1
|
Chen X, Li X, Turco S, van Sloun RJG, Mischi M. Ultrasound Viscoelastography by Acoustic Radiation Force: A State-of-the-Art Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:536-557. [PMID: 38526897 DOI: 10.1109/tuffc.2024.3381529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
Ultrasound elastography (USE) is a promising tool for tissue characterization as several diseases result in alterations of tissue structure and composition, which manifest as changes in tissue mechanical properties. By imaging the tissue response to an applied mechanical excitation, USE mimics the manual palpation performed by clinicians to sense the tissue elasticity for diagnostic purposes. Next to elasticity, viscosity has recently been investigated as an additional, relevant, diagnostic biomarker. Moreover, since biological tissues are inherently viscoelastic, accounting for viscosity in the tissue characterization process enhances the accuracy of the elasticity estimation. Recently, methods exploiting different acquisition and processing techniques have been proposed to perform ultrasound viscoelastography. After introducing the physics describing viscoelasticity, a comprehensive overview of the currently available USE acquisition techniques is provided, followed by a structured review of the existing viscoelasticity estimators classified according to the employed processing technique. These estimators are further reviewed from a clinical usage perspective, and current outstanding challenges are discussed.
Collapse
|
2
|
Mobadersany N, Liang P, Kemper P, Konofagou EE. Polyvinyl Alcohol Phantoms With Heterogeneous Plaques: Estimation of Pulse Wave Velocity at the Stenotic Region Using Pulse Wave Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:91-98. [PMID: 37838523 PMCID: PMC11102764 DOI: 10.1016/j.ultrasmedbio.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 09/01/2023] [Accepted: 09/08/2023] [Indexed: 10/16/2023]
Abstract
OBJECTIVE Plaque characterization is essential for stroke prevention. In the study reported herein, we describe a heterogeneous phantom manufacturing technique with varying plaque compositions of different stiffness using polyvinyl alcohol (PVA) to emulate stenotic arteries and evaluated the use of pulse wave imaging (PWI) to assess plaque stiffness by comparing derived pulse wave velocities, with the goal of assessing plaque vulnerability and identifying high-risk patients for stroke. METHODS Five stenotic phantoms (50% stenosis) were fabricated by pouring PVA solutions into 3-D-printed molds. Two of the phantoms had heterogeneous plaque compositions of soft (E0 = 13 kPa) and intermediate (E0 = 40 kPa) materials and of stiff (E0 = 54 kPa) and intermediate materials. Ultrasound sequences were acquired as the arterial phantoms were connected to a pulsating pump, and PWI was performed on the ultrasound acquisition using normalized cross-correlation to track the pulse-induced phantom wall distension propagations. Pulse wave velocities were estimated by fitting a linear regression line between the arrival time of the peak acceleration of the wall distension waveform and the corresponding location. RESULTS Arterial phantoms with heterogeneous plaque stiffness were successfully fabricated. Pulse wave velocities of 2.06, 2.21, 2.49, 2.67 and 3.31 m/s were found in the phantom experiments using PWI for homogeneous soft plaque, the heterogeneous soft and intermediate plaque, homogeneous intermediate plaque, the heterogeneous stiff and intermediate plaque and homogeneous stiff plaque, respectively. CONCLUSION A novel arterial phantom building technique was reported with varying heterogenous plaque compositions of different stiffness. The feasibility of using PWI to evaluate plaque stiffness in stenotic arteries was determined and found that PWI can distinguish between plaques of distinct stiffness and composition.
Collapse
Affiliation(s)
- Nima Mobadersany
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Pengcheng Liang
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Paul Kemper
- Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, USA; Department of Radiology, Columbia University, New York, New York, NY, USA.
| |
Collapse
|
3
|
Li Z, Luo T, Wang S, Jia H, Gong Q, Liu X, Sutcliffe MPF, Zhu H, Liu Q, Chen D, Xiong J, Teng Z. Mechanical and histological characteristics of aortic dissection tissues. Acta Biomater 2022; 146:284-294. [PMID: 35367380 DOI: 10.1016/j.actbio.2022.03.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/23/2022] [Accepted: 03/24/2022] [Indexed: 12/14/2022]
Abstract
AIMS This study investigated the association between the macroscopic mechanical response of aortic dissection (AoD) flap, its fibre features, and patient physiological features and clinical presentations. METHODS Uniaxial test was performed with tissue strips in both circumferential and longitudinal directions from 35 patients with (AoD:CC) and without (AoD:w/oCC) cerebral/coronary complications, and 19 patients with rheumatic or valve-related heart diseases (RH). A Bayesian inference framework was used to estimate the expectation of material constants (C1, D1, and D2) of the modified Mooney-Rivlin strain energy density function. Histological examination was used to visualise the elastin and collagen in the tissue strips and image processing was performed to quantify their area percentages, fibre misalignment and waviness. RESULTS The elastin area percentage was negatively associated with age (p = 0.008), while collagen increased about 6% from age 40 to 70 (p = 0.03). Elastin fibre was less dispersed and wavier in old patients and no significant association was found between patient age and collagen fibre dispersion or waviness. Features of fibrous microstructures, either elastin or collagen, were comparable between AoD:CC and AoD:w/oCC group. Elastin and collagen area percentages were positively correlated with C1 and D2, respectively, while the elastin and collagen waviness were negatively correlated with C1 and D2, respectively. Elastin dispersion was negatively correlated to D2. Multivariate analysis showed that D2 was an effective parameter which could differentiate patient groups with different age and clinical presentations, as well as the direction of tissue strip. CONCLUSION Fibre dispersion and waviness in the aortic dissection flap changed with patient age and clinical presentations, and these can be captured by the material constants in the strain energy density function. STATEMENT OF SIGNIFICANCE Aortic dissection (AoD) is a severe cardiovascular disease. Understanding the mechanical property of intimal flap is essential for its risk evaluation. In this study, mechanical testing and histology examination were combined to quantify the relationship between mechanical presentations and microstructure features. A Bayesian inference framework was employed to estimate the expectation of the material constants in the modified Mooney-Rivlin constitutive equation. It was found that fibre dispersion and waviness in the AoD flap changed with patient age and clinical presentations, and these could be captured by the material constants. This study firstly demonstrated that the expectation of material constants can be used to characterise tissue microstructures and differentiate patients with different clinical presentations.
Collapse
|
4
|
Li Y, Moon S, Jiang Y, Qiu S, Chen Z. Intravascular polarization-sensitive optical coherence tomography based on polarization mode delay. Sci Rep 2022; 12:6831. [PMID: 35477738 PMCID: PMC9046432 DOI: 10.1038/s41598-022-10709-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Accepted: 04/11/2022] [Indexed: 01/13/2023] Open
Abstract
Intravascular polarization-sensitive optical coherence tomography (IV-PSOCT) provides depth-resolved tissue birefringence which can be used to evaluate the mechanical stability of a plaque. In our previous study, we reported a new strategy to construct polarization-sensitive optical coherence tomography in a microscope platform. Here, we demonstrated that this technology can be implemented in an endoscope platform, which has many clinical applications. A conventional intravascular OCT system can be modified for IV-PSOCT by introducing a 12-m polarization-maintaining fiber-based imaging probe. Its two polarization modes separately produce OCT images of polarization detection channels spatially distinguished by an image separation of 2.7 mm. We experimentally validated our IV-PSOCT with chicken tendon, chicken breast, and coronary artery as the image samples. We found that the birefringent properties can be successfully visualized by our IV-PSOCT.
