1
|
Fedi M, Bobot M, Torrents J, Gobert P, Magnant É, Knefati Y, Verhelst D, Lebrun G, Masson V, Giaime P, Santini J, Bataille S, Brunet P, Dussol B, Burtey S, Mancini J, Daniel L, Jourde-Chiche N. Kidney biopsy in very elderly patients: indications, therapeutic impact and complications. BMC Nephrol 2021; 22:362. [PMID: 34727880 PMCID: PMC8561868 DOI: 10.1186/s12882-021-02559-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 08/10/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Few data is available on the risk/benefit balance of native kidney biopsy (KB) in very elderly patients. METHODS Multicenter retrospective cohort study in the Aix-Marseille area: the results of KB and medical charts of all patients over 85 years biopsied between January 2010 and December 2018 were reviewed. RESULTS 104 patients were included. Median age was 87 years. Indications for KB were: acute kidney injury (AKI) in 69.2% of patients, nephrotic syndrome (NS) with AKI in 13.5%, NS without AKI in 12.5%, and proteinuria in 4.8%. Median serum creatinine was 262 μmol/L, 21% of patients required dialysis at the time of KB. Significant bleeding occurred in 7 (6.7%) patients, requiring blood cell transfusion in 4 (3.8%), and radiological embolization in 1 (1%). The most frequent pathological diagnoses were: non-diabetic glomerular diseases (29.8%, including pauci-immune crescentic glomerulonephritis in 9.6%), hypertensive nephropathy (27.9%), acute interstitial nephritis (16.3%), renal involvement of hematological malignancy (8.7%), and acute tubular necrosis (6.7%). After KB, 51 (49%) patients received a specific treatment: corticosteroids (41.3%), cyclophosphamide (6.7%), rituximab (6.7%), bortezomib (3.8%), other chemotherapies (3.8%). Median overall survival was 31 months. CONCLUSIONS KB can reveal a diagnosis with therapeutic impact even in very elderly patients. Severe bleeding was not frequent in this cohort, but KB may have not been performed in more vulnerable patients.
Collapse
Affiliation(s)
- Mathilde Fedi
- AP-HM, University Hospital of la Conception, Nephrology and Kidney Transplant Centre, Marseille, France
| | - Mickaël Bobot
- AP-HM, University Hospital of la Conception, Nephrology and Kidney Transplant Centre, Marseille, France
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France
| | - Julia Torrents
- AP-HM, University Hospital of La Timone, Anatomical Pathology Laboratory, Marseille, France
| | - Pierre Gobert
- Rhône Durance Clinic, Medicine Department Avignon, Avignon, France
| | - Éric Magnant
- Private Hospital of Provence, Nephrology Department, Aix-en-Provence, France
| | - Yannick Knefati
- Hospital of Sainte Musse, Nephrology Department, Toulon, France
| | - David Verhelst
- Hospital Général Henri Duffaut, Nephrology Department, Avignon, France
| | - Gaëtan Lebrun
- Hospital of Aix en Provence, Nephrology Department, Aix-en-Provence, France
| | - Valérie Masson
- Polyclinic "des fleurs", Nephrology Department, Ollioules, France
| | - Philippe Giaime
- Phocaean Institute of Nephrology, Bouchard Clinic, ELSAN, Marseille, France
| | - Julien Santini
- Saint-Joseph Hospital, Nephrology Department, Marseille, France
| | - Stanislas Bataille
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France
- Phocaean Institute of Nephrology, Bouchard Clinic, ELSAN, Marseille, France
| | - Philippe Brunet
- AP-HM, University Hospital of la Conception, Nephrology and Kidney Transplant Centre, Marseille, France
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France
| | - Bertrand Dussol
- AP-HM, University Hospital of la Conception, Nephrology and Kidney Transplant Centre, Marseille, France
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France
| | - Stéphane Burtey
- AP-HM, University Hospital of la Conception, Nephrology and Kidney Transplant Centre, Marseille, France
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France
| | - Julien Mancini
- Aix Marseille Univ, APHM, Inserm, IRD, SESSTIM, University Hospital of la Timone, BIOSTIC Service, Marseille, France
| | - Laurent Daniel
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France
- AP-HM, University Hospital of La Timone, Anatomical Pathology Laboratory, Marseille, France
| | - Noémie Jourde-Chiche
- AP-HM, University Hospital of la Conception, Nephrology and Kidney Transplant Centre, Marseille, France.
- Aix-Marseille Univ, C2VN, INSERM, INRAE, Marseille, France.
