1
|
Atosuo J, Karhuvaara O, Suominen E, Virtanen J, Vilén L, Nuutila J. The role of gamma globulin, complement component 1q, factor B, properdin, body temperature, C-reactive protein and serum amyloid alpha to the activity and the function of the human complement system and its pathways. J Immunol Methods 2024; 531:113709. [PMID: 38862098 DOI: 10.1016/j.jim.2024.113709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 05/20/2024] [Accepted: 06/08/2024] [Indexed: 06/13/2024]
Abstract
The complement system plays a crucial role in orchestrating the activation and regulation of inflammation within the human immune system. Three distinct activation pathways-classical, lectin, and alternative-converge to form the common lytic pathway, culminating in the formation of the membrane-attacking complex that disrupts the structure of pathogens. Dysregulated complement system activity can lead to tissue damage, autoimmune diseases, or immune deficiencies. In this study, the antimicrobial activity of human serum was investigated by using a bioluminescent microbe probe, Escherichia coli (pEGFPluxABCDEamp). This probe has previously been used to determine the antimicrobial activity of complement system and the polymorphonuclear neutrophils. In this study, blocking antibodies against key serum activators and components, including IgG, complement component 1q, factor B, and properdin, were utilized. The influence of body temperature and acute phase proteins, such as C reactive protein (CRP) and serum amyloid alpha (SAA), on the complement system was also examined. The study reveals the critical factors influencing complement system activity and pathway function. Alongside crucial factors like C1q and IgG, alternative pathway components factor B and properdin played pivotal roles. Results indicated that the alternative pathway accounted for approximately one third of the overall serum antimicrobial activity, and blocking this pathway disrupted the entire complement system. Contrary to expectations, elevated body temperature during inflammation did not enhance the antimicrobial activity of human serum. CRP demonstrated complement activation properties, but at higher physiological concentrations, it exhibited antagonistic tendencies, dampening the response. On the other hand, SAA enhanced the serum's activity. Overall, this study sheds a light on the critical factors affecting both complement system activity and pathway functionality, emphasizing the importance of a balanced immune response.
Collapse
Affiliation(s)
- Janne Atosuo
- Laboratory of Immunochemistry, Department of Life Technologies, Faculty of Technology, University of Turku, 20140, Finland.
| | - Outi Karhuvaara
- Laboratory of Immunochemistry, Department of Life Technologies, Faculty of Technology, University of Turku, 20140, Finland.
| | - Eetu Suominen
- Laboratory of Immunochemistry, Department of Life Technologies, Faculty of Technology, University of Turku, 20140, Finland.
| | - Julia Virtanen
- Laboratory of Immunochemistry, Department of Life Technologies, Faculty of Technology, University of Turku, 20140, Finland
| | - Liisa Vilén
- Department of Occupational Medicine, Clinical Department, Faculty of Medicine, 20140, University of Turku, Finland.
| | - Jari Nuutila
- Laboratory of Immunochemistry, Department of Life Technologies, Faculty of Technology, University of Turku, 20140, Finland.
| |
Collapse
|
2
|
Karhuvaara O, Vilén L, Nuutila J, Putus T, Atosuo J. Indoor microbial exposure increases complement component C3a and C-reactive protein concentrations in serum. Heliyon 2024; 10:e24104. [PMID: 38293363 PMCID: PMC10827445 DOI: 10.1016/j.heliyon.2024.e24104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 01/02/2024] [Accepted: 01/03/2024] [Indexed: 02/01/2024] Open
Abstract
Indoor exposure to microbial growth, caused by moisture damage, has been an established health risk for several decades. It is likely that a damp indoor environment contains biological pollutants that trigger both the innate and adaptive branches of the immune system. In this study, we investigated the association between moisture damage related microbial exposure and serum C3a, C5a and CRP concentrations in Finnish adults. Serum C3a and CRP concentrations were elevated in individuals exposed to moisture damage and microbial growth in an indoor air environment. The elevated concentrations may be due to environmental factors present in moisture-damaged buildings. Complement activation and the resulting proinflammatory cleavage products may be a driving factor in inflammatory responses following exposure to indoor moisture damage and related microbial growth.
Collapse
Affiliation(s)
- Outi Karhuvaara
- The Laboratory of Immunochemistry, Department of Biotechnology, Faculty of Science and Engineering, University of Turku, Turku, Finland
- Environmental Medicine and Occupational Health, Department of Clinical Medicine, Faculty of Medicine, University of Turku, Turku, Finland
| | - Liisa Vilén
- Environmental Medicine and Occupational Health, Department of Clinical Medicine, Faculty of Medicine, University of Turku, Turku, Finland
| | - Jari Nuutila
- The Laboratory of Immunochemistry, Department of Biotechnology, Faculty of Science and Engineering, University of Turku, Turku, Finland
| | - Tuula Putus
- Environmental Medicine and Occupational Health, Department of Clinical Medicine, Faculty of Medicine, University of Turku, Turku, Finland
| | - Janne Atosuo
- The Laboratory of Immunochemistry, Department of Biotechnology, Faculty of Science and Engineering, University of Turku, Turku, Finland
- Environmental Medicine and Occupational Health, Department of Clinical Medicine, Faculty of Medicine, University of Turku, Turku, Finland
| |
Collapse
|
3
|
Madsen AM, Moslehi-Jenabian S, Frankel M, White JK, Frederiksen MW. Airborne bacterial species in indoor air and association with physical factors. UCL OPEN ENVIRONMENT 2023; 5:e056. [PMID: 37229345 PMCID: PMC10208329 DOI: 10.14324/111.444/ucloe.000056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 02/25/2023] [Indexed: 05/27/2023]
Abstract
The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in five homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis and Paracoccus yeei. The concentrations of Gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila and B. pumilus were associated positively with relative humidity (RH), and concentrations of K. rhizophila were associated negatively with temperature and air change rate (ACR). Micrococcus flavus concentrations were associated negatively with ACR. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, ACR and RH.
