1
|
Manser P, de Bruin ED. Diagnostic accuracy, reliability, and construct validity of the German quick mild cognitive impairment screen. BMC Geriatr 2024; 24:613. [PMID: 39026157 PMCID: PMC11256646 DOI: 10.1186/s12877-024-05219-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 07/12/2024] [Indexed: 07/20/2024] Open
Abstract
BACKGROUND Early detection of cognitive impairment is among the top research priorities aimed at reducing the global burden of dementia. Currently used screening tools have high sensitivity but lack specificity at their original cut-off, while decreasing the cut-off was repeatedly shown to improve specificity, but at the cost of lower sensitivity. In 2012, a new screening tool was introduced that aims to overcome these limitations - the Quick mild cognitive impairment screen (Qmci). The original English Qmci has been rigorously validated and demonstrated high diagnostic accuracy with both good sensitivity and specificity. We aimed to determine the optimal cut-off value for the German Qmci, and evaluate its diagnostic accuracy, reliability (internal consistency) and construct validity. METHODS We retrospectively analyzed data from healthy older adults (HOA; n = 43) and individuals who have a clinical diagnosis of 'mild neurocognitive disorder' (mNCD; n = 37) with a biomarker supported characterization of the etiology of mNCD of three studies of the 'Brain-IT' project. Using Youden's Index, we calculated the optimal cut-off score to distinguish between HOA and mNCD. Receiver operating characteristic (ROC) curve analysis was performed to evaluate diagnostic accuracy based on the area under the curve (AUC). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Reliability (internal consistency) was analyzed by calculating Cronbach's α. Construct validity was assessed by analyzing convergent validity between Qmci-G subdomain scores and reference assessments measuring the same neurocognitive domain. RESULTS The optimal cut-off score for the Qmci-G was ≤ 67 (AUC = 0.96). This provided a sensitivity of 91.9% and a specificity of 90.7%. The PPV and NPV were 89.5% and 92.9%, respectively. Cronbach's α of the Qmci-G was 0.71 (CI95% [0.65 to 0.78]). The Qmci-G demonstrated good construct validity for subtests measuring learning and memory. Subtests that measure executive functioning and/or visuo-spatial skills showed mixed findings and/or did not correlate as strongly as expected with reference assessments. CONCLUSION Our findings corroborate the existing evidence of the Qmci's good diagnostic accuracy, reliability, and construct validity. Additionally, the Qmci shows potential in resolving the limitations of commonly used screening tools, such as the Montreal Cognitive Assessment. To verify these findings for the Qmci-G, testing in clinical environments and/or primary health care and direct comparisons with standard screening tools utilized in these settings are warranted.
Collapse
Affiliation(s)
- Patrick Manser
- Motor Control and Learning Group - Institute of Human Movement Sciences and Sport, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
| | - Eling D de Bruin
- Motor Control and Learning Group - Institute of Human Movement Sciences and Sport, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
- Department of Health, OST - Eastern Swiss University of Applied Sciences, St. Gallen, Switzerland
- Division of Physiotherapy, Department of Neurobiology, Care Sciences and Society, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
2
|
Dros C, Sealy MJ, Krijnen WP, Weening-Verbree LF, Hobbelen H, Jager-Wittenaar H. Oral Health and Frailty in Community-Dwelling Older Adults in the Northern Netherlands: A Cross-Sectional Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:7654. [PMID: 35805314 PMCID: PMC9265776 DOI: 10.3390/ijerph19137654] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 06/18/2022] [Accepted: 06/21/2022] [Indexed: 12/04/2022]
Abstract
The aim of this study was to explore the association between oral health and frailty in community-dwelling Dutch adults aged 55 years and older. Included were 170 participants (n = 95 female [56%]; median age 64 years [IQR: 59−69 years]). Frailty was assessed by the Groningen Frailty Indicator. Oral health was assessed by the Oral Health Impact Profile-14-NL (OHIP-NL14). OHIP-NL14 item scores were analyzed for differences between frail and non-frail participants. Univariate and multivariate logistic regression analyses were performed to assess the association between oral health and presence of frailty. The multivariate analysis included age, gender, and depressive symptoms as co-variables. After adjustment, 1 point increase on the OHIP-NL14 scale was associated with 21% higher odds of being frail (p = 0.000). In addition, significantly more frail participants reported presence of problems on each OHIP-NL14 item, compared to non-frail participants (p < 0.003). Contrast in prevalence of different oral health problems between frail and non-frail was most prominent in ‘younger’ older adults aged 55−64 years. In conclusion: decreased oral health was associated with frailty in older adults aged ≥55 years. Since oral health problems are not included in most frailty assessments, tackling oral health problems may not be sufficiently emphasized in frailty policies.
Collapse
Affiliation(s)
- Coen Dros
- Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands; (C.D.); (W.P.K.); (L.F.W.-V.); (H.H.); (H.J.-W.)
| | - Martine J. Sealy
- Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands; (C.D.); (W.P.K.); (L.F.W.-V.); (H.H.); (H.J.-W.)
- FAITH Research, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands
| | - Wim P. Krijnen
- Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands; (C.D.); (W.P.K.); (L.F.W.-V.); (H.H.); (H.J.-W.)
- FAITH Research, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands
- Johan Bernoulli Institute for Mathematics and Computer Science, University of Groningen, 9700 AK Groningen, The Netherlands
| | - Lina F. Weening-Verbree
- Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands; (C.D.); (W.P.K.); (L.F.W.-V.); (H.H.); (H.J.-W.)
- Center for Dentistry and Oral Hygiene, University Medical Center Groningen, Antonius Deusinglaan 1, FB 21, 9713 AV Groningen, The Netherlands
| | - Hans Hobbelen
- Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands; (C.D.); (W.P.K.); (L.F.W.-V.); (H.H.); (H.J.-W.)
- FAITH Research, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands
- Department of General Practice and Elderly Care Medicine, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
| | - Harriët Jager-Wittenaar
- Research Group Healthy Ageing, Allied Health Care and Nursing, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands; (C.D.); (W.P.K.); (L.F.W.-V.); (H.H.); (H.J.-W.)
- FAITH Research, Petrus Driessenstraat 3, 9714 CA Groningen, The Netherlands
- Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
| |
Collapse
|
3
|
te Pas M, Olde Rikkert M, Bouwman A, Kessels R, Buise M. Screening for Mild Cognitive Impairment in the Preoperative Setting: A Narrative Review. Healthcare (Basel) 2022; 10:1112. [PMID: 35742163 PMCID: PMC9223065 DOI: 10.3390/healthcare10061112] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 05/26/2022] [Accepted: 06/13/2022] [Indexed: 11/28/2022] Open
Abstract
Cognitive impairment predisposes patients to the development of delirium and postoperative cognitive dysfunction. In particular, in older patients, the adverse sequelae of cognitive decline in the perioperative period may contribute to adverse outcomes after surgical procedures. Subtle signs of cognitive impairment are often not previously diagnosed. Therefore, the aim of this review is to describe the available cognitive screeners suitable for preoperative screening and their psychometric properties for identifying mild cognitive impairment, as preoperative workup may improve perioperative care for patients at risk for postoperative cognitive dysfunction. Electronic systematic and snowball searches of PubMed, PsycInfo, ClinicalKey, and ScienceDirect were conducted for the period 2015-2020. Major inclusion criteria for articles included those that discussed a screener that included the cognitive domain 'memory', that had a duration time of less than 15 min, and that reported sensitivity and specificity to detect mild cognitive impairment. Studies about informant-based screeners were excluded. We provided an overview of the characteristics of the cognitive screener, such as interrater and test-retest reliability correlations, sensitivity and specificity for mild cognitive impairment and cognitive impairment, and duration of the screener and cutoff points. Of the 4775 identified titles, 3222 were excluded from further analysis because they were published prior to 2015. One thousand four hundred and forty-eight titles did not fulfill the inclusion criteria. All abstracts of 52 studies on 45 screeners were examined of which 10 met the inclusion criteria. For these 10 screeners, a further snowball search was performed to obtain related studies, resulting in 20 articles. Screeners included in this review were the Mini-Cog, MoCA, O3DY, AD8, SAGE, SLUMS, TICS(-M), QMCI, MMSE2, and Mini-ACE. The sensitivity and specificity range to detect MCI in an older population is the highest for the MoCA, with a sensitivity range of 81-93% and a specificity range of 74-89%. The MoCA, with the highest combination of sensitivity and specificity, is a feasible and valid routine screening of pre-surgical cognitive function. This warrants further implementation and validation studies in surgical pathways with a large proportion of older patients.
