1
|
Song Z, Li T, Zuo L, Song Y, Wei R, Dai J. A grayscale compression method to segment bone structures for 2D-3D registration of setup images in non-coplanar radiotherapy. Biomed Phys Eng Express 2024; 10:035014. [PMID: 38442730 DOI: 10.1088/2057-1976/ad3050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 03/05/2024] [Indexed: 03/07/2024]
Abstract
Purpose. To evaluate the performance of an automated 2D-3D bone registration algorithm incorporating a grayscale compression method for quantifying patient position errors in non-coplanar radiotherapy.Methods. An automated 2D-3D registration incorporating a grayscale compression method to segment bone structures was proposed. Portal images containing only bone structures (Portalbone) and digitally reconstructed radiographs containing only bone structures (DRRbone) were used for registration. First, the portal image was filtered by a high-pass finite impulse response (FIR) filter. Then the grayscale range of the filtered portal image was compressed. Thresholds were determined based on the difference in gray values of bone structures in the filtered and compressed portal image to obtainPortalbone.Another threshold was applied to generateDRRbonewhen the CT image uses the ray-casting algorithm to generate DRR images. The compression performance was assessed by registering theDRRbonewith thePortalboneobtained by compressing the portal image into various grayscale ranges. The proposed registration method was quantitatively and visually validated using (1) a CT image of an anthropomorphic head phantom and its portal images obtained in different poses and (2) CT images and pre-treatment portal images of 20 patients treated with non-coplanar radiotherapy.Results. Mean absolute registration errors for the best compression grayscale range test were 0.642 mm, 0.574 mm, and 0.643 mm, with calculation times of 50.6 min, 42.2 min, and 49.6 min for grayscale ranges of 0-127, 0-63 and 0-31, respectively. For the accuracy validation (1), the mean absolute registration errors for couch angles 0°, 45°, 90°, 270°, and 315° were 0.694 mm, 0.839 mm, 0.726 mm, 0.833 mm, and 0.873 mm, respectively. Among the six transformation parameters, the translation error in the vertical direction contributed the most to the registration errors. Visual inspection of the patient registration results revealed success in every instance.Conclusions. The implemented grayscale compression method successfully enhances and segments bone structures in portal images, allowing for accurate determination of patient setup errors in non-coplanar radiotherapy.
Collapse
Affiliation(s)
- Zhiyue Song
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Tantan Li
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Lijing Zuo
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Yongli Song
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Ran Wei
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Jianrong Dai
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| |
Collapse
|
2
|
Becksfort J, Uh J, Saunders A, Byrd JA, Worrall HM, Marker M, Melendez-Suchi C, Li Y, Chang J, Raghavan K, Merchant TE, Hua CH. Setup Uncertainty of Pediatric Brain Tumor Patients Receiving Proton Therapy: A Prospective Study. Cancers (Basel) 2023; 15:5486. [PMID: 38001746 PMCID: PMC10670653 DOI: 10.3390/cancers15225486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 11/11/2023] [Accepted: 11/13/2023] [Indexed: 11/26/2023] Open
Abstract
This study quantifies setup uncertainty in brain tumor patients who received image-guided proton therapy. Patients analyzed include 165 children, adolescents, and young adults (median age at radiotherapy: 9 years (range: 10 months to 24 years); 80 anesthetized and 85 awake) enrolled in a single-institution prospective study from 2020 to 2023. Cone-beam computed tomography (CBCT) was performed daily to calculate and correct manual setup errors, once per course after setup correction to measure residual errors, and weekly after treatments to assess intrafractional motion. Orthogonal radiographs were acquired consecutively with CBCT for paired comparisons of 40 patients. Translational and rotational errors were converted from 6 degrees of freedom to a scalar by a statistical approach that considers the distance from the target to the isocenter. The 95th percentile of setup uncertainty was reduced by daily CBCT from 10 mm (manual positioning) to 1-1.5 mm (after correction) and increased to 2 mm by the end of fractional treatment. A larger variation existed between the roll corrections reported by radiographs vs. CBCT than for pitch and yaw, while there was no statistically significant difference in translational variation. A quantile mixed regression model showed that the 95th percentile of intrafractional motion was 0.40 mm lower for anesthetized patients (p=0.0016). Considering additional uncertainty in radiation-imaging isocentricity, the commonly used total plan robustness of 3 mm against positional uncertainty would be appropriate for our study cohort.
