• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4591707)   Today's Articles (1498)   Subscriber (49313)
For: Macleod K, Katz LB, Cameron H. Capillary and Venous Blood Glucose Accuracy in Blood Glucose Meters Versus Reference Standards: The Impact of Study Design on Accuracy Evaluations. J Diabetes Sci Technol 2019;13:546-552. [PMID: 30084263 PMCID: PMC6501528 DOI: 10.1177/1932296818790228] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Number Cited by Other Article(s)
1
Reliability and accuracy of bedside capillary blood glucose measurement by glucometers compared to venous blood glucose in critically ill patients: A facility based cross-sectional study. Clin Nutr ESPEN 2024;60:24-30. [PMID: 38479916 DOI: 10.1016/j.clnesp.2024.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 12/04/2023] [Accepted: 01/06/2024] [Indexed: 04/12/2024]
2
Instrument-free single-step direct estimation of the plasma glucose level from one drop of blood using smartphone-interfaced analytics on a paper strip. LAB ON A CHIP 2022;22:4666-4679. [PMID: 36345815 DOI: 10.1039/d2lc00824f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
3
Landscape of Continuous Glucose Monitoring (CGM) and Integrated CGM: Accuracy Considerations. Diabetes Technol Ther 2021;23:S5-S11. [PMID: 34546084 DOI: 10.1089/dia.2021.0236] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
4
Evidence From a Long-Term, Systematic Post-Market Surveillance Program: Clinical Performance of a Hematocrit-Insensitive Blood Glucose Test Strip. J Diabetes Sci Technol 2021;15:67-75. [PMID: 30730221 PMCID: PMC7783001 DOI: 10.1177/1932296819826968] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
5
Analysis of "Capillary and Venous Blood Glucose Accuracy in Blood Glucose Meters Versus Reference Standards: The Impact of Study Design on Accuracy Evaluations". J Diabetes Sci Technol 2019;13:553-558. [PMID: 30222000 PMCID: PMC6501518 DOI: 10.1177/1932296818799365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
6
Why the Details of Glucose Meter Evaluations Matters. J Diabetes Sci Technol 2019;13:559-560. [PMID: 30328716 PMCID: PMC6501532 DOI: 10.1177/1932296818803113] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
7
Measures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices. J Diabetes Sci Technol 2019;13:575-583. [PMID: 30453761 PMCID: PMC6501529 DOI: 10.1177/1932296818812062] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA