1
|
Barnes H, Alexander S, Bower L, Ehlers J, Gani C, Herbert T, Lawes R, Møller PK, Morgan T, Nowee ME, Smith G, van Triest B, Tyagi N, Whiteside L, McNair H. Development and results of a patient-reported treatment experience questionnaire on a 1.5 T MR-Linac. Clin Transl Radiat Oncol 2021; 30:31-37. [PMID: 34307911 PMCID: PMC8283148 DOI: 10.1016/j.ctro.2021.06.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 06/02/2021] [Accepted: 06/23/2021] [Indexed: 12/16/2022] Open
Abstract
INTRODUCTION With the implementation of new radiotherapy technology, it is imperative that patient experience is investigated alongside efficacy and outcomes. This paper presents the development of a specifically designed validated questionnaire and a first report of international multi-institutional preliminary patient experience of MRI-guided adaptive radiotherapy (MRgART) on the 1.5 T MR-Linac (MRL). METHODS A patient experience questionnaire was developed and validated before being distributed to the Elekta MRL Consortium, to gather first patient-reported experience from participating centres worldwide. The final version of the questionnaire contains 18 questions covering a range of themes and was scored on a Likert scale of 0-3. Responses were post-processed so that a score of 0 represents a negative response and 3 represents the most favourable response. These results were analysed for patient-reported experience of treatment on the MRL. Results were also analysed for internal consistency of the questionnaire using Chronbach's Alpha and the questionnaire contents were validated for relevance using content validity indexes (CVI). RESULTS 170 responses were received from five centres, representing patients with a wide range of tumour treatment sites from four different countries. MRgART was well tolerated with an 84% favourable response across all questions and respondents. When analysed by theme, all reported the highest percentage of results in the favourable categories (2 and 3). Internal consistency in the questionnaire was high (Cronbach's α = 0.8) and the item-level CVI for each question was 0.78 or above and the Scale-level CVI was 0.93, representing relevant content. CONCLUSION The developed questionnaire has been validated as relevant and appropriate for use in reporting experience of patients undergoing treatment on the MRL. The overall patient-reported experience and satisfaction from multiple centres within the Elekta MRL Consortium was consistently high. These results can reinforce user confidence in continuing to expand and develop MRL use in adaptive radiotherapy.
Collapse
Affiliation(s)
- Helen Barnes
- Royal Marsden NHS Foundation Trust, United Kingdom
| | | | - Lorna Bower
- Royal Marsden NHS Foundation Trust, United Kingdom
- Institute of Cancer Research, United Kingdom
| | - Jakob Ehlers
- Department for Radiation Oncology, University Hospital Tübingen, Tübingen, Germany
| | - Cihan Gani
- Department for Radiation Oncology, University Hospital Tübingen, Tübingen, Germany
| | | | | | | | - Toby Morgan
- Royal Marsden NHS Foundation Trust, United Kingdom
- Institute of Cancer Research, United Kingdom
| | | | | | | | - Neelam Tyagi
- Memorial Sloan Kettering Cancer Centre, United States
| | | | - Helen McNair
- Royal Marsden NHS Foundation Trust, United Kingdom
- Institute of Cancer Research, United Kingdom
| |
Collapse
|
2
|
Mulla Z, Hashem RM, Almohamad A, Boubakra T, Almerdhemah H, Kunjappan A, Jastaniah Z. A comparison between two different immobilization devices for radiation therapy treatment of pelvic cancer using VMAT. J Med Imaging Radiat Sci 2021; 52:238-247. [PMID: 33741280 DOI: 10.1016/j.jmir.2021.02.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 01/24/2021] [Accepted: 02/22/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVES To assess setup reproducibility of low kneefix with feetfix (LKF-FF) system and its operator-reported convenience by reference to low dual leg positioner (LDLP), among patients treated with pelvic radiotherapy. METHODS A retrospective controlled trial was carried out at the radiotherapy unit. It included patients who underwent radical radiotherapy to the pelvis using VMAT, and who benefitted from LDLP (N = 30) or LKF-FF (N = 30) immobilization system. Average absolute shifts (AAS) and total vector errors (TVE) were computed and compared between the two systems, using translational (lateral, longitudinal and vertical) and rotational (X, Y and Z planes) directions. Accuracy rates were computed on pooled data including 1529 VMAT images, 819 in LDLP and 710 in LKF-FF groups, using different cutoffs. Radiotherapists' subjective assessment of the device's ease of setup, handling, cleaning, and storage, and patient comfort was carried out comparatively between the two devices. RESULTS No statistically significant difference was observed between the two systems in systematic settings, while LKF-FF outperformed LDLP in random settings; notably in vertical translation and X and Z rotational shifts. Analysis of TVEs showed significant decrease in rotational TVE in LKF-FF group (mean=1.38° versus 2.38, p = 0.003) by reference to LDLP, respectively; however, both systems had comparable translational TVE (p = 0.590). In pooled analysis, LKF-FF enabled an overall increase in setup accuracy rates in rotational directions by up to 15% and 19% at ±1° and ±2° accuracy levels, respectively (p<0.05). Subjective assessments showed that the two immobilization systems were comparable regarding all investigated dimensions; however, the overall radiotherapists' preference leaned toward LDLP. CONCLUSION The newly implemented LKF-FF system outperformed LDLP in terms of setup reproducibility, notably in rotational directions, where it enhanced setup accuracy rates by up to 19%. Long-term use of LKF-FF may improve the users' satisfaction.
Collapse
Affiliation(s)
- Zaheeda Mulla
- Department of Oncology, King Faisal Specialist Hospital and Research Center, P.O Box 40047, 21499 Jeddah, Saudi Arabia.
| | - Rania M Hashem
- Department of Radiology, King Abdulaziz University Hospital, P.O Box 21589, Jeddah, Saudi Arabia.
| | - Abdullah Almohamad
- Department of Oncology, King Faisal Specialist Hospital and Research Center, P.O Box 40047, 21499 Jeddah, Saudi Arabia.
| | - Tarik Boubakra
- Department of Oncology, King Faisal Specialist Hospital and Research Center, P.O Box 40047, 21499 Jeddah, Saudi Arabia.
| | - Hussain Almerdhemah
- Department of Oncology, King Faisal Specialist Hospital and Research Center, P.O Box 40047, 21499 Jeddah, Saudi Arabia.
| | - Anila Kunjappan
- Department of Radiology, King Abdulaziz University Hospital, P.O Box 21589, Jeddah, Saudi Arabia.
| | - Zayd Jastaniah
- Department of Radiology, King Abdulaziz University Hospital, P.O Box 21589, Jeddah, Saudi Arabia.
| |
Collapse
|
3
|
Dosimetric evaluation of whole-pelvis radiation therapy of prostate cancers: clinical experience. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396920000461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AbstractBackground:The standard treatment modalities for prostate cancer include surgery, chemotherapy, hormonal therapy and radiation therapy or any combination depending on the stage of the tumour. Radiation therapy is a common and effective treatment modality for low-intermediate-risk patients with localised prostate cancer, to treat the intact prostate and seminal vesicles or prostate bed post prostatectomy. However, for high-risk patients with lymph node involvement, treatment with radiation will usually include treatment of the whole pelvis to cover the prostate and seminal vesicles or prostate bed and the pelvic lymph nodes followed by a boost delivery dose to the prostate and seminal vesicles or prostate bed.Materials and Methods:We retrospectively analysed the treatment plans for 179 prostate cancer patients treated at the cancer centre with the volumetric-modulated arc therapy (VMAT) technique via RapidArc using 6 MV photon beam. Patients were either treated with a total prescription dose of 78 Gy in 39 fractions for patients with intact prostate or 66 Gy in 33 fractions for post prostatectomy patients.Results:There were 114 (64%) patients treated with 78 Gy/39 and 65 (36%) treated with 66 Gy/34. The mean homogeneity index (HI), conformity index (CI) and uniformity index (UI) for the PTV-primary of patients treated with 78 Gy are 0.06 ± 0.01, 1.04 ± 0.01 and 0.99 ± 0.01, respectively, and the corresponding mean values for patients treated with 66 Gy are 0.06 ± 0.02, 1.05 ± 0.01 and 0.99 ± 0.01, respectively. The mean PTV-primary V95%, V100% and V105% are 99.5 ± 0.5%, 78.8 ± 12.2% and 0.1 ± 0.5%, respectively, for patients treated with 78 Gy and 99.3 ± 0.9%, 78.1 ± 10.6% and 0.1 ± 0.4%, respectively, for patients treated with 66 Gy. The rectal V50Gy, V65Gy, V66.6Gy, V70Gy, V75Gy and V80Gy are 26.8 ± 9.1%, 14.2 ± 5.3%, 13.1 ± 5.0%, 10.8 ± 4.3%, 6.9 ± 3.1% and 0.1 ± 0.1%, respectively, for patients treated with 78 Gy and 33.7 ± 8.4%, 14.1 ± 4.5%, 6.7 ± 4.5%, 0.0 ± 0.2%, 0.0% and 0.0%, respectively, for patients treated with 66 Gy.Conclusion:The use of VMAT technique for radiation therapy of high-risk prostate cancer patients is an efficient and reliable method for achieving superior dose conformity, uniformity and homogeneity to the PTV and minimal doses to the organs at risk. Results from this study provide the basis for the development and implementation of consistent treatment criteria in radiotherapy programs, have the potential to establish an evaluation process to define a consistent, standardised and transparent treatment path for all patients that reduces significant variations in the acceptability of treatment plans and potentially improve patient standard of care.
Collapse
|
4
|
He P, Mori S. Perturbation analysis of 4D dose distribution for scanned carbon-ion beam radiotherapy. Phys Med 2020; 74:74-82. [PMID: 32442912 DOI: 10.1016/j.ejmp.2020.05.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 04/27/2020] [Accepted: 05/05/2020] [Indexed: 01/18/2023] Open
Abstract
PURPOSE To evaluate the patients' set-up error-induced perturbation effects on 4D dose distributions (4DDD) of range-adapted internal target volume-based (raITV) treatment plan using lung and liver 4DCT data sets. METHODS We enrolled 20 patients with lung and liver cancer treated with respiratory-gated carbon-ion beam scanning therapy. PTVs were generated by adding a 2 mm range-adapted set-up margin on the raITVs. Set-up errors were simulated by shifting the beam isocenter in three translational directions of ±2 mm, ±4 mm, and ±6 mm. 4DDDs were calculated for both nominal and isocenter-shifted situations. Dose metrics of CTV dose coverage (D95) and normal tissue sparing were evaluated. Statistical significance with p < 0.01 was considered by Wilcoxon signed rank test. RESULTS The CTV dose coverage was more sensitive to set-up errors for lung cases than for liver cases, and more serious in superior-inferior direction. The sufficient CTV-D95 > 98% could be achieved with set-up errors less than ±2 mm in all shift directions both for lung and liver cases. With the increase of set-up error, the CTV dose coverage decreased gradually. The clinical criterial of CTV-D95 > 95% could not be fulfilled with set-up error reached to ±4 mm for lung cases, and ±6 mm for liver cases. OAR doses did not have a significant difference with each set-up error for both lung and liver cases. CONCLUSIONS The range-adapted set-up margin successfully prevented dose degradation of 4DDDs in the presence of the same magnitude of set-up error for raITV-based carbon-ion beam scanning therapy.
Collapse
Affiliation(s)
- Pengbo He
- Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba, Japan; University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Shinichiro Mori
- Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba, Japan
| |
Collapse
|
5
|
Okada W, Tanooka M, Sano K, Shibata M, Doi H, Miyazaki M, Nakahara R, Sueoka M, Suzuki H, Fujiwara M, Inomata T, Yamakado K. Couch modeling optimization for tomotherapy planning and delivery. J Appl Clin Med Phys 2019; 20:114-121. [PMID: 31343831 PMCID: PMC6698767 DOI: 10.1002/acm2.12686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Revised: 05/26/2019] [Accepted: 07/07/2019] [Indexed: 11/08/2022] Open
Abstract
We sought to validate new couch modeling optimization for tomotherapy planning and delivery. We constructed simplified virtual structures just above a default setting couch through a planning support system (MIM Maestro, version 8.2, MIM Software Inc, Cleveland, OH, USA). Based on ionization chamber measurements, we performed interactive optimization and determined the most appropriate physical density of these virtual structures in a treatment planning system (TPS). To validate this couch optimization, Gamma analysis and these statistical analyses between a three-dimensional diode array QA system (ArcCHECK, Sun Nuclear, Melbourne, FL, USA) results and calculations from ionization chamber measurements were performed at 3%/2 mm criteria with a threshold of 10% in clinical QA plans. Using a virtual model consisting of a center slab density of 4.2 g/cm3 and both side slabs density of 1.9 g/cm3 , we demonstrated close agreement between measured dose and the TPS calculated dose. Agreement was within 1% for all gantry angles at the isocenter and within 2% in off-axis plans. In validation of the couch modeling in a clinical QA plan, the average gamma passing rate improved approximately 0.6%-5.1%. It was statistically significant (P < 0.05) for all treatment sites. We successfully generated an accurate couch model for a TomoTherapy TPS by interactively optimizing the physical density of the couch using a planning support system. This modeling proved to be an efficient way of correcting the dosimetric effects of the treatment couch in tomotherapy planning and delivery.
Collapse
Affiliation(s)
- Wataru Okada
- Department of RadiologyHyogo College of MedicineNishinomiyaJapan
- Department of RadiotherapyTakarazuka City HospitalTakarazukaJapan
| | - Masao Tanooka
- Department of RadiologyHyogo College of MedicineNishinomiyaJapan
- Department of RadiotherapyTakarazuka City HospitalTakarazukaJapan
| | - Keisuke Sano
- Department of RadiotherapyTakarazuka City HospitalTakarazukaJapan
| | - Mayuri Shibata
- Department of RadiotherapyTakarazuka City HospitalTakarazukaJapan
| | - Hiroshi Doi
- Department of RadiologyHyogo College of MedicineNishinomiyaJapan
- Department of Radiation OncologyKindai University Faculty of MedicineSayamaJapan
| | | | - Ryuta Nakahara
- Department of RadiologyHyogo College of MedicineNishinomiyaJapan
| | - Masaki Sueoka
- Department of RadiologyHyogo College of MedicineNishinomiyaJapan
| | - Hitomi Suzuki
- Department of RadiologyHyogo College of MedicineNishinomiyaJapan
| | | | - Taisuke Inomata
- Department of RadiotherapyTakarazuka City HospitalTakarazukaJapan
| | | |
Collapse
|
6
|
Li W, Jiang Z, Chu K, Jin J, Ge Y, Cai J. A Noninvasive Method to Reduce Radiotherapy Positioning Error Caused by Respiration for Patients With Abdominal or Pelvic Cancers. Technol Cancer Res Treat 2019; 18:1533033819825865. [PMID: 30803363 PMCID: PMC6378633 DOI: 10.1177/1533033819825865] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Purpose: To develop an infrared optical method of reducing surface-based registration error caused by respiration to improve radiotherapy setup accuracy for patients with abdominal or pelvic tumors. Materials and Methods: Fifteen patients with abdominal or pelvic tumors who received radiation therapy were prospectively included in our study. All patients were immobilized with vacuum cushion and underwent cone-beam computed tomography to validate positioning error before treatment. For each patient, after his or her setup based on markers fixed on immobilization device, initial positioning errors in patient left-right, anterior-posterior, and superior-inferior directions were validated by cone-beam computed tomography. Then, our method calculated mismatch between patient and immobilization device based on surface registration by interpolating between expiratory- and inspiratory-phase surface to find the specific phase to best match the surface in planning computed tomography scans. After adjusting the position of treatment couch by the shift proposed by our method, a second cone-beam computed tomography was performed to determine the final positioning error. A comparison between initial and final setup error will be made to validate the effectiveness of our method. Results: Final positioning error confirmed by cone-beam computed tomography is 1.59 (1.82), 1.61 (1.84), and 1.31 (1.38) mm, reducing initial setup error by 24.52%, 51.04%, and 53.63% in patient left-right, anterior-posterior, and superior-inferior directions, respectively. Wilcoxon test showed that our method significantly reduced the 3-dimensional distance of positioning error (P < .001). Conclusion: Our method can significantly improve the setup precision for patients with abdominal or pelvic tumors in a noninvasive way by reducing the surface-based registration error caused by respiration.
Collapse
Affiliation(s)
- Weifeng Li
- 1 School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Zhuoran Jiang
- 1 School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Kaiyue Chu
- 2 Department of Radiotherapy, Nantong Tumor Hospital, Nantong, China
| | - Jianhua Jin
- 2 Department of Radiotherapy, Nantong Tumor Hospital, Nantong, China
| | - Yun Ge
- 1 School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Jing Cai
- 2 Department of Radiotherapy, Nantong Tumor Hospital, Nantong, China
| |
Collapse
|
7
|
Kanai T, Furuichi W, Mori S. Evaluation of patient positional reproducibility on the treatment couch and its impact on dose distribution using rotating gantry system in scanned carbon-ion beam therapy. Phys Med 2019; 57:160-168. [DOI: 10.1016/j.ejmp.2018.12.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 11/30/2018] [Accepted: 12/17/2018] [Indexed: 11/28/2022] Open
|
8
|
Udayashankar AH, Noorjahan S, Srikantia N, Babu KR, Muzumder S. Immobilization versus no immobilization for pelvic external beam radiotherapy. Rep Pract Oncol Radiother 2018; 23:233-241. [PMID: 29991927 DOI: 10.1016/j.rpor.2018.04.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Revised: 12/23/2017] [Accepted: 04/12/2018] [Indexed: 10/16/2022] Open
Abstract
Aim To identify the most reproducible technique of patient positioning and immobilization during pelvic radiotherapy. Background Radiotherapy plays an important role in the treatment of pelvic malignancies. Errors in positioning of patient are an integral component of treatment. The present study compares two methods of immobilization with no immobilization with an aim of identifying the most reproducible method. Materials and methods 65 consecutive patients receiving pelvic external beam radiotherapy were retrospectively analyzed. 30, 21 and 14 patients were treated with no-immobilization with a leg separator, whole body vacuum bag cushion (VBC) and six point aquaplast immobilization system, respectively. The systematic error, random error and the planning target volume (PTV) margins were calculated for all the three techniques and statistically analyzed. Results The systematic errors were the highest in the VBC and random errors were the highest in the aquaplast group. Both systematic and random errors were the lowest in patients treated with no-immobilization. 3D Systematic error (mm, mean ± 1SD) was 4.31 ± 3.84, 3.39 ± 1.71 and 2.42 ± 0.97 for VBC, aquaplast and no-immobilization, respectively. 3D random error (mm, 1SD) was 2.96, 3.59 and 1.39 for VBC, aquaplast and no-immobilization, respectively. The differences were statistically significant between all the three groups. The calculated PTV margins were the smallest for the no-immobilization technique with 4.56, 4.69 and 4.59 mm, respectively, in x, y and z axes, respectively. Conclusions Among the three techniques, no-immobilization technique with leg separator was the most reproducible technique with the smallest PTV margins. For obvious reasons, this technique is the least time consuming and most economically viable in developing countries.
Collapse
Affiliation(s)
- Avinash H Udayashankar
- Department of Radiation Oncology, St John's Medical College Hospital, St John's National Academy of Health Sciences, Sarjapur Road, Bangalore 560034, India
| | - Shibina Noorjahan
- Department of Radiation Oncology, St John's Medical College Hospital, St John's National Academy of Health Sciences, Sarjapur Road, Bangalore 560034, India
| | - Nirmala Srikantia
- Department of Radiation Oncology, St John's Medical College Hospital, St John's National Academy of Health Sciences, Sarjapur Road, Bangalore 560034, India
| | - K Ravindra Babu
- Department of Radiation Oncology, St John's Medical College Hospital, St John's National Academy of Health Sciences, Sarjapur Road, Bangalore 560034, India
| | - Sandeep Muzumder
- Department of Radiation Oncology, St John's Medical College Hospital, St John's National Academy of Health Sciences, Sarjapur Road, Bangalore 560034, India
| |
Collapse
|
9
|
Wang G, Wang WL, Liu YQ, Dong HM, Hu YX. Positioning error and expanding margins of planning target volume with kilovoltage cone beam computed tomography for prostate cancer radiotherapy. Onco Targets Ther 2018; 11:1981-1988. [PMID: 29670373 PMCID: PMC5898597 DOI: 10.2147/ott.s152915] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Objective In this study, prostate cancer patients were treated with image-guided radiotherapy (IGRT). The translational positioning errors were discussed to provide the basis for determining margins of the planning target volume (PTV). Methods Thirty prostate cancer patients were treated with radical radiotherapy using the IGRT system. Patients were placed in the supine position and underwent kilovoltage cone beam computed tomography (KVCBCT) scans before radiotherapy. A total of 447 images were acquired. The translational positioning errors were obtained in three linear directions which were X (left-to-right), Y (superior-to-inferior) and Z (anterior-to-posterior) axes (denoted as Lx, Ly and Lz) through the contrast between images adjusted with gray and manual registrations and the planning CT images. Rotational errors were denoted as Rx, Ry and Rz. Results Uncorrected translational errors Lx, Ly and Lz in the 251 positioning images were all higher than those after correction, and the differences were all statistically significant (P=0.000, 0.037 and 0.004, respectively). For rotational errors Rx, Ry and Rz, only Rx had a significant difference before and after correction (P=0.044). Before correction, PTV margins in the X, Y and Z directions were 0.61, 0.78 and 0.41 cm, respectively; after correction, these were 0.17, 0.12 and 0.17 cm, respectively. Conclusion KVCBCT can be applied to measure positioning errors in prostate cancer radiotherapy and correct these errors in real time through the 6° robotic patient positioning system, in order to improve patient positioning accuracy. The application of IGRT with KVCBCT may reduce PTV margins.
Collapse
Affiliation(s)
- Gang Wang
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Wen-Ling Wang
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Yi-Qun Liu
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Hong-Min Dong
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Yin-Xiang Hu
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| |
Collapse
|
10
|
Olausson K, Holst Hansson A, Zackrisson B, Edvardsson D, Östlund U, Nyholm T. Development and psychometric testing of an instrument to measure the patient's experience of external radiotherapy: The Radiotherapy Experience Questionnaire (RTEQ). Tech Innov Patient Support Radiat Oncol 2017; 3-4:7-12. [PMID: 32095560 PMCID: PMC7033812 DOI: 10.1016/j.tipsro.2017.06.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 02/14/2017] [Accepted: 06/29/2017] [Indexed: 12/03/2022] Open
Abstract
A new instrument to measure the patient’s comfort and experiences during RT. The instrument gains the patients’ perspectives of the RT procedures. RTEQ has a possible application for evaluation of newly introduced techniques.
Background The patient’s perception of external radiotherapy (RT) procedures and equipment is important to evaluate as a complement to endpoints such as treatment outcome and reproducibility. There is a lack of a proper, psychometrically robust instrument to evaluate the patient’s comfort and experience of the external RT procedure. Hence, this study aimed to develop and test an instrument to measure the patient’s experience during external RT. Material and Methods A preliminary 34-item questionnaire was generated from research literature, expert consultations and patient interviews, and it was distributed to patients (n = 825) at 8 RT units in Sweden. The answers were subjected to item analysis and reduction by using exploratory factor analysis. The reliability of the final questionnaire was evaluated using Cronbach’s alpha. Mean scale scores were compared across gender, length of RT and treatment area. Results Most items were highly skewed towards positive responses. Scree plot analyses of the 34-item correlation matrix identified six underlying themes explaining 68% of the total variance. After item reduction, the 6 themes explained 73% of the variance in a 23-item questionnaire. Cronbach’s alpha was satisfactory for all themes (between 0.79 and 0.9). Significant differences between treatment areas were found for two scales: situational unease and situational repose. Conclusion The RT Experience Questionnaire is a tentatively valid and reliable instrument to measure how patients experience the external RT session process and the environment in the treatment room.
Collapse
Affiliation(s)
- Kristina Olausson
- Umeå University, Department of Radiation Sciences, Umeå, Sweden
- Corresponding author at: Department of Radiation Sciences, Umeå University Hospital, SE 901 87 Umeå, Sweden.
| | - Annette Holst Hansson
- Department of Care Sciences, Faculty of Health and Society, Malmö, Sweden
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
| | | | - David Edvardsson
- La Trobe University/Austin Health Clinical School of Nursing, Melbourne, Australia
- Umeå University, Department of Nursing, Umeå, Sweden
| | - Ulrika Östlund
- Centre for Research & Development, Uppsala University/Region Gävleborg, Sweden
- Centre for Collaborative Palliative Care, Linnaeus University, Kalmar, Sweden
| | - Tufve Nyholm
- Umeå University, Department of Radiation Sciences, Umeå, Sweden
- Department of Immunology, Genetics and Pathology, Medical Radiation Science, Uppsala University, Uppsala, Sweden
| |
Collapse
|
11
|
Pang EPP, Knight K, Baird M, Loh JMQ, Boo AHS, Tuan JKL. A comparison of interfraction setup error, patient comfort, and therapist acceptance for 2 different prostate radiation therapy immobilization devices. Adv Radiat Oncol 2017; 2:125-131. [PMID: 28740923 PMCID: PMC5514259 DOI: 10.1016/j.adro.2017.02.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 12/12/2016] [Accepted: 02/08/2017] [Indexed: 11/18/2022] Open
Abstract
PURPOSE Our purpose was to investigate interfraction setup error of the immobilization device required to implement transperineal ultrasound compared with the current, standard immobilization device. Patient comfort and radiation therapist (RT) satisfaction were also assessed. METHODS AND MATERIALS Cone beam computed tomography images were acquired before 4069 fractions from 111 patients (control group, n = 56; intervention group, n = 55) were analyzed. The intervention group was immobilized using the Clarity Immobilization System (CIS), comprising a knee rest with autoscan probe kit and transperineal ultrasound probe (n = 55), and control group using a leg immobilizer (LI) (n = 56). Interfraction setup errors were compared for both groups. Weekly questionnaires using a 10-point visual analog scale were administered to both patient groups to measure and compare patient comfort. RT acceptance for both devices was also compared using a survey. RESULTS There was no significant difference in the magnitude of interfraction cone beam computed tomography-derived setup shifts in the lateral and anteroposterior direction between the LI and CIS (P = .878 and .690, respectively). However, a significant difference (P = .003) was observed in the superoinferior direction between the 2 groups of patients. Patient-reported level of comfort and stability demonstrated no significant difference between groups (P = .994 and .132). RT user acceptance measures for the LI and CIS were ease of handling (100% vs 53.7%), storage (100% vs 61.1%), and cleaning of the devices (100% vs 64.8%), respectively. CONCLUSIONS The CIS demonstrated stability and reproducibility in prostate treatment setup comparable to LI. The CIS device had no impact on patient comfort; however, RTs indicated a preference for LI over the CIS mainly because of its weight and bulkiness.
Collapse
Affiliation(s)
- Eric Pei Ping Pang
- Faculty of Medicine, Nursing and Health Sciences, Department of Medical Imaging and Radiation Sciences, Monash University, Wellington Road, Clayton, Victoria, Australia
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
- Corresponding author. Division of Radiation Oncology, National Cancer Centre Singapore, 11 Hospital Drive, Singapore.Division of Radiation OncologyNational Cancer Centre Singapore11 Hospital DriveSingapore
| | - Kellie Knight
- Faculty of Medicine, Nursing and Health Sciences, Department of Medical Imaging and Radiation Sciences, Monash University, Wellington Road, Clayton, Victoria, Australia
| | - Marilyn Baird
- Faculty of Medicine, Nursing and Health Sciences, Department of Medical Imaging and Radiation Sciences, Monash University, Wellington Road, Clayton, Victoria, Australia
| | | | | | - Jeffrey Kit Loong Tuan
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
- Duke-National University of Singapore Graduate Medical School, Singapore
| |
Collapse
|
12
|
Lin CG, Xu SK, Yao WY, Wu YQ, Fang JL, Wu VWC. Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients. J Med Radiat Sci 2016; 64:106-113. [PMID: 27741377 PMCID: PMC5454330 DOI: 10.1002/jmrs.189] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 07/20/2016] [Accepted: 07/22/2016] [Indexed: 12/25/2022] Open
Abstract
Introduction In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. Methods Patients were randomly assigned to one of the three immobilisation systems: (1) supine on head rest and base plate (HB); (2) supine with alpha cradle supporting the head and shoulder (AC); (3) supine with vacuum bag supporting the head and shoulder (VB). CBCT was conducted weekly for each patient on the linear accelerator. Image registration was conducted at the nasopharynx (NP) and cervical regions. The translational displacements (latero‐medial, antero‐posterior and cranio‐caudal), rotational displacements (pitch, yaw and roll) and 3D vectors obtained at the NP and cervical regions were recorded and compared among the three systems. Results The mean translational and rotational deviations were within 3 mm and 2°, respectively, and the range of 3D vector was 1.53–3.47 mm. At the NP region, the AC system demonstrated the smallest translational and rotational deviations and 3D vector. The differences were significant except for the latero‐medial, yaw and roll directions. Similarly, at the cervical region, the AC system showed smaller translational and rotational deviations and 3D vector, with only the cranio‐caudal and yaw deviations that did not reach statistical significance. Conclusions Set up deviation was greater in the neck than the NP region. The set up accuracy of the AC system was better than the other two systems, and it is recommended for IMRT of NPC patients in our institution.
Collapse
Affiliation(s)
- Cheng-Guang Lin
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Sen-Kui Xu
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Wen-Yan Yao
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Yu-Qi Wu
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Jian-Lan Fang
- State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Vincent W C Wu
- Department of Health Technology and Informatics, Hong Kong Polytechnic University, Hung Hom, Hong Kong
| |
Collapse
|
13
|
Abstract
We reviewed the literature on the use of margins in radiotherapy of patients with prostate cancer, focusing on different options for image guidance (IG) and technical issues. The search in PubMed database was limited to include studies that involved external beam radiotherapy of the intact prostate. Post-prostatectomy studies, brachytherapy and particle therapy were excluded. Each article was characterized according to the IG strategy used: positioning on external marks using room lasers, bone anatomy and soft tissue match, usage of fiducial markers, electromagnetic tracking and adapted delivery. A lack of uniformity in margin selection among institutions was evident from the review. In general, introduction of pre- and in-treatment IG was associated with smaller planning target volume (PTV) margins, but there was a lack of definitive experimental/clinical studies providing robust information on selection of exact PTV values. In addition, there is a lack of comparative research regarding the cost-benefit ratio of the different strategies: insertion of fiducial markers or electromagnetic transponders facilitates prostate gland localization but at a price of invasive procedure; frequent pre-treatment imaging increases patient in-room time, dose and labour; online plan adaptation should improve radiation delivery accuracy but requires fast and precise computation. Finally, optimal protocols for quality assurance procedures need to be established.
Collapse
Affiliation(s)
- Slav Yartsev
- 1 London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada.,2 Departments of Oncology and Medical Biophysics, Western University, London, ON, Canada
| | - Glenn Bauman
- 1 London Regional Cancer Program, London Health Sciences Centre, London, ON, Canada.,2 Departments of Oncology and Medical Biophysics, Western University, London, ON, Canada
| |
Collapse
|
14
|
Law G, Leung R, Lee F, Luk H, Lee KC, Wong F, Wong M, Cheung S, Lee V, Mui WH, Chan M. Effectiveness of a Patient-Specific Immobilization and Positioning System to Limit Interfractional Translation and Rotation Setup Errors in Radiotherapy of Prostate Cancers. ACTA ACUST UNITED AC 2016. [DOI: 10.4236/ijmpcero.2016.53020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
15
|
Eom KY, Chie EK, Kim K, Chang JH, Koo TR, Park JI, Park YG, Ye SJ, Ha SW. Pilot study on interfractional and intrafractional movements using surface infrared markers and EPID for patients with rectal cancer treated in the prone position. Br J Radiol 2015; 88:20150144. [PMID: 25996578 DOI: 10.1259/bjr.20150144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To evaluate interfractional and intrafractional movement of patients with rectal cancer during radiotherapy with electronic portal imaging device (EPID) and surface infrared (IR) markers. METHODS 20 patients undergoing radiotherapy for rectal cancer with body mass index ranging from 18.5 to 30 were enrolled. Patients were placed in the prone position on a couch with a leg pillow. Three IR markers were put on the surface of each patient and traced by two stereo cameras during radiotherapy on a twice-weekly basis. Interfractional isocentre movement was obtained with EPID images on a weekly basis. Movement of the IR markers was analysed in correlation with the isocentre movement obtained from the EPID images. RESULTS The maximum right-to-left (R-L) movement of the laterally located markers in the horizontal isocentre plane was correlated with isocentre translocation with statistical significance (p = 0.018 and 0.015, respectively). Movement of the surface markers was cyclical. For centrally located markers, the 95% confidence intervals for the average amplitude in the R-L, cranial-to-caudal (C-C) and anterior-to-posterior (A-P) directions were 0.86, 2.25 and 3.48 mm, respectively. In 10 patients, intrafractional movement exceeding 5 mm in at least one direction was observed. Time-dependent systematic movement of surface markers during treatment, which consisted of continuous movement towards the cranial direction and a sail back motion in the A-P direction, was also observed. CONCLUSION Intrafractional movement of surface markers has both cyclic components and time-dependent systematic components. Marker deviations exceeding 5 mm were mainly seen in the A-P direction. Pre- or post-treatment EPID images may not provide adequate information regarding intrafractional movement because of systematic movement in the A-P direction during radiotherapy. ADVANCES IN KNOWLEDGE This work uncovered a sail back motion of patients in the A-P direction during radiotherapy. Pre- or post-treatment EPID images may not provide accurate positioning of patients in the A-P direction because of this time-dependent intrafractional motion.
Collapse
Affiliation(s)
- K-Y Eom
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - E K Chie
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea.,2 Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul, Republic of Korea
| | - K Kim
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - J H Chang
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - T R Koo
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - J I Park
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Y-G Park
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - S-J Ye
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea.,3 Department of Transdisciplinary Studies and Advanced Institute of Convergence Technology, Graduate School of Convergence Science and Technology, Seoul National University, Suwon, Republic of Korea
| | - S W Ha
- 1 Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea.,2 Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
16
|
Clemente S, Nigro R, Oliviero C, Marchioni C, Esposito M, Giglioli FR, Mancosu P, Marino C, Russo S, Stasi M, Strigari L, Veronese I, Landoni V. Role of the Technical Aspects of Hypofractionated Radiation Therapy Treatment of Prostate Cancer: A Review. Int J Radiat Oncol Biol Phys 2015; 91:182-95. [DOI: 10.1016/j.ijrobp.2014.08.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2014] [Revised: 08/01/2014] [Accepted: 08/04/2014] [Indexed: 10/24/2022]
|
17
|
Image guidance procedures in radiotherapy for prostate cancer and the influence of body mass index. JOURNAL OF RADIOTHERAPY IN PRACTICE 2014. [DOI: 10.1017/s1460396914000193] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
AbstractPurposeTo investigate possible optimisation of the image guidance procedure for the prostate cancer patients with respect to imaging frequency and patient body mass index (BMI).MethodsThe 6,085 setup correction shifts and BMI for 216 prostate cancer patients treated on tomotherapy units in two centres were analysed. Margins needed to account for inter-fraction target motion with daily only automatic correction and with automatic and manual corrections during one, three or five first fractions as a reference for further treatment without imaging were calculated.ResultsThe planning target volume margin calculated for the daily automatic correction only scheme was significantly lower than the margins calculated for the image guidance limited to a few initial fractions. Manual corrections after automatic fusion were more important for patients with higher BMI. On average, the patients with normal BMI had manual correction shift of 0·7 mm in anterioposterior direction, while overweight and obese patients required, correspondingly, the shifts of 1·3 and 1·4 mm.ConclusionOverweight and obese patients require daily imaging with time saving available by performing automatic kV/MV computed tomography registration only. The patients with normal BMI may be treated with imaging guidance during a few initial treatment fractions.
Collapse
|