Collapse
Affiliation(s)
- Mariska te Pas
- Department of Anesthesiology, Catharina Hospital, 5623 EJ Eindhoven, The Netherlands; (A.B.); (M.B.)
| | - Marcel Olde Rikkert
- Radboud University Medical Center, Department of Geriatric Medicine, 6500 GL Nijmegen, The Netherlands;
| | - Arthur Bouwman
- Department of Anesthesiology, Catharina Hospital, 5623 EJ Eindhoven, The Netherlands; (A.B.); (M.B.)
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| | - Roy Kessels
- Donders Institute for Brain, Cognition and Behaviour, Radboud University, 6525 XZ Nijmegen, The Netherlands;
- Department of Medical Psychology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
- Vincent van Gogh Institute for Psychiatry, 5803 AC Venray, The Netherlands
| | - Marc Buise
- Department of Anesthesiology, Catharina Hospital, 5623 EJ Eindhoven, The Netherlands; (A.B.); (M.B.)
| |
Collapse
|
4
|
Comparison of the Greek Version of the Quick Mild Cognitive Impairment Screen and Montreal Cognitive Assessment in Older Adults. Healthcare (Basel) 2022; 10:healthcare10050906. [PMID: 35628043 PMCID: PMC9141789 DOI: 10.3390/healthcare10050906] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 05/01/2022] [Accepted: 05/06/2022] [Indexed: 02/04/2023] Open
Abstract
Objective: Cognitive screening instruments (CSIs) are essential for everyday practice. The Quick Mild Cognitive Impairment (Qmci) screen, a short instrument designed to identify mild cognitive impairment, was recently translated into Greek (Qmci-Gr). The present study compared its diagnostic value against the Montreal Cognitive Assessment (MoCA) screen and examined its optimal cutoffs. Method: We recruited consecutive patients aged ≥55 years that presented with cognitive complaints from two outpatient clinics in Greece. The Qmci-Gr and MoCA were completed by all patients. Furthermore, they were assessed independently with a comprehensive flexible neuropsychological battery to establish a diagnostic classification. Results: In the current study, we assessed a total of 145 patients, with a median age of 70 years; 44 were classified as having Subjective Memory Complaints (SMC) but normal cognition, 32 with MCI and 69 with dementia. The Qmci-Gr had a higher accuracy compared to the MoCA in discriminating MCI from dementia, area under the curve (AUC) of 0.81 versus 0.75, respectively; however, this finding was marginally significant (p = 0.08). Its accuracy was marginally higher for distinguishing SMC from dementia, AUC of 0.94 versus 0.89 (p = 0.03). However, Qmci-Gr presented a lower accuracy than MoCa in differentiating SMC from MCI, AUC of 0.76 versus 0.94 (p = 0.006). Conclusions: The Qmci-Gr has comparable diagnostic accuracy to the MoCA regarding MCI and dementia groups. Further research, with larger and more diverse samples, may be necessary to ensure generalizability.
Collapse
|
5
|
Lee CT, Chan KC, Tsuang FY, Lin CP, Wu CY. Changes in the quick mild cognitive impairment test over time: A normative study in an adult sample in Taiwan. J Formos Med Assoc 2021; 121:1392-1396. [PMID: 34656404 DOI: 10.1016/j.jfma.2021.09.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 07/29/2021] [Accepted: 09/28/2021] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND The Quick Mild Cognitive Impairment (Qmci) test has been suggested to be an easy-to-use and precise screening tool for detecting postoperative cognitive dysfunction (POCD). To provide essential information for future POCD studies in Taiwan, the present study provided data regarding the Taiwan version of the Qmci (Qmci-TW) test conducted in the normative Taiwanese population and changes in them over time. METHODS The present study recruited adult native Taiwanese volunteers without known neurologic or psychiatric diseases. All enrolled participants received protocolized serial Qmci-TW test at baseline, 2-day follow-up, and 6-month follow-up. RESULTS In total, 30 participants, 15 men and 15 women, were enrolled in this study. The baseline Qmci-TW score ranged from 55 to 80, with a mean of 68.9 and a standard deviation (SD) of 7. At 2-day follow-up, the mean Qmci-TW test score was significantly higher (by 5.3; SD = 7.3) than that at baseline (P = 0.001). At 6-month follow-up, the mean Qmci-TW score was 71.3 (SD = 6.1), with no significant difference compared with that at baseline. The decline in Qmci-TW scores by > 9 points on postoperative day 1 and by > 11 points at 6-month follow-up was the criterion for POCD. CONCLUSION The present study provided data regarding the Qmci-TW test conducted in the normative Taiwanese population and its time trajectory during the 6-month follow-up.
Collapse
Affiliation(s)
- Chen-Tse Lee
- Department of Anesthesiology, National Taiwan University Hospital, Taipei, Taiwan
| | - Kuang-Cheng Chan
- Department of Anesthesiology, National Taiwan University Hospital, Taipei, Taiwan
| | - Fon-Yih Tsuang
- Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan
| | - Chih-Peng Lin
- Department of Anesthesiology, National Taiwan University Hospital, Taipei, Taiwan
| | - Chun-Yu Wu
- Department of Anesthesiology, National Taiwan University Hospital, Taipei, Taiwan.
| |
Collapse
|
6
|
Rezaei M, Shariati B, Molloy DW, O’Caoimh R, Rashedi V. The Persian Version of the Quick Mild Cognitive Impairment Screen (Q mci-Pr): Psychometric Properties among Middle-Aged and Older Iranian Adults. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:8582. [PMID: 34444331 PMCID: PMC8393250 DOI: 10.3390/ijerph18168582] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 08/03/2021] [Accepted: 08/11/2021] [Indexed: 01/15/2023]
Abstract
Brief cognitive screening instruments are used to identify patients presenting with cognitive symptoms that warrant further assessment. This study aimed to evaluate the reliability and validity of the Persian version of the Quick Mild Cognitive Impairment (Qmci-Pr) among middle-aged and older Iranian adults. Consecutive patients aged ≥55 years and caregivers attending with them as normal controls (NCs) were recruited from geriatric outpatient clinics and a hospital in Tehran, Iran. All patients completed the Qmci-Pr before completing an independent detailed neuropsychological assessment and staging using the Clinical Dementia Rating (CDR) Scale. NCs underwent the same assessment. In all, 92 participants with a median age of 70 years (±13) were available. Of these, 20 participants were NCs, 24 had subjective memory complaints (SMC), 24 had mild cognitive impairment (MCI), and 24 had Alzheimer's disease (AD). The Qmci-Pr had good accuracy in differentiating SMC and NC from MCI (area under the curve (AUC): 0.80 (0.69-0.91)) and in identifying cognitive impairment (MCI and mild AD) (AUC: 0.87 (0.80-0.95)) with a sensitivity of 88% and specificity of 80%, at an optimal cut-off of <53/100. The Qmci-Pr is an accurate short cognitive screening impairment for separating NC and patients with SMC from MCI and identifying cognitive impairment. Further research with larger samples and comparison with other widely used instruments such as the Montreal Cognitive Assessment is needed. Given its established brevity, the Qmci-Pr is a useful screen for Iranian adults across the spectrum of cognitive decline.
Collapse
Affiliation(s)
- Mohammad Rezaei
- Autism Spectrum Disorders Research Center, Hamadan University of Medical Sciences, Hamadan 6517838687, Iran;
| | - Behnam Shariati
- Mental Health Research Center, Department of Psychiatry, School of Medicine, Iran University of Medical Sciences, Tehran 1449614535, Iran;
| | - David William Molloy
- Department of Geriatric Medicine, Mercy University Hospital, T12 WE28 Cork, Ireland; (D.W.M.); (R.O.)
| | - Rónán O’Caoimh
- Department of Geriatric Medicine, Mercy University Hospital, T12 WE28 Cork, Ireland; (D.W.M.); (R.O.)
| | - Vahid Rashedi
- School of Behavioral Sciences and Mental Health (Tehran Institute of Psychiatry), Iran University of Medical Sciences, Tehran 1445613111, Iran
| |
Collapse
|
7
|
Messinis L, O'Donovan MR, Molloy DW, Mougias A, Nasios G, Papathanasopoulos P, Ntoskou A, O'Caoimh R. Comparison of the Greek Version of the Quick Mild Cognitive Impairment Screen and Standardised Mini-Mental State Examination. Arch Clin Neuropsychol 2021; 36:578-586. [PMID: 32783063 DOI: 10.1093/arclin/acaa062] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/27/2020] [Accepted: 07/16/2020] [Indexed: 12/19/2022] Open
Abstract
INTRODUCTION Short cognitive screening instruments (CSIs) are widely used to stratify patients presenting with cognitive symptoms. The Quick Mild Cognitive Impairment (Qmci) screen is a new, brief (<5mins) CSI designed to identify mild cognitive impairment (MCI), which can be used across the spectrum of cognitive decline. Here we present the translation of the Qmci into Greek (Qmci-Gr) and its validation against the widely-used Standardised Mini-Mental State Examination (SMMSE). METHODS Consecutive patients aged ≥55 years presenting with cognitive complaints were recruited from two outpatient clinics in Greece. All patients completed the Qmci-Gr and SMMSE and underwent an independent detailed neuropsychological assessment to determine a diagnostic classification. RESULTS In total, 140 patients, median age 75 years, were included; 30 with mild dementia (median SMMSE 23/30), 76 with MCI and 34 with subjective memory complaints (SMC) but normal cognition. The Qmci-Gr had similar accuracy in differentiating SMC from cognitive impairment (MCI & mild dementia) compared with SMMSE, area under the curve (AUC) of 0.84 versus 0.79, respectively; while accuracy was higher for the Qmci-Gr, this finding was not significantly different, (p = .19). Similarly, the Qmci-Gr had similar accuracy in separating SMC from MCI, AUC of 0.79 versus 0.73 (p = .23). CONCLUSIONS The Qmci-Gr compared favorably with the SMMSE. Further research with larger samples and comparison with other instruments such as the Montreal Cognitive Assessment is needed to confirm these findings but given its established brevity, it may be a better choice in busy clinical practice in Greece.
Collapse
Affiliation(s)
- Lambros Messinis
- Neuropsychology Section, Departments of Neurology and Psychiatry, University Hospital of Patras and University of Patras Medical School, Patras, Greece
| | - Mark R O'Donovan
- Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland.,Health Research Board, Clinical Research Facility Cork, University College Cork, Mercy University Hospital, Grenville Place, Cork, Ireland
| | - D William Molloy
- Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland
| | - Antonis Mougias
- Alzheimer Center, Greek Psychogeriatric Association "Nestor", Athens, Greece
| | - Grigorios Nasios
- Department of Speech and Language Therapy, School of Health Sciences, University of Ioannina, Ioannina, Greece
| | | | - Aikaterini Ntoskou
- Rehabilitation Unit for patients with Spinal Cord Injury, "Demetrios and Vera Sfikas" Department of Medicine, University of Patras Medical School, Patras, Greece
| | - Rónán O'Caoimh
- Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland
| |
Collapse
|
8
|
Xu Y, Yi L, Lin Y, Peng S, Wang W, Lin W, Chen P, Zhang W, Deng Y, Guo S, Shi L, Wang Y, Molloy DW, O'Caoimh R. Screening for Cognitive Impairment After Stroke: Validation of the Chinese Version of the Quick Mild Cognitive Impairment Screen. Front Neurol 2021; 12:608188. [PMID: 33763012 PMCID: PMC7982853 DOI: 10.3389/fneur.2021.608188] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 02/11/2021] [Indexed: 12/11/2022] Open
Abstract
Background: Screening for post-stroke cognitive impairment (PSCI) is necessary because stroke increases the incidence of and accelerates premorbid cognitive decline. The Quick Mild Cognitive Impairment (Qmci) screen is a short, reliable and accurate cognitive screening instrument but is not yet validated in PSCI. We compared the diagnostic accuracy of a Chinese version of the Qmci screen (Qmci-CN) compared with the widely-used Chinese versions of the Montreal Cognitive Assessment (MoCA-CN) and Mini-Mental State Examination (MMSE-CN). Methods: We recruited 34 patients who had recovered from a stroke in rehabilitation unit clinics in 2 university hospitals in China: 11 with post-stroke dementia (PSD), 15 with post-stroke cognitive impairment no dementia (PSCIND), and 8 with normal cognition (NC). Classification was made based on clinician assessment supported by a neuropsychological battery, independent of the screening test scores. The Qmci-CN, MoCA-CN, and MMSE-CN screens were administered randomly by a trained rater, blind to the diagnosis. Results: The mean age of the sample was 63 ± 13 years and 61.8% were male. The Qmci-CN had statistically similar diagnostic accuracy in differentiating PSD from NC, an area under the curve (AUC) of 0.94 compared to 0.99 for the MoCA-CN (p = 0.237) and 0.99 for the MMSE-CN (p = 0.293). The Qmci-CN (AUC 0.91), MoCA-CN (AUC 0.94), and MMSE-CN (AUC 0.79) also had statistically similar accuracy in separating PSD from PSCIND. The MoCA-CN more accurately distinguished between PSCIND and normal cognition than the Qmci-CN (p = 0.015). Compared to the MoCA-CN, the administration times of the Qmci-CN (329s vs. 611s, respectively, p < 0.0001) and MMSE-CN (280 vs. 611s, respectively, p < 0.0001) were significantly shorter. Conclusion: The Qmci-CN is accurate in identifying PSD and separating PSD from PSCIND in patients post-stroke following rehabilitation and is comparable to the widely-used MoCA-CN, albeit with a significantly shorter administration time. The Qmci-CN had relatively poor accuracy in identifying PSCIND from NC and hence may lack accuracy for certain subgroups. However, given the small sample size, the study is under-powered to show superiority of one instrument over another. Further study is needed to confirm these findings in a larger sample size and in other settings (countries and languages).
