• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4595230)   Today's Articles (9)   Subscriber (49331)
For: Frautschi JR, Eberhart RC, Hubbell JA, Clark BD, Gelfand JA. Alkylation of cellulosic membranes results in reduced complement activation. J Biomater Sci Polym Ed 1996;7:707-14. [PMID: 8639479 DOI: 10.1163/156856296x00471] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Number Cited by Other Article(s)
1
Saini A, Serrano K, Koss K, Unsworth LD. Evaluation of the hemocompatibility and rapid hemostasis of (RADA)4 peptide-based hydrogels. Acta Biomater 2016;31:71-79. [PMID: 26654763 DOI: 10.1016/j.actbio.2015.11.059] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Revised: 11/19/2015] [Accepted: 11/28/2015] [Indexed: 02/08/2023]
2
Zippel R, Hoene A, Walschus U, Jarchow R, Ueberrueck T, Patrzyk M, Schlosser M, Wilhelm L. Digital image analysis for morphometric evaluation of tissue response after implanting alloplastic vascular prostheses. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2006;12:366-75. [PMID: 16984663 DOI: 10.1017/s1431927606060545] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2006] [Accepted: 06/21/2006] [Indexed: 05/11/2023]
3
Ryu KE, Rhim H, Park CW, Chun HJ, Hong SH, Kim YC, Lee YM. Anti-complement effects of anion-substituted poly(vinyl alcohol) membranes. Macromol Res 2004. [DOI: 10.1007/bf03218994] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
4
Kanno M, Kawakami H, Nagaoka S, Kubota S. Biocompatibility of fluorinated polyimide. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2002;60:53-60. [PMID: 11835159 DOI: 10.1002/jbm.1280] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
5
Vert M, Domurado D. Poly(ethylene glycol): protein-repulsive or albumin-compatible? JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2001;11:1307-17. [PMID: 11261873 DOI: 10.1163/156856200744345] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
6
Hunt JA, McLaughlin PJ, Flanagan BF. Techniques to investigate cellular and molecular interactions in the host response to implanted biomaterials. Biomaterials 1997;18:1449-59. [PMID: 9426174 DOI: 10.1016/s0142-9612(97)00091-4] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA