1
|
Markowitz DM, Affel E, Hajnóczky G, Sergott RC. Future applications of fluorescence lifetime imaging ophthalmoscopy in neuro-ophthalmology, neurology, and neurodegenerative conditions. Front Neurol 2025; 16:1493876. [PMID: 40125394 PMCID: PMC11927091 DOI: 10.3389/fneur.2025.1493876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Accepted: 02/07/2025] [Indexed: 03/25/2025] Open
Abstract
Fluorescence lifetime imaging ophthalmoscopy (FLIO) has emerged as an innovative advancement in retinal imaging, with the potential to provide in vivo non-invasive insights into the mitochondrial metabolism of the retina. Traditional retinal imaging, such as optical coherence tomography (OCT) and fundus autofluorescence (FAF) intensity imaging, focus solely on structural changes to the retina. In contrast, FLIO provides data that may reflect retinal fluorophore activity, some of which may indicate mitochondrial metabolism. This review builds upon the existing literature to describe the principles of FLIO and established uses in retinal diseases while introducing the potential for FLIO in neurodegenerative conditions.
Collapse
Affiliation(s)
- Daniel M. Markowitz
- Drexel University College of Medicine, Philadelphia, PA, United States
- William H. Annesley, EyeBrain Center, Vicky and Jack Farber Neuroscience Institute, Thomas Jefferson University, Partnered with Wills Eye Hospital, Philadelphia, PA, United States
| | - Elizabeth Affel
- William H. Annesley, EyeBrain Center, Vicky and Jack Farber Neuroscience Institute, Thomas Jefferson University, Partnered with Wills Eye Hospital, Philadelphia, PA, United States
| | - György Hajnóczky
- MitoCare Center, Department of Pathology, Anatomy and Cell Biology, Thomas Jefferson University, Philadelphia, PA, United States
| | - Robert C. Sergott
- William H. Annesley, EyeBrain Center, Vicky and Jack Farber Neuroscience Institute, Thomas Jefferson University, Partnered with Wills Eye Hospital, Philadelphia, PA, United States
| |
Collapse
|
2
|
Su E, Kesavamoorthy N, Junge JA, Zheng M, Craft CM, Ameri H. Comparison of Retinal Metabolic Activity and Structural Development between rd10 Mice and Normal Mice Using Multiphoton Fluorescence Lifetime Imaging Microscopy. Curr Issues Mol Biol 2024; 46:612-620. [PMID: 38248341 PMCID: PMC10813981 DOI: 10.3390/cimb46010039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/01/2024] [Accepted: 01/04/2024] [Indexed: 01/23/2024] Open
Abstract
Fluorescence lifetime imaging microscopy (FLIM) is a technique that analyzes the metabolic state of tissues based on the spatial distribution of fluorescence lifetimes of certain interacting molecules. We used multiphoton FLIM to study the metabolic state of developing C57BL6/J and rd10 retinas based on the fluorescence lifetimes of free versus bound nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate (NAD(P)H), with free NAD(P)H percentages suggesting increased glycolysis and bound NAD(P)H percentages indicating oxidative phosphorylation. The mice were sacrificed and enucleated at various time points throughout their first 3 months of life. The isolated eyecups were fixed, sectioned using a polyacrylamide gel embedding technique, and then analyzed with FLIM. The results suggested that in both C57BL6/J mice and rd10 mice, oxidative phosphorylation initially decreased and then increased, plateauing over time. This trend, however, was accelerated in rd10 mice, with its turning point occurring at p10 versus the p30 turning point in C57BL6/J mice. There was also a noticeable difference in oxidative phosphorylation rates between the outer and inner retinas in both strains, with greater oxidative phosphorylation present in the latter. A greater understanding of rd10 and WT metabolic changes during retinal development may provide deeper insights into retinal degeneration and facilitate the development of future treatments.
