1
|
Bajwa T, Attizzani GF, Gada H, Chetcuti SJ, Williams MR, Ahmed M, Petrossian GA, Saybolt MD, Allaqaband SQ, Merhi WM, Stoler RC, Bezerra H, Mahoney P, Wu W, Jumper R, Lambrecht L, Tang GHL. Use and performance of the evolut FX transcatheter aortic valve system. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024; 67:1-7. [PMID: 38599918 DOI: 10.1016/j.carrev.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 03/22/2024] [Accepted: 04/02/2024] [Indexed: 04/12/2024]
Abstract
BACKGROUND The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.
Collapse
Affiliation(s)
- Tanvir Bajwa
- Advocate Aurora Health Care, 2801 W. Kinnickinnic River Parkway,Milwaukee, WI 53215, United States of America.
| | - Guilherme F Attizzani
- University Hospitals Cleveland Medical Center, 11100 Euclid Avenue, Cleveland, OH 44106, United States of America.
| | - Hemal Gada
- University of Pittsburgh-Pinnacle, 1000 N Front Street, Wormleysburg, PA 17043, United States of America
| | - Stanley J Chetcuti
- University of Michigan, 1500 E Medical Center Drive, Ann Arbor, MI 48109, United States of America.
| | - Mathew R Williams
- New York University - Langone Health, 530 1st Ave. Suite 9V, New York, NY 10016, United States of America.
| | - Mustafa Ahmed
- University of Alabama Medicine, 2000 6th Avenue South, Floor 4, Birmingham, AL 35233, United States of America.
| | - George A Petrossian
- Saint Francis Hospital, Vizza Pavilion, 100 Port Washington Blvd Ste G04, Roslyn, NY 11576, United States of America
| | - Matthew D Saybolt
- Jersey Shore University Medical Center, 1945 NJ-33, Neptune Township, NJ 07753, United States of America
| | - Suhail Q Allaqaband
- Advocate Aurora Health Care, 2801 W. Kinnickinnic River Parkway,Milwaukee, WI 53215, United States of America.
| | - William M Merhi
- Spectrum Health Hospitals, 743 E Beltline Ave NE, Grand Rapids, MI 49525, United States of America.
| | - Robert C Stoler
- Baylor Scott & White Heart and Vascular Hospital at Baylor Scott & White University Medical Center, 621 N Hall St #500, Dallas, TX 75226, United States of America.
| | - Hiram Bezerra
- Tampa General Hospital, University of South Florida; 2 Tampa General Circle, Tampa, FL 33606, United States of America.
| | - Paul Mahoney
- Sentara Norfolk General Hospital, 600 Gresham Dr Ste 8630A, Norfolk, VA 23507, United States of America
| | - Willis Wu
- Rex Hospital, 2800 Blue Ridge Rd Suite 201, Raleigh, NC 27607, United States of America.
| | - Robert Jumper
- St. Vincent's Medical Center, 115 Technology Dr UNIT C300, Trumbull, CT 06611, United States of America.
| | - Larry Lambrecht
- Medtronic, 8200 Coral Sea St., Mounds View, MN 55112, United States of America.
| | - Gilbert H L Tang
- Mount Sinai Health System, 1190 5th Ave, New York, NY 10029, United States of America
| |
Collapse
|
2
|
Yamaguchi K, Nakamura T, Kobayashi T, Yoshizaki T, Uematsu M, Horikoshi T, Nakamura K, Sato A. Aortic tortuosity and pacemaker requirement after transcatheter aortic valve replacement: Mediating effects of anatomical variations. J Cardiol 2024:S0914-5087(24)00172-2. [PMID: 39244023 DOI: 10.1016/j.jjcc.2024.08.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 07/26/2024] [Accepted: 08/22/2024] [Indexed: 09/09/2024]
Affiliation(s)
- Kazuyuki Yamaguchi
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| | - Takamitsu Nakamura
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan.
| | - Tsuyoshi Kobayashi
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| | - Toru Yoshizaki
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| | - Manabu Uematsu
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| | - Takeo Horikoshi
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| | - Kazuto Nakamura
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| | - Akira Sato
- Department of Cardiovascular Medicine, University of Yamanashi, Faculty of Medicine, Chuo, Japan
| |
Collapse
|
3
|
Eckel C, Kim WK, Wasif B, Grothusen C, Elsässer A, Dohmen G, Charitos EI, Sossalla S, Möllmann H, Blumenstein J. Outcomes of transfemoral TAVR using two new-generation devices in patients with horizontal aorta. Catheter Cardiovasc Interv 2024. [PMID: 38860614 DOI: 10.1002/ccd.31094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/10/2024] [Accepted: 05/15/2024] [Indexed: 06/12/2024]
Abstract
BACKGROUND Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic angle (AA) has an impact on procedural outcomes. Matched comparative outcome data of new generation transcatheter heart valves (THVs) in horizontal aorta (HA) are scarce. METHODS A total of 1582 patients with severe native aortic stenosis (AS) treated with the SAPIEN3 Ultra (Ultra; n = 526) or ACURATE Neo2 (Neo2; n = 1056) THVs from January 2017 to January 2023 were analyzed. Patients with non-horizontal aortas (AA < 51.7°, n = 841) were excluded. The population was matched by 1-to-1 nearest-neighbor matching (Ultra, n = 246; Neo2, n = 246). Clinical and procedural outcome were evaluated according to VARC-3 recommendations. RESULTS Technical success (93.1% vs. 94.7%, p = 0.572) was high after Ultra and Neo2. Device success (80.5% vs. 89.8%, p = 0.05) was inferior with Ultra. Neo2 reveals superior hemodynamic properties with lower rate of severe prosthesis patient mismatch (12.0% vs. 3.7%, p = 0.001) and elevated gradients (≥ $\ge $ 20 mmHg: 11.9% vs. 1.7%, p < 0.001). Ultra showed a lower rate of relevant paravalvular regurgitation (> $\gt $ mild paravalvular regurgitation or Valve-in-Valve due to paravalvular regurgitation: 0.0% vs. 3.7%, p = 0.004). The rate of procedural bailout maneuvers (0.8% vs. 0.4%, p = 1.000) and thirty-day all-cause mortality (1.3% vs. 2.2%, p = 0.496) was similar. CONCLUSION Transfemoral TAVR in patients with severe aortic stenosis and HA, using the balloon expandable Sapien3 Ultra and self-expanding ACURATE Neo2 prosthesis, is feasible and safe. Therefore, valve selection between these platforms should be made irrespective of the aortic angle by a team experienced with both valves based on their specific advantages. Large, randomized trials in this sub-group of patients would be necessary to compare long term outcomes.
Collapse
Affiliation(s)
- Clemens Eckel
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
- Carl von Ossietzky Universität Oldenburg, School VI, School of Medicine and Health Sciences, Oldenburg, Germany
| | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Botros Wasif
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Christina Grothusen
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
- Department of Cardiac Surgery, University of Kiel, Kiel, Germany
| | - Albrecht Elsässer
- Carl von Ossietzky Universität Oldenburg, School VI, School of Medicine and Health Sciences, Oldenburg, Germany
| | - Guido Dohmen
- Department of Cardiac Surgery, St. Johannes Hospital, Dortmund, Germany
| | | | - Samuel Sossalla
- Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Johannes Blumenstein
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
- Carl von Ossietzky Universität Oldenburg, School VI, School of Medicine and Health Sciences, Oldenburg, Germany
| |
Collapse
|
4
|
Gorla R, Oliva OA, Arzuffi L, Milani V, Saitta S, Squillace M, Poletti E, Tusa M, Votta E, Brambilla N, Testa L, Bedogni F, Sturla F. Angulation and curvature of aortic landing zone affect implantation depth in transcatheter aortic valve implantation. Sci Rep 2024; 14:10409. [PMID: 38710782 DOI: 10.1038/s41598-024-61084-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 04/30/2024] [Indexed: 05/08/2024] Open
Abstract
In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.
Collapse
Affiliation(s)
- Riccardo Gorla
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy.
| | - Omar A Oliva
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Luca Arzuffi
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Valentina Milani
- Scientific Directorate, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Simone Saitta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
| | - Mattia Squillace
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Enrico Poletti
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Maurizio Tusa
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Emiliano Votta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
- 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Nedy Brambilla
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Luca Testa
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Francesco Bedogni
- Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, P.Zza Edmondo Malan 2, 20097, San Donato Milanese, Milan, Italy
| | - Francesco Sturla
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy
- 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| |
Collapse
|
5
|
Benenati S, Gallo F, Kim WK, Khokhar AA, Zeus T, Toggweiler S, Galea R, De Marco F, Mangieri A, Regazzoli D, Reimers B, Nombela-Franco L, Barbanti M, Regueiro A, Piva T, Rodes-Cabau J, Porto I, Colombo A, Giannini F, Sticchi A. Comparison of Mid-Term Prognosis in Intermediate-to-Low-Risk Contemporary Population with Guidelines-Oriented Age Cutoff. J Cardiovasc Dev Dis 2024; 11:33. [PMID: 38276659 PMCID: PMC10816002 DOI: 10.3390/jcdd11010033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 01/05/2024] [Accepted: 01/18/2024] [Indexed: 01/27/2024] Open
Abstract
BACKGROUND Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.
Collapse
Affiliation(s)
- Stefano Benenati
- Dipartimento di Medicina Interna e Specialità Mediche (DIMI), University of Genoa, 16126 Genoa, Italy (I.P.)
| | - Francesco Gallo
- Interventional Cardiology, Department of Cardio-Thoracic and Vascular Sciences, Ospedale dell’Angelo, AULSS3 Serenissima, Mestre, 30174 Venezia, Italy
| | - Won-keun Kim
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany;
| | - Arif A. Khokhar
- Cardiology Service, Imperial College Healthcare NHS Trust, London W12 0HS, UK
| | - Tobias Zeus
- Division of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University, 40225 Duesseldorf, Germany
| | - Stefan Toggweiler
- Department of Cardiology, Cantonal Hospital Lucern, 6000 Luzern, Switzerland
| | - Roberto Galea
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland;
| | | | - Antonio Mangieri
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy (D.R.)
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20072 Milan, Italy
| | - Damiano Regazzoli
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy (D.R.)
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20072 Milan, Italy
| | - Bernhard Reimers
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy (D.R.)
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20072 Milan, Italy
| | - Luis Nombela-Franco
- Interventional Cardiology Unit, Hospital Àlvaro Cunqueiro, 36312 Vigo, Spain
| | - Marco Barbanti
- Faculty of Medicine and Surgery, Università degli Studi di Enna “Kore”, 94100 Enna, Italy
| | - Ander Regueiro
- Cardiovascular Institute, Hospital Clinic, Institut D’investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), 08036 Barcelona, Spain
| | - Tommaso Piva
- Interventional Cardiology, Ospedali Riuniti Di Ancona, 60126 Ancona, Italy;
| | - Josep Rodes-Cabau
- Quebec Heart and Lung Institute, Laval University, Quebec City, QC G1V 4G5, Canada
| | - Italo Porto
- Dipartimento di Medicina Interna e Specialità Mediche (DIMI), University of Genoa, 16126 Genoa, Italy (I.P.)
| | - Antonio Colombo
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy (D.R.)
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20072 Milan, Italy
| | - Francesco Giannini
- Interventional Cardiology Unit, IRCCS Ospedale Galeazzi Sant’Ambrogio, 20157 Milan, Italy
| | - Alessandro Sticchi
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, 20089 Milan, Italy (D.R.)
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, 20072 Milan, Italy
- Cardiac Catheterisation Laboratory, Cardiothoracic and Vascular Department, Azienda Ospedaliero Universitaria Pisana, 56124 Pisa, Italy
- Dipartimento di Patologia Chirurgica, University of Pisa, Medica, Molecolare e dell’Area Critica, 56126 Pisa, Italy
| |
Collapse
|
6
|
Costa G, Saia F, Pilgrim T, Abdel-Wahab M, Garot P, Sammartino S, Gandolfo C, Branca L, Latib A, Amat-Santos I, Mylotte D, De Marco F, De Backer O, Nombela Franco L, Akodad M, Ribichini FL, Bedogni F, Mazzapicchi A, Tomii D, Laforgia P, Cannata S, Fiorina C, Scotti A, Fezzi S, Criscione E, Poletti E, Mazzucca M, Lunardi M, Mainardi A, Andreaggi S, Quagliana A, Montarello NJ, Hennessey B, Mon-Noboa M, Meier D, Adamo M, Sgroi C, Reddavid CM, Strazzieri O, Crescenzia Motta S, Frittitta V, Dipietro E, Comis A, Melfa C, Calì M, Laterra G, Thiele H, Webb JG, Sondergaard L, Tamburino C, Barbanti M. One-year clinical outcomes of transcatheter aortic valve implantation with the latest iteration of self-expanding or balloonexpandable devices: insights from the OPERA-TAVI registry. EUROINTERVENTION 2024; 20:95-103. [PMID: 37982161 PMCID: PMC10758986 DOI: 10.4244/eij-d-23-00720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 10/09/2023] [Indexed: 11/21/2023]
Abstract
BACKGROUND Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.
Collapse
Affiliation(s)
- Giuliano Costa
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Francesco Saia
- Cardiovascular Department, Policlinico S. Orsola, University of Bologna, Bologna, Italy
| | - Thomas Pilgrim
- Bern University Hospital, Inselspital, Bern, Switzerland
| | | | - Philippe Garot
- Institut Cardiovasculaire Paris Sud (ICPS), Hôpital Jacques Cartier, Ramsay-Santé, Massy, France
| | - Sofia Sammartino
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Caterina Gandolfo
- Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (ISMETT), Palermo, Italy
| | | | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Ignacio Amat-Santos
- Division of Cardiology, Hospital Clínico Universitario de Valladolid, Valladolid, Spain
| | - Darren Mylotte
- Department of Cardiology, University Hospital, University of Galway, Ireland
| | - Federico De Marco
- Interventional Cardiology Department, IRCSS Centro Cardiologico Monzino, Milan, Italy
| | - Ole De Backer
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Luis Nombela Franco
- Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain
| | - Mariama Akodad
- Institut Cardiovasculaire Paris Sud (ICPS), Hôpital Jacques Cartier, Ramsay-Santé, Massy, France
- Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
| | | | - Francesco Bedogni
- Division of Cardiology, IRCSS Policlinico San Donato, San Donato Milanese, Milan, Italy
| | | | - Daijiro Tomii
- Bern University Hospital, Inselspital, Bern, Switzerland
| | - Pietro Laforgia
- Institut Cardiovasculaire Paris Sud (ICPS), Hôpital Jacques Cartier, Ramsay-Santé, Massy, France
| | - Stefano Cannata
- Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (ISMETT), Palermo, Italy
| | | | - Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Simone Fezzi
- Department of Cardiology, University Hospital, University of Galway, Ireland
| | - Enrico Criscione
- Division of Cardiology, IRCSS Policlinico San Donato, San Donato Milanese, Milan, Italy
| | - Enrico Poletti
- Division of Cardiology, IRCSS Policlinico San Donato, San Donato Milanese, Milan, Italy
| | - Mattia Mazzucca
- Division of Cardiology, IRCSS Policlinico San Donato, San Donato Milanese, Milan, Italy
| | - Mattia Lunardi
- Division of Cardiology, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Andrea Mainardi
- Division of Cardiology, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Stefano Andreaggi
- Division of Cardiology, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Angelo Quagliana
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Nicholas J Montarello
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Breda Hennessey
- Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain
| | - Matias Mon-Noboa
- Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain
| | - David Meier
- Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
| | | | - Carmelo Sgroi
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | | | - Orazio Strazzieri