Collapse
Affiliation(s)
- Anne Mette Madsen
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
| | - Saloomeh Moslehi-Jenabian
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
| | - Mika Frankel
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
| | - John Kerr White
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
- Division of Clinical Microbiology, Karolinska University Hospital, Stockholm, Sweden
| | - Margit W. Frederiksen
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
| |
Collapse
|
4
|
Gordon Holzheimer R. Moisture damage and fungal contamination in buildings are a massive health threat - a surgeon's perspective. Cent Eur J Public Health 2023; 31:63-68. [PMID: 37086423 DOI: 10.21101/cejph.a7504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 02/20/2023] [Indexed: 04/23/2023]
Abstract
OBJECTIVES Indoor air toxicity is of major public health concern due to the increase in humidity-induced indoor mould exposure and associated health changes. The objective is to present evidence for the causality of health threats and indoor mould exposure. METHODS PubMed search on the following keywords: dampness, mould, indoor air quality, public health, dampness, and mould hypersensitivity syndrome, sick building syndrome, and building-related illness as well as information from the health authorities of Bavaria and North Rhine-Westphalia, the Center of Disease Control (CDC), World Health Organisation (WHO), and guidelines of professional societies. RESULTS The guidelines of professional societies published in 2017 are decisive for the assessment of the impact of mould pollution caused by moisture damage on human health and for official regulations in Germany. Until 2017, a causal connection between moisture damage and mould exposure could usually only be established for pulmonary diseases. The health risk of fungal components is apparent as documented in the fungal priority pathogens list (FPPL) of the WHO. Since 2017, studies, especially in Scandinavia, have proved causality between moisture and mould exposure not only for pulmonary diseases but also for extrapulmonary diseases and symptoms. This was made possible by new test methods for determining the toxicity of fungal components in indoor air. Environmental medical syndromes, e.g., dampness and mould hypersensitivity syndrome (DMHS), sick building syndrome (SBS), building-related symptoms (BRS), and building-related illness (BRI), and fungal pathogens, e.g., Aspergillus fumigatus, pose a major threat to public health. CONCLUSION There is evidence for the causality of moisture-induced indoor moulds and severe health threats in these buildings. According to these findings, it is no longer justifiable to ignore or trivialize the mould contamination induced by moisture damage and its effects on pulmonary and extrapulmonary diseases. The health and economic implications of these attitudes are clear.
Collapse
|
5
|
Andersson (AMA, Salo J, Mikkola R, Marik T, Kredics L, Kurnitski J, Salonen H. Melinacidin-Producing Acrostalagmus luteoalbus, a Major Constituent of Mixed Mycobiota Contaminating Insulation Material in an Outdoor Wall. Pathogens 2021; 10:pathogens10070843. [PMID: 34357993 PMCID: PMC8308789 DOI: 10.3390/pathogens10070843] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 06/28/2021] [Accepted: 06/29/2021] [Indexed: 11/16/2022] Open
Abstract
Occupants may complain about indoor air quality in closed spaces where the officially approved standard methods for indoor air quality risk assessment fail to reveal the cause of the problem. This study describes a rare genus not previously detected in Finnish buildings, Acrostalagmus, and its species A. luteoalbus as the major constituents of the mixed microbiota in the wet cork liner from an outdoor wall. Representatives of the genus were also present in the settled dust in offices where occupants suffered from symptoms related to the indoor air. One strain, POB8, was identified as A. luteoalbus by ITS sequencing. The strain produced the immunosuppressive and cytotoxic melinacidins II, III, and IV, as evidenced by mass spectrometry analysis. In addition, the classical toxigenic species indicating water damage, mycoparasitic Trichoderma, Aspergillus section Versicolores, Aspergillus section Circumdati, Aspergillus section Nigri, and Chaetomium spp., were detected in the wet outdoor wall and settled dust from the problematic rooms. The offices exhibited no visible signs of microbial growth, and the airborne load of microbial conidia was too low to explain the reported symptoms. In conclusion, we suggest the possible migration of microbial bioactive metabolites from the wet outdoor wall into indoor spaces as a plausible explanation for the reported complaints.
Collapse
Affiliation(s)
- (Aino) Maria A. Andersson
- Department of Civil Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland; (J.S.); (R.M.); (J.K.); (H.S.)
- Correspondence: ; Tel.: +358-405508934
| | - Johanna Salo
- Department of Civil Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland; (J.S.); (R.M.); (J.K.); (H.S.)
| | - Raimo Mikkola
- Department of Civil Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland; (J.S.); (R.M.); (J.K.); (H.S.)
| | - Tamás Marik
- Department of Microbiology, Faculty of Science and Informatics, University of Szeged, Közép fasor 52, H-6726 Szeged, Hungary; (T.M.); (L.K.)
| | - László Kredics
- Department of Microbiology, Faculty of Science and Informatics, University of Szeged, Közép fasor 52, H-6726 Szeged, Hungary; (T.M.); (L.K.)
| | - Jarek Kurnitski
- Department of Civil Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland; (J.S.); (R.M.); (J.K.); (H.S.)
- Department of Civil Engineering and Architecture, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia
| | - Heidi Salonen
- Department of Civil Engineering, Aalto University, P.O. Box 12100, FI-00076 Aalto, Finland; (J.S.); (R.M.); (J.K.); (H.S.)
- International Laboratory for Air Quality and Health, Queensland University of Technology, 2 George Street, Brisbane, QLD 4001, Australia
| |
Collapse
|