Collapse
Affiliation(s)
- Yan Li
- Beckman Laser Institute, University of California, Irvine, Irvine, CA, 92617, USA
| | - Sucbei Moon
- Department of Physics, Kookmin University, Seoul, 02707, South Korea
| | - Yuchen Jiang
- Beckman Laser Institute, University of California, Irvine, Irvine, CA, 92617, USA.,Department of Physics, Kookmin University, Seoul, 02707, South Korea
| | - Saijun Qiu
- Beckman Laser Institute, University of California, Irvine, Irvine, CA, 92617, USA.,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697, USA
| | - Zhongping Chen
- Beckman Laser Institute, University of California, Irvine, Irvine, CA, 92617, USA. .,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697, USA. .,The Cardiovascular Innovation and Research Center, University of California, Irvine, , Irvine, CA, 92617, USA.
| |
Collapse
|
5
|
Li Y, Kwong DLW, Wu VWC, Yip SP, Law HKW, Lee SWY, Ying MTC. Computer-assisted ultrasound assessment of plaque characteristics in radiation-induced and non-radiation-induced carotid atherosclerosis. Quant Imaging Med Surg 2021; 11:2292-2306. [PMID: 34079702 DOI: 10.21037/qims-20-1012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Background This study investigated the feasibility of using a computer-assisted method to evaluate and differentiate the carotid plaque characteristics in radiation-induced and non-radiation-induced carotid atherosclerosis. Methods This study included 107 post-radiotherapy (post-RT) nasopharyngeal carcinoma (NPC) patients and 110 subjects with cardiovascular risk factors (CVRFs). Each participant had a carotid ultrasound examination, and carotid plaques and carotid intima-media thickness (CIMT) were evaluated with grey scale ultrasound. The carotid plaque characteristics were evaluated for grey-scale median (GSM) and detailed plaque texture analysis (DPTA) using specific computer software. In DPTA, five different intra-plaque components were colour-coded according to different grey scale ranges. A multivariate linear regression model was used to evaluate the correlation of risk factors and carotid plaque characteristics. Results Post-RT NPC patients have significantly higher CIMT (748±15.1 µm, P=0.001), more patients had a plaque formation (80.4%, P<0.001) and more plaque locations (2.3±0.2, P<0.001) than CVRF subjects (680.4±10.0 µm, 38.2% and 0.5±0.1 respectively). Among the five intra-plaque components, radiation-induced carotid plaques had significantly larger area of calcification (4.8%±7.7%, P=0.012), but lesser area of lipid (42.1%±16.9%, P=0.034) when compared to non-radiation-induced carotid plaques (3.0%±5.7% and 46.3%±17.9% respectively). Age, radiation and number of CVRF were significantly associated with the carotid atherosclerosis burden (P<0.001). Besides, age was significantly associated with the amount of lipid and calcification within carotid plaques (P<0.001). Conclusions Radiation caused more severe carotid artery disease than CVRF with larger CIMT and more prevalent of carotid plaque. Radiation-induced carotid plaques tended to have more intra-plaque calcifications, whereas non-radiation-induced carotid plaques had more lipids. Ultrasound aided by computer-assisted image analysis has potential for more accurate assessment of carotid atherosclerosis.
Collapse
Affiliation(s)
- Yuanxi Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Dora Lai-Wan Kwong
- Department of Clinical Oncology, The University of Hong Kong, Queen Mary Hospital, Hong Kong, China
| | - Vincent Wing-Cheung Wu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Shea-Ping Yip
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Helen Ka-Wai Law
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Shara Wee-Yee Lee
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Michael Tin-Cheung Ying
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
6
|
Zheng Z, Zhao Q, Wei J, Wang B, Wang H, Meng L, Xin Y, Jiang X. Medical prevention and treatment of radiation-induced carotid injury. Biomed Pharmacother 2020; 131:110664. [PMID: 32861067 DOI: 10.1016/j.biopha.2020.110664] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/06/2020] [Accepted: 08/20/2020] [Indexed: 11/30/2022] Open
Abstract
Radiotherapy has significantly improved the survival of cancer patients but is also associated with several adversities, including radiation-induced carotid injury (RICI). The RICI mechanisms are complex, including vessel inflammatory injury, carotid atherosclerosis, intimal proliferation, media necrosis, and peri-adventitial fibrosis. The main manifestation and adverse consequence of RICI is carotid artery stenosis (CAS), which can lead to stroke and transient ischemic attack. Currently, carotid artery injury is primarily diagnosed via color-coded duplex sonography. Early detection of traumatic changes in the carotid artery depends on measurements of carotid intima-media thickness; serum biomarker testing also shows great potential. CAS is mainly treated with carotid endarterectomy or carotid angioplasty and stent implantation. Notably, bone marrow mesenchymal stem cells are advantageous in RICI treatment and reduce carotid inflammation, oxidative stress, and delaying atherosclerosis. This review summarizes the mechanisms, examination methods, and latest treatments for RICI to provide data for its clinical prevention and treatment.
Collapse
Affiliation(s)
- Zhuangzhuang Zheng
- Department of Radiation Oncology, The First Hospital of Jilin University, Changchun, 130021, China; Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, 130021, China; NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| | - Qin Zhao
- Department of Radiation Oncology, The First Hospital of Jilin University, Changchun, 130021, China; Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, 130021, China; NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| | - Jinlong Wei
- Department of Radiation Oncology, The First Hospital of Jilin University, Changchun, 130021, China; Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, 130021, China; NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| | - Bin Wang
- Department of Radiation Oncology, The First Hospital of Jilin University, Changchun, 130021, China; Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, 130021, China; NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| | - Huanhuan Wang
- Department of Radiation Oncology, The First Hospital of Jilin University, Changchun, 130021, China; Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, 130021, China; NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| | - Lingbin Meng
- Department of Hematology and Medical Oncology, Moffitt Cancer Center, Tampa, FL, 33612, USA.
| | - Ying Xin
- Key Laboratory of Pathobiology, Ministry of Education, Jilin University, Changchun, 130021, China.
| | - Xin Jiang
- Department of Radiation Oncology, The First Hospital of Jilin University, Changchun, 130021, China; Jilin Provincial Key Laboratory of Radiation Oncology & Therapy, The First Hospital of Jilin University, Changchun, 130021, China; NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| |
Collapse
|
7
|
Torres G, Czernuszewicz TJ, Homeister JW, Caughey MC, Huang BY, Lee ER, Zamora CA, Farber MA, Marston WA, Huang DY, Nichols TC, Gallippi CM. Delineation of Human Carotid Plaque Features In Vivo by Exploiting Displacement Variance. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:481-492. [PMID: 30762544 PMCID: PMC7952026 DOI: 10.1109/tuffc.2019.2898628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
While in vivo acoustic radiation force impulse (ARFI)-induced peak displacement (PD) has been demonstrated to have high sensitivity and specificity for differentiating soft from stiff plaque components in patients with carotid plaque, the parameter exhibits poorer performance for distinguishing between plaque features with similar stiffness. To improve discrimination of carotid plaque features relative to PD, we hypothesize that signal correlation and signal-to-noise ratio (SNR) can be combined, outright or via displacement variance. Plaque feature detection by displacement variance, evaluated as the decadic logarithm of the variance of acceleration and termed "log(VoA)," was compared to that achieved by exploiting SNR, cross correlation coefficient, and ARFI-induced PD outcome metrics. Parametric images were rendered for 25 patients undergoing carotid endarterectomy, with spatially matched histology confirming plaque composition and structure. On average, across all plaques, log(VoA) was the only outcome metric with values that statistically differed between regions of lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), collagen (COL), and calcium (CAL). Further, log(VoA) achieved the highest contrast-to-noise ratio (CNR) for discriminating between LRNC and IPH, COL and CAL, and grouped soft (LRNC and IPH) and stiff (COL and CAL) plaque components. More specifically, relative to the previously demonstrated ARFI PD parameter, log(VoA) achieved 73% higher CNR between LRNC and IPH and 59% higher CNR between COL and CAL. These results suggest that log(VoA) enhances the differentiation of LRNC, IPH, COL, and CAL in human carotid plaques, in vivo, which is clinically relevant to improving stroke risk prediction and medical management.
Collapse
|
8
|
Urban M. Current and Future Clinical Applications of Elasticity Imaging Techniques. ULTRASOUND ELASTOGRAPHY FOR BIOMEDICAL APPLICATIONS AND MEDICINE 2018:471-491. [DOI: 10.1002/9781119021520.ch30] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
9
|
McGarry M, Nauleau P, Apostolakis I, Konofagou E. In vivo repeatability of the pulse wave inverse problem in human carotid arteries. J Biomech 2017; 64:136-144. [PMID: 29050824 DOI: 10.1016/j.jbiomech.2017.09.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 08/08/2017] [Accepted: 09/19/2017] [Indexed: 10/18/2022]
Abstract
Accurate arterial stiffness measurement would improve diagnosis and monitoring for many diseases. Atherosclerotic plaques and aneurysms are expected to involve focal changes in vessel wall properties; therefore, a method to image the stiffness variation would be a valuable clinical tool. The pulse wave inverse problem (PWIP) fits unknown parameters from a computational model of arterial pulse wave propagation to ultrasound-based measurements of vessel wall displacements by minimizing the difference between the model and measured displacements. The PWIP has been validated in phantoms, and this study presents the first in vivo demonstration. The common carotid arteries of five healthy volunteers were imaged five times in a single session with repositioning of the probe and subject between each scan. The 1D finite difference computational model used in the PWIP spanned from the start of the transducer to the carotid bifurcation, where a resistance outlet boundary condition was applied to approximately model the downstream reflection of the pulse wave. Unknown parameters that were estimated by the PWIP included a 10-segment linear piecewise compliance distribution and 16 discrete cosine transformation coefficients for each of the inlet boundary conditions. Input data was selected to include pulse waves resulting from the primary pulse and dicrotic notch. The recovered compliance maps indicate that the compliance increases close to the bifurcation, and the variability of the average pulse wave velocity estimated through the PWIP is on the order of 11%, which is similar to that of the conventional processing technique which tracks the wavefront arrival time (13%).
Collapse
Affiliation(s)
- Matthew McGarry
- Department of Biomedical Engineering, Columbia University, New York, NY, United States; Thayer School of Engineering, Dartmouth College, Hanover, NH, United States
| | - Pierre Nauleau
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Iason Apostolakis
- Department of Biomedical Engineering, Columbia University, New York, NY, United States
| | - Elisa Konofagou
- Department of Biomedical Engineering, Columbia University, New York, NY, United States; Department of Radiology, Columbia University, New York, NY, United States.
| |
Collapse
|
10
|
Czernuszewicz TJ, Homeister JW, Caughey MC, Wang Y, Zhu H, Huang BY, Lee ER, Zamora CA, Farber MA, Fulton JJ, Ford PF, Marston WA, Vallabhaneni R, Nichols TC, Gallippi CM. Performance of acoustic radiation force impulse ultrasound imaging for carotid plaque characterization with histologic validation. J Vasc Surg 2017; 66:1749-1757.e3. [PMID: 28711401 DOI: 10.1016/j.jvs.2017.04.043] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2017] [Accepted: 04/18/2017] [Indexed: 11/17/2022]
Abstract
OBJECTIVE Stroke is commonly caused by thromboembolic events originating from ruptured carotid plaque with vulnerable composition. This study assessed the performance of acoustic radiation force impulse (ARFI) imaging, a noninvasive ultrasound elasticity imaging method, for delineating the composition of human carotid plaque in vivo with histologic validation. METHODS Carotid ARFI images were captured before surgery in 25 patients undergoing clinically indicated carotid endarterectomy. The surgical specimens were histologically processed with sectioning matched to the ultrasound imaging plane. Three radiologists, blinded to histology, evaluated parametric images of ARFI-induced peak displacement to identify plaque features such as necrotic core (NC), intraplaque hemorrhage (IPH), collagen (COL), calcium (CAL), and fibrous cap (FC) thickness. Reader performance was measured against the histologic standard using receiver operating characteristic curve analysis, linear regression, Spearman correlation (ρ), and Bland-Altman analysis. RESULTS ARFI peak displacement was two-to-four-times larger in regions of NC and IPH relative to regions of COL or CAL. Readers detected soft plaque features (NC/IPH) with a median area under the curve of 0.887 (range, 0.867-0.924) and stiff plaque features (COL/CAL) with median area under the curve of 0.859 (range, 0.771-0.929). FC thickness measurements of two of the three readers correlated with histology (reader 1: R2 = 0.64, ρ = 0.81; reader 2: R2 = 0.89, ρ = 0.75). CONCLUSIONS This study suggests that ARFI is capable of distinguishing soft from stiff atherosclerotic plaque components and delineating FC thickness.
Collapse
Affiliation(s)
- Tomasz J Czernuszewicz
- Joint Department of Biomedical Engineering, The University of North Carolina, Chapel Hill, and North Carolina State University, Raleigh, NC
| | - Jonathon W Homeister
- Department of Pathology and Laboratory Medicine, The University of North Carolina, Chapel Hill, NC
| | - Melissa C Caughey
- Department of Medicine, The University of North Carolina, Chapel Hill, NC
| | - Yue Wang
- Department of Biostatistics, The University of North Carolina, Chapel Hill, NC
| | - Hongtu Zhu
- Department of Biostatistics, The University of North Carolina, Chapel Hill, NC
| | - Benjamin Y Huang
- Department of Radiology, The University of North Carolina, Chapel Hill, NC
| | - Ellie R Lee
- Department of Radiology, The University of North Carolina, Chapel Hill, NC
| | - Carlos A Zamora
- Department of Radiology, The University of North Carolina, Chapel Hill, NC
| | - Mark A Farber
- Department of Surgery, The University of North Carolina, Chapel Hill, NC
| | - Joseph J Fulton
- Department of Surgery, The University of North Carolina, Chapel Hill, NC
| | - Peter F Ford
- Department of Surgery, The University of North Carolina, Chapel Hill, NC
| | - William A Marston
- Department of Surgery, The University of North Carolina, Chapel Hill, NC
| | | | - Timothy C Nichols
- Department of Pathology and Laboratory Medicine, The University of North Carolina, Chapel Hill, NC; Department of Medicine, The University of North Carolina, Chapel Hill, NC
| | - Caterina M Gallippi
- Joint Department of Biomedical Engineering, The University of North Carolina, Chapel Hill, and North Carolina State University, Raleigh, NC; Department of Radiology, The University of North Carolina, Chapel Hill, NC; Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC.
| |
Collapse
|
11
|
Qu Y, Ma T, He Y, Yu M, Zhu J, Miao Y, Dai C, Patel P, Shung KK, Zhou Q, Chen Z. Miniature probe for mapping mechanical properties of vascular lesions using acoustic radiation force optical coherence elastography. Sci Rep 2017; 7:4731. [PMID: 28680156 PMCID: PMC5498569 DOI: 10.1038/s41598-017-05077-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Accepted: 05/24/2017] [Indexed: 12/15/2022] Open
Abstract
Cardiovascular diseases are the leading cause of fatalities in the United States. Atherosclerotic plaques are one of the primary complications that can lead to strokes and heart attacks if left untreated. It is essential to diagnose the disease early and distinguish vulnerable plaques from harmless ones. Many methods focus on the structural or molecular properties of plaques. Mechanical properties have been shown to change drastically when abnormalities develop in arterial tissue. We report the development of an acoustic radiation force optical coherence elastography (ARF-OCE) system that uses an integrated miniature ultrasound and optical coherence tomography (OCT) probe to map the relative elasticity of vascular tissues. We demonstrate the capability of the miniature probe to map the biomechanical properties in phantom and human cadaver carotid arteries.
Collapse
Affiliation(s)
- Yueqiao Qu
- Beckman Laser Institute, University of California, Irvine, 1002 Health Sciences Rd., Irvine, CA, 92617, USA.,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2700, USA
| | - Teng Ma
- NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, CA, 90089, USA
| | - Youmin He
- Beckman Laser Institute, University of California, Irvine, 1002 Health Sciences Rd., Irvine, CA, 92617, USA.,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2700, USA
| | - Mingyue Yu
- NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, CA, 90089, USA
| | - Jiang Zhu
- Beckman Laser Institute, University of California, Irvine, 1002 Health Sciences Rd., Irvine, CA, 92617, USA
| | - Yusi Miao
- Beckman Laser Institute, University of California, Irvine, 1002 Health Sciences Rd., Irvine, CA, 92617, USA.,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2700, USA
| | - Cuixia Dai
- Beckman Laser Institute, University of California, Irvine, 1002 Health Sciences Rd., Irvine, CA, 92617, USA.,Shanghai Institute of Technology, 100 Haiquan Road, Fengxian, Shanghai, China
| | - Pranav Patel
- Division of Cardiology, Irvine Medical Center, University of California, Orange, CA, 92868, USA
| | - K Kirk Shung
- NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, CA, 90089, USA
| | - Qifa Zhou
- NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, CA, 90089, USA.
| | - Zhongping Chen
- Beckman Laser Institute, University of California, Irvine, 1002 Health Sciences Rd., Irvine, CA, 92617, USA. .,Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, 92697-2700, USA.
| |
Collapse
|
12
|
de Korte CL, Fekkes S, Nederveen AJ, Manniesing R, Hansen HRHG. Review: Mechanical Characterization of Carotid Arteries and Atherosclerotic Plaques. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1613-1623. [PMID: 27249826 DOI: 10.1109/tuffc.2016.2572260] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Cardiovascular disease (CVD) is a leading cause of death and is in the majority of cases due to the formation of atherosclerotic plaques in arteries. Initially, thickening of the inner layer of the arterial wall occurs. Continuation of this process leads to plaque formation. The risk of a plaque to rupture and thus to induce an ischemic event is directly related to its composition. Consequently, characterization of the plaque composition and its proneness to rupture are of crucial importance for risk assessment and treatment strategies. The carotid is an excellent artery to be imaged with ultrasound because of its superficial position. In this review, ultrasound-based methods for characterizing the mechanical properties of the carotid wall and atherosclerotic plaque are discussed. Using conventional echography, the intima media thickness (IMT) can be quantified. There is a wealth of studies describing the relation between IMT and the risk for myocardial infarction and stroke. Also the carotid distensibility can be quantified with ultrasound, providing a surrogate marker for the cross-sectional mechanical properties. Although all these parameters are associated with CVD, they do not easily translate to individual patient risk. Another technique is pulse wave velocity (PWV) assessment, which measures the propagation of the pressure pulse over the arterial bed. PWV has proven to be a marker for global arterial stiffness. Recently, an ultrasound-based method to estimate the local PWV has been introduced, but the clinical effectiveness still needs to be established. Other techniques focus on characterization of plaques. With ultrasound elastography, the strain in the plaque due to the pulsatile pressure can be quantified. This technique was initially developed using intravascular catheters to image coronaries, but recently noninvasive methods were successfully developed. A high correlation between the measured strain and the risk for rupture was established. Acoustic radiation force impulse (ARFI) imaging also provides characterization of local plaque components based on mechanical properties. However, both elastography and ARFI provide an indirect measure of the elastic modulus of tissue. With shear wave imaging, the elastic modulus can be quantified, although the carotid artery is one of the most challenging tissues for this technique due to its size and geometry. Prospective studies still have to establish the predictive value of these techniques for the individual patient. Validation of ultrasound-based mechanical characterization of arteries and plaques remains challenging. Magnetic resonance imaging is often used as the "gold" standard for plaque characterization, but its limited resolution renders only global characterization of the plaque. CT provides information on the vascular tree, the degree of stenosis, and the presence of calcified plaque, while soft plaque characterization remains limited. Histology still is the gold standard, but is available only if tissue is excised. In conclusion, elastographic ultrasound techniques are well suited to characterize the different stages of vascular disease.
Collapse
|
13
|
Widman E, Maksuti E, Amador C, Urban MW, Caidahl K, Larsson M. Shear Wave Elastography Quantifies Stiffness in Ex Vivo Porcine Artery with Stiffened Arterial Region. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2423-2435. [PMID: 27425151 DOI: 10.1016/j.ultrasmedbio.2016.05.021] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 05/17/2016] [Accepted: 05/31/2016] [Indexed: 06/06/2023]
Abstract
Five small porcine aortas were used as a human carotid artery model, and their stiffness was estimated using shear wave elastography (SWE) in the arterial wall and a stiffened artery region mimicking a stiff plaque. To optimize the SWE settings, shear wave bandwidth was measured with respect to acoustic radiation force push length and number of compounded angles used for motion detection with plane wave imaging. The mean arterial wall and simulated plaque shear moduli varied from 41 ± 5 to 97 ± 10 kPa and from 86 ± 13 to 174 ± 35 kPa, respectively, over the pressure range 20-120 mmHg. The results revealed that a minimum bandwidth of approximately 1500 Hz is necessary for consistent shear modulus estimates, and a high pulse repetition frequency using no image compounding is more important than a lower pulse repetition frequency with better image quality when estimating arterial wall and plaque stiffness using SWE.
Collapse
Affiliation(s)
- Erik Widman
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden.
| | - Elira Maksuti
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - Carolina Amador
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Matthew W Urban
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA; Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota, USA
| | - Kenneth Caidahl
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| | - Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Molecular Medicine and Surgery, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
14
|
Czernuszewicz TJ, Gallippi CM. On the Feasibility of Quantifying Fibrous Cap Thickness With Acoustic Radiation Force Impulse (ARFI) Ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1262-75. [PMID: 26955026 PMCID: PMC5084842 DOI: 10.1109/tuffc.2016.2535440] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Acute cerebrovascular accidents are associated with the rupture of vulnerable atherosclerotic plaques in the carotid arteries. Fibrous cap (FC) thickness has been shown to be an important predictor of plaque rupture but has been challenging to measure accurately with clinical noninvasive imaging modalities. The goals of this investigation were first, to evaluate the feasibility of using transcutaneous acoustic radiation force impulse (ARFI) ultrasound to quantify FC thickness and second, to optimize both imaging and motion-tracking parameters to support such measurements. FCs with varying thickness (0.1-1.0 mm) were simulated using a simple-layered geometry, and their mechanical response to an impulse of radiation force was solved using finite-element method (FEM) modeling. Ultrasound tracking of FEM displacements was performed in Field II utilizing three center frequencies (6, 9, and 12 MHz) and eight motion-tracking kernel lengths ( 0.5λ-4λ). Additionally, FC thickness in two carotid plaques imaged in vivo was measured with ARFI and compared to matched histology. The results of this study demonstrate that 1) tracking pulse frequencies around 12 MHz are necessary to resolve caps around 0.2 mm; 2) large motion-tracking kernel sizes introduce bias into thickness measurements and overestimate the true cap thickness; and 3) color saturation settings on ARFI peak displacement images can impact thickness measurement accuracy substantially.
Collapse
Affiliation(s)
- Tomasz J. Czernuszewicz
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC, USA
| | - Caterina M. Gallippi
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC, USA. Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
| |
Collapse
|
15
|
Zhang YF, Xu HX, Xu JM, Liu C, Guo LH, Liu LN, Zhang J, Xu XH, Qu S, Xing M. Acoustic Radiation Force Impulse Elastography in the Diagnosis of Thyroid Nodules: Useful or Not Useful? ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2581-2593. [PMID: 26119458 DOI: 10.1016/j.ultrasmedbio.2015.05.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2014] [Revised: 05/21/2015] [Accepted: 05/22/2015] [Indexed: 06/04/2023]
Abstract
The goal of this study is to evaluate the diagnostic performance of acoustic radiation force impulse (ARFI) elastography for differentiating benign from malignant thyroid nodules. One hundred and seventy-four pathologically proven thyroid nodules (139 benign, 35 malignant) in 154 patients (mean age: 49.2 ± 12.1 y; range: 16-72 y) were included in this study. Conventional ultrasound (US) and ARFI elastography using virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ) were performed to examine the thyroid nodules. Two blinded readers with different amounts of experience independently scored the likelihood of malignancy on the basis of a five-point scale in three different image-reading sets. The diagnostic performances among different image-reading sets and between the two readers were compared. The diagnostic specificity of both readers improved significantly after reading the VTI images or both VTI and VTQ images (all p < 0.05). After review of the results of both VTI and VTQ, the numbers of correctly diagnosed nodules increased in nodules <1.0 cm for both readers and in both nodular goiter and papillary thyroid carcinoma for the junior reader (p < 0.05). The nodules with definite diagnoses (i.e., confidence levels including definite benign and definite malignant cases) increased after review of VTI and VTQ images versus conventional US for the senior reader (p < 0.05). In conclusion, adding ARFI elastography improves the specificity in diagnosing malignant thyroid nodules compared with conventional US on its own. ARFI elastography particularly facilitates the specific diagnosis for thyroid nodules smaller than 1.0 cm. ARFI elastography is also able to increase the diagnostic confidence of the readers.
