Katayama H, Kobata T, Kitaoka M, Takahashi S, Shibata T. Impact of MLC error on dose distribution in SRS treatment of single-isocenter multiple brain metastases: comparison between DCAT and VMAT techniques. Rep Pract Oncol Radiother 2024; 29:531-543. [PMID: 39759551 PMCID: PMC11698555 DOI: 10.5603/rpor.102616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 09/04/2024] [Indexed: 01/07/2025] Open
Abstract
Background Dynamic conformal arc therapy (DCAT) and volumetric modulated arc therapy (VMAT) can achieve near equal plan quality in single-isocenter multiple target stereotactic radiosurgery (SRS) for brain metastases. This study aimed to investigate the impact of multi-leaf collimator (MLC) errors during beam delivery on the dose distribution for each technique. Materials and methods A 10-mm diameter delineation of the three targets was employed on the computed tomography images of a head phantom, and the reference plans were created using the DCAT and VMAT. We simulated the systematic opened and closed MLC errors. 10 MLC error plans with different magnitudes of errors were created in each technique. We investigated the relationship between the magnitude of MLC errors and the change in dose-volume histogram parameters of the targets and normal brain tissue. Results The percentage change in the D98% (Gy) and D0.1% (Gy) of the target per millimeter of the MLC errors were 13.3% and 2.7% for the DCAT and 15.3% and 9.3% for the VMAT, respectively. The fluctuations of the maximum dose were very small for the DCAT compared to the VMAT. Changes in the V12Gy (cc) of the normal brain tissue were 47.1%/mm and 53.2%/mm for the DCAT and VMAT, respectively, which are comparable changes for both techniques. Conclusions Although the impact of MLC errors on the target coverage and the normal brain tissue is comparable for both techniques, the internal dose of the targets generated by the DCAT technique is robust to the MLC errors.
Collapse
Affiliation(s)
- Hiroki Katayama
- Department of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan
| | - Takuya Kobata
- Department of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan
| | - Motonori Kitaoka
- Department of Clinical Radiology, Kagawa University Hospital, Kagawa, Japan
| | - Shigeo Takahashi
- Department of Radiation Oncology, Kagawa University Hospital, Kagawa, Japan
| | - Toru Shibata
- Department of Radiation Oncology, Kagawa University Hospital, Kagawa, Japan
| |
Collapse
|
2
|
Takizawa T, Tanabe S, Nakano H, Utsunomiya S, Maruyama K, Kaidu M, Ishikawa H, Onda K. Selection criteria for circular collimator- vs. Multileaf collimator-based plans in robotic stereotactic radiotherapy for brain metastases and benign intracranial disease: Impact of target size, shape complexity, and proximity to at-risk organs. Phys Med 2024; 127:104852. [PMID: 39488129 DOI: 10.1016/j.ejmp.2024.104852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 10/22/2024] [Accepted: 10/25/2024] [Indexed: 11/04/2024] Open
Abstract
PURPOSE This study aimed to determine the selection criteria for circular collimator (CC)- and multileaf collimator (MLC)-based stereotactic radiosurgery (SRS)/stereotactic radiotherapy (SRT) plans for brain metastases (BM) and benign intracranial disease (BID) in terms of geometric parameters using CyberKnife (CK). METHODS Forty-eight and eighty-five patients with BM and BID, respectively, were included. Two plans using CC and MLC were created for each case. Six dosimetric parameters and mathematical scores (MS) were extracted from each plan to assess plan quality. Two geometric parameters in BM-equivalent radius (rGTV) and sphericity index (SI) of the gross tumor volume-and three in BID-rGTV, SI, and the distance between the GTV and organ at risk (dOAR)-were calculated. Their effect on the superiority of CC- or MLC-based plans in terms of dosimetric parameters and MS was evaluated using multiple regression analysis. RESULTS The rGTV was associated with improved dosimetric parameters of MLC-based plans, especially the GTV conformity in BM and BID cases (β: 0.70 and 0.51) and the OAR sparing in BM cases (β: 0.82), where β represents the regression coefficient. Based on the MS, where the weights for the GTV coverage and OAR sparing were equal, the thresholds at which the MLC-based plans become comparable or superior to the CC-based plans in BM and BID were rGTV > 7.6 and >17.5 mm, respectively. Meanwhile, SI and dOAR were weakly correlated (β ≤ 0.30). CONCLUSIONS In SRS/SRT plans for BM and BID cases using CyberKnife, geometric parameters, especially rGTV, must be considered when selecting CC or MLC.
Collapse
Affiliation(s)
- Takeshi Takizawa
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata 950-1101, Japan; Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata 951-8510, Japan.
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata 951-8510, Japan
| | - Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata 951-8510, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata 951-8518, Japan
| | - Katsuya Maruyama
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata 950-1101, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata 951-8510, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata 951-8510, Japan
| | - Kiyoshi Onda
- Department of Neurosurgery, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata 950-1101, Japan
| |
Collapse
|
3
|
Duan W, Wu H, Zhu Y, Zhao G, Zhang C, Jiang J, Fan Z, Wang Z, Wang R. Dosimetric comparison of gamma knife and linear accelerator (VMAT and IMRT) plans of SBRT of Lung tumours. Sci Rep 2024; 14:22949. [PMID: 39363094 PMCID: PMC11450005 DOI: 10.1038/s41598-024-74397-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Accepted: 09/25/2024] [Indexed: 10/05/2024] Open
Abstract
This study evaluates dosimetric differences in Stereotactic Body Radiation Therapy (SBRT) for lung tumors using plans of Gamma Knife, and Volumetric Modulated Arc Therapy (VMAT), Intensity-Modulated Radiation Therapy (IMRT) plans based on Linear Accelerator, aiming to inform the reader of appropriate treatment strategy selection. Ten patients with 23 lung tumor lesions treated with SBRT at Zhongshan Hospital of Dalian University were analyzed. Plans of Gamma Knife, and VMAT, IMRT plans based on Linear Accelerator were created for each lesion, totaling 18 plans per type. Lesions were treated with 30-50 Gy in 5-10 fractions. Dosimetric parameters, including gradient index (GI), heterogeneity index (HI), conformity index (CI), and doses to the plan target volumes (PTVs), the gross tumor volumes (GTVs) and organs at risk (OARs) were compared. Plans of Gamma Knife showed superior HI and GI, higher PTV and GTV doses, and reduced doses to the ipsilateral and contralateral lungs, esophagus, spinal cord, and heart compared to VMAT and IMRT plans (p < 0.05). However, Plans of Gamma Knife required longer delivery times. When comparing VMAT and IMRT plans, VMAT plans had shorter delivery times than IMRT plans, but required more monitor units (MUs). Additionally, IMRT plans delivered a lower mean dose to the ipsilateral lung compared to VMAT plans. Gamma Knife SBRT plans achieves steeper dose falloff and minimizes radiation to normal lung tissue compared to VMAT and IMRT plans, but with longer delivery times. VMAT and IMRT plans displayed similar dose distributions for lung SBRT.
Collapse
Affiliation(s)
- Wenyue Duan
- Department of Radiotherapy, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China
| | - Huajian Wu
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China
| | - Yanmei Zhu
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China
| | - Genghao Zhao
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China
| | - Chuanhao Zhang
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- Graduate School of Dalian Medical University, Dalian, P. R. China
| | - Jianing Jiang
- Department of Radiotherapy, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China
| | - Zhijun Fan
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China
| | - Zhe Wang
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China.