| |
Collapse
|
2
|
Tailliar M, Schanstra JP, Dierckx T, Breuil B, Hanouna G, Charles N, Bascands JL, Dussol B, Vazi A, Chiche L, Siwy J, Faguer S, Daniel L, Daugas E, Jourde-Chiche N. Urinary Peptides as Potential Non-Invasive Biomarkers for Lupus Nephritis: Results of the Peptidu-LUP Study. J Clin Med 2021; 10:jcm10081690. [PMID: 33920017 PMCID: PMC8071029 DOI: 10.3390/jcm10081690] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 04/08/2021] [Accepted: 04/09/2021] [Indexed: 12/16/2022] Open
Abstract
Background: Lupus nephritis (LN) is a severe manifestation of Systemic Lupus Erythematosus (SLE). The therapeutic strategy relies on kidney biopsy (KB) results. We tested whether urinary peptidome analysis could non-invasively differentiate active from non-active LN. Design: Urinary samples were collected from 93 patients (55 with active LN and 38 with non-active LN), forming a discovery (n = 42) and an independent validation (n = 51) cohort. Clinical characteristics were collected at inclusion and prospectively for 24 months. The urinary peptidome was analyzed by capillary-electrophoresis coupled to mass-spectrometry, comparing active LN to non-active LN, and assessing chronic lesions and response to therapy. The value of previously validated prognostic (CKD273) and differential diagnostic (LN172) signatures was evaluated. Results: Urinary peptides could not discriminate between active and non-active LN or predict early response to therapy. Tubulo-interstitial fibrosis was correlated to the CKD273. The LN172 score identified 92.5% of samples as LN. Few patients developed new-onset CKD. Conclusions: We validated the CKD273 and LN172 classifiers but did not identify a robust signature that could predict active LN and replace KB. The value of urinary peptidome to predict long-term CKD, or renal flares in SLE, remains to be evaluated.
Collapse
Affiliation(s)
- Maxence Tailliar
- AP-HM, Centre de Néphrologie et Transplantation Rénale, Hôpital de la Conception, 13005 Marseille, France; (M.T.); (B.D.)
| | - Joost P. Schanstra
- Institut National de la Santé et de la Recherche Médicale (INSERM), U1297, Institut of Metabolic and Cardiovascular Disease (I2MC), 31432 Toulouse, France; (J.P.S.); (B.B.); (S.F.)
- Université Toulouse III Paul-Sabatier, 31062 Toulouse, France
| | - Tim Dierckx
- Laboratory of Clinical and Epidemiological Virology, Department of Microbiology and Immunology, Rega Institute for Medical Research, KU Leuven, 3000 Leuven, Belgium;
| | - Benjamin Breuil
- Institut National de la Santé et de la Recherche Médicale (INSERM), U1297, Institut of Metabolic and Cardiovascular Disease (I2MC), 31432 Toulouse, France; (J.P.S.); (B.B.); (S.F.)
- Université Toulouse III Paul-Sabatier, 31062 Toulouse, France
| | - Guillaume Hanouna
- AP-HP, Service de Néphrologie, Hôpital Bichat, DMU VICTOIRE, 75018 Paris, France; (G.H.); (E.D.)
| | - Nicolas Charles
- Centre de Recherche sur l’Inflammation, Université de Paris, INSERM UMRS1149, CNRS ERL8252, Labex INFLAMEX, DHU FIRE, 75890 Paris, France;
| | - Jean-Loup Bascands
- Institut National de la Santé et de la Recherche Médicale (INSERM), U1188-Université de La Réunion, 97490 Saint-Denis, France;
| | - Bertrand Dussol
- AP-HM, Centre de Néphrologie et Transplantation Rénale, Hôpital de la Conception, 13005 Marseille, France; (M.T.); (B.D.)
- Centre d’Investigation Clinique, CHU Conception, AP-HM, 13005 Marseille, France;
| | - Alain Vazi
- Centre d’Investigation Clinique, CHU Conception, AP-HM, 13005 Marseille, France;
| | - Laurent Chiche
- Médecine Interne, Hôpital Européen, 13003 Marseille, France;
| | - Justyna Siwy
- Mosaiques Diagnostics GmbH, 30659 Hannover, Germany;
| | - Stanislas Faguer
- Institut National de la Santé et de la Recherche Médicale (INSERM), U1297, Institut of Metabolic and Cardiovascular Disease (I2MC), 31432 Toulouse, France; (J.P.S.); (B.B.); (S.F.)
- Université Toulouse III Paul-Sabatier, 31062 Toulouse, France
- CHU de Toulouse, Service de Néphrologie, 31300 Toulouse, France
| | - Laurent Daniel
- AP-HM, Laboratoire d’Ananatomie Pathologique, Hôpital de la Timone, 13005 Marseille, France;
- Center for CardioVascular and Nutrition Research (C2VN), Aix-Marseille University, INSERM, INRAE, 13005 Marseille, France
| | - Eric Daugas
- AP-HP, Service de Néphrologie, Hôpital Bichat, DMU VICTOIRE, 75018 Paris, France; (G.H.); (E.D.)
- Centre de Recherche sur l’Inflammation, Université de Paris, INSERM UMRS1149, CNRS ERL8252, Labex INFLAMEX, DHU FIRE, 75890 Paris, France;
| | - Noémie Jourde-Chiche
- AP-HM, Centre de Néphrologie et Transplantation Rénale, Hôpital de la Conception, 13005 Marseille, France; (M.T.); (B.D.)