Collapse
Affiliation(s)
- Yi-Feng Zhang
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China
| | - Hui-Xiong Xu
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Department of Ultrasound, Guangdong Medical College Affiliated Hospital, Zhanjiang, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China.
| | - Jun-Mei Xu
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China
| | - Chang Liu
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China
| | - Le-Hang Guo
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China
| | - Lin-Na Liu
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China
| | - Jing Zhang
- Department of Medical Ultrasound, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China; Thyroid Institute, Tongji University School of Medicine, Shanghai, China
| | - Xiao-Hong Xu
- Department of Ultrasound, Guangdong Medical College Affiliated Hospital, Zhanjiang, China
| | - Shen Qu
- Thyroid Institute, Tongji University School of Medicine, Shanghai, China; Department of Endocrinology and Metabolism, Shanghai 10th People's Hospital, Tongji University School of Medicine, Shanghai, China
| | - Mingzhao Xing
- Thyroid Institute, Tongji University School of Medicine, Shanghai, China; Department of Endocrinology, Diabetes & Metabolism, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
16
|
Steinl DC, Kaufmann BA. Ultrasound imaging for risk assessment in atherosclerosis. Int J Mol Sci 2015; 16:9749-69. [PMID: 25938969 PMCID: PMC4463615 DOI: 10.3390/ijms16059749] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2015] [Revised: 04/09/2015] [Accepted: 04/09/2015] [Indexed: 01/28/2023] Open
Abstract
Atherosclerosis and its consequences like acute myocardial infarction or stroke are highly prevalent in western countries, and the incidence of atherosclerosis is rapidly rising in developing countries. Atherosclerosis is a disease that progresses silently over several decades before it results in the aforementioned clinical consequences. Therefore, there is a clinical need for imaging methods to detect the early stages of atherosclerosis and to better risk stratify patients. In this review, we will discuss how ultrasound imaging can contribute to the detection and risk stratification of atherosclerosis by (a) detecting advanced and early plaques; (b) evaluating the biomechanical consequences of atherosclerosis in the vessel wall;
Collapse
Affiliation(s)
- David C Steinl
- Department of Biomedicine, University Hospital Basel, Hebelstrasse 20, Basel 4031, Switzerland.
| | - Beat A Kaufmann
- Division of Cardiology, University Hospital Basel, Petersgraben 4, Basel 4031, Switzerland.
| |
Collapse
|
17
|
Widman E, Maksuti E, Larsson D, Urban MW, Bjällmark A, Larsson M. Shear wave elastography plaque characterization with mechanical testing validation: a phantom study. Phys Med Biol 2015; 60:3151-74. [PMID: 25803520 DOI: 10.1088/0031-9155/60/8/3151] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
18
|
Czernuszewicz TJ, Homeister JW, Caughey MC, Farber MA, Fulton JJ, Ford PF, Marston WA, Vallabhaneni R, Nichols TC, Gallippi CM. Non-invasive in vivo characterization of human carotid plaques with acoustic radiation force impulse ultrasound: comparison with histology after endarterectomy. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:685-97. [PMID: 25619778 PMCID: PMC4331250 DOI: 10.1016/j.ultrasmedbio.2014.09.016] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 08/30/2014] [Accepted: 09/10/2014] [Indexed: 05/03/2023]
Abstract
Ischemic stroke from thromboembolic sources is linked to carotid artery atherosclerotic disease with a trend toward medical management in asymptomatic patients. Extent of disease is currently diagnosed by non-invasive imaging techniques that measure luminal stenosis, but it has been suggested that a better biomarker for determining risk of future thromboembolic events is plaque morphology and composition. Specifically, plaques that are composed of mechanically soft lipid/necrotic regions covered by thin fibrous caps are the most vulnerable to rupture. An ultrasound technique that non-invasively interrogates the mechanical properties of soft tissue, called acoustic radiation force impulse (ARFI) imaging, has been developed as a new modality for atherosclerotic plaque characterization using phantoms and atherosclerotic pigs, but the technique has yet to be validated in vivo in humans. In this preliminary study, in vivo ARFI imaging is presented in a case study format for four patients undergoing clinically indicated carotid endarterectomy and compared with histology. In two type Va plaques, characterized by lipid/necrotic cores covered by fibrous caps, mean ARFI displacements in focal regions were high relative to the surrounding plaque material, suggesting soft features were covered by stiffer layers within the plaques. In two type Vb plaques, characterized by heavy calcification, mean ARFI peak displacements were low relative to the surrounding plaque and arterial wall, suggesting stiff tissue. This pilot study illustrates the feasibility and challenges of transcutaneous ARFI for characterizing the material and structural composition of carotid atherosclerotic plaques via mechanical properties, in humans, in vivo.
Collapse
Affiliation(s)
- Tomasz J Czernuszewicz
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, North Carolina, USA
| | - Jonathon W Homeister
- Department of Pathology and Laboratory Medicine, University of North Carolina, Chapel Hill, North Carolina, USA; McAllister Heart Institute, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Melissa C Caughey
- Department of Medicine, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Mark A Farber
- Department of Surgery, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Joseph J Fulton
- Department of Surgery, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Peter F Ford
- Department of Surgery, University of North Carolina, Chapel Hill, North Carolina, USA
| | - William A Marston
- Department of Surgery, University of North Carolina, Chapel Hill, North Carolina, USA
| | | | - Timothy C Nichols
- Department of Pathology and Laboratory Medicine, University of North Carolina, Chapel Hill, North Carolina, USA; Department of Medicine, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Caterina M Gallippi
- McAllister Heart Institute, University of North Carolina, Chapel Hill, North Carolina, USA; Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, North Carolina, USA; Biomedical Research Imaging Center, University of North Carolina, Chapel Hill, North Carolina, USA.
| |
Collapse
|
19
|
Widman E, Caidahl K, Heyde B, D'hooge J, Larsson M. Ultrasound speckle tracking strain estimation of in vivo carotid artery plaque with in vitro sonomicrometry validation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:77-88. [PMID: 25308946 DOI: 10.1016/j.ultrasmedbio.2014.06.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Revised: 06/03/2014] [Accepted: 06/23/2014] [Indexed: 06/04/2023]
Abstract
Our objective was to validate a previously developed speckle tracking (ST) algorithm to assess strain in common carotid artery plaques. Radial and longitudinal strain was measured in common carotid artery gel phantoms with a plaque-mimicking inclusion using an in-house ST algorithm and sonomicrometry. Moreover, plaque strain by ST for seven patients (77 ± 6 y) with carotid atherosclerosis was compared with a quantitative visual assessment by two experienced physicians. In vitro, good correlation existed between ST and sonomicrometry peak strains, both radially (r = 0.96, p < 0.001) and longitudinally (r = 0.75, p < 0.01). In vivo, greater pulse pressure-adjusted radial and longitudinal strains were found in echolucent plaques than in echogenic plaques. This illustrates the feasibility of ultrasound ST strain estimation in plaques and the possibility of characterizing plaques using ST strain in vivo.
Collapse
Affiliation(s)
- Erik Widman
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Kenneth Caidahl
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Brecht Heyde
- Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Jan D'hooge
- Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Matilda Larsson
- Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden; Cardiovascular Imaging & Dynamics, Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| |
Collapse
|
20
|
Szczepanek-Parulska E, Woliński K, Stangierski A, Gurgul E, Ruchała M. Biochemical and ultrasonographic parameters influencing thyroid nodules elasticity. Endocrine 2014; 47:519-27. [PMID: 24535467 DOI: 10.1007/s12020-014-0197-y] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Accepted: 01/29/2014] [Indexed: 10/25/2022]
Abstract
Elastography is a method of tissue stiffness assessment. It has already been demonstrated that thyroid cancers are less elastic than benign lesions. However, little is known about other factors, which might influence the stiffness of thyroid nodules and disrupt the prediction of malignancy using this technique. The aim of this study was to conduct the first systematic assessment of factors potentially affecting the elasticity of thyroid lesions. One hundred and twenty-two patients with thyroid nodular disease admitted for thyroidectomy underwent preoperative ultrasonography and sonoelastography. The definite diagnosis of thyroid lesions was based on histological examination. What was evaluated in the study was the influence of composition, size, localization, nodularity, and selected laboratory parameters on thyroid nodule elasticity. Firstly, association between the above-mentioned factors and elasticity was assessed in benign lesions. Secondly, all nodules (benign and malignant) were divided into subgroups according to the presence or absence of particular features, which turned out to be an important disturbing factor increasing the stiffness of the lesion in the first step of analysis. There were 22 malignant and 371 benign lesions. The analysis of benign lesions revealed that the presence calcifications (p < 0.0001) significantly increased nodule stiffness. Partially, cystic nodules were significantly less elastic than solid ones (p = 0.03). There was also positive correlation between nodule size and stiffness (p < 0.0001). Lesions localized in the isthmus were significantly less elastic than nodules in other localizations. (p = 0.0001). Solitary nodules were less elastic than lesions in multinodular goiter (p = 0.006). Correlation between Tg concentration and stiffness was significant (p < 0.0001, r = 0.24). The concentration of anti-thyroid autoantibodies was associated with stiffness at the border of significance. However, there was no significant difference between benign lesions in patients with diagnosed chronic autoimmune thyroiditis and patients without the disease. The analysis of the entire group of nodules revealed that shear wave elastography is a valuable modality of thyroid nodule assessment, with sensitivity of over 95 % and specificity of about 70 %. However, the stiffness value of the lesion might be increased in the case of nodules containing calcifications, cystic component, and those of size above 20 mm. Certain clinical conditions or attributes of the lesions influence the stiffness values of thyroid nodules. Identifying these variables is the basis for a credible interpretation of the results of a sonoelastographic examination and makes it possible to estimate the risk of thyroid nodule malignancy adequately.