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China.
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China.
| | - Ruoyu Wang
- Department of Medical Oncology, Affiliated Zhongshan Hospital of Dalian University, Dalian, P. R. China.
- The Key Laboratory of Biomarker High Throughput Screening and Target Translation of Breast and Gastrointestinal Tumor, Dalian University, Dalian, P. R. China.
- The Key Laboratory of Radioactive Particles and Thermal Precision Therapy, Dalian University, Dalian, P. R. China.
| |
Collapse
|
4
|
Mukwada G, Chamunyonga C, Rowshanfarzad P, Gill S, Ebert MA. Insights into the dosimetric and geometric characteristics of stereotactic radiosurgery for multiple brain metastases: A systematic review. PLoS One 2024; 19:e0307088. [PMID: 39121064 PMCID: PMC11315342 DOI: 10.1371/journal.pone.0307088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2024] [Accepted: 06/30/2024] [Indexed: 08/11/2024] Open
Abstract
BACKGROUND GammaKnife (GK) and CyberKnife (CK) have been the mainstay stereotactic radiosurgery (SRS) solution for multiple brain metastases (MBM) for several years. Recent technological advancement has seen an increase in single-isocentre C-arm linac-based SRS. This systematic review focuses on dosimetric and geometric insights into contemporary MBM SRS and thereby establish if linac-based SRS has matured to match the mainstay SRS delivery systems. METHODS The PubMed, Web of Science and Scopus databases were interrogated which yielded 891 relevant articles that narrowed to 20 articles after removing duplicates and applying the inclusion and exclusion criteria. Primary studies which reported the use of SRS for treatment of MBM SRS and reported the technical aspects including dosimetry were included. The review was limited to English language publications from January 2015 to August 2023. Only full-length papers were included in the final analysis. Opinion papers, commentary pieces, letters to the editor, abstracts, conference proceedings and editorials were excluded. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed. The reporting of conformity indices (CI) and gradient indices, V12Gy, monitor units and the impact of translational and rotational shifts were extracted and analysed. RESULTS The single-isocentre technique for MBM dominated recent SRS studies and the most studied delivery platforms were Varian. The C-arm linac-based SRS plan quality and normal brain tissue sparing was comparable to GK and CK and in some cases better. The most used nominal beam energy was 6FFF, and optimised couch and collimator angles could reduce mean normal brain dose by 11.3%. Reduction in volume of the healthy brain receiving a certain dose was dependent on the number and size of the metastases and the relative geometric location. GK and CK required 4.5-8.4 times treatment time compared with linac-based SRS. Rotational shifts caused larger changes in CI in C-arm linac-based single-isocentre SRS. CONCLUSION C-arm linac-based SRS produced comparable MBM plan quality and the delivery is notably shorter compared to GK and CK SRS.
Collapse
Affiliation(s)
- Godfrey Mukwada
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, Western Australia, Australia
- School of Physics, Mathematics and Computing, University of Western Australia, Crawley, Western Australia, Australia
| | - Crispen Chamunyonga
- School of Clinical Sciences, Discipline of Radiation Therapy, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics and Computing, University of Western Australia, Crawley, Western Australia, Australia
- Centre for Advanced Technologies in Cancer Research (CATCR), Perth, Western Australia, Australia
| | - Suki Gill
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, Western Australia, Australia
- School of Physics, Mathematics and Computing, University of Western Australia, Crawley, Western Australia, Australia
| | - Martin A. Ebert
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Hospital Ave, Nedlands, Western Australia, Australia
- School of Physics, Mathematics and Computing, University of Western Australia, Crawley, Western Australia, Australia
- Centre for Advanced Technologies in Cancer Research (CATCR), Perth, Western Australia, Australia
- School of Medicine and Population Health, University of Wisconsin, Madison, Wisconsin, United States of America
| |
Collapse
|
5
|
Sun X, Guan F, Yun Q, Jennings M, Biggs S, Wang Z, Wang W, Zhang T, Shi M, Zhao L. Impact of setup errors on the robustness of linac-based single-isocenter coplanar and non-coplanar VMAT plans for multiple brain metastases. J Appl Clin Med Phys 2024; 25:e14317. [PMID: 38439583 PMCID: PMC11244668 DOI: 10.1002/acm2.14317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 12/21/2023] [Accepted: 02/13/2024] [Indexed: 03/06/2024] Open
Abstract
PURPOSE Patient setup errors have been a primary concern impacting the dose delivery accuracy in radiation therapy. A robust treatment plan might mitigate the effects of patient setup errors. In this reported study, we aimed to evaluate the impact of translational and rotational errors on the robustness of linac-based, single-isocenter, coplanar, and non-coplanar volumetric modulated arc therapy treatment plans for multiple brain metastases. METHODS Fifteen patients were retrospectively selected for this study with a combined total of 49 gross tumor volumes (GTVs). Single-isocenter coplanar and non-coplanar plans were generated first with a prescribed dose of 40 Gy in 5 fractions or 42 Gy in 7 fractions to cover 95% of planning target volume (PTV). Next, four setup errors (+1 and +2 mm translation, and +1° and +2° rotation) were applied individually to generate modified plans. Different plan quality evaluation metrics were compared between coplanar and non-coplanar plans. 3D gamma analysis (3%/2 mm) was performed to compare the modified plans (+2 mm and +2° only) and the original plans. Paired t-test was conducted for statistical analysis. RESULTS After applying setup errors, variations of all plan evaluation metrics were similar (p > 0.05). The worst case for V100% to GTV was 92.07% ± 6.13% in the case of +2 mm translational error. 3D gamma pass rates were > 90% for both coplanar (+2 mm and +2°) and the +2 mm non-coplanar groups but was 87.40% ± 6.89% for the +2° non-coplanar group. CONCLUSION Translational errors have a greater impact on PTV and GTV dose coverage for both planning methods. Rotational errors have a greater negative impact on gamma pass rates of non-coplanar plans. Plan evaluation metrics after applying setup errors showed that both coplanar and non-coplanar plans were robust and clinically acceptable.
Collapse
Affiliation(s)
- Xiaohuan Sun
- Department of Radiation Oncology, Xijing Hospital, Air Force Medical University, Xi'an, China
| | - Fada Guan
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut, USA
| | - Qinghui Yun
- Department of Equipment, Xijing Hospital, Air Force Medical University, Xi'an, China
| | - Matthew Jennings
- Department of Medical Physics, Townsville University Hospital, Douglas, Queensland, Australia
| | - Simon Biggs
- Radiotherapy AI Pty Ltd, Wagga Wagga, Australia
| | - Zhongfei Wang
- Department of Radiation Oncology, Xijing Hospital, Air Force Medical University, Xi'an, China
| | - Wei Wang
- Department of Radiation Oncology, Xijing Hospital, Air Force Medical University, Xi'an, China
| | - Te Zhang
- Department of Radiation Oncology, Xijing Hospital, Air Force Medical University, Xi'an, China
| | - Mei Shi
- Department of Radiation Oncology, Xijing Hospital, Air Force Medical University, Xi'an, China
| | - Lina Zhao
- Department of Radiation Oncology, Xijing Hospital, Air Force Medical University, Xi'an, China
| |
Collapse
|
6
|
Oliveira AM, Akkerman HB, Braccini S, van Breemen AJJM, Gelinck GH, Heracleous N, Leidner J, Murtas F, Peeters B, Silari M. A high-resolution large-area detector for quality assurance in radiotherapy. Sci Rep 2024; 14:10637. [PMID: 38724569 PMCID: PMC11082155 DOI: 10.1038/s41598-024-61095-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/30/2024] [Indexed: 05/12/2024] Open
Abstract
Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.
Collapse
Affiliation(s)
- Andreia Maia Oliveira
- CERN - Occupational Health & Safety and Environmental Protection Unit, Radiation Protection Group, 1211, Geneva 23, Switzerland.
- Laboratory for High Energy Physics (LHEP), Albert Einstein Center for Fundamental Physics (AEC), University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland.
- EBG MedAustron GmbH, Marie Curie-Straße 5, 2700, Wiener Neustadt, Austria.
| | - Hylke B Akkerman
- Holst Centre/TNO, High Tech, Campus 31, 5656 AE, Eindhoven, The Netherlands
| | - Saverio Braccini
- Laboratory for High Energy Physics (LHEP), Albert Einstein Center for Fundamental Physics (AEC), University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| | | | - Gerwin H Gelinck
- Holst Centre/TNO, High Tech, Campus 31, 5656 AE, Eindhoven, The Netherlands
| | - Natalie Heracleous
- CERN - Occupational Health & Safety and Environmental Protection Unit, Radiation Protection Group, 1211, Geneva 23, Switzerland
- Institute of Radiation Physics, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland
| | - Johannes Leidner
- CERN - Occupational Health & Safety and Environmental Protection Unit, Radiation Protection Group, 1211, Geneva 23, Switzerland
- Medidee Services SA, Chemin de Rovéréaz 5, 1012, Lausanne, Switzerland
| | - Fabrizio Murtas
- CERN - Occupational Health & Safety and Environmental Protection Unit, Radiation Protection Group, 1211, Geneva 23, Switzerland
- INFN-LNF, 00044, Frascati, Italy
| | - Bart Peeters
- Holst Centre/TNO, High Tech, Campus 31, 5656 AE, Eindhoven, The Netherlands
| | - Marco Silari
- CERN - Occupational Health & Safety and Environmental Protection Unit, Radiation Protection Group, 1211, Geneva 23, Switzerland
| |
Collapse
|
7
|
Oshiro Y, Kato Y, Mizumoto M, Sakurai H. The Impact of Multileaf Collimator Size on Single Isocenter Dynamic Conformal Arcs-Based Radiosurgery for Brain Metastases. Cureus 2024; 16:e58816. [PMID: 38784358 PMCID: PMC11113089 DOI: 10.7759/cureus.58816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/23/2024] [Indexed: 05/25/2024] Open
Abstract
PURPOSE To compare the plan quality of stereotactic radiosurgery (SRS) between 2.5-mm and 5-mm multileaf collimator (MLC) and investigate the factors' influence on the differences by MLC size. METHODS Seventy-six treatment plans including 145 targets calculated with a single isocenter multiple noncoplanar dynamic conformal arc (DCA) technique using automatic multiple brain metastases (MBM) treatment planning system. Conformity index (CI), gradient index (GI), lesion underdosage volume factor (LUF), healthy tissue overdose volume factor (HTOF), geometric conformity index (g), and mean dose to normal organs were compared between 2.5-mm and 5-mm MLC. Then the factors that influenced the differences of these parameters were investigated. The impact of target size was also investigated for CI and GI values of individual targets (n=145), and differences between 2.5-mm and 5-mm MLC were analyzed. RESULTS All parameters except for LUF were significantly better in plans with 2.5 mm MLC. Target size was a significant factor for difference in HTOF, and distance between targets was a significant factor for difference in brain dose and GI. Among 145 metastases, the average inverse CI was 1.35 and 1.47 with 2.5-mm and 5-mm MLC, respectively (p<0.001). The average GI was 3.21 and 3.53, respectively (p<0.001). For individual targets, target size was a significant factor in CI and GI both with 2.5-mm and 5-mm MLC (p-value: <0.001, each). CI and GI were significantly better with 2.5-mm than 5-mm MLC. CI was almost >0.67 except for ≤5mm targets with 5-mm MLC. Also, GI was almost smaller than 3.0 for >10 mm targets both with 2.5-mm and 5-mm MLC. CONCLUSIONS MBM with 5-mm MLC was almost fine. However, it may be better to use a conservative margin for larger metastases. It may also be better to avoid SRS with 5-mm MLC for patients with ≤5 mm target size.
Collapse
Affiliation(s)
- Yoshiko Oshiro
- Radiation Oncology, Tsukuba Medical Center Hospital, Tsukuba, JPN
| | - Yuichi Kato
- Radiation Oncology, Tsukuba Medical Center Hospital, Tsukuba, JPN
| | - Masashi Mizumoto
- Radiation Oncology, University of Tsukuba Hospital, Tsukuba, JPN
| | - Hideyuki Sakurai
- Radiation Oncology, University of Tsukuba Hospital, Tsukuba, JPN
| |
Collapse
|
8
|
Chambrelant I, Jarnet D, Le Fèvre C, Kuntz L, Jacob J, Jenny C, Noël G. Comparative study of dynamic conformal arc therapy and volumetric modulated arc therapy for treating single brain metastases: A retrospective analysis of dosimetric and clinical outcomes. Phys Imaging Radiat Oncol 2024; 30:100591. [PMID: 38832123 PMCID: PMC11145388 DOI: 10.1016/j.phro.2024.100591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 05/16/2024] [Accepted: 05/17/2024] [Indexed: 06/05/2024] Open
Abstract
Background and purpose Stereotactic radiation therapy (SRT) is commonly used to treat brain metastases (BMs). This retrospective study compared two SRT techniques, dynamic conformal arc therapy (DCAT) and volumetric modulated arc therapy (VMAT), for single BM treatments. Material and methods Data of patients treated between January 2010 and June 2020 were considered. Patients with multiple BMs, resected BMs, reirradiation, whole-brain radiation therapy and brainstem metastases were excluded. We focused our analysis on 97 patients who received 23.1 Gy in three fractions. Acute toxicities and follow-up outcomes were recorded. Dosimetric data were analyzed in two subgroups (PTV ≤ 10 cc and PTV > 10 cc). Results DCAT and VMAT were used in 70 (72.2 %) and 27 (27.8 %) patients, respectively. Acute toxicities were not significantly different between groups (p = 0.259), and no difference was detected in the incidence rate of radionecrosis, local recurrence and cerebral recurrence (p > 0.999, p > 0.999 and p = 0.682, respectively). PTV coverage was better with DCAT for small volumes (PTV ≤ 10 cc). Mean conformity index (CI) was significantly higher with VMAT and mean gradient index (GI) was significantly lower with DCAT whatever volume subgroups (p < 0.001). DCAT had more heterogeneous plans and VMAT required more monitor units. DCAT resulted in reduced low and intermediate doses, whereas VMAT led to decreased high doses. Conclusion DCAT and VMAT are two effective and safe SRT techniques for BMs treatment. In the era of re-irradiation, it is important to reduce the doses delivered to healthy tissues. Further prospective studies are needed to validate these findings.
Collapse
Affiliation(s)
- Isabelle Chambrelant
- Department of Radiation Oncology, Institut de Cancérologie Strasbourg Europe (ICANS), UNICANCER, Paul Strauss Comprehensive Cancer Center, 67200 Strasbourg, France
| | - Delphine Jarnet
- Department of Medical Physics, Institut de Cancérologie Strasbourg Europe (ICANS), UNICANCER, Paul Strauss Comprehensive Cancer Center, 67200 Strasbourg, France
| | - Clara Le Fèvre
- Department of Radiation Oncology, Institut de Cancérologie Strasbourg Europe (ICANS), UNICANCER, Paul Strauss Comprehensive Cancer Center, 67200 Strasbourg, France
| | - Laure Kuntz
- Department of Radiation Oncology, Institut de Cancérologie Strasbourg Europe (ICANS), UNICANCER, Paul Strauss Comprehensive Cancer Center, 67200 Strasbourg, France
| | - Julian Jacob
- Department of Radiation Oncology, AP-HP. Sorbonne Université, Hôpitaux Universitaires Pitié-Salpêtrière, 47-83 Bd de l’Hôpital, 75651 Paris Cedex 13, France
| | - Catherine Jenny
- Department of Medical Physics, AP-HP. Sorbonne Université, Hôpitaux Universitaires Pitié Salpêtrière, 47-83 Bd de l’Hôpital, 75651 Paris Cedex 13, France
| | - Georges Noël
- Department of Radiation Oncology, Institut de Cancérologie Strasbourg Europe (ICANS), UNICANCER, Paul Strauss Comprehensive Cancer Center, 67200 Strasbourg, France
| |
Collapse
|
9
|
Oshiro Y, Mizumoto M, Kato Y, Tsuchida Y, Tsuboi K, Sakae T, Sakurai H. Single isocenter dynamic conformal arcs-based radiosurgery for brain metastases: Dosimetric comparison with Cyberknife and clinical investigation. Tech Innov Patient Support Radiat Oncol 2024; 29:100235. [PMID: 38299171 PMCID: PMC10827586 DOI: 10.1016/j.tipsro.2024.100235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 12/14/2023] [Accepted: 01/09/2024] [Indexed: 02/02/2024] Open
Abstract
Purpose To compare the dosimetric quality of automatic multiple brain metastases planning (MBM) with that of Cyberknife (CK) based on the clinical tumor condition, such as the tumor number, size, and location. Methods 76 treatment plans for 46 patients treated with CK were recalculated with the MBM treatment planning system. Conformity index (CI), homogeneity index (HI), gradient index (GI), lesion underdosage volume factor (LUF), healthy tissue overdose volume factor (HTOF), geometric conformity index (g) and mean dose to normal organs were compared between CK and MBM for tumor number, size, shape and distance from the brainstem or chiasm. Results The results showed that the mean brain dose was significantly smaller in MBM than CK. CI did not differ between MBM and CK; however, HI was significantly more ideal in CK (p = 0.000), and GI was significantly smaller in MBM (P = 0.000). LUF was larger in CK (p = 0.000) and HTOF and g was larger in MBM (p = 0.003, and 0.012). For single metastases, CK had significantly better HTOF (p = 0.000) and g (p = 0.002), but there were no differences for multiple tumors. Brain dose in MBM was significantly lower and CI was higher for tumors < 30 mm (p = 0.000 and 0.000), whereas HTOF and g for tumors < 10 mm were significantly smaller in CK (p = 0.041 and p = 0.016). Among oval tumors, brain dose, GI and LUF were smaller in MBM, but HTOF and g were smaller in CK. There were no particular trends for tumors close to the brainstem, but HTOF tended to be smaller in CK (0.03 vs. 0.29, p = 0.068) for tumors inside the brainstem. Conclusions MBM can reduce the brain dose while achieving a dose distribution quality equivalent to that with CK.
Collapse
Affiliation(s)
- Yoshiko Oshiro
- Department of Radiation Oncology, Tsukuba Medical Center Hospital, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| | - Masashi Mizumoto
- Department of Neurosurgery, Tsukuba Central Hospital, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
- Department of Radiation Therapy, University of Tsukuba, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| | - Yuichi Kato
- Department of Radiation Oncology, Tsukuba Medical Center Hospital, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| | - Yukihiro Tsuchida
- Department of Neurosurgery, Tsukuba Central Hospital, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| | - Koji Tsuboi
- Department of Neurosurgery, Tsukuba Central Hospital, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| | - Takeji Sakae
- Department of Radiation Therapy, University of Tsukuba, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| | - Hideyuki Sakurai
- Department of Radiation Therapy, University of Tsukuba, Amakubo 1-3-1, Tsukuba, Ibaraki, 305-8558, Japan
| |
Collapse
|
10
|
Hiscoke K, Leong A, Hogan AM, Cowley I. Plan quality assessment of modern radiosurgery technologies in the treatment of multiple brain metastases. Biomed Phys Eng Express 2024; 10:025021. [PMID: 38262047 DOI: 10.1088/2057-1976/ad218f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 01/23/2024] [Indexed: 01/25/2024]
Abstract
Stereotactic radiosurgery (SRS) of multiple brain metastases has evolved over the last 40 years allowing centres to treat an increasing number of brain metastases in a single treatment fraction. HyperArcTMplanning optimisation technique is one such development that streamlines the treatment of multiple metastases with a single isocentre. Several studies have investigated the plan quality of HyperArc compared to CyberKnife or Gamma Knife, however there are limited number of studies that include all three modalities. It is the aim of this study to provide an assessment of plan quality between the three SRS platforms across ten patients with multiple brain metastases ranging from three to eight metastases per patient. Strict planning workflows were established to avoid bias towards any particular treatment platform. Plan quality was assessed through dose to organs at risk, Paddick conformity index (PCI), gradient index (GI), global efficiency index (Gη) and dose to normal brain tissue. Results from this study found mean PCI observed across Gamma Knife plans was significantly lower than HyperArc and CyberKnife. HyperArc plans observed significantly shorter beam-on times which were 10 to 20 times faster than CyberKnife and Gamma Knife plans. Gamma Knife and CyberKnife were found to produce plans with significantly superior GI, global efficiency index and the volume of healthy brain receiving greater than 12 Gy (V12Gy) when compared to HyperArc plans. Lesion volume was seen to influence the relative difference in dose metrics between systems. The study revealed that all three treatment modalities produced high quality plans for the SRS treatment of multiple brain metastases, each with respective benefits and limitations.