Collapse
Affiliation(s)
- Jared Becksfort
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Jinsoo Uh
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Andrew Saunders
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Julia A. Byrd
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Hannah M. Worrall
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Matt Marker
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Christian Melendez-Suchi
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Yimei Li
- Department of Biostatistics, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA
| | - Jenghwa Chang
- Department of Radiation Medicine, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY 11549, USA
| | - Kavitha Raghavan
- Department of Pediatric Medicine, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA;
| | - Thomas E. Merchant
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| | - Chia-ho Hua
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA; (J.U.); (J.A.B.); (H.M.W.); (T.E.M.); (C.-h.H.)
| |
Collapse
|
3
|
Bolten JH, Dunst J, Siebert FA. Geometric accuracy in patient positioning for stereotactic radiotherapy of intracranial tumors. Phys Imaging Radiat Oncol 2023; 27:100461. [PMID: 37720460 PMCID: PMC10500024 DOI: 10.1016/j.phro.2023.100461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 06/20/2023] [Accepted: 06/20/2023] [Indexed: 09/19/2023] Open
Abstract
Background/Purpose This study determines and compares the geometric setup errors between stereoscopic x-ray and kilo-voltage cone beam CT (CBCT) in phantom tests on a linear accelerator (linac) for image-guided (IG) stereotactic radiotherapy of intracranial tumors. Additionally, dose-volume metrics in the target volumes of the setup errors of CBCT were evaluated. Materials/Methods A Winston-Lutz- and an anthropomorphic phantom were used. The mean deviation and root mean square error (RMSE) of CBCT and stereoscopic x-ray were compared. Dose-volume metrics of the planning target volume (PTV) and gross target volume (GTV) for CBCT were calculated. Results The RMSEs in the tests with the Winston-Lutz-Phantom were 0.3 mm, 1.1 mm and 0.3 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray in the translational dimensions (right-left, anterior-posterior and superior-inferior). The RMSEs in the tests with the anthropomorphic phantom were 0.3 mm, 0.2 mm and 0.1 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray. The effects on dose-volume metrics of the setup errors of CBCT on the GTV were within 1 % for all considered dose values. The effects on the PTV were within 5 % for all considered dose values. Conclusion Both IG systems provide high accuracy patient positioning within a submillimeter range. The phantom tests exposed a slightly higher accuracy of stereoscopic x-ray than CBCT. The comparison with other studies with a similar purpose emphasizes the importance of individual IG installation quality assurance.
Collapse
Affiliation(s)
- Jan-Hendrik Bolten
- Clinic of Radiotherapy (Radiooncology), University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Jürgen Dunst
- Clinic of Radiotherapy (Radiooncology), University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Frank-André Siebert
- Clinic of Radiotherapy (Radiooncology), University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
4
|
Iramina H, Nakamura M, Nakamura K, Fujimoto T, Mizowaki T. Quantification of six-degree-of-freedom motion during beam delivery in spine stereotactic body radiotherapy using intra-irradiation cone-beam computed tomography imaging technique. Phys Med 2023; 110:102605. [PMID: 37167776 DOI: 10.1016/j.ejmp.2023.102605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 04/22/2023] [Accepted: 05/04/2023] [Indexed: 05/13/2023] Open
Abstract
PURPOSE Quantifying intra-fractional six-degree-of-freedom (6DoF) residual errors or motion from approved patient setups is necessary for accurate beam delivery in spine stereotactic body radiotherapy. However, previously reported errors were not acquired during beam delivery. Therefore, we aimed to quantify the 6DoF residual errors and motions during arc beam delivery using a concurrent cone-beam computed tomography (CBCT) imaging technique, intra-irradiation CBCT. METHODS Consecutive 15 patients, 19 plans for various treatment sites, and 199 CBCT images were analyzed. Pre-irradiation CBCT was performed to verify shifts from the initial patient setup using the ExacTrac system. During beam delivery by two or three co-planar full-arc rotations, CBCT imaging was performed concurrently. Subsequently, an intra-irradiation CBCT image was reconstructed. Pre- and intra-irradiation CBCT images were rigidly registered to a planning CT image based on the bone to quantify 6DoF residual errors. RESULTS 6DoF residual errors quantified using pre- and intra-irradiation CBCTs were within 2.0 mm/2.0°, except for one measurement. The mean elapsed time (mean ± standard deviation [min:sec]) after pre-irradiation CBCT to the end of the last arc beam delivery was 6:08 ± 1:25 and 7:54 ± 2:14 for the 2- and 3-arc plans, respectively. Root mean squares of residual errors for several directions showed significant differences; however, they were within 1.0 mm/1.0°. Time-dependent analysis revealed that the residual errors tended to increase with elapsed time. CONCLUSION The errors represent the optimal intra-fractional error compared with those acquired using the pre-, inter-beam, and post-6DoF image guidance and can be acquired within a standard treatment timeslot.