Collapse
Affiliation(s)
- Ewelina Szczepanek-Parulska
- Department of Endocrinology, Metabolism and Internal Medicine, Poznan University of Medical Sciences, 49 Przybyszewskiego St, 60-355, Poznan, Poland
| | | | | | | | | |
Collapse
|
21
|
Majdouline Y, Ohayon J, Keshavarz-Motamed Z, Roy Cardinal MH, Garcia D, Allard L, Lerouge S, Arsenault F, Soulez G, Cloutier G. Endovascular shear strain elastography for the detection and characterization of the severity of atherosclerotic plaques: in vitro validation and in vivo evaluation. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:890-903. [PMID: 24495438 DOI: 10.1016/j.ultrasmedbio.2013.12.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Revised: 12/04/2013] [Accepted: 12/06/2013] [Indexed: 06/03/2023]
Abstract
This work explores the potential of shear strain elastograms to identify vulnerable atherosclerotic plaques. The Lagrangian speckle model estimator (LSME) elasticity imaging method was further developed to estimate shear strain elasticity (SSE). Three polyvinyl alcohol cryogel vessel phantoms were imaged with an intravascular ultrasound (IVUS) scanner. The estimated SSE maps were validated against finite-element results. Atherosclerosis was induced in carotid arteries of eight Sinclair mini-pigs using a combination of surgical techniques, diabetes and a high-fat diet. IVUS images were acquired in vivo in 14 plaques before euthanasia and histology. All plaques were characterized by high magnitudes in SSE maps that correlated with American Heart Association atherosclerosis stage classifications (r = 0.97, p < 0.001): the worse the plaque condition the higher was the absolute value of SSE, i.e. |SSE| (e.g., mean |SSE| was 3.70 ± 0.40% in Type V plaques, whereas it was reduced to 0.11 ± 0.01% in normal walls). This study indicates the feasibility of using SSE to highlight atherosclerotic plaque vulnerability characteristics.
Collapse
Affiliation(s)
- Younes Majdouline
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
| | - Jacques Ohayon
- Laboratory TIMC-IMAG/DyCTiM, University Joseph-Fourier, CNRS UMR 5525, Grenoble, France; University of Savoie, Polytech Annecy-Chambery, Le Bourget du Lac, France
| | - Zahra Keshavarz-Motamed
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
| | - Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
| | - Damien Garcia
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada; Research Unit of Biomechanics and Imaging in Cardiology, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada; Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada
| | - Louise Allard
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada
| | - Sophie Lerouge
- Laboratory of Endovascular Biomaterials, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada; Department of Mechanical Engineering, École de technologie supérieure, Montréal, Québec, Canada
| | - Frédéric Arsenault
- Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada; Department of Radiology, University of Montreal Hospital (CHUM), Montréal, Québec, Canada
| | - Gilles Soulez
- Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada; Department of Radiology, University of Montreal Hospital (CHUM), Montréal, Québec, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montréal, Québec, Canada; Department of Radiology, Radio-Oncology and Nuclear Medicine, and Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada.
| |
Collapse
|
22
|
Razani M, Luk TW, Mariampillai A, Siegler P, Kiehl TR, Kolios MC, Yang VX. Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples. BIOMEDICAL OPTICS EXPRESS 2014; 5:895-906. [PMID: 24688822 PMCID: PMC3959849 DOI: 10.1364/boe.5.000895] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Revised: 01/16/2014] [Accepted: 02/19/2014] [Indexed: 05/04/2023]
Abstract
In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) in an inhomogeneous phantom and carotid artery samples based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 μs duration, applying acoustic radiation force (ARF) to inhomogeneous phantoms and carotid artery samples, synchronized with a swept-source OCT (SS-OCT) imaging system. The phantoms were composed of gelatin and titanium dioxide whereas the carotid artery samples were embedded in gel. Differential OCT phase maps, measured with and without the ARF, detected the microscopic displacement generated by shear wave propagation in these phantoms and samples of different stiffness. We present the technique for calculating tissue mechanical properties by propagating shear waves in inhomogeneous tissue equivalent phantoms and carotid artery samples using the ARF of an ultrasound transducer, and measuring the shear wave speed and its associated properties in the different layers with OCT phase maps. This method lays the foundation for future in-vitro and in-vivo studies of mechanical property measurements of biological tissues such as vascular tissues, where normal and pathological structures may exhibit significant contrast in the shear modulus.
Collapse
Affiliation(s)
- Marjan Razani
- Department of Physics, Ryerson University, Toronto, Canada
| | - Timothy W.H. Luk
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
| | - Adrian Mariampillai
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
| | - Peter Siegler
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
| | - Tim-Rasmus Kiehl
- Department of Pathology, University Health Network, Toronto, Ontario Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Ontario, Canada
| | | | - Victor X.D. Yang
- Department of Physics, Ryerson University, Toronto, Canada
- Department of Electrical and Computer Engineering, Ryerson University, Toronto, Canada
- Division of Neurosurgery, University of Toronto, Toronto, Canada
| |
Collapse
|
23
|
Teng Z, Sadat U, Brown AJ, Gillard JH. Plaque hemorrhage in carotid artery disease: pathogenesis, clinical and biomechanical considerations. J Biomech 2014; 47:847-58. [PMID: 24485514 PMCID: PMC3994507 DOI: 10.1016/j.jbiomech.2014.01.013] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2014] [Indexed: 12/21/2022]
Abstract
Stroke remains the most prevalent disabling illness today, with internal carotid artery luminal stenosis due to atheroma formation responsible for the majority of ischemic cerebrovascular events. Severity of luminal stenosis continues to dictate both patient risk stratification and the likelihood of surgical intervention. But there is growing evidence to suggest that plaque morphology may help improve pre-existing risk stratification criteria. Plaque components such a fibrous tissue, lipid rich necrotic core and calcium have been well investigated but plaque hemorrhage (PH) has been somewhat overlooked. In this review we discuss the pathogenesis of PH, its role in dictating plaque vulnerability, PH imaging techniques, marterial properties of atherosclerotic tissues, in particular, those obtained based on in vivo measurements and effect of PH in modulating local biomechanics.
Collapse
Affiliation(s)
- Zhongzhao Teng
- University Department of Radiology, University of Cambridge, UK; Department of Engineering, University of Cambridge, UK.
| | - Umar Sadat
- Department of Surgery, Cambridge University Hospitals NHS Foundation Trust, UK
| | - Adam J Brown
- Department of Cardiovascular Medicine, University of Cambridge, UK
| | | |
Collapse
|
24
|
Kafi H, Salamzadeh J, Beladimoghadam N, Sistanizad M, Kouchek M. Study of the neuroprotective effects of memantine in patients with mild to moderate ischemic stroke. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH : IJPR 2014; 13:591-8. [PMID: 25237355 PMCID: PMC4157035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Ischemic stroke is amongst the top four causes of mortality and the leading cause of disability in the world. The aim of this study was to evaluate the efficacy of a high dose memantine on neurological function of patients with ischemic stroke. In a randomized, 2 armed, open-label study, patients with mild to moderate cerebral thromboembolic event (CTEE) who admitted to Imam Hossein Hospital, Tehran, Iran, during preceding 24 hours, entered the study. Patients allocated in two study groups of memantine (as add-on therapy) and control. All patients were managed based on the American Heart Association and American Stroke Association (AHA/ASA) guidelines. Patients in memantine group received conventional treatment plus memantine 20 mg TID. The National Institute of Health Stroke Scale (NIHSS) was determined and recorded daily. The primary objective was comparison of the changes in NIHSS in the study groups at day 1 and day 5 of intervention. Significance level of p<0.05 was considered for statistical analysis. Patients were randomly allocated in control (15 women and 14 men, age 70.78 ± 10.92 years) and memantine (16 women and 8 men, age 73.33 ± 9.35 years) groups. There were no significant differences in age and sex distribution of two study groups as well as in comorbidities and concurrent drugs. NIHSS changes were significantly different between control (1.24 ± 0.96) and memantine group (2.96 ± 0.1), (p < 0.0001). Our results reveal that memantine added to standard treatment of CTEE could result in a remarkable decrease in the NIHSS confirming improvement of the neurological function of the patients.
