Janeca A, Rodrigues FSC, Gonçalves MC, Faria M. Novel Cellulose Acetate-Based Monophasic Hybrid Membranes for Improved Blood Purification Devices: Characterization under Dynamic Conditions. MEMBRANES 2021; 11:825. [PMID: 34832054 PMCID: PMC8624022 DOI: 10.3390/membranes11110825] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 10/23/2021] [Accepted: 10/25/2021] [Indexed: 02/01/2023]
Abstract
A novel cellulose acetate-based monophasic hybrid skinned amine-functionalized CA-SiO2-(CH2)3NH2 membrane was synthesized using an innovative method which combines the phase inversion and sol-gel techniques. Morphological characterization was performed by scanning electron microscopy (SEM), and the chemical composition was analyzed by Fourier transform infrared spectroscopy in attenuated total reflection mode (ATR-FTIR). The characterization of the monophasic hybrid CA-SiO2-(CH2)3NH2 membrane in terms of permeation properties was carried out in an in-house-built single hemodialysis membrane module (SHDMM) under dynamic conditions. Permeation experiments were performed to determine the hydraulic permeability (Lp), molecular weight cut-off (MWCO) and the rejection coefficients to urea, creatinine, uric acid, and albumin. SEM confirmed the existence of a very thin (<1 µm) top dense layer and a much thicker bottom porous surface, and ATR-FTIR showed the main bands belonging to the CA-based membranes. Permeation studies revealed that the Lp and MWCO of the CA-SiO2-(CH2)3NH2 membrane were 66.61 kg·h-1·m-2·bar-1 and 24.5 kDa, respectively, and that the Lp was 1.8 times higher compared to a pure CA membrane. Furthermore, the CA-SiO2-(CH2)3NH2 membrane fully permeated urea, creatinine, and uric acid while completely retaining albumin. Long-term filtration studies of albumin solutions indicated that fouling does not occur at the surface of the CA-SiO2-(CH2)3NH2 membrane.
Collapse
Affiliation(s)
- Adriana Janeca
- Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal; (A.J.); (F.S.C.R.); (M.C.G.)
| | - Flávia S. C. Rodrigues
- Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal; (A.J.); (F.S.C.R.); (M.C.G.)
- CeFEMA, Center of Physics and Engineering of Advanced Materials, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | - Maria Clara Gonçalves
- Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal; (A.J.); (F.S.C.R.); (M.C.G.)
- CQE, Centro de Química Estrutural, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | - Mónica Faria
- Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa, Portugal; (A.J.); (F.S.C.R.); (M.C.G.)
- CeFEMA, Center of Physics and Engineering of Advanced Materials, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| |
Collapse
|
2
|
Saar-Kovrov V, Zidek W, Orth-Alampour S, Fliser D, Jankowski V, Biessen EAL, Jankowski J. Reduction of protein-bound uraemic toxins in plasma of chronic renal failure patients: A systematic review. J Intern Med 2021; 290:499-526. [PMID: 33792983 DOI: 10.1111/joim.13248] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 12/07/2020] [Accepted: 12/16/2020] [Indexed: 12/23/2022]
Abstract
BACKGROUND Protein-bound uraemic toxins (PBUTs) accumulate in patients with chronic kidney disease and impose detrimental effects on the vascular system. However, a unanimous consensus on the most optimum approach for the reduction of plasma PBUTs is still lacking. METHODS In this systematic review, we aimed to identify the most efficient clinically available plasma PBUT reduction method reported in the literature between 1980 and 2020. The literature was screened for clinical studies describing approaches to reduce the plasma concentration of known uraemic toxins. There were no limits on the number of patients studied or on the duration or design of the studies. RESULTS Out of 1274 identified publications, 101 studies describing therapeutic options aiming at the reduction of PBUTs in CKD patients were included in this review. We stratified the studies by the PBUTs and the duration of the analysis into acute (data from a single procedure) and longitudinal (several treatment interventions) trials. Reduction ratio (RR) was used as the measure of plasma PBUTs lowering efficiency. For indoxyl sulphate and p-cresyl sulphate, the highest RR in the acute studies was demonstrated for fractionated plasma separation, adsorption and dialysis system. In the longitudinal trials, supplementation of haemodialysis patients with AST-120 (Kremezin®) adsorbent showed the highest RR. However, no superior method for the reduction of all types of PBUTs was identified based on the published studies. CONCLUSIONS Our study shows that there is presently no technique universally suitable for optimum reduction of all PBUTs. There is a clear need for further research in this field.