- Center for CardioVascular and Nutrition Research (C2VN), Aix-Marseille University, INSERM, INRAE, 13005 Marseille, France
- Correspondence:
| | | |
Collapse
|
3
|
|
4
|
Sousanieh G, Whittier WL, Rodby RA, Peev V, Korbet SM. Percutaneous Renal Biopsy Using an 18-Gauge Automated Needle Is Not Optimal. Am J Nephrol 2021; 51:982-987. [PMID: 33454708 DOI: 10.1159/000512902] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Accepted: 11/06/2020] [Indexed: 11/19/2022]
Abstract
BACKGROUND As percutaneous renal biopsies (PRBs) are increasingly performed by radiologists, an increase in the use of 18-gauge automated needle stands to compromise adequacy. We compare the adequacy and safety of PRB with 14-, 16-, and 18-gauge automated needles. METHODS PRB of native (N-592) and transplant (T-1,023) kidneys was performed from January 2002 to December 2019 using real-time ultrasound. Baseline clinical and laboratory data, biopsy data (number of cores, total glomeruli, and total glomeruli per core), and outcome (hematoma on renal US at 1-h, complications, and transfusion) were collected prospectively. PRB with N14g (337) versus N16g (255) and T16g (892) versus T18g (131) needles were compared. A p value of <0.05 was significant. RESULTS PRB with an 18-g needle yielded the lowest number of total glomeruli per biopsy (N14g vs. N16g: 33 ± 13 vs. 29 ± 12, p < 0.01 and T16g vs. T18g: 34 ± 16 vs. 21 ± 11, p < 0.0001), significantly fewer total glomeruli per core (T16g vs. T18g: 12.7 ± 6.4 vs. 9.6 ± 5.0, p < 0.001 and N16g vs. T18g: 14.2 ± 6.3 vs. 9.6 ± 5.0, p < 0.001). A hematoma by renal US 1-h post-PRB was similar for native (14g-35% vs. 16g-29%, p = 0.2), and transplant biopsies (16g-10% vs. 18g-9%, p = 0.9) and the complication rate for native (14g-8.9% vs. 16g-7.1%, p = 0.5), transplant biopsies (16g-4.6% vs. 18g-1.5%, p = 0.2) and transfusion rate for native (14g-7.7% vs. 16g-5.8%, p = 0.4), and transplant biopsies (16g-3.8% vs. 18g-0.8%, p = 0.1) were similar irrespective of needle size. CONCLUSIONS PRB of native and transplant kidneys with the use of a 16-gauge needle provides an optimal sample. However, our experience in transplant biopsies suggests the use of an 18-gauge needle stands to jeopardize the diagnostic accuracy of the PRB while not improving safety.
Collapse
Affiliation(s)
- George Sousanieh
- Division of Nephrology, Department of Internal Medicine, Rush University Medical Center, Chicago, Illinois, USA
| | - William L Whittier
- Division of Nephrology, Department of Internal Medicine, Rush University Medical Center, Chicago, Illinois, USA
| | - Roger A Rodby
- Division of Nephrology, Department of Internal Medicine, Rush University Medical Center, Chicago, Illinois, USA
| | - Vasil Peev
- Division of Nephrology, Department of Internal Medicine, Rush University Medical Center, Chicago, Illinois, USA
| | - Stephen M Korbet
- Division of Nephrology, Department of Internal Medicine, Rush University Medical Center, Chicago, Illinois, USA,
| |
Collapse
|
5
|
Xu J, Wu X, Xu Y, Ren H, Wang W, Chen W, Shen P, Li X, Shi H, Xie J, Chen X, Zhang W, Pan X. Acute Kidney Disease Increases the Risk of Post-Kidney Biopsy Bleeding Complications. Kidney Blood Press Res 2020; 45:873-882. [PMID: 33105145 DOI: 10.1159/000509443] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 06/15/2020] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION Kidney biopsy, providing the insightful information for most kidney diseases, is an invasive diagnostic tool with certain risks ranging from the least severe macroscopic hematuria to the most severe life-threatening bleeding necessitating renal artery embolization. We aimed to compare the postbiopsy bleeding complications between 2 common methods and to further explore the risk factors of bleeding complications in patients using the negative pressure suction puncture (NPS) method. METHODS We retrospectively collected the data from percutaneous native kidney biopsies in 2016. The clinical, laboratory tests, pathological findings, and the occurrence of bleeding complications following kidney biopsy were analyzed. The kidney biopsy was performed in our center by experienced nephrologists with 2 different methods, namely, NPS method and real-time ultrasound-guided needle (RTU) method. We compared rates of complications between 2 methods and evaluated univariate and multivariate association of risk factors with bleeding complications in the NPS group. RESULTS 626 kidney biopsies were performed between January 2016 and December 2016. There were 83.2% (521/626) participants in the NPS group and 16.8% (105/626) in the RTU group. There were more participants in the RTU group needing >1 needle pass during biopsy than those in the NPS group (61.0 vs. 14.7%, p < 0.001). Acute kidney disease (AKD) occurred before the procedure of kidney biopsy accounted for 13.8% (72/521) in the NPS group and 1.9% (2/105) in the RTU group. The renal pathological findings revealed higher number of glomeruli in the NPS group than in the RTU group (26.8 ± 13.0 vs. 17.2 ± 8.6, p < 0.001). The incidence of bleeding complications in the NPS group was lower than that in the RTU group (9.2 vs. 21.9%, p < 0.01). Logistic multivariate regression showed that AKD was independently associated with bleeding complications after kidney biopsy in the NPS group. CONCLUSION Regarding the bleeding risk, there was noninferiority of NPS over RTU. AKD contributes to higher risks of bleeding complications after kidney biopsy.