Collapse
Affiliation(s)
- Yangfan Xu
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Lingrong Yi
- Department of Rehabilitation Medicine, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Yangyang Lin
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Suiying Peng
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Weiming Wang
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Wujian Lin
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Peize Chen
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Weichao Zhang
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yujie Deng
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Suimin Guo
- Center for Child Health and Mental Health, Shenzhen Children's Hospital, Shenzhen, China
| | - Le Shi
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yuling Wang
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - D William Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr's Hospital, Cork, Ireland.,Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland
| | - Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr's Hospital, Cork, Ireland.,Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland.,Clinical Sciences Institute, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
9
|
O'Caoimh R, Gao Y, Svendrovski A, Illario M, Iaccarino G, Yavuz BB, Kehoe PG, Molloy DW. Effect of Visit-to-Visit Blood Pressure Variability on Cognitive and Functional Decline in Mild to Moderate Alzheimer's Disease. J Alzheimers Dis 2020; 68:1499-1510. [PMID: 30909214 DOI: 10.3233/jad-180774] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND Visit-to-visit blood pressure (BP) variability (VVV) is increasingly recognized as a marker of cardiovascular risk. Although implicated in cognitive decline, few studies are currently available assessing its effects on established dementia. OBJECTIVE To investigate if VVV is associated with one-year rate of decline in measures of cognition and function in patients with mild to moderate Alzheimer's disease (AD) in the Doxycycline And Rifampicin for Alzheimer's Disease study. METHODS Patients were included if ≥3 BP readings were available (n = 392). VVV was defined using different approaches including the coefficient of variation (CV) in BP readings between visits. Outcomes included rates of decline in the Standardized Alzheimer's Disease Assessment Scale-Cognitive Subscale (SADAS-cog), Standardized MMSE, Clinical Dementia Rating Scale, the Quick Mild Cognitive Impairment screen and the Lawton-Brody activities of daily living (ADL) scale. RESULTS Half of the patients (196/392) had a ≥4-point decline in the SADAS-cog over one-year. Using this cut-off, there were no statistically significant associations between any measures of VVV, for systolic or diastolic BP, with and without adjustment for potential confounders including treatment allocation, history of hypertension and use of anti-hypertensive and cognitive enhancing medications. Multiple regression models examining the association between systolic BP CV by quartile and decline over one-year likewise showed no clinically significant effects, apart from a U-shaped pattern of ADL decline of borderline clinical significance.∥Conclusions: This observational study does not support recent research showing that VVV predicts cognitive decline in AD. Further studies are needed to clarify its effects on ADL in AD.
Collapse
Affiliation(s)
- Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork, Ireland.,Health Research Board Clinical Research Facility Galway, National University of Ireland, Galway, Geata an Eolais, University Road, Galway, Ireland
| | - Yang Gao
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork, Ireland
| | | | - Maddalena Illario
- Division on Health Innovation, Campania Region Health Directorate; DISMET/R&D Unit, Federico II University and Hospital, Naples, Italy
| | - Guido Iaccarino
- Department of Medicine and Surgery, University of Salerno, Baronissi, SA, Italy
| | - Burcu Balam Yavuz
- Department of Internal Medicine, Division of Geriatric Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Patrick Gavin Kehoe
- Department of Internal Medicine, Division of Geriatric Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - D William Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork, Ireland
| |
Collapse
|
10
|
Xu Y, Lin Y, Yi L, Li Z, Li X, Yu Y, Guo Y, Wang Y, Jiang H, Chen Z, Svendrovski A, Gao Y, Molloy DW, O'Caoimh R. Screening for Cognitive Frailty Using Short Cognitive Screening Instruments: Comparison of the Chinese Versions of the MoCA and Q mci Screen. Front Psychol 2020; 11:558. [PMID: 32308636 PMCID: PMC7145973 DOI: 10.3389/fpsyg.2020.00558] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 03/09/2020] [Indexed: 02/05/2023] Open
Abstract
Background Cognitive frailty describes cognitive impairment associated with physical decline. Few studies have explored whether short cognitive screens identify frailty. We examined the diagnostic accuracy of the Chinese versions of the Quick Mild Cognitive Impairment (Qmci-CN) screen and Montreal Cognitive Assessment (MoCA-CN) in identifying cognitive frailty. Methods Ninety-five participants with cognitive symptoms [47 with mild cognitive impairment (MCI), 34 with subjective cognitive disorder, and 14 with dementia] were included from two outpatient rehabilitation clinics. Energy (work intensity) and physical activity levels were recorded. Cognitive frailty was diagnosed by an interdisciplinary team using the IANA/IAGG consensus criteria, stratified on the Clinical Frailty Scale (CFS). Instruments were administered sequentially and randomly by trained assessors, blind to the diagnosis. Results The mean age of the sample was 62.6 ± 10.2 years; median CFS score was 4 ± 1 and 36 (38%) were cognitively frail. The Qmci-CN had similar accuracy in differentiating the non-frail from cognitively frail compared to the MoCA-CN, AUC 0.82 versus 0.74, respectively (p = 0.19). At its optimal cut-off (≤55/100), the Qmci-CN provided a sensitivity of 83% and specificity of 67% versus 91% and 51%, respectively, for the MoCA-CN (≤23/30). Neither was accurate in separating MCI from cognitive frailty but both accurately separated cognitive frailty from dementia. Conclusion Established short cognitive screens may be useful in identifying cognitive frailty in Chinese adults with cognitive complaints but not in separating MCI from cognitive frailty. The Qmci-CN had similar accuracy to the MoCA-CN and a shorter administration time in this small and under-powered study, necessitating the need for adequately powered studies in different healthcare settings.
Collapse
Affiliation(s)
- Yangfan Xu
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yangyang Lin
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Lingrong Yi
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.,Department of Rehabilitation Medicine, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Zhao Li
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.,Department of Rehabilitation Medicine, Mianzhu Hospital of West China Hospital, Sichuan University, Chengdu, China
| | - Xian Li
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Yuying Yu
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.,Department of Rehabilitation Medicine, The Second People's Hospital of Foshan, Foshan, China
| | - Yuxiao Guo
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.,UCL Division of Surgery and Interventional Science, London, United Kingdom
| | - Yuling Wang
- Department of Rehabilitation Medicine, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Haoying Jiang
- Department of Rehabilitation Medicine, The First Affiliated Hospital of Jinan University, Guangzhou, China.,Department of Rehabilitation Medicine, Jilin Provincial People's Hospital, Jilin, China
| | - Zhuoming Chen
- Department of Rehabilitation Medicine, The First Affiliated Hospital of Jinan University, Guangzhou, China
| | | | - Yang Gao
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr's Hospital, Cork, Ireland
| | - D William Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr's Hospital, Cork, Ireland.,Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland
| | - Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr's Hospital, Cork, Ireland.,Department of Geriatric Medicine, Mercy University Hospital, Cork, Ireland.,Clinical Sciences Institute, National University of Ireland Galway, Galway, Ireland
| |
Collapse
|
11
|
Glynn K, Coen R, Lawlor BA. Is the Quick Mild Cognitive Impairment Screen (QMCI) more accurate at detecting mild cognitive impairment than existing short cognitive screening tests? A systematic review of the current literature. Int J Geriatr Psychiatry 2019; 34:1739-1746. [PMID: 31418473 DOI: 10.1002/gps.5201] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 08/11/2019] [Indexed: 11/05/2022]
Abstract
OBJECTIVES Differentiating normal cognition, mild cognitive impairment (MCI), and dementia is important, as these conditions differ in terms of their prognosis and treatment. Existing short cognitive screening tests vary widely in their accuracy, sensitivity, and specificity at detecting MCI and dementia. The Quick Mild Cognitive Impairment Screen (QMCI) was developed in 2012 as a fast and accurate "MCI specific" screening test. The aim of the current study was to conduct a literature review to compare the accuracy, sensitivity, and specificity of the QMCI at differentiating normal cognition, MCI, and dementia to existing short cognitive screening tests at their optimal cut-off scores. METHODS A search of the electronic journal databases EBSCO, Psych info, and Science Direct was undertaken using the keywords "Quick Mild Cognitive Impairment Screen," "QMCI," "accuracy," "sensitivity," and "specificity." Results of individual studies were examined, and 2 × 2 tables were drawn up to obtain the overall accuracy, sensitivity, and specificity of each test across the studies included. RESULTS Results from individual studies show that the QMCI has higher accuracy at detecting MCI and dementia than these cognitive screens. Pooled analysis shows that it also has greater sensitivity and specificity at optimal cut-off points for each test. CONCLUSIONS Based in the current review, the QMCI represents a more accurate, sensitive, and specific screening test for MCI and dementia than the SMMSE or the MoCA. This has important implications in screening for cognitive impairment.