Collapse
Affiliation(s)
- K Hiscoke
- Bowen Icon Cancer Centre, Wellington, New Zealand
| | - A Leong
- Bowen Icon Cancer Centre, Wellington, New Zealand
- Department of Radiation Therapy, University of Otago, Wellington, New Zealand
| | - A M Hogan
- Department of Medical Physics, The Harley Street Clinic, London, United Kingdom
| | - I Cowley
- Department of Medical Physics, The Harley Street Clinic, London, United Kingdom
| |
Collapse
|
11
|
Hanvey S, Hackett P, Winch L, Lim E, Laney R, Welsh L. A multi-centre stereotactic radiosurgery planning study of multiple brain metastases using isocentric linear accelerators with 5 and 2.5 mm width multi-leaf collimators, CyberKnife and Gamma Knife. BJR Open 2024; 6:tzae003. [PMID: 38371494 PMCID: PMC10873585 DOI: 10.1093/bjro/tzae003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 02/15/2024] [Accepted: 02/15/2024] [Indexed: 02/20/2024] Open
Abstract
Objectives This study compared plans of high definition (HD), 2.5 mm width multi-leaf collimator (MLC), to standard, 5 mm width, isocentric linear accelerator (linacs), CyberKnife (CK), and Gamma Knife (GK) for stereotactic radiosurgery (SRS) techniques on multiple brain metastases. Methods Eleven patients undergoing SRS for multiple brain metastases were chosen. Targets and organs at risk (OARs) were delineated and optimized SRS plans were generated and compared. Results The linacs delivered similar conformity index (CI) values, but the gradient index (GI) for HD MLCs was significantly lower (P-value <.001). Half the OARs received significantly lower dose using HD MLCs. CK delivered a significantly lower CI than HD MLC linac (P-value <.001), but a significantly higher GI (P-value <.001). CI was significantly improved with the HD MLC linac compared to GK (P-value = 4.591 × 10-3), however, GK delivered a significantly lower GI (P-value <.001). OAR dose sparing was similar for the HD MLC TL, CK, and GK. Conclusions Comparing linacs for SRS, the preferred choice is HD MLCs. Similar results were achieved with the HD MLC linac, CK, or GK, with each delivering significant improvements in different aspects of plan quality. Advances in knowledge This article is the first to compare HD and standard width MLC linac plans using a combination of single isocentre volumetric modulated arc therapy and multi-isocentric dynamic conformal arc plans as required, which is a more clinically relevant assessment. Furthermore, it compares these plans with CK and GK, assessing the relative merits of each technique.
Collapse
Affiliation(s)
- Scott Hanvey
- University Hospitals Plymouth NHS Trust, Plymouth, PL6 8DH, United Kingdom
| | | | - Lucy Winch
- University Hospitals Bristol NHS Foundation Trust, Bristol, BS2 8ED, United Kingdom
| | - Elizabeth Lim
- University Hospitals Plymouth NHS Trust, Plymouth, PL6 8DH, United Kingdom
- University of Plymouth, Plymouth, PL4 8AA, United Kingdom
| | - Robin Laney
- University Hospitals Plymouth NHS Trust, Plymouth, PL6 8DH, United Kingdom
| | - Liam Welsh
- The Royal Marsden, London, SW3 6JJ, United Kingdom
| |
Collapse
|
12
|
Brown MH, Marcrom SR, Patel MP, Popple RA, Travis RL, McDonald AM, Riley KO, Markert JM, Willey CD, Bredel M, Fiveash JB, Thomas EM. Understanding the Effect of Prescription Isodose in Single-Fraction Stereotactic Radiosurgery on Plan Quality and Clinical Outcomes for Solid Brain Metastases. Neurosurgery 2023; 93:1313-1318. [PMID: 37449861 PMCID: PMC10627625 DOI: 10.1227/neu.0000000000002585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Accepted: 05/05/2023] [Indexed: 07/18/2023] Open
Abstract
BACKGROUND AND OBJECTIVES There is wide variation in treatment planning strategy for central nervous system (CNS) stereotactic radiosurgery. We sought to understand what relationships exist between intratumor maximum dose and local control (LC) or CNS toxicity, and dosimetric effects of constraining hotspots on plan quality of multiple metastases volumetric modulated arc therapy radiosurgery plans. METHODS We captured brain metastases from 2015 to 2017 treated with single-isocenter volumetric modulated arc therapy radiosurgery. Included tumors received single-fraction stereotactic radiosurgery, had no previous surgery or radiation, and available follow-up imaging. Our criterion for local failure was 25% increase in tumor diameter on follow-up MRI or pathologic confirmation of tumor recurrence. We defined significant CNS toxicity as Radiation Therapy Oncology Group irreversible Grade 3 or higher. We performed univariate and multivariate analyses evaluating factors affecting LC. We examined 10 stereotactic radiosurgery plans with prescriptions of 18 Gy to all targets originally planned without constraints on the maximum dose within the tumor. We replanned each with a constraint of Dmax 120%. We compared V50%, mean brain dose, and Dmax between plans. RESULTS Five hundred and thirty tumors in 116 patients were available for analysis. Median prescription dose was 18 Gy, and median prescription isodose line (IDL) was 73%. Kaplan-Meier estimate of 12-month LC only tumor volume (HR 1.43 [1.22-1.68] P < .001) was predictive of local failure on univariate analysis; prescription IDL and histology were not. In multivariate analysis, tumor volume impacted local failure (HR 1.43 [1.22-1.69] P < .001) but prescription IDL did not (HR 0.95 [0.86-1.05] P = .288). Only a single grade 3 and 2 grade 4 toxicities were observed; tumor volume was predictive of CNS toxicity (HR 1.58 [1.25-2.00]; P < .001), whereas prescription IDL was not (HR 1.01 [0.87-1.17] P = .940). CONCLUSION The prescription isodose line had no impact on local tumor control or CNS toxicity. Penalizing radiosurgery hotspots resulted in worse radiosurgery plans with poorer gradient. Limiting maximum dose in gross tumor causes increased collateral exposure to surrounding tissue and should be avoided.
Collapse
Affiliation(s)
- Matthew H. Brown
- Department of Radiation Oncology, University of Maryland, Baltimore, Maryland, USA
| | - Samuel R. Marcrom
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Mayank P. Patel
- Department of Radiation Oncology, University of Miami, Coral Gables, Florida, USA
| | - Richard A. Popple
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Roman L. Travis
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Andrew M. McDonald
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Kristen O. Riley
- Department of Neurosurgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - James M. Markert
- Department of Neurosurgery, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Christopher D. Willey
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Markus Bredel
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - John B. Fiveash
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Evan M. Thomas
- Department of Radiation Oncology, Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
13
|
Bodensohn R, Maier SH, Belka C, Minniti G, Niyazi M. Stereotactic Radiosurgery of Multiple Brain Metastases: A Review of Treatment Techniques. Cancers (Basel) 2023; 15:5404. [PMID: 38001664 PMCID: PMC10670108 DOI: 10.3390/cancers15225404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/22/2023] [Accepted: 11/11/2023] [Indexed: 11/26/2023] Open
Abstract
The advancement of systemic targeted treatments has led to improvements in the management of metastatic disease, particularly in terms of survival outcomes. However, brain metastases remain less responsive to systemic therapies, underscoring the significance of local interventions for comprehensive disease control. Over the past years, the threshold for treating brain metastases through stereotactic radiosurgery has risen. Yet, as the number of treated metastases increases, treatment complexity and duration also escalate. This trend has made multi-isocenter radiosurgery treatments, such as those with the Gamma Knife, challenging to plan and lengthy for patients. In contrast, single-isocenter approaches employing linear accelerators offer an efficient and expeditious treatment option. This review delves into the literature, comparing different linear-accelerator-based techniques with each other and in relation to dedicated systems, focusing on dosimetric considerations and feasibility.
Collapse
Affiliation(s)
- Raphael Bodensohn
- Department of Radiation Oncology, University Hospital Tübingen, 72076 Tübingen, Germany;
- Center for Neuro-Oncology, Comprehensive Cancer Center Tübingen-Stuttgart, University Hospital Tübingen, 72076 Tübingen, Germany
| | - Sebastian H. Maier
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, 81377 Munich, Germany; (S.H.M.); (C.B.)
| | - Claus Belka
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, 81377 Munich, Germany; (S.H.M.); (C.B.)