Collapse
Affiliation(s)
- Jing Xu
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Xiaojing Wu
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Yaowen Xu
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Hong Ren
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Weiming Wang
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Weihong Chen
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Pingyan Shen
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Xiao Li
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Hao Shi
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Jingyuan Xie
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Xiaonong Chen
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Wen Zhang
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Xiaoxia Pan
- Department of Nephrology, Ruijin Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China,
| |
Collapse
|
6
|
MacGinley R, Champion De Crespigny PJ, Gutman T, Lopez-Vargas P, Manera K, Menahem S, Saunders J, See E, Voss D, Wong J. KHA-CARI Guideline recommendations for renal biopsy. Nephrology (Carlton) 2019; 24:1205-1213. [PMID: 31490584 DOI: 10.1111/nep.13662] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 08/13/2019] [Accepted: 08/17/2019] [Indexed: 01/17/2023]
Affiliation(s)
- Rob MacGinley
- Department of Renal and General Medicine, Eastern Health Clinical School, Monash University Melbourne, Melbourne, Victoria, Australia
| | - Paul J Champion De Crespigny
- Department of Nephrology, The Royal Melbourne Hospital, Melbourne, Victoria, Australia.,Royal Women's Hospital, Melbourne, Victoria, Australia
| | - Talia Gutman
- Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Sydney, New South Wales, Australia
| | - Pamela Lopez-Vargas
- Centre for Kidney Research, The Children's Hospital at Westmead, Sydney, New South Wales, Australia
| | - Karine Manera
- Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Sydney, New South Wales, Australia
| | - Solomon Menahem
- Department of Epidemiology and Preventative Medicine, Monash University, Melbourne, Victoria, Australia
| | - John Saunders
- Renal Unit, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Emily See
- Department of Nephrology, Monash Health, Melbourne, Victoria, Australia
| | - David Voss
- Counties Manukau Health, Auckland, New Zealand
| | - Jeffrey Wong
- Department of Nephrology, Liverpool Hospital, Liverpool, New South Wales, Australia
| |
Collapse
|
7
|
Gutman T, Lopez-Vargas P, Manera KE, Craig JC, Howell M, Tunnicliffe D, James LJ, MacGinley R, See E, Wong J, Voss D, Saunders J, Menahem S, Jesudason S, Tong A, Champion de Crespigny P. Identifying and integrating patient and caregiver perspectives in clinical practice guidelines for percutaneous renal biopsy. Nephrology (Carlton) 2019; 24:395-404. [PMID: 29797384 DOI: 10.1111/nep.13406] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/18/2018] [Indexed: 12/23/2022]
Abstract
AIM Percutaneous renal biopsy is often essential for providing reliable diagnostic and prognostic information for people with suspected kidney disease, however the procedure can lead to complications and concerns among patients. This study aims to identify and integrate patient priorities and perspectives into the Kidney Health Australia - Caring for Australasians with Renal Impairment clinical practice guidelines for renal biopsy, to ensure patient-relevance. METHODS We convened a workshop, consisting of three simultaneous focus groups and a plenary session, with 10 patients who had undergone a renal biopsy and seven caregivers. Topics and outcomes prioritized by patients and their caregivers were compared to those identified by the guideline working group, which was comprised of seven nephrologists. Transcripts and flipcharts were analyzed thematically to identify the reasons for participants' choices. RESULTS In total, 34 topics/outcomes were identified, 14 of which were common to the list of 28 previously identified by the guideline working group. Most of the new topics identified by patients/caregivers were related to communication and education, psychosocial support, and self-management. We identified five themes underpinning the reasons for topic and outcome selection: alleviating anxiety and unnecessary distress, minimizing discomfort and disruption, supporting family and caregivers, enabling self-management, and protecting their kidney. A new topic on patient care and education was added to the guideline as a result. CONCLUSIONS Patient and caregiver involvement in developing guidelines on renal biopsy ensured that their concerns and needs for education, psychosocial support, and self-management were explicitly addressed; enabling a patient-centred approach to renal biopsies.
Collapse
Affiliation(s)
- Talia Gutman
- Sydney School of Public Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - Pamela Lopez-Vargas
- Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - Karine E Manera
- Sydney School of Public Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - Jonathan C Craig
- Sydney School of Public Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - Martin Howell
- Sydney School of Public Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - David Tunnicliffe
- Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - Laura J James
- Sydney School of Public Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | - Rob MacGinley
- Eastern Health Clinical School, Monash University, Melbourne, Victoria, Australia
| | - Emily See
- Department of Nephrology, Monash Health, Melbourne, Victoria, Australia
| | - Jeffrey Wong
- Department of Nephrology, Liverpool Hospital, Sydney, New South Wales, Australia
| | - David Voss
- Department of Renal Medicine, Counties Manukau Health, Auckland, New Zealand
| | - John Saunders
- Renal Unit, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Solomon Menahem
- Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
| | - Shilpanjali Jesudason
- Central and Northern Adelaide Renal and Transplantation Service and Department of Medicine, University of Adelaide, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Allison Tong
- Sydney School of Public Health, The University of Sydney, Sydney, New South Wales, Australia.,Centre for Kidney Research, The Children's Hospital at Westmead, Westmead, New South Wales, Australia
| | | |
Collapse
|
8
|
Pongsittisak W, Wutilertcharoenwong N, Ngamvichchukorn T, Kurathong S, Chavanisakun C, Teepprasan T, Prommool S, Srisawat N. The efficacy of blind versus real-time ultrasound-guided percutaneous renal biopsy in developing country. SAGE Open Med 2019; 7:2050312119849770. [PMID: 31205694 PMCID: PMC6537046 DOI: 10.1177/2050312119849770] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Accepted: 04/17/2019] [Indexed: 02/06/2023] Open
Abstract
Introduction: Renal biopsy is a useful diagnostic procedure. In developing countries, two techniques of renal biopsy, blind percutaneous renal biopsy and real-time ultrasound-guided percutaneous renal biopsy, have been performed. The majority of studies compared these using different types and sizes of biopsy needle. The aim of this study was to compare both techniques in resource constraint country. Method: We reviewed renal biopsy database, between 1 January 2014 to 30 June 2017. The primary outcome was the total number of glomeruli. The other outcomes were tissue adequacy and bleeding complications. We also analyzed multivariable logistic regression to find factors associated with tissue adequacy and bleeding complications. Result: Of the 204 renal biopsies, 100 were blind percutaneous renal biopsy and 104 real-time ultrasound-guided percutaneous renal biopsy. The number of native renal biopsies was 169 (82.8%). Baseline characteristics of two groups were comparable. The mean number of total glomeruli from real-time ultrasound-guided percutaneous renal biopsy was significantly more than blind percutaneous renal biopsy (20.8 ± 12.1 vs 16.0 ± 13.0, p = 0.001). The real-time ultrasound-guided percutaneous renal biopsy obtained more adequate tissues than blind percutaneous renal biopsy (45.2% vs 16%, p < 0.001) and was the only factor associated with adequate tissue. Moreover, 16 renal biopsies from blind percutaneous renal biopsy obtained inadequate tissue. The overall bleeding complications were not statistically different. We found being female, lower eGFR and lower hematocrit were associated with bleeding complications. Conclusion: In comparison with blind percutaneous renal biopsy, real-time ultrasound-guided percutaneous renal biopsy obtained more adequate tissue and number of glomeruli. While the complications of both were comparable. We encourage to practice and perform real-time ultrasound-guided percutaneous renal biopsy in resource constraint countries.
Collapse
Affiliation(s)
- Wanjak Pongsittisak
- Division of Nephrology, Department of Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Naphat Wutilertcharoenwong
- Division of Nephrology, Department of Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Tanun Ngamvichchukorn
- Division of Nephrology, Department of Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Sathit Kurathong
- Division of Nephrology, Department of Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Chutima Chavanisakun
- Department of Pathology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Tavichai Teepprasan
- Division of Nephrology, Department of Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Surazee Prommool
- Division of Nephrology, Department of Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Nattachai Srisawat
- Division of Nephrology, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
9
|
Diagnostic efficacy and safety of ultrasound-guided kidney transplant biopsy using cortex-only view: a retrospective single-center study. Eur Radiol 2018; 29:5272-5279. [PMID: 30560360 DOI: 10.1007/s00330-018-5910-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 10/24/2018] [Accepted: 11/22/2018] [Indexed: 01/08/2023]
Abstract
PURPOSE Cortical biopsy is the cornerstone to reveal a cause of unexplained dysfunction of the kidney transplant. Nevertheless, only a few studies have reported the biopsy technique with its performance. We described a novel technique of ultrasound (US)-guided kidney transplant biopsy using cortex-only view and analyzed its diagnostic efficacy and safety. MATERIALS AND METHODS Between January 2014 and December 2016, a consecutive series of 188 patients who underwent US-guided kidney transplant biopsy using cortex-only view by an experienced radiologist were evaluated (mean age, 46.1 ± 12.5 years; range, 21-79 years). Biopsy time, biopsy distance, biopsy core number, and glomerular number per patient were recorded. Successful biopsy (e.g., adequate, 10 or more glomeruli; marginal, 7-9 glomeruli) and complication rates were investigated, using Banff criteria and Clavien-Dindo classification, respectively. RESULTS Mean biopsy time, distance, and core number were 20.6 ± 6.7 min (range, 10-44 min), 3.2 ± 0.7 cm (range, 2.1-5.4 cm), and 1.9 ± 0.3 (range, 1.0-3.0), respectively. Mean glomerular number per patient was 20.4 ± 10.0 (range, 0-54). Adequate and marginal biopsy rates were 87.2% (164/188) and 95.2% (179/188), respectively. There was no major complication requiring treatment (no patient with Clavien-Dindo grade 2 or greater complication), while there were self-limiting minor complications in 5 patients (overall complication rate, 2.7%). CONCLUSION US-guided biopsy using cortex-only view is feasible and safe in sampling cortical tissues of kidney transplant. KEY POINTS • Ultrasound (US)-guided kidney transplant biopsy using cortex-only view is feasible and safe. • Adequate and marginal biopsy rates were 87.2% and 95.2%, respectively. • No major complication requiring treatment occurred after biopsy.