Collapse
Affiliation(s)
- Hiraku Iramina
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Mitsuhiro Nakamura
- Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Kiyonao Nakamura
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Takahiro Fujimoto
- Division of Clinical Radiology Service, Kyoto University Hospital, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
| |
Collapse
|
5
|
Hirotaki K, Moriya S, Akita T, Yokoyama K, Sakae T. Image preprocessing to improve the accuracy and robustness of mutual-information-based automatic image registration in proton therapy. Phys Med 2022; 101:95-103. [PMID: 35987025 DOI: 10.1016/j.ejmp.2022.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Revised: 07/21/2022] [Accepted: 08/03/2022] [Indexed: 10/15/2022] Open
Abstract
PURPOSE We propose a method that potentially improves the outcome of mutual-information-based automatic image registration by using the contrast enhancement filter (CEF). METHODS Seventy-six pairs of two-dimensional X-ray images and digitally reconstructed radiographs for 20 head and neck and nine lung cancer patients were analyzed retrospectively. Automatic image registration was performed using the mutual-information-based algorithm in VeriSuite®. Images were preprocessed using the CEF in VeriSuite®. The correction vector for translation and rotation error was calculated and manual image registration was compared with automatic image registration, with and without CEF. In addition, the normalized mutual information (NMI) distribution between two-dimensional images was compared, with and without CEF. RESULTS In the correction vector comparison between manual and automatic image registration, the average differences in translation error were < 1 mm in most cases in the head and neck region. The average differences in rotation error were 0.71 and 0.16 degrees without and with CEF, respectively, in the head and neck region; they were 2.67 and 1.64 degrees, respectively, in the chest region. When used with oblique projection, the average rotation error was 0.39 degrees with CEF. CEF improved the NMI by 17.9 % in head and neck images and 18.2 % in chest images. CONCLUSIONS CEF preprocessing improved the NMI and registration accuracy of mutual-information-based automatic image registration on the medical images. The proposed method achieved accuracy equivalent to that achieved by experienced therapists and it will significantly contribute to the standardization of image registration quality.
Collapse
Affiliation(s)
- Kouta Hirotaki
- Doctoral Program in Medical Sciences, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 3058577, Japan; Department of Radiological Technology, National Cancer Center Hospital East, Chiba 2778577, Japan
| | - Shunsuke Moriya
- Faculty of Medicine, University of Tsukuba, Ibaraki 3058575, Japan.
| | - Tsunemichi Akita
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba 2778577, Japan
| | - Kazutoshi Yokoyama
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba 2778577, Japan
| | - Takeji Sakae
- Faculty of Medicine, University of Tsukuba, Ibaraki 3058575, Japan
| |
Collapse
|
6
|
Low dose cone beam CT for paediatric image-guided radiotherapy: Image quality and practical recommendations. Radiother Oncol 2021; 163:68-75. [PMID: 34343544 DOI: 10.1016/j.radonc.2021.07.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 07/22/2021] [Accepted: 07/25/2021] [Indexed: 12/25/2022]
Abstract
PURPOSE Cone beam CT (CBCT) is used in paediatric image-guided radiotherapy (IGRT) for patient setup and internal anatomy assessment. Adult CBCT protocols lead to excessive doses in children, increasing the risk of radiation-induced malignancies. Reducing imaging dose increases quantum noise, degrading image quality. Patient CBCTs also include 'anatomical noise' (e.g. motion artefacts), further degrading quality. We determine noise contributions in paediatric CBCT, recommending practical imaging protocols and thresholds above which increasing dose yields no improvement in image quality. METHODS AND MATERIALS Sixty CBCTs including the thorax or abdomen/pelvis from 7 paediatric patients (aged 6-13 years) were acquired at a range of doses and used to simulate lower dose scans, totalling 192 scans (0.5-12.8 mGy). Noise measured in corresponding regions of each patient and a 10-year-old phantom were compared, modelling total (including anatomical) noise, and quantum noise contributions as a function of dose. Contrast-to-noise ratio (CNR) was measured between fat/muscle. Soft tissue registration was performed on the kidneys, comparing accuracy to the highest dose scans. RESULTS Quantum noise contributed <20% to total noise in all cases, suggesting anatomical noise is the largest determinant of image quality in the abdominal/pelvic region. CNR exceeded 3 in over 90% of cases ≥ 1 mGy, and 57% of cases at 0.5 mGy. Soft tissue registration was accurate for doses > 1 mGy. CONCLUSION Anatomical noise dominates quantum noise in paediatric CBCT. Appropriate soft tissue contrast and registration accuracy can be achieved for doses as low as 1 mGy. Increasing dose above 1 mGy holds no benefit in improving image quality or registration accuracy due to the presence of anatomical noise.
Collapse
|
7
|
Yoon S, Yoon CH, Lee D. Topological recovery for non-rigid 2D/3D registration of coronary artery models. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 200:105922. [PMID: 33440300 DOI: 10.1016/j.cmpb.2020.105922] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 12/23/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE Intra-operative X-ray angiography, the current standard method for visualizing and diagnosing cardiovascular disease, is limited in its ability to provide essential 3D information. These limitations are disadvantages in treating patients. For example, it is a cause of lowering the success rate of interventional procedures. Here, we propose a novel 2D-3D non-rigid registration method to understand vascular geometry during percutaneous coronary intervention. METHODS The proposed method uses the local bijection pair distance as a cost function to minimize the effect of inconsistencies from center-line extraction. Moreover, novel cage-based 3D deformation and multi-threaded particle swarm optimization are utilized to implement real-time registration. We evaluated the proposed method for 154 examinations from 10 anonymous patients by coverage percentage, comparing the average distance of the 2D extracted center-line with that of the registered 3D center-line. RESULTS The proposed 2D-3D non-rigid registration method achieved an average distance of 1.98 mm with a 0.54 s computation time. Additionally, in aiming to reduce the uncertainty of XA images, we used the proposed method to retrospectively visualize the connections between 2D vascular segments and the distal part of occlusions. CONCLUSIONS Ultimately, the proposed 2D/3D non-rigid registration method can successfully register the 3D center-line of coronary arteries with corresponding 2D XA images, and is computationally sufficient for online usage. Therefore, this method can improve the success rate of such procedures as a percutaneous coronary intervention and provide the information necessary to diagnose cardiovascular diseases better.
Collapse
Affiliation(s)
- Siyeop Yoon
- 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul,Center for Healthcare Robotics, Korea Institute of Science and Technology, South Korea; 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul, KIST School, Korea University of Science and Technology, South Korea.
| | - Chang Hwan Yoon
- Gumi-ro, 82-gil 173, Bundang-gu, Seongnam, Seoul national university Bundang Hospital, South Korea.
| | - Deukhee Lee
- 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul,Center for Healthcare Robotics, Korea Institute of Science and Technology, South Korea; 5, Hwarang-ro 14-gil, Seongbuk-gu, Seoul, KIST School, Korea University of Science and Technology, South Korea.
| |
Collapse
|
8
|
Olch AJ, Alaei P. How low can you go? A CBCT dose reduction study. J Appl Clin Med Phys 2021; 22:85-89. [PMID: 33450139 PMCID: PMC7882101 DOI: 10.1002/acm2.13164] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 12/17/2020] [Accepted: 12/22/2020] [Indexed: 12/18/2022] Open
Abstract
Purpose Cone beam computed tomography (CBCT) is often used for patient setup based solely on bony anatomy. The goal of this work was to evaluate whether CBCT dose can be lowered to the level of kV image pair doses when used for bony anatomy‐based IGRT without compromising positioning accuracy. Methods An anthropomorphic phantom was CT scanned in the head, head and neck, chest, and pelvis regions and setup on the linear accelerator couch with the isocenter near the planned location. Cone beam computed tomographies were performed with the standard “full dose” protocol supplied by the linac vendor. With sequentially lowering the dose, three‐dimensional (3D) matching was performed for each without shifting the couch. The standard kV image pair protocol for each site was also used to image the phantoms. For all studies, six degrees of freedom was included in the 2D or 3D matching to the extent they could be employed. Imaging doses were determined in air at isocenter following the TG‐61 formalism. Results Cone beam computed tomography dose was reduced by 81–98% of the standard CBCT protocol to nearly that of the standard kV image pair dose for each site. Relative to the standard CBCT shift values, translational shifts were within 0.3 and 1.6 mm for all sites, for the reduced dose CBCT and kV image pair, respectively. Rotational shifts were within 0.2 degree and 0.7 degrees for all sites, for the reduced dose CBCTs and kV image pair, respectively. Conclusion For bony anatomy‐based image guidance, CBCT dose can be reduced to a value similar to that of a kV image pair with similar or better patient positioning accuracy than kV image pair alignment. Where rotations are important to correct, CBCT will be superior to orthogonal kV imaging without significantly increased imaging dose. This is especially important for image guidance for pediatric patient treatments.
Collapse
Affiliation(s)
- Arthur J Olch
- Radiation Oncology Program, Children's Hospital Los Angeles, Los Angeles, CA, USA
| | - Parham Alaei
- Department of Radiation Oncology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
9
|
Synthetic CT in assessment of anatomical and dosimetric variations in radiotherapy - procedure validation. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2020. [DOI: 10.2478/pjmpe-2020-0022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Abstract
Introduction: One of many procedures to control the quality of radiotherapy is daily imaging of the patient’s anatomy. The CBCT (Cone Beam Computed Tomography) plays an important role in patient positioning, and dose delivery monitoring. Nowadays, CBCT is a baseline for the calculation of fraction and total dose. Thus, it provides the potential for more comprehensive monitoring of the delivered dose and adaptive radiotherapy. However, due to the poor quality and the presence of numerous artifacts, the replacement of the CBCT image with the corrected one is desired for dose calculation. The aim of the study was to validate a method for generating a synthetic CT image based on deformable image registration.
Material and methods: A Head & Torso Freepoint phantom, model 002H9K (Computerized Imaging Reference Systems, Norfolk, USA) with inserts was imaged with CT (Computed Tomography). Then, contouring and treatment plan were created in Eclipse (Varian Medical Systems, Palo Alto, CA, USA) treatment planning system. The phantom was scanned again with the CBCT. The planning CT was registered and deformed to the CBCT, resulting in a synthetic CT in Velocity software (Varian Medical Systems, Palo Alto, CA, USA). The dose distribution was recalculated based on the created CT image.
Results: Differences in structure volumes and dose statistics calculated both on CT and synthetic CT were evaluated. Discrepancies between the original and delivered plan from 0.0 to 2.5% were obtained. Dose comparison was performed on the DVH (Dose-Volume Histogram) for all delineated inserts.
Conclusions: Our findings suggest the potential utility of deformable registration and synthetic CT for providing dose reconstruction. This study reports on the limitation of the procedure related to the limited length of the CBCT volume and deformable fusion inaccuracies.
Collapse
|
10
|
Bryce-Atkinson A, de Jong R, Bel A, Aznar MC, Whitfield G, van Herk M. Evaluation of Ultra-low-dose Paediatric Cone-beam Computed Tomography for Image-guided Radiotherapy. Clin Oncol (R Coll Radiol) 2020; 32:835-844. [PMID: 33067079 DOI: 10.1016/j.clon.2020.09.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 09/11/2020] [Accepted: 09/29/2020] [Indexed: 01/01/2023]
Abstract
AIMS In image-guided radiotherapy, daily cone-beam computed tomography (CBCT) is rarely applied to children due to concerns over imaging dose. Simulating low-dose CBCT can aid clinical protocol design by allowing visualisation of new scan protocols in patients without delivering additional dose. This work simulated ultra-low-dose CBCT and evaluated its use for paediatric image-guided radiotherapy by assessment of image registration accuracy and visual image quality. MATERIALS AND METHODS Ultra-low-dose CBCT was simulated by adding the appropriate amount of noise to projection images prior to reconstruction. This simulation was validated in phantoms before application to paediatric patient data. Scans from 20 patients acquired at our current clinical protocol (0.8 mGy) were simulated for a range of ultra-low doses (0.5, 0.4, 0.2 and 0.125 mGy) creating 100 scans in total. Automatic registration accuracy was assessed in all 100 scans. Inter-observer registration variation was next assessed for a subset of 40 scans (five scans at each simulated dose and 20 scans at the current clinical protocol). This subset was assessed for visual image quality by Likert scale grading of registration performance and visibility of target coverage, organs at risk, soft-tissue structures and bony anatomy. RESULTS Simulated and acquired phantom scans were in excellent agreement. For patient scans, bony atomy registration discrepancies for ultra-low-dose scans fell within 2 mm (translation) and 1° (rotation) compared with the current clinical protocol, with excellent inter-observer agreement. Soft-tissue registration showed large discrepancies. Bone visualisation and registration performance reached over 75% acceptability (rated 'well' or 'very well') down to the lowest doses. Soft-tissue visualisation did not reach this threshold for any dose. CONCLUSION Ultra-low-dose CBCT was accurately simulated and evaluated in patient data. Patient scans simulated down to 0.125 mGy were appropriate for bony anatomy set-up. The large dose reduction could allow for more frequent (e.g. daily) image guidance and, hence, more accurate set-up for paediatric radiotherapy.