Collapse
Affiliation(s)
- Kevin Glynn
- Psychiatry of Old Age, Beaumont Hospital, Dublin, Ireland
| | - Robert Coen
- Memory Clinic, MISA Building, St. James's Hospital, Dublin, Ireland
| | - Brian A Lawlor
- Memory Clinic, MISA Building, St. James's Hospital, Dublin, Ireland
| |
Collapse
|
12
|
Selecting a Bedside Cognitive Vital Sign to Monitor Cognition in Hospital: Feasibility, Reliability, and Responsiveness of Logical Memory. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16193545. [PMID: 31546698 PMCID: PMC6801972 DOI: 10.3390/ijerph16193545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 09/15/2019] [Accepted: 09/19/2019] [Indexed: 11/17/2022]
Abstract
Although there is a high prevalence of delirium and cognitive impairment among hospitalised older adults, short, reliable cognitive measures are rarely used to monitor cognition and potentially alert healthcare professionals to early changes that might signal delirium. We evaluated the reliability, responsiveness, and feasibility of logical memory (LM), immediate verbal recall of a short story, compared to brief tests of attention as a bedside “cognitive vital sign” (CVS). Trained nursing staff performed twice-daily cognitive assessments on 84 clinically stable inpatients in two geriatric units over 3–5 consecutive days using LM and short tests of attention and orientation including months of the year backwards. Scores were compared to those of an expert rater. Inter-rater reliability was excellent with correlation coefficients for LM increasing from r = 0.87 on day 1 to r = 0.97 by day 4 (p < 0.0001). A diurnal fluctuation of two points from a total of 30 was deemed acceptable in clinically stable patients. LM scores were statistically similar (p = 0.98) with repeated testing (suggesting no learning effect). All nurses reported that LM was feasible to score routinely. LM is a reliable measure of cognition showing diurnal variation but minimal learning effects. Further study is required to define the properties of an ideal CVS test, though LM may satisfy these.
Collapse
|
13
|
Comparing the Diagnostic Accuracy of Two Cognitive Screening Instruments in Different Dementia Subtypes and Clinical Depression. Diagnostics (Basel) 2019; 9:diagnostics9030093. [PMID: 31398811 PMCID: PMC6787633 DOI: 10.3390/diagnostics9030093] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 08/06/2019] [Accepted: 08/06/2019] [Indexed: 12/23/2022] Open
Abstract
Short but accurate cognitive screening instruments are required in busy clinical practice. Although widely-used, the diagnostic accuracy of the standardised Mini-Mental State Examination (SMMSE) in different dementia subtypes remains poorly characterised. We compared the SMMSE to the Quick Mild Cognitive Impairment (Qmci) screen in patients (n = 3020) pooled from three memory clinic databases in Canada including those with mild cognitive impairment (MCI) and Alzheimer’s, vascular, mixed, frontotemporal, Lewy Body and Parkinson’s dementia, with and without co-morbid depression. Caregivers (n = 875) without cognitive symptoms were included as normal controls. The median age of patients was 77 (Interquartile = ±9) years. Both instruments accurately differentiated cognitive impairment (MCI or dementia) from controls. The SMMSE most accurately differentiated Alzheimer’s (AUC 0.94) and Lewy Body dementia (AUC 0.94) and least accurately identified MCI (AUC 0.73), vascular (AUC 0.74), and Parkinson’s dementia (AUC 0.81). The Qmci had statistically similar or greater accuracy in distinguishing all dementia subtypes but particularly MCI (AUC 0.85). Co-morbid depression affected accuracy in those with MCI. The SMMSE and Qmci have good-excellent accuracy in established dementia. The SMMSE is less suitable in MCI, vascular and Parkinson’s dementia, where alternatives including the Qmci screen may be used. The influence of co-morbid depression on scores merits further investigation.
Collapse
|
14
|
Jansen-Kosterink S, van Velsen L, Frazer S, Dekker-van Weering M, O'Caoimh R, Vollenbroek-Hutten M. Identification of community-dwelling older adults at risk of frailty using the PERSSILAA screening pathway: a methodological guide and results of a large-scale deployment in the Netherlands. BMC Public Health 2019; 19:504. [PMID: 31053090 PMCID: PMC6500037 DOI: 10.1186/s12889-019-6876-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 04/22/2019] [Indexed: 02/07/2023] Open
Abstract
Background Among community-dwelling older adults, frailty is highly prevalent and recognized as a major public health concern. To prevent frailty it is important to identify those at risk of becoming frail, but at present, no accepted screening procedure is available. Methods The screening process developed as part of the PERSSILAA project is a two-step screening pathway. First, older adults are asked to complete a self-screening questionnaire to assess their general health status and their level of decline on physical, cognitive and nutritional domains. Second, older adults who, according to step one, are at risk of becoming frail, are invited for a face-to-face assessment focusing on the domains in depth. We deployed the PERSSILAA screening procedure in primary care in the Netherlands. Results In total, baseline data were available for 3777 community-dwelling older adults (mean age 69.9 (SD ± 3.8)) who completed first step screening. Based on predefined cut-off scores, 16.8% of the sample were classified as frail (n = 634), 20.6% as pre-frail (n = 777), and 62.3% as robust (n = 2353). Frail subjects were referred back to their GP without going through the second step. Of the pre-frail older adults, 69.7% had evidence of functional decline on the physical domain, 67% were overweight or obese and 31.0% had evidence of cognitive decline. Conclusion Pre-frailty is common among community-dwelling older adults. The PERSSILAA screening approach is a multi-factor, two-step screening process, potentially useful for primary prevention to identify those at risk of frailty and who will benefit most from preventive strategies.
Collapse
Affiliation(s)
- Stephanie Jansen-Kosterink
- Roessingh Research and Development, Roessinghsbleekweg 33b, 7522, AL, Enschede, The Netherlands. .,University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Telemedicine group, Enschede, the Netherlands.
| | - Lex van Velsen
- Roessingh Research and Development, Roessinghsbleekweg 33b, 7522, AL, Enschede, The Netherlands.,University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Telemedicine group, Enschede, the Netherlands
| | - Sanne Frazer
- Roessingh Research and Development, Roessinghsbleekweg 33b, 7522, AL, Enschede, The Netherlands.,University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Telemedicine group, Enschede, the Netherlands
| | - Marit Dekker-van Weering
- Roessingh Research and Development, Roessinghsbleekweg 33b, 7522, AL, Enschede, The Netherlands.,University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Telemedicine group, Enschede, the Netherlands
| | - Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, Cork City, Ireland.,Clinical Sciences Institute, National University of Ireland Galway, Galway City, Ireland
| | - Miriam Vollenbroek-Hutten
- University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Telemedicine group, Enschede, the Netherlands.,ZiekenhuisGroep Twente (ZGT), scientific office ZGT academie, Almelo, the Netherlands
| |
Collapse
|
15
|
Validity of the Japanese Version of the Quick Mild Cognitive Impairment Screen. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16060917. [PMID: 30875774 PMCID: PMC6466607 DOI: 10.3390/ijerph16060917] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 02/28/2019] [Accepted: 03/08/2019] [Indexed: 01/04/2023]
Abstract
Early detection of dementia provides opportunities for interventions that could delay or prevent its progression. We developed the Japanese version of the Quick Mild Cognitive Impairment (Qmci-J) screen, which is a performance-based, easy-to-use, valid and reliable short cognitive screening instrument, and then we examined its validity. Community-dwelling adults aged 65–84 in Niigata prefecture, Japan, were concurrently administered the Qmci-J and the Japanese version of the standardized Mini-Mental State Examination (sMMSE-J). Mild cognitive impairment (MCI) and dementia were categorized using established and age-adjusted sMMSE-J cut-offs. The sample (n = 526) included 52 (9.9%) participants with suspected dementia, 123 (23.4%) with suspected MCI and 351 with likely normal cognition. The Qmci-J showed moderate positive correlation with the sMMSE-J (r = 0.49, p < 0.001) and moderate discrimination for predicting suspected cognitive impairment (MCI/dementia) based on sMMSE-J cut-offs, area under curve: 0.74, (95%CI: 0.70–0.79), improving to 0.76 (95%CI: 0.72 to 0.81) after adjusting for age. At a cut-off of 60/61/100, the Qmci-J had a 73% sensitivity, 68% specificity, 53% positive predictive value, and 83% negative predictive value for cognitive impairment. Normative data are presented, excluding those with any sMMSE-J < 27. Though further research is required, the Qmci-J screen may be a useful screening tool to identify older adults at risk of cognitive impairment.