Collapse
Affiliation(s)
- Erin Su
- Department of Ophthalmology, USC Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (E.S.); (N.K.); (C.M.C.)
| | - Niranjana Kesavamoorthy
- Department of Ophthalmology, USC Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (E.S.); (N.K.); (C.M.C.)
| | - Jason A. Junge
- Department of Biological Sciences, David Dornsife College of Letters Arts and Sciences, University of Southern California Dana, Los Angeles, CA 90089, USA;
| | - Mengmei Zheng
- Department of Ophthalmology, USC Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (E.S.); (N.K.); (C.M.C.)
| | - Cheryl Mae Craft
- Department of Ophthalmology, USC Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (E.S.); (N.K.); (C.M.C.)
| | - Hossein Ameri
- Department of Ophthalmology, USC Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (E.S.); (N.K.); (C.M.C.)
| |
Collapse
|
3
|
Cheong KX, Ong CJT, Chandrasekaran PR, Zhao J, Teo KYC, Mathur R. Review of Retinal Imaging Modalities for Hydroxychloroquine Retinopathy. Diagnostics (Basel) 2023; 13:diagnostics13101752. [PMID: 37238236 DOI: 10.3390/diagnostics13101752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/10/2023] [Accepted: 05/11/2023] [Indexed: 05/28/2023] Open
Abstract
This review provides an overview of conventional and novel retinal imaging modalities for hydroxychloroquine (HCQ) retinopathy. HCQ retinopathy is a form of toxic retinopathy resulting from HCQ use for a variety of autoimmune diseases, such as rheumatoid arthritis and systemic lupus erythematosus. Each imaging modality detects a different aspect of HCQ retinopathy and shows a unique complement of structural changes. Conventionally, spectral-domain optical coherence tomography (SD-OCT), which shows loss or attenuation of the outer retina and/or retinal pigment epithelium-Bruch's membrane complex, and fundus autofluorescence (FAF), which shows parafoveal or pericentral abnormalities, are used to assess HCQ retinopathy. Additionally, several variations of OCT (retinal and choroidal thickness measurements, choroidal vascularity index, widefield OCT, en face imaging, minimum intensity analysis, and artificial intelligence techniques) and FAF techniques (quantitative FAF, near-infrared FAF, fluorescence lifetime imaging ophthalmoscopy, and widefield FAF) have been applied to assess HCQ retinopathy. Other novel retinal imaging techniques that are being studied for early detection of HCQ retinopathy include OCT angiography, multicolour imaging, adaptive optics, and retromode imaging, although further testing is required for validation.
Collapse
Affiliation(s)
- Kai Xiong Cheong
- Singapore Eye Research Institute, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore
| | - Charles Jit Teng Ong
- Singapore Eye Research Institute, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore
| | - Priya R Chandrasekaran
- Singapore Eye Research Institute, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore
| | - Jinzhi Zhao
- Singapore Eye Research Institute, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore
| | - Kelvin Yi Chong Teo
- Singapore Eye Research Institute, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore 169857, Singapore
| | - Ranjana Mathur
- Singapore Eye Research Institute, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore 168751, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore 169857, Singapore
| |
Collapse
|
4
|
Hammer M, Simon R, Meller D, Klemm M. Combining fluorescence lifetime with spectral information in fluorescence lifetime imaging ophthalmoscopy (FLIO). BIOMEDICAL OPTICS EXPRESS 2022; 13:5483-5494. [PMID: 36425633 PMCID: PMC9664887 DOI: 10.1364/boe.457946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/05/2022] [Accepted: 04/07/2022] [Indexed: 06/01/2023]
Abstract
Fluorescence lifetime imaging ophthalmoscopy (FLIO) provides information on fluorescence lifetimes in two spectral channels as well as the peak emission wavelength (PEW) of the fluorescence. Here, we combine these measures in an integral three-dimensional lifetime-PEW metric vector and determine a normal range for this vector from measurements in young healthy subjects. While for these control subjects 97 (±8) % (median (interquartile range)) of all para-macular pixels were covered by this normal vector range, it was 67 (±55) % for the elderly healthy, 38 (±43) % for age-related macular degeneration (AMD)-suspect subjects, and only 6 (±4) % for AMD patients. The vectors were significantly different for retinal pigment epithelium (RPE) lesions in AMD patients from that of non-affected tissue (p < 0.001). Lifetime- PEW plots allowed to identify possibly pathologic fundus areas by fluorescence parameters outside a 95% quantile per subject. In a patient follow-up, changes in fluorescence parameters could be traced in the lifetime-PEW metric, showing their change over disease progression.