Collapse
|
10
|
Li J, Chen Y, Shen L, Deng Y. Improvement of membranous nephropathy by inhibition of miR-193a to affect podocytosis via targeting WT1. J Cell Biochem 2018; 120:3438-3446. [PMID: 30242881 DOI: 10.1002/jcb.27616] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 08/14/2018] [Indexed: 12/22/2022]
Abstract
The objective of this paper was to explore the role and molecular mechanism of miR-193a in membranous nephropathy (MN). Experimental rats and podocytes were randomly divided into four groups: control, MN, miR-NC, and miR-193a inhibitor groups. The relative mRNA level of miR-193a was determined. The mRNA level and protein expression of PODXL, NPHS1, and Notch1 were determined by real-time polymerase chain reaction (RT-PCR) and Western blot analysis, respectively. The mRNA level and protein expression of WT1 in podocytes were also determined by RT-PCR and Western blot analysis. The relative mRNA level of miR-193a in the MN group was significantly higher than that in the control group, and inhibition of miR-193a inhibited the increase successfully. Inhibition of miR-193a inhibited renal injury, podocyte injury, and tissue cell apoptosis resulting from MN. The expression of PODXL, NPHS1, and Notch1 was decreased in the MN group, while the expression was increased in the miR-193a inhibitor group. WT1 was verified as a target gene of miR-193a and the expression of WT1 increased after inhibition of miR-193a. Inhibition of miR-193a by targeting WT1 could inhibit renal function injury, renal tissue cell apoptosis, and podocytosis.
Collapse
Affiliation(s)
- Jiao Li
- Department of Nephrology, Longhua Hospital Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Yi Chen
- Department of Nephrology, Longhua Hospital Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Lianli Shen
- Department of Nephrology, Longhua Hospital Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Yueyi Deng
- Department of Nephrology, Longhua Hospital Shanghai University of Traditional Chinese Medicine, Shanghai, China
| |
Collapse
|
11
|
Whittier WL, Gashti C, Saltzberg S, Korbet S. Comparison of native and transplant kidney biopsies: diagnostic yield and complications. Clin Kidney J 2018; 11:616-622. [PMID: 30289130 PMCID: PMC6165758 DOI: 10.1093/ckj/sfy051] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Accepted: 05/18/2018] [Indexed: 01/20/2023] Open
Abstract
Background The safety and adequacy are established for the native percutaneous renal biopsy (PRB) but no prospective studies exist that directly compare these with transplant PRB. Methods From 1995 to 2015, 1705 adults underwent percutaneous native [native renal biopsy (NRB)] or transplant renal biopsy (TRB) by the Nephrology service. Real-time ultrasound and automated biopsy needles (NRB, 14 or 16 gauge; TRB, 16 gauge) were used. Patients were observed for 24 h (NRB) or 8 h (TRB) post-procedure. Adequacy was defined as tissue required for diagnosis plus glomerular yield. Complications were defined as those resulting in the need for an intervention, such as surgery, interventional radiologic procedure, readmission, blood transfusion and death. Data were collected prospectively in all biopsies. Results At the time of biopsy, NRB patients were younger (mean ± SD, 47 ± 17 versus 50 ± 14 years, P < 0.0001) and more often female (62 versus 48%, P < 0.0001) compared with TRB. A fellow supervised by an attending performed the procedure in 91% of NRB compared with 63% of TRB (P < 0.0001). TRB patients were more hypertensive [systolic blood pressure (SBP) 140 ± 22 versus 133 ± 18 mmHg, P < 0.0001] and had a higher serum creatinine (3.1 ± 1.8 versus 2.3 ± 2.2 mg/dL, P < 0.0001), activated partial thromboplastin time (28 ± 4.3 versus 27 ± 5 s, P < 0.0001) as well as lower hemoglobin (Hgb) (11.2 ± 1.8 versus 11.7 ± 2.1 g/dL, P < 0.0001) compared with NRB. Adequate tissue for diagnosis was obtained in > 99% of NRB and TRB (P = 0.71). Compared with TRB, NRB had a greater drop in Hgb after the biopsy (0.97 ± 1.1 versus 0.73 ± 1.3 g/dL, P < 0.0001), a higher complication rate (6.5 versus 3.9%, P = 0.02) and higher transfusion rate (5.2 versus 3.3%, P = 0.045). There was one death in each group attributed to the biopsy. Conclusions Although death is equally rare, the complication rate is higher in NRB compared with TRB despite TRB having more of the traditional risk factors for bleeding. Differences in technique, operator (fellow or attending) or needle gauge may explain this variability.
Collapse
Affiliation(s)
- William L Whittier
- Division of Nephrology, Rush University Medical Center, Chicago, IL, USA
| | - Casey Gashti
- Division of Nephrology, Rush University Medical Center, Chicago, IL, USA
| | - Samuel Saltzberg
- Division of Nephrology, Rush University Medical Center, Chicago, IL, USA
| | - Stephen Korbet
- Division of Nephrology, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
12
|
Jourde-Chiche N, Whalen E, Gondouin B, Speake C, Gersuk V, Dussol B, Burtey S, Pascual V, Chaussabel D, Chiche L. Modular transcriptional repertoire analyses identify a blood neutrophil signature as a candidate biomarker for lupus nephritis. Rheumatology (Oxford) 2017; 56:477-487. [PMID: 28031441 DOI: 10.1093/rheumatology/kew439] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Indexed: 01/09/2023] Open
Abstract
Objective LN is a severe complication of SLE. Non-invasive biomarkers are needed for identifying patients at risk of a renal flare, for differentiating proliferative from non-proliferative forms and for assessing prognoses for LN. Methods We assessed the link between blood transcriptional signatures and LN using blood samples from patients with biopsy-proven LN, extra-renal SLE flares or quiescent SLE. Healthy controls, and control patients with glomerular diseases or bacterial sepsis were included. Modular repertoire analyses from microarray data were confirmed by PCR. Results A modular neutrophil signature (upregulation of module M5.15) was present in 65% of SLE patients and was strongly associated with LN. M5.15 activity was stronger in LN than in extra-renal flares (88 vs 17%). M5.15 was neither correlated to IFN modules, nor to SLEDAI or anti-dsDNA antibodies, but moderately to CS dose. M5.15 activity was associated with severity of LN, was stronger when proliferative, and decreased in patients responding to treatment. M5.15 activation was not caused by higher CS dose because it correlated only moderately to neutrophil count and was also observed among quiescent patients. Among quiescent patients, those with a past history of LN had higher M5.15 activity (50 vs 8%). M5.15 activation was present in patients with bacterial sepsis or ANCA-associated vasculitis, but not in patients with other glomerular diseases. Overall, M5.15 activation was associated with past, present or future flares of LN. Conclusion Modular neutrophil signature could be a biomarker for stratifying LN risk and for monitoring its response to treatment. Trial registration ClinicalTrials.gov, http://clinicaltrials.gov , NCT00920114.
Collapse
Affiliation(s)
- Noémie Jourde-Chiche
- Department of Nephrology, Aix-Marseille University, AP-HM, Hôpital Conception, UMR_S 1076, Vascular Research Center of Marseille, Marseille, France
| | - Elizabeth Whalen
- Systems Immunology Department, Benaroya Research Institute, Seattle
| | - Bertrand Gondouin
- Department of Nephrology, Aix-Marseille University, AP-HM, Hôpital Conception, UMR_S 1076, Vascular Research Center of Marseille, Marseille, France
| | - Cate Speake
- Systems Immunology Department, Benaroya Research Institute, Seattle
| | - Vivian Gersuk
- Systems Immunology Department, Benaroya Research Institute, Seattle
| | - Bertrand Dussol
- Department of Nephrology, Aix-Marseille University, AP-HM, Hôpital Conception, UMR_S 1076, Vascular Research Center of Marseille, Marseille, France
| | - Stephane Burtey
- Department of Nephrology, Aix-Marseille University, AP-HM, Hôpital Conception, UMR_S 1076, Vascular Research Center of Marseille, Marseille, France
| | - Virginia Pascual
- Immunology, Baylor Institute for Immunology Research, Dallas, TX, USA
| | - Damien Chaussabel
- Systems Biology Department, Sidra Medical and Research Center, Doha, Qatar
| | - Laurent Chiche
- Department of Internal Medicine, Hôpital Européen, Marseille, France
| |
Collapse
|
13
|
Chunduri S, Whittier WL, Korbet SM. Adequacy and Complication Rates with 14- vs. 16-gauge Automated Needles in Percutaneous Renal Biopsy of Native Kidneys. Semin Dial 2014; 28:E11-4. [PMID: 25441680 DOI: 10.1111/sdi.12332] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Svetha Chunduri
- Section of Nephrology; Department of Medicine; Rush University Medical Center; 1653 West Congress Pkwy Chicago Illinois 60612
| | - William L. Whittier
- Section of Nephrology; Department of Medicine; Rush University Medical Center; 1653 West Congress Pkwy Chicago Illinois 60612
| | - Stephen M. Korbet
- Section of Nephrology; Department of Medicine; Rush University Medical Center; 1653 West Congress Pkwy Chicago Illinois 60612
| |
Collapse
|
14
|
Chen W, Lin X, Huang J, Tan K, Chen Y, Peng W, Li W, Dai Y. Integrated profiling of microRNA expression in membranous nephropathy using high-throughput sequencing technology. Int J Mol Med 2013; 33:25-34. [PMID: 24220188 PMCID: PMC3868500 DOI: 10.3892/ijmm.2013.1554] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Accepted: 10/15/2013] [Indexed: 12/16/2022] Open
Abstract
The present study analyzed microRNA (miRNA) expression profiles in peripheral blood lymphocyte cells (PBLCs) from patients with membranous nephropathy (MN) and normal controls (NC), in an effort to improve the understanding of the pathogenesis of MN. High-throughput sequencing was performed on 30 MN patients and 30 healthy individuals (NC group). Known and novel miRNAs were analyzed and the results were confirmed by quantitative reverse transcription PCR (qRT-PCR). In total, 326 miRNAs showed a significant difference in expression between the MN and NC groups. This included 286 downregulated miRNAs and 40 upregulated miRNAs. In addition, there were 6 novel miRNAs that presented differential levels of expression between the MN and NC groups. The miRNAs were mapped to the genome, using a short oligonucleotide alignment program (SOAP), to analyze their expression and distribution. Twenty-five percent of the unique miRNAs in the MN group and 52.1% in the NC group were mapped to the genome. One hundred and eight mismatches were identified. Seventy-seven mismatches were detected in a higher proportion of the MN samples, compared with the NC samples. Twenty-five mismatches were detected in a higher proportion of the NC samples than the MN samples. Differential miRNA expression was also detected between 10 randomly selected pair groups, as depicted in a cluster analysis diagram. These data indicate that differential miRNA expression may be involved in the pathogenesis of MN. In addition, the discrepancies between the MN and NC groups, in the mismatched miRNAs that were mapped to the genome, strongly suggest that miRNAs play an important role in the pathogenesis of human disorders. miRNAs may provide a potential breakthrough in the research of MN and may provide a novel biomarker for the diagnosis and treatment of the disease.
