Simeonov N, Stefanova V. Micromorphology and analysis of dentin surfaces after preparation with Er:YAG laser and application of self-etch adhesive system with 10-MDP. A confocal laser scanning microscope study. Folia Med (Plovdiv) 2023; 65:453-459. [PMID: 38351822 DOI: 10.3897/folmed.65.e76606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 02/18/2022] [Indexed: 02/16/2024] Open
Abstract
AIM The purpose of this study was to analyze and compare the micromorphology of the hybrid layer and the dentinal surface when the dentin was prepared with an Er:YAG laser or burs, and to find if there was any difference if the time of application of the self-etching primer on the dentin prepared with an Er:YAG laser was doubled.
Collapse
|
2
|
Kamitsu T, Shimomura-Kuroki J, Shinkai K. Effect of viscosity of experimental universal adhesive on bond strength to dentin prepared with Er:YAG laser. Sci Rep 2023; 13:7900. [PMID: 37193742 DOI: 10.1038/s41598-023-34984-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 05/10/2023] [Indexed: 05/18/2023] Open
Abstract
The aim of this study was to clarify the effect of universal adhesive (UA) viscosity on the bond strength of resin composite to dentin prepared with Er:YAG laser. Four experimental UAs (SI-1, SI-2, SI-3, and SI-4) were developed by adding 1, 2, 3, and 4 wt/% nanosilica to BeautyBond Xtreme (Shofu), respectively. BeautyBond Xtreme was used as a control (SI-0). The viscosities of experimental UAs were measured using a B-type viscometer. After bovine mandibular anterior teeth were ground with #600 emery paper to obtain the flattened dentin surfaces, the dentin surfaces were cut thinly by irradiating the Er:YAG laser. Specimens were prepared using the respective UA and flowable resin composite and subjected to the microtensile bond strength (µTBS) test. The data from viscosity measurement and the μTBS test were statistically analyzed using the Kruskal-Wallis test. The mean values of viscosity significantly differed among the all experimental groups (p < 0.01). The μTBS of SI-1 and SI-2 was significantly higher than that of SI-0, SI-3, and SI-4 (p < 0.001). The μTBS of SI-0 was significantly lower than that of SI-4 (p < 0.001). The viscosities of the experimental universal adhesives significantly affected their bond strength to laser-cut dentin.
Collapse
Affiliation(s)
- Takehiro Kamitsu
- Advanced Operative Dentistry-Endodontics, The Nippon Dental University Graduate School of Life Dentistry at Niigata, 1-8 Hamaura-cho, Chuo-ku, Niigata, 951-8580, Japan
| | - Junko Shimomura-Kuroki
- Department of Pediatric Dentistry, The Nippon Dental University School of Life Dentistry at Niigata, 1-8 Hamaura-cho, Chuo-ku, Niigata, 951-8580, Japan
| | - Koichi Shinkai
- Department of Operative Dentistry, The Nippon Dental University School of Life Dentistry at Niigata, 1-8 Hamaura-cho, Chuo-ku, Niigata, 951-8580, Japan.
| |
Collapse
|
3
|
Wei D, Nakamoto A, Hiraishi N, Nakane A, Abuna G, Otsuki M, Shimada Y. Effect of Er: YAG laser irradiation with additional low energy on resin-dentin bonding and morphology of bonded interface. J Mech Behav Biomed Mater 2023; 140:105692. [PMID: 36753849 DOI: 10.1016/j.jmbbm.2023.105692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 01/22/2023] [Accepted: 01/23/2023] [Indexed: 01/26/2023]
Abstract
OBJECTIVES To examine the micro tensile bond strength (μTBS) and the resin-dentin interface on a laser-irradiated dentin surface using two different irradiation methods, with or without additional low-energy irradiation. METHODS The flat bovine dentin surface was divided into three groups: i). control group (C group, no irradiation), ii) 80 mJ/pulse Er: YAG laser group (80 group), iii) 80 + 30 mJ/pulse Er: YAG laser group (80 + 30 group, with an additional 30 mJ/pulse). After the roughness of the dentin surface was recorded, Clearfil SE Bond 2 or Clearfil Universal Bond Quick (Kuraray Noritake Dental Inc., Tokyo, Japan) was applied. After the μTBS testing, the failure mode was observed. The bonded interface was assessed using Rhodamine-dye incorporated adhesives and observed by optical coherence tomography. RESULTS The dentin surface showed opened dentinal tubules without a smear layer after irradiation. For both adhesives, the μTBS was significantly higher in 80 + 30 group than in the 80 group (p < 0.05). In the 80 group, the thickness of the adhesive layer was not uniform, and the dentin surface was occasionally in direct contact with the composite resin. The failure mode images showed that most of the fractures in the 80 group were at the sub-surface of irradiated dentin. The adhesive layers of the 80 + 30 groups were homogeneous. CONCLUSIONS The dentin surface was rough and irregular by 80 mJ irradiation, which might result in an inadequate resin-dentin interface and the weak μTBS. The bonded integrity was mitigated by additional irradiation.
Collapse
Affiliation(s)
- Diantong Wei
- Department of Cariology and Operative Dentistry, Division of Oral Health Science, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Japan
| | - Ayako Nakamoto
- Department of Cariology and Operative Dentistry, Division of Oral Health Science, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Japan
| | - Noriko Hiraishi
- Department of Cariology and Operative Dentistry, Division of Oral Health Science, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Japan.
| | - Akira Nakane
- Department of Cariology and Operative Dentistry, Division of Oral Health Science, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Japan
| | - Gabriel Abuna
- Foundational Sciences Department East Carolina University, Greenville, NC, USA
| | - Masayuki Otsuki
- Department of Cariology and Operative Dentistry, Division of Oral Health Science, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Japan
| | - Yasushi Shimada
- Department of Cariology and Operative Dentistry, Division of Oral Health Science, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Japan
| |
Collapse
|
4
|
Sayed ME. The Effect of Dentine Desensitizing Agents on the Retention of Cemented Fixed Dental Prostheses: A Systematic Review. Medicina (B Aires) 2023; 59:medicina59030515. [PMID: 36984516 PMCID: PMC10051248 DOI: 10.3390/medicina59030515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 02/28/2023] [Accepted: 03/03/2023] [Indexed: 03/09/2023] Open
Abstract
Background and Objectives: The use of desensitizing agents (DA) after tooth preparation to prevent hypersensitivity is well documented in the literature. A fixed dental prosthesis (FDP) should have good retention to be successful. Inadequate retention may result in microleakage, secondary caries, and, eventually, dislodgement of the FDP. The effect of DAs on the retention of FDPs has been widely studied in the literature, but the results are conflicting. Thus, this study aimed to conduct a systematic review to assess the effect of dentine desensitizing agents, used to prevent post-cementation hypersensitivity, on the retention of cemented FDPs. The null hypothesis framed was that there is no effect of dentine desensitizing agents on the retention of cemented FDPs. The focused PICO question was as follows: “Does the application of dentine desensitizing agents (I) affect the retention (O) of cemented fixed dental prosthesis (P) when compared to non-dentine desensitizing groups (C)”? Materials and Methods: Four electronic databases were systematically searched and, on the basis of the predefined inclusion and exclusion criteria, 23 articles were included in this systematic review. A modified CONSORT scale for in vitro studies was used to assess the quality of the selected studies, as all included studies were in vitro studies. Results: Most of the studies compared the effect of more than one type of DA on retention. The results of the selected studies varied due to differences in the composition of tested dentine DAs and types of luting cements. Conclusions: Within the limitations of this study, it can be concluded that the retention values of FDPs cemented using zinc phosphate cement were reduced with most of the DAs, whereas retention values increased when GIC, resin-modified GIC, and resin cements were used with the majority of DAs. These findings are important, as they can guide dentists in selecting the DA before cementing the crowns with the luting agent of their choice, without compromising the retention of the crowns.
Collapse
Affiliation(s)
- Mohammed E Sayed
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| |
Collapse
|
5
|
Sun G, Chen X, Wei F, Bai T, Zhu S. Effects of Er: YAG, Er,Cr: YSGG, and Nd: YAG laser irradiation and adhesive systems on the immediate and long-term bond strength of dentin: a systematic review and meta-analysis. Lasers Med Sci 2023; 38:32. [PMID: 36595096 DOI: 10.1007/s10103-022-03699-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 12/23/2022] [Indexed: 01/04/2023]
Abstract
At present, lasers are increasingly used in the oral clinical field, and research and applications in dental hard tissue treatment are also increasing. The effect of laser etching dentin on the bonding strength of composite resin reported in the literature is still inconclusive. The purpose of this review was to evaluate whether laser etching can improve the immediate and long-term bonding strength of dentin and investigate the effect of different types of adhesives on the bonding strength of dentin. Two reviewers performed a literature search up from January 2012 to November 2021 in four databases: MEDLINE (PubMed), Web of Science, EMBASE, and the Cochrane Library. A total of 25 studies were included in the meta-analysis. The Cochrane Collaboration Bias Risk Assessment tool was used to evaluate the quality of the included literature, and an analysis was carried out using Review Manager Software version 5.3. The aging bond strength of dentin after erbium (Er): yttrium aluminum garnet (YAG) laser treatment was significantly lower than that of dentin in the bur group (P < 0.00001). At the same time, the bond strength of dentin immediately and aging after (Er), chromium-doped (Cr): yttrium scandium gallium garnet (YSGG) laser treatment was lower than that of dentin in the bur group (P < 0.05). There was no significant difference in the immediate and aging bonding strength among samples in the Er: YAG laser, Er, Cr: YSGG laser, and blank control groups (no laser or bur). The aging bond strength of samples after neodymium-doped (Nd): YAG laser treatment was higher than that of samples in the blank control group (P < 0.05); in addition, the performance of self-etching adhesive was slightly better than that of acid etching adhesive. Regardless of the applied surface treatment and the adhesive employed, dentin after aging showed significant bond degradation (P < 0.05). There was high heterogeneity of bond strength between different groups, and the small number of studies and the contradictory results may be the main reasons for this outcome.
Collapse
Affiliation(s)
- Guangdi Sun
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130012, Jilin, China
| | - Xue Chen
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130012, Jilin, China
| | - Fei Wei
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130012, Jilin, China
| | - Tingting Bai
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130012, Jilin, China
| | - Song Zhu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130012, Jilin, China.
- Department of Prosthodontics, Hospital of Stomatology, Jilin University, 1500 Qinghua Road, Chaoyang District, Changchun, 130012, Jilin, China.
| |
Collapse
|
6
|
Saikaew P, Sattabanasuk V, Harnirattisai C, Chowdhury AFMA, Carvalho R, Sano H. Role of the smear layer in adhesive dentistry and the clinical applications to improve bonding performance. JAPANESE DENTAL SCIENCE REVIEW 2022; 58:59-66. [PMID: 35140823 PMCID: PMC8814382 DOI: 10.1016/j.jdsr.2021.12.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 12/08/2021] [Accepted: 12/12/2021] [Indexed: 11/23/2022] Open
Abstract
Currently, dental adhesives can be divided into two systems; a smear layer-removal approach with etch-and-rinse adhesives or a smear layer-modified approach with self-etching adhesives. After phosphoric acid etching, the smear layer is completely removed. More attention is, however, required when using self-etching adhesives. The smear layer is partially demineralized by the weak acidic monomer and subsequently incorporated into the hybrid layer. Therefore, the characteristics of the smear layer play an important role on the bonding performance of self-etching adhesives. Such characteristics, for instance, smear layer thickness and smear layer density, are influenced by many factors, e.g., instruments used for dentin surface preparation, cutting speed, and the abrasive particle size of the cutting instruments. This review discusses the contributing factors that affect the smear layer characteristics, and the influence of the smear layer on the bonding performance of dental adhesives. Also, the application techniques regarding how to improve the bonding performance of self-etching adhesives – the smear layer removal by using chemical agents, or the modification of the adhesive application procedures – are provided.
Collapse
|
7
|
Alhabdan A, Alrefeai MH, Alkhudhairy F, Alhaqbani M, Naseem M, Vohra F. Assessment of Caries-Affected Dentin Adhesive Interface Treated with Contemporary Conditioning Techniques. Photobiomodul Photomed Laser Surg 2022; 40:639-645. [PMID: 36067096 DOI: 10.1089/photob.2022.0019] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Objective: The aim of this study was to assess shear bond strength (SBS) and failure analysis of adhesion of composite resin (CR) to caries-affected dentin (CAD) pretreated with the Er,Cr:YSGG (ECY) laser, photodynamic therapy (PDT), and etch and rinse (ER) used for cavity disinfection. Materials and methods: Methods used in this study included scanning electron microscopy (SEM), SBS analysis, failure analysis, and digital microscopy. The methods were adopted to assess bond integrity, CAD interface, smear layer, and hybridization. Thirty human third molars assessed clinically and having scores of 4 and 5 based on International Caries Detection and Assessment System (ICDAS) criteria were inspected. Infected dentin was removed. Dentin that was hard and stained pink was categorized as CAD. Ten samples were used in each group for pretreatment of CAD. Ten samples of healthy dentin [sound dentin (SD)] were collected separately and taken as controls. Samples were divided into the following groups: group 1: SD+ER; group 2: CAD+ER; group 3: CAD+ECY; and group 4: CAD+PDT after the pretreatment bonding agent was applied and the restorative procedure was performed using CR. Results: CAD conditioned with PDT before bonding to CR demonstrated the lowest SBS values (11.22 ± 0.77 MPa), whereas the highest SBS values were observed in the SD surface treated with ER (18.25 ± 1.22 MPa). In CAD and SD pretreated with ER, majority of failure modes were cohesive failure and admixed failure, whereas in CAD pretreated with PDT and the ECY laser, the adhesive failure mode was pertinent. Conclusions: The use of the ECY laser and PDT on CAD for cavity disinfection does not have potential for application in clinical settings as it decreases bond integrity of CR. Moreover, the ER pretreatment method for CAD and SD remains the gold standard.
Collapse
Affiliation(s)
- Alhanouf Alhabdan
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Mohammad H Alrefeai
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Fahad Alkhudhairy
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Muneera Alhaqbani
- Department of Preventive Dentistry, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Mustafa Naseem
- Department of Community and Preventive Dentistry, Dow International Dental College, Karachi, Pakistan
| | - Fahim Vohra
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
8
|
Donmez N, Kazak M, Kaynar ZB, Sesen Uslu Y. Examination of caries-affected dentin and composite-resin interface after different caries removal methods: A scanning electron microscope study. Microsc Res Tech 2022; 85:2212-2221. [PMID: 35178808 DOI: 10.1002/jemt.24078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 01/18/2022] [Accepted: 01/24/2022] [Indexed: 11/07/2022]
Abstract
To evaluate the caries-affected dentin and composite-resin interface with scanning electron microscopy (SEM) after different caries removal methods in human molars. Twelve with extensive approximal caries lesions that did not reach the pulp and five caries-free molars (control group [CG]) were used. Carious teeth were divided into four experimental groups: Atraumatic Restorative Treatment (ART), Rotary Instrument (RI), Photo-Ablation, and Papain-Based Enzymatic Gel (Brix 3000®, Brix, Brazil). Class II slot cavities were prepared with RI in the CG. Then all caries removed teeth and control groups were restored (All-Bond Universal, BISCO, USA; Clearfil MajestyES-2, Kuraray, Japan). Specimens were prepared for SEM examinations. Hybrid layer (HL) thicknesses were measured using ImageJ programme. Gap measurements were performed with micro-CT. Data were analyzed with ANOVA and posthoc Dunnett's t-tests (p < .05). The highest HL thickness was found in Photo-Ablation Group, and a statistically significant difference was observed among the control and experimental groups (p < .05). The lowest HL thickness was measured in the Enzymatic Gel Group. In terms of internal gap formation, CG showed statistically significant differences compared to the other groups (p < .05). The highest internal gap was observed in RI Group, while the lowest gap was observed in CG. According to SEM, a uniform HL and resin tags were seen in the CG. Smear layer, irregular HL, and gap formation were observed in ART Group. In RI Group, nonuniform HL formation and resin tags were observed. In Photo-Ablation Group, a uniform HL without smear layer and internal gap was observed. In the Enzymatic Gel Group, both opened dentinal tubules, and melting-like formations were observed on the dentin surface. Especially melting-like formations were observed in peritubular dentin. It can be concluded that all caries removal methods except rotary instrumentation were conservative methods, which preserve more healthy dental tissues.
Collapse
Affiliation(s)
- Nazmiye Donmez
- Department of Restorative Dentistry, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| | - Magrur Kazak
- Department of Restorative Dentistry, School of Dental Medicine, Bahcesehir University, Istanbul, Turkey.,Department of Therapeutic Dentistry, BAU International University School of Medicine and Health Science, Batumi, Georgia
| | - Zeynep Buket Kaynar
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey
| | - Yesim Sesen Uslu
- Department of Restorative Dentistry, School of Dental Medicine, Bahcesehir University, Istanbul, Turkey
| |
Collapse
|
9
|
Aslaminabadi N, Halimi Tabrizi Z, Golsanamlou O, Estaki Z, Jamali Z. Bond strength of conventional versus modified methods for Class IV restorations in primary incisors: An in vitro study. J Dent Res Dent Clin Dent Prospects 2022; 16:123-129. [PMID: 36561382 PMCID: PMC9763657 DOI: 10.34172/joddd.2022.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 03/02/2022] [Indexed: 11/08/2022] Open
Abstract
Background. Aesthetic restorations of severely decayed anterior primary teeth are challenging due to the small size of the teeth and the large pulp chambers. Therefore, this study evaluated and compared the tensile and shear bond strengths of conventional versus modified methods (slot technique) of Cl IV restorations in primary incisors. Methods. A total of 120 extracted intact maxillary primary central and lateral incisors were divided into two groups. In group A, conventional Cl IV cavities were prepared. In group B, after conventional cavity preparation, four and three incisal slots were prepared on the incisal edges of the central and lateral incisors, respectively. All the teeth were restored using composite resin, and then the tensile and shear bond strengths were evaluated. Results. A statistically significant increase in the tensile bond strength of restorations was recorded in the modified technique compared to the conventional method (P=0.001). Although an increase in the shear bond strengths was found in the modified method, the value did not reach a statistically significant level (P=0.158). The most frequent fracture type was adhesive in the conventional group and cohesive in the modified group, considering the tensile and shear bond strength tests. In both groups, the highest average tensile bond strength was recorded in teeth with the cohesive fracture in dentin, and the lowest average was seen in the adhesive type. Conclusions. Incisal slots could increase the tensile bond strengths of Cl IV composite resin restorations in primary teeth.
Collapse
Affiliation(s)
- Naser Aslaminabadi
- Department of Pediatric Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Zohreh Halimi Tabrizi
- Department of Pediatric Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran,Corresponding author: Zohreh Halimi Tabrizi,
| | - Ozra Golsanamlou
- Department of Pediatric Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Zohreh Estaki
- Department of Pediatric Dentistry, Faculty of Dentistry, Qazvin University of Medical Sciences, Qazvin, Iran
| | - Zahra Jamali
- Department of Oral Medicine, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
10
|
Aljamhan AS, Alrefeai MH, Alhabdan A, Alhusseini SA, Farooq I, Vohra F, Naseem M, Alkhudhairy F. Influence of ER-CR-YSGG Laser and Photodynamic Therapy on the Dentin Bond Integrity of Nano-Hydroxyapatite Containing Resin Dentin Adhesive: SEM-EDX, Micro-Raman, Micro-Tensile, and FTIR Evaluation. Polymers (Basel) 2021; 13:polym13121903. [PMID: 34201060 PMCID: PMC8228082 DOI: 10.3390/polym13121903] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/12/2021] [Accepted: 05/12/2021] [Indexed: 02/06/2023] Open
Abstract
The study aimed to analyze the effect of the addition of nano-hydroxyapatite (nano-HA) particles on the mechanical properties of experimental adhesive (EA). Furthermore, dentin interaction of EA (without nano-HA) and EA with nano-HA (hereon referred to as HA-10%) were also investigated and equated. Methods consisting of scanning electron microscopy (SEM)-energy-dispersive X-ray spectroscopy (EDX), micro-Raman spectroscopy, micro-tensile bond strength (µTBS) test, and Fourier transform infrared (FTIR) spectroscopy were employed to study nano-HA particles shape, dentin bond strength, degree of conversion (DC), and adhesive-dentin interaction. Ninety teeth (N = 90) were collected, and pre-bonding, conditioning of dentin was performed utilizing phosphoric acid (H3PO4) etching, photodynamic therapy (PDT), and ER-CR-YSGG (ECY) laser. The teeth were set to form bonded specimens using two adhesives. Nano-HA particles were spherical-shaped, and EDX confirmed the presence of oxygen, calcium, and phosphorus. Micro-Raman spectroscopy revealed distinct phosphate and carbonate peaks for nano-HA. The µTBS test demonstrated highest values for HA-10% group on the H3PO4 conditioned dentin. The greatest DC was observed for the EA group. The addition of nano-HA-10 wt.% particles in dentin adhesive resulted in improved bond strength. The incorporation also demonstrated acceptable DC (although lower than EA group), suitable dentin interaction, and resin tag formation.
Collapse
Affiliation(s)
- Abdullah S. Aljamhan
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.S.A.); (M.H.A.); (A.A.); (S.A.A.)
| | - Mohammad H. Alrefeai
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.S.A.); (M.H.A.); (A.A.); (S.A.A.)
| | - Alhanouf Alhabdan
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.S.A.); (M.H.A.); (A.A.); (S.A.A.)
| | - Sarah A. Alhusseini
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.S.A.); (M.H.A.); (A.A.); (S.A.A.)
| | - Imran Farooq
- Faculty of Dentistry, University of Toronto, Toronto, ON M5G 1G6, Canada;
| | - Fahim Vohra
- Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia;
| | - Mustafa Naseem
- Department of Community and Preventive Dental Sciences, Dow International Dental College, Karachi 74200, Pakistan;
| | - Fahad Alkhudhairy
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia; (A.S.A.); (M.H.A.); (A.A.); (S.A.A.)
- Correspondence:
| |
Collapse
|
11
|
Effect of Cavity Disinfectants on Dentin Bond Strength and Clinical Success of Composite Restorations-A Systematic Review of In Vitro, In Situ and Clinical Studies. Int J Mol Sci 2020; 22:ijms22010353. [PMID: 33396354 PMCID: PMC7794949 DOI: 10.3390/ijms22010353] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 12/26/2020] [Accepted: 12/27/2020] [Indexed: 12/26/2022] Open
Abstract
Cavity disinfection becomes an important step before a dental restorative procedure. The disinfection can be obtained cleaning the dental cavity with antimicrobial agents before the use of adhesive systems. The aim of this study was to conduct a systematic review on the effect of different cavity disinfectants on restorations’ adhesion and clinical success. A search was carried out through the Cochrane Library, PubMed, and Web of Science. In vitro and in situ studies reporting results on dentin bond strength tests, and clinical studies published until August 2020, in English, Spanish and Portuguese were included. The methodological quality assessment of the clinical studies was carried out using the Revised Cochrane risk-of-bias tool. Chlorhexidine could preserve adhesion to dentin. EDTA and ethanol had positive results that should be further confirmed. Given the significant lack of scientific evidence, the use of lasers, fluoridated agents, sodium hypochlorite, or other products as cavity disinfectants should be avoided. Chlorhexidine is a safe option for cavity disinfection with adequate preservation of adhesion to dentin. Moreover, future researches should be focused on the efficacy of these disinfectants against cariogenic bacteria and their best application methods.