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | | | - Valentina Frittitta
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Elena Dipietro
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Alessandro Comis
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Chiara Melfa
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | - Mariachiara Calì
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | | | - Holger Thiele
- Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - John G Webb
- Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
| | - Lars Sondergaard
- The Heart Center, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
- Abbott Vascular, Santa Clara, CA, USA
| | - Corrado Tamburino
- Division of Cardiology, A.O.U. Policlinico "G. Rodolico-San Marco", Catania, Italy
| | | |
Collapse
|
7
|
Yamaguchi K, Nakamura T, Kobayashi T, Yoshizaki T, Nakamura K, Horikoshi T, Uematsu M, Yamada R, Ando R, Watanabe Y, Kuroki K, Sato A. Computed Tomography-Based Novel Aortic Tortuosity Assessment for Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv 2023; 16:3052-3054. [PMID: 37855808 DOI: 10.1016/j.jcin.2023.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 08/30/2023] [Accepted: 09/05/2023] [Indexed: 10/20/2023]
|
8
|
Alperi A, Pascual I, Moris C, Avanzas P. Neo to Neo 2 in horizontal aorta: From "impact" to "no impact" outcomes. Int J Cardiol 2023; 392:131297. [PMID: 37657672 DOI: 10.1016/j.ijcard.2023.131297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 08/27/2023] [Indexed: 09/03/2023]
Affiliation(s)
- Alberto Alperi
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | - Isaac Pascual
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain; Departamento de Medicina, Universidad de Oviedo, Oviedo, Spain
| | - Cesar Moris
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain; Departamento de Medicina, Universidad de Oviedo, Oviedo, Spain
| | - Pablo Avanzas
- Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain; Departamento de Medicina, Universidad de Oviedo, Oviedo, Spain; Centro de Investigación en Red de Enfermedades Cardiovasculares (CIBERCV), Spain.
| |
Collapse
|
9
|
Yao YJ, Zhao ZG, Wang X, Peng Y, Wei JF, He S, Li YJ, He JJ, Zhu ZK, Feng Y, Chen M. Snaring Self-Expanding Devices to Facilitate Transcatheter Aortic Valve Replacement in Patients with Complex Aortic Anatomies. J Clin Med 2023; 12:5067. [PMID: 37568469 PMCID: PMC10420027 DOI: 10.3390/jcm12155067] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 07/14/2023] [Accepted: 07/31/2023] [Indexed: 08/13/2023] Open
Abstract
The snare-assisted technique has been described to facilitate transcatheter aortic valve replacement (TAVR) delivery system advancement in complex aortic anatomies. However, the evidence is limited to case reports. To evaluate the safety profile of the snare-facilitated approach and its impact on self-expanding (SE) TAVR outcomes, we collected consecutive patients who underwent transfemoral SE-TAVR for aortic stenosis, using propensity score matching (PSM) separately in tricuspid and type-0 and type-1 bicuspid aortic valve morphology between the snare and non-snare groups. In 766 patients, despite the snare group having significantly larger annulus angulation and maximal ascending aortic diameter, both groups achieved comparable 30-day device success rates, regardless of first-generation or new-generation valve use. After PSM, the snare group had a significantly lower new permanent pacemaker implantation rate among 193 type-0 patients (3.3% vs. 18.3%, p = 0.01). The ipsilateral group used new-generation valves less frequently (23.0% vs. 75.4%, p < 0.001), but there were no significant inter-group differences in procedure-related events, except for a lower incidence of PVL ≥ mild in the ipsilateral group (14.9% vs. 32.3%, p = 0.01). In conclusion, the snare-assisted technique appears useful in SE-TAVR with angulated aortic root anatomy, and the benefits were comparable between ipsilateral and contralateral snare techniques.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Yuan Feng
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China; (Y.-J.Y.); (Y.P.); (J.-F.W.); (S.H.); (Y.-J.L.); (J.-J.H.); (Z.-K.Z.)
| | - Mao Chen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China; (Y.-J.Y.); (Y.P.); (J.-F.W.); (S.H.); (Y.-J.L.); (J.-J.H.); (Z.-K.Z.)
