1
|
Cogan CJ, Patel M, Guevara J, Sahoo S, Jun BJ, Zhang C, Shemo C, Baker A, Qi A, Entezari V, Iannotti JP, Ho JC, Ricchetti ET. Short-term outcomes of anatomic total shoulder arthroplasty with nonaugmented glenoid component for Walch B2 and B3 glenoid morphology. J Shoulder Elbow Surg 2025; 34:S10-S21. [PMID: 39961471 DOI: 10.1016/j.jse.2025.01.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2024] [Revised: 01/12/2025] [Accepted: 01/18/2025] [Indexed: 05/13/2025]
Abstract
BACKGROUND The optimal management of posterior glenoid bone loss in glenohumeral osteoarthritis with anatomic total shoulder arthroplasty (aTSA) remains unknown, as the degree of bone loss and retroversion can vary across a wide spectrum in glenoids with Walch B2 and B3 morphology. The objectives of the current study were to evaluate the clinical and radiographic outcomes of utilizing standard, all-polyethylene, nonaugmented anchor-peg glenoid (APG) components in aTSA for patients with mild to moderate B2 or B3 morphology. METHODS Between January 2010 and September 2019, we identified 79 shoulders with mild to moderate B2 or B3 glenoid morphology that underwent aTSA with use of a nonaugmented APG glenoid component and minimum 2 years clinical and radiographic follow-up. In each case, the surgeon had access to an augmented glenoid component but chose to use a standard component based upon the presence of mild to moderate deformity, defined as the ability to template components within 10° of premorbid glenoid vault retroversion and within 3 mm of premorbid glenoid vault joint line based on preoperative 3-dimensional computed tomography planning. The Penn Shoulder Score (PSS), glenoid anchor-peg osteolysis (APO) (grade 1 vs. 2 and 3), and humeral head subluxation (HHS) were the main outcomes of interest. RESULTS The cohort included 63/79 (80%) B2 glenoids and 17/79 (21%) B3 glenoids. Median patient age at surgery was 64.2 years [interquartile range {IQR} 59.6; 68.5]; median preoperative retroversion was 13.0° [IQR 9.8; 15.4]; and median preoperative joint line medialization was 1.4 mm [IQR 0.4; 2.4]. Median follow-up duration was 4.3 years [IQR 2.5; 6.8]; The PSS and HHS were improved amongst all patients postoperatively (P < .0001), with a median PSS at latest follow-up of 96.0 [IQR 88.5; 99.0] and posterior HHS present in 11.8% at final follow-up. There were 4 complications in the cohort (5.0%), one of which required reoperation due to persistent posterior HHS. Postoperative grade 1 APO was present on latest radiographs in 8/79 (10.1%) cases. Walch classification, preoperative glenoid version, inclination, and joint line medialization as measured on 3-dimensional computed tomography were not significantly associated with PSS or APO at final follow-up. Higher PSS at final follow-up was associated with better shoulder range of motion. APO at final follow-up was not associated with lower PSS. DISCUSSION The use of nonaugmented polyethylene APG components in patients undergoing aTSA with mild to moderate B2 and B3 glenoids results in significant improvements in clinical and radiographic outcomes with low complication and reoperation rates at short-term follow-up. Further follow-up of this cohort is needed to better understand the implications of glenoid component APO on loosening patterns and failure rates in the long-term.
Collapse
Affiliation(s)
- Charles J Cogan
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA.
| | - Midhat Patel
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Jonathan Guevara
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Sambit Sahoo
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Bong Jae Jun
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Chao Zhang
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Cathy Shemo
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Andrew Baker
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Andrew Qi
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Vahid Entezari
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Joseph P Iannotti
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Jason C Ho
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| | - Eric T Ricchetti
- Cleveland Clinic Foundation, Department of Orthopaedic Surgery, Cleveland, OH, USA
| |
Collapse
|
2
|
Miettinen SSA, Liu Y, Kröger H. Long-term survival of resurfacing humeral hemiarthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:2925-2932. [PMID: 38809422 PMCID: PMC11377525 DOI: 10.1007/s00590-024-04010-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Accepted: 05/22/2024] [Indexed: 05/30/2024]
Abstract
INTRODUCTION The indication for shoulder resurfacing arthroplasty is controversial, and survival of these implants is somewhat inconsistent. This study aimed to evaluate the long-term survivorship of resurfacing humeral head implants (RHHIs) and determine risk factors for complications and revisions. MATERIALS AND METHODS This retrospective cohort study consisted of 275 cases and two types of RHHIs. The survival rate was evaluated using the Kaplan-Meier method and Cox regression for risk factor analysis. Demographic factors were studied, and the change in the humerus centre of rotation (COR) was measured. RESULTS The mean follow-up time was 8.7 years (SD 2.7 months, range 2.8-15.9 years). The mean age of the patients was 67.6 years (SD 9.6, range 33.5-84.9). Ten-year cumulative RHHI survival was 94.1%. The cumulative estimate without any complication was 98.9% at 5 years, 80.0% at 10 years and at 15 years it was 61.5%. The most common complication was persistent pain in 13.8% of the RHHIs. The risk factors for complications and revisions were implant type, preoperative conditions and change of COR > 5 mm. CONCLUSIONS RRHIs showed excellent long-term survival, but many complications were found. The most common complication was persistent pain, which seemed to be caused by a change of COR and was more related to one type of implant.
Collapse
Affiliation(s)
- Simo S A Miettinen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211, Kuopio, Finland.
