1
|
Advances in the Development of Positron Emission Tomography Tracers for Improved Detection of Differentiated Thyroid Cancer. Cancers (Basel) 2024; 16:1401. [PMID: 38611079 PMCID: PMC11010999 DOI: 10.3390/cancers16071401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 03/25/2024] [Accepted: 03/28/2024] [Indexed: 04/14/2024] Open
Abstract
Thyroid cancer poses a significant challenge in clinical management, necessitating precise diagnostic tools and treatment strategies for optimal patient outcomes. This review explores the evolving field of radiotracers in the diagnosis and management of thyroid cancer, focusing on prostate-specific membrane antigen (PSMA)-based radiotracers, fibroblast activation protein inhibitor (FAPI)-based radiotracers, Arg-Gly-Asp (RGD)-based radiotracers, and 18F-tetrafluoroborate (18F-TFB). PSMA-based radiotracers, initially developed for prostate cancer imaging, have shown promise in detecting thyroid cancer lesions; however, their detection rate is lower than 18F-FDG PET/CT. FAPI-based radiotracers, targeting fibroblast activation protein highly expressed in tumors, offer potential in the detection of lymph nodes and radioiodine-resistant metastases. RGD-based radiotracers, binding to integrin αvβ3 found on tumor cells and angiogenic blood vessels, demonstrate diagnostic accuracy in detecting radioiodine-resistant thyroid cancer metastases. 18F-TFB emerges as a promising PET tracer for imaging of lymph node metastases and recurrent DTC, offering advantages over traditional methods. Overall, these radiotracers show promise in enhancing diagnostic accuracy, patient stratification, and treatment selection in differentiated thyroid cancer, warranting further research and clinical validation. Given the promising staging capabilities of 18F-TFB and the efficacy of FAP-targeting tracers in advanced, potentially dedifferentiated cases, continued investigation in these domains is justified.
Collapse
|
2
|
Diagnostic Performance of [ 18F]TFB PET/CT Compared with Therapeutic Activity [ 131I]Iodine SPECT/CT and [ 18F]FDG PET/CT in Recurrent Differentiated Thyroid Carcinoma. J Nucl Med 2024; 65:192-198. [PMID: 38164565 PMCID: PMC10858375 DOI: 10.2967/jnumed.123.266513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 11/01/2023] [Indexed: 01/03/2024] Open
Abstract
[18F]tetrafluoroborate ([18F]TFB) is an emerging PET tracer with excellent properties for human sodium iodide symporter (NIS)-based imaging in patients with differentiated thyroid cancer (DTC). The aim of this study was to compare [18F]TFB PET with high-activity posttherapeutic [131I]iodine whole-body scintigraphy and SPECT/CT in recurrent DTC and with [18F]FDG PET/CT in suspected dedifferentiation. Methods: Twenty-six patients treated with high-activity radioactive [131I]iodine therapy (range, 5.00-10.23 GBq) between May 2020 and November 2022 were retrospectively included. Thyroid-stimulating hormone was stimulated by 2 injections of recombinant thyroid-stimulating hormone (0.9 mg) 48 and 24 h before therapy. Before treatment, all patients underwent [18F]TFB PET/CT 40 min after injection of a median of 321 MBq of [18F]TFB. To study tracer kinetics in DTC lesions, 23 patients received an additional scan at 90 min. [131I]iodine therapeutic whole-body scintigraphy and SPECT/CT were performed at a median of 3.8 d after treatment. Twenty-five patients underwent additional [18F]FDG PET. Two experienced nuclear medicine physicians evaluated all imaging modalities in consensus. Results: A total of 62 suspected lesions were identified; of these, 30 lesions were [131I]iodine positive, 32 lesions were [18F]TFB positive, and 52 were [18F]FDG positive. Three of the 30 [131I]iodine-positive lesions were retrospectively rated as false-positive iodide uptake. Tumor-to-background ratio measurements at the 40- and 90-min time points were closely correlated (e.g., for the tumor-to-background ratio for muscle, the Pearson correlation coefficient was 0.91; P < 0.001; n = 49). We found a significant negative correlation between [18F]TFB uptake and [18F]FDG uptake as a potential marker for dedifferentiation (Pearson correlation coefficient, -0.26; P = 0.041; n = 62). Conclusion: Pretherapeutic [18F]TFB PET/CT may help to predict the positivity of recurrent DTC lesions on [131I]iodine scans. Therefore, it may help in the selection of patients for [131I]iodine therapy. Future prospective trials for iodine therapy guidance are warranted. Lesion [18F]TFB uptake seems to be inversely correlated with [18F]FDG uptake and therefore might serve as a dedifferentiation marker in DTC.