| |
Collapse
|
10
|
Leone PP, Scotti A, Ho EC, Assafin M, Doolittle J, Chau M, Slipczuk L, Levitus M, Regazzoli D, Mangieri A, Latib A. Prosthesis Tailoring for Patients Undergoing Transcatheter Aortic Valve Implantation. J Clin Med 2023; 12:338. [PMID: 36615141 PMCID: PMC9821207 DOI: 10.3390/jcm12010338] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/28/2022] [Accepted: 12/29/2022] [Indexed: 01/03/2023] Open
Abstract
Transcatheter aortic valve implantation (TAVI) has risen over the past 20 years as a safe and effective alternative to surgical aortic valve replacement for treatment of severe aortic stenosis, and is now a well-established and recommended treatment option in suitable patients irrespective of predicted risk of mortality after surgery. Studies of numerous devices, either newly developed or reiterations of previous prostheses, have been accruing. We hereby review TAVI devices, with a focus on commercially available options, and aim to present a guide for prosthesis tailoring according to patient-related anatomical and clinical factors that may favor particular designs.
Collapse
Affiliation(s)
- Pier Pasquale Leone
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
- Department of Biomedical Sciences, Humanitas University, 20072 Pieve Emanuele, Italy
- Cardio Center, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
- Cardiovascular Research Foundation, New York, NY 10019, USA
| | - Edwin C. Ho
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Manaf Assafin
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - James Doolittle
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Mei Chau
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Leandro Slipczuk
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Matthew Levitus
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Damiano Regazzoli
- Cardio Center, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Antonio Mangieri
- Cardio Center, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy
| | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| |
Collapse
|
11
|
Guedeney P, Collet JP. [How to select the best device using pre-TAVR CT scan]. Ann Cardiol Angeiol (Paris) 2022; 71:407-412. [PMID: 36273953 DOI: 10.1016/j.ancard.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 09/23/2022] [Accepted: 10/03/2022] [Indexed: 06/16/2023]
Abstract
Transcatheter aortic valve replacement or TAVR has become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. Although the role of computed tomography imaging was initially limited to the determination of the optimal vascular approach, it has progressively matured to become the pilar of TAVR work-up while being standardized by consensus conferences. The list of evaluated elements includes aortic annulus diameter, the optimal projection curve, the number of aortic leaflets, the severity and localization of calcifications, coronary ostial height, membranous septum length and aortic angulation. The proper and cautious evaluation of these elements may help evaluating the risk for the main periprocedural complications such as coronary obstruction, annular rupture, permanent pacemaker implantation or procedural failure and selecting the optimal transcatheter heart valve and its size, according to the patient's specific anatomy. In this review, we detail how the evaluation of these parameters may impact the selection of the transcatheter heart valve.
Collapse
Affiliation(s)
- Paul Guedeney
- Sorbonne Université, ACTION study group, UMR_S 1166, Institut de Cardiologie, Pitié Salpêtrière Hospital (AP-HP), 47 boulevard de l'hôpital, 75013, Paris, France
| | - Jean-Philippe Collet
- Sorbonne Université, ACTION study group, UMR_S 1166, Institut de Cardiologie, Pitié Salpêtrière Hospital (AP-HP), 47 boulevard de l'hôpital, 75013, Paris, France.
| |
Collapse
|
12
|
Personalised Treatment in Aortic Stenosis: A Patient-Tailored Transcatheter Aortic Valve Implantation Approach. J Cardiovasc Dev Dis 2022; 9:jcdd9110407. [PMID: 36421942 PMCID: PMC9694505 DOI: 10.3390/jcdd9110407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/13/2022] [Accepted: 11/18/2022] [Indexed: 11/23/2022] Open
Abstract
Transcatheter aortic valve replacement (TAVI) has become a game changer in the management of severe aortic stenosis shifting the concept from inoperable or high-risk patients to intermediate or low surgical-risk individuals. Among devices available nowadays, there is no clear evidence that one device is better than the other or that one device is suitable for all patients. The selection of the optimal TAVI valve for every patient represents a challenging process for clinicians, given a large number of currently available devices. Consequently, understanding the advantages and disadvantages of each valve and personalising the valve selection based on patient-specific clinical and anatomical characteristics is paramount. This review article aims to both analyse the available devices in the presence of specific clinical and anatomic features and offer guidance to select the most suitable valve for a given patient.