Collapse
Affiliation(s)
- Martin Hammer
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
- Center for Medical Optics and Photonics, Univ. of Jena, Jena, Germany
| | - Rowena Simon
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Daniel Meller
- Department of Ophthalmology, University Hospital Jena, Jena, Germany
| | - Matthias Klemm
- Institute of Biomedical Engineering and Informatics, Technical Univ. Ilmenau, Ilmenau, Germany
| |
Collapse
|
5
|
Parrulli S, Cozzi M, Airaldi M, Romano F, Viola F, Sarzi‐Puttini P, Staurenghi G, Invernizzi A. Quantitative autofluorescence findings in patients undergoing hydroxychloroquine treatment. Clin Exp Ophthalmol 2022; 50:500-509. [PMID: 35503294 PMCID: PMC9545387 DOI: 10.1111/ceo.14090] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 04/27/2022] [Accepted: 04/29/2022] [Indexed: 11/28/2022]
Abstract
Background Methods Results Conclusions
Collapse
Affiliation(s)
- Salvatore Parrulli
- Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital University of Milan Milan Italy
| | - Mariano Cozzi
- Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital University of Milan Milan Italy
| | - Matteo Airaldi
- Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital University of Milan Milan Italy
| | - Francesco Romano
- Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital University of Milan Milan Italy
| | - Francesco Viola
- Ophthalmological Unit Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico Milan Italy
- Department of Clinical Sciences and Community Health University of Milan Milan Italy
| | | | - Giovanni Staurenghi
- Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital University of Milan Milan Italy
| | - Alessandro Invernizzi
- Eye Clinic, Department of Biomedical and Clinical Science “Luigi Sacco”, Sacco Hospital University of Milan Milan Italy
- The University of Sydney, Save Sight Institute, Discipline of Ophthalmology Sydney Medical School Sydney New South Wales Australia
| |
Collapse
|
6
|
Alexopoulos P, Madu C, Wollstein G, Schuman JS. The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques. Front Med (Lausanne) 2022; 9:891369. [PMID: 35847772 PMCID: PMC9279625 DOI: 10.3389/fmed.2022.891369] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 05/23/2022] [Indexed: 11/22/2022] Open
Abstract
The field of ophthalmic imaging has grown substantially over the last years. Massive improvements in image processing and computer hardware have allowed the emergence of multiple imaging techniques of the eye that can transform patient care. The purpose of this review is to describe the most recent advances in eye imaging and explain how new technologies and imaging methods can be utilized in a clinical setting. The introduction of optical coherence tomography (OCT) was a revolution in eye imaging and has since become the standard of care for a plethora of conditions. Its most recent iterations, OCT angiography, and visible light OCT, as well as imaging modalities, such as fluorescent lifetime imaging ophthalmoscopy, would allow a more thorough evaluation of patients and provide additional information on disease processes. Toward that goal, the application of adaptive optics (AO) and full-field scanning to a variety of eye imaging techniques has further allowed the histologic study of single cells in the retina and anterior segment. Toward the goal of remote eye care and more accessible eye imaging, methods such as handheld OCT devices and imaging through smartphones, have emerged. Finally, incorporating artificial intelligence (AI) in eye images has the potential to become a new milestone for eye imaging while also contributing in social aspects of eye care.
