1
|
Poeaim N, Hiran-Us S, Tantilertanant Y. Effect of irrigation protocols for post space preparation on the bond of the resin luting agent and post to a hydraulic calcium silicate filled root: An in vitro study. J Prosthet Dent 2025; 133:1039.e1-1039.e8. [PMID: 39922747 DOI: 10.1016/j.prosdent.2025.01.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2024] [Revised: 01/22/2025] [Accepted: 01/24/2025] [Indexed: 02/10/2025]
Abstract
STATEMENT OF PROBLEM The hydraulic calcium silicate-based sealers (HCSSs) used in endodontic treatments have been reported to interfere with the bond of the post to root canal dentin. Post space irrigation plays a significant role in optimizing the bond, but which protocol is effective for cleaning HCSS-smeared intraradicular dentin is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effect of passive ultrasonic irrigation (PUI) as an adjunct to different irrigation protocols, including with ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX), and sodium hypochlorite (NaOCl), and root regions on the push-out bond strength of a self-etch primer-assisted resin luting agent adhered a post to root canal obturated with hydraulic calcium silicate sealer. MATERIAL AND METHODS The palatal root of 60 human maxillary premolars were shaped and obturated with gutta percha and HCSS (iRoot SP). The post space was prepared using a peeso reamer and double taper drill, and the specimens were divided into 6 groups (n=10) according to the following irrigation protocols: distilled water with conventional syringe, distilled water with PUI, 17% EDTA with PUI, 2% CHX with PUI, 17% EDTA + 2.5% NaOCl with PUI, and 17% EDTA + 2% CHX with PUI. Fiber-reinforced posts (DT Light-Post) were cemented with dual-polymerizing resin luting agent with self-etching primer (Panavia V5). Specimens underwent 6000 thermocycles, were sectioned into 3 slices, and were tested for push-out bond strength and failure mode. The 2-way mixed ANOVA, Kruskal-Wallis H, Dunn post hoc, and chi-squared tests were used for statistical analysis (α=.05). RESULTS The PUI/EDTA/NaOCl group exhibited significantly higher push-out bond strength than irrigation with distilled water, whether incorporated with PUI or not (P=.001 and P=.007, respectively). The root region showed no statistical effects on bond strength (P>.05). The irrigation protocol was significantly associated with failure mode (P=.049). CONCLUSIONS PUI with EDTA/NaOCl followed by distilled water improved the bond strength of self-etch primer-assisted resin luting agent and fiber-reinforced post to an HCSS-obturated tooth. Alternative irrigation protocols did not significantly enhance bond strength.
Collapse
Affiliation(s)
- Nuttanun Poeaim
- Graduate student, Graduate operative, Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Sirawut Hiran-Us
- Assistant Professor, Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Yanee Tantilertanant
- Assistant Professor, Oral biology, Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
2
|
Lee SY, Shimada Y, Sadr A, Tabata T, Sato T, Byun JE, Han SH. Polymerization of resin cements by self-curing with or without adhesive treatment. Dent Mater J 2025; 44:129-139. [PMID: 39828352 DOI: 10.4012/dmj.2024-127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
Abstract
The primary aim of this study was to determine whether there is a difference in degree of conversion (DC) between resin cements polymerized with an adhesive and those without an adhesive. The secondary aim was to compare interfacial gap of zirconia restoration when resin cements are self-cured. The DC of resin cement was measured without adhesive treatment continuously for 15 min and at 24 h. The DC was measured again after light-curing or self-curing adhesive treatment. For interfacial gap evaluation, inlay cavities were prepared on extracted third molars. Zirconia restorations were fabricated and cemented with the resin cement. After thermo-cycling, interfacial gap at the restoration-tooth interface was investigated using swept-source optical coherence tomography (SS-OCT) imaging. The DC of resin cement with adhesive treatment differed depending on the adhesive, cement, and polymerization method (p<0.05). Interfacial gap was different depending on the adhesive and cement (p<0.05).
Collapse
Affiliation(s)
- Su Young Lee
- Department of Prosthodontics, Seoul St. Mary's Dental Hospital, College of Medicine, The Catholic University of Korea
| | - Yasushi Shimada
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Alireza Sadr
- Department of Restorative Dentistry, School of Dentistry, University of Washington
| | - Tomoko Tabata
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Takaaki Sato
- Department of Oral Biomedical Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Ji-Eun Byun
- Department of Conservative Dentistry, College of Dentistry, Yonsei University
| | - Seung-Hoon Han
- Department of Conservative Dentistry, St. Vincent Hospital, College of Medicine, The Catholic University of Korea
| |
Collapse
|
3
|
Piyanuluk N, Sanon K, Thongthai P, Sirirangsee P, Botta R, Ngernsutivorakul T, Srimahachota V, Kusumasari C, Asrianti D, Tagami J. Effect of sulfinate salt on bonding and polymerization of adhesive to intracoronally bleached dentin. Sci Rep 2025; 15:2501. [PMID: 39833371 PMCID: PMC11747175 DOI: 10.1038/s41598-025-86659-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2024] [Accepted: 01/13/2025] [Indexed: 01/22/2025] Open
Abstract
To evaluate the effect of sulfinate salt on the bond performance of a two-step self-etch adhesive to an intracoronally bleached pulpal dentin surface. Intracoronally bleached bovine teeth were treated with or without sulfinate salt (sulfinate agent (SA): Clearfil DC activator) before 2-SEA (Clearfil SE Bond 2) application, while unbleached teeth served as the control (n = 5 teeth). Microtensile bond strength (µTBS) using the bonded surface area of 1 mm2 at the crosshead speed of 1 mm/min measurements after 24 h storage and thermocycles (TC), degree of conversion (DC) analyses by Raman spectroscopy (n = 3 teeth), ultrastructure of resin-dentin interface (n = 3 teeth), and intracoronally bleached pulp chamber dentin surface (n = 3 teeth) observations by scanning electron microscopy (SEM) were subsequently performed. Data were analyzed using the one-way ANOVA, Tukey's post-hoc, and paired t-test. SA significantly increased the initial µTBS to bleached pulp chamber dentin surfaces (from 34.7 ± 4.5 to 50.6 ± 5.2 MPa, p < 0.001) and maintained post-TC bond durability (49.5 ± 8.8, p = 0.58). The application of SA also significantly increased DC on bleached pulp chamber dentin (p < 0.001). Interestingly, the highest DC was found in the SA group. SEM analyses revealed no obvious alteration in surface morphology; however, numerous and longer resin tags were observed at the resin-dentin interface in the bleached group, regardless of SA application. SA could improve bond performance together and enhance the polymerization of 2-SEA to intracoronally bleached pulp chamber dentin.
Collapse
Affiliation(s)
- Napatsorn Piyanuluk
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 34 Henri Dunant Road, Pathumwan, Bangkok, 10330, Thailand
| | - Kittisak Sanon
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 34 Henri Dunant Road, Pathumwan, Bangkok, 10330, Thailand.
- Research Unit of Biomimetic and Regenerative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand.
| | - Pasiree Thongthai
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 34 Henri Dunant Road, Pathumwan, Bangkok, 10330, Thailand
- Research Unit of Biomimetic and Regenerative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
- Center of Excellence on Oral Microbiology and Immunology, Faculty of Dentistry, Chulalongkorn University, Bangkok, 10330, Thailand
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Pharsiri Sirirangsee
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Raju Botta
- National Electronics and Computer Technology Center (NECTEC), National Science and Technology Development Agency (NSTDA), Pahonyothin Road, Khlong Nueng, Khlong Luang, Pathumthani, 12120, Thailand
| | - Thitaphat Ngernsutivorakul
- Department of Chemistry, Faculty of Science, Kasetsart University, Lat Yao, Chatuchak, Bangkok, 10900, Thailand
| | - Varinee Srimahachota
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 34 Henri Dunant Road, Pathumwan, Bangkok, 10330, Thailand
| | - Citra Kusumasari
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas of Indonesia, Jakarta, 10430, Indonesia
| | - Dini Asrianti
- Department of Conservative Dentistry, Faculty of Dentistry, Universitas of Indonesia, Jakarta, 10430, Indonesia
| | - Junji Tagami
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, 34 Henri Dunant Road, Pathumwan, Bangkok, 10330, Thailand.
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Bunkyoku, Tokyo, 113-8549, Japan.
| |
Collapse
|
4
|
Fasham T, Attal JP, Gouze H, Abdel-Gawad S, Dursun E, François P. Effects of CAD/CAM restorative materials and thickness on the depth of cure of various light-cured resin composite materials. Dent Mater J 2024; 43:822-834. [PMID: 39414439 DOI: 10.4012/dmj.2024-053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2024]
Abstract
The study assessed the depth of cure (DOC) of different resin composites light-cured through different types of CAD/CAM materials of variable thickness. Three CAD/CAM materials (multilayer zirconia, lithium disilicate glass ceramic, composite) of three thicknesses (2-, 3-, and 4-mm) were prepared and their translucency parameter (TP) were measured. A light-curable and a dual-curable resin cement (Variolink Esthetic LC and DC) and a bulk-fill resin composite with a higher Ivocerin concentration (Tetric PowerFill) were used to mimic luting agents. DOC was assessed via Vickers microhardness testing. Increased thickness of CAD/CAM specimen was associated with decreased DOC. The chemical composition of the resin composites affected their curing performance depending on the light curing mode. Tetric PowerFill presented the greater DOC among the other resin composites. Receiver operating characteristic models of curing status appeared to provide better insight in predicting the DOC of luting agent according to TP than linear regression.
Collapse
Affiliation(s)
- Timothy Fasham
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR 4462), University Paris Cité
- Department of Restorative Dentistry, Bretonneau Hospital (AP-HP)
| | - Jean-Pierre Attal
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR 4462), University Paris Cité
- Department of Restorative Dentistry, Charles Foix Hospital (AP-HP)
| | - Hélène Gouze
- Department of Rheumatology, Ambroise Paré Hospital (AP-HP)
- Center for Research in Epidemiology and Population Health (U1808), Paris Saclay University
| | - Sarah Abdel-Gawad
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR 4462), University Paris Cité
| | - Elisabeth Dursun
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR 4462), University Paris Cité
- Department of Paediatric Dentistry, Henri-Mondor Hospital (AP-HP)
| | - Philippe François
- Innovative Dental Materials and Interfaces Research Unit (URB2i, UR 4462), University Paris Cité
- Department of Restorative Dentistry, Bretonneau Hospital (AP-HP)
| |
Collapse
|
5
|
Ismail HS, Ali AI, Elawsya ME. Influence of curing mode and aging on the bonding performance of universal adhesives in coronal and root dentin. BMC Oral Health 2024; 24:1188. [PMID: 39369181 PMCID: PMC11456248 DOI: 10.1186/s12903-024-04879-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Accepted: 09/06/2024] [Indexed: 10/07/2024] Open
Abstract
BACKGROUND This study aims to evaluate the microtensile bond strength (µTBS) of different resin composite restorations bonded to mid-coronal dentin and proximal root dentin using light-cured, chemical-cured, and dual-cured adhesives immediately and after aging. Nanoleakage and degree of cure were also assessed. METHODS Eighty-four molars were divided into mid-coronal dentin and proximal root dentin. Each group was further subdivided into three subgroups based on the restorative systems used, which involved the utilization of light-cured, chemical-cured, and dual-cured adhesives. Half of the specimens underwent µTBS testing after 24 h, while the other half after aging. Representative specimens were analyzed for nanoleakage. The degree of cure of the tested adhesive systems was also assessed. RESULTS Aging showed a significant negative effect on µTBS results and led to increased nanoleakage (p < 0.001). Furthermore, in all subgroups, the µTBS values of proximal root dentin were lower compared to mid-coronal dentin, except in the aged subgroup for the system utilizing the dual-cured adhesive. The restorative systems with chemical and dual-cured adhesives demonstrated comparable bonding properties. However, the system with the light-cured adhesive exhibited the worst bonding properties after aging when bonded to proximal root dentin and cured at a large distance (p < 0.05). CONCLUSIONS All tested restorative systems were negatively affected by aging, and the regional dentin had variable effects on the bonding properties. Clinicians should exercise caution when using the tested light-cured adhesive in areas where the curing distance exceeds 3 mm.
Collapse
Affiliation(s)
- Hoda Saleh Ismail
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Algomhoria Street, PO Box 35516, Mansoura, Aldakhlia, Egypt.
| | - Ashraf Ibrahim Ali
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Algomhoria Street, PO Box 35516, Mansoura, Aldakhlia, Egypt
| | - Mohamed Elshirbeny Elawsya
- Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Algomhoria Street, PO Box 35516, Mansoura, Aldakhlia, Egypt
| |
Collapse
|
6
|
Josic U, Teti G, Ionescu A, Maravic T, Mazzitelli C, Cokic S, Van Meerbeek B, Falconi M, Brambilla E, Mazzoni A, Breschi L. Cytotoxicity and microbiological behavior of universal resin composite cements. Dent Mater 2024; 40:1515-1523. [PMID: 39054113 DOI: 10.1016/j.dental.2024.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 07/08/2024] [Accepted: 07/22/2024] [Indexed: 07/27/2024]
Abstract
OBJECTIVES To investigate the cytotoxicity on human dental pulp cells (HDPCs) and Streptococcus mutans (S.mutans) biofilm formation on universal resin composite cements (UCs). METHODS Three UCs (RelyX Universal, 3 M Oral Care - RXU; Panavia SA Cement Universal, Kuraray Noritake - PSAU; SoloCem, Coltene - SCM) and one 'gold-standard' multi-step cement (Panavia V5, Kuraray Noritake - PV5) were used following two polymerization protocols (light-cured - LC; self-cured - SC). Cytotoxicity (MTT) tests were performed after 1, 3 and 7 days of direct contact. Carboxy-2',7'-dichlorodihydrofluorescein diacetate was used to detect the release of reactive oxygen species (ROS), and interleukin 6 (IL-6) expression was analyzed by IL-6 proquantum high sensitivity immunoassay. S. mutans biofilms were grown on UCs samples in a bioreactor for 24 h, then adherent viable biomass was assessed using MTT assay. For microbiological procedures, half of UCs samples underwent accelerated aging. Data were statistically analyzed (α = 0.05). RESULTS The highest cytotoxicity was observed for PSAU SC, RXU SC, and PV5 SC at day 1, then for SC RXU after 3 days, and SC PSAU, LC PV5 and SCM after 1-week (p < 0.05). There was no increase in IL-6 expression after 1 day, while it increased depending on the group at 3 and 7 days. The highest ROS expression after 12 h was recorded for PSAU SC, PV5 SC and PV5 LC. Biofilm formation was as follows: RXU > > PSAU = PV5 > SCM, while light-curing systematically decreased biofilm formation (≈-33 %). Aging leveled out differences between UCs and between polymerization protocols. SIGNIFICANCE The choice of cement brand, rather than category, and polymerization protocol influence cell viability and microbiological behavior. Light-curing is beneficial for reducing the harmful pulpal effect that UCs may possess.
Collapse
Affiliation(s)
- Uros Josic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Gabriella Teti
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Andrei Ionescu
- Oral Microbiology and Biomaterials Laboratory, Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Tatjana Maravic
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Stevan Cokic
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven (UZ Leuven), Dentistry, Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & University Hospitals Leuven (UZ Leuven), Dentistry, Leuven, Belgium
| | - Mirella Falconi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Eugenio Brambilla
- Oral Microbiology and Biomaterials Laboratory, Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Annalisa Mazzoni
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Lorenzo Breschi
- Department for Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy.
| |
Collapse
|
7
|
Muto R, Takamizawa T, Shiratsuchi K, Kasahara Y, Suda S, Watanabe H, Latta MA, Miyazaki M. Influence of luting strategies on dentin bond performance of self-adhesive resin luting cement in combination with a universal adhesive. Clin Oral Investig 2024; 28:478. [PMID: 39122868 DOI: 10.1007/s00784-024-05850-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 07/22/2024] [Indexed: 08/12/2024]
Abstract
OBJECTIVES This study aimed to evaluate the dentin bond performance of various resin luting cement (RLC) systems combined with universal adhesives in different luting strategies. MATERIALS AND METHODS Three self-adhesive resin luting cements (SRLCs) were used with universal adhesives as primers. Twelve specimens per group were prepared to measure shear bond strength (SBS) under distinct luting strategies in etch-&-rinse and self-etch modes. Regarding luting strategies, the bonded specimens were categorized into four groups based on tooth primer application and the curing mode of the SRLC paste: (i) with light irradiation of the tooth primer (wL) + dual-cure mode (DC) of the SRLC paste, (ii) wL + self-cure mode (SC) of the SRLC paste, (iii) without light irradiation of the tooth primer (woL) + DC mode of the SRLC paste, and (iv) woL + SC mode of the SRLC paste. Specimens were also subjected to different storage conditions: 24 h in water (baseline condition) and 10,000 cycles of thermal cycling. RESULTS Luting strategy, storage condition, and SRLC system type significantly influenced dentin SBS values in both etching modes. Notably, certain SRLCs exhibited significantly higher dentin SBS when the primer was light-irradiated compared with no primer irradiation. CONCLUSION Most SRLCs demonstrated higher dentin bond strength with light-irradiated primers, suggesting potential enhancement of dentin bond performance via primer light irradiation.
Collapse
Affiliation(s)
- Rei Muto
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.
| | - Koji Shiratsuchi
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Yuta Kasahara
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Shunichi Suda
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Hidehiko Watanabe
- Department of Restorative Dentistry, School of Dentistry, Oregon Health & Science University, Portland, OR, USA
| | - Mark A Latta
- Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| |
Collapse
|
8
|
Lee SY, Shimada Y, Sadr A, Tabata T, Sato T, Byun JE, Han SH. Degree of conversion and interfacial adaptation of touch-cure resin cement polymerized by self-curing or dual-curing with reduced light. Clin Oral Investig 2024; 28:463. [PMID: 39090476 DOI: 10.1007/s00784-024-05858-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Accepted: 07/23/2024] [Indexed: 08/04/2024]
Abstract
OBJECTIVES The first aim of this study was to determine whether there is a difference in degree of conversion (DC) of touch-cure cements polymerized by self-curing with adhesive or dual-curing under reduced light. The second aim was to compare interfacial adaptation of zirconia restoration cemented using touch-cure cements self-cured or dual-cured by reduced light. METHODS The DC of touch-cure resin cements with adhesive was measured continuously using Fourier transform infrared spectrometry. Experimental groups differed depending on touch-cure cement. Each group had three subgroups of polymerization method. For subgroup 1, the DC was measured by self-curing. For subgroups 2 and 3, the DCs were measured by dual-curing with reduced light penetrating 3 mm and 1 mm zirconia blocks, respectively. For interfacial adaptation evaluation, Class I cavity was prepared on an extracted third molar, and zirconia restoration was fabricated. The restoration was cemented using the same cement. Groups and subgroups for interfacial adaptation were the same as those of the DC measurement. After thermo-cycling, interfacial adaptation at the tooth-restoration interface was evaluated using swept-source optical coherence tomography imaging. RESULTS The DC of touch-cure cement differed depending on the measurement time, resin cement, and polymerization method (p < 0.05). Interfacial adaptation was different depending on the resin cement and polymerization method (p < 0.05). CONCLUSION For touch-cure cement, light-curing with higher irradiance presented a higher DC and superior interfacial adaptation than light-curing with lower irradiance or self-curing. CLINICAL RELEVANCE Although some adhesives accelerate the self-curing of touch-cure cement, light-curing for touch-cure cement is necessary for zirconia cementation.
Collapse
Affiliation(s)
- Su Young Lee
- Department of Prosthodontics, Seoul St. Mary's Dental Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 06591, Republic of Korea
| | - Yasushi Shimada
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Alireza Sadr
- Department of Restorative Dentistry, School of Dentistry, University of Washington, 1959 NE Pacific St, B162, Seattle, WA, 98195, USA
| | - Tomoko Tabata
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Takaaki Sato
- Department of Oral Biomedical Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Ji-Eun Byun
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, #50 Yonsei-ro, Seodaemun-gu, Seoul, Korea
| | - Seung-Hoon Han
- Department of Conservative Dentistry, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, 93 Jungbu-daero, Paldal-gu, Suwon, Gyeonggi-do, 16247, South Korea.
| |
Collapse
|
9
|
Dimitriadi M, Petropoulou A, Zinelis S, Eliades G. Degree of conversion of dual-cured composite luting agents: The effect of transition metal-based touch-cure activators. J Dent 2024; 147:105147. [PMID: 38909647 DOI: 10.1016/j.jdent.2024.105147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Revised: 06/18/2024] [Accepted: 06/20/2024] [Indexed: 06/25/2024] Open
Abstract
PURPOSE The aim of the study was (a) to assess the effect of universal adhesives and tooth primers with novel touch-cure activators on the conversion of dual-cured resin composite luting agents (RLAs) polymerized under the self-curing mode, and (b) to investigate the source of the catalytic effect exerted by the activators. MATERIALS AND METHODS The materials selected were the adhesive RLAs Panavia V5/Tooth Primer (PV5/TP5), Variolink Esthetic DC/Adhese Universal DC (VLE/ADC), and the self-adhesive RLAs GCem ONE/AE Primer (GCO/AEP), RelyX Universal/Scotchbond Universal Plus (RXU/SUP) and Panavia SA Universal/Clearfil Universal Bond Quick (PSU/CUQ), the later serving as a control with an aryl-sulfinate activator. Coronal dentin specimens were prepared (n = 5/material), treated with the corresponding primers/adhesives (non-irradiated) and covered with a 100 μm-thick RLA layer (SC+A group). Three specimen series were additionally prepared (n = 3 × 5/material): A self-cured without the primers/adhesives (SC group), a dual-cured (20 s irradiation) with the corresponding primers/adhesives (DC+A group) and a dual-cured without primers/adhesives (DC group). All specimens were stored for 15 min (37 °C/dark/60 %RH). After demolding the degree of C = C conversion (DC%, top RLA surfaces) was measured by ATR-FTIR spectroscopy. The primer/adhesive liquids were further analyzed by ICP-MS and the microbrush tips of ADC by SEM-EDS. RESULTS The touch-cure activators increased the DC% in all self-cured RLAs but failed to reach the values of the corresponding dual-cured RLAs. The effect of the activators in dual-cured specimens was negligible. The ICP-MS analysis showed the presence of V (AEP, TP5, ADC) and Cu (SUP) transitional metals in the activators, with V been located at the free ends of ADC tip bristles. The V activators demonstrated the highest DC% improvement in self-cured specimens. CONCLUSION The new touch-cure activators significantly increased the conversion of the self-cured RLAs. Therefore, this step should be considered as universally applicable and not selective, as currently proposed for the self-adhesive luting agents by the manufacturers.
Collapse
Affiliation(s)
- M Dimitriadi
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon str, 11527, Goudi, Athens, Greece
| | - A Petropoulou
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon str, 11527, Goudi, Athens, Greece
| | - S Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon str, 11527, Goudi, Athens, Greece
| | - G Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon str, 11527, Goudi, Athens, Greece.
| |
Collapse
|
10
|
Abdel-Gawad S, Dursun E, Ceinos R, Le Goff S, Fasham T, Attal JP, Francois P. Touch-cure activation by marketed universal resin luting cements of their associated primer to dentin. J Oral Sci 2024; 66:139-144. [PMID: 38710613 DOI: 10.2334/josnusd.24-0019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2024]
Abstract
PURPOSE The aim of this study was to investigate the dentin shear bond strength (SBS) and bonding interface of three recently developed "universal" resin luting cements based on different modalities. METHODS The dentin SBS and interfacial analysis of three recently launched "universal" resin luting cements, namely, G-Cem One, RelyX Universal and Panavia SA cement universal, were studied. All bonding protocols, including the previous use of their dedicated primer or universal adhesive in touch-cure mode or light-cure mode were performed. Variolink Esthetic LC used in conjunction with Scotchbond Universal Plus was used as a control group. For each group (n = 9), 10 specimens were tested for dentin SBS and two were examined by scanning electron microscopy. SBS were analyzed by two-way ANOVA followed by Dunnett's test. RESULTS SBS values showed that the three "universal" resin luting cements tested exhibit different adhesive behaviors. G-Cem One with its touch-cure activated primer had a greater SBS to dentin (25.5 MPa) than that of the control group (22.1 MPa). CONCLUSION "Universal" resin luting cements have variable efficacy when used in self-curing mode. The touch-curing mode is also of concern but may show high potential for some formulations.
Collapse
Affiliation(s)
- Sarah Abdel-Gawad
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
| | - Elisabeth Dursun
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
- Department of Pediatric Dentistry, Henri Mondor Hospital
| | - Romain Ceinos
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
- Department of Restorative Dentistry, Côte d'Azur University
| | - Stéphane Le Goff
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
| | - Timothy Fasham
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
- Department of Restorative Dentistry, Bretonneau Hospital
| | - Jean-Pierre Attal
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
- Department of Restorative Dentistry, Charles Foix Hospital
| | - Philippe Francois
- Innovative Dental Materials and Interfaces Research Unit (URB2i), Paris Cité University
- Department of Restorative Dentistry, Bretonneau Hospital
| |
Collapse
|
11
|
Benkeser SM, Karlin S, Rohr N. Effect of curing mode of resin composite cements on water sorption, color stability, and biaxial flexural strength. Dent Mater 2024; 40:897-906. [PMID: 38702210 DOI: 10.1016/j.dental.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 03/21/2024] [Accepted: 04/26/2024] [Indexed: 05/06/2024]
Abstract
OBJECTIVES To determine whether water sorption and solubility of a recently introduced self-adhesive cement is comparable to two clinically tested resin composite cements after thermal aging, and if this is affected by the curing mode. Whether water sorption is correlated with color difference and biaxial flexural strength was also investigated. METHODS Water sorption and solubility of three resin composite cements {RelyX Universal (RUV), (Panavia V5 (PV5), Panavia SA plus (PSA)} were measured after thermal aging. Disk-shaped specimens were either light-cured or autopolymerized (n = 15 per group). Color difference ΔE00 and biaxial flexural strength were also obtained. RESULTS Sorption was highest for RUV (auto: 54.9 ± 9.0 µg/mm3, light: 49.7 ± 4.9 µg/mm3), followed by PSA (auto: 37.7 ± 1.4 µg/mm3, light: 34.5 ± 1.1 µg/mm3) and PV5 (auto: 21.7 ± 0.7 µg/mm3, light: 22.1 ± 0.4 µg/mm3). Light-curing reduced solubility values, particularly for RUV (from 60.7 ± 20.8 µg/mm3 to 6.4 ± 0.8 µg/mm3). Color differences of ΔE00 > 1.8 (considered clinically not acceptable) were noted after aging for RUV and PSA. Sorption and ΔE00 values after aging were correlated linearly (R2 = 0.970). Biaxial flexural strength values were highest for PV5 (light: 153.4 ± 15.9 MPa; auto: 133.2 ± 18.0 MPa) and lowest for RUV (light: 99.3 ± 12.8 MPa; auto: 35.1 ± 8.3 MPa). SIGNIFICANCE Light-curing has beneficial effects on sorption, color stability, and biaxial flexural strength of resin composite cements. Cements containing 2-hydroxymethacrylate such as RUV and PSA are more prone to water sorption and color changes.
Collapse
Affiliation(s)
- Svenja M Benkeser
- Biomaterials and Technology, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland
| | - Sabrina Karlin
- Biomaterials and Technology, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland
| | - Nadja Rohr
- Biomaterials and Technology, Clinic for Reconstructive Dentistry, University Center for Dental Medicine Basel, Basel, Switzerland.
| |
Collapse
|
12
|
Takamizawa T, Aoki R, Hayashi K, Shoji M, Kasahara Y, Barkmeier WW, Latta MA, Kamimoto A, Miyazaki M. Scanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements. Dent Mater J 2024; 43:179-190. [PMID: 38246629 DOI: 10.4012/dmj.2023-219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Abstract
This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.
Collapse
Affiliation(s)
| | - Ryota Aoki
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Kana Hayashi
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Mone Shoji
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Yuta Kasahara
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Wayne W Barkmeier
- Department of General Dentistry, Creighton University School of Dentistry
| | - Mark A Latta
- Department of General Dentistry, Creighton University School of Dentistry
| | - Atsushi Kamimoto
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry
| |
Collapse
|
13
|
Watanabe S, Takamizawa T, Hayashi K, Aoki R, Barkmeier WW, Latta MA, Watanabe H, Miyazaki M. Comparing Various Resin Luting Cement Systems in Different Etching Modes Through Bond Durability and Morphological Features. Oper Dent 2024; 49:231-244. [PMID: 38349845 DOI: 10.2341/23-096-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2023] [Indexed: 02/15/2024]
Abstract
OBJECTIVES This study aimed to investigate bond performance of various resin luting cement (RLC) systems on enamel and dentin in different etching modes and to compare the RLC-tooth interface morphology using scanning electron microscopy (SEM). METHODS AND MATERIALS The self-adhesive RLC systems used in combination with universal adhesives were as follows: Scotchbond Universal Adhesive Plus + RelyX Universal (3M Oral Care) and Clearfil Universal Bond Quick ER + SA Luting Multi (Kuraray Noritake Dental). These RLC systems were also used alone as self-adhesive RLC systems without universal adhesives (self-adhesive mode). The conventional RLC systems for comparison materials were as follows: BeautiBond Xtream + ResiCem EX (Shofu) and Tooth Primer + Panavia V5 (Kuraray Noritake Dental). Twelve specimens were prepared for each group to measure shear bond strength (SBS) in different etching modes. A stainless-steel rod was used as a substitute for indirect restorations. Bonded specimens were allocated to baseline (stored for 24 hours) and artificially aged (thermocycling [TC] for 10,000 cycles) groups. Representative treated tooth surfaces and RLC-tooth interfaces were observed using SEM. RESULTS Three-way analysis of variance (ANOVA) revealed that all the factors (etching mode, storage period, and RLC system) had a significant influence on the enamel SBS values (p<0.05). Enamel SBS was significantly higher in etch-&-rinse (ER) mode than in self-etch (SE) mode, regardless of RLC system or storage period. Three-way ANOVA showed that all the factors had a significant influence on the dentin SBS values (p<0.001). Most RLC systems showed significantly higher dentin SBS in SE mode than in ER mode, regardless of storage period. However, the combination with Scotchbond Universal Adhesive Plus and RelyX Universal showed no significant difference in SBS values between etching modes at the baseline and showed a significantly higher SBS value in ER mode than in SE mode after TC. CONCLUSIONS The self-adhesive RLC systems with universal adhesives tended to show higher enamel and dentin bond performance than the self-adhesive RLC systems alone. The morphology of treated tooth surfaces and resin cement-tooth interfaces were dependent on the RLC system and etching mode used. The RLC systems with primer application showed a thin, high-density layer above the intact dentin in both etching modes, suggesting chemical interaction.
Collapse
Affiliation(s)
- S Watanabe
- Satoru Watanabe, DDS, Department of Operative Dentistry, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - T Takamizawa
- *Toshiki Takamizawa, DDS, PhD, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - K Hayashi
- Kana Hayashi, DDS, Department of Operative Dentistry, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - R Aoki
- Ryota Aoki, DDS, Department of Operative Dentistry, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - W W Barkmeier
- Wayne W. Barkmeier, DDS, MS, Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - M A Latta
- Mark A. Latta, DMD, MS, Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - H Watanabe
- Hidehiko Watanabe, DDS, MS, Department of Restorative Dentistry, Oregon Health & Science University, School of Dentistry, Portland, Oregon, USA
| | - M Miyazaki
- Masashi Miyazaki, DDS, PhD, Nihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
14
|
Aoki R, Takamizawa T, Hayashi K, Arai Y, Ishii R, Shoji M, Kamimoto A, Miyazaki M. Influence of different curing modes on the bonding effectiveness of self-adhesive resin luting cements in combination with universal adhesives. Dent Mater 2024; 40:379-385. [PMID: 38176997 DOI: 10.1016/j.dental.2023.12.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 12/19/2023] [Indexed: 01/06/2024]
Abstract
OBJECTIVES This study aimed to investigate the immediate dentin bond performance and bond durability of self-adhesive resin luting cements (RLCs) in combination with universal adhesives in different curing modes. METHODS Two self-adhesive RLCs were used with universal adhesives as primers. They were also used alone as self-adhesive RLCs. Two multiple-step RLC systems were used as comparison materials. To measure the shear bond strength (SBS) in different curing modes, 12 specimens were prepared for each group. Stainless-steel rods were bonded to bovine dentin, and the bonded specimens were assigned to the baseline group (stored for 24 h) and artificially aged group (thermal cycling [TC], 10,000 cycles). After each storage period, the SBS of the bonded specimens was measured. The Knoop hardness number (KHN) of the cured RLCs was measured with or without primer application in different curing modes at 24 h and after 10,000 TC. The representative RLC/dentin interfaces were observed using scanning electron microscopy (SEM). RESULTS Dentin SBS was significantly influenced by the RLC system but not by the curing mode. Self-adhesive RLCs alone showed significantly lower SBS values than self-adhesive RLCs with primer regardless of the curing mode or storage period. The storage period, curing mode, and RLC system significantly influenced the KHN. SIGNIFICANCE The use of universal adhesives as a primer may help enhance the immediate dentin bond performance and bond durability of self-adhesive RLCs.
Collapse
Affiliation(s)
- Ryota Aoki
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan.
| | - Kana Hayashi
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Yuiko Arai
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Mone Shoji
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Atsushi Kamimoto
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8310, Japan
| |
Collapse
|
15
|
Tang T, Suputtamongkol K, Harnirattisai C, Neoh SP, Pongprueksa P. Interfacial fracture toughness of different surface treatments on zirconia-reinforced lithium silicate glass-ceramics. Dent Mater J 2023; 42:835-843. [PMID: 37880135 DOI: 10.4012/dmj.2023-124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
This study investigated the influence of different surface treatments on unfiring or firing zirconia-reinforced lithium silicate (ZLS) glass-ceramics. Celtra Duo and IPS e.max CAD blocks were cut and process following manufacturer protocols. The specimen surface was treated with seven different protocols. Two ceramic blocks with the same surface treatment were bonded with luting agent and prepared for mini-interfacial fracture toughness tests (mini-iFT). The specimens were tested after 1-week storage. The data was statistically analyzed using two-way ANOVA and Dunnett's T3 comparison (α=0.05). The highest mini-iFT of both Celtra Duo unfired and fired was shown in the HF+S group, which was not significantly different from HF+S+UA. For IPS e.max CAD, the mini-iFT was higher in the groups treated with hydrofluoric acid. Additional adhesive after silane application did not significantly improve bonding effectiveness. Therefore, surface treatment with hydrofluoric acid and silane is recommended for both unfiring and firing ZLS glass ceramics.
Collapse
Affiliation(s)
- Tianyu Tang
- Dental Biomaterials Science (International Programme), Faculty of Dentistry, Mahidol University
- School and Hospital of Stomatology, Kunming Medical University
| | | | | | - Siew Peng Neoh
- Department of Orthodontics, Faculty of Dentistry, Mahidol University
| | - Pong Pongprueksa
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University
| |
Collapse
|
16
|
Dimitriadi M, Petropoulou A, Vakou D, Zinelis S, Eliades G. In vitro evaluation of a silane containing self-adhesive resin luting agent. Dent Mater 2023; 39:181-191. [PMID: 36642688 DOI: 10.1016/j.dental.2022.12.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/20/2022] [Accepted: 12/24/2022] [Indexed: 01/15/2023]
Abstract
OBJECTIVES To investigate the setting characteristics, wettability and bonding capacity with a lithium disilicate ceramic of a silane containing self-adhesive resin luting agent (Panavia SA Universal-PU). METHODS The degree of conversion (DC %) and extent of acid neutralization (SY %) of PU were measured on dual- (DC) and self-cured (SC) specimens after 10, 30 and 60 min storage by ATR-FTIR spectroscopy, whereas the presence of silanols was traced by curve-fitting the 60 min spectra, using the silane-free analog (Panavia SA Plus-PS) as a control. The role of a dedicated adhesive (Clearfil Universal Bond Quick-CU) in assisting the early DC % in PU-SC was investigated on 10 min-stored specimens. The water contact angles on polished and HF acid-etched lithium disilicate surfaces (IPS e.max Press), were assessed before and after silanization by unset PU or a silane primer (Ultradent Silane-SL). Finally, the shear strength of PU-DC specimens bonded to the acid-etched ceramic surfaces was determined before and after SL treatment. RESULTS The DC % was higher in DC than SC (PU, PS; all time intervals), in PU-SC than PS-SC (30, 60 min) and in the CU assisted PU-SC group. The SY % was lower in DC than SC (PU, PS) and higher in PS-SC than PU-SC groups. Silanols were found only in unset PU and PU-DC groups. SL treatment provided higher water contact angles on polished and acid-etched ceramic surfaces and higher shear bond strength on acid-etched ceramic surfaces than PU (p < 0.05 for all comparisons). SIGNIFICANCE Although the degree of conversion of the silane containing luting agent was improved in the self-curing mode, especially in the adhesive assisted group, it was still inferior to light-curing. Acid-neutralization and presence of silanols were affected by the setting modes. The use of a silane primer enhanced the hydrophobicity and bond strength of the silane containing luting agent with the etched ceramic substrate.
Collapse
Affiliation(s)
- Maria Dimitriadi
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| | - Aikaterini Petropoulou
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| | - Dimitra Vakou
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece.
| |
Collapse
|
17
|
Leung GKH, Wong AWY, Chu CH, Yu OY. Update on Dental Luting Materials. Dent J (Basel) 2022; 10:208. [PMID: 36354653 PMCID: PMC9689175 DOI: 10.3390/dj10110208] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Revised: 10/24/2022] [Accepted: 11/01/2022] [Indexed: 08/26/2023] Open
Abstract
A dental luting material aids in the retention and stability of indirect restorations on the prepared tooth structure. In dentistry, clinicians are using a wide range of luting materials for the cementation of indirect restorations. Zinc oxide eugenol and non-eugenol cements, zinc phosphate cement, zinc polycarboxylate cement, glass ionomer cement and resin cements are common dental cements used in dentistry. Each luting material or cement possesses unique properties and clinical implications. An ideal luting cement should be biocompatible, insoluble, resistant to thermal and chemical assaults, antibacterial, aesthetic, simple and easy to use. It should have high strength properties under tension, shear and compression to resist stress at the restoration-tooth interface, as well as adequate working and setting times. So far, no luting material possesses all of these properties of an ideal cement. Scientists have been modifying the conventional luting cements to improve the material's clinical performance and developing novel materials for clinical use. To achieve the best clinical outcome, clinicians should update their knowledge and gain a good understanding of the luting materials so that they can make a wise clinical decision on the material selection and obtain an insight into the development of luting cements. Therefore, the objective of this study is to provide a discussion on the physical, chemical, adhesive and aesthetic properties of common luting materials. The clinical indications of these luting materials are suggested based on their properties. In addition, overviews of the modification of the conventional luting materials and the newly developed luting materials are provided.
Collapse
Affiliation(s)
| | | | | | - Ollie Yiru Yu
- Faculty of Dentistry, The University of Hong Kong, Prince Philip Dental Hospital, 34 Hospital Road, Sai Ying Pun, Hong Kong, China
| |
Collapse
|
18
|
Effect of Method of Removing Caries-Affected Dentin on the Bond Strength of Composite Resin to Root Canal Dentin. Healthcare (Basel) 2022; 10:healthcare10112143. [PMID: 36360483 PMCID: PMC9691166 DOI: 10.3390/healthcare10112143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/18/2022] [Accepted: 10/26/2022] [Indexed: 11/17/2022] Open
Abstract
The adhesion of composite resin to caries-affected dentin differs from the adhesion of resin to sound dentin. We evaluated the bond strengths of dual-cure resin composites applied to caries-affected root canal dentin under various clinical conditions and using several caries removal indicators. In the dye stain 1 group, caries were removed to a pale pink stain level using a caries detector. In the dye stain 2 group, caries were removed to a stain-free level using a caries detector. In the probing group, caries were removed to the level of hardness based on probing with a sharp explorer. Additionally, a sound dentin group was used as a control. We compared the resin composite microtensile bond strengths and failure mode distribution among the groups. The bond strengths (MPa) of the probing (64.6 ± 11.9) and the sound dentin (68.7 ± 11.1) groups were significantly higher than those of the dye stain 1 (46.9 ± 7.9) and 2 (47.5 ± 8.4) groups (p < 0.05). The removal of caries-affected dentin using a dentin-hardness-based technique showed higher tensile strength than that using a dye stain technique involving removal to any color level. Thus, the caries removal technique used on root canal dentin affects the bond strength of the resin composite.
Collapse
|
19
|
Mazzitelli C, Maravic T, Josic U, Mancuso E, Generali L, Checchi V, Breschi L, Mazzoni A. Effect of adhesive strategy on resin cement bonding to dentin. J ESTHET RESTOR DENT 2022; 35:501-507. [PMID: 36281586 DOI: 10.1111/jerd.12978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 10/01/2022] [Accepted: 10/04/2022] [Indexed: 10/31/2022]
Abstract
OBJECTIVE The cement bonding strategy and the polymerization mode can influence the prognosis of indirect restorations. The microtensile bond strength (μTBS) and dentin endogenous enzymatic activity of a dual-cure resin cement (PV5) used in combination with two dentin surface conditioners (accelerator-enhancer primer, TP or universal adhesive, UA) were evaluated. MATERIALS AND METHODS PV5 was used to lute composite overlays after dentin treatment with TP or UA. The resin cement was self-cured, SC (1 h at 37 °C) or dual-cured, DC (20 s light-cure followed by 15 min self-cure at 37°C). The μTBS test, fractographic analysis, and the in situ zymography evaluations were performed after 24 h (T0 ) or 1 yr (T12 ) of artificial storage. Data were statistically analyzed (α = 0.05). RESULTS TP/DC obtained the highest adhesive strengths (45 ± 9 and 36.6 ± 8), while UA/SC (17 ± 8 and 11 ± 4) the lowest, both at T0 and T12 , respectively. DC resulted in superior bonding values than the SC, independent of the dentin surface treatment (p < 0.05). The type of adhesive, curing mode and aging influenced the gelatinolytic activity (p < 0.05). CONCLUSIONS The dual-cure resin cement used in combination with its accelerator-enhancer primer showed superior bonding performances with respect to universal adhesive. Dual-curing the resin cement was determinant to enhance bonding capability over time, independent of the adhesive strategy. CLINICAL RELEVANCE Clinicians must be aware to faithfully follow manufacturer's recommendation regarding the adhesive strategy suggested with the resin cement used.
Collapse
Affiliation(s)
- Claudia Mazzitelli
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Tatjana Maravic
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Uros Josic
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Edoardo Mancuso
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences‐Unit of Dentistry and Oral‐Maxillo‐Facial Surgery University of Modena and Reggio Emilia Modena Italy
| | - Vittorio Checchi
- Department of Surgery, Medicine, Dentistry and Morphological Sciences‐Unit of Dentistry and Oral‐Maxillo‐Facial Surgery University of Modena and Reggio Emilia Modena Italy
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| | - Annalisa Mazzoni
- Department of Biomedical and Neuromotor Sciences, DIBINEM University of Bologna Bologna Italy
| |
Collapse
|
20
|
Rohr N, Märtin S, Zitzmann NU, Fischer J. A comprehensive in vitro study on the performance of two different strategies to simplify adhesive bonding. J ESTHET RESTOR DENT 2022; 34:833-842. [PMID: 35305288 PMCID: PMC9543337 DOI: 10.1111/jerd.12903] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 01/29/2022] [Accepted: 03/05/2022] [Indexed: 11/29/2022]
Abstract
Objective The purpose of this study is to compare the bonding performance and mechanical properties of two different resin composite cements using simplified adhesive bonding strategies. Materials and methods Shear bond strength of two resin composite cements (an adhesive cement: Panavia V5 [PV5] and a self‐adhesive cement: RelyX Universal [RUV]) to human enamel, dentin, and a variety of restorative materials (microfilled composite, composite, polymer‐infiltrated ceramic, feldspar ceramic, lithium disilicate and zirconia) was measured. Thermocycle aging was performed with selected material combinations. Results For both cements, the highest shear bond strength to dentin was achieved when using a primer (PV5: 18.0 ± 4.2 MPa, RUV: 18.2 ± 3.3 MPa). Additional etching of dentin reduced bond strength for RUV (12.5 ± 4.9 MPa). On enamel, PV5 achieved the highest bond strength when the primer was used (18.0 ± 3.1 MPa), while for RUV etching of enamel and priming provided best results (21.2 ± 6.6 MPa). Shear bond strength of RUV to restorative materials was superior to PV5. Bonding to resin‐based materials was predominantly observed for RUV. Conclusions While use of RUV with the selective‐etch technique is slightly more labor intensive than PV5, RUV (with its universal primer) displayed a high‐bonding potential to all tested restorative materials, especially to resin. Clinical significance For a strong adhesion to the tooth substrate, PV5 (with its tooth primer) is to be preferred because etching with phosphoric acid is not required. However, when using a wide range of varying restorative materials, RUV with its universal primer seems to be an adequate option.
Collapse
Affiliation(s)
- Nadja Rohr
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Sabrina Märtin
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Nicola U Zitzmann
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| | - Jens Fischer
- Biomaterials and Technology, Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| |
Collapse
|
21
|
Dimitriadi M, Petropoulou A, Masouras K, Zafiropoulou M, Zinelis S, Eliades G. The Effect of Touch-Cure Polymerization on the Conversion and Hardness of Core Build-Up Resin Composites: A Laboratory Study. MATERIALS 2021; 14:ma14206025. [PMID: 34683614 PMCID: PMC8540395 DOI: 10.3390/ma14206025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/06/2021] [Accepted: 10/11/2021] [Indexed: 11/30/2022]
Abstract
To improve the self-curing capacity and interfacial strength with dentine of dual-cured composite materials, touch-cure activators have been introduced. The aim of the study was to evaluate the effect of these activators on the hardness and conversion of dual-cured resin composite core build-up restoratives. The materials tested were Clearfil DC Core Plus (CF) and Gradia Core (GC) with the corresponding adhesives Clearfil S3 Bond Plus (for CF) and G-Premio Bond/G-Premio DCA activator (for GC). Disk-shaped specimens (n = 6/group) were prepared for the following groups: dual-cured, self-cured and self-cured in contact with the adhesive activators at the bottom surface. After a 3-week storage period (dark/dry/37 °C) the Martens hardness (HM) and degree of conversion (DC%) were determined for the previously mentioned groups and the top surfaces of groups in contact with the adhesives. A statistical analysis was performed by a one-way ANOVA and Holm–Sidak test per material and a Pearson’s correlation analysis (HM vs. DC%) at an α = 0.05. The self-cured specimens resulted in significantly lower HM and DC% values from the dual-cured group, as expected. However, in the presence of the adhesives with touch-cure activators, the conversion of the self-cured groups showed insignificant differences in HM and DC% from the dual-cured in both composite materials. The improvements on the bottom composite surfaces in contact with the adhesives did not extend to the entire specimen length. Nevertheless, improved interfacial curing may improve interfacial durability.
Collapse
Affiliation(s)
- Maria Dimitriadi
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 115 27 Athens, Greece; (M.D.); (M.Z.); (S.Z.)
| | - Aikaterini Petropoulou
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, 115 27 Athens, Greece;
| | - Konstantinos Masouras
- Department of Operative Dentistry, School of Dentistry, National and Kapodistrian University of Athens, 115 27 Athens, Greece;
| | - Maria Zafiropoulou
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 115 27 Athens, Greece; (M.D.); (M.Z.); (S.Z.)
| | - Spiros Zinelis
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 115 27 Athens, Greece; (M.D.); (M.Z.); (S.Z.)
| | - George Eliades
- Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 115 27 Athens, Greece; (M.D.); (M.Z.); (S.Z.)
- Correspondence:
| |
Collapse
|