Collapse
|
3
|
Applications of ion chromatography in urine analysis: A review. J Chromatogr A 2023; 1706:464231. [PMID: 37517316 DOI: 10.1016/j.chroma.2023.464231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/17/2023] [Accepted: 07/19/2023] [Indexed: 08/01/2023]
Abstract
Ion chromatography (IC) plays a crucial role in urine analysis for diverse medical diagnoses. This paper reviews a comprehensive investigation into urine pretreatment techniques, as well as the design and development of IC systems for the measurement of various chemicals. Prior to analysis, urine samples commonly undergo pretreatment procedures such as dilution, filtration, purification, and concentration. These steps effectively eliminate interfering factors and facilitate the accurate and sensitive analysis of ultra-trace components. To separate and quantify different chemical elements or ions present in urine, a range of homemade or commercially available columns coupled with various detectors were employed. This study focuses on the analysis of chemicals such as heavy metals, halogens, pesticides, drugs, and other essential or toxic substances by IC methods.
Collapse
|
4
|
Complementary early-phase magnetic particle imaging and late-phase positron emission tomography reporter imaging of mesenchymal stem cells in vivo. NANOSCALE 2023; 15:3408-3418. [PMID: 36722918 DOI: 10.1039/d2nr03684c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Stem cell-based therapies have demonstrated significant potential in clinical applications for many debilitating diseases. The ability to non-invasively and dynamically track the location and viability of stem cells post administration could provide important information on individual patient response and/or side effects. Multi-modal cell tracking provides complementary information that can offset the limitations of a single imaging modality to yield a more comprehensive picture of cell fate. In this study, mesenchymal stem cells (MSCs) were engineered to express human sodium iodide symporter (NIS), a clinically relevant positron emission tomography (PET) reporter gene, as well as labeled with superparamagnetic iron oxide nanoparticles (SPIOs) to allow for detection with magnetic particle imaging (MPI). MSCs were additionally engineered with a preclinical bioluminescence imaging (BLI) reporter gene for comparison of BLI cell viability data to both MPI and PET data over time. MSCs were implanted into the hind limbs of immunocompromised mice and imaging with MPI, BLI and PET was performed over a 30-day period. MPI showed sensitive detection that steadily declined over the 30-day period, while BLI showed initial decreases followed by later rapid increases in signal. The PET signal of MSCs was significantly higher than the background at later timepoints. Early-phase imaging (day 0-9 post MSC injections) showed correlation between MPI and BLI data (R2 = 0.671), while PET and BLI showed strong correlation for late-phase (day 10-30 post MSC injections) imaging timepoints (R2 = 0.9817). We report the first use of combined MPI and PET for cell tracking and show the complementary benefits of MPI for sensitive detection of MSCs early after implantation and PET for longer-term measurements of cell viability.
Collapse
|
5
|
High molar activity [ 18F]tetrafluoroborate synthesis for sodium iodide symporter imaging by PET. EJNMMI Radiopharm Chem 2022; 7:32. [PMID: 36512196 PMCID: PMC9747990 DOI: 10.1186/s41181-022-00185-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 12/02/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Sodium iodide symporter (NIS) imaging by positron emission tomography (PET) is gaining traction in nuclear medicine, with an increasing number of human studies being published using fluorine-18 radiolabelled tetrafluoroborate ([18F]TFB). Clinical success of any radiotracer relies heavily on its accessibility, which in turn depends on the availability of robust radiolabelling procedures providing a radiotracer in large quantities and of high radiopharmaceutical quality. RESULTS Here we publish an improved radiolabelling method and quality control procedures for high molar activity [18F]TFB. The use of ammonium hydroxide for [18F]fluoride elution, commercially available boron trifluoride-methanol complex dissolved in acetonitrile as precursor and removal of unreacted [18F]fluoride on Florisil solid-phase extraction cartridges resulted in the reliable production of [18F]TFB on SYNTHRA and TRACERLAB FXFN automated synthesizers with radiochemical yields in excess of 30%, radiochemical purities in excess of 98% and molar activities in the range of 34-217 GBq/µmol at the end of synthesis. PET scanning of a mouse lung tumour model carrying a NIS reporter gene rendered images of high quality and improved sensitivity. CONCLUSIONS A novel automated radiosynthesis procedure for [18F]tetrafluoroborate has been developed that provides the radiotracer with high molar activity, suitable for preclinical imaging of NIS reporter gene.