Collapse
Affiliation(s)
- Hamidreza Kafi
- Department of Clinical Pharmacy, Faculty of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Jamshid Salamzadeh
- Department of Clinical Pharmacy, Faculty of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Nahid Beladimoghadam
- Department of Neurology, Imam Hossein Medical and Educational Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Mohammad Sistanizad
- Department of Clinical Pharmacy, Faculty of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran. ,Imam Hossein Medical and Educational Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Mehran Kouchek
- Imam Hossein Medical and Educational Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Corresponding author: E-mail:
| |
Collapse
|
25
|
Naim C, Douziech M, Therasse E, Robillard P, Giroux MF, Arsenault F, Cloutier G, Soulez G. Vulnerable atherosclerotic carotid plaque evaluation by ultrasound, computed tomography angiography, and magnetic resonance imaging: an overview. Can Assoc Radiol J 2013; 65:275-86. [PMID: 24360724 DOI: 10.1016/j.carj.2013.05.003] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Accepted: 05/31/2013] [Indexed: 01/23/2023] Open
Abstract
Ischemic syndromes associated with carotid atherosclerotic disease are often related to plaque rupture. The benefit of endarterectomy for high-grade carotid stenosis in symptomatic patients has been established. However, in asymptomatic patients, the benefit of endarterectomy remains equivocal. Current research seeks to risk stratify asymptomatic patients by characterizing vulnerable, rupture-prone atherosclerotic plaques. Plaque composition, biology, and biomechanics are studied by noninvasive imaging techniques such as magnetic resonance imaging, computed tomography, ultrasound, and ultrasound elastography. These techniques are at a developmental stage and have yet to be used in clinical practice. This review will describe noninvasive techniques in ultrasound, magnetic resonance imaging, and computed tomography imaging modalities used to characterize atherosclerotic plaque, and will discuss their potential clinical applications, benefits, and drawbacks.
Collapse
Affiliation(s)
- Cyrille Naim
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada; Research Centre of the Centre Hospitalier de l'Université de Montréal and Université de Montréal, Montreal, Québec, Canada
| | - Maxime Douziech
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada
| | - Eric Therasse
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada
| | - Pierre Robillard
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada
| | - Marie-France Giroux
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada
| | - Frederic Arsenault
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada
| | - Guy Cloutier
- Research Centre of the Centre Hospitalier de l'Université de Montréal and Université de Montréal, Montreal, Québec, Canada; Research Centre of the Centre Hospitalier de l'Université de Montréal and Université de Montréal, Montreal, Québec, Canada
| | - Gilles Soulez
- Département de Radiologie, Radio-Oncologie et Médecine Nucléaire, Université de Montréal, Montreal, Québec, Canada; Research Centre of the Centre Hospitalier de l'Université de Montréal and Université de Montréal, Montreal, Québec, Canada.
| |
Collapse
|
26
|
Bouvier A, Deleaval F, Doyley MM, Yazdani SK, Finet G, Le Floc'h S, Cloutier G, Pettigrew RI, Ohayon J. A direct vulnerable atherosclerotic plaque elasticity reconstruction method based on an original material-finite element formulation: theoretical framework. Phys Med Biol 2013; 58:8457-76. [PMID: 24240392 DOI: 10.1088/0031-9155/58/23/8457] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The peak cap stress (PCS) amplitude is recognized as a biomechanical predictor of vulnerable plaque (VP) rupture. However, quantifying PCS in vivo remains a challenge since the stress depends on the plaque mechanical properties. In response, an iterative material finite element (FE) elasticity reconstruction method using strain measurements has been implemented for the solution of these inverse problems. Although this approach could resolve the mechanical characterization of VPs, it suffers from major limitations since (i) it is not adapted to characterize VPs exhibiting high material discontinuities between inclusions, and (ii) does not permit real time elasticity reconstruction for clinical use. The present theoretical study was therefore designed to develop a direct material-FE algorithm for elasticity reconstruction problems which accounts for material heterogeneities. We originally modified and adapted the extended FE method (Xfem), used mainly in crack analysis, to model material heterogeneities. This new algorithm was successfully applied to six coronary lesions of patients imaged in vivo with intravascular ultrasound. The results demonstrated that the mean relative absolute errors of the reconstructed Young's moduli obtained for the arterial wall, fibrosis, necrotic core, and calcified regions of the VPs decreased from 95.3 ± 15.56%, 98.85 ± 72.42%, 103.29 ± 111.86% and 95.3 ± 10.49%, respectively, to values smaller than 2.6 × 10(-8) ± 5.7 × 10(-8)% (i.e. close to the exact solutions) when including modified-Xfem method into our direct elasticity reconstruction method.
Collapse
Affiliation(s)
- Adeline Bouvier
- Laboratory TIMC-IMAG/DyCTiM, UJF, CNRS UMR 5525, In3S, Grenoble, France
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Selzo MR, Gallippi CM. Viscoelastic response (VisR) imaging for assessment of viscoelasticity in Voigt materials. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:2488-500. [PMID: 24297015 PMCID: PMC4164206 DOI: 10.1109/tuffc.2013.2848] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Viscoelastic response (VisR) imaging is presented as a new acoustic radiation force (ARF)-based elastographic imaging method. Exploiting the Voigt model, VisR imaging estimates displacement in only the ARF region of excitation from one or two successive ARF impulses to estimate τσ, the relaxation time for constant stress. Double-push VisR τσ estimates were not statistically significantly different (p < 0.02) from those of shearwave dispersion ultrasound vibrometry (SDUV) or monitored steady-state excitation recovery (MSSER) ultrasound in six homogeneous viscoelastic tissue mimicking phantoms with elastic moduli ranging from 3.92 to 15.34 kPa and coefficients of viscosity ranging from 0.87 to 14.06 Pa·s. In two-dimensional imaging, double-push VisR τσ images discriminated a viscous spherical inclusion in a structured phantom with higher CNR over a larger axial range than single-push VisR or conventional acoustic radiation force impulse (ARFI) ultrasound. Finally, 2-D in vivo double-push VisR images in normal canine semitendinosus muscle were compared with spatially matched histochemistry to corroborate lower double-push VisR τσ values in highly collagenated connective tissue than in muscle, suggesting double-push VisR's in vivo relevance to diagnostic imaging, particularly in muscle. The key advantages and disadvantages to VisR, including lack of compensation for inertial terms, are discussed.
Collapse
|
28
|
Behler RH, Czernuszewicz TJ, Wu CD, Nichols TC, Zhu H, Homeister JW, Merricks EP, Gallippi CM. Acoustic radiation force beam sequence performance for detection and material characterization of atherosclerotic plaques: preclinical, ex vivo results. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:2471-87. [PMID: 24297014 PMCID: PMC4097991 DOI: 10.1109/tuffc.2013.2847] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This work presents preclinical data demonstrating performance of acoustic radiation force (ARF)-based elasticity imaging with five different beam sequences for atherosclerotic plaque detection and material characterization. Twelve trained, blinded readers evaluated parametric images taken ex vivo under simulated in vivo conditions of 22 porcine femoral arterial segments. Receiver operating characteristic (ROC) curve analysis was carried out to quantify reader performance using spatially-matched immunohistochemistry for validation. The beam sequences employed had high sensitivity (sens) and specificity (spec) for detecting Type III+ plaques (sens: 85%, spec: 79%), lipid pools (sens: 80%, spec: 86%), fibrous caps (sens: 86%, spec: 82%), calcium (sens: 96%, spec: 85%), collagen (sens: 78%, spec: 77%), and disrupted internal elastic lamina (sens: 92%, spec: 75%). 1:1 single-receive tracking yielded the highest median areas under the ROC curve (AUC), but was not statistically significantly higher than 4:1 parallel-receive tracking. Excitation focal configuration did not result in statistically different AUCs. Overall, these results suggest ARF-based imaging is relevant to detecting and characterizing plaques and support its use for diagnosing and monitoring atherosclerosis.