Collapse
|
12
|
Wang JH, Yang K, Zhang BZ, Zhou ZF, Wang ZR, Ge X, Wang LL, Chen YJ, Wang XJ. Effects of Er:YAG laser pre-treatment on dentin structure and bonding strength of primary teeth: an in vitro study. BMC Oral Health 2020; 20:316. [PMID: 33172456 PMCID: PMC7653740 DOI: 10.1186/s12903-020-01315-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 11/04/2020] [Indexed: 01/28/2023] Open
Abstract
Background To investigate the effects of Er:YAG laser pre-treatment on the dentin structure and shear bond strength of primary teeth. Methods Dentin specimens were prepared using freshly extracted intact primary molars and divided randomly into four groups based on the surface treatment applied. The control and etchant groups received no treatment and conventional acid etching treatment, respectively, while the energy and frequency groups received laser surface treatment with variable energy (50–300 mJ) and frequency (5–30 Hz) parameters. The morphology was observed using scanning electron microscopy. The surface-treated dentin slices were bonded to resin tablets, followed by thermocycle treatment. The shear strength was determined using a universal testing machine and de-bonded surfaces were observed using a stereomicroscope. Results SEM observation showed that the surface morphology of the dentin slices changed after etching as well as after Er:YAG laser pre-treatment with different energy and frequency values. The dentin tubules opened within a specific energy (50–200 mJ) and frequency (5–20 Hz) range. Beyond this range, the intertubular dentin showed cracks and structural disintegration. Shear strength tests showed no significant changes after acid etching. The shear strength increased significantly (P < 0.05) after Er:YAG laser pre-treatment compared with that of the control group. The shear strength increased within the same energy (50–200 mJ) and frequency (5–20 Hz) range as the tubule opening, but not significantly (P > 0.05). The most common mode of interface failure was adhesive (interface) failure, followed by mixed and resin cohesive failure. Conclusions Pre-treatment using Er:YAG laser opens the dentinal tubules without the formation of a smear layer and improves the bonding strength between the primary teeth dentin and the resin composites.
Collapse
Affiliation(s)
- Jun Hui Wang
- State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Disease and Shaanxi Clinical Research Center for Oral Diseases, Stomatology Department of Children, School of Stomatology, The Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shaanxi, China
| | - Kuan Yang
- Department of Orthodontics, College of Stomatology, Xi'an Jiaotong University, No. 98, Xiwu Road, Xincheng District, Xi'an, Shaanxi, China
| | - Bai Ze Zhang
- State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Disease and Shaanxi Clinical Research Center for Oral Diseases, Stomatology Department of Children, School of Stomatology, The Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shaanxi, China
| | - Zhi Fei Zhou
- Department of Stomatology, General Hospital of Tibet Military Region, Chinese People's Liberation Army, Lhasa, Tibet, China
| | - Zi Rui Wang
- State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Disease and Shaanxi Clinical Research Center for Oral Diseases, Stomatology Department of Children, School of Stomatology, The Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shaanxi, China
| | - Xin Ge
- State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Disease and Shaanxi Clinical Research Center for Oral Diseases, Stomatology Department of Children, School of Stomatology, The Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shaanxi, China
| | | | - Yu Jiang Chen
- State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Disease and Shaanxi Clinical Research Center for Oral Diseases, Stomatology Department of Children, School of Stomatology, The Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shaanxi, China
| | - Xiao Jing Wang
- State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Disease and Shaanxi Clinical Research Center for Oral Diseases, Stomatology Department of Children, School of Stomatology, The Fourth Military Medical University, No. 145, Changle West Road, Xincheng District, Xi'an, Shaanxi, China.
| |
Collapse
|
13
|
Zabeu GS, Brianezzi LFF, GonÇalves RS, Maenosono RM, Palma-Dibb RG, Wang L, Ishikiriama SK. MDP-based universal adhesive system irradiated with Er,CR:YSGG: Analysis of its performance up to 6 months. Dent Mater J 2020; 40:150-156. [PMID: 32999257 DOI: 10.4012/dmj.2019-335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study aimed to analyze the interaction of a MDP-based universal dentin bonding system (DBS) with Er, Cr: YSGG laser irradiation, measuring the microtensile bond strength to dentin over a six-month period. The experimental design involved three factors: DBS (Adper Scotchbond Universal; Clearfil SE Bond, Adper Scotchbond Multipurpose and Adper Single Bond 2), laser (Control and Er, Cr: YSGG), and time (initial- 7 days and 6 months). Eighty dentin samples from molars were prepared (n=10) with laser irradiation after primer and DBS application. After 7 days, were subjected to micro tensile bond strength test. The data were analyzed by three-way ANOVA and Tukey tests (p<0.05). Both DBS and laser significantly affected the bonding performance and their interaction was statistically significant (p=0.0194). The self-etching mode of the MDP-based universal DBS maintained the bond strength on dentin irradiated with ER, Cr: YSGG after 6 months, while bonding with all other DBS deteriorated.
Collapse
Affiliation(s)
- Giovanna Speranza Zabeu
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo
| | | | - Rafael Simões GonÇalves
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo
| | - Rafael Massunari Maenosono
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo
| | | | - Linda Wang
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo
| | - Sérgio Kiyoshi Ishikiriama
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo
| |
Collapse
|
14
|
Atalay C, Uslu A, Yazici AR. Does laser etching have an effect on application mode of a universal adhesive?-A microleakage and scanning electron microscopy evaluation. Microsc Res Tech 2020; 84:125-132. [PMID: 32852126 DOI: 10.1002/jemt.23573] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 07/05/2020] [Accepted: 07/24/2020] [Indexed: 11/11/2022]
Abstract
This study aimed to evaluate the microleakage of a universal adhesive's different application modes incorporated with Er,Cr:YSGG laser on Class V resin composite restorations. Sound human molar teeth (n = 30) were used for microleakage evaluations. Specimens with 60 standardized Class V cavities were divided into five groups according to the adhesive modes of universal adhesive, Adhese Universal (n = 12). Group 1-etch-and-rinse mode with phosphoric acid; Group 2-etch-and-rinse mode with Er,Cr:YSGG laser; Group 3-selective-etch mode with phosphoric acid; Group 4-selective-etch mode with Er,Cr:YSGG laser; Group 5-self-etch. After restorations were performed with a resin composite, Tetric N-Ceram, the specimens were polished and subjected to thermocycling (10,000X). Following immersion in 0.5% basic fuschin for a day, the teeth were sectioned and the degree of microleakage was determined along the tooth-resin composite interface using a light microscopy(40X). Five specimens from each group were examined by scanning electron microscopy. The Kruskal-Wallis, Siegel Castello, and Wilcoxon tests were used for statistical analyses (α = .05). At the enamel margins, significant differences were obtained among the groups (p < .05). Significantly higher microleakage scores were detected in Group 5 in comparison with Groups 1, 2, and 3. There were no significant differences between different adhesive strategies at the dentin margins (p > .05). While analyzing enamel and dentin microleakage scores, no statistically significant differences were observed in Groups 4 and 5 (p > .05). The laser application time and the adhesive modes of universal adhesives could affect the microleakage at the enamel margins. Different adhesive modes of universal adhesives combined with laser etching had no influence on the microleakage scores of dentin margins.
Collapse
Affiliation(s)
- Cansu Atalay
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey
| | - Aybuke Uslu
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey
| | - Ayşe Ruya Yazici
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, Turkey.,Hacettepe University Dental Laser Application and Research Center, Ankara, Turkey
| |
Collapse
|
15
|
Evaluation of bond strength of resin cement to Er:YAG laser-etched enamel and dentin after cementation of ceramic discs. Lasers Med Sci 2020; 36:447-454. [PMID: 32696424 DOI: 10.1007/s10103-020-03103-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/15/2020] [Indexed: 10/23/2022]
Abstract
The purpose of this study was to investigate the shear bond strength (SBS) of ceramic discs luted to differently etched enamel and dentin surfaces. Occlusal surfaces of 64 carious-free human molars and vestibule surfaces of 64 first maxillary incisors were ground to get flat superficial dentin and flattened enamel respectively. After generating 4 groups according to the surface etching method (37% orthophosphoric acid, Er:YAG laser-contact handpiece/scanning handpiece (1 or 2 times of scanning)), ceramic discs were luted to the surfaces with adhesive resin cement (Variolink N, Vivadent Ets., Schaan/Liechtenstein). After etching and cementation, thermocycling of 5000 cycles (Sd Mechatronık Gmbh, Feldkirchen-Westerham, Germany) and SBS test (Servopulser EHFFD1; Shimadzu, Kyoto, Japan) were performed respectively. The surface morphologies of 2 specimens, etched enamel and dentin, prepared for each group were examined with SEM analysis. Failure modes were determined under a USB digital microscope. Data were analyzed with one-way analysis of variance (ANOVA) and Tukey HSD test (α = 0.05). SBS values in dentin surfaces showed statistically significant differences (p < 0.05) among tested groups. The highest SBS among dentin groups was determined in the group which had 2 times etching by Er:YAG laser (11.42 MPa) by a scanning handpiece. No statistical differences were observed in the other dentin or enamel groups. Laser etching seems to be a viable alternative to acid etching on both enamel and dentin surfaces while double etching of dentin with a scanning handpiece can improve the adhesion.
Collapse
|
16
|
Bülbül B, Beyaz S, Akar M. Preparation of water-soluble amorphous erbium borate (ErBO3.3H2O) nanoparticles with positive charge. CHEMICAL PAPERS 2020. [DOI: 10.1007/s11696-019-00940-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
17
|
Takeguchi A, Inoue K, Horie T, Niwa Y, Sugita Y, Yamada M, Maeda H, Tomoda S, Fujitani M. Development of a Novel Optimal Resin-bonding System for Er:YAG Laser-irradiated Dentin: Effects of 3-step Resin-modified Glass-ionomer Bonding System Incorporating Acid-conditioning and Priming on Initial Bond Strength to Er:YAG Laser-irradiated Dentin and its Durability after Thermal Loading. J HARD TISSUE BIOL 2020. [DOI: 10.2485/jhtb.29.239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Ayumi Takeguchi
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| | - Kazuho Inoue
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| | - Taku Horie
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| | - Yukari Niwa
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| | - Yoshihiko Sugita
- Department of Oral Pathology, School of Dentistry, Aichi Gakuin University
| | - Mitsuyoshi Yamada
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| | - Hatsuhiko Maeda
- Department of Oral Pathology, School of Dentistry, Aichi Gakuin University
| | - Shigetaka Tomoda
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| | - Morioki Fujitani
- Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University
| |
Collapse
|
18
|
Kahvecioglu F, Kahraman K, Akman H, Tosun G. Effects of Er:YAG Laser Treatment on the Mineral Content and Morphology of Primary Tooth Enamel. Photomed Laser Surg 2019; 36:680-686. [PMID: 31697638 DOI: 10.1089/pho.2018.4482] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Objective: The aim of this study was to evaluate the mineral content and morphology of primary tooth enamel prepared using an Er:YAG laser at different power settings. Materials and methods: The buccal surfaces of 45 noncarious primary molars were assessed in this study. The surfaces were cleaned and the teeth were randomly divided into nine groups (n = 5 each) to evaluate the effects of Er:YAG laser treatment at different energy levels: 200 mJ, 2 Hz; 200 mJ, 3 Hz; 200 mJ, 10 Hz; 250 mJ, 2 Hz; 250 mJ, 3 Hz; 250 mJ, 10 Hz; 300 mJ, 2 Hz; 300 mJ, 3 Hz; and 300 mJ, 10 Hz. The mean percentage weight (wt%) of calcium (Ca), phosphorous (P), fluoride (F), magnesium (Mg), potassium (K), and sodium (Na) in the primary tooth enamel was calculated for each group using scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy before and after laser application. The enamel morphology was also evaluated using SEM. The obtained data were statistically analyzed by one-way analysis of variance and Tukey's honest significant difference test. Results: The mean wt% of Ca, P, and F in the enamel exhibited a significant change after laser treatment (p < 0.05); the wt% of Mg, K, and Na remained unchanged (p > 0.05). There was no association between the power setting of the laser and changes in the wt% of minerals in the enamel (p > 0.05). SEM showed that enamel irradiated at different energy levels exhibited a characteristic lava flow appearance, and more surface irregularities were observed with the 250-mJ setting than with the 200-mJ setting. Conclusions: Our findings suggest that the mineral content and morphology of the enamel of primary teeth are affected by Er:YAG laser irradiation.