Collapse
Affiliation(s)
- A Bryce-Atkinson
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK.
| | - R de Jong
- Department of Radiation Oncology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - A Bel
- Department of Radiation Oncology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - M C Aznar
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK; Clinical Trial Service Unit, Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - G Whitfield
- Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Manchester, UK; The Children's Brain Tumour Research Network, The University of Manchester, Royal Manchester Children's Hospital, Manchester, UK
| | - M van Herk
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| |
Collapse
|
11
|
Kuo HC, Lovelock MM, Li G, Ballangrud Å, Wolthuis B, Della Biancia C, Hunt MA, Berry SL. A phantom study to evaluate three different registration platform of 3D/3D, 2D/3D, and 3D surface match with 6D alignment for precise image-guided radiotherapy. J Appl Clin Med Phys 2020; 21:188-196. [PMID: 33184966 PMCID: PMC7769400 DOI: 10.1002/acm2.13086] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/09/2020] [Accepted: 10/09/2020] [Indexed: 12/03/2022] Open
Abstract
Purpose To evaluate two three‐dimensional (3D)/3D registration platforms, one two‐dimensional (2D)/3D registration method, and one 3D surface registration method (3DS). These three technologies are available to perform six‐dimensional (6D) registrations for image‐guided radiotherapy treatment. Methods Fiducial markers were asymmetrically placed on the surfaces of an anthropomorphic head phantom (n = 13) and a body phantom (n = 8), respectively. The point match (PM) solution to the six‐dimensional (6D) transformation between the two image sets [planning computed tomography (CT) and cone beam CT (CBCT)] was determined through least‐square fitting of the fiducial positions using singular value decomposition (SVD). The transformation result from SVD was verified and was used as the gold standard to evaluate the 6D accuracy of 3D/3D registration in Varian’s platform (3D3DV), 3D/3D and 2D/3D registration in the BrainLab ExacTrac system (3D3DE and 2D3D), as well as 3DS in the AlignRT system. Image registration accuracy from each method was quantitatively evaluated by root mean square of target registration error (rmsTRE) on fiducial markers and by isocenter registration error (IRE). The Wilcoxon signed‐rank test was utilized to compare the difference of each registration method with PM. A P < 0.05 was considered significant. Results rmsTRE was in the range of 0.4 mm/0.7 mm (cranial/body), 0.5 mm/1 mm, 1.0 mm/1.5 mm, and 1.0 mm/1.2 mm for PM, 3D3D, 2D3D, and 3DS, respectively. Comparing to PM, the mean errors of IRE were 0.3 mm/1 mm for 3D3D, 0.5 mm/1.4 mm for 2D3D, and 1.6 mm/1.35 mm for 3DS for the cranial and body phantoms respectively. Both of 3D3D and 2D3D methods differed significantly in the roll direction as compared to the PM method for the cranial phantom. The 3DS method was significantly different from the PM method in all three translation dimensions for both the cranial (P = 0.003–P = 0.03) and body (P < 0.001–P = 0.008) phantoms. Conclusion 3D3D using CBCT had the best image registration accuracy among all the tested methods. 2D3D method was slightly inferior to the 3D3D method but was still acceptable as a treatment position verification device. 3DS is comparable to 2D3D technique and could be a substitute for X‐ray or CBCT for pretreatment verification for treatment of anatomical sites that are rigid.
Collapse
Affiliation(s)
- Hsiang-Chi Kuo
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA.,Radiation Oncology Department, Norwalk Hospital, Norwalk, CT, USA
| | - Michael M Lovelock
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Guang Li
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Åse Ballangrud
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Brian Wolthuis
- Radiation Oncology Department, Norwalk Hospital, Norwalk, CT, USA
| | - Cesar Della Biancia
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Margie A Hunt
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Sean L Berry
- Medical Physics Department, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
12
|
van der Velden S, Bastiaannet R, Braat AJAT, Lam MGEH, Viergever MA, de Jong HWAM. Estimation of lung shunt fraction from simultaneous fluoroscopic and nuclear images. Phys Med Biol 2017; 62:8210-8225. [PMID: 28837044 DOI: 10.1088/1361-6560/aa8840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Radioembolisation with yttrium-90 (90Y) is increasingly used as a treatment of unresectable liver malignancies. For safety, a scout dose of technetium-99m macroaggregated albumin (99mTc-MAA) is used prior to the delivery of the therapeutic activity to mimic the deposition of 90Y. One-day procedures are currently limited by the lack of nuclear images in the intervention room. To cope with this limitation, an interventional simultaneous fluoroscopic and nuclear imaging device is currently being developed. The purpose of this simulation study was to evaluate the accuracy of estimating the lung shunt fraction (LSF) of the scout dose in the intervention room with this device and compare it against current clinical methods. METHODS A male and female XCAT phantom, both with two respiratory profiles, were used to simulate various LSFs resulting from a scout dose of 150 MBq 99mTc-MAA. Hybrid images were Monte Carlo simulated for breath-hold (5 s) and dynamic breathing (10 frames of 0.5 s) acquisitions. Nuclear images were corrected for attenuation with the fluoroscopic image and for organ overlap effects using a pre-treatment CT-scan. For comparison purposes, planar scintigraphy and mobile gamma camera images (both 300 s acquisition time) were simulated. Estimated LSFs were evaluated for all methods and compared to the phantom ground truth. RESULTS In the clinically relevant range of 10-20% LSF, hybrid imaging overestimated LSF with approximately 2 percentage points (pp) and 3 pp for the normal and irregular breathing phantoms, respectively. After organ overlap correction, LSF was estimated with a more constant error. Errors in planar scintigraphy and mobile gamma camera imaging were more dependent on LSF, body shape and breathing profile. CONCLUSION LSF can be estimated with a constant minor error with a hybrid imaging device. Estimated LSF is highly dependent on true LSF, body shape and breathing pattern when estimated with current clinical methods. The hybrid imaging device is capable of accurately estimating LSF within a few seconds in an interventional setting.
Collapse
Affiliation(s)
- Sandra van der Velden
- Radiology and Nuclear Medicine, UMC Utrecht, Mail E01.132, PO Box 85500, 3508 GA, Utrecht, Netherlands. Image Sciences Institute, UMC Utrecht, P.O. Box 85500, 3508 GA, Utrecht, Netherlands
| | | | | | | | | | | |
Collapse
|
13
|
Abstract
A method was developed to recognize anatomical site and image acquisition view automatically in 2D X-ray images that are used in image-guided radiation therapy. The purpose is to enable site and view dependent automation and optimization in the image processing tasks including 2D-2D image registration, 2D image contrast enhancement, and independent treatment site confirmation. The X-ray images for 180 patients of six disease sites (the brain, head-neck, breast, lung, abdomen, and pelvis) were included in this study with 30 patients each site and two images of orthogonal views each patient. A hierarchical multiclass recognition model was developed to recognize general site first and then specific site. Each node of the hierarchical model recognized the images using a feature extraction step based on principal component analysis followed by a binary classification step based on support vector machine. Given two images in known orthogonal views, the site recognition model achieved a 99% average F1 score across the six sites. If the views were unknown in the images, the average F1 score was 97%. If only one image was taken either with or without view information, the average F1 score was 94%. The accuracy of the site-specific view recognition models was 100%.