Collapse
Affiliation(s)
- Palaiologos Alexopoulos
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, United States
| | - Chisom Madu
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, United States
| | - Gadi Wollstein
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, United States
- Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, NY, United States
- Center for Neural Science, College of Arts & Science, New York University, New York, NY, United States
| | - Joel S. Schuman
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, United States
- Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, NY, United States
- Center for Neural Science, College of Arts & Science, New York University, New York, NY, United States
- Department of Electrical and Computer Engineering, NYU Tandon School of Engineering, Brooklyn, NY, United States
| |
Collapse
|
7
|
Yusuf IH, Charbel Issa P, Ahn SJ. Novel imaging techniques for hydroxychloroquine retinopathy. Front Med (Lausanne) 2022; 9:1026934. [PMID: 36314000 PMCID: PMC9606779 DOI: 10.3389/fmed.2022.1026934] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 09/26/2022] [Indexed: 11/13/2022] Open
Abstract
Hydroxychloroquine retinopathy is an increasingly recognized cause of iatrogenic, irreversible visual impairment due to the expanding use of hydroxychloroquine in combination with improvements in disease detection following advances in retinal imaging techniques. The prevalence of disease is estimated to be greater than 5% amongst individuals who have used the drug for 5 years or more. In addition to conventional imaging modalities, such as spectral-domain optical coherence tomography (OCT) and fundus autofluorescence (FAF), novel retinal imaging techniques such as en face OCT, OCT angiography, fluorescence lifetime imaging ophthalmoscopy, quantitative autofluorescence, and retromode imaging are capable of detecting structural changes in the retina. These novel retinal imaging techniques have shown promise in detecting earlier disease than is possible with current mainstream imaging modalities. Moreover, these techniques may identify disease progression as well as enabling functional correlation. In the future, these novel imaging techniques may further reduce the risk of visual loss from hydroxychloroquine retinopathy through the earlier detection of pre-clinical disease.
Collapse
Affiliation(s)
- Imran H Yusuf
- Oxford Eye Hospital and Nuffield Department of Clinical Neurosciences, John Radcliffe Hospital, University of Oxford, Oxford, United Kingdom
| | - Peter Charbel Issa
- Oxford Eye Hospital and Nuffield Department of Clinical Neurosciences, John Radcliffe Hospital, University of Oxford, Oxford, United Kingdom
| | - Seong Joon Ahn
- Department of Ophthalmology, Hanyang University Hospital, Hanyang University College of Medicine, Seoul, South Korea
| |
Collapse
|
8
|
Schultz R, Schwanengel L, Klemm M, Meller D, Hammer M. Spectral fundus autofluorescence peak emission wavelength in ageing and AMD. Acta Ophthalmol 2021; 100:e1223-e1231. [PMID: 34850573 DOI: 10.1111/aos.15070] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 10/26/2021] [Accepted: 11/19/2021] [Indexed: 01/18/2023]
Abstract
PURPOSE To investigate the spectral characteristics of fundus autofluorescence (FAF) in AMD patients and controls. METHODS Fundus autofluorescence spectral characteristics was described by the peak emission wavelength (PEW) of the spectra. Peak emission wavelength (PEW) was derived from the ratio of FAF recordings in two spectral channels at 500-560 nm and 560-720 nm by fluorescence lifetime imaging ophthalmoscopy. The ratio of FAF intensity in both channels was related to PEW by a calibration procedure. Peak emission wavelength (PEW) measurements were done in 44 young (mean age: 24.0 ± 3.8 years) and 18 elderly (mean age: 67.5 ± 10.2 years) healthy subjects as well as 63 patients with AMD (mean age: 74.0 ± 7.3 years) in each pixel of a 30° imaging field. The values were averaged over the central area, the inner and the outer ring of the ETDRS grid. RESULTS There was no significant difference between PEW in young and elderly controls. However, PEW was significantly shorter in AMD patients (ETDRS grid centre: 571 ± 26 nm versus 599 ± 17 nm for elderly controls, inner ring: 596 ± 17 nm versus 611 ± 11 nm, outer ring: 602 ± 16 nm versus 614 ± 11 nm). After a mean follow-up time of 50.8 ± 10.8 months, the PEW in the patients decreased significantly by 9 ± 19 nm in the inner ring of the grid. Patients, showing progression to atrophic AMD in the follow up, had significantly (p ≤ 0.018) shorter PEW at baseline than non-progressing patients. CONCLUSIONS Peak emission wavelength (PEW) is related to AMD pathology and might be a diagnostic marker in AMD. Possibly, a short PEW can predict progression to retinal and/or pigment epithelium atrophy.
