1
|
Andrade RL, Figueiredo J, Fonseca P, Vilas-Boas JP, Silva MT, Santos CP. Human-Robot Joint Misalignment, Physical Interaction, and Gait Kinematic Assessment in Ankle-Foot Orthoses. SENSORS (BASEL, SWITZERLAND) 2023; 24:246. [PMID: 38203110 PMCID: PMC10781370 DOI: 10.3390/s24010246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 12/24/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024]
Abstract
Lower limb exoskeletons and orthoses have been increasingly used to assist the user during gait rehabilitation through torque transmission and motor stability. However, the physical human-robot interface (HRi) has not been properly addressed. Current orthoses lead to spurious forces at the HRi that cause adverse effects and high abandonment rates. This study aims to assess and compare, in a holistic approach, human-robot joint misalignment and gait kinematics in three fixation designs of ankle-foot orthoses (AFOs). These are AFOs with a frontal shin guard (F-AFO), lateral shin guard (L-AFO), and the ankle modulus of the H2 exoskeleton (H2-AFO). An experimental protocol was implemented to assess misalignment, fixation displacement, pressure interactions, user-perceived comfort, and gait kinematics during walking with the three AFOs. The F-AFO showed reduced vertical misalignment (peak of 1.37 ± 0.90 cm, p-value < 0.05), interactions (median pressures of 0.39-3.12 kPa), and higher user-perceived comfort (p-value < 0.05) when compared to H2-AFO (peak misalignment of 2.95 ± 0.64 and pressures ranging from 3.19 to 19.78 kPa). F-AFO also improves the L-AFO in pressure (median pressures ranging from 8.64 to 10.83 kPa) and comfort (p-value < 0.05). All AFOs significantly modified hip joint angle regarding control gait (p-value < 0.01), while the H2-AFO also affected knee joint angle (p-value < 0.01) and gait spatiotemporal parameters (p-value < 0.05). Overall, findings indicate that an AFO with a frontal shin guard and a sports shoe is effective at reducing misalignment and pressure at the HRI, increasing comfort with slight changes in gait kinematics.
Collapse
Affiliation(s)
- Ricardo Luís Andrade
- Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal
| | - Joana Figueiredo
- Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga/4800-058 Guimarães, Portugal
| | - Pedro Fonseca
- Porto Biomechanics Laboratory (LABIOMEP), University of Porto, 4200-450 Porto, Portugal; (P.F.); (J.P.V.-B.)
| | - João P. Vilas-Boas
- Porto Biomechanics Laboratory (LABIOMEP), University of Porto, 4200-450 Porto, Portugal; (P.F.); (J.P.V.-B.)
- Centre of Research, Education, Innovation and Intervention in Sport (CIFI2D), Faculty of Sport, University of Porto, 4200-450 Porto, Portugal
| | - Miguel T. Silva
- IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisbon, Portugal;
| | - Cristina P. Santos
- Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal
- LABBELS—Associate Laboratory, 4710-057 Braga/4800-058 Guimarães, Portugal
| |
Collapse
|
2
|
Otlet V, Vandamme C, Warlop T, Crevecoeur F, Ronsse R. Effects of overground gait training assisted by a wearable exoskeleton in patients with Parkinson's disease. J Neuroeng Rehabil 2023; 20:156. [PMID: 37974229 PMCID: PMC10655429 DOI: 10.1186/s12984-023-01280-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 11/08/2023] [Indexed: 11/19/2023] Open
Abstract
BACKGROUND In the recent past, wearable devices have been used for gait rehabilitation in patients with Parkinson's disease. The objective of this paper is to analyze the outcome of a wearable hip orthosis whose assistance adapts in real time to the patient's gait kinematics via adaptive oscillators. In particular, this study focuses on a metric characterizing natural gait variability, i.e., the level of long-range autocorrelations (LRA) in series of stride durations. METHODS Eight patients with Parkinson's disease (Hoehn and Yahr stages 1[Formula: see text]2.5) performed overground gait training three times per week for four consecutive weeks, assisted by a wearable hip orthosis. Gait was assessed based on performance metrics such as the hip range of motion, speed, stride length and duration, and the level of LRA in inter-stride time series assessed using the Adaptive Fractal Analysis. These metrics were measured before, directly after, and 1 month after training. RESULTS After training, patients increased their hip range of motion, their gait speed and stride length, and decreased their stride duration. These improvements were maintained 1 month after training. Regarding long-range autocorrelations, the population's behavior was standardized towards a metric closer to the one of healthy individuals after training, but with no retention after 1 month. CONCLUSION This study showed that an overground gait training with adaptive robotic assistance has the potential to improve key gait metrics that are typically affected by Parkinson's disease and that lead to higher prevalence of fall. TRIAL REGISTRATION ClinicalTrials.gov Identifer NCT04314973. Registered on 11 April 2020.