Collapse
Affiliation(s)
- Firdevs Kahvecioglu
- Department of Pediatric Dentistry, Faculty of Dentistry, Selcuk University, Konya, Turkey
| | | | - Hayri Akman
- Department of Pediatric Dentistry, Faculty of Dentistry, Alaaddin Keykubat University, Alanya, Turkey
| | - Gül Tosun
- Department of Pediatric Dentistry, Faculty of Dentistry, Selcuk University, Konya, Turkey
| |
Collapse
|
19
|
Valério RA, Galo R, Galafassi D, Corona SAM, Borsatto MC. Four-year clinical prospective follow-up of resin composite restoration after selective caries removal using Er:YAG laser. Clin Oral Investig 2019; 24:2271-2283. [PMID: 31686235 DOI: 10.1007/s00784-019-03082-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 09/22/2019] [Indexed: 12/18/2022]
Abstract
OBJECTIVES The aim of this study was to longitudinally evaluate, after a 4-year period, the clinical longevity of composite resin restoration compared to the baseline, after selective caries removal in permanent molars using Er:YAG laser or bur preparation with biomodification of dentin with the use of chlorhexidine. METHODS Selective caries removal was performed on 80 teeth of 20 individuals who each had at least four active carious lesions. These lesions, located on occlusal surfaces of permanent molar counterparts, were removed using (i) Er:YAG laser biomodified with chlorhexidine, (ii) Er:YAG laser and application of deionized water, (iii) bur preparation biomodified with chlorhexidine, and (iv) bur preparation and application of deionized water. At the end of 4 years, 64 of the 80 restorations were evaluated in 16 individuals (n = 16). The restorations were evaluated, both clinically and photographically, using scanning electron microscopy (SEM) and pulp vitality analysis. The experimental data were statistically evaluated by kappa, Fisher's, and chi-square tests, with a significance level of 5%. The Kaplan-Meier test and the Cox regression analysis were used to evaluate the survival of the restorations. RESULTS After 4 years of follow-up, there was a statistically significant difference in marginal discoloration criteria for all of the groups evaluated. For marginal adaptation criteria, there was a statistically significant difference for the Er:YAG laser group biomodified with chlorhexine (p = 0.050). For clinical and radiographic evaluation of pulp vitality, there were no statistically significant differences among the groups (p = 0.806). CONCLUSION Er:YAG laser can be used for selective caries removal, regardless of dentin biomodification with chlorhexidine or application of deionized water, once it produced promising results in composite resin restorations after 4 years of follow-up, according to the criteria evaluated. The selective caries removal using Er:YAG laser or bur and the biomodification of dentin with the use of chlorhexidine did not influence the survival of composite resin restorations after the 4-year follow-up period. CLINICAL RELEVANCE Composite resin restorations applied after selective caries removal using Er:YAG laser or burs, regardless of dentin biomodification with the use of chlorhexidine or application of deionized water, showed adequate clinical behavior after 4 years of follow-up.
Collapse
Affiliation(s)
- Rodrigo Alexandre Valério
- Clinical Pediatric Dentistry Department, Ribeirão Preto School of Dentistry / São Paulo University, Café Avenue, Monte Alegre, Ribeirão Preto, SP, 14040-904, Brazil
| | - Rodrigo Galo
- Department of Dentistry, Universidade Federal do Vale do Jequitinhonha e Mucuri (UFVJM), Rodovia MGT 367 - Km 583, n° 5000 Alto da Jacuba, Diamantina, Minas Gerais, 39100-000, Brazil
| | - Daniel Galafassi
- Department of Restorative Dentistry, School of Dentistry, Meridional College-IMED, Senador Pinheiro, 304, Cruzeiro, Passo Fundo, Rio Grande do Sul, 99070-220, Brazil
| | - Silmara Aparecida Milori Corona
- Restorative Dentistry Department, Ribeirão Preto School of Dentistry / São Paulo University, Café Avenue, Monte Alegre, Ribeirão Preto, SP, 14040-904, Brazil
| | - Maria Cristina Borsatto
- Clinical Pediatric Dentistry Department, Ribeirão Preto School of Dentistry / São Paulo University, Café Avenue, Monte Alegre, Ribeirão Preto, SP, 14040-904, Brazil.
| |
Collapse
|
20
|
Rattanacharoenthum A, Na-Lamphun P, Kantrong N. Altered adhesion of dental sealant to tooth enamel microscopically modified by Er:YAG laser irradiation: An in vitro study. Laser Ther 2019; 28:19-25. [PMID: 31190694 DOI: 10.5978/islsm.28_19-or-02] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 10/28/2018] [Indexed: 11/06/2022]
Abstract
Background and Aims Er:YAG laser has become optional for enamel and dentin preparation for a decade. However, it is unclear if Er:YAG laser is acceptable for enamel conditioning prior to an application of a pit-and-fissure sealant. This in vitro study thus aimed to investigate shear bond strength of a sealant to enamel etched with Er:YAG laser, as well as to demonstrate an alteration of enamel surface after the laser was applied. Materials and Methods One hundred and twenty extracted human premolars were divided into 4 groups (N = 30 per group) in which the enamel surfaces were treated with 1) 37% phosphoric acid, 2) Er:YAG laser 80 mJ/pulse, 2 Hz, 3) Er:YAG laser 120 mJ/pulse, 10 Hz, and 4) Er:YAG laser 140 mJ/pulse, 2 Hz. Prior to sealant application. Shear bond strength was determined by using a universal testing machine. Statistical analysis was performed using One-way ANOVA. Modification of enamel surface after laser ablation was also investigated using scanning electron microscope. Results Phosphoric acid-etched enamel yielded the highest shear bond strength when bonded with a sealant. Ablation of enamel with Er:YAG laser did not significantly improve sealant bonding since it demonstrated lower shear bond strength, compared to acid-etched enamel. Despite the presence of cracks after Er:YAG laser application, dissolution of enamel substances was limited. Conclusion Our study has shown a reduced shear bond strength of dental sealant to an Er:YAG laser-irradiated enamel, compared with phosphoric acid-etched enamel.
Collapse
Affiliation(s)
- Anoma Rattanacharoenthum
- Department of Pediatric Dentistry, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | | | - Nutthapong Kantrong
- Department of Restorative Dentistry, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
21
|
Silva AC, Melo P, Ferreira J, Oliveira S, Gutknecht N. Influence of grape seed extract in adhesion on dentin surfaces conditioned with Er,Cr:YSGG laser. Lasers Med Sci 2019; 34:1493-1501. [PMID: 30830558 DOI: 10.1007/s10103-019-02749-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Accepted: 02/12/2019] [Indexed: 11/26/2022]
Abstract
The proanthocyanidin (PA)-rich grape seed extract (GSE) is a collagen cross-linking agent that can perform a chemical bond with the dentin's collagen. The objective of this study was to evaluate the influence on shear bond strength (SBS) of the pre-conditioning of GSE, on human dentin surfaces conditioned with Er,Cr:YSGG laser. The sample consisted of 64 non-carious human teeth, divided into eight groups, four groups conditioned with Er,Cr:YSGG laser (4.5 W, 50 Hz, 50 μs, 70% air, 90% water) and four prepared with conventional methods (control). In both groups, a GSE solution was applied before using the two adhesives tested: Clearfil™ SE Bond (CSE) and Scotchbond™ Universal (SU). Subsequently, a SBS test, a scanning electron microscopy, and a statistical analysis were performed. In the laser groups, the best SBS mean (20.08 ± 4.01 MPa) was achieved in the group treated with GSE and CSE. The control group with the application of CSE showed the highest SBS mean (24.27 ± 10.28 MPa), and the group treated with laser and SU showed the lowest SBS mean (12.94 ± 6.51 MPa). Between these two groups there was a statistically significant difference (p = 0.05). However, this was not observed among the laser or control groups. The type of dentin surface preparation can influence the SBS. The CSE showed better SBS in laser and control groups. The presence of GSE did not improve the adhesion on surfaces conditioned with laser, but more studies should be carried out in the future to confirm this conclusion.
Collapse
Affiliation(s)
- Ana C Silva
- Department of Operative Dentistry, Faculdade de Medicina Dentária da Universidade do Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal.
| | - Paulo Melo
- Department of Operative Dentistry, Faculdade de Medicina Dentária da Universidade do Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal
| | - João Ferreira
- Department of Operative Dentistry, Faculdade de Medicina Dentária da Universidade do Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal
| | - Sofia Oliveira
- Department of Dental Biomaterials, Faculdade de Medicina Dentária da Universidade de Lisboa, Rua Professora Teresa Ambrósio, Cidade Universitária, 1600-277, Lisbon, Portugal
| | - Norbert Gutknecht
- Department of Operative Dentistry, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| |
Collapse
|
22
|
Trevelin LT, da Silva BTF, de Freitas PM, Matos AB. Influence of Er:YAG laser pulse duration on the long-term stability of organic matrix and resin-dentin interface. Lasers Med Sci 2019; 34:1391-1399. [PMID: 30762196 DOI: 10.1007/s10103-019-02739-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 01/25/2019] [Indexed: 02/07/2023]
Abstract
The purpose of this study was to explore the influence of Er:YAG laser irradiation with different pulse durations on the organic matrix, micromorphology of the hybrid layer (HL), and bond strength over time. Sixty caries-free human molars were cut to obtain flat dentin surfaces which were randomly divided into 4 groups: control (not irradiated-G1) and laser groups (80 mJ/2 Hz) with pulse duration ranging between 50 (G2), 300 (G3), and 600 μs (G4). A self-etch adhesive system (Universal 3M ESPE) was applied on pre-treated dentin surfaces and cylinders of resin composite were built up and stressed in a universal testing machine (μSBS) at 24 h and after12 months (n = 12). In addition, 3 other dentin-bonded specimens were prepared as previously described for each group with the adhesive doped with 0.1 wt% Rhodamine B to analyze hybrid layer morphology under Confocal Laser Microscope Scanning (CLMS). Organic matrix and collagen fibrils were analyzed by second harmonic generation (SGH). Two-way ANOVA and Tukey's test detected significantly higher μSBS values for the control group, whereas the lower values were observed in all laser groups at 24 h (p < 0.05). Storage in artificial saliva did not reduce μSBS in all groups. The low signal emitted by SHG images below the irradiated area demonstrated thermal damage of the collagen matrix. CLMS images of laser groups exhibited thicker and irregular resin-dentin interfaces than the control group. Regardless of the pulse duration, Er:YAG laser pre-treatment altered the organic matrix and HL formation which resulted in low μSBS values at 24 h. The alterations on dentin's organic structure did not jeopardize the μSBS after 1 year of saliva storage.
Collapse
Affiliation(s)
- Livia Tosi Trevelin
- Department of Operative Dentistry, School of Dentistry, University of Sao Paulo, Av. Prof. Lineu Prestes, 2227, Cidade Universitária, São Paulo, SP, 05508-000, Brazil. .,Department of Operative Dentistry, School of Dentistry, University of Cruzeiro do Sul, Av. Rua Galvão Bueno, 868, São Paulo, SP, 01506-000, Brazil.
| | - Beatriz Togoro Ferreira da Silva
- Department of Operative Dentistry, School of Dentistry, University of Sao Paulo, Av. Prof. Lineu Prestes, 2227, Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| | - Patrícia Moreira de Freitas
- Department of Operative Dentistry, School of Dentistry, University of Sao Paulo, Av. Prof. Lineu Prestes, 2227, Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| | - Adriana Bona Matos
- Department of Operative Dentistry, School of Dentistry, University of Sao Paulo, Av. Prof. Lineu Prestes, 2227, Cidade Universitária, São Paulo, SP, 05508-000, Brazil
| |
Collapse
|
23
|
Curylofo-Zotti FA, Scheffel DLS, Macedo AP, Souza-Gabriel AED, Hebling J, Corona SAM. Effect of Er:YAG laser irradiation and chitosan biomodification on the stability of resin/demineralized bovine dentin bond. J Mech Behav Biomed Mater 2019; 91:220-228. [PMID: 30597375 DOI: 10.1016/j.jmbbm.2018.12.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 12/07/2018] [Accepted: 12/18/2018] [Indexed: 12/14/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effect of Er:YAG laser for selective removal of carious lesion, followed by biomodification with chitosan on the microtensile bond strength (µTBS), adhesive interface, dry mass loss and hydroxyproline release (HYP). METHODS Artificial lesions were created in 104 bovine dentin blocks. Blocks were divided according to caries removal method: bur or Er:YAG laser. Seventy-six blocks were acid etched and subdivided according to dentin biomodification: no chitosan and 2.5% chitosan. Composite resin restorations were performed. Blocks were sectioned into beams and stored in water. After 24 h, 6 and 12 months, beams were submitted to μTBS test (n = 10) and analysis of adhesive interface by SEM (n = 3). The other 28 blocks were sectioned into beams and initial dry mass (DM) was determined (n = 7). Beams were stored and after 7 days, DM was redetermined. HYP release (n = 7) was evaluated by ELISA. Data were analyzed by ANOVA and Bonferroni's tests (α = 0.05). RESULTS After 24 h, the highest µTBS was found for bur (p < 0.001). After 6 months, methods were similar (p = 0.432). After 12 months, laser-irradiated dentin showed the highest µTBS values (p = 0.025). Chitosan promoted higher µTBS values after 6 (p = 0.011) and 12 months (p < 0.001) preserving adhesive interface. Dry mass loss and HYP release were not influenced (p > 0.05) by caries removal method or by dentin biomodification. CONCLUSION The bond strength to demineralized dentin reduced over 50% in all groups after water storage. From 6 months of water storage, Er:YAG laser irradiation and biomodification with chitosan maintained the stability of the resin-dentin bonds, but did not influence dry mass loss and HYP release.
Collapse
Affiliation(s)
- Fabiana Almeida Curylofo-Zotti
- Department of Restorative Dentistry, Ribeirao Preto School of Dentistry/São Paulo University, Ribeirão Preto, São Paulo, Brazil.
| | - Débora Lopes Salles Scheffel
- Department of Orthodontics and Pediatric Dentistry, Araraquara School of Dentistry, UNESP - Univ Estadual Paulista, Araraquara, São Paulo, Brazil
| | - Ana Paula Macedo
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry/São Paulo University, Ribeirão Preto, São Paulo, Brazil
| | | | - Josimeri Hebling
- Department of Orthodontics and Pediatric Dentistry, Araraquara School of Dentistry, UNESP - Univ Estadual Paulista, Araraquara, São Paulo, Brazil
| | - Silmara Aparecida Milori Corona
- Department of Restorative Dentistry, Ribeirao Preto School of Dentistry/São Paulo University, Ribeirão Preto, São Paulo, Brazil
| |
Collapse
|
24
|
Almojaly SA, Sulaiman Al-Hamdan R, Alrahlah A, Qutub OA, Alnajashi S, Vohra F, Abduljabbar T. Effect of Er,Cr:YSGG on bond strength and microleakage of dentin bonded to resin composite with different distance and irradiation time. Photodiagnosis Photodyn Ther 2018; 25:204-207. [PMID: 30713140 DOI: 10.1016/j.pdpdt.2018.10.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 10/21/2018] [Accepted: 10/25/2018] [Indexed: 11/19/2022]
Abstract
BACKGROUND To explore the surface modification of dentin using Er,Cr:YSGG phototherapy and bonding system on the shear bond strength and microleakage scores at two different distances and times of laser irradiation. MATERIALS AND METHODS Ninety disease-free third molars were collected for the experiment. The four laser groups were divided on the basis of non-contact mode distance and time of irradiation: Group-I: Distance of 1 mm with duration of 60 s; Group-II: Distance of 1 mm with duration of 120 s; Group-III: Distance of 2 mm with duration of 60 s and; Group-IV: Distance of 2 mm with duration of 120 s. The surface for control group (Group-EB: Etch & bond group) was treated with etch and rinse bonding regime. Specimens from all the groups were assessed for shear bond strength and microleakage scores. Samples from all groups were immersed in 2% methylene blue for 24 h and assessed under a digital microscope for microleakage. RESULTS The lowest bond strength and microleakage was observed in the control group EB. The maximum bond strength score was observed in Group-IV with mean scores 23.41 ± 1.83, while the maximum microleakage scores were observed in Group-II and Group-IV with mean scores 1.0 ± 0.36 and 1.0 ± 0.11, respectively. The lowest bond strength and microleakage among laser groups was observed in Group-II and Group-III, respectively. However, specimens in laser groups showed comparable bond strength and microleakge scores (p > 0.05). For bond strength and microleakage values, analysis of variance showed significant difference among the study groups (p < 0.001). Using Tukey post hoc test, bond strength and microleakage of laser groups showed statistically significant values than EB group. CONCLUSION Use of phototherapy using Er,Cr:YSGG for dentin surface treatment has the potential for clinical application in comparison to conventional conditioning technique. Increasing the distance of laser application and time of irradiation has significant effect on the shear bond strength and microleakage scores of dentin bonded to resin composite. However, further in-vitro analysis should be undertaken in order to prove such findings.
Collapse
Affiliation(s)
| | - Rana Sulaiman Al-Hamdan
- Department of Restorative Dental Science, Operative Division, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Ali Alrahlah
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University. Eng. Abdullah Bugshan research chair for Dental and Oral Rehabilitation, Riyadh, Saudi Arabia
| | - Osama A Qutub
- Oral and Maxillofacial Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Saudi Arabia
| | | | - Fahim Vohra
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University. Eng. Abdullah Bugshan research chair for Dental and Oral Rehabilitation, Riyadh, Saudi Arabia
| | - Tariq Abduljabbar
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University. Eng. Abdullah Bugshan research chair for Dental and Oral Rehabilitation, Riyadh, Saudi Arabia.
| |
Collapse
|
25
|
Gan J, Liu S, Zhou L, Wang Y, Guo J, Huang C. Effect of Nd:YAG Laser Irradiation Pretreatment on the Long-Term Bond Strength of Etch-and-Rinse Adhesive to Dentin. Oper Dent 2018; 42:62-72. [PMID: 27689772 DOI: 10.2341/15-268-l] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To investigate the effect of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser irradiation pretreatment on the long-term bond strength of an etch-and-rinse adhesive to dentin. METHODS Fifty molars were sectioned parallel to the occlusal plane and randomly divided into two groups (n=25 per group): control group (no treatment) and laser group (dentin surfaces were treated with Nd:YAG laser at a setting of 100 mJ/10 Hz). Afterward, resin was bonded to the dentin surface using a two-step etch-and-rinse adhesive (Adper SingleBond 2), and then 150 beams of each group were produced. Each group was divided into three subgroups (n=50 each group): 24 hours of water storage, thermocycling, and NaOCl storage. The microtensile bond strength (MTBS), failure modes, nanoleakage expression, and Masson's trichrome staining were evaluated. An additional 20 molars were sectioned to obtain 2-mm-thick flat dentin slices. These slices were randomly divided into control and laser-treated groups as mentioned previously. Then slices of each group were examined by scanning electron microscopy, attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), X-ray diffraction (XRD), and the Knoop hardness test. RESULTS The results of ATR-FTIR and Masson's trichrome verified that laser irradiation partly removed collagen fibers from the dentin surface; however, no significant difference was found in the Knoop hardness (p>0.05). The XRD result showed similar crystalline structure regardless of laser pretreatment. There is no significant difference in short-term MTBS between control and laser-treated groups (p>0.05); however, long-term MTBS differed between the groups (p>0.05). Furthermore, the laser-treated group showed less silver deposition than the control group after aging (p<0.05). CONCLUSION Pretreatment by Nd:YAG laser irradiation appeared to have a positive effect on the adhesive-dentin bonding in vitro test, and the bonding effectiveness could be preserved after aging.
Collapse
|
26
|
Influence of laser structuring of PEEK, PEEK-GF30 and PEEK-CF30 surfaces on the shear bond strength to a resin cement. J Mech Behav Biomed Mater 2018; 84:225-234. [DOI: 10.1016/j.jmbbm.2018.05.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 05/07/2018] [Indexed: 11/19/2022]
|
27
|
Kallis A, Tolidis K, Gerasimou P, Dionysopoulos D. Qualitative evaluation of hybrid layer formation using Er:YAG laser in QSP mode for tooth cavity preparations. Lasers Med Sci 2018; 34:23-34. [PMID: 29982880 DOI: 10.1007/s10103-018-2575-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 06/27/2018] [Indexed: 11/28/2022]
Abstract
The purpose of this study was to evaluate the thickness and qualitative characteristics of the hybrid layer after two cavity preparation methods, using Er:YAG laser in QSP mode and conventional carbide burs. Additionally, two different adhesive techniques were investigated using etch-and-rinse and self-etch adhesive systems. Sixty sound human third molars were used and were randomly divided into four groups (n = 15). In the first two groups, large (4 mm length, 3 mm wide, and 3 mm deep) class I cavities were prepared using Er:YAG laser (2.94 μm) in QSP mode, while in the other two groups, the cavities were prepared using carbide burs. After cavity preparations, two different adhesive techniques with GLUMA® 2 Bond (etch-and-rinse) and Clearfil™ Universal Bond Quick (self-etch) were applied. For the qualitative evaluation of the formed hybrid layer, photomicrographs were taken using SEM, and elemental semi-quantitative analysis was performed using EDS to confirm the extent of the hybrid layer. One-way ANOVA was applied to verify the existence of statistically significant differences, followed by Tukey test for post hoc comparisons (Bonferroni corrected), and the level of significance was set at a = 0.05. The laser-treated groups exhibited higher hybrid layer thickness than bur-treated groups (p < 0.001). Between the laser-treated groups, etch-and-rinse technique presented higher hybrid layer thickness than self-etch technique (p < 0.001), while between the bur-treated groups, no significant differences were detected (p = 0.366). Er:YAG laser cavity preparations in QSP mode may be advantageous for adhesion of composite restorations, but more data are necessary to confirm its clinical effectiveness.
Collapse
Affiliation(s)
- Antonis Kallis
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
| | - Kosmas Tolidis
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| | - Paris Gerasimou
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| | - Dimitrios Dionysopoulos
- Department of Operative Dentistry, School of Dentistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| |
Collapse
|
28
|
Nahas P, Zeinoun T, Namour M, Ayach T, Nammour S. Effect of Er:YAG laser energy densities on thermally affected dentin layer: Morphological study. Laser Ther 2018; 27:91-97. [PMID: 30087527 PMCID: PMC6062675 DOI: 10.5978/islsm.18-or-07] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 02/21/2018] [Indexed: 01/23/2023]
Abstract
BACKGROUND AND AIMS Physical and chemical composition of dentin is subject to modification when irradiated with Er:YAG laser. Temperature rise causes water evaporation and micro-mechanical ablation of dentin. The misuse of laser parameters could affect negatively dentin collagen fibers leading to failure in bonded composite restorations. The aim of this in vitro study was to evaluate the effect of Er:YAG laser radiation at different levels of energy on the morphology of thermally affected dentin layer. MATERIALS AND METHODS Forty-eight freshly extracted human third molars were randomly divided into six groups (n = 8). In all groups, except for the control groups, dentin was subject to irradiation with H02 handpiece Er:YAG laser in non-contact mode (SSP mode = 50 µs; 10 Hz; speed of 1 mm/second; air 6 mL/min; and water 4 mL/min) with the following levels of energy (40, 60, 80, 100, and 120 mJ) respectively. Teeth were sliced longitudinally. Photo-ablated cavities were observed. The cavity depth and dentin fiber collagen deterioration were measured. RESULTS Laser irradiation increased the depth of dentinal crater from 46.57 µm to 178.2 µm, when energy level increased from 40 mJ to 120 mJ. A superficial black layer, representing dentinal affected collagen fibers, was present in all groups except for control group. When comparing the thickness of the black layer, there was no significant difference between groups. It increased at 40 mJ to 28.17 µm then decreased to 15.19 µm at 60 mJ and then increased again for 80 mJ to 19.93 µm, 100 mJ to 22.87 µm and 120 mJ to 28.53 µm. Only one group (60 mJ) showed low values and significant difference as compared to the other irradiated groups, when multiple comparisons tests (ANOVA) were made using Newman-Keuls test. CONCLUSION Dentin organic matrix presented the minimum alteration when Er:YAG laser is used specifically at an appropriate level of energy (60 mJ).
Collapse
Affiliation(s)
- P. Nahas
- Lebanese University, Department of Restorative and Esthetic Dentistry, Beirut, Lebanon
| | - T. Zeinoun
- Lebanese University, Department of Oral and Maxillo-Facial Surgery, Beirut, Lebanon
| | - M. Namour
- University of Liege, Department of Dental Sciences, Belgium
| | - T. Ayach
- University of Liege, Department of Dental Sciences, Belgium
| | - S. Nammour
- University of Liege, Department of Dental Sciences, Belgium
| |
Collapse
|
29
|
de Los Angeles Moyaho-Bernal M, Contreras-Bulnes R, Rodríguez-Vilchis LE, Rubio-Rosas E. Changes in deciduous and permanent dentinal tubules diameter after several conditioning protocols: In vitro study. Microsc Res Tech 2018; 81:865-871. [PMID: 29737583 DOI: 10.1002/jemt.23048] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 04/10/2018] [Accepted: 04/16/2018] [Indexed: 11/10/2022]
Abstract
Innovators conditioning protocols are emerged in permanent dentin, however for deciduous dentin the information is limited; the aim of this study was to evaluate in vitro diameter of deciduous and permanent dentinal tubules after several conditioning protocols. Eighty dentin samples were distributed in sixteen groups (n = 5 p/g) and dentin surface was conditioned as follow: G1D/G1P acid etching; G2D/G2P, self-etch adhesive; G3D/G3P, G4D/G4P, Er: YAG laser irradiation at 200 mJ-25.5 J/cm2 and 300 mJ-38.2 J/cm2 , at 10 Hz under water spray respectively; G5D/G5P, G6D/G6P, G7D/G7P, and G8D/G8P were irradiated under the same energy densities followed phosphoric acid or self-etch adhesive conditioning. The sample dentin of deciduous and permanent teeth was analyzed with scanning electron microscopy and tubule diameter was evaluated by Image Tools Scandium program. Data were subjected to one-way analysis ANOVA to compare among groups with a level of significance at p ≤ .05. For deciduous dentin, diameters were from 1.52 ± 0.32 µm in G3D to 3.88 ± 0.37 µm in G1D; narrowest and widest diameter, respectively (p < .000). While permanent dentin tubules exhibited diameters from 1.16 ± 0.16/1.19 ± 0.12 µm in G7P/G8P to 2.76 ± 0.28 µm in G6P; narrowest and widest diameter, respectively (p < .000). All dentin conditioning protocols produced more open dentin tubules (diameter size) in deciduous dentin than permanent, specific conditioning protocols are required for each tissue (deciduous or permanent dentin), since same protocol produced stronger effects on primary dentin, which is important for dental clinical success in children and adolescents.
Collapse
Affiliation(s)
- María de Los Angeles Moyaho-Bernal
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO), Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca, Estado de México, C.P. 50130, México
| | - Rosalía Contreras-Bulnes
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO), Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca, Estado de México, C.P. 50130, México
| | - Laura Emma Rodríguez-Vilchis
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO), Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca, Estado de México, C.P. 50130, México
| | - Efraín Rubio-Rosas
- Benemérita Universidad Autónoma de Puebla, Centro Universitario de Vinculación y Transferencia de Tecnología, B, Prolongación de la 24 Sur y Av. San Claudio, Ciudad Universitaria, Col. San Manuel, Puebla, C.P. 72570, México
| |
Collapse
|
30
|
de los Angeles Moyaho-Bernal M, Contreras-Bulnes R, Rodríguez-Vilchis LE, Rubio-Rosas E, Scougall-Vilchis RJ, Centeno-Pedraza C. Morphological and chemical changes in human deciduous dentin after phosphoric acid, self-etching adhesive and Er: YAG laser conditioning. Microsc Res Tech 2018; 81:494-501. [DOI: 10.1002/jemt.23003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 12/27/2017] [Accepted: 01/26/2018] [Indexed: 11/10/2022]
Affiliation(s)
- María de los Angeles Moyaho-Bernal
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO); Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca; Estado de México C.P, 50130 México
| | - Rosalía Contreras-Bulnes
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO); Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca; Estado de México C.P, 50130 México
| | - Laura Emma Rodríguez-Vilchis
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO); Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca; Estado de México C.P, 50130 México
| | - Efraín Rubio-Rosas
- Benemérita Universidad Autónoma de Puebla, Centro Universitario de Vinculación; Prolongación de la 24 Sur y Av. San Claudio, Ciudad Universitaria, Col. San Manuel, Puebla C.P, 72570 México
| | - Rogelio José Scougall-Vilchis
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO); Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca; Estado de México C.P, 50130 México
| | - Claudia Centeno-Pedraza
- Universidad Autónoma del Estado de México, Facultad de Odontología, Centro de Investigación y Estudios Avanzados en Odontología (CIEAO); Jesús Carranza Esq. Paseo Tollocan, Col. Universidad, Toluca; Estado de México C.P, 50130 México
| |
Collapse
|
31
|
He Z, Chen L, Hu X, Shimada Y, Otsuki M, Tagami J, Ruan S. Mechanical properties and molecular structure analysis of subsurface dentin after Er:YAG laser irradiation. J Mech Behav Biomed Mater 2017. [PMID: 28646753 DOI: 10.1016/j.jmbbm.2017.05.036] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
The purpose of this study was to evaluate the chemical and mechanical modifications in subsurface dentin layer after Er: YAG (Erbium-Yttrium Aluminium Garnet) laser irradiation, as the guidance of new dental restorative materials specific for laser irradiated dentin. MATERIALS AND METHODS Dentin disks obtained from extracted human molars were prepared and exposed to a single pulse Er:YAG laser irradiation at 80mJ/pulse. After laser irradiation the mechanical and chemical characteristics of intertubular dentin in subsurface layer were studied using nanoindentation tester and micro-Raman spectromy (μ-RS). The dentin 5-50µm depth beneath the lased surface was determined as testing area. Two-way analysis of variance (ANOVA) were used to compare the mechanical values between lased and untreated subsurface dentin (P = 0.05). RESULTS A laser affected subsurface dentin layer after Er:YAG laser treatment is present. The laser irradiation is considered to decrease the mechanical properties in the superficial subsurface layer (<15µm deep). There was no significant difference in nanohardness and Young's modulus between lased subsurface dentin and untreated dentin (p > 0.05) under the depth of 15µm. However, the dentin at 5µm and 10µm depth beneath the lased surface exhibited significantly lower (~ 47.8% and ~ 33.6% respectively) hardness (p < 0.05). Er:YAG laser irradiation affected both mineral and organic components in subsurface dentin layer, a higher degree of crystallinity and reduced organic compounds occurred in the lased subsurface dentin. CONCLUSION Under the tested laser parameters, Er:YAG laser irradiation causes lower mechanical values and reduction of organic components in subsurface dentin, which has deleterious effects on resin adhesion to this area.
Collapse
Affiliation(s)
- Zhengdi He
- Shenzhen Key Laboratory of Laser Engineering, College of Optoelectronic Engineering, Shenzhen University, Nanhai Road 3688, Shenzhen, Guangdong 518060, China.
| | - Lingling Chen
- Shenzhen Key Laboratory of Laser Engineering, College of Optoelectronic Engineering, Shenzhen University, Nanhai Road 3688, Shenzhen, Guangdong 518060, China.
| | - Xuejuan Hu
- Shenzhen Key Laboratory of Laser Engineering, College of Optoelectronic Engineering, Shenzhen University, Nanhai Road 3688, Shenzhen, Guangdong 518060, China.
| | - Yasushi Shimada
- Cariology and Operative Dentistry, Department of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan.
| | - Masayuki Otsuki
- Cariology and Operative Dentistry, Department of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan.
| | - Junji Tagami
- Cariology and Operative Dentistry, Department of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan.
| | - Shuangchen Ruan
- Shenzhen Key Laboratory of Laser Engineering, College of Optoelectronic Engineering, Shenzhen University, Nanhai Road 3688, Shenzhen, Guangdong 518060, China.
| |
Collapse
|
32
|
Chowdhury SR, Marques MM, Franzen R, Pedroni ACF, Trevelin LT, Abe GL, Gutknecht N. Comparative ultrastructural analysis of Er:YAG laser scanner and conventional method for tooth cavity preparation. ACTA ACUST UNITED AC 2017. [DOI: 10.1007/s41547-017-0003-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
33
|
The effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depths. Lasers Med Sci 2017; 32:967-974. [PMID: 28357598 PMCID: PMC5486492 DOI: 10.1007/s10103-017-2194-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Accepted: 03/14/2017] [Indexed: 11/20/2022]
Abstract
The aim of this study was to evaluate the effect of Er:YAG laser irradiation on the micro-shear bond strength of self-etch adhesives to the superficial dentin and the deep dentin before and after thermocycling. Superficial dentin and deep dentin surfaces were prepared by flattening of the occlusal surfaces of extracted human third molars. The deep or superficial dentin specimens were randomized into three groups according to the following surface treatments: group I (control group), group II (Er:YAG laser; 1.2 W), and group III (Er:YAG laser; 0.5 W). Clearfil SE Bond or Clearfil S3 Bond was applied to each group’s dentin surfaces. After construction of the composite blocks on the dentin surface, the micro-shear bond testing of each adhesive was performed at 24 h or after 15,000 thermal cycles. The data were analyzed using a univariate analysis of variance and Tukey’s test (p < 0.05). Laser irradiation in superficial dentin did not significantly affect bond strength after thermocycling (p > 0.05). However, deep-dentin specimens irradiated with laser showed significantly higher bond strengths than did control specimens after thermocycling (p < 0.05). Thermocycling led to significant deterioration in the bond strengths of all deep-dentin groups. The stable bond strength after thermocycling was measured for all of the superficial-dentin groups. No significant difference was found between the 0.5 and 1.2 W output power settings. In conclusion, the effect of laser irradiation on the bond strength of self-etch adhesives may be altered by the dentin depth. Regardless of the applied surface treatment, deep dentin showed significant bond degradation.
Collapse
|
34
|
He Z, Chen L, Shimada Y, Tagami J, Ruan S. Evaluation of sub-surface penetration and bonding durability of self-etching primer systems to Er:YAG laser treated cervical dentin. Dent Mater J 2017; 36:174-181. [PMID: 28090034 DOI: 10.4012/dmj.2016-216] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study aimed to investigate self-etching bonding systems penetrating in sub-surface dentin layer after Er:YAG laser irradiation and micro-shear bonding durability over a period of 1 year. Dentin slices obtained from extracted human third molars were prepared. Two self-etching adhesive systems were evaluated: Clearfil SE Bond and Clearfil Tri-S Bond. Specimens were tested for micro-shear bond strength with one of the following treatments: Er:YAG laser irradiation and 600-grit silicon paper polishing at 24 h, 7 days, 6 months and 1 year. The adhesive interfaces between bonding agents and lased cervical dentin were studied. No hybrid layer could be observed for lased dentin. The slim resin tags could be seen penetrating through the lased subsurface layer. Bond strength to lased dentin after 6 months and 1 year were significantly decreased (p<0.05).
Collapse
Affiliation(s)
- Zhengdi He
- Shenzhen Key Laboratory of Laser Engineering, College of Optoelectronic Engineering, Shenzhen University
| | | | | | | | | |
Collapse
|
35
|
Synarellis A, Kouros P, Koulaouzidou E, Strakas D, Koliniotou-Koumpia E. In vitro microleakage of class v composite restorations prepared by Er,Cr:YSGG laser and carbide bur. BALKAN JOURNAL OF DENTAL MEDICINE 2017. [DOI: 10.1515/bjdm-2017-0004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Background: The aim of this in vitro study was to compare the degree of microleakage on enamel and dentin margins of class V cavities prepared with either a high-speed drill or an Er,Cr:YSGG laser (2780 nm) and to associate their use with a beveling method for the margin. Method and Materials: Sixty bovine incisors were randomly distributed into three groups. Group 1 (G1) cavities were laser prepared and bur beveled, group 2 (G2) cavities were bur prepared and beveled, while cavities of group 3 (G3) were laser prepared and beveled. Cavities were restored with selective enamel etching, using the same bonding agent and nano-hybrid resin composite for all groups. After thermocycling, microleakage was assessed using a methylene blue dye penetration method. Results: Statistical analysis (Mann-Whitney, Kruskal-Wallis and post-hoc Dunn’s multiple comparison tests) demonstrated significantly higher microleakage for dentin compared to enamel margins in G1. Enamel margin microleakage was found to be significantly higher at G3 compared to G1 (p=0.032) and G2 (p=0.001), while no significant differences were found between G1 and G2 (p=0.850). Regarding dentin margins, G2 group performed significantly better than G1 and G3 (p<<0.001), while there was no significant difference among G1 and G3 scores (p=1.000). Conclusions: The conventional cavity preparation method seems to perform better in terms of microleakage than the Er,Cr;YSGG laser. Laser-prepared cavities could perform better in terms of microleakage if an additional step of enamel bur-beveling is performed prior to restoration.
Collapse
|
36
|
Correa BC, Galo R, Scatena C, Borsatto MC, Spazzin AO, Corona SAM, Galafassi D. Effect of Metalloproteinase Inhibitors on the Microtensile Bond Strength of Composite Resin to Er:YAG Laser-Irradiated Dentin. Braz Dent J 2016; 27:442-5. [DOI: 10.1590/0103-6440201600825] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Accepted: 05/17/2016] [Indexed: 11/21/2022] Open
Abstract
Abstract This study evaluated the effect of matrix metalloproteinase (MMP) inhibitors - 2% (CHX) and sodium fluoride (NaF) (5000 ppm) - on microtensile bond strength (μTBS) of composite resin to Er:YAG laser-irradiated dentin after chemical degradation of the bond interface. The occlusal surface of forty sound human molars was removed exposing the dentin surface (n=10), which was polished, irradiated with Er:YAG laser, acid etched and dried. Twenty specimens were rewetted with 2% CHX (control group) and 20 were rewetted with NaF (5000 ppm). The adhesive system was applied and a 4-mm-high plateau of light-cured composite resin was built up. Resin-dentin sticks were obtained with a rectangular cross-sectional area (0.8-1 mm2) and were either stored in water at 37 ?#61616;C for 24 h or submitted to chemical degradation. For chemical degradation, they were immersed in 10% NaOCl aqueous solution for 5 h and rinsed in water for 1 h. The sticks were submitted to microtensile test in a mechanical testing machine at 0.5 mm/min until failure. Fracture pattern was analyzed using SEM. μTBS values were calculated in MPa and submitted to analysis of variance ANOVA (α=0.05). The variance analysis showed that the 'MMP inhibitor' and 'degradation' factors (p=0.214 and p=0.093, respectively) and interaction between the factors were not statistically significant (p=0.143). Mixed failure predominated in all groups. In conclusion, the 2% CHX and NaF 5000 ppm presented similar μTBS of composite resin to laser-irradiated dentin before and after chemical degradation
Collapse
|
37
|
Galafassi D, Scatena C, Galo R, Curylofo-Zotti FA, Corona SAM, Borsatto MC. Clinical evaluation of composite restorations in Er:YAG laser-prepared cavities re-wetting with chlorhexidine. Clin Oral Investig 2016; 21:1231-1241. [PMID: 27376544 DOI: 10.1007/s00784-016-1897-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Accepted: 06/27/2016] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The objective of this study was to evaluate longitudinally the composite restorations, performed in cavities prepared by Er:YAG or conventional bur, and dentin re-wetting with water or chlorhexidine. MATERIALS AND METHODS Twenty individuals with four active caries with cavitation reaching the dentin located on the occlusal surface of molars counterparts are selected. The teeth of each individual were randomly assigned into four groups: (I) Er:YAG laser (260 mJ/4 Hz) re-wetting with chlorhexidine, (II) Er:YAG laser (260 mJ/4 Hz) re-wetting with deionized water, (III) conventional method re-wetting with chlorhexidine, and (IV) conventional method re-wetting with deionized water. The teeth were isolated, prepared cavities, phosphoric acid etching, and re-wetting according to previously assigned method. Restoration was performed employing the Single Bond 2 and Z350XT resin. Clinical follow-up was held after the polishing of the restoration (baseline) and 6 and 12 months of the making of the restoration using the modified USPHS criteria. The restorations were qualitatively analyzed by means of photographs. In the evaluation period, replicas of the restorations were analyzed by SEM. Data were analyzed by statistics using chi-square test (p < 0.05). RESULTS After 12 months of clinical evaluation, groups prepared with laser and re-wetting with chlorhexidine and water showed the lowest marginal staining value. There was no statistical difference between the groups for other factors. SEM analysis revealed that a non-expressive amount of restorations showed gaps and irregularities of tooth-restoration interface after 6 and 12 months compared to the baseline. CONCLUSION The restorations performed in laser-prepared cavities, regardless of the re-wetting, presented the best clinical performance over the evaluated period. CLINICAL RELEVANCE Laser-prepared teeth, regardless of re-wetting, showed greater resistance to marginal discoloration.
Collapse
Affiliation(s)
- Daniel Galafassi
- Department of Restorative Dentistry, School of Dentistry, Meridional College-IMED, Senador Pinheiro, 304, Cruzeiro, Passo Fundo, Rio Grande do Sul, RS, 99070-220, Brazil
| | - Camila Scatena
- Department of Pediatric Dentistry, School of Dentistry, Serra Gaucha College-FSG, Os Dezoito do Forte 2366, São Pelegrino, Caxias do Sul, Rio Grande do Sul, RS, 95020-472, Brazil
| | - Rodrigo Galo
- Dentistry Department, Federal University of Jequitinhonha and Mucuri Valleys, Diamantina, MG, Brazil
| | - Fabiana Almeida Curylofo-Zotti
- Restorative Dentistry Department, Ribeirão Preto School of Dentistry, São Paulo University, Café Avenue, Monte Alegre, Ribeirão Preto, SP, 14040-904, Brazil
| | - Silmara Aparecida Milori Corona
- Restorative Dentistry Department, Ribeirão Preto School of Dentistry, São Paulo University, Café Avenue, Monte Alegre, Ribeirão Preto, SP, 14040-904, Brazil
| | - Maria Cristina Borsatto
- Clinical Pediatric Dentistry Department, Ribeirão Preto School of Dentistry, São Paulo University, Café Avenue, s/n, Monte Alegre, Ribeirão Preto, SP, 14040-904, Brazil.
| |
Collapse
|
38
|
Bonding Strategies of Resin Cement to Er, Cr:YSGG Lased Dentin: Micro-CT Evaluation and Microshear Bond Strength Testing. Int J Artif Organs 2016; 39:72-6. [DOI: 10.5301/ijao.5000483] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/01/2016] [Indexed: 11/20/2022]
Abstract
Aims Pretreatment of the tooth surface is essential for establishing effective micromechanical retention between it and the restoration. The purpose of this study was to evaluate the bond strength between the resin and the Er, Cr:YSGG laser irradiated dentin and to examine morphologic characterization of the dentin-resin interface. In addition, the study evaluated the quantity of opened and closed dentinal tubules. Subjects and Methods Thirty extracted human molars were sectioned into samples of 1 mm thickness. The samples were randomly assigned to two groups containing 15 specimens each. Surface treatments were not applied to the samples in the control group and the samples in the experimental group were irradiated with an Er,Cr:YSGG laser. Two resin cement samples were polymerized on the surface of each sliced dentin. The micro-shear bond strength (μSBS) between dentin and cement (n = 30 for each group) was measured with a universal testing machine. The topography and morphology of the resin-dentin interface were evaluated by micro-CT (n = 20 for each group). The areas of closed tubular space, closed porosity, area of open tubular space, open porosity, total area of tubular space and fractal dimension were investigated by micro-CT. Statistical analysis used: The data for each parameter were analyzed by Shapiro-Wilk and Student's t test (p<0.05). Results μSBS values for control group were higher than experimental group. Dentin surfaces in the control group revealed less closed and more opened dentin tubules compared to the experimental group. Total area of tubular space was found to have decreased due to the laser ablation. There was no significant difference between the fractal dimensions of the control and experimental groups. Conclusions The lased dentin surface was not favorable for the bonding mechanism due to alterations in the dentinal structure.
Collapse
|
39
|
Trelles K, Arnabat J, España-Tost T. Microleakage in Class V cavities with self-etching adhesive system and conventional rotatory or laser Er,Cr:YSGG. Laser Ther 2014; 21:255-68. [PMID: 24511195 DOI: 10.5978/islsm.12-or-14] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2012] [Accepted: 10/06/2012] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To analyse microleakage in Class V cavity preparation with Er;Cr:YSGG at different parameters using a self-etching adhesive system. BACKGROUND Several studies reported microleakage around composite restorations when cavity preparation is done or treated by Er;Cr:YSGG laser. We want to compare different energy densities in order to obtain the best parameters, when using a self-etching adhesive system. METHODS A class V preparations was performed in 120 samples of human teeth were divided in 3 groups: (1) Preparation using the burr. (2) Er;Cr:YSGG laser preparation with high energy 4W, 30 Hz, 50% Water 50% Air and (3) Er;Cr:YSGG laser preparation lower energy 1.5 W, 30 Hz, 30% Water 30% Air. All the samples were restored with self-etching adhesive system and hybrid composite. Thermocycling (5000 cycles) and immersed in 0.5% fuchsin. The restorations were sectioned and evaluated the microleakage with a stereomicroscope. RESULTS Lower energy laser used for preparation showed significant differences in enamel and dentin. To group 3, the microleakage in the enamel was less, whilst the group 1, treated with the turbine, showed less microleakage at dentin level. Group 2 showed the highest microleakage at dentin/cement level. CONCLUSION Burr preparation gives the lowest microleakage at cement/dentin level, whilst Er;Cr:YSGG laser at lower power has the low energy obtains lowest microleakage at enamel. On the contrary high-energy settings produce inferior results in terms of microleakage.
Collapse
Affiliation(s)
- K Trelles
- Trelles K, Faculty of Dentistry, Department of Odontostomatology, University of Barcelona, Spain
| | - J Arnabat
- Arnabat J, Faculty of Dentistry, Department of Odontostomatology, University of Barcelona, Spain
| | - T España-Tost
- España-Tost T, Department of Odontostomatology, University of Barcelona, Spain
| |
Collapse
|
40
|
Juntavee A, Juntavee N, Peerapattana J, Nualkaew N, Sutthisawat S. Comparison of Marginal Microleakage of Glass Ionomer Restorations in Primary Molars Prepared by Chemo-mechanical Caries Removal (CMCR), Erbium: Yttrium Aluminum-Garnet (Er:YAG) Laser and Atraumatic Restorative Technique (ART). Int J Clin Pediatr Dent 2013; 6:75-9. [PMID: 25206196 PMCID: PMC4086587 DOI: 10.5005/jp-journals-10005-1193] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Accepted: 06/25/2013] [Indexed: 11/23/2022] Open
Abstract
Background: It is important to emphasize that the aspects of pretreatment techniques, as well as the composition and mechanism of adhesion, may decisively influence the effectiveness of the restorative materials in sealing cavity margins and preventing marginal leakage. Aims: This study assessed the in vitro influence of surface preparation techniques on the microleakage of glass ionomer restorations in primary teeth. Materials and methods: The study groups were divided into three different techniques: (1) The chemomechanical caries removal (CMCR) method using the Apacaries gel, (2) the erbium:yttrium aluminum-garnet (Er:YAG) laser method and (3) the atraumatic restorative technique (ART). The teeth restored with a glass ionomer restorative material (Fuji IX GP capsule, GC Corporation, Tokyo, Japan). The dye penetration was measured in micrometers using a polarized light microscope and specific computer software. Results: The results showed that the mean microleakage level after was lowest with the CMCR method using Apacaries gel and highest with the Er:YAG laser. There was a statistically significant difference regarding the mean microleakage level between the group with the CMCR method using Apacaries gel and the Er:YAG laser. Conclusion: Marginal leakage was significantly higher with preparations made using the Er:YAG laser than with the CMCR method using Apacaries gel and spoon excavator (p < 0.05). How to cite this article: Juntavee A, Juntavee N, Peerapattana J, Nualkaew N, Sutthisawat S. Comparison of Marginal Microleakage of Glass Ionomer Restorations in Primary Molars Prepared by Chemomechanical Caries Removal (CMCR), Erbium: Yttrium Aluminum-Garnet (Er:YAG) Laser and Atraumatic Restorative Technique (ART). Int J Clin Pediatr Dent 2013;6(2):75-79.
Collapse
Affiliation(s)
- Apa Juntavee
- Associate Professor, Department of Pediatric Dentistry, Faculty of Dentistry, Khon Kaen University, Thailand, e-mail:
| | - Niwut Juntavee
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Thailand
| | - Jomjai Peerapattana
- Associate Professor, Department of Pharmaceutical Technology Faculty of Pharmaceutical Sciences, Khon Kaen University, Thailand
| | - Nartsajee Nualkaew
- Lecturer, Department of Pharmacognosy and Toxicology, Faculty of Pharmaceutical Sciences, Khon Kaen University, Thailand
| | - Sitikorn Sutthisawat
- Dental Student, Department of Pediatric Dentistry, Faculty of Dentistry, Khon Kaen University, Thailand
| |
Collapse
|
41
|
da Silva MA, Di Nicolo R, Barcellos DC, Batista GR, Pucci CR, Rocha Gomes Torres C, Borges AB. Influence of CVD diamond tips and Er:YAG laser irradiation on bonding of different adhesive systems to dentin. J Contemp Dent Pract 2013; 14:14-20. [PMID: 23579886 DOI: 10.5005/jp-journals-10024-1262] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
AIM The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. MATERIALS AND METHODS A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm(2). The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). RESULTS AND CONCLUSION Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. CLINICAL SIGNIFICANCE Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.
Collapse
Affiliation(s)
- Melissa Aline da Silva
- Department of Restorative Dentistry, Clinical Research Academic Group, Sao Jose dos Campos School of Dentistry, Sao Paulo State University, UNESP, Brazil
| | | | | | | | | | | | | |
Collapse
|
42
|
Brulat N, Fornaini C, Rocca JP, Darque-Ceretti E. Role of surface tension and roughness on the wettability of Er:YAG laser irradiated dentin: In vitro study. Laser Ther 2013. [DOI: 10.5978/islsm.13-or-15] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
43
|
Oskoee PA, Kimyai S, Ebrahimi ME, Rikhtegaran S, Pournaghi-Azar F. Cervical Margin Integrity of Class II Resin Composite Restorations in Laser- and Bur-Prepared Cavities Using Three Different Adhesive Systems. Oper Dent 2012; 37:316-23. [DOI: 10.2341/10-403-l] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
One of the challenges in durability of posterior tooth-colored restorative materials is polymerization shrinkage, which results in gap formation between the restoration and tooth structure. The aim of the present study was to investigate marginal adaptation of Class II composite restorations using a self-etching and two etch-and-rinse adhesive systems in cavities prepared either with bur or Er,Cr:YSGG laser. A total of 45 extracted sound human premolars were selected. In each tooth, mesial and distal Class II cavities were prepared either by a diamond bur or by Er,Cr:YSGG laser with the margins 1 mm apical to the cemento-enamel junction. Then the teeth were randomly divided into three groups of 15 each, according to the type of the adhesive system used (Single Bond, Single Bond 2, and Adper Easy One adhesive systems). Subsequent to restoring the teeth, the specimens were subjected to thermal cycling between 5 ± 2°C and 55 ± 2°C for 500 cycles and were then cut longitudinally into two halves using a diamond disk. Marginal adaptation was evaluated using a stereomicroscope, and the values for gap widths were obtained in micrometers. Data were analyzed using two-factor analysis of variance and post hoc tests. There were statistically significant differences in mean marginal gap widths between the adhesive type and preparation groups (p<0.05). The interfacial gap width in bur-prepared cavities was significantly less than that in laser-prepared cavities, and the lowest gap width was observed in Adper Easy One regardless of the type of the preparation.
Collapse
|
44
|
Adebayo OA, Burrow MF, Tyas MJ, Palamara J. Effect of Tooth Surface Preparation on the Bonding of Self-Etching Primer Adhesives. Oper Dent 2012; 37:137-49. [DOI: 10.2341/11-172-l] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
The effectiveness of some self-etching primer adhesive systems is not significantly affected by the mode of rotary instrumentation used in dentin preparation.
Collapse
|
45
|
de Oliveira MT, Arrais CAG, Aranha AC, de Paula Eduardo C, Miyake K, Rueggeberg FA, Giannini M. Micromorphology of resin-dentin interfaces using one-bottle etch&rinse and self-etching adhesive systems on laser-treated dentin surfaces: a confocal laser scanning microscope analysis. Lasers Surg Med 2011; 42:662-70. [PMID: 20806391 DOI: 10.1002/lsm.20945] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVES This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. STUDY DESIGN Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S(3) Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate-dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. RESULTS Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. "Stretch mark"-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. CONCLUSION Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study.
Collapse
Affiliation(s)
- Marcelo Tavares de Oliveira
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, SP 13414-903, Brazil
| | | | | | | | | | | | | |
Collapse
|
46
|
Morphological changes in hard dental tissues prepared by Er:YAG laser (LiteTouch, Syneron), Carisolv and rotary instruments. A scanning electron microscopy evaluation. Folia Med (Plovdiv) 2010; 52:46-55. [PMID: 21053673 DOI: 10.2478/v10153-010-0006-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
AIM This in vitro investigation aimed to study by means of scanning electron microscope the morphological changes in hard dental tissues after using several different methods for caries removal and cavity preparation. MATERIALS AND METHODS Twenty freshly extracted human teeth with carious lesions were used in the study. They were assigned to four groups depending on the method used for preparation: Group 1--Cavity preparation using Er: YAG laser (LiteTouch, Syneron, Israel). Group 2--Chemomechanical preparation using colourless Carisolv gel (MediTeam AB, Savedalen, Sweden). Group 3--Mechanical rotary preparation using diamond burs and air turbine. Group 4--Mechanical rotary preparation using by steel burs and micromotor. The preparations were performed strictly according to the manufacturer's instructions for proper use of instruments. The teeth samples were prepared for histological study and investigated by a scanning electron microscope at different magnification; the morphological changes in the tissues were registered and compared. RESULTS There were considerable differences in the surface characteristics of the dental tissues when we analysed the photomicrographs of the specimens obtained using scanning electron microscopy (SEM). The surface after laser treatment remained highly retentive with no residual smear layer; the second best results in this respect were registered when teeth were chemomechanically excavated with Carisolv gel. The mechanical methods of cavity preparation resulted in surfaces with a smear layer of dentin without any microretentions. CONCLUSION The scanning electron microscopy of hard dental tissues prepared using steel and diamond burs showed surfaces covered with a thick smear layer that may be relevant to the subsequent bonding of adhesive restorative materials to the prepared cavity. In preparing the surface using a turbine with diamond burs the smear layer was thinner and part of the dentinal tubules orifices were open in the area of water turbulence. SEM analysis of hard dental tissues prepared with the help of colourless Carisolv gel showed a rough, retentive surface, some of the dentinal tubule lumens obstructed by denaturated collagen and surface contaminants. The teeth surfaces prepared with Er:YAG laser Lite Touch (Syneron) remained without smear layer and clearly exposed dentinal tubules orifices. The surfaces were highly retentive.
Collapse
|
47
|
Adu-Arko AY, Sidhu SK, McCabe JF, Pashley DH. Effect of an Er,Cr:YSGG laser on water perfusion in human dentine. Eur J Oral Sci 2010; 118:483-8. [DOI: 10.1111/j.1600-0722.2010.00768.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
48
|
Chousterman M, Heysselaer D, Dridi SM, Bayet F, Misset B, Lamard L, Peremans A, Nyssen-Behets C, Nammour S. Effect of acid etching duration on tensile bond strength of composite resin bonded to erbium:yttrium-aluminium-garnet laser-prepared dentine. Preliminary study. Lasers Med Sci 2009; 25:855-9. [PMID: 19685196 DOI: 10.1007/s10103-009-0719-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2009] [Accepted: 07/15/2009] [Indexed: 11/25/2022]
Abstract
The purpose of this study was to compare the tensile bond strength of composite resin bonded to erbium:yttrium-aluminium-garnet (Er:YAG) laser-prepared dentine after different durations of acid etching. The occlusal third of 68 human third molars was removed in order to expose the dentine surface. The teeth were randomly divided into five groups: group B (control group), prepared with bur and total etch system with 15 s acid etching [37% orthophosphoric acid (H(3)PO(4))]; group L15, laser photo-ablated dentine (200 mJ) (laser irradiation conditions: pulse duration 100 micros, air-water spray, fluence 31.45 J/ cm(2), 10 Hz, non-contact hand pieces, beam spot size 0.9 mm, irradiation speed 3 mm/s, and total irradiation time 2 x 40 s); group L30, laser prepared, laser conditioned and 30 s acid etching; group L60, laser prepared, laser conditioned and 60 s acid etching; group L90, laser prepared, laser conditioned and 90 s acid etching. A plot of composite resin was bonded onto each exposed dentine and then tested for tensile bond strength. The values obtained were statistically analysed by analysis of variance (ANOVA) coupled with the Tukey-Kramer test at the 95% level. A 90 s acid etching before bonding showed the best bonding value (P < 0.05) when compared with all the other groups including the control group. There is no significance difference between other groups, nor within each group and the control group. There was a significant increase in tensile bond strength of the samples acid etched for 90 s.
Collapse
Affiliation(s)
- M Chousterman
- Department of Dental Sciences, Faculty of Medicine, University of Liege, Quai Godfroid Kurth, 45, 4000, Liege, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Krmek SJ, Bogdan I, Simeon P, Mehicić GP, Katanec D, Anić I. A three-dimensional evaluation of microleakage of class V cavities prepared by the very short pulse mode of the erbium:yttrium-aluminium-garnet laser. Lasers Med Sci 2009; 25:823-8. [PMID: 19593602 DOI: 10.1007/s10103-009-0707-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2009] [Accepted: 06/12/2009] [Indexed: 11/29/2022]
Abstract
The aim of this study was to evaluate microleakage along resin restoration in cavities prepared with an erbium:yttrium-aluminium-garnet (Er:YAG) laser, with and without acid etching, and to compare it with that in diamond-drilled cavities. Thirty intact molars were divided into three equal groups. In the teeth in group I, class V cavities were prepared with a diamond drill. Cavities in groups II and III were prepared with an Er:YAG laser (400 mJ/15 Hz for enamel and 250 mJ/10 Hz for dentine). The cavities in groups I and II were acid-etched and adhesive and flowable composite were applied to all cavities. The specimens were first immersed in dye for 24 h and then in 5% nitric acid for 72 h for softening. The fillings were extracted and photographed through a dissecting microscope. The leakage area was measured with specially designed software. The Kruskal-Wallis test showed that the best ranking was group II [mean range (m.r.) = 27.46], followed by group I (m.r. = 33.48) and, lastly, group III (m.r. = 45.15). The differences between groups I and III (P = 0.023) and between groups II and III were statistically significant (P = 0.080). The least microleakage was found in those cavities prepared by Er:YAG laser and subsequently acid-etched, whereas the most leakage was in the lased cavities that had not been etched; the traditional diamond-drilled acid-etched cavities produced medium leakage.
Collapse
Affiliation(s)
- Silvana Jukić Krmek
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000, Zagreb, Croatia.
| | | | | | | | | | | |
Collapse
|
50
|
Obeidi A, McCracken MS, Liu PR, Litaker MS, Beck P, Rahemtulla F. Enhancement of bonding to enamel and dentin prepared by Er,Cr:YSGG laser. Lasers Surg Med 2009; 41:454-62. [DOI: 10.1002/lsm.20790] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|