Collapse
Affiliation(s)
- V Saar-Kovrov
- From the, Institute for Molecular Cardiovascular Research IMCAR, University hospital, Aachen, Germany.,Experimental Vascular Pathology Group, Department of Pathology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, the Netherlands
| | - W Zidek
- Department of Nephrology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - S Orth-Alampour
- From the, Institute for Molecular Cardiovascular Research IMCAR, University hospital, Aachen, Germany
| | - D Fliser
- From the, Institute for Molecular Cardiovascular Research IMCAR, University hospital, Aachen, Germany.,Department of Internal Medicine IV - Nephrology and Hypertension, Saarland University Medical Center, Homburg, Germany
| | - V Jankowski
- From the, Institute for Molecular Cardiovascular Research IMCAR, University hospital, Aachen, Germany
| | - E A L Biessen
- From the, Institute for Molecular Cardiovascular Research IMCAR, University hospital, Aachen, Germany.,Experimental Vascular Pathology Group, Department of Pathology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, the Netherlands
| | - J Jankowski
- From the, Institute for Molecular Cardiovascular Research IMCAR, University hospital, Aachen, Germany.,Department of Nephrology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
3
|
He T, Pejchinovski M, Mullen W, Beige J, Mischak H, Jankowski V. Peptides in Plasma, Urine, and Dialysate: Toward Unravelling Renal Peptide Handling. Proteomics Clin Appl 2020; 15:e2000029. [PMID: 32618437 DOI: 10.1002/prca.202000029] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 06/11/2020] [Indexed: 12/28/2022]
Abstract
PURPOSE The peptidomes of spent hemodialysate, urine, and plasma are investigated, to shed light on peptide handling in the kidney. EXPERIMENTAL DESIGN Fifteen plasma, 15 urine, and 13 spent hemodialysate samples are collected from age- and sex-matched subjects with chronic kidney disease. Peptide identification and quantification are performed with capillary electrophoresis-coupled mass spectrometry. RESULTS A total of 6278 urinary peptides, 1743 plasma peptides, and 1727 peptides from spent hemodialysate are detected. Of these, sequences can be assigned to 1580, 419, and 352 peptides, respectively. A strong correlation in peptide abundance between urine and spent hemodialysate (p = 3 × 10-21 , Rho = 0.52), a moderately strong correlation between spent hemodialysate and plasma (p = 4.5 × 10-5 , Rho = 0.30), and no significant correlation between urine and plasma (p = 0.11, Rho = 0.094) are found. Collagen and fibrinogen alpha peptides are highly abundant in all three body fluids. In spent hemodialysate, thymosin ß4 is one of the most abundant peptides, which is shown to be negatively associated with the estimated glomerular filtration rate (Rho = -0.39, p-value = 3.9 × 10-81 ). CONCLUSION AND CLINICAL RELEVANCE The correlation of peptide abundance in these three body fluids is lower than expected, supporting the hypothesis that tubular reabsorption has a major impact on urinary peptide content. Further investigation of thymosin ß4 in hemodialysis is thus warranted.
Collapse
Affiliation(s)
- Tianlin He
- Mosaiques Diagnostics GmbH, Hannover, Germany.,Institute for Molecular Cardiovascular Research (IMCAR), University of Aachen, Aachen, Germany
| | | | - William Mullen
- Institute of Cardiovascular and Medical Science, University of Glasgow, Glasgow, UK
| | - Joachim Beige
- Department of Nephrology and Kuratorium for Dialysis and Transplantation (KfH) Renal Unit, Hospital St. Georg, Leipzig, Germany
| | - Harald Mischak
- Mosaiques Diagnostics GmbH, Hannover, Germany.,Institute of Cardiovascular and Medical Science, University of Glasgow, Glasgow, UK
| | - Vera Jankowski
- Institute for Molecular Cardiovascular Research (IMCAR), University of Aachen, Aachen, Germany
| |
Collapse
|
4
|
Voigt M, Gebert M, Haug U, Hulko M, Storr M, Boschetti-de-Fierro A, Beck W, Krause B. Retention of beneficial molecules and coagulation factors during haemodialysis and haemodiafiltration. Sci Rep 2019; 9:6370. [PMID: 31015539 PMCID: PMC6478905 DOI: 10.1038/s41598-019-42783-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2018] [Accepted: 04/08/2019] [Indexed: 01/08/2023] Open
Abstract
Middle molecules (MMs) are associated with the pathology of uraemia, and are not effectively removed by standard extracorporeal treatments. Increased convection used in haemodiafiltration (HDF) can enhance the removal of MMs; however, high-volume HDF is not available to all patients. The new medium cut-off (MCO) membrane has been developed to allow increased removal of MMs using standard haemodialysis (HD). Improved removal of MMs has been shown with the MCO membrane compared with standard high-flux dialysers, but it is not known whether the increased pore size affects the retention of commonly used medications or that of coagulation factors in dialysis patients. Using an in vitro model, the retention of erythropoietin, heparin, insulin, vancomycin and several coagulation factors (Factors II, VII and X, protein C and antithrombin III) was investigated with the MCO membrane dialyser, compared with high-flux dialysers with polysulfone (in HDF) or polyethersulfone membranes (in HD and HDF). The retention of all molecules investigated was comparable between the MCO membrane and the high-flux dialysers. Results from the in vitro studies suggest that switching from a high-flux dialyser to the MCO membrane should not require changes to the medication dosing or anti-coagulation protocols of dialysis patients.
Collapse
Affiliation(s)
- Manuel Voigt
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| | - Michael Gebert
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| | - Ulrike Haug
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| | - Michael Hulko
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| | - Markus Storr
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| | | | - Werner Beck
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| | - Bernd Krause
- Baxter International Inc., Research & Development, Holger-Crafoord-Str. 26, 72379, Hechingen, Germany
| |
Collapse
|
5
|
Ronci M, Leporini L, Felaco P, Sirolli V, Pieroni L, Greco V, Aceto A, Urbani A, Bonomini M. Proteomic Characterization of a New asymmetric Cellulose Triacetate Membrane for Hemodialysis. Proteomics Clin Appl 2018; 12:e1700140. [PMID: 29808585 DOI: 10.1002/prca.201700140] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Revised: 04/27/2018] [Indexed: 12/24/2022]
Abstract
PURPOSE The artificial membrane inside the haemodialyzer is the main determinant of the quality and success of haemodialysis therapy. The performances of haemodialysis membranes are highly influenced by the interactions with plasma proteins, which in turn are related to the physical and chemical characteristics of the membrane material. The present cross-over study is aimed to analyse the haemodialysis performance of a newly developed asymmetric cellulose triacetate membrane (ATA) in comparison to the conventional parent symmetric polymer (CTA). EXPERIMENTAL DESIGN In four chronic non diabetic haemodialysis patients, the protein constituents of the adsorbed material from the filters after the haemodialysis session, and the proteins recovered in the ultrafiltrate during the session, are identified using a bottom-up shotgun proteomics approach. RESULTS The ATA membrane shows a lower protein adsorption rate and a lower mass distribution pattern of the proteinaceous material. CONCLUSIONS AND CLINICAL RELEVANCE By highlighting the differences between the two haemodialysis filters in terms of adsorbed proteins and flow through, it is demonstrated the higher biocompatibility of the novel ATA membrane, that fulfils the indications for the development of more performant membranes and may represent a step forward for the treatment of patients on chronic haemodialysis.