Collapse
Affiliation(s)
- Rowena Schultz
- Department of Ophthalmology University Hospital Jena Jena Germany
| | | | - Matthias Klemm
- Institute of Biomedical Engineering and Informatics Technical Univ. Ilmenau Ilmenau Germany
| | - Daniel Meller
- Department of Ophthalmology University Hospital Jena Jena Germany
| | - Martin Hammer
- Department of Ophthalmology University Hospital Jena Jena Germany
- Center for Medical Optics and Photonics Univ. of Jena Jena Germany
| |
Collapse
|
9
|
Lincke JB, Dysli C, Jaggi D, Fink R, Wolf S, Zinkernagel MS. The Influence of Cataract on Fluorescence Lifetime Imaging Ophthalmoscopy (FLIO). Transl Vis Sci Technol 2021; 10:33. [PMID: 34004011 PMCID: PMC8088233 DOI: 10.1167/tvst.10.4.33] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To investigate the influence of lens opacifications on fluorescence lifetime imaging ophthalmoscopy (FLIO). Methods Forty-seven eyes of 45 patients were included. Mean fluorescence lifetimes (Tm) were recorded with a fluorescence lifetime imaging ophthalmoscope in a short spectral channel (SSC) and a long spectral channel (LSC). Retinal and lens autofluorescence lifetimes were measured in subjects before and after cataract surgery. Lens opacification was graded using the Lens Opacities Classification System III (LOCS III) classification. Results The retinal Tm decreased significantly after cataract surgery in both spectral channels (SSC: -53%, P < 0.0001; LSC: -26%, P = 0.0041). The lens Tm differed significantly between the crystalline and the artificial lens in both spectral channels (P < 0.0001). The "nuclear opacity" and "nuclear color" score of the LOCS III classification correlated significantly with the mean Tm difference in both spectral channels (P < 0.0001). Conclusions Lens opacification results in significantly longer retinal Tm. Therefore the lens status has to be considered when performing cross-sectional fluorescence lifetime analysis. Cataract-formation and cataract-surgery needs to be considered when conducting longitudinal studies. Grading of nuclear opacity following the LOCS III classification provides an approximate conversion formula for the mean change of lifetimes, which can be helpful in the interpretation of data in patients with lens opacities. Translational Relevance FLIO is significantly influenced by lens opacities. Using a lens opacity grading scheme and measuring fluorescence lifetimes before and after cataract surgery, an approximative conversion formula can be calculated, which enables the comparison of lifetimes after cataract surgery or over the course of time.
Collapse
Affiliation(s)
- Joel-Benjamin Lincke
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Chantal Dysli
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Damian Jaggi
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Rahel Fink
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Sebastian Wolf
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Martin S Zinkernagel
- Department of Ophthalmology, Inselspital, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
10
|
Abdelbaky MSE, El Mamoun TA, Mabrouk FI, Hassan RM. Frequency and risk factors for hydroxychloroquine retinopathy among patients with systemic lupus erythematosus. THE EGYPTIAN JOURNAL OF INTERNAL MEDICINE 2021; 33:18. [PMID: 34121836 PMCID: PMC8184260 DOI: 10.1186/s43162-021-00047-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 04/26/2021] [Indexed: 11/10/2022] Open
Abstract
Background Hydroxychloroquine (HCQ) is an antimalarial drug, recently used in COVID-19 treatment. Also it is considered over many years the cornerstone in treating systemic lupus erythematosus (SLE) in adults and children. The incidence of retinal affection and retinal toxicity from hydroxychloroquine is rare, but even after the HCQ is stopped, loss of vision may not be reversible and may continue to progress. Fundus autofluorescence (FAF) is one of the screening methods recommended by AAO used for the diagnosis of hydroxychloroquine retinopathy. Our aim is to detect early HCQ-induced retinopathy among SLE patients and the risk factors for its development by using fundus autofluorescence. Results In the present study, 11.3% of the studied patients had significant visual field changes upon testing. Of those, 6.3% had abnormal fundus autofluorescence. We found a significant statistical relation between hydroxychloroquine retinopathy and the duration and cumulative dose of hydroxychloroquine therapy (p value = 0.003) and decreased best-corrected visual acuity of both eyes (p value = 0.000). There was no relationship between HCQ retinopathy detected by fundus autofluorescence and daily dose of HCQ/kg, age, sex, and SLEDAI score. Conclusion Frequency of SLE patients who had confirmed HCQ-induced retinopathy was 6.3%. Hydroxychloroquine could be safely used in all SLE patients regardless of age, sex, and SLE activity. Routine ophthalmological assessment is recommended for SLE patients who received HCQ especially for those who received HCQ longer than 7 years. Fundus autofluorescence is a modern objective tool which is specific for the early detection of HCQ retinopathy.