Collapse
|
16
|
The Italian version of the quick mild cognitive impairment (Qmci-I) screen: normative study on 307 healthy subjects. Aging Clin Exp Res 2019; 31:353-360. [PMID: 29949025 DOI: 10.1007/s40520-018-0981-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 05/30/2018] [Indexed: 10/14/2022]
Abstract
OBJECTIVE To devise an Italian version of the quick mild cognitive impairment screen (Qmci) and to obtain normative data. METHODS An Italian version of the Qmci screen (Qmci-I) was administered to 307 subjects free from cognitive impairment. The normative sample was divided into three age levels (50-59; 60-69 and 70-80 years) and four education levels (3-5; 6-8; 9-13; >13 years of school attendance). Multiple regression analyses were used to evaluate the effect of age, sex and schooling on Qmci-I scores (overall and by domains) and to calculate cut-off values, with reference to the confidence interval on the fifth centile. RESULTS The mean Qmci-I score was 64/100 (SD = 11). The age variable showed a significant negative effect on the overall Qmci-I score, with older people performing worse than younger ones. Conversely, education was associated with higher scores. Significant effects of age and education affected logical memory alone. For the other domains, the following effects were found: (1) higher age associated with lower scores on delayed recall; (2) higher education levels associated with higher scores on immediate recall, clock drawing and word fluency. The adjusted cut-off score for the Qmci-I screen in this sample was 49.4. Qmci-I scores were weakly correlated with those of MMSE (rho = 0.20). CONCLUSIONS The Qmci-I is a rapid and multi-domain short cognitive screening instrument useful for evaluating cognitive functions. However, like other screening tools, it is significantly influenced by age and education, requiring normative data and correction of values when used in the clinical practice.
Collapse
|
17
|
Machado dos Santos P, O’Caoimh R, Svendrovski A, Casanovas C, Orfila Pernas F, Illario M, Molloy W, Paul C. The RAPid COmmunity COGnitive screening Programme (RAPCOG): Developing the Portuguese version of the Quick Mild Cognitive Impairment (Q mci-P) screen as part of the EIP on AHA Twinning Scheme. Transl Med UniSa 2019; 19:82-89. [PMID: 31360671 PMCID: PMC6581493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
As populations age and the prevalence of cognitive impairment increases, healthcare professionals and researchers require short, validated cognitive screening instruments (CSIs). As part the EIP-on-AHA Twinning Support Scheme (2016), four reference sites developed the RAPid COmmunity COGnitive screening Programme (RAPCOG) twinning project to validate translated versions of the Quick Mild Cognitive Impairment (Qmci) screen that could be adapted quickly for use with future eHealth screening and assessment programmes. Here we present the cultural adaption and translation of the Qmci-Portuguese (Qmci-P) screen as part of RAPCOG and explore its subsequent validation against two commonly-used CSIs (MMSE-P and MoCA-P) with 93 participants aged ≥65, attending ten day care centres or resident in two long-term care institutions; median age 74 (+/-15), 66% female. The Qmci-P's internal consistency was high (Cronbach's Alpha 0.82), compared with the MoCA (0.79) and SMMSE (0.54). Qmci-P screen scores moderately correlated with the SMMSE (r=0.61, 95% CI:0.45-0.72, p<0.001) and MoCA (r=0.63, 95% CI:0.36-0.80, p<0.001). The Qmci-P screen demonstrates high internal consistency and concurrent validity against more established CSIs and given its brevity (3-5mins), may be preferable for use in community settings. This project shows the potential of the EIP-on-AHA Twinning initiative to promote the scaling-up of innovative good practices.
Collapse
Affiliation(s)
- P Machado dos Santos
- Center for Health Technology and Services Research/ICBAS, Institute of Biomedical Sciences Abel Salazar – University of Porto, Porto, Portugal
| | - R O’Caoimh
- Health Research Board, Clinical Research Facility Galway, National University of Ireland, Galway, Ireland,Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr’s Hospital, Douglas Road, Cork City, Ireland,Dr. Rónán O’Caoimh,
| | - A Svendrovski
- UZIK Consulting Inc., 86 Gerrard St E, Unit 12D, Toronto, ON, M5B 2J1 Canada
| | - C Casanovas
- Institut Universitari d’Investigació en Atenció Primaria Jordi Gol (IDIAP JGol), Barcelona, Spain
| | - F Orfila Pernas
- Institut Universitari d’Investigació en Atenció Primaria Jordi Gol (IDIAP JGol), Barcelona, Spain
| | - M Illario
- Division on Health Innovation, Campania Region Health Directorate; DISMET/R&D Unit, Federico II University & Hospital, Naples, Italy
| | - W Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarr’s Hospital, Douglas Road, Cork City, Ireland
| | - C Paul
- Center for Health Technology and Services Research/ICBAS, Institute of Biomedical Sciences Abel Salazar – University of Porto, Porto, Portugal
| |
Collapse
|
18
|
Lee MT, Chang WY, Jang Y. Psychometric and diagnostic properties of the Taiwan version of the Quick Mild Cognitive Impairment screen. PLoS One 2018; 13:e0207851. [PMID: 30507928 PMCID: PMC6277119 DOI: 10.1371/journal.pone.0207851] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 11/07/2018] [Indexed: 01/06/2023] Open
Abstract
There is a need for a screening tool with capacities of accurate detection of early mild cognitive impairment (MCI) and dementia and is suitable for use in a range of languages and cultural contexts. This research aims to evaluate the psychometric and diagnostic properties of the Taiwan version of Qmci (Qmci-TW) screen and to explore the discriminating ability of the Qmci-TW in differentiating among normal controls (NCs), MCI and dementia. Thirty-one participants with dementia and 36 with MCI and 35 NCs were recruited from a neurology department of regional hospital in Taiwan. Their results on the Qmci-TW, Taiwanese version of the Montreal Cognitive Assessment (MoCA), and Traditional Chinese version of the Mini–Mental State Examination (MMSE) were compared. For analysis, we used Cronbach’s α, intraclass correlation coefficient, Spearman’s ρ, Kruskal–Wallis test, receiver operating characteristic curve analysis, and multivariate analysis, as appropriate. The Qmci-TW exhibited satisfactory test–retest reliability, internal consistency, and interrater reliability as well as a strong positive correlation with results from the MoCA and MMSE. The optimal cut-off score on the Qmci-TW for differentiating MCI from NC was ≤ 51.5/100 and dementia from MCI was ≤ 31/100. The MoCA exhibited the highest accuracy in differentiating MCI from NC, followed by the Qmci-TW and then MMSE; whereas, the Qmci-TW and MMSE exhibited the same accuracy in differentiating dementia from MCI, followed by the MoCA. The Qmci-TW may be a useful clinical screening tool for a spectrum of cognitive impairments.