Collapse
|
6
|
Thyroid functional and molecular imaging. Presse Med 2022; 51:104116. [PMID: 35124101 DOI: 10.1016/j.lpm.2022.104116] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 12/02/2021] [Accepted: 01/28/2022] [Indexed: 12/16/2022] Open
Abstract
Radioiodine uptake (RAIU) test with iodine-123 (Na[123I]I) or iodine-131 (Na[131I]I) enables accurate evaluation and quantification of iodine uptake and kinetics within thyroid cells. Thyroid Scintigraphy (TS) employing Na[123I]I or 99mTc-pertechnetate (Na[99mTc]TcO4) provides information regarding the function and topographical distribution of thyroid cells activity, including detection and localization of ectopic thyroid tissue. Destructive thyrotoxicosis is characterized by low RAIU with scintigraphically reduced radiotracer activity in the thyroid tissue, while productive thyrotoxicosis (i.e. hyperthyroidism "stricto sensu") is characterized by high RAIU with scintigraphically diffuse (i.e. Graves' Disease, GD and diffuse thyroid autonomy) or focal (i.e. autonomously functioning thyroid nodules, AFTN) overactivity. Accordingly, RAIU and/or TS are widely used to differentiate different causes of thyrotoxicosis. In addition, several radiopharmaceuticals are also available to help differentiate benign from malignant thyroid nodules and inform clinical decision-making: scintigraphic identification of AFTNs obviate fine-needle aspiration (FNA) biopsy, and [99mTc]Tc-hexakis-(2‑methoxy-2-isobutyl isonitrile ([99mTc]Tc-MIBI) and/or 18F-fluoro-d-glucose ([18F]FDG) may complement the work-up of cytologically indeterminate "cold" nodules for reducing the need for diagnostic lobectomies/thyroidectomies. Finally, RAIU studies are also useful for calculating the administered therapeutic activity of Na[131I]I to treat hyperthyroidism and euthyroid multinodular goiter. All considered, thyroid molecular imaging allows functional characterization of different thyroid diseases, even before clinical symptoms become manifest, and remains integral to the management of such conditions. Our present paper summarizes basic concepts, clinical applications, and potential developments of thyroid molecular imaging in patients affected by thyrotoxicosis and thyroid nodules.
Collapse
|
7
|
Clinical activity of single-dose systemic oncolytic VSV virotherapy in patients with relapsed refractory T-cell lymphoma. Blood Adv 2022; 6:3268-3279. [PMID: 35175355 PMCID: PMC9198941 DOI: 10.1182/bloodadvances.2021006631] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 01/25/2022] [Indexed: 12/14/2022] Open
Abstract
Clinical success with intravenous (IV) oncolytic virotherapy (OV) has to-date been anecdotal. We conducted a phase 1 clinical trial of systemic OV and investigated the mechanisms of action in responding patients. A single IV dose of vesicular stomatitis virus (VSV) interferon-β (IFN-β) with sodium iodide symporter (NIS) was administered to patients with relapsed/refractory hematologic malignancies to determine safety and efficacy across 4 dose levels (DLs). Correlative studies were undertaken to evaluate viremia, virus shedding, virus replication, and immune responses. Fifteen patients received VSV-IFNβ-NIS. Three patients were treated at DL1 through DL3 (0.05, 0.17, and 0.5 × 1011 TCID50), and 6 were treated at DL4 (1.7 × 1011 TCID50) with no dose-limiting toxicities. Three of 7 patients with T-cell lymphoma (TCL) had responses: a 3-month partial response (PR) at DL2, a 6-month PR, and a complete response (CR) ongoing at 20 months at DL4. Viremia peaked at the end of infusion, g was detected. Plasma IFN-β, a biomarker of VSV-IFNβ-NIS replication, peaked between 4 hours and 48 hours after infusion. The patient with CR had robust viral replication with increased plasma cell-free DNA, high peak IFN-β of 18 213 pg/mL, a strong anti-VSV neutralizing antibody response, and increased numbers of tumor reactive T-cells. VSV-IFNβ-NIS as a single agent was effective in patients with TCL, resulting in durable disease remissions in heavily pretreated patients. Correlative analyses suggest that responses may be due to a combination of direct oncolytic tumor destruction and immune-mediated tumor control. This trial is registered at www.clinicaltrials.gov as #NCT03017820.