- Kuopio Musculoskeletal Research Unit (KMRU), Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland.
| | - Yang Liu
- Kuopio Musculoskeletal Research Unit (KMRU), Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| | - Heikki Kröger
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211, Kuopio, Finland
- Kuopio Musculoskeletal Research Unit (KMRU), Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland
| |
Collapse
|
3
|
Fares MY, Singh J, Boufadel P, Cohn MR, Abboud JA. Pyrocarbon hemiarthroplasty and the shoulder: biomechanical and clinical results of an emerging treatment option. Clin Shoulder Elb 2024; 27:117-125. [PMID: 37442777 PMCID: PMC10938019 DOI: 10.5397/cise.2023.00024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 01/31/2023] [Accepted: 02/04/2023] [Indexed: 07/15/2023] Open
Abstract
While shoulder hemiarthroplasty is still used to treat young patients with shoulder pathology, the use of this procedure has substantially declined in recent years due to its significant complication profile. Glenoid wear with arthrosis is one of the major postoperative complications following shoulder hemiarthroplasty, and efforts to prevent this complication led many scientists to explore alternative weight-bearing surfaces on arthroplasty implants to decrease joint wear and improve patient outcomes. Pyrolytic carbon, or pyrocarbon, is a material that has better biocompatibility, survivorship, strength, and wear resistance compared to the materials used in traditional shoulder hemiarthroplasty. Pyrocarbon implants have been used in orthopedics for over 50 years; recently, their utility in shoulder hemiarthroplasty has garnered much interest. The purpose behind the use of pyrocarbon in shoulder hemiarthroplasty is to decrease the risk of progressive glenoid wear, especially in young active patients in whom joint preservation is important. Promising survivorship and outcomes have been demonstrated by recent studies, including limited glenoid wear following pyrocarbon hemiarthroplasty. Nevertheless, these clinical studies have been limited to relatively small case series with limited long-term follow-up. Accordingly, additional research and comparative studies need to be conducted in order to properly assess the therapeutic efficacy and value of pyrocarbon hemiarthroplasty.
Collapse
Affiliation(s)
- Mohamad Y. Fares
- Division of Shoulder and Elbow Surgery, Rothman Orthopedic Institute, Philadelphia, PA, USA
| | - Jaspal Singh
- Division of Shoulder and Elbow Surgery, Rothman Orthopedic Institute, Philadelphia, PA, USA
| | - Peter Boufadel
- Division of Shoulder and Elbow Surgery, Rothman Orthopedic Institute, Philadelphia, PA, USA
| | - Matthew R. Cohn
- Division of Shoulder and Elbow Surgery, Rothman Orthopedic Institute, Philadelphia, PA, USA
| | - Joseph A. Abboud
- Division of Shoulder and Elbow Surgery, Rothman Orthopedic Institute, Philadelphia, PA, USA
| |
Collapse
|
4
|
Redfern JAI, Mehta N, Farnebo S, McGuire D, Solomons M, Thomas Thorvaldson K, Estfan R, Brown DJ. Complication rates and modes of short and medium-term failure in Motec total wrist arthroplasty: an international cohort study. J Hand Surg Eur Vol 2024; 49:27-33. [PMID: 37684024 DOI: 10.1177/17531934231195689] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/10/2023]
Abstract
The aim of this study was to analyse the short- and medium-term complications of the Motec total wrist arthroplasty (TWA). Identifying exact modes of failure and their causes should allow surgeons to avoid or mitigate these risks in the future. Retrospective analysis of prospectively collected data from six hand surgeons at five international centres provided details of 171 Motec TWAs. The mean follow-up was 5.8 years (range 18 months to 12 years). There were 33 (19%) complications within our cohort, with a revision rate of 8.2% (14 revisions). There was no difference in complication rates between metal-on-metal and metal-on-polymer articulations. Failure of osseointegration was the most common complication. Problems with soft tissue balancing, implant impingement related osteolysis, bony impingement and metacarpal fracture were found to be other preventable causes of failure in this series. Elimination of these preventable complications will improve survival rates for this implant.Level of evidence: IV.
Collapse
Affiliation(s)
- James A I Redfern
- Liverpool University Hospitals NHS Foundation Trust, Liverpool, UK
- Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK
| | - Nisarg Mehta
- Liverpool University Hospitals NHS Foundation Trust, Liverpool, UK
| | - Simon Farnebo
- Department of Plastic Surgery, Hand Surgery, and Burns, Faculty of Medicine and Health Sciences, Linköping University, Linköping, Sweden
| | - Duncan McGuire
- Martin Singer Hand Unit, Groote Schuur Hospital, Cape Town, South Africa
| | - Michael Solomons
- Martin Singer Hand Unit, Groote Schuur Hospital, Cape Town, South Africa
| | - K Thomas Thorvaldson
- Maitland Hospital, University of Newcastle clinical school, Maitland, NSW, Australia
| | - Rami Estfan
- Southend University Hospital, Mid and South Essex NHS Trust, Southend On Sea, UK
| | - Daniel J Brown
- Liverpool University Hospitals NHS Foundation Trust, Liverpool, UK
- Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK
| |
Collapse
|
5
|
Giannotti S, Troiano E, Saviori M, Crippa Orlandi N, Greco T, Perisano C, Colasanti GB, Mondanelli N. Humeral Resurfacing Arthroplasty: Clinical, Functional and Radiological Assessment at a Mean Follow-Up of 11 Years. PROSTHESIS 2023; 5:1312-1321. [DOI: 10.3390/prosthesis5040090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/27/2024]
Abstract
Humeral resurfacing arthroplasty (HRA) entails the substitution of the articular surface alone with a prosthetic cap without a humeral stem. It is a more conservative procedure which can be easily converted in a total (anatomical or reverse) arthroplasty, if necessary. The present study aimed to evaluate the clinical and radiographical outcomes in a series of patients treated with HRA by a single surgeon. Thirty-three patients with a mean follow-up of 11 years were clinically (Constant score; disability of the arm, shoulder and hand score, DASH) and radiographically assessed before and after surgery. The Constant and DASH scores improved significantly after surgery, and only two cases needed revision surgery. HRA represents a valid therapeutic option in selected cases to improve the quality of life and prevents the need for more invasive procedures.
Collapse
Affiliation(s)
- Stefano Giannotti
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero Universitaria Senese, 53100 Siena, Italy
| | - Elisa Troiano
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero Universitaria Senese, 53100 Siena, Italy
| | - Marco Saviori
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
| | - Nicholas Crippa Orlandi
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero Universitaria Senese, 53100 Siena, Italy
| | - Tommaso Greco
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Carlo Perisano
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Giovanni Battista Colasanti
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero Universitaria Senese, 53100 Siena, Italy
| | - Nicola Mondanelli
- Department of Medicine, Surgery and Neurosciences, University of Siena, 53100 Siena, Italy
- Section of Orthopedics, Azienda Ospedaliero Universitaria Senese, 53100 Siena, Italy
| |
Collapse
|
6
|
Papadopoulos DV, Nikolaou VS, Masouros P, Babis GC, Imbriglia JE. The impact of glenoid parameters and implant overstuffing on functional outcomes of shoulder hemiarthroplasty in patients with glenohumeral joint arthritis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023; 33:3531-3538. [PMID: 37212913 DOI: 10.1007/s00590-023-03584-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 05/10/2023] [Indexed: 05/23/2023]
Abstract
PURPOSE The outcomes of shoulder hemiarthroplasty are highly dependent on the baseline glenoid morphology and the rotator cuff integrity. The objective of this study was to assess whether certain glenoid parameters and implant overstuffing are associated with worse clinical outcomes following shoulder hemiarthroplasty. METHODS We retrospectively reviewed 25 patients who underwent shoulder hemiarthroplasty for shoulder arthritis, with a mean follow-up of 5.3 years. The baseline glenoid morphology, the glenoid wear rate, the proximal humeral head migration and implant overstuffing were evaluated radiologically in all patients. The radiological parameters were correlated with the functional outcomes. RESULTS The Constant-Murley score, the ASES score, and the OSS score were significantly better for patients with a concentric baseline glenoid compared to those with an eccentric glenoid. The Constant-Murley score and the ASES score were also improved in patients without implant overstuffing compared to patients with implant overstuffing (p < 0.05). However, glenoid wear was not associated with worse functional outcomes (p = 0.23 for Constant-Murley score, p = 0.15 for ASES score and p = 0.27 for OSS score). Last, a worse Constant-Murley score was strongly correlated with proximal humeral head migration (p < 0.001), while worse ASES and OSS scores were moderately correlated with proximal humeral head migration (p < 0.001). CONCLUSION Our findings indicate that the results of hemiarthroplasty can be improved through careful selection of patients upon the baseline glenoid type morphology and proper implant sizing to avoid implant overstuffing. Moreover, glenoid wear is not associated with worse clinical outcomes, therefore shoulder hemiarthroplasty should be reconsidered as an alternative in younger patients with shoulder arthritis.
Collapse
Affiliation(s)
| | - Vasileios S Nikolaou
- 2nd Academic Department of Orthopaedics, School of Medicine, Konstandopoulio General Hospital, National & Kapodistrian University of Athens, 3-5 Konstantopoulou Str, 14233, Athens, Greece
| | | | - George C Babis
- 2nd Academic Department of Orthopaedics, School of Medicine, Konstandopoulio General Hospital, National & Kapodistrian University of Athens, 3-5 Konstantopoulou Str, 14233, Athens, Greece
| | - Joseph E Imbriglia
- Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA, USA
| |
Collapse
|
7
|
Jennewine BR, Brolin TJ. Emerging Technologies in Shoulder Arthroplasty: Navigation, Mixed Reality, and Preoperative Planning. Orthop Clin North Am 2023; 54:209-225. [PMID: 36894293 DOI: 10.1016/j.ocl.2022.11.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
Shoulder arthroplasty is a rapidly improving and utilized management for end-stage arthritis that is associated with improved functional outcomes, pain relief, and long-term implant survival. Accurate placement of the glenoid and humeral components is critical for improved outcomes. Traditionally, preoperative planning was limited to radiographs and 2-dimensional computed tomography (CT); however, 3-dimensional CT is becoming more commonly utilized and necessary to understand complex glenoid and humeral deformities. To further increase accurate component placement, intraoperative assistive devices-patient-specific instrumentation, navigation, and mixed reality-minimize malpositioning, increase surgeon accuracy, and maximize fixation. These intraoperative technologies likely represent the future of shoulder arthroplasty.
Collapse
Affiliation(s)
- Brenton R Jennewine
- Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center-Campbell Clinic, 920 Madison Avenue, Memphis, TN 38163, USA; Campbell Clinic Orthopaedics, 1211 Union Avenue #500, Memphis, TN 38104, USA
| | - Tyler J Brolin
- Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center-Campbell Clinic, 920 Madison Avenue, Memphis, TN 38163, USA; Campbell Clinic Orthopaedics, 1400 South Germantown Road, Germantown, TN 38138, USA.
| |
Collapse
|
8
|
Spangenberg GW, Faber KJ, Langohr GDG, Reeves JM. The sizing and suitability of nonspherical ellipsoid humeral heads for total shoulder arthroplasty. J Shoulder Elbow Surg 2023; 32:232-239. [PMID: 36007865 DOI: 10.1016/j.jse.2022.07.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/28/2022] [Accepted: 07/07/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total shoulder arthroplasty (TSA) implants have evolved to include more anatomically shaped components that better replicate the native state. The geometry of the humeral head is nonspherical, with the frontal diameter of the base of the head being up to 6% larger than the sagittal diameter. Despite this, most TSA humeral head implants are spherical, meaning that the diameter must be oversized to achieve complete coverage, resulting in articular overhang, or portions of the resection plane will remain uncovered. It is suggested that implant-bone load transfer between the backside of the humeral head and the cortex on the resection plane may yield better load-transfer characteristics if resection coverage were properly matched without overhang, thereby mitigating proximal stress shielding. METHODS Eight paired cadaveric humeri were prepared for TSA by an orthopedic surgeon who selected and prepared the anatomic humeral resection plane using a cutting guide and a reciprocating sagittal saw. The humeral head was resected, and the resulting cortical boundary of the resection plane was digitized using a stylus and an optical tracking system. To simulate optimal sizing of both circular and elliptical humeral heads, both circles and ellipses were fit to the traces. Two extreme scenarios were also investigated: upsizing until 100% total coverage and downsizing until 0% overhang. RESULTS By switching from a spherical (circular) to an ellipsoid (elliptical) humeral head, a small, 2.3% ± 0.3% increase in total coverage occurred (P < .001), which led to a large, 19.5% ± 1.3% increase in cortical coverage (P < .001). Using a circular head resulted in 2.0% ± 0.1% greater overhang (P < .001), defined as a percentage of the total enclosed area that exceeded the bounds of the humeral resection. As a result of increasing the head size until 100% resection coverage occurred, the ellipse produced 5.4% ± 3.5% less overhang than the circle (P < .001). When the head size was decreased until 0% overhang occurred, total coverage was 7.5% ± 2.8% greater for the ellipse (P < .001) and cortical coverage was 7.9% ± 8.2% greater for the ellipse (P = .01). Cortical coverage was greater for circular heads when the head size was shrunk below -2.25% of the optimal fitted size. DISCUSSION Reconstruction with ellipsoid humeral heads can provide greater total resection and cortical coverage than spherical humeral heads while avoiding excessive overhang; however, cortical coverage can be inferior when undersized. These initial findings suggest that resection-matched humeral heads may yield benefits worth pursuing in the next generation of TSA implant design.