Collapse
Affiliation(s)
- Virginie Otlet
- Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium.
- Institute of Neuroscience, UCLouvain, Brussels, Belgium.
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium.
| | - Clémence Vandamme
- Institute of Neuroscience, UCLouvain, Brussels, Belgium
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics, UCLouvain, Louvain-la-Neuve, Belgium
| | - Thibault Warlop
- Institute of Neuroscience, UCLouvain, Brussels, Belgium
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium
- Service de Neurologie, Centre Hospitalier de Wallonie Picarde, Tournai, Belgium
- Service de Neurologie (Pathologie du Mouvement), Centre Hospitalier Universitaire de Lille, Lille, France
| | - Frédéric Crevecoeur
- Institute of Neuroscience, UCLouvain, Brussels, Belgium
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium
- Institute of Information and Communication Technologies, Electronics and Applied Mathematics, UCLouvain, Louvain-la-Neuve, Belgium
| | - Renaud Ronsse
- Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Institute of Neuroscience, UCLouvain, Brussels, Belgium
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium
| |
Collapse
|
3
|
Otlet V, Ronsse R. Adaptive walking assistance does not impact long-range stride-to-stride autocorrelations in healthy people. J Neurophysiol 2023; 130:417-426. [PMID: 37465888 DOI: 10.1152/jn.00181.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 06/16/2023] [Accepted: 07/11/2023] [Indexed: 07/20/2023] Open
Abstract
Many studies have demonstrated in the past that the level of long-range autocorrelations in series of stride durations, characterizing natural gait variability, is impacted by external constraints, such as treadmill or metronome, or by pathologies, such as Parkinson's or Huntington's disease. Nevertheless, no one has analyzed the effects on this metric of a gait constrained by a robot-mediated walking assistance, which intrinsically tends to normalize the gait pattern. This paper focuses on the influence of a wearable active pelvis orthosis on the level of long-range autocorrelations in series of stride durations. Ten healthy participants, aged between 55 and 77 yr, performed four overground walking sessions, wearing this orthosis, and with different assistive parameters. This study showed that the adaptive assistance provided by this device has the potential of improving gait metrics that are typically affected by aging, such as the hip range of motion, walking speed, stride length, and stride duration, without impacting natural gait variability, i.e., the level of long-range autocorrelations in series of stride durations. This combination is virtuous toward the design of an assistive device for people with locomotion disorders resulting in deteriorated levels of long-range autocorrelations, such as patients with Parkinson's disease.NEW & NOTEWORTHY This study is the first that investigates the effects of a wearable active pelvis orthosis using an oscillator-based adaptive assistance on the level of long-range autocorrelations in series of stride durations during overground walking. It is also the first to compare the effects of different assistance settings on spatiotemporal gait metrics.