Collapse
|
8
|
The sodium iodide symporter (NIS) as theranostic gene: its emerging role in new imaging modalities and non-viral gene therapy. EJNMMI Res 2022; 12:25. [PMID: 35503582 PMCID: PMC9065223 DOI: 10.1186/s13550-022-00888-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 03/11/2022] [Indexed: 01/14/2023] Open
Abstract
Cloning of the sodium iodide symporter (NIS) in 1996 has provided an opportunity to use NIS as a powerful theranostic transgene. Novel gene therapy strategies rely on image-guided selective NIS gene transfer in non-thyroidal tumors followed by application of therapeutic radionuclides. This review highlights the remarkable progress during the last two decades in the development of the NIS gene therapy concept using selective non-viral gene delivery vehicles including synthetic polyplexes and genetically engineered mesenchymal stem cells. In addition, NIS is a sensitive reporter gene and can be monitored by high resolution PET imaging using the radiotracers sodium [124I]iodide ([124I]NaI) or [18F]tetrafluoroborate ([18F]TFB). We performed a small preclinical PET imaging study comparing sodium [124I]iodide and in-house synthesized [18F]TFB in an orthotopic NIS-expressing glioblastoma model. The results demonstrated an improved image quality using [18F]TFB. Building upon these results, we will be able to expand the NIS gene therapy approach using non-viral gene delivery vehicles to target orthotopic tumor models with low volume disease, such as glioblastoma. Trial registration not applicable.
Collapse
|
9
|
Personalized Diagnosis in Differentiated Thyroid Cancers by Molecular and Functional Imaging Biomarkers: Present and Future. Diagnostics (Basel) 2022; 12:diagnostics12040944. [PMID: 35453992 PMCID: PMC9030409 DOI: 10.3390/diagnostics12040944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 04/04/2022] [Accepted: 04/08/2022] [Indexed: 11/17/2022] Open
Abstract
Personalized diagnosis can save unnecessary thyroid surgeries, in cases of indeterminate thyroid nodules, when clinicians tend to aggressively treat all these patients. Personalized diagnosis benefits from a combination of imagery and molecular biomarkers, as well as artificial intelligence algorithms, which are used more and more in our timeline. Functional imaging diagnosis such as SPECT, PET, or fused images (SPECT/CT, PET/CT, PET/MRI), is exploited at maximum in thyroid nodules, with a long history in the past and a bright future with many suitable radiotracers that could properly contribute to diagnosing malignancy in thyroid nodules. In this way, patients will be spared surgery complications, and apparently more expensive diagnostic workouts will financially compensate each patient and also the healthcare system. In this review we will summarize essential available diagnostic tools for malignant and benignant thyroid nodules, beginning with functional imaging, molecular analysis, and combinations of these two and other future strategies, including AI or NIS targeted gene therapy for thyroid carcinoma diagnosis and treatment as well.
Collapse
|
10
|
Molecular Imaging and Theragnostics of Thyroid Cancers. Cancers (Basel) 2022; 14:cancers14051272. [PMID: 35267580 PMCID: PMC8909041 DOI: 10.3390/cancers14051272] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 02/22/2022] [Accepted: 02/25/2022] [Indexed: 02/06/2023] Open
Abstract
Molecular imaging plays an important role in the evaluation and management of different thyroid cancer histotypes. The existing risk stratification models can be refined, by incorporation of tumor-specific molecular markers that have theranostic power, to optimize patient-specific (individualized) treatment decisions. Molecular imaging with varying radioisotopes of iodine (i.e., 131I, 123I, 124I) is an indispensable component of dynamic and theragnostic risk stratification of differentiated carcinoma (DTC) while [18F]F-fluorodeoxyglucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) helps in addressing disease aggressiveness, detects distant metastases, and risk-stratifies patients with radioiodine-refractory DTC, poorly differentiated and anaplastic thyroid cancers. For medullary thyroid cancer (MTC), a neuroendocrine tumor derived from thyroid C-cells, [18F]F-dihydroxyphenylalanine (6-[18F]FDOPA) PET/CT and/or [18F]FDG PET/CT can be used dependent on serum markers levels and kinetics. In addition to radioiodine therapy for DTC, some theragnostic approaches are promising for metastatic MTC as well. Moreover, new redifferentiation strategies are now available to restore uptake in radioiodine-refractory DTC while new theragnostic approaches showed promising preliminary results for advanced and aggressive forms of follicular-cell derived thyroid cancers (i.e., peptide receptor radiotherapy). In order to help clinicians put the role of molecular imaging into perspective, the appropriate role and emerging opportunities for molecular imaging and theragnostics in thyroid cancer are discussed in our present review.