Collapse
Affiliation(s)
- Gregory W Spangenberg
- Department of Mechanical Engineering, Western University, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
| | - Kenneth J Faber
- Roth
- McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada
| | - G Daniel G Langohr
- Department of Mechanical Engineering, Western University, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada.
| | - Jacob M Reeves
- Department of Mechanical Engineering, Western University, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
| |
Collapse
|
9
|
Tøttrup M, Thillemann JK, Thillemann TM, Mechlenburg I, Klebe T, Søballe K, Stilling M. Early offset-increasing migration predicts later revision for humeral head resurfacing implants. A randomized controlled radiostereometry trial with 10-year clinical follow-up. J Orthop Res 2022; 40:2688-2697. [PMID: 35220595 DOI: 10.1002/jor.25298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 02/04/2022] [Accepted: 02/09/2022] [Indexed: 02/04/2023]
Abstract
In a randomized controlled setting, medium-term implant migration and long-term clinical outcomes were compared for the Copeland and the Global C.A.P. humeral head resurfacing implants (HHRI). Thirty-two patients (mean age 63 years) were randomly allocated to a Copeland (n = 14) or Global C.A.P. (n = 18) HHRI. Patients were followed for 5 years with radiostereometry, Constant Shoulder Score, and the Western Ontario Osteoarthritis of the Shoulder Index (WOOS). WOOS and revision status were also obtained cross-sectionally at a mean 10-year follow-up. At the 5-year follow-up, total translation (TT) was 0.75 mm (95% confidence interval [CI]: 0.53-0.97) for the Copeland HHRIs and 1.15 mm (95% CI: 0.85-1.46) for the Global C.A.P. HHRIs (p = 0.04), but the clinical scores were similar at all follow-ups. The cumulative risks of revision at 5 and 10 years were 29% and 43% for Copeland and 35% and 41% for Global C.A.P HHRIs (p > 0.7). No implants were loose at revision, but HHRIs that were later revised followed an early offset-increasing migration pattern with medial translation and lift-off resulting in a mean 0.53 mm (95% CI: 0.18-0.88) higher TT at the 1-year follow-up compared to non-revised HHRIs. In conclusion, the Global C.A.P. HHRI had higher TT compared with the Copeland HHRI, but clinical scores and revision rates were similar. Nonetheless, revision rates were high and challenge the use of HHRIs. Interestingly, an early radiostereometry evaluated HHRI migration pattern with increased off-set predicted later implant revision.
Collapse
Affiliation(s)
- Mikkel Tøttrup
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedics, Aalborg University Hospital, Farsø, Denmark
| | - Janni Kjaergaard Thillemann
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Hospital Unit West, University Clinic of Hand, Hip and Knee Surgery, Holstebro, Denmark
| | - Theis Muncholm Thillemann
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| | - Inger Mechlenburg
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Public Health, Aarhus University, Aarhus, Denmark
| | - Thomas Klebe
- Department of Orthopaedics, Silkeborg Regional Hospital, Silkeborg, Denmark
| | - Kjeld Søballe
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.,Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
10
|
Joyce CD, Patel MS, Stoll K, Singh AM, Stone MA, Horneff JG, Austin L, Lazarus MD. Fixed- vs. variable-angle humeral neck cut in anatomic total shoulder arthroplasty: a randomized controlled trial. J Shoulder Elbow Surg 2022; 31:1674-1681. [PMID: 35537570 DOI: 10.1016/j.jse.2022.03.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 03/21/2022] [Accepted: 03/27/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Variable neck-shaft angle (NSA) stemmed humeral components have been incorporated into certain implant designs to better re-create normal anatomy in total shoulder arthroplasty (TSA). The purpose of this study was to determine if premorbid glenohumeral joint anatomy is better restored with a fixed- vs. variable-NSA prosthesis. METHODS A randomized controlled trial was performed including 50 patients with osteoarthritis indicated for primary anatomic TSA. Patients were randomized preoperatively to receive either a variable- (n = 26) or fixed-NSA (n = 24) prosthesis. Humeral neck cut in the variable-NSA group matched the patient's anatomic neck, with prosthetic NSA of 127.5°, 132.5°, and 137.5° available. Fixed-NSA cuts were made with an intramedullary guide of 132.5°. Preoperative and postoperative radiographs were evaluated for specific radiographic anatomic variables: NSA, head thickness, tuberosity-to-head height, head offset, articular arc, greater tuberosity offset, and center of rotation (COR). Postoperative radiographic criteria were compared between groups. RESULTS No differences were found between groups in demographics or preoperative radiographic measures. When comparing average difference in preoperative and postoperative measurements in the fixed-NSA group, the humeral head offset from the humeral shaft axis significantly decreased by 1.4 mm (P = .046), and the COR moved superiorly (3.0 mm, P = .002) without significant medialization or lateralization. In the variable angle group, humeral head offset decreased but did not reach significance (1.2 mm, P = .091), and the COR also moved superiorly (2.9 mm, P < .001) without significant medialization or lateralization. All remaining radiographic parameters did not significantly change from pre- to postoperative imaging. In comparing the fixed- and variable-NSA groups' net change from the premorbid measurements, no significant differences were found in tuberosity-to-head height, head offset, or COR position in both the horizontal and vertical planes. CONCLUSIONS Both fixed- and variable-NSA anatomic TSA humeral components demonstrate adequate restoration of premorbid anatomy radiographically.
Collapse
Affiliation(s)
| | - Manan S Patel
- Department of Orthopedic Surgery, Cooper Health, Cherry Hill, NJ, USA
| | - Kurt Stoll
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA
| | - Arjun M Singh
- College of Medicine, University of Illinois Chicago, Chicago, IL, USA
| | - Michael A Stone
- Department of Orthopaedic Surgery, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - John G Horneff
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Luke Austin
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA
| | - Mark D Lazarus
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
11
|
Long-term results of the uncemented resurfacing shoulder hemiarthroplasty (Global Conservative Anatomic Prosthesis). J Shoulder Elbow Surg 2022; 31:839-846. [PMID: 34592409 DOI: 10.1016/j.jse.2021.08.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 08/18/2021] [Accepted: 08/20/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Treatment with uncemented resurfacing shoulder hemiarthroplasty has proved to be viable for patients with end-stage osteoarthritis at short- and mid-term follow-up. This study was essential to determine whether those outcomes will endure. This study presents the long-term results of the Global Conservative Anatomic Prosthesis (CAP) uncemented resurfacing shoulder hemiarthroplasty (DePuy Synthes, Warsaw, IN, USA). METHODS All patients with a diagnosis of glenohumeral osteoarthritis and an intact and clinically sufficient rotator cuff who underwent uncemented resurfacing shoulder hemiarthroplasty between 2007 and 2009 were included. The data of all patients who completed the 10-year follow-up assessments were used for analysis. The visual analog scale pain score, Dutch version of the Simple Shoulder Test score, Constant score, Short Form 12 scores, and physical examination findings were evaluated preoperatively and postoperatively on an annual basis. All complications and revisions were documented. Radiographs were evaluated for loosening, luxation or subluxation, migration, and glenoid erosion. RESULTS Of 48 shoulders, 23 (48%, 18 women and 5 men) were available for the 10-year follow-up assessments and their data were used for analysis. The main reasons for dropout were revision (27%) and death (10%). The mean follow-up period of the remaining patients was 10.9 years (range, 9-13 years). The visual analog scale pain score (from 6.5 ± 2.1 to 0.7 ± 1.6, P < .001), Simple Shoulder Test (Dutch version) score (from 22% ± 22% to 79% ± 22%, P < .001), Constant score (from 40 ± 29 to 70 ± 8, P < .001), and Short Form 12 physical score (from 36 ± 7 to 41 ± 12, P = .001) improved significantly compared with preoperative scores. Revision surgery was performed in 13 of the initial 48 shoulders (27%). Most revisions were seen within 7 years postoperatively. CONCLUSION Two revisions have been performed in the mid-term to long term because of increased functional outcome scores and the absence of signs of loosening. Nevertheless, the high overall revision rate of 27% between short- and long-term follow-up reflects the need to limit the use of uncemented resurfacing shoulder hemiarthroplasty for the treatment of glenohumeral osteoarthritis.
Collapse
|
12
|
Luz GD, Cavalcanti AS, Ferreira J, Godoy E, Amaral MVG, Motta Filho GDR. Correlação entre posicionamento do implante das artroplastias parciais de recobrimento do ombro e os resultados funcionais. Rev Bras Ortop 2022; 57:480-487. [PMID: 35785124 PMCID: PMC9246527 DOI: 10.1055/s-0041-1729589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Accepted: 01/08/2021] [Indexed: 11/08/2022] Open
Abstract
Objective
The present study aimed to correlate functional outcomes and implant positioning in a case series of partial shoulder resurfacing arthroplasties.
Methods
A total of 25 patients were assessed for range of motion, functional outcome per the University of California at Los Angeles (UCLA) score and radiographic findings. Pre- and postoperative data were compared. In addition, patients were grouped according to the cervical-diaphyseal angle (CDA) determined by an anteroposterior radiography and to the retroversion angle (RVA) determined by an axillary radiography. A CDA from 130° to 140° and a RVA from 20° to 40° consisted in ideal positioning (anatomical standard). Data were analyzed using the Wilcoxon signed-rank test, analysis of variance (ANOVA) followed by the Kruskal-Wallis test or the Mann-Whitney test as appropriate.
Results
The mean follow-up time was 48.3 months (12 to 67 months). The postoperative functional score (31.5) was higher than the preoperative score (15.5) (
p
< 0.001). In 6 patients, the implant was in anatomical positioning, while implant positioning was considered “nonstandard” in 19 subjects. Seven patients had a CDA < 130°, and 14 patients had a CDA ranging from 130° to 140°; in addition, the CDA was > 140° in 4 subjects. The RVA was up to 20° in 15 patients and ranged from 20° to 40° in 10 subjects. Using these criteria to group patients, the postoperative clinical-functional parameters were not statistically different from the preoperative findings (
p
> 0.05).
Conclusion
Partial shoulder resurfacing results in significant postoperative functional recovery in patients with degenerative joint diseases. However, implant positioning assessed by CDA and RVA does not correlate with clinical-functional outcomes and, therefore, it is an inaccurate indicator of surgical success.
Level of Evidence IV; Case Series.
Collapse
Affiliation(s)
- Gilberto Daniel Luz
- Centro de Cirurgia do Ombro e Cotovelo, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| | - Amanda S. Cavalcanti
- Divisão de Pesquisa, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| | - Júlio Ferreira
- Centro de Cirurgia do Ombro e Cotovelo, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| | - Eduardo Godoy
- Centro de Cirurgia do Ombro e Cotovelo, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| | | | - Geraldo da R. Motta Filho
- Centro de Cirurgia do Ombro e Cotovelo, Instituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, RJ, Brasil
| |
Collapse
|
13
|
Cointat C, Raynier JL, Vasseur H, Lareyre F, Raffort J, Gauci MO, Boileau P. Short-term outcomes and survival of pyrocarbon hemiarthroplasty in the young arthritic shoulder. J Shoulder Elbow Surg 2022; 31:113-122. [PMID: 34280573 DOI: 10.1016/j.jse.2021.06.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 06/02/2021] [Accepted: 06/07/2021] [Indexed: 02/01/2023]
Abstract
HYPOTHESIS The purpose was to report the short-term outcomes and survival of hemiarthroplasty with a pyrocarbon head (HA-PYC) for the treatment of shoulder osteoarthritis in patients aged ≤ 60 years. We hypothesized that HA-PYC could be an alternative to hemi-metal (avoiding the risk of rapid glenoid erosion) and total shoulder arthroplasty (TSA) (avoiding the risk of rapid glenoid loosening) in an active patient population. METHODS Sixty-four consecutive patients (mean age, 53 years) who underwent HA-PYC for glenohumeral osteoarthritis were included. The primary outcome was revision to TSA or reverse shoulder arthroplasty. Secondary outcome measures included functional outcome scores; return to work and sports; and radiographic evaluation of humeral reconstruction quality using the "circle method" of Mears, as well as glenoid erosion severity and progression using the Sperling classification. Patients were reviewed and underwent radiography at an average follow-up of 33 months (range, 24-60 months). RESULTS At last follow-up, the rate of survival of the HA-PYC prosthesis was 92%. Revision was performed in 5 patients, with a mean delay of 24 months (range, 15-37 months): 1 conversion to TSA and 4 conversions to reverse shoulder arthroplasty. The Constant score and Subjective Shoulder Value increased from 36 points (range, 26-50 points) to 75 points (range, 69-81 points) and from 35% (range, 20%-50%) to 80% (range, 75%-90%), respectively (P < .001). Postoperatively, 91% of the patients (42 of 46) returned to work and 88% (15 of 17) returned to sport. The severity of preoperative and postoperative glenoid wear (Sperling grade 3 or 4) had no influence on the functional results. Patients who underwent associated concentric glenoid reaming (n = 23) had similar Constant scores and Subjective Shoulder Values (P = .95) to other patients and did not show more progression of glenoid wear. Nonanatomic reconstruction of the proximal humerus (center of rotation of the prosthesis > 3 mm from the anatomic center) occurred in 29% (18 of 62 patients) and was associated with significantly lower functional and subjective results, more complications (subscapularis insufficiency and/or symptomatic glenoid erosion), and a higher risk of revision. The additional 1.5-mm thickness of the metal disc under the pyrocarbon head was found to be the main reason for oversizing of the prosthetic head. CONCLUSION HA-PYC is a reliable procedure to treat shoulder osteoarthritis and allows return to work and sports in a young (≤60 years) and active patient population. The severity of glenoid bone erosion or the association with glenoid reaming does not affect functional outcomes and failure risk. By contrast, nonanatomic reconstruction of the proximal humerus after HA-PYC (because of humeral head oversizing) occurred in one-third of the cases and is associated with lower functional outcomes, as well as higher risks of complications and revision.
Collapse
Affiliation(s)
- Caroline Cointat
- Institut Universitaire Locomoteur et du Sport (IULS), Hôpital Pasteur 2, Université Côte d'Azur, Nice, France.
| | - Jean Luc Raynier
- Institut Universitaire Locomoteur et du Sport (IULS), Hôpital Pasteur 2, Université Côte d'Azur, Nice, France
| | | | | | | | - Marc Olivier Gauci
- Institut Universitaire Locomoteur et du Sport (IULS), Hôpital Pasteur 2, Université Côte d'Azur, Nice, France
| | | |
Collapse
|
14
|
Monir JG, Hao KA, Abeyewardene D, O'Keefe KJ, King JJ, Wright TW, Schoch BS. Extra-short humeral heads reduce glenohumeral joint overstuffing compared with short heads in anatomic total shoulder arthroplasty. JSES Int 2021; 6:209-215. [PMID: 35252915 PMCID: PMC8888178 DOI: 10.1016/j.jseint.2021.11.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Background Rotator cuff tears and glenoid loosening remain the two most common causes for revision after anatomic total shoulder arthroplasty. Oversizing of the humeral head leads to increased contact force across the glenohumeral joint and is hypothesized to contribute to clinical and radiographic failure. The purpose of this study is to compare the rate of radiographic overstuffing between standard short humeral heads and newer extra-short heads with decreased lateral offset. Methods Fifty-five consecutive anatomic total shoulder arthroplasties performed using extra-short humeral heads were retrospectively reviewed and compared with age- and sex-matched controls receiving standard short heads. A total of 110 postoperative radiographs were analyzed using the Iannotti's perfect circle method to compare the prosthesis' center of rotation (COR) with the native humeral head COR. A difference in the COR of >3.0 mm was considered malpositioned. Malpositioning medially was considered overstuffed, and malpositioning laterally was considered understuffed. The direction of displacement of malpositioned prostheses was categorized using a quadrant system. Furthermore, we used a novel method to evaluate medial and superior overstuffing by measuring the displacement between the anatomic and prosthetic head positions along perpendicular axes. Results Using the Iannotti's perfect circle method, 56% of heads were malpositioned. Overstuffing occurred more frequently with short heads compared with extra-short heads (47% vs. 4%, P < .001). Conversely, understuffing occurred more frequently with extra-short heads (47% vs. 15%, P = .001). Malpositioned extra-short heads were most frequently placed in the inferomedial quadrant (93% vs. 24%, P < .001), whereas malpositioned short heads were most commonly placed in the superomedial quadrant (56% vs. 7%, P < .001). Our novel measurement method demonstrated that extra-short heads reduced medial overstuffing (2.8 ± 2.8 mm vs. 0.3 ± 2.0 mm, P < .001). Both extra-short and short heads had similar rates of superior malpositioning (1.6 ± 2.2 mm vs. 1.4 ± 1.5 mm, P = .683). Conclusion Routine use of extra-short humeral head sizes reduces the rate of medial glenohumeral joint overstuffing but not superior malpositioning. This is hypothesized to improve clinical outcomes, but future studies are needed to assess the relationship between improved humeral head fit and clinical outcomes.
Collapse
Affiliation(s)
- Joseph G. Monir
- Department Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Kevin A. Hao
- University of Florida College of Medicine, Gainesville, FL, USA
| | - Dilhan Abeyewardene
- Orthopaedic Care Specialists, Hand & Upper Extremity Surgery, North Palm Beach, FL, USA
| | | | - Joseph J. King
- Department Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Thomas W. Wright
- Department Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA
| | - Bradley S. Schoch
- Department of Orthopedics, Mayo Clinic, Jacksonville, FL, USA
- Corresponding author: Bradley S. Schoch, MD, 4500 San Pablo Rd, Jacksonville, FL 32224, USA.
| |
Collapse
|
15
|
Cavanagh J, Lockhart J, Langohr GDG, Johnson JA, Athwal GS. A comparison of patient-specific instrumentation to navigation for conducting humeral head osteotomies during shoulder arthroplasty. JSES Int 2021; 5:875-880. [PMID: 34505099 PMCID: PMC8411057 DOI: 10.1016/j.jseint.2021.05.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background The humeral head osteotomy during shoulder arthroplasty influences humeral component height, version and possibly neck-shaft angle. These parameters all potentially influence outcomes of anatomic and reverse shoulder replacement to a variable degree. Patient-specific guides and navigation have been studied and utilized clinically for glenoid component placement. Little, however, has been done to evaluate these techniques for humeral head osteotomies. The purpose of this study, therefore, was to evaluate the use of patient-specific guides and surgical navigation for executing a planned humeral head osteotomy. Methods The DICOM images of 10 shoulder computed tomography scans (5 normal and 5 osteoarthritic) were used to print 3D polylactic models of the humerus. Each model was duplicated, such that there were 2 identical groups of 10 models. After preoperative planning of a humeral head osteotomy, Group 1 underwent osteotomy via a patient-specific guide, while group 2 underwent a real time navigated osteotomy with an optically tracked sagittal saw. The cut height (millimeters), version (degrees) and neck-shaft angle (degrees) were recorded and statistically compared between groups. Results There were no statistically significant differences between patient-specific guides and navigation for osteotomy cut height (P = .45) and humeral version (P = .059). Navigation, however, resulted in significantly less neck-shaft angle error than the patient specific guides (P = .023). Subgroup analysis of the osteoarthritic cases showed statistical significance for navigation resulting in less version error than the patient specific guides (P = .048). Conclusion No significant differences were found between patient specific guides and navigation for recreation of the preoperatively planned humeral head cut height and version. Neck-shaft angle, however, had significantly less deviation from the preoperative plan when conducted with navigation.
Collapse
Affiliation(s)
- Joseph Cavanagh
- Investigations performed at the Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - Jason Lockhart
- Investigations performed at the Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - G Daniel G Langohr
- Investigations performed at the Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - James A Johnson
- Investigations performed at the Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - George S Athwal
- Investigations performed at the Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| |
Collapse
|
16
|
Chillemi C, Paglialunga C, De Giorgi G, Proietti R, Carli S, Damo M. Outcome and revision rate of uncemented humeral head resurfacing: Mid-term follow-up study. World J Orthop 2021; 12:403-411. [PMID: 34189078 PMCID: PMC8223723 DOI: 10.5312/wjo.v12.i6.403] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 03/15/2021] [Accepted: 05/22/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Glenohumeral osteoarthritis (OA) is a common cause of pain and disability affecting nearly a third of the world’s population over 60 years of age. As in other joints, shoulder arthroplasty appears to be the most effective treatment. The implant design has evolved during time transitioning to shorter humeral stem lengths or even stemless components.
AIM To evaluate the medium-term outcome and survival of a cementless humeral head resurfacing (HHR) in a group of patients affected with OA or avascular necrosis.
METHODS This is a retrospective study of prospectively collected data using HHR in 23 patients (15 female and 8 male) after a 7.4 year follow-up. The collected data included clinical and radiographical evaluation. The Constant score, the visual analogue scale, and a clinical evaluation of range of motion were registered pre- and postoperatively. Fifteen patients affected with OA (2 cases of mild, 6 moderate, and 7 severe) and 10 with avascular necrosis (stage III according to Cruess classification) were enrolled. X-rays were evaluated to detect loosening signs, degenerative changes, and superior humeral head migration. Magnetic resonance preoperatively was also performed to assess the rotator cuff status. Tendon integrity was mandatory to implant the HHR.
RESULTS In total, 19 patients (21 shoulders) completed the follow-up. Data on 4 shoulders, in 4 patients, were lost because of prosthesis failure. The global revision rate was 16%. A statistically significant improvement in the mean Constant score, visual analogue scale, and range of motion have been reported. No signs of loosening were registered, while in 12 cases a glenoid erosion was found. The osteophytes appeared 7 times on the humeral side and 12 on the glenoid. Superior humeral migration was recorded in only 1 case.
CONCLUSION HHR remains a reasonable option in patients with an intact rotator cuff for the treatment of OA and avascular necrosis.
Collapse
Affiliation(s)
- Claudio Chillemi
- Department of Orthopaedics and Traumatology, Istituto Chirurgico Ortopedico Traumatologico, Latina 04100, Lazio, Italy
| | - Carlo Paglialunga
- Department of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, ICOT, Latina 04100, Lazio, Italy
| | - Greta De Giorgi
- Department of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, ICOT, Latina 04100, Lazio, Italy
| | - Riccardo Proietti
- Department of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, ICOT, Latina 04100, Lazio, Italy
| | - Stefano Carli
- Department of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, ICOT, Latina 04100, Lazio, Italy
| | - Marco Damo
- Department of Anatomical, Histological, Forensic Medicine and Orthopaedics Sciences, Sapienza University of Rome, ICOT, Latina 04100, Lazio, Italy
| |
Collapse
|
17
|
Tsitlakidis S, Doll J, Westhauser F, Wolf M, Hetto P, Maier M, Sowa B. Promising results after hemi-shoulder arthroplasty using pyrolytic carbon heads in young and middle-aged patients. Orthop Traumatol Surg Res 2021; 107:102896. [PMID: 33753266 DOI: 10.1016/j.otsr.2021.102896] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 10/03/2020] [Accepted: 10/30/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The objective of this prospective cohort study was the assessment of short-term outcome results of shoulder hemiarthroplasty (HA) using pyrolytic carbon (PC) heads. PC has been introduced as a new material to avoid surgical revision due to glenoid erosion after HA. Glenoid erosion due to the use of metallic heads is known to reduce durability. HYPOTHESIS HA using PC heads shows comparable or better radiographic and clinical outcome compared to the conventional HA using metallic heads in the short-term. PATIENTS AND METHODS This study was conducted as a single center prospective cohort follow-up study including a total number of 16 consecutive HA with PC heads. Inclusion criteria were indication for HA, an intact rotator cuff, no proximal humeral fractures in patient's history and age>18years. Mean age at the time of arthroplasty was 52.8±10.8years. The mean follow-up was 24.3±8.1months. Baseline and follow-up Numeric Rating Scale (NRS), Constant Scores (CS), Range of Motion (ROM) and radiographs were assessed. RESULTS At a mean follow-up of 24.3months the mean CS (p<0.001), mean NRS (p<0.001) and mean ROM (p<0.05) improved statistically significant. Subgroup analysis revealed no differences between subgroups (sex, age, diagnosis, and handedness). Survival rate was high (94.1%). One periprosthetic fracture occurred as the only complication during follow-up. Radiographs showed glenoid erosion in one case and subacromial space reduction in two cases. DISCUSSION PC heads in HA show satisfying short-term results at a mean follow-up of two years, which are comparable to those of conventional HA. The clinical improvements were highly significant with good implant survival. However, long-term follow-up results are necessary, especially compared to conventional HA. LEVEL OF EVIDENCE IV; observational therapeutic cohort study.
Collapse
Affiliation(s)
- Stefanos Tsitlakidis
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Julian Doll
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Fabian Westhauser
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Matthias Wolf
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Pit Hetto
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany
| | - Michael Maier
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany; Schwaebisches Gelenkzentrum Stuttgart, Hohenheimer Str. 91, 70184 Stuttgart, Germany
| | - Boris Sowa
- Clinic of Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstr. 200a, 69118 Heidelberg, Germany.
| |
Collapse
|
18
|
Does computerized CT-based 3D planning of the humeral head cut help to restore the anatomy of the proximal humerus after stemless total shoulder arthroplasty? J Shoulder Elbow Surg 2021; 30:e309-e316. [PMID: 32950671 DOI: 10.1016/j.jse.2020.08.045] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 08/19/2020] [Accepted: 08/24/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Restoration of proximal humeral anatomy (RPHA) after total shoulder arthroplasty (TSA) has been shown to result in better clinical outcomes than is the case in nonanatomic humeral reconstruction. Preoperative virtual planning has mainly focused on glenoid component placement. Such planning also has the potential to improve anatomic positioning of the humeral head by more accurately guiding the humeral head cut and aid in the selection of anatomic humeral component sizing. It was hypothesized that the use of preoperative 3-dimensional (3D) planning helps to reliably achieve RPHA after stemless TSA. METHODS One hundred consecutive stemless TSA (67 males, 51 right shoulder, mean age of 62 ±9.4 years) were radiographically assessed using pre- and postoperative standardized anteroposterior radiographs. The RPHA was measured with the so-called circle method described by Youderian et al. We measured deviation from the premorbid center of rotation (COR), and more than 3 mm was considered as minimal clinically important difference. Additionally, pre- and postoperative humeral head diameter (HHD), head-neck angle (HNA), and humeral head height (HHH) were measured to assess additional geometrical risk factors for poor RPHA. RESULTS The mean distance from of the premorbid to the implanted head COR was 4.3 ± 3.1 mm. Thirty-five shoulders (35%) showed a deviation of less than 3 mm (mean 1.9 ±1.1) and 65 shoulders (65%) a deviation of ≥3 mm (mean 8.0 ± 3.7). Overstuffing was the main reason for poor RPHA (88%). The level of the humeral head cut was responsible for overstuffing in 46 of the 57 overstuffed cases. The preoperative HHD, HHH, and HNA were significantly larger, higher, and more in valgus angulation in the group with accurate RPHA compared with the group with poor RPHA (HHD of 61.1 mm ± 4.4 vs. 55.9 ± 6.6, P < .001; HHH 8.6±2.2 vs. 7.6±2.6, P = .026; and varus angulation of 134.7° ±6.4° vs. 131.0° ±7.91, P = .010). CONCLUSION Restoration of proximal humeral anatomy after stemless TSA using computed tomography (CT)-based 3D planning was not precise. A poorly performed humeral head cut was the main reason for overstuffing, which was seen in 88% of the cases with inaccurate RPHA. Preoperative small HHD, low HHH, and varus-angulated HNA are risk factors for poor RPHA after stemless TSA.
Collapse
|
19
|
Wegmann K, Hackl M, Leschinger T, Burkhart KJ, Müller LP. Overlengthening of the radial column in radial head replacement: a review of the literature and presentation of a classification system. Arch Orthop Trauma Surg 2021; 141:1525-1539. [PMID: 33057805 PMCID: PMC8354917 DOI: 10.1007/s00402-020-03619-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Accepted: 09/30/2020] [Indexed: 11/26/2022]
Abstract
BACKGROUND Radial head arthroplasty is a common procedure in elbow surgery. It has been shown to be of benefit for the patients, but there also are relevant complications that should be prevented if possible. One significant complication is overlengthening of the radial head prosthesis. In overlengthening, the head of the prosthesis overextends the physiological level of the native radial head and leads to overcompression in the radiohumeral joint. Rapid erosion and arthritic changes may then impede the clinical outcome. The incidence of overlengthening is not precisely known, but estimations range to up to 20% of all implanted prostheses. METHODS The present review discusses the available body of literature on overlengthening and lines out a classification system that may be used to guide treatment algorithms. The classification is based on the personal experiences of the author during their clinical practice. RESULTS In low-grade overlengthening (type I) conservative treatment can be an option. In Types II-IV usually revision surgery is needed. Depending on the state of the capitulum and joint stability, it is possible re-implant a prosthesis, or rely on implant removal alone. DISCUSSION The present review aimed at shedding light into overlengthening as a complication radial head replacement and to help identify and treat it.
Collapse
Affiliation(s)
- K Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - M Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - T Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | | | - L P Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany
| |
Collapse
|