1
|
Li H, Cong Y. Past and Recent Progress on Metallic Digestive Tract Stents. ACS APPLIED BIO MATERIALS 2024; 7:7088-7100. [PMID: 39500551 DOI: 10.1021/acsabm.4c00823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2024]
Abstract
The implantation of digestive tract stents at various lesion sites can effectively improve digestive tract patency, opening up an excellent treatment method for diseases that are currently incurable or resistant to conventional surgery. Digestive tract stents have been extensively studied and widely used worldwide due to their unique advantages of simple implantation, low trauma, satisfactory effect, and low complication rate. Among the various types of stents, metallic stents have been developed to improve surgical efficacy due to their excellent mechanical properties and are constantly being improved. This review provides an overview of the design and development of conventional nonbiodegradable metallic digestive tract stents such as nitinol (NiTi alloy), stainless steel, and cobalt-based alloy stents. Furthermore, biodegradable metallic stents for the digestive tract, such as magnesium-based, iron-based, and zinc-based stents, are described. This paper also evaluates the advantages and disadvantages of existing metallic digestive stents as well as future research directions and challenges in the development of metallic digestive tract stents.
Collapse
Affiliation(s)
- Huafang Li
- School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Yu Cong
- School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083, China
| |
Collapse
|
2
|
Bedair TM, Heo Y, Ryu J, Bedair HM, Park W, Han DK. Biocompatible and functional inorganic magnesium ceramic particles for biomedical applications. Biomater Sci 2021; 9:1903-1923. [PMID: 33506843 DOI: 10.1039/d0bm01934h] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Magnesium ceramics hold promise for numerous biological applications. This review covers the synthesis of magnesium ceramic particles with specific morphologies and potential modification techniques. Magnesium ceramic particles possess multiple characteristics directly applicable to human biology; they are anti-inflammatory, antibacterial, antiviral, and offer anti-cancer effects. Based on these advantages, magnesium hydroxide nanoparticles have been extensively utilized across biomedical fields. In a vascular stent, the incorporation of magnesium ceramic nanoparticles enhances re-endothelialization. Additionally, tissue regeneration for bone, cartilage, and kidney can be promoted by magnesium ceramics. This review enables researchers to identify the optimum synthetic conditions to prepare magnesium ceramics with specific morphologies and sizes and select the appropriate modification protocols. It is also intended to elucidate the desirable physicochemical properties and biological benefits of magnesium ceramics.
Collapse
Affiliation(s)
- Tarek M Bedair
- Department of Biomedical Science, CHA University, 335 Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi 13488, Korea.
| | | | | | | | | | | |
Collapse
|
3
|
Han G, Bedair TM, Kim DH, Park KH, Park W, Han DK. Improved mechanical and biological properties of biodegradable thinner poly(l-lactic acid) tubes by bi-directional drawing. J IND ENG CHEM 2020. [DOI: 10.1016/j.jiec.2020.06.029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
4
|
Covalent immobilization of fibroblast-derived matrix on metallic stent for expeditious re-endothelialization. J IND ENG CHEM 2019. [DOI: 10.1016/j.jiec.2018.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
5
|
Bedair TM, Min IJ, Park W, Joung YK, Han DK. Sustained drug release using cobalt oxide nanowires for the preparation of polymer-free drug-eluting stents. J Biomater Appl 2018; 33:352-362. [PMID: 30223735 DOI: 10.1177/0885328218792141] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Polymer-based drug-eluting stents (DESs) represented attractive application for the treatment of cardiovascular diseases; however, polymer coating has caused serious adverse responses to tissues such as chronic inflammation due to acidic by-products. Therefore, polymer-free DESs have recently emerged as promising candidates for the treatment; however, burst release of drug(s) from the surface limited its applications. In this study, we focused on delivery of therapeutic drug from polymer-free (or -less) DESs through surface modification using cobalt oxide nanowires (Co3O4 NWs) to improve and control the drug release. The results demonstrated that Co3O4 NWs could be simply fabricated on cobalt-chromium substrate by ammonia-evaporation-induced method. The Co3O4 NWs were uniformly arrayed with diameters of 50-100 nm and lengths of 10 µm. It was found that Co3O4 NWs were comparatively stable without any delamination or change of the morphology under in vitro long-term stability using circulating system. Sirolimus was used as a model drug for studying in vitro release behavior under physiological conditions. The sirolimus release behavior from flat cobalt-chromium showed an initial burst (over 90%) after one day. On the other hand, Co3O4 NWs presented a sustained sirolimus release rate for up to seven days. Similarly, the polymer-less specimens on Co3O4 NWs substrates sustained sirolimus release for a longer-period of time when compared to flat Co-Cr substrates. In summary, the current approach of using Co3O4 NWs-based substrates might have a great potential to sustain drug release for drug-eluting implants and medical devices including stents.
Collapse
Affiliation(s)
- Tarek M Bedair
- 1 Department of Biomedical Science, CHA University, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi, Republic of Korea.,2 Chemistry Department, Faculty of Science, Minia University, El-Minia, Egypt.,3 Center for Biomaterials, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Il Jae Min
- 3 Center for Biomaterials, Korea Institute of Science and Technology, Seoul, Republic of Korea
| | - Wooram Park
- 1 Department of Biomedical Science, CHA University, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi, Republic of Korea
| | - Yoon Ki Joung
- 3 Center for Biomaterials, Korea Institute of Science and Technology, Seoul, Republic of Korea.,4 Department of Biomedical Engineering, Korea University of Science and Technology, Daejeon, Republic of Korea
| | - Dong Keun Han
- 1 Department of Biomedical Science, CHA University, Pangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi, Republic of Korea
| |
Collapse
|
6
|
Dual-Layer Coated Drug-Eluting Stents with Improved Degradation Morphology and Controlled Drug Release. Macromol Res 2018. [DOI: 10.1007/s13233-018-6110-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
7
|
Kim JH, Shin SS, Noh HS, Son JW, Choi M, Kim H. Tailoring ceramic membrane structures of solid oxide fuel cells via polymer-assisted electrospray deposition. J Memb Sci 2017. [DOI: 10.1016/j.memsci.2017.09.027] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
8
|
Bedair TM, ElNaggar MA, Joung YK, Han DK. Recent advances to accelerate re-endothelialization for vascular stents. J Tissue Eng 2017; 8:2041731417731546. [PMID: 28989698 PMCID: PMC5624345 DOI: 10.1177/2041731417731546] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2017] [Accepted: 08/19/2017] [Indexed: 12/25/2022] Open
Abstract
Cardiovascular diseases are considered as one of the serious diseases that leads to the death of millions of people all over the world. Stent implantation has been approved as an easy and promising way to treat cardiovascular diseases. However, in-stent restenosis and thrombosis remain serious problems after stent implantation. It was demonstrated in a large body of previously published literature that endothelium impairment represents a major factor for restenosis. This discovery became the driving force for many studies trying to achieve an optimized methodology for accelerated re-endothelialization to prevent restenosis. Thus, in this review, we summarize the different methodologies opted to achieve re-endothelialization, such as, but not limited to, manipulation of surface chemistry and surface topography.
Collapse
Affiliation(s)
- Tarek M Bedair
- Center for Biomaterials, Korea Institute of Science and Technology (KIST), Seoul, Korea
- Chemistry Department, Faculty of Science, Minia University, Minia, Egypt
| | - Mahmoud A ElNaggar
- Center for Biomaterials, Korea Institute of Science and Technology (KIST), Seoul, Korea
- Department of Biomedical Engineering, Korea University of Science and Technology, Daejeon, Korea
| | - Yoon Ki Joung
- Center for Biomaterials, Korea Institute of Science and Technology (KIST), Seoul, Korea
- Department of Biomedical Engineering, Korea University of Science and Technology, Daejeon, Korea
| | - Dong Keun Han
- Center for Biomaterials, Korea Institute of Science and Technology (KIST), Seoul, Korea
- Department of Biomedical Engineering, Korea University of Science and Technology, Daejeon, Korea
- Department of Biomedical Science, CHA University, Gyeonggi, Korea
| |
Collapse
|
9
|
Fabrication and characteristics of dual functionalized vascular stent by spatio-temporal coating. Acta Biomater 2016; 38:143-52. [PMID: 27109766 DOI: 10.1016/j.actbio.2016.04.029] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Revised: 04/14/2016] [Accepted: 04/18/2016] [Indexed: 11/24/2022]
Abstract
UNLABELLED Stent implantation with balloon angioplasty is a widely used treatment for coronary artery diseases. Stents have been developed from bare metal stent (BMS) to advanced forms such as drug-eluting stent (DES). However, modern DES still causes thrombosis and/or in-stent restenosis as long-term outcomes. For effective prevention of these problems, we fabricated a dual functionalized stent using spatio-temporal coating, which has two different surfaces, as a novel type of DES. Hyaluronic acid conjugated with dopamine (HA-DA) was applied to a bare cobalt-chromium (CC) stent prior to abluminal coating of sirolimus (SRL)-in-polymer such as poly(d,l-lactide). The SRL-in-polymer (P+S) coated on the abluminal surface of the HA-DA modified stent showed highly stable coating layer and prevented the crack formation after ballooning. In the blood- and cyto-compatibility tests, HA-DA coating displayed suppressive effects on adhesion and activation of platelets and maintained the cell viability and proliferation of human coronary artery endothelial cells even under the existence of SRL. In in vivo study using porcine restenosis model, the neointimal area and inflammation score of the dual functionalized stent with HA-DA and P+S were significantly reduced than those of BMS. It is expected that this novel type of DES can be effectively applied to utilize diverse anti-proliferative drugs and bioactive polymers. STATEMENT OF SIGNIFICANCE Stents have been developed from bare metal stent to advanced forms such as drug-eluting stents (DESs). However, even DESs can still cause in-stent restenosis as long-term outcomes. This paper demonstrated a novel DES using spatio-temporal coating by dopamine-mediated hyaluronic acid coating (HA-DA) before asymmetric coating of sirolimus-in-poly(d,l-lactide) (P+S). It showed stable coating surface and prevented crack formation after ballooning. HA-DA coating also had an inhibitive effect on adhesion of platelets and maintained cell viability of endothelial cells even under the existence of sirolimus. Additionally, in vivo neointima area and inflammation score of HA-DA/P+S stent significantly decreased than those of BMS. We expected that this novel type of DES can be effectively applied to introduce diverse anti-proliferative drugs and bioactive molecules.
Collapse
|
10
|
Bedair TM, Cho Y, Park BJ, Joung YK, Han DK. Coating defects in polymer-coated drug-eluting stents. BIOMATERIALS AND BIOMECHANICS IN BIOENGINEERING 2014. [DOI: 10.12989/bme.2014.1.3.131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|