1
|
|
2
|
Unoki T, Serita A, Grap MJ. Automatic Tube Compensation During Weaning From Mechanical Ventilation. Crit Care Nurse 2008. [DOI: 10.4037/ccn2008.28.4.34] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Takeshi Unoki
- Takeshi Unoki is a senior assistant professor in the School of Nursing at St. Luke’s College of Nursing, Tokyo, Japan. He was a postdoctoral fellow in the School of Nursing at Virginia Commonwealth University in Richmond when this article was written
| | - Akimichi Serita
- Akimichi Serita is a staff nurse in an intensive care unit at Tokyo Dental College Ichikawa General Hospital, Ichikawa, Japan
| | - Mary Jo Grap
- Mary Jo Grap is a professor in the School of Nursing at Virginia Commonwealth University in Richmond
| |
Collapse
|
3
|
Campbell AE, Turley A, Wilkes AR, Hall JE. Cricoid yoke: the effect of surface area and applied force on discomfort experienced by conscious volunteers. Eur J Anaesthesiol 2003; 20:52-5. [PMID: 12553388 DOI: 10.1017/s0265021503000097] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE The application of cricoid force is central to techniques that reduce the risk of gastric regurgitation and the subsequent pulmonary aspiration associated with obstetric and emergency anaesthesia. The discomfort associated with cricoid force in awake preoperative patients increases the incidence of coughing, struggling and pain during induction of anaesthesia. This study determined if increasing the surface area of a cricoid yoke reduced the associated discomfort in volunteers. METHODS Fifty volunteers participated in a randomized single-blinded study. The cricoid yoke was positioned using standard anatomical landmarks and forces of 10, 20, 30 and 40 N were applied in a random order for 20s, using two different yoke attachments with surface areas of 3 and 10 cm2. A rest of 30s was allowed between the application of forces. Discomfort was graded by volunteers on a scale from 0 to 10 (0: no discomfort; 10: worse discomfort imaginable). A score of 10 was allocated if the volunteers could not tolerate the applied force for 20s. RESULTS Median scores for the small yoke were always higher than those for the large yoke at each force. There were significant differences between the scores for the small and large yokes at 10 and 20 N (P < 0.001) and 30 N (P = 0.0233), but there was no significant difference at 40 N. CONCLUSIONS The larger yoke was tolerated better by volunteers when clinically relevant cricoid forces were applied.
Collapse
Affiliation(s)
- A E Campbell
- University of Wales College of Medicine, Department of Anaesthetics and Intensive Care Medicine, Cardiff, UK
| | | | | | | |
Collapse
|
4
|
Browne I, Byrne H, Briggs L. Sickle cell disease in pregnancy. Eur J Anaesthesiol 2003; 20:75-6. [PMID: 12553395 DOI: 10.1017/s0265021503240138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
5
|
Gaszyński T, Gaszyński W, Strzelczyk J. General anaesthesia with remifentanil and cisatracurium for a superobese patient. Eur J Anaesthesiol 2003; 20:77-8. [PMID: 12553396 DOI: 10.1017/s0265021503250134] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
6
|
Erhan E, Ugur G, Alper I, Gunusen I, Ozyar B. Tracheal intubation without muscle relaxants: remifentanil or alfentanil in combination with propofol. Eur J Anaesthesiol 2003; 20:37-43. [PMID: 12557834 DOI: 10.1017/s0265021503000073] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE In some situations, the use of muscle relaxants (neuromuscular blocking drugs) are undesirable or contraindicated. We compared intubating conditions without muscle relaxants in premedicated patients receiving either alfentanil 40 microg kg(-1) or remifentanil 2, 3 or 4 microg kg(-1) followed by propofol 2 mg kg(-1). METHODS In a randomized, double-blind study, 80 healthy patients were assigned to one of four groups (n = 20). After intravenous atropine, alfentanil 40 microg kg(-1) or remifentanil 2, 3 or 4 microg kg(-1) were injected over 90 s followed by propofol 2 mg kg(-1). Ninety seconds after administration of the propofol, laryngoscopy and tracheal intubation were attempted. Intubating conditions were assessed as excellent, good or poor on the basis of ease of lung ventilation, jaw relaxation, laryngoscopy, position of the vocal cords, and patient response to intubation and slow inflation of the endotracheal tube cuff. RESULTS Seven patients who received remifentanil 2 microg kg(-1) and one patient who received remifentanil 3 microg kg(-1) could not be intubated at the first attempts. Excellent intubating conditions (jaw relaxed, vocal cords open and no movement in response to tracheal intubation and cuff inflation) were observed in those who received either alfentanil 40 microg kg(-1) (45% of patients) or remifentanil in doses of 2 microg kg(-1) (20%), 3 microg kg(-1) (75%) or 4 microg kg(-1) (95%). Overall, intubating conditions were significantly better (P < 0.05), and the number of patients showing excellent conditions were significantly higher (P < 0.05) in patients who received remifentanil 4 microg kg(-1) compared with those who received alfentanil 40 microg kg(-1) or remifentanil 2 microg kg(-1). No patient needed treatment for hypotension or bradycardia. CONCLUSIONS Remifentanil 4 microg kg(-1) and propofol 2 mg kg(-1) administered in sequence intravenously provided good or excellent conditions for tracheal intubation in all patients without the use of muscle relaxants.
Collapse
Affiliation(s)
- E Erhan
- Ege University, Department of Anaesthesiology and Reanimation, Faculty of Medicine, Izmir, Turkey.
| | | | | | | | | |
Collapse
|
7
|
Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients. Eur J Anaesthesiol 2003. [DOI: 10.1097/00003643-200301000-00002] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
8
|
Brimacombe J, Keller C. Stability of the LMA-ProSeal and standard laryngeal mask airway in different head and neck positions: a randomized crossover study. Eur J Anaesthesiol 2003; 20:65-9. [PMID: 12553391 DOI: 10.1017/s0265021503000127] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE The LMA-ProSeal laryngeal mask airway is a new laryngeal mask airway with a modified cuff and drainage tube. We compared oropharyngeal leak pressure, intracuff pressure and anatomical position (assessed fibreoptically) for the Size 5 LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway in different head-neck positions and using different intracuff inflation volumes. METHODS Thirty paralysed anaesthetized adult male patients were studied. The LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway were inserted into each patient in random order. The oropharyngeal leak pressure, intracuff pressure, and anatomical position of the airway tube and drainage tube (LMA-ProSeal laryngeal mask airway only) were documented in four head and neck positions (neutral first, then flexion, extension and rotation in random order), and at 0-40 mL cuff volumes in the neutral position in 10 mL increments. RESULTS Compared with the neutral position, the oropharyngeal leak pressure for both the LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway was higher in flexion and rotation (all P < or = 0.02), but lower in extension (all P < or = 0.01). Changes in head-neck position did not alter the anatomical position of the airway tube or the drainage tube. The oropharyngeal leak pressure was always higher for the LMA-ProSeal laryngeal mask airway (all P < or = 0.005) and anatomical position better for the classic laryngeal mask airway (all P < or = 0.04). CONCLUSIONS The anatomical position of the LMA-ProSeal and the classic laryngeal mask airway is stable in different head-neck positions, but head-neck flexion and rotation are associated with an increase, and head-neck extension a decrease, in oropharyngeal leak pressure and intracuff pressure. The Size 5 LMA-ProSeal laryngeal mask airway is capable of forming a more effective seal than the Size 5 classic laryngeal mask airway in males.
Collapse
Affiliation(s)
- J Brimacombe
- University of Queensland James Cook University, Department of Anaesthesia and Intensive Care, Cairns Base Hospital, The Esplanade, Australia.
| | | |
Collapse
|
9
|
|
10
|
Kuhlen R, Max M, Dembinski R, Terbeck S, Jürgens E, Rossaint R. Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients. Eur J Anaesthesiol 2003; 20:10-6. [PMID: 12553382 DOI: 10.1017/s0265021503000024] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE Automatic tube compensation has been designed as a new ventilatory mode to compensate for the non-linear resistance of the endotracheal tube. The study investigated the effects of automatic tube compensation compared with breathing through a T-piece or pressure support during a trial of spontaneous breathing used for weaning patients from mechanical ventilation of the lungs. METHODS Twelve patients were studied who were ready for weaning after prolonged mechanical ventilation (10.2 +/- 8.4 days) due to acute respiratory failure. Patients with chronic obstructive pulmonary disease were excluded. Thirty minutes of automatic tube compensation were compared with 30 min periods of 7 cmH2O pressure support and T-piece breathing. Breathing patterns and workload indices were measured at the end of each study period. RESULTS During T-piece breathing, the peak inspiratory flow rate (0.65 +/- 0.20 L s(-1)) and minute ventilation (8.9 +/- 2.7L min(-1)) were lower than during either pressure support (peak inspiratory flow rate 0.81 +/- 0.25 L s(-1) minute ventilation 10.2 +/- 2.3 L min(-1), respectively) or automatic tube compensation (peak inspiratory flow rate 0.75 +/- 0.26L s(-1); minute ventilation 10.8 +/- 2.7 L min(-1)). The pressure-time product as well as patients' work of breathing were comparable during automatic tube compensation (pressure-time product 214.5 +/- 104.6 cmH2O s(-1) min(-1), patient work of breathing 1.1 +/- 0.4 J L(-1)) and T-piece breathing (pressure-time product 208.3 +/- 121.6 cmH2O s(-1) min(-1), patient work of breathing 1.1 +/- 0.4 J L(-1)), whereas pressure support resulted in a significant decrease in workload indices (pressure-time product 121.2 +/- 64.1 cmH2O s(-1) min(-1), patient work of breathing 0.7 +/- 0.4 J L(-1)). CONCLUSIONS In weaning from mechanical lung ventilation, patients' work of breathing during spontaneous breathing trials is clearly reduced by the application of pressure support 7 cmH2O, whereas the workload during automatic tube compensation corresponded closely to the values during trials of breathing through a T-piece.
Collapse
Affiliation(s)
- R Kuhlen
- University of Aachen Medical School, Department of Anesthesiology, Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
11
|
Abstract
This study reports a review of all comparative published studies of adult day case anaesthesia in the English language up to December 2000. Ten databases were searched using appropriate keywords and data were extracted in a standardized fashion. One hundred-and-one published studies were examined. Recovery measurements were grouped as early, intermediate, late, psychomotor and adverse effects. With respect to induction of anaesthesia, propofol was superior to methohexital, etomidate and thiopental, but equal to sevoflurane and desflurane. Desflurane and sevoflurane were both superior to thiopental. There was no detectable difference between sevoflurane and isoflurane. With respect to the maintenance of anaesthesia, isoflurane and halothane were the worst. There were no significant differences between propofol, desflurane, sevoflurane and enflurane. Propofol is the induction agent of choice in day case patients. The use of a propofol infusion and avoidance of nitrous oxide may help to reduce postoperative nausea and vomiting.
Collapse
|
12
|
Abstract
BACKGROUND AND OBJECTIVE Preoperative bedside screening tests for difficult tracheal intubation may be neither sensitive nor specific enough for clinical use. The aim was to investigate if a combination of the Mallampati classification of the oropharyngeal view with either the thyromental or sternomental distance measurement improved the predictive value. METHODS A total of 212 (109 male, 103 female) non-obstetric surgical patients, aged >18 yr, undergoing elective surgical procedures requiring tracheal intubation were assessed preoperatively with respect to the oropharyngeal (modified Mallampati) classification, thyromental and sternomental distances. An experienced anaesthetist, blinded to the preoperative airway assessment, performed laryngoscopy and graded the view according to Cormack and Lehane's classification. RESULTS Twenty tracheal intubations (9%) were difficult as defined by a Cormack and Lehane Grade 3 or 4, or the requirement for a bougie in patients with Cormack and Lehane Grade 2. Used alone, the Mallampati oropharyngeal view, and thyromental and sternomental distances were associated with poor sensitivity, specificity and positive predictive values. Combining the Mallampati Class III or IV with either a thyromental distance <6.5cm or a sternomental distance <12.5cm decreased the sensitivity (from 40 to 25 and 20%, respectively), but maintained a negative predictive value of 93%. The specificity and positive predictive values increased from 89 and 27% respectively for Mallampati alone to 100%. CONCLUSIONS The findings suggest that the Mallampati classification, in conjunction with measurement of the thyromental and sternomental distances, may be a useful routine screening test for preoperative prediction of difficult tracheal intubation.
Collapse
Affiliation(s)
- G Iohom
- Beaumont Hospital, Department of Anaesthesia and Intensive Care, Dublin, Ireland.
| | | | | |
Collapse
|
13
|
Alper I, Erhan E, Ugur G, Ozyar B. Remifentanil versus alfentanil in total intravenous anaesthesia for day case surgery. Eur J Anaesthesiol 2003; 20:61-4. [PMID: 12553390 DOI: 10.1017/s0265021503000115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE We assessed the intraoperative haemodynamic responses and recovery profiles of total intravenous anaesthesia with remifentanil and alfentanil for outpatient surgery. METHODS Patients in Group 1 (n = 20) received alfentanil 20 microg kg(-1) followed by 2 microg kg(-1) min(-1) intravenously; patients in Group 2 (n = 20) received remifentanil 1 microg kg(-1) followed by 0.5 microg kg(-1) min(-1) intravenously. Both groups then received propofol 2 mg kg(-1) followed by 9 mg kg(-1) h(-1) intravenously. Five minutes after skin incision, infusion rates were decreased, and at the end of surgery, all infusions were discontinued. Early recovery was assessed by the Aldrete score, whereas intermediate recovery was assessed with the postanaesthetic discharge scoring system (PADS). RESULTS Perioperative arterial pressure was similar in both groups; heart rate was lower in Group 2 (P < 0.05). The times to spontaneous and adequate respiration, response to verbal commands, extubation and times for Aldrete score > or = 9 were shorter in Group 2 patients (P < 0.05). Pain scores were higher in Group 2 patients (P < 0.05). Overall times for postanaesthetic discharge scores > or = 9 were similar. CONCLUSIONS Early recovery of patients after day surgery is significantly shorter after total intravenous anaesthesia with remifentanil compared with that with alfentanil but postoperative pain management must be planned ahead.
Collapse
Affiliation(s)
- I Alper
- Ege University, Department of Anaesthesiology and Reanimation, Faculty of Medicine, Bornova, Izmir, Turkey.
| | | | | | | |
Collapse
|
14
|
Turhanoğlu S, Kararmaz A, Ozyilmaz MA, Kaya S, Tok D. Effects of different doses of oral ketamine for premedication of children. Eur J Anaesthesiol 2003; 20:56-60. [PMID: 12553389 DOI: 10.1017/s0265021503000103] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE A need exists for a safe and effective oral preanaesthetic medication for use in children undergoing elective surgery. The study sought to define the dose of oral ketamine that would facilitate induction of anaesthesia without causing significant side-effects. METHODS We studied 80 children undergoing elective surgery under general anaesthesia who received oral ketamine 4, 6 or 8 mg kg(-1) in a prospective, randomized, double-blind placebo controlled study. We compared the reaction to separation from parents, transport to the operating room, the response to intravenous cannula insertion and application of an anaesthetic facemask, the induction of anaesthesia and recovery from anaesthesia. RESULTS In the group receiving ketamine 8 mg kg(-1), the children were significantly calmer than those of the other groups, and anaesthesia induction was more comfortable. Recovery from anaesthesia was longer in the group receiving ketamine 8 mg kg(-1) compared with the other groups, but no differences between the groups were observed after 2 h in the recovery room. CONCLUSIONS It is concluded that oral ketamine 8 mg kg(-1) is an effective oral premedication in inpatient children undergoing elective surgery.
Collapse
Affiliation(s)
- S Turhanoğlu
- Dicle University Hospital, Department of Anaesthesiology, Diyarbakir, Turkey.
| | | | | | | | | |
Collapse
|
15
|
Reuter DA, Felbinger TW, Schmidt C, Moerstedt K, Kilger E, Lamm P, Goetz AE. Trendelenburg positioning after cardiac surgery: effects on intrathoracic blood volume index and cardiac performance. Eur J Anaesthesiol 2003; 20:17-20. [PMID: 12553383 DOI: 10.1017/s0265021503000036] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE The efficacy of the Trendelenburg position, a common first step to treat suspected hypovolaemia, remains controversial. We evaluated its haemodynamic effects on cardiac preload and performance in patients after cardiac surgery. METHODS Twelve patients undergoing mechanical ventilation of the lungs who demonstrated left ventricular 'kissing papillary muscles' by transoesophageal echocardiography, thus suggesting hypovolaemia, were positioned 30 degrees head down for 15 min immediately after cardiac surgery. Cardiac output by thermodilution, central venous pressure, pulmonary artery occlusion pressure, left ventricular end-diastolic area by transoesophageal echocardiography and intrathoracic blood volume by thermo- and dye dilution were determined before, during and after this Trendelenburg manoeuvre. RESULTS Trendelenburg's manoeuvre was associated with increases in central venous pressure (9 +/- 2 to 12 +/- 3 mmHg) and pulmonary artery occlusion pressure (8 +/- 2 to 11 +/- 3 mmHg). The intrathoracic blood volume index increased slightly (dye dilution from 836 +/- 129 to 872 +/- 112 mL m(-2); thermodilution from 823 +/- 129 to 850 +/- 131 mL m(-2)) as did the left ventricular end-diastolic area index (7.5 +/- 2.1 to 8.1 +/- 1.7 cm2 m(-2)), whereas mean arterial pressure and the cardiac index did not change significantly. After supine repositioning, the cardiac index decreased significantly below baseline (3.0 +/- 0.6 versus 3.5 +/- 0.8 L min(-1) m(-2)) as did mean arterial pressure (76 +/- 12 versus 85 +/- 11 mmHg), central venous pressure (8 +/- 2 mmHg) and pulmonary artery occlusion pressure (6 +/- 4 mmHg). The intrathoracic blood volume index and left ventricular end-diastolic area index did not differ significantly from baseline. CONCLUSIONS Trendelenburg's manoeuvre caused only a slight increase of preload volume, despite marked increases in cardiac-filling pressures, without significantly improving cardiac performance.
Collapse
Affiliation(s)
- D A Reuter
- Ludwig-Maximilians-University, Department of Anaesthesiology, Munich, Germany
| | | | | | | | | | | | | |
Collapse
|
16
|
Reisli R, Celik J, Tuncer S, Yosunkaya A, Otelcioglu S. Anaesthetic and haemodynamic effects of continuous spinal versus continuous epidural anaesthesia with prilocaine. Eur J Anaesthesiol 2003; 20:26-30. [PMID: 12553385 DOI: 10.1017/s026502150300005x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE To compare, using prilocaine, the effects of continuous spinal anaesthesia (CSA) and continuous epidural anaesthesia (CEA) on haemodynamic stability as well as the quality of anaesthesia and recovery in patients undergoing transurethral resection of the prostate gland. METHODS Thirty patients (>60 yr) were randomized into two groups. Prilocaine, 2% 40 mg, was given to patients in the CSA group, and prilocaine 1% 150mg was given to patients in the CEA group. Incremental doses were given if the level of sensory block was lower than T10 or if needed during surgery. RESULTS There was a significant decrease in mean arterial pressure in Group CEA compared with Group CSA (P < 0.01). The decrease in heart rate in Group CSA occurred 10 min after the first local anaesthetic administration and continued through the operation (P < 0.05). The level of sensory anaesthesia was similar in both groups. The times to reach the level of T10 and the upper level of sensory blockade (Tmax) were 18.0 +/- 4.7 and 25.3 +/- 7.0 min in Groups CSA and CEA, respectively, and were significantly longer in Group CEA. The duration of anaesthesia was 76.8 +/- 4min and was shorter in Group CSA (P < 0.01). CONCLUSIONS Spinal or epidural anaesthesia administered continuously was reliable in elderly patients undergoing transurethral resection of the prostate. Continuous spinal anaesthesia had a more rapid onset of action, produced more effective sensory and motor blockade and had a shorter recovery period. Prilocaine appeared to be a safe local anaesthetic for use with either continuous spinal anaesthesia or continuous epidural anaesthesia.
Collapse
Affiliation(s)
- R Reisli
- University of Selcuk, Faculty of Medicine, Department of Anaesthesiology, Konya, Turkey.
| | | | | | | | | |
Collapse
|
17
|
Raymondos K, Münte S, Krauss T, Grouven U, Piepenbrock S. Cortical activity assessed by Narcotrend in relation to haemodynamic responses to tracheal intubation at different stages of cortical suppression and reflex control. Eur J Anaesthesiol 2003; 20:44-51. [PMID: 12553387 DOI: 10.1017/s0265021503000085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE Many anaesthesiologists still interpret haemodynamic responses as signs of insufficient cortical suppression. The aim was to illustrate how haemodynamics may only poorly reflect the level of cortical suppression and that electroencephalographic monitoring could indicate different relationships between cortical effects and haemodynamics. METHODS Anaesthesia was induced with thiopental (7 mg kg(-1)), and fentanyl (2 microg kg(-1)) with succinylcholine (1.5 mg kg(-1)) for neuromuscular blockade in the 11 patients of Group 1. In Group 2 (n = 15), thiopental (7 mg kg(-1)) and succinylcholine (1.5 mg kg(-1)) were given. In Group 3, the patients (n = 13) received thiopental (7 mg kg(-1)), fentanyl (2 microg kg(-1)) and cisatracurium (0.1 mg kg(-1)), and they were intubated 3 min later than the patients in Groups 1 and 2. We determined conventional electroencephalographic (EEG) variables and classified 14 EEG stages in real-time ranging from A (= 1), indicating full wakefulness, to F1 (= 14), at profound cortical suppression. RESULTS All groups had profound cortical suppression 45 s after thiopental administration, which rapidly decreased (EEG stage, 11 (6-13) versus 7 (2-13) at 4 min, P < 0.0001). Decreasing EEG stages were associated with increasing SEF 95, relative alpha and beta power and decreasing relative delta power. During tracheal intubation, profound cortical suppression remained unchanged in Groups 1 and 2. In Group 3, cortical suppression had decreased before laryngoscopy (P < 0.005). In Group 2, 11 patients had heart rate responses to tracheal intubation, whereas only two responded in Group 1 (P = 0.015) and three in Group 3 (P = 0.02). Thirteen patients in Group 2 had arterial pressure responses, and five in Group 1 (P = 0.038). Circulatory responses did not differ between Groups 1 and 3. CONCLUSIONS Electroencephalographic monitoring was suitable to indicate in real-time that haemodynamics only poorly reflect rapidly changing levels of cortical suppression, and how haemodynamics and cortical activity depend on the applied combination of hypnotic and analgesic drugs during anaesthesia induction with thiopental.
Collapse
Affiliation(s)
- K Raymondos
- Medical School of Hannover, Department of Anaesthesiology, Hannover, Germany.
| | | | | | | | | |
Collapse
|
18
|
Ogawa-Okamoto C, Saito S, Nishihara F, Yuki N, Goto F. Blood pressure control with glyceryl trinitrate during electroconvulsive therapy in a patient with cerebral aneurysm. Eur J Anaesthesiol 2003; 20:70-2. [PMID: 12553392 DOI: 10.1017/s0265021503210139] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
19
|
Haltiavaara KM, Laitinen JO, Kaukinen S, Viljakka TJ, Laippala PJ, Luukkaala TH. Failure of interscalene brachial plexus blockade to produce pre-emptive analgesia after shoulder surgery. Eur J Anaesthesiol 2003; 20:72-3. [PMID: 12553393 DOI: 10.1017/s0265021503220135] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
20
|
Krenn H, Deusch E, Balogh B, Jellinek H, Oczenski W, Plainer-Zöchling E, Fitzgerald RD. Increasing the injection volume by dilution improves the onset of motor blockade, but not sensory blockade of ropivacaine for brachial plexus block. Eur J Anaesthesiol 2003; 20:21-5. [PMID: 12553384 DOI: 10.1017/s0265021503000048] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE Ropivacaine used for axillary plexus block provides effective motor and sensory blockade. Varying clinical dosage recommendations exist. Increasing the dosage by increasing the concentration showed no improvement in onset. We compared the behaviour of a constant dose of ropivacaine 150 mg diluted in a 30, 40 or 60 mL injection volume for axillary (brachial) plexus block. METHODS A prospective, randomized, observer-blinded study on patients undergoing elective hand surgery was conducted in a community hospital. Three groups of patients with a constant dose of ropivacaine 150 mg, diluted in 30,40 or 60 mL NaCl 0.9%, for axillary plexus blockade were compared for onset times of motor and sensory block onset by assessing muscle strength, two-point discrimination and constant-touch sensation. RESULTS Increasing the injection volume of ropivacaine 150 mg to 60 mL led to a faster onset of motor block, but not of sensory block, in axillary plexus block, compared with 30 or 40 mL volumes of injection. CONCLUSIONS The data show that the onset of motor, but not of sensory block, is accelerated by increasing the injection volume to 60 mL using ropivacaine 150 mg for axillary plexus block. This may be useful for a more rapid determination of whether the brachial plexus block is effective. However, when performing surgery in the area of the block, sensory block onset seems more important.