Collapse
Affiliation(s)
| | | | | | - Rasha Mohamad Hassan
- Department of Medicine Division of Rheumatology, Ain Shams University, Cairo, Egypt
| |
Collapse
|
11
|
Schmitz-Valckenberg S, Pfau M, Fleckenstein M, Staurenghi G, Sparrow JR, Bindewald-Wittich A, Spaide RF, Wolf S, Sadda SR, Holz FG. Fundus autofluorescence imaging. Prog Retin Eye Res 2021; 81:100893. [PMID: 32758681 DOI: 10.1016/j.preteyeres.2020.100893] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/20/2020] [Accepted: 07/25/2020] [Indexed: 12/20/2022]
Abstract
Fundus autofluorescence (FAF) imaging is an in vivo imaging method that allows for topographic mapping of naturally or pathologically occurring intrinsic fluorophores of the ocular fundus. The dominant sources are fluorophores accumulating as lipofuscin in lysosomal storage bodies in postmitotic retinal pigment epithelium cells as well as other fluorophores that may occur with disease in the outer retina and subretinal space. Photopigments of the photoreceptor outer segments as well as macular pigment and melanin at the fovea and parafovea may act as filters of the excitation light. FAF imaging has been shown to be useful with regard to understanding of pathophysiological mechanisms, diagnostics, phenotype-genotype correlation, identification of prognostic markers for disease progression, and novel outcome parameters to assess efficacy of interventional strategies in chorio-retinal diseases. More recently, the spectrum of FAF imaging has been expanded with increasing use of green in addition to blue FAF, introduction of spectrally-resolved FAF, near-infrared FAF, quantitative FAF imaging and fluorescence life time imaging (FLIO). This article gives an overview of basic principles, FAF findings in various retinal diseases and an update on recent developments.
Collapse
Affiliation(s)
- Steffen Schmitz-Valckenberg
- Department of Ophthalmology, University of Bonn, Bonn, Germany; John A. Moran Eye Center, University of Utah, Salt Lake City, USA
| | - Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany; Department of Biomedical Data Science, Stanford University, USA
| | | | - Giovanni Staurenghi
- Department of Biomedical and Clinical Science "Luigi Sacco", Luigi Sacco Hospital University of Milan, Italy
| | - Janet R Sparrow
- Departments of Ophthalmology and Pathology and Cell Biology, Columbia University Medical Center, New York, NY, USA
| | - Almut Bindewald-Wittich
- Department of Ophthalmology, University of Bonn, Bonn, Germany; Augenheilkunde Heidenheim MVZ, Heidenheim, Germany
| | - Richard F Spaide
- Vitreous Retina Macula Consultants of New York, New York, NY, USA
| | - Sebastian Wolf
- Department of Ophthalmology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Srinivas R Sadda
- Doheny Eye Institute, David Geffen School of Medicine, University of California, Los Angeles, USA
| | - Frank G Holz
- Department of Ophthalmology, University of Bonn, Bonn, Germany.
| |
Collapse
|
12
|
Sauer L, Vitale AS, Modersitzki NK, Bernstein PS. Fluorescence lifetime imaging ophthalmoscopy: autofluorescence imaging and beyond. Eye (Lond) 2021; 35:93-109. [PMID: 33268846 PMCID: PMC7852552 DOI: 10.1038/s41433-020-01287-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 10/20/2020] [Accepted: 11/04/2020] [Indexed: 12/14/2022] Open
Abstract
Fluorescence lifetime imaging ophthalmoscopy, FLIO, has gained large interest in the scientific community in the recent years. It is a noninvasive imaging modality that has been shown to provide additional information to conventional imaging modalities. The FLIO device is based on a Heidelberg Engineering Spectralis system. Autofluorescence lifetimes are excited at 473 nm and recorded in two spectral wavelength channels, a short spectral channel (SSC, 498-560 nm) and a long spectral channel (LSC, 560-720 nm). Typically, mean autofluorescence lifetimes in a 30° retinal field are investigated. FLIO shows a clear benefit for imaging different retinal diseases. For example, in age-related macular degeneration (AMD), ring patterns of prolonged FLIO lifetimes 1.5-3.0 mm from the fovea can be appreciated. Macular telangiectasia type 2 (MacTel) shows a different pattern, with prolonged FLIO lifetimes within the typical MacTel zone. In Stargardt disease, retinal flecks can be appreciated even before they are visible with other imaging modalities. Early hydroxychloroquine toxicity appears to be detectable with FLIO. This technique has more potential that has yet to be discovered. This review article focuses on current knowledge as well as pitfalls of this technology. It highlights clinical benefits of FLIO imaging in different ophthalmic and systemic diseases, and provides an outlook with perspectives from the authors.