Collapse
Affiliation(s)
- Wenbiao Chen
- Second Clinical Medical College of Jinan University, Shenzhen People's Hospital, Shenzhen, Guangdong, P.R. China
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Schmid A, Jacobi J, Kuefner MA, Lell M, Wuest W, Mayer-Kadner I, Benz K, Schmid M, Amann K, Uder M. Transvenous Renal Transplant Biopsy via a Transfemoral Approach. Am J Transplant 2013; 13:1262-71. [PMID: 23489636 DOI: 10.1111/ajt.12199] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2012] [Revised: 11/27/2012] [Accepted: 01/17/2013] [Indexed: 01/25/2023]
Abstract
Percutaneous renal biopsy (PRB) of kidney transplants might be prevented by an elevated risk of bleeding or limited access to the allograft. In the following, we describe our initial experience with 71 transvenous renal transplant biopsies in 53 consecutive patients with unexplained reduced graft function who were considered unsuitable candidates for PRB (4.2% of all renal transplant biopsies at our institution). Biopsies were performed via the ipsilateral femoral vein with a renal biopsy set designed for transjugular renal biopsy (TJRB) of native kidneys. Positioning of the biopsy system within the transplant vein was achievable in 58 of 71 (81.7%) procedures. The specimen contained a median of 10 glomeruli (range 0-38). Tissue was considered as adequate for diagnosis in 56 of 57 (98.2%) biopsies. With respect to BANFF 50.9% of the specimen were adequate (>10 glomeruli), 47.4% marginally adequate (1-9 glomeruli) and 1.8% inadequate (no glomeruli). After implementation of real-time assessment all specimen contained glomeruli. One of the fifty-eight (1.8%) procedure-related major complications occurred (hydronephrosis requiring nephrostomy due to gross hematuria). Transfemoral renal transplant biopsy (TFRTB) is feasible and appears to be safe compared to PRB. It offers a useful new alternative for histological evaluation of graft dysfunction in selected patients with contraindications to PRB.
Collapse
Affiliation(s)
- A Schmid
- Department of Radiology, University of Erlangen-Nuremberg, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Year in review in Intensive Care Medicine 2012: I. Neurology and neurointensive care, epidemiology and nephrology, biomarkers and inflammation, nutrition, experimentals. Intensive Care Med 2012; 39:232-46. [PMID: 23248038 PMCID: PMC3569582 DOI: 10.1007/s00134-012-2774-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Accepted: 11/29/2012] [Indexed: 01/06/2023]
|
17
|
Korbet SM, Volpini KC, Whittier WL. Percutaneous renal biopsy of native kidneys: a single-center experience of 1,055 biopsies. Am J Nephrol 2004; 39:153-62. [PMID: 24526094 DOI: 10.1159/000358334] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Accepted: 12/31/2013] [Indexed: 12/16/2022]
Abstract
BACKGROUND Percutaneous renal biopsy (PRB) of native kidneys is an essential tool in the diagnosis and management of renal disease. We report one of the largest single-center experiences on the success and safety of the procedure. METHODS From June 1983 to March 2012, 1,055 adults underwent PRB using real-time ultrasound guidance and 14-gauge biopsy needles. Data were collected prospectively for 826 biopsies (78%). Statistical analysis was performed using the Mann-Whitney test, Wilcoxon matched pairs test and Kruskal-Wallis test for continuous data or the Fisher's exact test and χ(2) test for categorical data. Multivariate analysis using logistic regression was performed to determine which feature at baseline was predictive of a complication following renal biopsy. RESULTS Patients were aged 46 ± 17 years; 38% were male, 40% were white and 43% were African-American. Serum creatinine (SCr) was 2.3 ± 2.3 mg/dl (>1.5 mg/dl in 47%). The pre-PRB hemoglobin was 12 ± 2 g/dl (<11.0 g/dl in 35%). Adequate tissue for diagnosis was obtained in 99% of biopsies. Minor complications occurred in 8.1% of biopsies (mainly gross hematuria, in 4.5%). Major complications occurred in 6.6% of biopsies, with transfusions required in 5.3%. Only 1 death (0.09%) resulted from post-PRB bleeding. By multivariate analysis, baseline features predictive of a complication were systolic blood pressure >170 mm Hg (OR 4.2, 95% CI 1.8-9.8), bleeding time >7.5 min (OR 1.7, CI 1.2-2.5) and SCr >3.5 mg/dl (OR 1.8, CI 1.2-2.9). CONCLUSIONS PRB of native kidneys using real-time ultrasound with a 14-gauge automated needle remains a successful and safe procedure.
Collapse
Affiliation(s)
- Stephen M Korbet
- Section of Nephrology, Department of Medicine, Rush University Medical Center, Chicago, Ill., USA
| | | | | |
Collapse
|