Collapse
Affiliation(s)
- Maurizio Ronci
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti 66100, Italy.,IRCCS-Santa Lucia Foundation, Rome 00144, Italy
| | - Lidia Leporini
- Department of Pharmacy, University "G. D'Annunzio" of Chieti-Pescara, Chieti 66100, Italy
| | - Paolo Felaco
- Department of Medicine and Aging Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti 66100, Italy
| | - Vittorio Sirolli
- Department of Medicine and Aging Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti 66100, Italy
| | | | | | - Antonio Aceto
- Department of Medical, Oral and Biotechnological Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti 66100, Italy
| | - Andrea Urbani
- IRCCS-Santa Lucia Foundation, Rome 00144, Italy.,Institute of Biochemistry and Clinical Biochemistry, School of Medicine, Catholic University, Rome 00144, Italy
| | - Mario Bonomini
- Department of Medicine and Aging Sciences, University "G. D'Annunzio" of Chieti-Pescara, Chieti 66100, Italy
| |
Collapse
|
6
|
Bonomini M, Pieroni L, Di Liberato L, Sirolli V, Urbani A. Examining hemodialyzer membrane performance using proteomic technologies. Ther Clin Risk Manag 2017; 14:1-9. [PMID: 29296087 PMCID: PMC5739111 DOI: 10.2147/tcrm.s150824] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
The success and the quality of hemodialysis therapy are mainly related to both clearance and biocompatibility properties of the artificial membrane packed in the hemodialyzer. Performance of a membrane is strongly influenced by its interaction with the plasma protein repertoire during the extracorporeal procedure. Recognition that a number of medium-high molecular weight solutes, including proteins and protein-bound molecules, are potentially toxic has prompted the development of more permeable membranes. Such membrane engineering, however, may cause loss of vital proteins, with membrane removal being nonspecific. In addition, plasma proteins can be adsorbed onto the membrane surface upon blood contact during dialysis. Adsorption can contribute to the removal of toxic compounds and governs the biocompatibility of a membrane, since surface-adsorbed proteins may trigger a variety of biologic blood pathways with pathophysiologic consequences. Over the last years, use of proteomic approaches has allowed polypeptide spectrum involved in the process of hemodialysis, a key issue previously hampered by lack of suitable technology, to be assessed in an unbiased manner and in its full complexity. Proteomics has been successfully applied to identify and quantify proteins in complex mixtures such as dialysis outflow fluid and fluid desorbed from dialysis membrane containing adsorbed proteins. The identified proteins can also be characterized by their involvement in metabolic and signaling pathways, molecular networks, and biologic processes through application of bioinformatics tools. Proteomics may thus provide an actual functional definition as to the effect of a membrane material on plasma proteins during hemodialysis. Here, we review the results of proteomic studies on the performance of hemodialysis membranes, as evaluated in terms of solute removal efficiency and blood-membrane interactions. The evidence collected indicates that the information provided by proteomic investigations yields improved molecular and functional knowledge and may lead to the development of more efficient membranes for the potential benefit of the patient.
Collapse
Affiliation(s)
- Mario Bonomini
- Department of Medicine, G. d'Annunzio University, Chieti
| | - Luisa Pieroni
- Proteomic and Metabonomic Units, IRCCS S. Lucia Foundation, Rome
| | | | | | - Andrea Urbani
- Proteomic and Metabonomic Units, IRCCS S. Lucia Foundation, Rome.,Faculty of Medicine, Biochemistry and Clinical Biochemistry Institute, Catholic University of the "Sacred Heart", Rome, Italy
| |
Collapse
|
7
|
Roumelioti ME, Trietley G, Nolin TD, Ng YH, Xu Z, Alaini A, Figueroa R, Unruh ML, Argyropoulos CP. Beta-2 microglobulin clearance in high-flux dialysis and convective dialysis modalities: a meta-analysis of published studies. Nephrol Dial Transplant 2017; 33:1025-1039. [DOI: 10.1093/ndt/gfx311] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Accepted: 10/04/2017] [Indexed: 01/01/2023] Open
Affiliation(s)
- Maria-Eleni Roumelioti
- Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA
| | - Gregory Trietley
- Department of Pharmacy and Therapeutics, Renal-Electrolyte Division, University of Pittsburgh Schools of Pharmacy and Medicine, Pittsburgh, PA, USA
- Department of Medicine, University of Pittsburgh Schools of Pharmacy and Medicine, Pittsburgh, PA, USA
| | - Thomas D Nolin
- Department of Pharmacy and Therapeutics, Renal-Electrolyte Division, University of Pittsburgh Schools of Pharmacy and Medicine, Pittsburgh, PA, USA
- Department of Medicine, University of Pittsburgh Schools of Pharmacy and Medicine, Pittsburgh, PA, USA
| | - Yue-Harn Ng
- Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA
| | - Zhi Xu
- Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA
| | - Ahmed Alaini
- Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA
| | - Rocio Figueroa
- Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA
| | - Mark L Unruh
- Nephrology Division, Department of Medicine, University of New Mexico, Albuquerque, NM, USA
| | | |
Collapse
|
8
|
Meyring-Wösten A, Kuntsevich V, Campos I, Williams S, Ma J, Patel S, Ornillo C, Thijssen S, Kotanko P. Erythrocyte Sodium Sensitivity and Eryptosis in Chronic Hemodialysis Patients. Kidney Blood Press Res 2017; 42:314-326. [DOI: 10.1159/000477608] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Accepted: 03/07/2017] [Indexed: 11/19/2022] Open
|
9
|
Kaleekkal NJ, Rana D, Mohan D. Functionalized MWCNTs in improving the performance and biocompatibility of potential hemodialysis membranes. RSC Adv 2016. [DOI: 10.1039/c6ra09354j] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Functionalized multi-walled carbon nanotube incorporated polyetherimide mixed matrix membranes for blood purification application.
Collapse
Affiliation(s)
- Noel Jacob Kaleekkal
- Membrane Laboratory
- Department of Chemical Engineering
- Anna University
- Chennai-600025
- India
| | - Dipak Rana
- Department of Chemical and Biological Engineering
- University of Ottawa
- Ottawa
- Canada
| | - D. Mohan
- Membrane Laboratory
- Department of Chemical Engineering
- Anna University
- Chennai-600025
- India
| |
Collapse
|
10
|
Bonomini M, Sirolli V, Pieroni L, Felaco P, Amoroso L, Urbani A. Proteomic Investigations into Hemodialysis Therapy. Int J Mol Sci 2015; 16:29508-21. [PMID: 26690416 PMCID: PMC4691132 DOI: 10.3390/ijms161226189] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Revised: 11/26/2015] [Accepted: 12/02/2015] [Indexed: 01/07/2023] Open
Abstract
The retention of a number of solutes that may cause adverse biochemical/biological effects, called uremic toxins, characterizes uremic syndrome. Uremia therapy is based on renal replacement therapy, hemodialysis being the most commonly used modality. The membrane contained in the hemodialyzer represents the ultimate determinant of the success and quality of hemodialysis therapy. Membrane's performance can be evaluated in terms of removal efficiency for unwanted solutes and excess fluid, and minimization of negative interactions between the membrane material and blood components that define the membrane's bio(in)compatibility. Given the high concentration of plasma proteins and the complexity of structural functional relationships of this class of molecules, the performance of a membrane is highly influenced by its interaction with the plasma protein repertoire. Proteomic investigations have been increasingly applied to describe the protein uremic milieu, to compare the blood purification efficiency of different dialyzer membranes or different extracorporeal techniques, and to evaluate the adsorption of plasma proteins onto hemodialysis membranes. In this article, we aim to highlight investigations in the hemodialysis setting making use of recent developments in proteomic technologies. Examples are presented of why proteomics may be helpful to nephrology and may possibly affect future directions in renal research.
Collapse
Affiliation(s)
- Mario Bonomini
- Nephrology and Dialysis Institute, Department of Medicine, G. d'Annunzio University, Chieti-Pescara, SS. Annunziata Hospital, Via dei Vestini, 66013 Chieti, Italy.
| | - Vittorio Sirolli
- Nephrology and Dialysis Institute, Department of Medicine, G. d'Annunzio University, Chieti-Pescara, SS. Annunziata Hospital, Via dei Vestini, 66013 Chieti, Italy.
| | - Luisa Pieroni
- Proteomics and Metabonomics Laboratory, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) S. Lucia Foundation, 00179 Rome, Italy.
- Department of Surgery and Experimental Medicine, Tor Vergata University, 00134 Rome, Italy.
| | - Paolo Felaco
- Nephrology and Dialysis Institute, Department of Medicine, G. d'Annunzio University, Chieti-Pescara, SS. Annunziata Hospital, Via dei Vestini, 66013 Chieti, Italy.
| | - Luigi Amoroso
- Nephrology and Dialysis Institute, Department of Medicine, G. d'Annunzio University, Chieti-Pescara, SS. Annunziata Hospital, Via dei Vestini, 66013 Chieti, Italy.
| | - Andrea Urbani
- Proteomics and Metabonomics Laboratory, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) S. Lucia Foundation, 00179 Rome, Italy.
- Department of Surgery and Experimental Medicine, Tor Vergata University, 00134 Rome, Italy.
| |
Collapse
|