Collapse
|
13
|
Dowling C, Gooley R, McCormick L, Rashid HN, Dargan J, Khan F, Firoozi S, Brecker SJ. Patient-Specific Computer Simulation to Predict Conduction Disturbance With Current-Generation Self-Expanding Transcatheter Heart Valves. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2022; 6:100010. [PMID: 37274548 PMCID: PMC10236875 DOI: 10.1016/j.shj.2022.100010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/19/2022] [Accepted: 02/02/2022] [Indexed: 10/18/2022]
Abstract
Background Patient-specific computer simulation may predict the development of conduction disturbance following transcatheter aortic valve replacement (TAVR). Validation of the computer simulations with current-generation devices has not been undertaken. Methods A retrospective study was performed on patients who had undergone TAVR with a current-generation self-expanding transcatheter heart valve (THV). Preprocedural computed tomography imaging was used to create finite element models of the aortic root. Procedural contrast angiography was reviewed, and finite element analysis performed using a matching THV device size and implantation depth. A region of interest corresponding to the atrioventricular bundle and proximal left bundle branch was identified. The percentage of this area (contact pressure index [CPI]) and maximum contact pressure (CPMax) exerted by THV were recorded. Postprocedural electrocardiograms were reviewed, and major conduction disturbance was defined as the development of persistent left bundle branch block or high-degree atrioventricular block. Results A total of 80 patients were included in the study. THVs were 23- to 29-mm Evolut PRO (n = 53) and 34-mm Evolut R (n = 27). Major conduction disturbance occurred in 27 patients (33.8%). CPI (28.3 ± 15.8 vs. 15.6 ± 11.2%; p < 0.001) and CPMax (0.51 ± 0.20 vs. 0.36 ± 0.24 MPa; p = 0.008) were higher in patients who developed major conduction disturbance. CPI (area under the receiver operating characteristic curve [AUC], 0.74; 95% CI, 0.63-0.86; p < 0.001) and CPMax (AUC, 0.69; 95% CI, 0.57-0.81; p = 0.006) demonstrated a discriminatory power to predict the development of major conduction disturbance. Conclusions Patient-specific computer simulation may identify patients at risk for conduction disturbance after TAVR with current-generation self-expanding THVs.
Collapse
Affiliation(s)
- Cameron Dowling
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Robert Gooley
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Liam McCormick
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - Hashrul N. Rashid
- MonashHeart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Melbourne, Australia
| | - James Dargan
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| | - Faisal Khan
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| | - Sami Firoozi
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| | - Stephen J. Brecker
- Cardiovascular Clinical Academic Group, St. George’s, University of London and St. George’s University Hospitals NHS Foundation Trust, London, UK
| |
Collapse
|
14
|
Micro-dislodgement of a self-expanding transcatheter heart valve: Incidence, predictors, and outcomes. Int J Cardiol 2022; 358:77-82. [DOI: 10.1016/j.ijcard.2022.04.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 11/20/2022]
|
15
|
OUP accepted manuscript. Eur Heart J 2022; 43:2729-2750. [DOI: 10.1093/eurheartj/ehac105] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 02/22/2022] [Accepted: 02/01/2022] [Indexed: 11/12/2022] Open
|
16
|
Description of the Step-by-Step Technique With Snare Catheter for TAVR in Horizontal Aorta. JACC Case Rep 2021; 3:1811-1815. [PMID: 34917960 PMCID: PMC8642723 DOI: 10.1016/j.jaccas.2021.09.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 09/08/2021] [Accepted: 09/17/2021] [Indexed: 12/05/2022]
Abstract
The presence of a horizontal aorta in patients treated with transcatheter aortic valve replacement increases the difficulty of the procedure. We present 5 cases with aortic stenosis with a horizontal aorta who underwent transcatheter aortic valve replacement using a self-expanding prostheses, with the objective of describing the techniques used and obtaining success with a snare catheter. (Level of Difficulty: Intermediate.)
Collapse
|