- German Cancer Consortium (DKTK), Partner Site Munich, A Partnership between DKFZ and LMU University Hospital, 81377 Munich, Germany
- Bavarian Cancer Research Center (BZKF), Munich, Germany
| | - Giuseppe Minniti
- IRCCS Neuromed, 86077 Pozzilli, Italy;
- Department of Radiological Sciences, Oncology and Anatomical Pathology, Sapienza University of Rome, Policlinico Umberto I, 00161 Rome, Italy
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital Tübingen, 72076 Tübingen, Germany;
- Center for Neuro-Oncology, Comprehensive Cancer Center Tübingen-Stuttgart, University Hospital Tübingen, 72076 Tübingen, Germany
- Department of Radiation Oncology, LMU University Hospital, LMU Munich, 81377 Munich, Germany; (S.H.M.); (C.B.)
- German Cancer Consortium (DKTK), Partner Site Tübingen, A Partnership between DKFZ and University Hospital, 72076 Tübingen, Germany
| |
Collapse
|
14
|
Paddick I, Mott J, Bedford J, Filatov P, Grishchuk D, Orchin G, Houston P, Eaton DJ. Benchmarking Tests of Contemporary SRS Platforms: Have Technological Developments Resulted in Improved Treatment Plan Quality? Pract Radiat Oncol 2023; 13:e451-e459. [PMID: 37290672 DOI: 10.1016/j.prro.2023.05.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 04/28/2023] [Accepted: 05/02/2023] [Indexed: 06/10/2023]
Abstract
PURPOSE Stereotactic radiosurgery treatment delivery can be performed with a range of devices, each of which have evolved over recent years. We sought to evaluate the differences in performance of contemporary stereotactic radiosurgery platforms and also to compare them with earlier platform iterations from a previous benchmarking study. METHODS AND MATERIALS The following platforms were selected as "state of the art" in 2022: Gamma Knife Icon (GK), CyberKnife S7 (CK), Brainlab Elements (Elekta VersaHD and Varian TrueBeam), Varian Edge with HyperArc (HA), and Zap-X. Six benchmarking cases were used from a 2016 study. To reflect the evolution of increasing numbers of metastases treated per patient, a 14-target case was added. The 28 targets among the 7 patients ranged from 0.02 to 7.2 cc in volume. Participating centers were sent images and contours for each patient and asked to plan them to the best of their ability. Although some variation in local practice was allowed (eg, margins), groups were asked to prescribe a specified dose to each target and tolerance doses to organs at risk were agreed upon. Parameters compared included coverage, selectivity, Paddick conformity index, gradient index (GI), R50%, efficiency index, doses to organs at risk, and planning and treatment times. RESULTS Mean coverage for all targets ranged from 98.2% (Brainlab/Elekta) to 99.7% (HA-6X). Paddick conformity index values ranged from 0.722 (Zap-X) to 0.894 (CK). GI ranged from a mean of 3.52 (GK), representing the steepest dose gradient, to 5.08 (HA-10X). The GI appeared to follow a trend with beam energy, with the lowest values from the lower energy platforms (GK, 1.25 MeV; Zap-X, 3 MV) and the highest value from the highest energy (HA-10X). Mean R50% values ranged from 4.48 (GK) to 5.98 (HA-10X). Treatment times were lowest for C-arm linear accelerators. CONCLUSIONS Compared with earlier studies, newer equipment appears to deliver higher quality treatments. CyberKnife and linear accelerator platforms appear to give higher conformity whereas lower energy platforms yield a steeper dose gradient.
Collapse
Affiliation(s)
- Ian Paddick
- Queen Square Radiosurgery Centre, National Hospital for Neurology and Neurosurgery, London, United Kingdom.
| | - Judith Mott
- Northern Centre for Cancer Care, Department of Radiotherapy Physics, Newcastle upon Tyne Hospital NHS Foundation Trust, Newcastle upon Tyne, United Kingdom
| | - James Bedford
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Petr Filatov
- Department of Medical Physics, GenesisCare, Oxford, United Kingdom
| | - Diana Grishchuk
- Queen Square Radiosurgery Centre, National Hospital for Neurology and Neurosurgery, London, United Kingdom
| | - Gavin Orchin
- Beatson West of Scotland Cancer Centre, Department of Radiotherapy Physics, NHS Greater Glasgow & Clyde, Glasgow, United Kingdom
| | - Peter Houston
- Beatson West of Scotland Cancer Centre, Department of Medical Physics, NHS Greater Glasgow & Clyde, Glasgow, United Kingdom
| | - David J Eaton
- Department of Medical Physics, Guy's and St Thomas' NHS Foundation Trust, School of Biomedical Engineering & Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
15
|
Sağlam Y. A novel weight optimized dynamic conformal arcs with TrueBeam™ Linac for very small tumors (≤1 cc) with single isocenter of multiple brain metastases (2≤, ≥4) in stereotactic radiosurgery: A comparison with volumetric modulated arc therapy. J Cancer Res Ther 2023; 19:1297-1304. [PMID: 37787298 DOI: 10.4103/jcrt.jcrt_1829_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Introduction We evaluated whether improved increase delivery efficiency of weight optimized dynamic conformal arc (WO-DCA) therapy in comparison to volumetric modulated arc therapy (VMAT) with single isocenter for SRS treatment of very small volume and multiple brain metastases (BMs). Materials and Methods 20 patients having a less than 1 cc volume and 2≤, ≥4 of multiple BMs, redesigned for 20 Gy in 1 fraction using WO-DCA and VMAT techniques with double full coplanar and three partial noncoplanar arcs. Plan qualities were compared using tumor coverage, conformity index (CI), gradient index (GI), V4Gy, V10Gy, and V12Gy volumes of brain, monitor units (MUs), and percent of quality assurance pass rate (QA%). Results Both techniques satisfied clinical requirements in coverage and CI. VMAT had a significantly higher MU and mean GI than WO-DCA (for MUs; 2330 vs. 1991; P < 0.001, and for GI; 4.72 vs. 3.39; P < 0.001). WO-DCA was found significantly lower V4Gy (171.11 vs. 232.80 cm3, P < 0.001), V10Gy (25.82 vs. 29.71 cm3, P < 0.05), and V12Gy (14.35 vs. 17.28 cm3, P < 0.05) volumes than VMAT. WO-DCA was associated with markedly increase QA pass rates for all plans (97.65% vs. 92.64%, P < 0.001). Conclusions WO-DCA may be the first choice compared to the VMAT in reducing the dose in the brain and minimizing small-field dosimetric errors for very small SRS treatment of brain metastases in the range of ≤ 1 cc and 2≤, ≥4.