Collapse
Affiliation(s)
- Meng-Ta Lee
- School of Occupational Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan
- Division of Occupational Therapy, Taipei Hospital, Ministry of Health and Welfare, New Taipei, Taiwan
| | - Wan-Ying Chang
- Division of Occupational Therapy, Taipei Hospital, Ministry of Health and Welfare, New Taipei, Taiwan
| | - Yuh Jang
- School of Occupational Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
- * E-mail:
| |
Collapse
|
19
|
Oliveira FD, Kuznier TP, Souza CCD, Chianca TCM. ASPECTOS TEÓRICOS E METODOLÓGICOS PARA ADAPTAÇÃO CUTURAL E VALIDAÇÃO DE INSTRUMENTOS NA ENFERMAGEM. TEXTO & CONTEXTO ENFERMAGEM 2018. [DOI: 10.1590/0104-070720180004900016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
RESUMO Objetivo: identificar na literatura os referenciais metodológicos utilizados em estudos de adaptação cultural e validação de instrumentos na Enfermagem. Método: trata-se de uma revisão narrativa da literatura realizada a partir de um levantamento bibliográfico nas bases de dados LILACS, BDENF, IBECS, SciELO e PubMed em agosto e setembro de 2016. Resultados: analisou-se um total de 28 artigos. O referencial metodológico que tem sido utilizado para a adaptação cultural de instrumentos com maior frequência (22-78,57%) é o proposto por Beaton, Bombardier, Guillemin e Ferraz (2007); Beaton, Bombardier, Guillemin e Ferraz (2000) e Guillemin, Bombardier, Beaton. (1993). Esses autores propõem cinco etapas: tradução, síntese, retrotradução, comitê de juízes e pré-teste. A validação é classificada em três categorias: validade de conteúdo, de critério e de construto. Este estudo apontou que os critérios mais utilizados para a validação de instrumentos têm sido a validação de conteúdo (18-64,28%), de construto (13-46,43 %) e a validação de face (9-32,14%). Conclusão: nas pesquisas desenvolvidas na enfermagem tem sido valorizado seguimento de método criterioso com uso de instrumentos confiáveis e válidos. Neste sentido, o presente estudo tratou de referenciais empregados para a adaptação cultural e validação de instrumentos de medida. Identificou-se nos trabalhos os referenciais metodológicos mais empregados, os tipos de validação utilizados e os métodos que devem ser estimulados para garantir a confiabilidade e validade dos instrumentos.
Collapse
|
20
|
O'Caoimh R, Gao Y, Svendovski A, Gallagher P, Eustace J, Molloy DW. Comparing Approaches to Optimize Cut-off Scores for Short Cognitive Screening Instruments in Mild Cognitive Impairment and Dementia. J Alzheimers Dis 2018; 57:123-133. [PMID: 28222528 PMCID: PMC5345649 DOI: 10.3233/jad-161204] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Although required to improve the usability of cognitive screening instruments (CSIs), the use of cut-off scores is controversial yet poorly researched. OBJECTIVE To explore cut-off scores for two short CSIs: the Standardized Mini-Mental State Examination (SMMSE) and Quick Mild Cognitive Impairment (Qmci) screen, describing adjustments in scores for diagnosis (MCI or dementia), age (≤, >75 years), and education (<, ≥12 years), comparing two methods: the maximal accuracy approach, derived from receiver operating characteristic curves, and Youden's Index. METHODS Pooled analysis of assessments from patients attending memory clinics in Canada between 1999-2010 : 766 with mild cognitive impairment (MCI) and 1,746 with dementia, and 875 normal controls. RESULTS The Qmci was more accurate than the SMMSE in differentiating controls from MCI or cognitive impairment (MCI and dementia). Employing the maximal accuracy approach, the optimal SMMSE cut-off for cognitive impairment was <28/30 (AUC 0.86, sensitivity 74%, specificity 88%) versus <63/100 for the Qmci (AUC 0.93, sensitivity 85%, specificity 85%). Using Youden's Index, the optimal SMMSE cut-off remained <28/30 but fell slightly to <62/100 for the Qmci (sensitivity 83%, specificity 87%). The optimal cut-off for MCI was <29/30 for the SMMSE and <67/100 for the Qmci, irrespective of technique. The maximal accuracy approach generally produced higher Qmci cut-offs than Youden's Index, both requiring adjustment for age and education. There were no clinically meaningful differences in SMMSE cut-off scores by age and education or method employed. CONCLUSION Caution should be exercised selecting cut-offs as these differ by age, education, and method of derivation, with the extent of adjustment varying between CSIs.
Collapse
Affiliation(s)
- Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork City, Ireland.,Health Research Board, Clinical Research Facility Galway, National University of Ireland, Galway, Ireland
| | - Yang Gao
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork City, Ireland
| | | | - Paul Gallagher
- Department of Geriatric Medicine, Cork University Hospital, Wilton, Cork City, Ireland
| | - Joseph Eustace
- Health Research Board, Clinical Research Facility Cork, Mercy Univeristy Hospital, Cork City, Ireland
| | - D William Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork City, Ireland
| |
Collapse
|
21
|
Clarnette R, Goh M, Bharadwaj S, Ryan J, Ellis S, Svendrovski A, Molloy DW, O'Caoimh R. Screening for cognitive impairment in an Australian aged care assessment team as part of comprehensive geriatric assessment. AGING NEUROPSYCHOLOGY AND COGNITION 2018; 26:336-347. [PMID: 29448875 DOI: 10.1080/13825585.2018.1439447] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Accurate detection of mild cognitive impairment (MCI) is important to stratify and address risk. Yet, few short cognitive screening instruments are validated for this. . In Australia, all clients referred to an Aged Care Assessment Team (ACAT) receive comprehensive geriatric assessment (CGA) including the Standardized Mini-Mental State Examination (SMMSE). We compared the accuracy of the quick mild cognitive impairment (Qmci) screen to the SMMSE in 283 participants: 195 with dementia, 47 with MCI, and 41 with subjective cognitive decline (SCD) in an Australian community-based ACAT. Both had similar accuracy in identifying dementia, AUC of 0.86 for the Qmci versus 0.93 for the SMMSE (p = 0.10), but the Qmci was more accurate than the SMMSE in differentiating MCI from SCD, AUC of 0.84 versus 0.71, respectively, p = 0.046. These suggest that the new, short (3-5 min) Qmci screenis appropriate for use in an ACAT or other units conducting CGA.