Collapse
Affiliation(s)
- H Krenn
- Department of Anaesthesia and Critical Care, City Hospital, Lainz, Vienna, Austria.
| | | | | | | | | | | | | |
Collapse
|
21
|
Abstract
Non-invasive positive pressure ventilation is an emerging modality in contemporary critical care practice. Perhaps the most widely utilized and familiar form of non-invasive positive pressure ventilation is mask continuous positive airway pressure. Other common modes include mask Bi-level positive airway pressure and mask pressure support ventilation. All feature the delivery of positive airway pressure via a mask (full-face, naso-oral or nasal), and a patient-controlled respiratory cycle. The physiological benefits of non-invasive positive pressure ventilation suggested by a number of studies include improved oxygenation, decreased work of breathing, improved ventilation and perfusion matching, decreased fatigue, and increased minute ventilation. The utilization of non-invasive positive pressure ventilation has now been reported for a variety of clinical indications. In most, randomized trials are lacking, and the benefits and preferred mode of non-invasive positive pressure ventilation are still to be elucidated. In general, in patients that are candidates for endotracheal intubation, non-invasive positive pressure ventilation should be used as a way to possibly avoid endotracheal intubation rather than as an alternative to endotracheal intubation. Whilst the benefit of non-invasive positive pressure ventilation appears to be established in patients with chronic obstructive airways disease with hypercapnic acute respiratory failure, one of the major unresolved issues is whether one modality is significantly better than the others. Unfortunately, the question of whether Bi-level positive airway pressure is better than continuous positive airway pressure in this clinical scenario has not been satisfactorily addressed in any large randomized and controlled clinical trial. Further, there is no 'gold standard' for predicting success with non-invasive positive pressure ventilation, although several studies have looked at this aspect.
Collapse
Affiliation(s)
- Craig T Hore
- School of Rural Health (Mid North Coast), Faculty of Medicine, University of New South Wales, New South Wales, Australia.
| |
Collapse
|
22
|
Oczenski W, Kepka A, Krenn H, Fitzgerald RD, Schwarz S, Hörmann C. Automatic tube compensation in patients after cardiac surgery: effects on oxygen consumption and breathing pattern. Crit Care Med 2002; 30:1467-71. [PMID: 12130963 DOI: 10.1097/00003246-200207000-00011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate patients without prior pulmonary disease after cardiac surgery and to determine whether resistive unloading by automatic tube compensation, pressure support ventilation, and continuous positive airway pressure has different effects on oxygen consumption, breathing pattern, gas exchange, and hemodynamics. DESIGN Prospective, randomized, controlled study. SETTING Tertiary care, postoperative intensive care unit. PATIENTS Twenty-one patients scheduled for open heart coronary artery bypass graft surgery. INTERVENTIONS Each patient was ventilated with all three modes in random order. MEASUREMENTS AND MAIN RESULTS Patients were ventilated in three modes, each applied for 30 mins according to computer-generated randomization: pressure support ventilation with 5 cm H2O, continuous positive airway pressure, and automatic tube compensation. Oxygen consumption was calculated by means of indirect calorimetry. The hypnotic state of the patients was monitored by Bispectral Index. For hemodynamic measurements, a fiberoptic pulmonary artery catheter was inserted. The main finding of our study was that oxygen consumption and breathing pattern (tidal volume and respiratory rate) did not differ significantly during automatic tube compensation and pressure support ventilation compared with continuous positive airway pressure (oxygen consumption, 170 +/- 29 vs. 170 +/- 26 vs. 174 +/- 29 mL.min.m, respectively; tidal volume, 466 +/- 132 vs. 484 +/- 125 vs. 470 +/- 119 mL, respectively; respiratory rate, 16 +/- 4 vs. 15 +/- 4 vs. 16 +/- 4 breaths/min, respectively). Automatic tube compensation and pressure support ventilation had no clinical effects on gas exchange and hemodynamic variables compared with continuous positive airway pressure. None of the variables differed significantly during the three ventilatory settings. CONCLUSION In postoperative tracheally intubated patients with normal ventilatory demand, automatic tube compensation and pressure support ventilation with 5 cm H2O lead to identical oxygen consumption, breathing patterns, gas exchange, and hemodynamics. We, therefore, suggest that this group of patients does not need any additional positive pressure support from the ventilator to overcome the additional work of breathing imposed by the endotracheal tube during the weaning phase from mechanical ventilation.
Collapse
Affiliation(s)
- Wolfgang Oczenski
- Department of Anesthesia and Intensive Care and the Ludwig Boltzmann Institute for Economics of Medicine in Anesthesia and Intensive Care, Vienna City Hospital-Lainz, Vienna, Austria.
| | | | | | | | | | | |
Collapse
|
23
|
Abstract
On the basis of currently available data, it can be suggested that maintained spontaneous breathing during mechanical ventilation should not be suppressed even in patients with severe pulmonary dysfunction if no contraindications, such as increased intracranial pressure, are present. Improvements in pulmonary gas exchange, systemic blood flow, and oxygen supply to tissues, which have been observed when spontaneous breathing was allowed during ventilatory support, are reflected in the clinical improvement in the patient's condition, as indicated by significantly fewer days with ventilation, earlier extubation, and shorter stays in the intensive care unit. The positive effects of spontaneous breathing have been documented only for some of the available partial ventilatory support modalities. If ventilatory modalities are limited to those whose positive effects have been documented, then partial ventilatory support can be used as a primary modality even in patients with severe pulmonary dysfunction. Whereas controlled mechanical ventilation followed by weaning with partial ventilatory support modalities has been the earlier standard in ventilation therapy, this approach should be reconsidered in view of the available data.
Collapse
Affiliation(s)
- Christian Putensen
- Department of Anesthesiology and Intensive Care Medicine, University of Bonn, Germany.
| | | | | |
Collapse
|
24
|
Kuhlen R, Putensen C, Rossaint R. The Use of Ventilatory Modes allowing Spontaneous Breathing during Mechanical Ventilation. Intensive Care Med 2002. [DOI: 10.1007/978-1-4757-5551-0_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
25
|
Abstract
OBJECTIVE To evaluate which mode of preextubation ventilatory support most closely approximates the work of breathing performed by spontaneously breathing patients after extubation. DESIGN Prospective observational design. SETTING Medical, surgical, and coronary intensive care units in a university hospital. PATIENTS A total of 22 intubated subjects were recruited when weaned and ready for extubation. INTERVENTIONS Subjects were ventilated with continuous positive airway pressure at 5 cm H2O, spontaneous ventilation through an endotracheal tube (T piece), and pressure support ventilation at 5 cm H2O in randomized order for 15 mins each. At the end of each interval, we measured pulmonary mechanics including work of breathing reported as work per liter of ventilation, respiratory rate, tidal volume, negative change in esophageal pressure, pressure time product, and the airway occlusion pressure 100 msec after the onset of inspiratory flow, by using a microprocessor-based monitor. Subsequently, subjects were extubated, and measurements of pulmonary mechanics were repeated 15 and 60 mins after extubation. MEASUREMENTS AND MAIN RESULTS There were no statistical differences between work per liter of ventilation measured during continuous positive airway pressure, T piece, or pressure support ventilation (1.17+/-0.67 joule/L, 1.11+/-0.57 joule/L, and 0.97+/-0.57 joule/L, respectively). However, work per liter of ventilation during all three preextubation modes was significantly lower than work measured 15 and 60 mins after extubation (p < .05). Tidal volume during pressure support ventilation and continuous positive airway pressure (0.46+/-0.11 L and 0.44+/-0.11 L, respectively) were significantly greater than tidal volume during both T-piece breathing and spontaneous breathing 15 mins after extubation (p < .05). Negative change in esophageal pressure, the airway occlusion pressure 100 msec after the onset of inspiratory flow, and pressure time product were significantly higher after extubation than during any of the three preextubation modes (p < .05). CONCLUSIONS Work per liter of ventilation, negative change in esophageal pressure, the airway occlusion pressure 100 msec after the onset of inspiratory flow, and pressure time product all significantly increase postextubation. Tidal volume during continuous positive airway pressure or pressure support ventilation overestimates postextubation tidal volume.
Collapse
Affiliation(s)
- S Mehta
- Division of Pulmonary and Critical Care Medicine, Rhode Island Hospital/Brown University, Providence, USA
| | | | | | | | | |
Collapse
|
26
|
Mols G, Rohr E, Benzing A, Haberthür C, Geiger K, Guttmann J. Breathing pattern associated with respiratory comfort during automatic tube compensation and pressure support ventilation in normal subjects. Acta Anaesthesiol Scand 2000; 44:223-30. [PMID: 10714832 DOI: 10.1034/j.1399-6576.2000.440302.x] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND Automatic tube compensation (ATC) is a new option to support spontaneously breathing tracheally intubated patients. We have previously demonstrated an increased respiratory comfort compared to pressure support ventilation (PSV) in volunteers. Here we characterized the breathing pattern during ATC associated with respiratory comfort in comparison to PSV. Furthermore, we studied whether ATC can be substituted by a simple modification of PSV. METHODS We exposed 10 volunteers breathing through a 7.5 mm endotracheal tube via mouthpiece to PSV with 1) immediate and 2) delayed pressure rise and to 3) ATC. Immediate changes of the respiratory pattern after mode shifts were analyzed in detail. Furthermore, the volunteers were instructed to indicate changes in comfort after transitions between these modes as increased, unchanged, or decreased. RESULTS Decreased comfort was associated with a substantial increase of tidal volume, minute ventilation, gas flow, and pressure. No differences in respiratory comfort were perceived between immediate and delayed pressure rise during PSV. CONCLUSION PSV resulted in excessive tidal volumes and airflow, which was perceived as discomfort. This cannot be avoided by a delayed pressure rise but can be by the more comfortable ATC. ATC seems to adapt better to the ventilatory demand than PSV.
Collapse
Affiliation(s)
- G Mols
- Department of Anesthesiology and Critical Care Medicine, University of Freiburg, Germany.
| | | | | | | | | | | |
Collapse
|
27
|
Abstract
Weaning patients from mechanical ventilation in the intensive care unit can be difficult. In patients requiring prolonged ventilatory support it has been demonstrated that conventional weaning criteria are frequently incorrect. In this group measurement of respiratory work may be of benefit. Until recently, estimation of the work of breathing in patients receiving mechanical ventilation was logistically difficult. The availability of a computerized bedside monitoring device potentially allows easier estimation of the work of breathing at the bedside. The results of preliminary studies utilizing such monitoring are provocative: they highlight the phenomenon of nosocomial respiratory failure and challenge our clinical ability to determine patient workloads and timing of extubation. The potential benefits of work of breathing measurement, in particular the avoidance of respiratory muscle fatigue, earlier extubation, reduced duration of mechanical ventilation, reduction in ICU and hospital length of stay, and most importantly, a reduction in patient morbidity are yet to be demonstrated and concerns still exist about the monitor's accuracy.
Collapse
Affiliation(s)
- C J French
- Division of Anaesthesia, Western Hospital, Melbourne, Victoria, Australia
| |
Collapse
|
28
|
|
29
|
Ventilatory support. Acta Anaesthesiol Scand 1997. [DOI: 10.1111/j.1399-6576.1997.tb04896.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
30
|
Velarde CA, Short BL, Rivera O, Seale W, Howard R, Kolobow T. Reduced airway resistance and work of breathing during mechanical ventilation with an ultra-thin, two-stage polyurethane endotracheal tube (the Kolobow tube). Crit Care Med 1997; 25:276-9. [PMID: 9034264 DOI: 10.1097/00003246-199702000-00014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES To compare dynamic pulmonary function studies using the ultrathin walled Kolobow endotracheal tube, with conventional endotracheal tubes of similar external diameter on rabbits during mechanical ventilation. To test the hypothesis that the increased internal diameter of the Kolobow tube will result in decreased airway resistance and work of breathing. DESIGN Controlled animal study. SETTING Institutional animal research facility. SUBJECTS Adult female Dutch Belted rabbits (n = 6), weighing 1.4 to 1.6 kg. INTERVENTIONS The animals were initially intubated with a conventional endotracheal tube (2.5-mm internal diameter; 3.6-mm outer diameter); they were paralyzed and placed on a mechanical ventilator. Ventilatory settings were adjusted to obtain standard arterial blood gases: pH of 7.35 to 7.45; PaCO2 of 35 to 40 torr (4.7 to 5.3 kPa), and PaO2 of 90 to 100 torr (12.0 to 13.3 kPa). After the stabilization period, pulmonary function tests (PFTs) were measured (period 1), the conventional endotracheal tube was replaced with a Kolobow tube, and PFTs were measured again and recorded (period 2). While continuously monitoring tidal volume, the peak inspiratory pressure was decreased to match the tidal volume measured during ventilation with the conventional endotracheal tube. Once the desired tidal volume was reached, PFTs were recorded (period 3). Flows were unchanged during the experiment and the length of the endotracheal tubes was the same for both the conventional and the Kolobow tube. MEASUREMENTS AND MAIN RESULTS Mean values of the airway resistance and work of breathing from periods 1 and 3 were compared using the Student's t-test. There was a 59% decrease in total airway resistance (p = .001) and 45% decrease in the work of breathing (p = .0006). CONCLUSIONS The use of the ultrathin walled Kolobow endotracheal tube resulted in significant decreases in airway resistance and work of breathing, which has the potential for improving the ventilatory mechanics in very small premature newborns.
Collapse
Affiliation(s)
- C A Velarde
- Department of Pediatrics, George Washington University School of Medicine and Health Sciences, Children's National Medical Center, Washington, DC 20010-2970, USA
| | | | | | | | | | | |
Collapse
|
31
|
Parkes SN, Bersten AD, Holt AW, Vedig AE, Worthley LI. Noninvasive assisted ventilation in hypercapnic respiratory failure. Anaesth Intensive Care 1993; 21:111-5. [PMID: 8447580 DOI: 10.1177/0310057x9302100129] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- S N Parkes
- Intensive Care Unit, Flinders Medical Centre, South Australia
| | | | | | | | | |
Collapse
|