Collapse
|
29
|
Qi W, Li R, Ma T, Li J, Kirk Shung K, Zhou Q, Chen Z. Resonant acoustic radiation force optical coherence elastography. APPLIED PHYSICS LETTERS 2013; 103:103704. [PMID: 24086090 PMCID: PMC3779257 DOI: 10.1063/1.4820252] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2013] [Accepted: 08/21/2013] [Indexed: 05/18/2023]
Abstract
We report on a resonant acoustic radiation force optical coherence elastography (ARF-OCE) technique that uses mechanical resonant frequency to characterize and identify tissues of different types. The linear dependency of the resonant frequency on the square root of Young's modulus was validated on silicone phantoms. Both the frequency response spectrum and the 3D imaging results from the agar phantoms with hard inclusions confirmed the feasibility of deploying the resonant frequency as a mechanical contrast for tissue imaging. Furthermore, the results of resonant ARF-OCE imaging of a post-mortem human coronary artery with atherosclerosis demonstrate the potential of the resonant ARF-OCE as a non-invasive method for imaging and characterizing vulnerable plaques.
Collapse
Affiliation(s)
- Wenjuan Qi
- Beckman Laser Institute, University of California Irvine, 1002 Health Sciences Road East, Irvine, California 92612, USA ; Department of Chemical Engineering and Materials Science, University of California Irvine, Irvine, California 92697, USA
| | | | | | | | | | | | | |
Collapse
|
30
|
Su Y, DU L, Wu Y, Zhang J, Zhang X, Jia X, Cai Y, Li Y, Zhao J, Liu Q. Evaluation of cervical cancer detection with acoustic radiation force impulse ultrasound imaging. Exp Ther Med 2013; 5:1715-1719. [PMID: 23837060 PMCID: PMC3702708 DOI: 10.3892/etm.2013.1057] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2012] [Accepted: 03/08/2013] [Indexed: 12/15/2022] Open
Abstract
The aim of this study was to evaluate the application of acoustic radiation force impulse (ARFI) ultrasound imaging and its potential value in the characterization of cervical cancer. ARFI ultrasound imaging of the uterine cervix was performed in 58 patients with cervical cancer prior to surgery. The diagnosis of cervical cancer was confirmed by pathological results in each case. eSie Touch elastography imaging (EI), Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA, USA) were used to qualitatively and quantitatively analyze the elasticity and hardness of lesions. For statistical analysis, the non-parametric Mann-Whitney U test and the Student’s u test were used to compare the elastic parameters and the results. EI showed that, compared with the surrounding cervical tissue, 72.41% (42 of 58) of the malignant lesions showed 4th or 5th grade images and 27.59% (16 of 58) had 3rd grade images. The EI images showed a significant difference between the malignant lesions and the surrounding normal tissues (P<0.001). VTI showed that compared with the surrounding cervical tissue, 84.48% (49 of 58) of the malignant lesions were stiffer than the surrounding tissues and 15.52% (9 of 58) had black and white honeycomb-like images. The VTI images showed a significant difference between the malignant lesions and normal cervical tissues (P<0.001). The surrounding normal tissues had lower VTQ values, with a mean of 2.11±1.19 m/sec, while the VTQ values in malignant lesions were higher than the surrounding normal tissues (3.41±1.59 m/sec, P<0.001). ARFI ultrasound imaging of the uterine cervix may be an objective method for the assessment of soft tissues. It has high sensitivity and specificity in the evaluation of cervical cancer and therefore has good diagnostic value in clinical applications.
Collapse
Affiliation(s)
- Yijin Su
- Departments of Ultrasound, Shanghai First People's Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200080, P.R. China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Naim C, Cloutier G, Mercure E, Destrempes F, Qin Z, El-Abyad W, Lanthier S, Giroux MF, Soulez G. Characterisation of carotid plaques with ultrasound elastography: feasibility and correlation with high-resolution magnetic resonance imaging. Eur Radiol 2013; 23:2030-41. [PMID: 23417249 DOI: 10.1007/s00330-013-2772-7] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2012] [Revised: 11/19/2012] [Accepted: 12/20/2012] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To evaluate the ability of ultrasound non-invasive vascular elastography (NIVE) strain analysis to characterise carotid plaque composition and vulnerability as determined by high-resolution magnetic resonance imaging (MRI). METHODS Thirty-one subjects with 50 % or greater carotid stenosis underwent NIVE and high-resolution MRI of internal carotid arteries. Time-varying strain images (elastograms) of segmented plaques were generated from ultrasonic raw radiofrequency sequences. On MRI, corresponding plaques and components were segmented and quantified. Associations between strain parameters, plaque composition and symptomatology were estimated with curve-fitting regressions and Mann-Whitney tests. RESULTS Mean stenosis and age were 72.7 % and 69.3 years, respectively. Of 31 plaques, 9 were symptomatic, 17 contained lipid and 7 were vulnerable on MRI. Strains were significantly lower in plaques containing a lipid core compared with those without lipid, with 77-100 % sensitivity and 57-79 % specificity (P < 0.032). A statistically significant quadratic fit was found between strain and lipid content (P < 0.03). Strains did not discriminate symptomatic patients or vulnerable plaques. CONCLUSIONS Ultrasound NIVE is feasible in patients with significant carotid stenosis and can detect the presence of a lipid core with high sensitivity and moderate specificity. Studies of plaque progression with NIVE are required to identify vulnerable plaques. KEY POINTS • Non-invasive vascular elastography (NIVE) provides additional information in vascular ultrasound • Ultrasound NIVE is feasible in patients with significant carotid stenosis • Ultrasound NIVE detects a lipid core with high sensitivity and moderate specificity • Studies on plaque progression with NIVE are required to identify vulnerable plaques.
Collapse
Affiliation(s)
- Cyrille Naim
- Department of Radiology, University of Montreal Hospital Center (CHUM), Montréal, Québec, Canada.
| | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Abstract
We review the principle and some recent applications of Doppler optical coherence tomography (OCT). The advances of the phase-resolved Doppler OCT method are described. Functional OCT algorithms which are based on an extension of the phase-resolved scheme are also introduced. Recent applications of Doppler OCT for quantification of flow, imaging of microvasculature and vocal fold vibration, and optical coherence elastography are briefly discussed.
Collapse
Affiliation(s)
- Gangjun Liu
- Beckman Laser Institute, University of California, Irvine, USA
- Department of Biomedical Engineering, University of California, Irvine, USA
| | - Zhongping Chen
- Beckman Laser Institute, University of California, Irvine, USA
- Department of Biomedical Engineering, University of California, Irvine, USA
| |
Collapse
|
33
|
McCormick M, Varghese T, Wang X, Mitchell C, Kliewer MA, Dempsey RJ. Methods for robust in vivo strain estimation in the carotid artery. Phys Med Biol 2012; 57:7329-53. [PMID: 23079725 DOI: 10.1088/0031-9155/57/22/7329] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A hierarchical block-matching motion tracking algorithm for strain imaging is presented. Displacements are estimated with improved robustness and precision by utilizing a Bayesian regularization algorithm and an unbiased subsample interpolation technique. A modified least-squares strain estimator is proposed to estimate strain images from a noisy displacement input while addressing the motion discontinuity at the wall-lumen boundary. Methods to track deformation over the cardiac cycle incorporate a dynamic frame skip criterion to process data frames with sufficient deformation to produce high signal-to-noise displacement and strain images. Algorithms to accumulate displacement and/or strain on particles in a region of interest over the cardiac cycle are described. New methods to visualize and characterize the deformation measured with the full 2D strain tensor are presented. Initial results from patients imaged prior to carotid endarterectomy suggest that strain imaging detects conditions that are traditionally considered high risk including soft plaque composition, unstable morphology, abnormal hemodynamics and shear of plaque against tethering tissue can be exacerbated by neoangiogenesis. For example, a maximum absolute principal strain exceeding 0.2 is observed near calcified regions adjacent to turbulent flow, protrusion of the plaque into the arterial lumen and regions of low echogenicity associated with soft plaques. Non-invasive carotid strain imaging is therefore a potentially useful tool for detecting unstable carotid plaque.
Collapse
Affiliation(s)
- M McCormick
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA
| | | | | | | | | | | |
Collapse
|