Collapse
Affiliation(s)
- Virginie Otlet
- Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Institute of Neuroscience, UCLouvain, Brussels, Belgium
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium
| | - Renaud Ronsse
- Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Institute of Neuroscience, UCLouvain, Brussels, Belgium
- Louvain Bionics, UCLouvain, Louvain-la-Neuve, Belgium
| |
Collapse
|
4
|
Moeller T, Moehler F, Krell-Roesch J, Dežman M, Marquardt C, Asfour T, Stein T, Woll A. Use of Lower Limb Exoskeletons as an Assessment Tool for Human Motor Performance: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:3032. [PMID: 36991743 PMCID: PMC10057915 DOI: 10.3390/s23063032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 06/19/2023]
Abstract
Exoskeletons are a promising tool to support individuals with a decreased level of motor performance. Due to their built-in sensors, exoskeletons offer the possibility of continuously recording and assessing user data, for example, related to motor performance. The aim of this article is to provide an overview of studies that rely on using exoskeletons to measure motor performance. Therefore, we conducted a systematic literature review, following the PRISMA Statement guidelines. A total of 49 studies using lower limb exoskeletons for the assessment of human motor performance were included. Of these, 19 studies were validity studies, and six were reliability studies. We found 33 different exoskeletons; seven can be considered stationary, and 26 were mobile exoskeletons. The majority of the studies measured parameters such as range of motion, muscle strength, gait parameters, spasticity, and proprioception. We conclude that exoskeletons can be used to measure a wide range of motor performance parameters through built-in sensors, and seem to be more objective and specific than manual test procedures. However, since these parameters are usually estimated from built-in sensor data, the quality and specificity of an exoskeleton to assess certain motor performance parameters must be examined before an exoskeleton can be used, for example, in a research or clinical setting.
Collapse
Affiliation(s)
- Tobias Moeller
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Felix Moehler
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Janina Krell-Roesch
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Miha Dežman
- Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Charlotte Marquardt
- Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Tamim Asfour
- Institute for Anthropomatics and Robotics, High Performance Humanoid Technologies (H2T), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Thorsten Stein
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Alexander Woll
- Institute of Sports and Sports Science, Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| |
Collapse
|
5
|
Mahmud D, Bennett ST, Zhu Z, Adamczyk PG, Wehner M, Veeramani D, Dai F. Identifying Facilitators, Barriers, and Potential Solutions of Adopting Exoskeletons and Exosuits in Construction Workplaces. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22249987. [PMID: 36560355 PMCID: PMC9785667 DOI: 10.3390/s22249987] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/14/2022] [Accepted: 12/15/2022] [Indexed: 05/31/2023]
Abstract
Exoskeletons and exosuits (collectively termed EXOs) have the potential to reduce the risk of work-related musculoskeletal disorders (WMSDs) by protecting workers from exertion and muscle fatigue due to physically demanding, repetitive, and prolonged work in construction workplaces. However, the use of EXOs in construction is in its infancy, and much of the knowledge required to drive the acceptance, adoption, and application of this technology is still lacking. The objective of this research is to identify the facilitators, barriers, and corresponding solutions to foster the adoption of EXOs in construction workplaces through a sequential, multistage Delphi approach. Eighteen experts from academia, industry, and government gathered in a workshop to provide insights and exchange opinions regarding facilitators, barriers, and potential solutions from a holistic perspective with respect to business, technology, organization, policy/regulation, ergonomics/safety, and end users (construction-trade professionals). Consensus was reached regarding all these perspectives, including top barriers and potential solution strategies. The outcomes of this study will help the community gain a comprehensive understanding of the potential for EXO use in the construction industry, which may enable the development of a viable roadmap for the evolution of EXO technology and the future of EXO-enabled workers and work in construction workplaces.