Collapse
Affiliation(s)
- Yücel Sağlam
- Department of Radiation Oncology, School of Medicine, Koc University, Topkapi, Istanbul, Turkey
| |
Collapse
|
16
|
Huang YY, Yang J, Liu YB. Planning issues on linac-based stereotactic radiotherapy. World J Clin Cases 2022; 10:12822-12836. [PMID: 36568990 PMCID: PMC9782937 DOI: 10.12998/wjcc.v10.i35.12822] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/20/2022] [Accepted: 11/14/2022] [Indexed: 12/14/2022] Open
Abstract
This work aims to summarize and evaluate the current planning progress based on the linear accelerator in stereotactic radiotherapy (SRT). The specific techniques include 3-dimensional conformal radiotherapy, dynamic conformal arc therapy, intensity-modulated radiotherapy, and volumetric-modulated arc therapy (VMAT). They are all designed to deliver higher doses to the target volume while reducing damage to normal tissues; among them, VMAT shows better prospects for application. This paper reviews and summarizes several issues on the planning of SRT to provide a reference for clinical application.
Collapse
Affiliation(s)
- Yang-Yang Huang
- School of Nuclear Science and Engineering, East China University of Technology, Nanchang 330013, Jiangxi Province, China
- Department of Radiotherapy, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou 450014, Henan Province, China
| | - Jun Yang
- Department of Radiotherapy, The Third Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Yi-Bao Liu
- School of Nuclear Science and Engineering, East China University of Technology, Nanchang 330013, Jiangxi Province, China
| |
Collapse
|
17
|
V HP, R M, N ANR, S S. A Comprehensive Evaluation of Single Isocenter Multiple Target SRS Plans and the Analytical Relationship between Plan Quality Indices with the Number and Volume of Targets. Asian Pac J Cancer Prev 2022; 23:3103-3112. [PMID: 36172673 PMCID: PMC9810297 DOI: 10.31557/apjcp.2022.23.9.3103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Indexed: 01/09/2023] Open
Abstract
OBJECTIVE To study the relationship of plan quality indices with the number and volume of target for 5 to 10 brain metastases treated with LINAC-based Single Isocenter Multiple Target (SIMT) Stereotactic radiosurgery (SRS) planning and to determine the maximum volume of spherical targets treated without exceeding the normal tissue tolerances. METHODS Spherical targets of 5 to 10 numbers per plan, with individual target volumes ranging from 0.025 cc to 11.5 cc, were simulated with randomly drawn planning target volumes (PTVs) within the brain. SIMT SRS plans were generated for the 21 Gy prescription dose with a 6 MV Flattening Filter Free photon beam. Target coverage, organ at risk sparing, plan quality indices, R50%, and gradient measure were studied. Mean brain dose, V12 for Brain minus PTV (BmP), V10, V12, V15, V18, V20, and V24 for brain volume were evaluated. Equations relating the gradient index, mean brain dose, and V12 (BmP) to the given number and volume of the targets were constructed. RESULTS PTV coverage D98 was 98.77 ± 1.37 %. The mean CIRTOG, QRTOG, HIRTOG, CIP, GI, and R50% of the individual targets were 1.02 ± 0.08, 0.94 ± 0.02, 1.49 ± 0.11, 0.91 ± 0.06, 4.74 ± 2.3, and 4.95 ± 2.67, respectively. The gradient measure achieved was in the range of 0.49 to 1.35 cm. The mean brain dose was in the range of 1.62 to 6.69 Gy. The mean V12 (BmP) per target obtained was 3.85 ± 2.83 cc. CONCLUSION Equations relating the number and volume of targets to the gradient measure, mean brain dose, V12 (BmP), and V10-24 can serve as a baseline for multiple brain metastases SIMT planning. The target volume for 5, 6, 7, 8, 9, and 10 targets that can be treated without exceeding V12 (BmP) is 6, 5, 4.7, 4, 3.7, and 3.4 cc, respectively, for the 21 Gy prescription dose.
Collapse
Affiliation(s)
- Hemalatha Priyadarsini V
- Tamil Nadu Medical Services Corporation Ltd, 417, Pantheon road, Egmore, Chennai, Tamil Nadu, India. ,Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, Tamil Nadu, India. ,Department of Radiation Oncology, Government Royapettah Hospital, 1, West Cott road, Royapettah, Chennai, Tamil Nadu, India.
| | - Murali R
- Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, Tamil Nadu, India. ,For Correspondence:
| | - Arunai Nambi Raj N
- Department of Physics, School of Advanced Sciences, Vellore Institute of Technology, Vellore, Tamil Nadu, India.
| | - Saravanan S
- Department of Radiation Oncology, Government Royapettah Hospital, 1, West Cott road, Royapettah, Chennai, Tamil Nadu, India.
| |
Collapse
|
18
|
Chan M, Gevaert T, Kadoya N, Dorr J, Leung R, Alheet S, Toutaoui A, Farias R, Wong M, Skourou C, Valenti M, Farré I, Otero-Martínez C, O'Doherty D, Waldron J, Hanvey S, Grohmann M, Liu H. Multi-center planning study of radiosurgery for intracranial metastases through Automation (MC-PRIMA) by crowdsourcing prior web-based plan challenge study. Phys Med 2022; 95:73-82. [DOI: 10.1016/j.ejmp.2022.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 01/10/2022] [Accepted: 01/28/2022] [Indexed: 10/19/2022] Open
|
19
|
Baba MH, Singh BK. In vitro quality assurance of three-dimensional conformal radiotherapy mono-isocentric plan for simultaneous treatment of two targets. Int J Health Sci (Qassim) 2022; 16:17-21. [PMID: 35024030 PMCID: PMC8721211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
OBJECTIVE The purpose of this study was to check the in vitro efficacy of a radiotherapy plan generated for the treatment of two femoral targets simultaneously in the pelvis. METHODS The target positions for conformal radiotherapy were simulated by joining two identical water phantoms (approximating the patient dimensions), and a treatment plan to treat the two targets simultaneously with a common isocenter was planned. Calculations were made with a dose prescription of 300cGy to each lesion. The plan was executed on a medical linear accelerator and verified for point doses for individual targets with two ion chambers. Two-dimensional dose verification for fluence was also performed using an array detector of ion chambers (I'mRTMatriXX) to further validate the technique. RESULTS The minimum, mean and maximum dose in centiGray(cGy) covered by both Ionization Chamber-1 (IC-1) and Ionization Chamber-2 (IC-2) was 295, 303 and 307 as per dose statistics from the treatment plan. The global dose max obtained from the plan was 307 cGy. Measured point doses to both the targets were within ±2%. Dose Difference and Distance to agreement (3%, 3 mm criteria) criteria also passed for 2Dfluence verification. CONCLUSIONS Radiotherapy of two or multiple targets using monoisocentric technique can appreciably reduce the scatter dose to the normal surrounding tissue around the target/s and also the required setup and treatment time is reduced significantly. Therefore, the technique can be efficiently used to save time without compromising the radio therapeutic ratio and quality treatment, for both palliative and curative intent.
Collapse
Affiliation(s)
- Misba Hamid Baba
- Department of Physics, Institute of Applied Sciences and Humanities, GLA University, Mathura, Uttar Pradesh, India
- Department of Radiological Physics, Sher I Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India
| | - Benoy Kumar Singh
- Department of Physics, Institute of Applied Sciences and Humanities, GLA University, Mathura, Uttar Pradesh, India
| |
Collapse
|
20
|
Ferini G, Viola A, Valenti V, Tripoli A, Molino L, Marchese VA, Illari SI, Rita Borzì G, Prestifilippo A, Umana GE, Martorana E, Mortellaro G, Ferrera G, Cacciola A, Lillo S, Pontoriero A, Pergolizzi S, Parisi S. Whole Brain Irradiation or Stereotactic RadioSurgery for five or more brain metastases (WHOBI-STER): A prospective comparative study of neurocognitive outcomes, level of autonomy in daily activities and quality of life. Clin Transl Radiat Oncol 2021; 32:52-58. [PMID: 34926839 PMCID: PMC8649107 DOI: 10.1016/j.ctro.2021.11.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Revised: 11/18/2021] [Accepted: 11/21/2021] [Indexed: 02/07/2023] Open
Abstract
The main aim of MBM treatment is to palliate neurological symptoms and to maintain an adequate QoL. SRT could be the “new standard” over WBI in the management of MBM patients. Neurocognitive functions could deteriorate more after WBI than after SRT.
Aims To evaluate neurocognitive performance, daily activity and quality of life (QoL), other than usual oncologic outcomes, among patients with brain metastasis ≥5 (MBM) from solid tumors treated with Stereotactic Brain Irradiation (SBI) or Whole Brain Irradiation (WBI). Methods This multicentric randomized controlled trial will involve the enrollment of 100 patients (50 for each arm) with MBM ≥ 5, age ≥ 18 years, Karnofsky Performance Status (KPS) ≥ 70, life expectancy > 3 months, known primary tumor, with controlled or controllable extracranial disease, baseline Montreal Cognitive Assessment (MoCA) score ≥ 20/30, Barthel Activities of Daily Living score ≥ 90/100, to be submitted to SBI by LINAC with monoisocentric technique and non-coplanar arcs (experimental arm) or to WBI (control arm). The primary endpoints are neurocognitive performance, QoL and autonomy in daily-life activities variations, the first one assessed by MoCa Score and Hopkins Verbal Learning Test-Revised, the second one through the EORTC QLQ-C15-PAL and QLQ-BN-20 questionnaires, the third one through the Barthel Index, respectively. The secondary endpoints are time to intracranial failure, overall survival, retreatment rate, acute and late toxicities, changing of KPS. It will be considered significant a statistical difference of at least 30% between the two arms (statistical power of 80% with a significance level of 95%). Discussion Several studies debate what is the decisive factor accountable for the development of neurocognitive decay among patients undergoing brain irradiation for MBM: radiation effect on clinically healthy brain tissue or intracranial tumor burden? The answer to this question may come from the recent technological advancement that allows, in a context of a significant time saving, improved patient comfort and minimizing radiation dose to off-target brain, a selective treatment of MBM simultaneously, otherwise attackable only by WBI. The achievement of a local control rate comparable to that obtained with WBI remains the fundamental prerequisite. Trial registration NCT number: NCT04891471.
Collapse
Key Words
- 3D-CRT, 3Dimensional-ConformalRadioTherapy
- Autonomy in daily activities
- BSC, Best Supportive Care
- Brain metastases
- CRF, Case Report Form
- CT, Computerized Tomography
- CTV, Clinical Target Volume
- EORTC QLQ-C15-PAL, European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 15 for Palliative Care
- FSRT, Fractionated Stereotactic Radiation Therapy
- GTV, Gross Tumor Volume
- KPS, Karnofsky Performance Status
- LINAC, Linear Accelerator
- MBM, Multiple Brain Metastastes
- MRI, Magnetic Resonance Imaging
- MoCA, Montreal Cognitive Assessment
- NCCN, National Comprehensive Cancer Network
- Neurocognitive decay
- Neurocognitive performance
- Neurocognitive tests
- OAR, Organ At Risk
- OS, Overall Survival
- PTV, Planning Target Volume
- Palliative care
- QLQ-BN20, Quality of Life Questionnaire - Brain Neoplasm 20
- QoL, Quality of Life
- Quality of life
- RT, Radiation Therapy
- RTOG, Radiation Therapy Oncology Group
- Radiotherapy for multiple brain metastases
- SBI, Stereotactic Brain Irradiation
- SRS, Stereotactic RadioSurgery
- SRT, Stereotactic Radiation Therapy
- Stereotactic Brain RadioSurgery
- Stereotactic Brain Radiotherapy
- Supportive care in cancer patients
- VEGF, Vascular Endothelial Growth Factor
- Whole Brain Radiotherapy
Collapse
Affiliation(s)
| | - Anna Viola
- Fondazione IOM, Viagrande, I-95029 Catania, Italy
| | - Vito Valenti
- REM Radioterapia srl, Viagrande, I-95029 Catania, Italy
| | | | - Laura Molino
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali Università di Messina, I-98100 Messina, Italy
| | | | | | | | - Angela Prestifilippo
- Medical Oncology Unit, Mediterranean Institute of Oncology, Viagrande, I-95029 Catania, Italy
| | - Giuseppe Emmanuele Umana
- Trauma Center, Gamma Knife Center, Department of Neurosurgery, Cannizzaro Hospital, I-95125 Catania, Italy
| | | | - Gianluca Mortellaro
- Department of Radiation Oncology, ARNAS Ospedale Civico, I-90127 Palermo, Italy
| | - Giuseppe Ferrera
- Department of Radiation Oncology, ARNAS Ospedale Civico, I-90127 Palermo, Italy
| | - Alberto Cacciola
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali Università di Messina, I-98100 Messina, Italy
| | - Sara Lillo
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali Università di Messina, I-98100 Messina, Italy
| | - Antonio Pontoriero
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali Università di Messina, I-98100 Messina, Italy
| | - Stefano Pergolizzi
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali Università di Messina, I-98100 Messina, Italy
| | - Silvana Parisi
- Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali Università di Messina, I-98100 Messina, Italy
| |
Collapse
|
21
|
Radiotherapy in Current Neuro-Oncology: There Is Still Much to Reveal. Life (Basel) 2021; 11:life11121412. [PMID: 34947942 PMCID: PMC8706956 DOI: 10.3390/life11121412] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 12/11/2021] [Accepted: 12/16/2021] [Indexed: 01/07/2023] Open
|
22
|
Skourou C, Hickey D, Rock L, Houston P, Sturt P, O' Sullivan S, Faul C, Paddick I. Treatment of multiple intracranial metastases in radiation oncology: a contemporary review of available technologies. BJR Open 2021; 3:20210035. [PMID: 34877458 PMCID: PMC8611687 DOI: 10.1259/bjro.20210035] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 08/06/2021] [Indexed: 12/31/2022] Open
Abstract
The use of stereotactic radiosurgery to treat multiple intracranial metastases, frequently concurrently, has become increasingly common. The ability to accurately and safely deliver stereotactic radiosurgery treatment to multiple intracranial metastases (MIM) relies heavily on the technology available for targeting, planning, and delivering the dose. A number of platforms are currently marketed for such applications, each with intrinsic capabilities and limitations. These can be broadly categorised as cobalt-based, linac-based, and robotic. This review describes the most common representative technologies for each type along with their advantages and current limitations as they pertain to the treatment of multiple intracranial metastases. Each technology was used to plan five clinical cases selected to represent the clinical breadth of multiple metastases cases. The reviewers discuss the different strengths and limitations attributed to each technology in the case of MIM as well as the impact of disease-specific characteristics (such as total number of intracranial metastases, their size and relative proximity) on plan and treatment quality.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Clare Faul
- St. Luke’s Radiation Oncology Network, Dublin, Ireland
| | - Ian Paddick
- Queen Square Radiosurgery Centre, National Hospital for Neurology and Neurosurgery, London, UK
| |
Collapse
|