Collapse
Affiliation(s)
- Lydia Sauer
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Alexandra S Vitale
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Natalie K Modersitzki
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA
| | - Paul S Bernstein
- Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA.
| |
Collapse
|
13
|
Browning DJ, Yokogawa N, Greenberg PB, Perlman E. Rethinking the Hydroxychloroquine Dosing and Retinopathy Screening Guidelines. Am J Ophthalmol 2020; 219:101-106. [PMID: 32610049 DOI: 10.1016/j.ajo.2020.06.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 06/20/2020] [Accepted: 06/21/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE To describe the rationale for revising the hydroxychloroquine (HCQ) dosing and screening guidelines and to identify the barriers to more effective guidelines in the future. DESIGN Literature review. METHODS A PubMed query of studies on HCQ dosing and HCQ retinopathy (HCQR) screening was conducted with a selective review of the English language literature. RESULTS Three iterations of the American Academy of Ophthalmology HCQ dosing and HCQR screening guidelines have been published without including prescribing physicians on the writing committees. This may contribute to prescribing physicians' low adherence to the guidelines. As ancillary tests have improved, asymptomatic HCQR is being detected earlier, leading to a higher reported prevalence of HCQR and a drop in the ceiling for safe dosing. These trends put stricter constraints on prescribers and their patients, who may have had well-controlled autoimmune disease on HCQ doses that were previously considered to be below the high-risk threshold for HCQR. Indeed, stopping HCQ at the earliest sign of HCQR should be reconsidered; for cases of early HCQR, dose reduction and more intensive monitoring for retinopathy may strike a more appropriate balance between HCQ risk and benefits. A prospective study using the Diabetic Retinopathy Clinical Research Retina Network with standardized collection of data, HCQ blood levels, centralized grading of ancillary tests, and community and academic ophthalmologists would provide a stronger evidence base for future HCQ guidelines. CONCLUSIONS The HCQ dosing and screening guidelines should be updated and a prospective study of HCQ dosing and HCQR should be initiated with the joint efforts of ophthalmologists and prescribing physicians.
Collapse
|
14
|
Greenstein VC, Lima de Carvalho JR, Parmann R, Amaro-Quireza L, Lee W, Hood DC, Tsang SH, Sparrow JR. Quantitative Fundus Autofluorescence in HCQ Retinopathy. Invest Ophthalmol Vis Sci 2020; 61:41. [PMID: 32976563 PMCID: PMC7521180 DOI: 10.1167/iovs.61.11.41] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Accepted: 07/31/2020] [Indexed: 01/23/2023] Open
Abstract
Purpose To increase our understanding of the mechanisms underlying hydroxychloroquine (HCQ) retinopathy, analyses by quantitative fundus autofluorescence (qAF) and near-infrared fundus autofluorescence (NIR-AF) were compared to results obtained by recommended screening tests. Methods Thirty-one patients (28 females, 3 males) were evaluated with standard automated perimetry and spectral domain optical coherence tomography (SD-OCT); 28 also had multifocal electroretinography (mfERG). Measurement of short-wavelength fundus autofluorescence (SW-AF) by qAF involved the use of an internal fluorescent reference and intensity measurements in eight concentric segments at 7° to 9° eccentricity. For semiquantitative analysis of NIR-AF, intensities were acquired along a vertical axis through the fovea. Results Four of 15 high-dose (total dose >1000 g, daily dose >5.0 mg/kg) patients and one of 16 low-dose (total dose <1000 g, daily dose 4.4 mg/kg) patients were diagnosed with HCQ-associated retinopathy based on abnormal 10-2 visual fields, SD-OCT, and SW-AF imaging. Three of the high-dose patients also had abnormal mfERG results. Of the five patients exhibiting retinopathy, two had qAF color-coded images revealing higher intensities inferior, nasal, and lateral to the fovea. The abnormal visual fields also exhibited superior-inferior differences. Mean NIR-AF gray-level intensities were increased in four high-dose patients with no evidence of retinopathy. In two patients with retinopathy, NIR-AF intensity within the parafovea was below the normal range. One high-dose patient (6.25 mg/kg) had only abnormal mfERG results. Conclusions These findings indicate that screening for HCQ retinopathy should take into consideration superior-inferior differences in susceptibility to HCQ retinopathy.
Collapse
Affiliation(s)
- Vivienne C. Greenstein
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
- Department of Ophthalmology, New York University School of Medicine, New York, New York, United States
| | | | - Rait Parmann
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
| | - Luz Amaro-Quireza
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
| | - Winston Lee
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
| | - Donald C. Hood
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
- Deparment of Psychology, Columbia University, New York, New York, United States
| | - Stephen H. Tsang
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
- Department of Pathology & Cell Biology, Columbia University Medical Center, New York, New York, United States
| | - Janet R. Sparrow
- Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States
- Department of Pathology & Cell Biology, Columbia University Medical Center, New York, New York, United States
| |
Collapse
|
15
|
Reichel C, Berlin A, Radun V, Tarau IS, Hillenkamp J, Kleefeldt N, Sloan KR, Ach T. Quantitative Fundus Autofluorescence in Systemic Chloroquine/Hydroxychloroquine Therapy. Transl Vis Sci Technol 2020; 9:42. [PMID: 32934892 PMCID: PMC7463177 DOI: 10.1167/tvst.9.9.42] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 08/03/2020] [Indexed: 12/27/2022] Open
Abstract
Purpose To investigate the effect of systemic chloroquine/hydroxychloroquine (CQ/HCQ) on outer retinal health using quantitative fundus autofluorescence (QAF) imaging. Methods For this prospective, cross-sectional study, 44 CQ/HCQ patients and 25 age-matched controls underwent multimodal retinal imaging including QAF (488 nm) and spectral-domain optical coherence tomography (SD-OCT) in addition to the recommended CQ/HCQ screening procedures. Custom written FIJI plugins enabled detailed QAF analysis and correlation with retinal thickness and comparison to the healthy controls. Results Out of 44 patients, 29 (mean age 43.5 ± 12.2, range 22–59 years) exposed to CQ/HCQ (mean cumulative dose 724.2 ± 610.4 g, median 608.0 g, range 18.6–2171.0 g) met eligibility criteria. Four of these 29 patients had bull's-eye maculopathy (BEM). Mean QAF values were significantly higher in CQ/HCQ patients than in healthy controls. QAF increase started early after treatment onset, remained high even years after treatment cessation, and was not accompanied by pathologies in the other screening methods, including retinal thicknesses (except in BEM patients). Conclusions QAF might be a useful tool in retinal imaging and in verifying systemic CQ/HCQ intake. The early onset and preserved high levels of QAF parallel findings of CQ deposition in the retina in animal models. Whether QAF can be used as a screening tool to detect early CQ/HCQ related maculopathy is the subject of long-term ongoing studies. Translation Relevance Experimental QAF imaging in systemic CQ/HCQ therapy monitoring might be a useful tool to indicate the drug or its metabolites and to detect metabolic retinal changes.
Collapse
Affiliation(s)
- Clara Reichel
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany
| | - Andreas Berlin
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany
| | - Victoria Radun
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany
| | - Ioana-Sandra Tarau
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany
| | - Jost Hillenkamp
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany
| | - Nikolai Kleefeldt
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany
| | - Kenneth R Sloan
- University of Alabama at Birmingham, Department of Ophthalmology, Birmingham, AL, USA
| | - Thomas Ach
- University Hospital Würzburg, Department of Ophthalmology, Würzburg, Germany.,University Hospital Bonn, Department of Ophthalmology, Bonn, Germany
| |
Collapse
|