Collapse
Affiliation(s)
- Dilruba Mahmud
- Wadsworth Department of Civil and Environmental Engineering, West Virginia University, Morgantown, WV 26506, USA
| | - Sean T. Bennett
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Zhenhua Zhu
- Department of Civil and Environmental Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Peter G. Adamczyk
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Michael Wehner
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Dharmaraj Veeramani
- Department of Industrial and Systems Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Fei Dai
- Wadsworth Department of Civil and Environmental Engineering, West Virginia University, Morgantown, WV 26506, USA
| |
Collapse
|
6
|
Janowski M, Jasińska-Choromańska D, Zaczyk M. Method of Studying a Process of Turning in an Orthotic Robot. JOURNAL OF ROBOTICS AND MECHATRONICS 2022. [DOI: 10.20965/jrm.2022.p0645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper analyzes an orthotic robot’s capability of changing the direction of motion as part of its gait process while it is being worn by a user. Exoskeletons and orthotic robots are presented, focusing on their capabilities regarding the implementing a turn of their lower limbs. The devices are analyzed, and a method is proposed, being safe for the user, which ensures the required change of the angular position of the user’s trunk, having performed a turn of the device. The smallest movement of each lower limb, which is necessary to enable a turn of the trunk in such a way that the turn can be performed by both lower limbs, is determined.
Collapse
|
7
|
Proud JK, Lai DTH, Mudie KL, Carstairs GL, Billing DC, Garofolini A, Begg RK. Exoskeleton Application to Military Manual Handling Tasks. HUMAN FACTORS 2022; 64:527-554. [PMID: 33203237 DOI: 10.1177/0018720820957467] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
OBJECTIVE The aim of this review was to determine how exoskeletons could assist Australian Defence Force personnel with manual handling tasks. BACKGROUND Musculoskeletal injuries due to manual handling are physically damaging to personnel and financially costly to the Australian Defence Force. Exoskeletons may minimize injury risk by supporting, augmenting, and/or amplifying the user's physical abilities. Exoskeletons are therefore of interest in determining how they could support the unique needs of military manual handling personnel. METHOD Industrial and military exoskeleton studies from 1990 to 2019 were identified in the literature. This included 67 unique exoskeletons, for which Information about their current state of development was tabulated. RESULTS Exoskeleton support of manual handling tasks is largely through squat/deadlift (lower limb) systems (64%), with the proposed use case for these being load carrying (42%) and 78% of exoskeletons being active. Human-exoskeleton analysis was the most prevalent form of evaluation (68%) with reported reductions in back muscle activation of 15%-54%. CONCLUSION The high frequency of citations of exoskeletons targeting load carrying reflects the need for devices that can support manual handling workers. Exoskeleton evaluation procedures varied across studies making comparisons difficult. The unique considerations for military applications, such as heavy external loads and load asymmetry, suggest that a significant adaptation to current technology or customized military-specific devices would be required for the introduction of exoskeletons into a military setting. APPLICATION Exoskeletons in the literature and their potential to be adapted for application to military manual handling tasks are presented.
Collapse
Affiliation(s)
| | | | - Kurt L Mudie
- 2222 Defence Science and Technology (DST), Melbourne, Australia
| | | | | | | | | |
Collapse
|
8
|
Development of a 3D Relative Motion Method for Human-Robot Interaction Assessment. SENSORS 2022; 22:s22062411. [PMID: 35336593 PMCID: PMC8952123 DOI: 10.3390/s22062411] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 03/10/2022] [Accepted: 03/11/2022] [Indexed: 12/10/2022]
Abstract
Exoskeletons have been assessed by qualitative and quantitative features known as performance indicators. Within these, the ergonomic indicators have been isolated, creating a lack of methodologies to analyze and assess physical interfaces. In this sense, this work presents a three-dimensional relative motion assessment method. This method quantifies the difference of orientation between the user’s limb and the exoskeleton link, providing a deeper understanding of the Human–Robot interaction. To this end, the AGoRA exoskeleton was configured in a resistive mode and assessed using an optoelectronic system. The interaction quantified a difference of orientation considerably at a maximum value of 41.1 degrees along the sagittal plane. It extended the understanding of the Human–Robot Interaction throughout the three principal human planes. Furthermore, the proposed method establishes a performance indicator of the physical interfaces of an exoskeleton.
Collapse
|
9
|
De Bock S, Rossini M, Lefeber D, Rodriguez-Guerrero C, Geeroms J, Meeusen R, De Pauw K. An Occupational Shoulder Exoskeleton Reduces Muscle Activity and Fatigue During Overhead Work. IEEE Trans Biomed Eng 2022; 69:3008-3020. [PMID: 35290183 DOI: 10.1109/tbme.2022.3159094] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Objective. This paper assesses the effect of a passive shoulder exoskeleton prototype, Exo4Work, on muscle activity, muscle fatigue and subjective experience during simulated occupational overhead and non-overhead work. Methods. Twenty-two healthy males performed six simulated industrial tasks with and without Exo4Work exoskeleton in a randomized counterbalanced cross-over design. During these tasks electromyography, heart rate, metabolic cost, subjective parameters and performance parameters were acquired. The effect of the exoskeleton and the body side on these parameters was investigated. Results. Anterior deltoid activity and fatigue reduced up to 16% and 41%, respectively, during isometric overhead work, and minimized hindrance of the device during non-overhead tasks. Wearing the exoskeleton increased feelings of frustration and increased discomfort in the areas where the exoskeleton and the body interfaced. The assistive effect of the exoskeleton was less prominent during dynamic tasks. Conclusion. This exoskeleton may reduce muscle activity and delay development of muscle fatigue in an overhead working scenario. For dynamic applications, the exoskeleton's assistive profile, which mimics the gravitational torque of the arm, is potentially sub-optimal. Significance. This evaluation paper is the first to report reduced muscle fatigue and activity when working with an occupational shoulder exoskeleton providing one third of the gravitational torque of the arm during overhead work. These results stress the potential of occupational shoulder exoskeletons in overhead working situations and may direct towards longitudinal field experiments. Additionally, this experiment may stimulate future work to further investigate the effect of different assistive profiles.
Collapse
|
10
|
Hoffmann N, Prokop G, Weidner R. Methodologies for evaluating exoskeletons with industrial applications. ERGONOMICS 2022; 65:276-295. [PMID: 34415823 DOI: 10.1080/00140139.2021.1970823] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 08/12/2021] [Indexed: 06/13/2023]
Abstract
Industrial exoskeletons are globally developed, explored, and increasingly implemented in industrial workplaces. Multiple technical, physical, and psychological aspects should be assessed prior to their daily application in various occupational environments. The methodology for evaluating these aspects is not standardised and differs in terms of focussed research objectives, used types of analyses, applied testing procedures, and use cases. The aim of this paper is to provide a matrix comparing the prevalence of different types of analyses combined with their respective research objective(s). A systematic review in the database 'Web of Science' identified 74 studies, mainly in laboratory settings, with a focus on short-term effects as well as with male-dominated samples being low representative for industrial workforces. The conducted evaluation methodologies are further discussed and compared in terms of testing procedure, sample, and research objectives. Finally, relevant aspects for prospectively evaluating industrial exoskeletons in a more harmonised and comprehensive way are suggested. Practitioner summary: Industrial exoskeletons are still inconsistently and insufficiently evaluated in scientific studies, which might hamper the comparability of systems, threaten the human health, and block an iterative system optimisation. Thus, a comprehensive evaluation methodology is needed with harmonised and multicriteria types of analyses.
Collapse
Affiliation(s)
- Niclas Hoffmann
- Department of Production Technologies, Institute of Mechatronics, University of Innsbruck, Innsbruck, Austria
- Laboratory of Manufacturing Technology, Helmut-Schmidt-University/University of the Federal Armed Forces Hamburg, Hamburg, Germany
| | - Gilbert Prokop
- Department of Production Technologies, Institute of Mechatronics, University of Innsbruck, Innsbruck, Austria
| | - Robert Weidner
- Department of Production Technologies, Institute of Mechatronics, University of Innsbruck, Innsbruck, Austria
- Laboratory of Manufacturing Technology, Helmut-Schmidt-University/University of the Federal Armed Forces Hamburg, Hamburg, Germany
| |
Collapse
|
11
|
A Review on the Rehabilitation Exoskeletons for the Lower Limbs of the Elderly and the Disabled. ELECTRONICS 2022. [DOI: 10.3390/electronics11030388] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Research on the lower limb exoskeleton for rehabilitation have developed rapidly to meet the need of the aging population. The rehabilitation exoskeleton system is a wearable man–machine integrated mechanical device. In recent years, the vigorous development of exoskeletal technology has brought new ideas to the rehabilitation and medical treatment of patients with motion dysfunction, which is expected to help such people complete their daily physiological activities or even reshape their motion function. The rehabilitation exoskeletons conduct assistance based on detecting intention, control algorithm, and high-performance actuators. In this paper, we review rehabilitation exoskeletons from the aspects of the overall design, driving unit, intention perception, compliant control, and efficiency validation. We discussed the complexity and coupling of the man–machine integration system, and we hope to provide a guideline when designing a rehabilitation exoskeleton system for the lower limbs of elderly and disabled patients.
Collapse
|
12
|
De Bock S, Ghillebert J, Govaerts R, Tassignon B, Rodriguez-Guerrero C, Crea S, Veneman J, Geeroms J, Meeusen R, De Pauw K. Benchmarking occupational exoskeletons: An evidence mapping systematic review. APPLIED ERGONOMICS 2022; 98:103582. [PMID: 34600307 DOI: 10.1016/j.apergo.2021.103582] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 09/03/2021] [Accepted: 09/07/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVES To provide an overview of protocols assessing the effect of occupational exoskeletons on users and to formulate recommendations towards a literature-based assessment framework to benchmark the effect of occupational exoskeletons on the user. METHODS PubMed (MEDLINE), Web of Science database and Scopus were searched (March 2, 2021). Studies were included if they investigated the effect of one or more occupational exoskeletons on the user. RESULTS In total, 139 eligible studies were identified, encompassing 33, 25 and 18 unique back, shoulder and other exoskeletons, respectively. Device validation was most frequently conducted using controlled tasks while collecting muscle activity and biomechanical data. As the exoskeleton concept matures, tasks became more applied and the experimental design more representative. With that change towards realistic testing environments came a trade-off with experimental control, and user experience data became more valuable. DISCUSSION This evidence mapping systematic review reveals that the assessment of occupational exoskeletons is a dynamic process, and provides literature-based assessment recommendations. The homogeneity and repeatability of future exoskeleton assessment experiments will increase following these recommendations. The current review recognises the value of variability in evaluation protocols in order to obtain an overall overview of the effect of exoskeletons on the users, but the presented framework strives to facilitate benchmarking the effect of occupational exoskeletons on the users across this variety of assessment protocols.
Collapse
Affiliation(s)
- Sander De Bock
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium; Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium.
| | - Jo Ghillebert
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium; Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium
| | - Renée Govaerts
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium; Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium
| | - Bruno Tassignon
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium
| | - Carlos Rodriguez-Guerrero
- Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium; Department of Mechanical Engineering, Faculty of Applied Sciences, Vrije Universiteit Brussel and Flanders Make, 1050, Brussels, Belgium; COST (European Cooperation in Science and Technology) Action 16116, Wearable Robots for Augmentation, Assistance or Substitution of Human Motor Functions, Belgium
| | - Simona Crea
- COST (European Cooperation in Science and Technology) Action 16116, Wearable Robots for Augmentation, Assistance or Substitution of Human Motor Functions, Belgium; The BioRobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Italy; IRCCS Fondazione Don Carlo Gnocchi, Florence, Italy
| | - Jan Veneman
- COST (European Cooperation in Science and Technology) Action 16116, Wearable Robots for Augmentation, Assistance or Substitution of Human Motor Functions, Belgium; Hocoma AG, Volketswil, Switzerland
| | - Joost Geeroms
- Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium; Department of Mechanical Engineering, Faculty of Applied Sciences, Vrije Universiteit Brussel and Flanders Make, 1050, Brussels, Belgium
| | - Romain Meeusen
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium; Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium; Strategic Research Program 'Exercise and the Brain in Health and Disease: The Added Value of Human-Centered Robotics', Vrije Universiteit Brussel, 1050, Brussels, Belgium
| | - Kevin De Pauw
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium; Brussels Human Robotic Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium; Strategic Research Program 'Exercise and the Brain in Health and Disease: The Added Value of Human-Centered Robotics', Vrije Universiteit Brussel, 1050, Brussels, Belgium
| |
Collapse
|
13
|
Pinto-Fernandez D, Torricelli D, Sanchez-Villamanan MDC, Aller F, Mombaur K, Conti R, Vitiello N, Moreno JC, Pons JL. Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review. IEEE Trans Neural Syst Rehabil Eng 2021; 28:1573-1583. [PMID: 32634096 DOI: 10.1109/tnsre.2020.2989481] [Citation(s) in RCA: 54] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Benchmarks have long been used to verify and compare the readiness level of different technologies in many application domains. In the field of wearable robots, the lack of a recognized benchmarking methodology is one important impediment that may hamper the efficient translation of research prototypes into actual products. At the same time, an exponentially growing number of research studies are addressing the problem of quantifying the performance of robotic exoskeletons, resulting in a rich and highly heterogeneous picture of methods, variables and protocols. This review aims to organize this information, and identify the most promising performance indicators that can be converted into practical benchmarks. We focus our analysis on lower limb functions, including a wide spectrum of motor skills and performance indicators. We found that, in general, the evaluation of lower limb exoskeletons is still largely focused on straight walking, with poor coverage of most of the basic motor skills that make up the activities of daily life. Our analysis also reveals a clear bias towards generic kinematics and kinetic indicators, in spite of the metrics of human-robot interaction. Based on these results, we identify and discuss a number of promising research directions that may help the community to attain a comprehensive benchmarking methodology for robot-assisted locomotion more efficiently.
Collapse
|
14
|
Development of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review. Int J Soc Robot 2020. [DOI: 10.1007/s12369-020-00662-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
15
|
Sanchez-Villamañan MDC, Gonzalez-Vargas J, Torricelli D, Moreno JC, Pons JL. Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles. J Neuroeng Rehabil 2019; 16:55. [PMID: 31072370 PMCID: PMC6506961 DOI: 10.1186/s12984-019-0517-9] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Accepted: 03/26/2019] [Indexed: 12/04/2022] Open
Abstract
Exoskeleton technology has made significant advances during the last decade, resulting in a considerable variety of solutions for gait assistance and rehabilitation. The mechanical design of these devices is a crucial aspect that affects the efficiency and effectiveness of their interaction with the user. Recent developments have pointed towards compliant mechanisms and structures, due to their promising potential in terms of adaptability, safety, efficiency, and comfort. However, there still remain challenges to be solved before compliant lower limb exoskeletons can be deployed in real scenarios. In this review, we analysed 52 lower limb wearable exoskeletons, focusing on three main aspects of compliance: actuation, structure, and interface attachment components. We highlighted the drawbacks and advantages of the different solutions, and suggested a number of promising research lines. We also created and made available a set of data sheets that contain the technical characteristics of the reviewed devices, with the aim of providing researchers and end-users with an updated overview on the existing solutions.
Collapse
Affiliation(s)
| | - Jose Gonzalez-Vargas
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Avda Doctor Arce, 37, E-28002 Madrid, Spain
| | - Diego Torricelli
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Avda Doctor Arce, 37, E-28002 Madrid, Spain
| | - Juan C. Moreno
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Avda Doctor Arce, 37, E-28002 Madrid, Spain
| | - Jose L. Pons
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Avda Doctor Arce, 37, E-28002 Madrid, Spain
| |
Collapse
|
16
|
Gordon DFN, Henderson G, Vijayakumar S. Effectively Quantifying the Performance of Lower-Limb Exoskeletons Over a Range of Walking Conditions. Front Robot AI 2018; 5:61. [PMID: 33644121 PMCID: PMC7904313 DOI: 10.3389/frobt.2018.00061] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 05/07/2018] [Indexed: 11/13/2022] Open
Abstract
Exoskeletons and other wearable robotic devices have a wide range of potential applications, including assisting patients with walking pathologies, acting as tools for rehabilitation, and enhancing the capabilities of healthy humans. However, applying these devices effectively in a real-world setting can be challenging, as the optimal design features and control commands for an exoskeleton are highly dependent on the current user, task and environment. Consequently, robust metrics and methods for quantifying exoskeleton performance are required. This work presents an analysis of walking data collected for healthy subjects walking with an active pelvis exoskeleton over three assistance scenarios and five walking contexts. Spatial and temporal, kinematic, kinetic and other novel dynamic gait metrics were compared to identify which metrics exhibit desirable invariance properties, and so are good candidates for use as a stability metric over varying walking conditions. Additionally, using a model-based approach, the average metabolic power consumption was calculated for a subset of muscles crossing the hip, knee and ankle joints, and used to analyse how the energy-reducing properties of an exoskeleton are affected by changes in walking context. The results demonstrated that medio-lateral centre of pressure displacement and medio-lateral margin of stability exhibit strong invariance to changes in walking conditions. This suggests that these dynamic gait metrics are optimised in human gait and are potentially suitable metrics for optimising in an exoskeleton control paradigm. The effectiveness of the exoskeleton at reducing human energy expenditure was observed to increase when walking on an incline, where muscles aiding in hip flexion were assisted, but decrease when walking at a slow speed. These results underline the need for adaptive control algorithms for exoskeletons if they are to be used in varied environments.
Collapse
Affiliation(s)
- Daniel F. N. Gordon
- Institute of Perception, Action, and Behaviour, School of Informatics, University of Edinburgh, Edinburgh, United Kingdom
| | - Graham Henderson
- Institute of Perception, Action, and Behaviour, School of Informatics, University of Edinburgh, Edinburgh, United Kingdom
| | - Sethu Vijayakumar
- Institute of Perception, Action, and Behaviour, School of Informatics, University of Edinburgh, Edinburgh, United Kingdom
| |
Collapse
|
17
|
d'Elia N, Vanetti F, Cempini M, Pasquini G, Parri A, Rabuffetti M, Ferrarin M, Lova RM, Vitiello N. Erratum to: Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots. J Neuroeng Rehabil 2017; 14:51. [PMID: 28583163 PMCID: PMC5458473 DOI: 10.1186/s12984-017-0262-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Accepted: 05/23/2017] [Indexed: 11/26/2022] Open
Affiliation(s)
- Nicolò d'Elia
- The BioRobotics Institute, Scuola Superiore Sant'Anna, viale Rinaldo Piaggio, 34, 56025 Pontedera, Pisa, Italy. .,Fondazione Don Carlo Gnocchi IRCCS, Florence, Italy.
| | | | - Marco Cempini
- The BioRobotics Institute, Scuola Superiore Sant'Anna, viale Rinaldo Piaggio, 34, 56025 Pontedera, Pisa, Italy
| | | | - Andrea Parri
- The BioRobotics Institute, Scuola Superiore Sant'Anna, viale Rinaldo Piaggio, 34, 56025 Pontedera, Pisa, Italy
| | | | | | | | - Nicola Vitiello
- The BioRobotics Institute, Scuola Superiore Sant'Anna, viale Rinaldo Piaggio, 34, 56025 Pontedera, Pisa, Italy.,Fondazione Don Carlo Gnocchi IRCCS, Florence, Italy
| |
Collapse
|