Collapse
Affiliation(s)
- Roger Clarnette
- a School of Medicine and Pharmacology , University of Western Australia , Crawley , Australia.,b Department of Community and Geriatric Medicine , Fremantle Hospital and Health Service , Fremantle , Australia
| | - Ming Goh
- b Department of Community and Geriatric Medicine , Fremantle Hospital and Health Service , Fremantle , Australia
| | - Sneha Bharadwaj
- b Department of Community and Geriatric Medicine , Fremantle Hospital and Health Service , Fremantle , Australia
| | - Jillian Ryan
- b Department of Community and Geriatric Medicine , Fremantle Hospital and Health Service , Fremantle , Australia
| | - Suzanne Ellis
- b Department of Community and Geriatric Medicine , Fremantle Hospital and Health Service , Fremantle , Australia
| | | | - D William Molloy
- d Centre for Gerontology and Rehabilitation , University College Cork, St Finbarr's Hospital , Cork City , Ireland
| | - Rónán O'Caoimh
- d Centre for Gerontology and Rehabilitation , University College Cork, St Finbarr's Hospital , Cork City , Ireland.,e Health Research Board, Clinical Research Facility Galway , National University of Ireland , Galway , Ireland
| |
Collapse
|
22
|
Clarnette R, O'Caoimh R, Antony DN, Svendrovski A, Molloy DW. Comparison of the Quick Mild Cognitive Impairment (Qmci) screen to the Montreal Cognitive Assessment (MoCA) in an Australian geriatrics clinic. Int J Geriatr Psychiatry 2017; 32:643-649. [PMID: 27427212 DOI: 10.1002/gps.4505] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 03/30/2016] [Accepted: 04/19/2016] [Indexed: 11/08/2022]
Abstract
INTRODUCTION The Montreal Cognitive Assessment (MoCA) accurately differentiates mild cognitive impairment (MCI) from mild dementia and normal controls (NC). While the MoCA is validated in multiple clinical settings, few studies compare it with similar tests also designed to detect MCI. We sought to investigate how the shorter Quick Mild Cognitive Impairment (Qmci) screen compares with the MoCA. METHODS Consecutive referrals presenting with cognitive complaints to a teaching hospital geriatric clinic (Fremantle, Western Australia) underwent a comprehensive assessment and were classified as MCI (n = 72) or dementia (n = 109). NC (n = 41) were a sample of convenience. The Qmci and MoCA were scored by trained geriatricians, in random order, blind to the diagnosis. RESULTS Median Qmci scores for NC, MCI and dementia were 69 (+/-19), 52.5 (+/-12) and 36 (+/-14), respectively, compared with 27 (+/-5), 22 (+/-4) and 15 (+/-7) for the MoCA. The Qmci more accurately identified cognitive impairment (MCI or dementia), area under the curve (AUC) 0.97, than the MoCA (AUC 0.92), p = 0.04. The Qmci was non-significantly more accurate in distinguishing MCI from controls (AUC 0.91 vs 0.84, respectively = 0.16). Both instruments had similar accuracy for differentiating MCI from dementia (AUC of 0.91 vs 0.88, p = 0.35). At the optimal cut-offs, calculated from receiver operating characteristic curves, the Qmci (≤57) had a sensitivity of 91% and specificity of 93% for cognitive impairment, compared with 87% sensitivity and 80% specificity for the MoCA (≤23). CONCLUSION While both instruments are accurate in detecting MCI, the Qmci is shorter and arguably easier to complete, suggesting that it is a useful instrument in an Australian geriatric outpatient population. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Roger Clarnette
- School of Medicine and Pharmacology, The University of Western Australia, Perth, WA, Australia.,Department of Community and Geriatric Medicine, Fremantle Hospital and Health Service, Perth, Western Australia, Australia
| | - Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork City, Ireland.,Health Research Board, Clinical Research Facility Galway, National University of Ireland, Galway, Ireland
| | - Deanna N Antony
- Department of Community and Geriatric Medicine, Fremantle Hospital and Health Service, Perth, Western Australia, Australia
| | | | - D William Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork City, Ireland
| |
Collapse
|
23
|
Yavuz BB, Varan HD, O’Caoimh R, Kizilarslanoglu MC, Kilic MK, Molloy DW, Dogrul RT, Karabulut E, Svendrovski A, Sağır A, Cankurtaran ES, Yesil Y, Kuyumcu ME, Halil M, Cankurtaran M. Validation of the Turkish Version of the Quick Mild Cognitive Impairment Screen. Am J Alzheimers Dis Other Demen 2017; 32:145-156. [PMID: 28423938 PMCID: PMC10852850 DOI: 10.1177/1533317517691122] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The objective of this study was to validate the Turkish version of the Quick Mild Cognitive Impairment (Q mci-TR) screen. METHODS In total, 100 patients aged ≥65 years referred to a geriatric outpatient clinic with memory loss were included. The Q mci was compared to the Turkish versions of the standardized Mini-Mental State Examination and the Montreal Cognitive Assessment (MoCA). RESULTS The Q mci-TR had higher accuracy than the MoCA in discriminating subjective memory complaints (SMCs) from cognitive impairment (mild cognitive impairment [MCI] or dementia), of borderline significance after adjusting for age and education ( P = .06). The Q mci-TR also had higher accuracy than the MoCA in differentiating MCI from SMC, which became nonsignificant after adjustment ( P = .15). A similar pattern was shown for distinguishing MCI from dementia. Test reliability for the Q mci-TR was strong. CONCLUSION The Q mci-TR is a reliable and useful screening tool for discriminating MCI from SMC and dementia in a Turkish population.
Collapse
Affiliation(s)
- Burcu Balam Yavuz
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Hacer Dogan Varan
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Rónán O’Caoimh
- Centre for Gerontology and Rehabilitation, St Finbarr’s Hospital, University College Cork, Cork, Ireland
- Health Research Board, Clinical Research Facility, National University of Ireland, Galway, Ireland
| | - Muhammet Cemal Kizilarslanoglu
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Mustafa Kemal Kilic
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - D. William Molloy
- Centre for Gerontology and Rehabilitation, St Finbarr’s Hospital, University College Cork, Cork, Ireland
| | - Rana Tuna Dogrul
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Erdem Karabulut
- Department of Biostatistics, Hacettepe University, Ankara, Turkey
| | | | - Aykut Sağır
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | | | - Yusuf Yesil
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Mehmet Emin Kuyumcu
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Meltem Halil
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - Mustafa Cankurtaran
- Division of Geriatric Medicine, Department of Internal Medicine, Hacettepe University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
24
|
O'Caoimh R, Timmons S, Molloy DW. Screening for Mild Cognitive Impairment: Comparison of "MCI Specific" Screening Instruments. J Alzheimers Dis 2016; 51:619-29. [PMID: 26890758 PMCID: PMC4927818 DOI: 10.3233/jad-150881] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Background: Sensitive and specific instruments are required to screen for cognitive impairment (CI) in busy clinical practice. The Montreal Cognitive Assessment (MoCA) is widely validated but few studies compare it to tests designed specifically to detect mild cognitive impairment (MCI). Objective: Comparison of two “MCI specific” screens: the Quick Mild Cognitive Impairment screen (Qmci) and MoCA. Methods: Patients with subjective memory complaints (SMC; n = 73), MCI (n = 103), or dementia (n = 274), were referred to a university hospital memory clinic and underwent comprehensive assessment. Caregivers, without cognitive symptoms, were recruited as normal controls (n = 101). Results: The Qmci was more accurate than the MoCA in differentiating MCI from controls, area under the curve (AUC) of 0.90 versus 0.80, p = 0.009. The Qmci had greater (AUC 0.81), albeit non-significant, accuracy than the MoCA (AUC 0.73) in separating MCI from SMC, p = 0.09. At its recommended cut-off (<62/100), the Qmci had a sensitivity of 90% and specificity of 87% for CI (MCI/dementia). Raising the cut-off to <65 optimized sensitivity (94%), reducing specificity (80%). At <26/30 the MoCA had better sensitivity (96%) but poor specificity (58%). A MoCA cut-off of <24 provided the optimal balance. Median Qmci administration time was 4.5 (±1.3) minutes compared with 9.5 (±2.8) for the MoCA. Conclusions: Although both tests distinguish MCI from dementia, the Qmci is particularly accurate in separating MCI from normal cognition and has shorter administration times, suggesting it is more useful in busy hospital clinics. This study reaffirms the high sensitivity of the MoCA but suggests a lower cut-off (<24) in this setting.
Collapse
Affiliation(s)
- Rónán O'Caoimh
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork, Ireland.,Health Research Board, Clinical Research Facility Galway, National University of Ireland, Galway, Geata an Eolais, University Road, Galway, Ireland
| | - Suzanne Timmons
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork, Ireland
| | - D William Molloy
- Centre for Gerontology and Rehabilitation, University College Cork, St Finbarrs Hospital, Cork, Ireland
| |
Collapse
|