Collapse
|
14
|
Hunsche S, Sauner D, Majdoub FE, Neudorfer C, Poggenborg J, Goßmann A, Maarouf M. Intensity-based 2D 3D registration for lead localization in robot guided deep brain stimulation. Phys Med Biol 2017; 62:2417-2426. [DOI: 10.1088/1361-6560/aa5ecd] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
Xu H, Brown S, Chetty IJ, Wen N. A Systematic Analysis of Errors in Target Localization and Treatment Delivery for Stereotactic Radiosurgery Using 2D/3D Image Registration. Technol Cancer Res Treat 2016; 16:321-331. [PMID: 27582369 DOI: 10.1177/1533034616664425] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE To determine the localization uncertainties associated with 2-dimensional/3-dimensional image registration in comparison to 3-dimensional/3-dimensional image registration in 6 dimensions on a Varian Edge Linac under various imaging conditions. METHODS The systematic errors in 6 dimensions were assessed by comparing automatic 2-dimensional/3-dimensional (kV/MV vs computed tomography) with 3-dimensional/3-dimensional (cone beam computed tomography vs computed tomography) image registrations under various conditions encountered in clinical applications. The 2-dimensional/3-dimensional image registration uncertainties for 88 patients with different treatment sites including intracranial and extracranial were evaluated by statistically analyzing 2-dimensional/3-dimensional pretreatment verification shifts of 192 fractions in stereotactic radiosurgery and stereotactic body radiotherapy. RESULTS The systematic errors of 2-dimensional/3-dimensional image registration using kV-kV, MV-kV, and MV-MV image pairs were within 0.3 mm and 0.3° for the translational and rotational directions within a 95% confidence interval. No significant difference ( P > .05) in target localization was observed with various computed tomography slice thicknesses (0.8, 1, 2, and 3 mm). Two-dimensional/3-dimensional registration had the best accuracy when pattern intensity and content filter were used. For intracranial sites, means ± standard deviations of translational errors were -0.20 ± 0.70 mm, 0.04 ± 0.50 mm, and 0.10 ± 0.40 mm for the longitudinal, lateral, and vertical directions, respectively. For extracranial sites, means ± standard deviations of translational errors were -0.04 ± 1.00 mm, 0.2 ± 1.0 mm, and 0.1 ± 1.0 mm for the longitudinal, lateral, and vertical directions, respectively. Two-dimensional/3-dimensional image registration for intracranial and extracranial sites had comparable systematic errors that were approximately 0.2 mm in the translational direction and 0.08° in the rotational direction. CONCLUSION The standard 2-dimensional/3-dimensional image registration tool available on the Varian Edge radiosurgery device, a state-of-the-art system, is helpful for robust and accurate target positioning for image-guided stereotactic radiosurgery.
Collapse
Affiliation(s)
- Hao Xu
- 1 Department of Oncology, Wayne State University, Detroit, MI, USA
| | - Stephen Brown
- 2 Department of Radiation Oncology, Henry Ford Hospital, Detroit, MI, USA
| | - Indrin J Chetty
- 2 Department of Radiation Oncology, Henry Ford Hospital, Detroit, MI, USA
| | - Ning Wen
- 2 Department of Radiation Oncology, Henry Ford Hospital, Detroit, MI, USA
| |
Collapse
|
16
|
Boman E, Kapanen M, Laaksomaa M, Mäenpää H, Hyödynmaa S, Kellokumpu-Lehtinen PL. Treatment accuracy without rotational setup corrections in intracranial SRT. J Appl Clin Med Phys 2016; 17:86-94. [PMID: 27455488 PMCID: PMC5690032 DOI: 10.1120/jacmp.v17i4.6149] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 02/23/2016] [Accepted: 02/22/2016] [Indexed: 11/30/2022] Open
Abstract
The aim of this study was to evaluate the impact of actual rotational setup errors on dose distributions in intracranial stereotactic radiotherapy (SRT) with different alternatives for treatment position selection. A total of 38 SRT fractions from 18 patients were retrospectively evaluated with rotational setup errors obtained from actual treatments. The planning computed tomography (CT) images were rotated according to online cone‐beam CT (CBCT) images and the dose distribution was recalculated to the rotated CT images using three different patient positionings derived from: 1) an automatic 6D match neglecting rotation correction (Auto6D); 2) an automatic 3D match (Auto3D); and 3) a manual 3D match from actual treatment (Treat3D). The mean conformity index (CI) was 0.92 for the original plans and 0.91 for the Auto6D plans. The mean CI decreased significantly (p<0.01) to 0.78 and 0.80 for the Auto3D and the Treat3D plans, respectively. The mean minimum dose of the planning target volume (PTVmin) was 91.9% of the prescribed dose for the original plans and 92.1% for the Auto6D plans, while for the Auto3D and the Treat3D plans PTVmin decreased significantly (p<0.01) to 78.9% and 80.2%, respectively. No significant differences were seen between the Auto6D and the original treatment plans in terms of the dose parameters. However, the Auto3D and the Treat3D plans were statistically significantly inferior (p<0.01) to the Auto6D and the original plans. In addition, a significant negative correlation (p<0.01,|r|>0.38) was found in the Auto3D and the Treat3D cases between the rotation error and CI, PTVmin or minimum dose of gross tumour volume. In SRT, a treatment plan of comparable quality to 6D rotation correction can be achieved by using 6D registration without a rotational correction in the selection of patient positioning. This was demonstrated for typical rotation errors seen in clinical practice. PACS number(s): 87.55, 87.57
Collapse
|