants were left without ligatures. Ligatures were kept in place during the entire experiment, and no plaque control measures were taken. Eleven months post-implantation, the animal was sacrificed. Undecalcified ground sections were cut, stained with Masson Goldner and MOVAT Pentachrome and evaluated by light microscopy. Soft and hard tissue loss was assessed using histomorphometric and CBCT parameters. Results: All NLI presented deep false peri-implant pockets on the oral aspect and pronounced vertical bone resorption on the buccal aspect. After 2, 4 and 6 months, during the breakdown period, more than 30% of the bone was lost in LI in all directions, while, despite immediate vicinity, NLI displayed less destruction. Intense inflammation, typical for induced peri-implantitis, was present, with similar intensity in LI as NLI, but in different parts of the lesions. Morphometry confirmed intense soft tissue inflammation, more bone resorption and higher amounts of infiltrated connective tissue in LI when compared with NLI. Conclusion: Within the limits of the present pilot study, the adequacy of the experimental dog model based on ligature-induced peri-implantitis was able to be successfully challenged by non-ligature models of spontaneously occurring peri-implant inflammation, while meeting the requirements for experimental designs with a very small numbers of animals. The influence of implants with severe peri-implantitis on adjacent implants resulted in less than expected tissue loss in the latter accession numbers.
Collapse
Affiliation(s)
- Lucia-Camelia Boldeanu
- Department of Periodontology, Faculty of Dental Medicine, Anton Sculean Research Center for Periodontal and Peri-Implant Diseases, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Marius Boariu
- Department of Endodontics, Faculty of Dental Medicine, TADERP Research Center, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
- Correspondence: (M.B.); (A.P.-W.); Tel.: +40-722701871 (M.B.); +49-15202946197 (A.P.-W.)
| | - Darian Rusu
- Department of Periodontology, Faculty of Dental Medicine, Anton Sculean Research Center for Periodontal and Peri-Implant Diseases, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Adrian Vaduva
- Department of Pathology, Faculty of Medicine, ANAPATMOL Research Center, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Alexandra Roman
- Applicative Periodontal Regeneration Research Unit, Department of Peridontology, Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 400012 Cluj Napoca, Romania
| | - Petra Surlin
- Department of Periodontology, Faculty of Dental Medicine, University of Medicine and Pharmacy, 200349 Craiova, Romania
| | - Ioana Martu
- Department of Dental Technology, Faculty of Dental Medicine Grigore T. Popa University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Razvan Dragoi
- Department of Balneology, Medical Rehabilitation and Rheumatology, Center for Assessment of Movement, Functionality and Disability, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Aurel Popa-Wagner
- Experimental Research Center in Normal and Pathological Aging (ARES), University of Medicine and Pharmacy, 200349 Craiova, Romania
- Correspondence: (M.B.); (A.P.-W.); Tel.: +40-722701871 (M.B.); +49-15202946197 (A.P.-W.)
| | - Stefan-Ioan Stratul
- Department of Periodontology, Faculty of Dental Medicine, Anton Sculean Research Center for Periodontal and Peri-Implant Diseases, “Victor Babes” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| |
Collapse
|
5
|
Comparison of Two Risk Assessment Scores in Predicting Peri-Implantitis Occurrence during Implant Maintenance in Patients Treated for Periodontal Diseases: A Long-Term Retrospective Study. J Clin Med 2022; 11:jcm11061720. [PMID: 35330046 PMCID: PMC8948905 DOI: 10.3390/jcm11061720] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 03/12/2022] [Accepted: 03/17/2022] [Indexed: 12/11/2022] Open
Abstract
Background: There is a need for reliable risk assessment tools to better predict peri-implantitis occurrence. This study compared the long-term prognosis value of two models of risk assessment scoring in predicting peri-implantitis. Methods: Seventy-three patients with treated periodontitis representing 232 implants and attending long-term implant maintenance were evaluated. The Periodontal Risk Assessment (PRA) score, which combines only periodontal risk factors/indicators, and the Implant Risk Assessment (IRA) score, which combines both periodontal and implant risk factors/indicators, were calculated during implant maintenance. Peri-implantitis was defined by the presence of probing depth ≥6 mm with bleeding on probing/suppuration and bone level ≥3 mm. Analyses were performed at the patient level. Results: The mean implant follow-up was 6.5 years. Peri-implantitis incidence was 17.8%, and high-risk PRA and IRA percentages were 36.9% and 27.3%, respectively. High-risk PRA and IRA were significantly associated with peri-implantitis incidence, with hazard ratio (HR) = 4.8 and 3.65, respectively. Risk factors/indicators considered separately showed reduced associations with peri-implantitis. Conclusions: The PRA score combining periodontal parameters and IRA score combining both periodontal and implant parameters have comparable value in predicting peri-implantitis. These scores could allow practicians to intercept the risk of peri-implantitis and to manage follow-up modalities in patients with treated periodontitis.
Collapse
|
6
|
Zhou N, Huang H, Liu H, Li Q, Yang G, Zhang Y, Ding M, Dong H, Mou Y. Microbiota analysis of peri-implant mucositis in patients with periodontitis history. Clin Oral Investig 2022; 26:6223-6233. [PMID: 35672515 PMCID: PMC9525361 DOI: 10.1007/s00784-022-04571-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 05/30/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To investigate the bacterial diversity in peri-implant plaques and the effect of periodontitis history on the occurrence of peri-implant mucositis. MATERIALS AND METHODS Three groups of subgingival plaques were collected from peri-implant sulci in the first molar area. The three groups included healthy implants in patients without periodontitis (NH implant), healthy implants in patients with periodontitis history (PH implant), and peri-implant mucositis implants in patients with periodontitis history (PM implant). Subgingival plaques in periodontal pockets of contralateral natural first molars were also collected. Bacterial DNA was extracted and the V4 region of the 16S rDNA sequence was amplified and sequenced on an Illumina HiSeq platform. The operational taxonomic units obtained from amplicon sequencing were used to analyze the prevalence and identity of bacteria based on public databases and advanced techniques. RESULTS Analysis of similarities indicated a significant difference in bacterial structures between the NH implant and PM implant groups. Additionally, a significantly higher relative abundance of the genera Actinomyces and Streptococcus was found in the samples of the NH implant group. The genera Fusobacterium and Prevotella could be considered as potential biomarkers for peri-implant mucositis. Moreover, more gram-negative anaerobic bacteria (Porphyromonas and Prevotella) were detected in the samples from patients with periodontitis history. CONCLUSIONS The increased accumulation of Fusobacterium and Prevotella is associated with a higher risk of peri-implant mucositis. In addition, patients with periodontal history may be more likely to develop peri-implant mucositis. CLINICAL RELEVANCE The increase in periodontal pathogens and the decrease in health-associated bacteria in patients with periodontitis history may be more likely to develop peri-implant mucositis. These results provide a bacteriological basis for the prevention and treatment of peri-implant mucositis in patients with periodontitis history.
Collapse
Affiliation(s)
- Na Zhou
- Department of Jiangbei, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Haohao Huang
- Department of Oral and Maxillofacial Surgery, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Hui Liu
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Qiang Li
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Guangwen Yang
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Yu Zhang
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Meng Ding
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China
| | - Heng Dong
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.
| | - Yongbin Mou
- Department of Oral Implantology, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.
| |
Collapse
|