1
|
Zdero R, Brzozowski P, Schemitsch EH. Biomechanical design optimization of proximal humerus locked plates: A review. Injury 2024; 55:111247. [PMID: 38056059 DOI: 10.1016/j.injury.2023.111247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/15/2023] [Accepted: 11/24/2023] [Indexed: 12/08/2023]
Abstract
BACKGROUND Proximal humerus locked plates (PHLPs) are widely used for fracture surgery. Yet, non-union, malunion, infection, avascular necrosis, screw cut-out (i.e., perforation), fixation failure, and re-operation occur. Most biomechanical investigators compare a specific PHLP configuration to other implants like non-locked plates, nails, wires, and arthroplasties. However, it is unknown whether the PHLP configuration is biomechanically optimal according to some well-known biomechanical criteria. Therefore, this is the first review of the systematic optimization of plate and/or screw design variables for improved PHLP biomechanical performance. METHODS The PubMed website was searched for papers using the terms "proximal humerus" or "shoulder" plus "biomechanics/biomechanical" plus "locked/locking plates". PHLP papers were included if they were (a) optimization studies that systematically varied plate and screw variables to determine their influence on PHLP's biomechanical performance; (b) focused on plate and screw variables rather than augmentation techniques (i.e., extra implants, bone struts, or cement); (c) published after the year 2000 signaling the commercial availability of locked plate technology; and (d) written in English. RESULTS The 41 eligible papers involved experimental testing and/or finite element modeling. Plate variables investigated by these papers were geometry, material, and/or position, while screw variables studied were number, distribution, angle, size, and/or threads. Numerical outcomes given by these papers included stiffness, strength, fracture motion, bone and implant stress, and/or the number of loading cycles to failure. But, no paper fully optimized any plate or screw variable for a PHLP by simultaneously applying four well-established biomechanical criteria: (a) allow controlled fracture motion for early callus generation; (b) reduce bone and implant stress below the material's ultimate stress to prevent failure; (c) maintain sufficient bone-plate interface stress to reduce bone resorption (i.e., stress shielding); and (d) increase the number of loading cycles before failure for a clinically beneficial lifespan (i.e., fatigue life). Finally, this review made suggestions for future work, identified clinical implications, and assessed the quality of the papers reviewed. CONCLUSIONS Applying biomechanical optimization criteria can assist biomedical engineers in designing or evaluating PHLPs, so orthopaedic surgeons can have superior PHLP constructs for clinical use.
Collapse
Affiliation(s)
- Radovan Zdero
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
| | - Pawel Brzozowski
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada.
| | - Emil H Schemitsch
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada; Division of Orthopaedic Surgery, Western University, London, ON, Canada
| |
Collapse
|
2
|
Chang HH, Lim JR, Lee KH, An H, Yoon TH, Chun YM. The biomechanical effect of fibular strut grafts on humeral surgical neck fractures with lateral wall comminution. Sci Rep 2023; 13:3744. [PMID: 36879028 PMCID: PMC9988971 DOI: 10.1038/s41598-023-30935-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 03/03/2023] [Indexed: 03/08/2023] Open
Abstract
No studies have evaluated the effect of fibular strut augmentation on the stability of locking plate fixation for osteoporotic proximal humeral fractures with lateral wall comminution. The purpose of this study was to evaluate the stability of locking plate fixation with a fibular strut graft compared with locking plate alone in an osteoporotic two-part surgical neck fracture model with lateral cortex comminution. Ten paired fresh-frozen cadaveric humeri were randomly allocated into two groups, either the locking plate alone (LP group) or locking plate with fibular strut graft augmentation (LPFSG group), with an equal number of right and left osteoporotic surgical neck fractures with lateral wall comminution of the greater tuberosity. Varus, internal/external torsion, and axial compression stiffness as well as single load to failure were measured in plate-bone constructs, and the LPFSG group showed significantly greater values in all metrics. In conclusion, this biomechanical study shows that fibular strut augmentation significantly enhances varus stiffness, internal torsion stiffness, external torsion stiffness, and maximum failure load of a construct compared to locking plate fixation alone in proximal humeral fractures with lateral wall comminution.
Collapse
Affiliation(s)
- Hsien-Hao Chang
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea
| | - Joon-Ryul Lim
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea
| | - Kil-Han Lee
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea
| | - Haemosu An
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea
| | - Tae-Hwan Yoon
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea
| | - Yong-Min Chun
- Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, 50-1 Yonsei-ro, Sinchon-dong, Seodaemun-gu, Seoul, 03722, Korea.
| |
Collapse
|
3
|
Kulkamthorn N, Rungrattanawilai N, Tarunotai T, Chuvetsereporn N, Chansela P, Phruetthiphat OA. The proximal humeral locking plate positioning to the pectoralis major tendon in achieving the proper calcar screw location: a cadaveric study. J Orthop Surg Res 2022; 17:6. [PMID: 34983577 PMCID: PMC8725298 DOI: 10.1186/s13018-021-02892-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 12/23/2021] [Indexed: 11/30/2022] Open
Abstract
Background Proximal humeral fracture is the third most common of osteoporotic fracture. Most surgical cases were treated by fixation with anatomical locking plate system. The calcar screw plays a role in medial support and improving varus stability. Proximal humerus fracture in elderly patients are commonly seen with greater tuberosity (GT) fracture. The GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. Therefore, the insertion of pectoralis major tendon (PMT) may be used as an alternative landmark for appropriate plate and calcar screw position. The purpose of study is going to identify the vertical distance from PMT to a definite point on the position of locking plate. Methods 30 cadaveric shoulders at the department of clinical anatomy were performed. Shoulders with osteoarthritic change (n = 5) were excluded. Finally, 25 soft cadaveric shoulders were recruited in this study. The PHILOS™ plate was placed 2 mm posterior to the bicipital groove. A humeral head (HH) was cut in the coronal plane at the level of the anterior border of the PHILOS plate with a saw. A calcar screw was inserted close to the inferior cortex of HH. Distance from the upper border of elongated combi-hole (UB-ECH) to the upper border of pectoralis major tendon (UB-PMT) was measured. The plate was then moved superiorly until the calcar screw was 12 mm superior to the inferior border of HH and the distance was repeatedly measured. Results The range of distance from UB-PMT to the UB-ECH was from − 4.50 ± 7.95 mm to 6.62 ± 7.53 mm, when calcar screw was close to inferior border of HH and when the calcar screw was 12 mm superior to the inferior border of HH, respectively. The highest probability of calcar screw in proper location was 72% when UB-ECH was 3 mm above UB-PMT. Discussion and conclusion The GT fragment is sometimes difficult to use as an anatomic landmark for proper plate and screw position. PMT can be used as an alternative anatomic reference. UB-PMT can serve as a guide for proper calcar screw insertion. UB-ECH should be 3 mm above UB-PMT and three-fourths of cases achieved proper calcar screw location.
Collapse
Affiliation(s)
- Nattha Kulkamthorn
- Orthopaedics Department, Phramongkutklao Hospital, 315 Ratchvidhi Road, Thung Phaya Thai, Ratchathewee, Bangkok, 10400, Thailand
| | | | - Thanakorn Tarunotai
- Department of Orthopaedic Surgery, Nopparatratchathani Hospital, Bangkok, Thailand
| | | | - Piyachat Chansela
- Department of Anatomy, Phramongkutklao College of Medicine, Bangkok, Thailand
| | - Ong-Art Phruetthiphat
- Orthopaedics Department, Phramongkutklao Hospital, 315 Ratchvidhi Road, Thung Phaya Thai, Ratchathewee, Bangkok, 10400, Thailand.
| |
Collapse
|
4
|
Liu G, Guo X, Zhao Q, Qin B, Lu J, Bao D, Fu S. A new biomechanical classification system for split fractures of the humeral greater tuberosity: guidelines for surgical treatment. J Orthop Surg Res 2021; 16:692. [PMID: 34819107 PMCID: PMC8614056 DOI: 10.1186/s13018-021-02839-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Accepted: 11/10/2021] [Indexed: 11/18/2022] Open
Abstract
Background Split fractures of the humeral greater tuberosity (HGT) are common injuries. Although there are numerous surgical treatments for these fractures, no classification system combining clinical and biomechanical characteristics has been presented to guide the choice of fixation method. Methods We created a standardised fracture of the HGT in 24 formalin-fixed cadavers. Six were left as single-fragment fractures (Group A), six were further prepared to create single-fragment with medium size full-thickness rotator cuff tear (FT-RCT) fractures (Group B), six were cut to create multi-fragment fractures (Group C), and six were cut to create multi-fragment with FT-RCT fractures (Group D). Each specimen was fixed with a shortened proximal humeral internal locking system (PHILOS) plate. The fixed fractures were subjected to load and load-to-failure tests and the differences between groups analysed. Results The mean load-to-failure values were significantly different between groups (Group A, 446.83 ± 38.98 N; Group B, 384.17 ± 36.15 N; Group C, 317.17 ± 23.32 N and Group D, 266.83 ± 37.65 N, P < 0.05). The load-to-failure values for fractures with a greater tuberosity displacement of 10 mm were significantly different between each group (Group A, 194.00 ± 29.23 N; Group B, 157.00 ± 29.97 N; Group C, 109.00 ± 17.64 N and Group D, 79.67.83 ± 15.50 N; P < 0.05). These findings indicate that fractures with a displacement of 10 mm have different characteristics and should be considered separately from other HGT fractures when deciding surgical treatment. Conclusions Biomechanical classification of split fractures of the HGT is a reliable method of categorising these fractures in order to decide surgical treatment. Our findings and proposed system will be a useful to guide the choice of surgical technique for the treatment of fractures of the HGT.
Collapse
Affiliation(s)
- Gang Liu
- Department of Orthopedics, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Center for Orthopedic Diseases Research, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Expert Workstation in Luzhou, Luzhou, Sichuan, China.,Clinical Base of Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Guangdong Province Medical 3D Printing Application Transformation Engineering Technology Research Center, Luzhou, Sichuan, China
| | - Xiaoguang Guo
- Department of Orthopedics, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Center for Orthopedic Diseases Research, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Expert Workstation in Luzhou, Luzhou, Sichuan, China.,Clinical Base of Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Guangdong Province Medical 3D Printing Application Transformation Engineering Technology Research Center, Luzhou, Sichuan, China
| | - Qian Zhao
- Department of Breast Surgery, Luzhou Hospital of Traditional Chinese Medicine, Luzhou, Sichuan, China
| | - Bo Qin
- Department of Orthopedics, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Center for Orthopedic Diseases Research, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Expert Workstation in Luzhou, Luzhou, Sichuan, China.,Clinical Base of Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Guangdong Province Medical 3D Printing Application Transformation Engineering Technology Research Center, Luzhou, Sichuan, China
| | - Junjie Lu
- Department of Orthopedics, YiXing Traditional Chinese Medicine Hospital, Yixing, Jiangsu, China
| | - Dingsu Bao
- Department of Orthopedics, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Center for Orthopedic Diseases Research, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China.,Expert Workstation in Luzhou, Luzhou, Sichuan, China.,Clinical Base of Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Guangdong Province Medical 3D Printing Application Transformation Engineering Technology Research Center, Luzhou, Sichuan, China
| | - Shijie Fu
- Department of Orthopedics, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China. .,Center for Orthopedic Diseases Research, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, Sichuan, China. .,Expert Workstation in Luzhou, Luzhou, Sichuan, China. .,Clinical Base of Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Guangdong Province Medical 3D Printing Application Transformation Engineering Technology Research Center, Luzhou, Sichuan, China.
| |
Collapse
|
5
|
Branca Vergano L, Landi S, Monesi M. Locked posterior fracture-dislocation of the shoulder. ACTA BIO-MEDICA : ATENEI PARMENSIS 2019; 90:139-146. [PMID: 31821298 PMCID: PMC7233701 DOI: 10.23750/abm.v90i12-s.8972] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Indexed: 11/23/2022]
Abstract
BACKGROUND AND AIM OF THE WORK To describe a valid option for the treatment of locked posterior fracture-dislocation of the shoulder (LPFDS) and to compare it to the literature about this topic. METHODS We present a small case series (3 patients), with a medium follow up at 4 years and 5 months. We accurately describe our surgical strategies, underlining the choice of approach, reduction and fixation. RESULTS The three patients showed excellent functional and radiological results at the follow up examinations, with a full range of shoulder movements and complete regain of pre-trauma activities. A lateral approach (standard or minimally invasive), a reduction technique with a Shantz pin in the head and in the humeral shaft, and fixation with a locking plate were used in the three patients. CONCLUSION LPFDS is a challenging lesion, hard to recognize and to treat. Our suggested method of treatment is highly reproducible and has revealed itself to be very effective in achieving good results.
Collapse
|
6
|
Kubicek J, Tomanec F, Cerny M, Vilimek D, Kalova M, Oczka D. Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2019; 19:E5199. [PMID: 31783631 PMCID: PMC6929084 DOI: 10.3390/s19235199] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/08/2019] [Accepted: 11/12/2019] [Indexed: 12/17/2022]
Abstract
Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.
Collapse
Affiliation(s)
- Jan Kubicek
- Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, FEECS, 708 00 Ostrava-Poruba, Czech Republic; (F.T.); (M.C.); (D.V.); (M.K.); (D.O.)
| | | | | | | | | | | |
Collapse
|