Collapse
|
11
|
Whole-Body Imaging to Assess Cell-Based Immunotherapy: Preclinical Studies with an Update on Clinical Translation. Mol Imaging Biol 2021; 24:235-248. [PMID: 34816284 PMCID: PMC8983636 DOI: 10.1007/s11307-021-01669-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 10/12/2021] [Accepted: 10/13/2021] [Indexed: 11/28/2022]
Abstract
In the past decades, immunotherapies against cancers made impressive progress. Immunotherapy includes a broad range of interventions that can be separated into two major groups: cell-based immunotherapies, such as adoptive T cell therapies and stem cell therapies, and immunomodulatory molecular therapies such as checkpoint inhibitors and cytokine therapies. Genetic engineering techniques that transduce T cells with a cancer-antigen-specific T cell receptor or chimeric antigen receptor have expanded to other cell types, and further modulation of the cells to enhance cancer targeting properties has been explored. Because cell-based immunotherapies rely on cells migrating to target organs or tissues, there is a growing interest in imaging technologies that non-invasively monitor transferred cells in vivo. Here, we review whole-body imaging methods to assess cell-based immunotherapy using a variety of examples. Following a review of preclinically used cell tracking technologies, we consider the status of their clinical translation.
Collapse
|
12
|
Nuclear imaging for immune cell tracking in vivo – Comparison of various cell labeling methods and their application. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
13
|
Abstract
Reporter gene imaging (RGI) can accelerate development timelines for gene and viral therapies by facilitating rapid and noninvasive in vivo studies to determine the biodistribution, magnitude, and durability of viral gene expression and/or virus infection. Functional molecular imaging systems used for this purpose can be divided broadly into deep-tissue and optical modalities. Deep-tissue modalities, which can be used in animals of any size as well as in human subjects, encompass single photon emission computed tomography (SPECT), positron emission tomography (PET), and functional/molecular magnetic resonance imaging (f/mMRI). Optical modalities encompass fluorescence, bioluminescence, Cerenkov luminescence, and photoacoustic imaging and are suitable only for small animal imaging. Here we discuss the mechanisms of action and relative merits of currently available reporter gene systems, highlighting the strengths and weaknesses of deep tissue versus optical imaging systems and the hardware/reagents that are used for data capture and processing. In light of recent technological advances, falling costs of imaging instruments, better availability of novel radioactive and optical tracers, and a growing realization that RGI can give invaluable insights across the entire in vivo translational spectrum, the approach is becoming increasingly essential to facilitate the competitive development of new virus- and gene-based drugs.
Collapse
|
14
|
Can the function of the tubarial glands be evaluated using [ 99mTc]pertechnetate SPECT/CT, [ 18F]FDG PET/CT, and [ 11C]methionine PET/CT? EJNMMI Res 2021; 11:34. [PMID: 33788026 PMCID: PMC8012434 DOI: 10.1186/s13550-021-00779-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Accepted: 03/22/2021] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The tubarial glands (TGs) are recently reported as newly found salivary gland structures that can be organs at risk predominantly localized in the tori tubarius in the nasopharynx using prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT). The aims of this study were to analyze uptake in the TGs compared with that in the other salivary glands and palatine tonsils using [99mTc]pertechnetate SPECT/CT, [18F]FDG PET/CT, and [11C]methionine PET/CT and to confirm whether these three imaging modalities are useful in evaluating the physiological function of the TGs. Twelve and 130 patients, who underwent [99mTc]pertechnetate SPECT/CT and [18F]FDG/[11C]methionine PET/CT, respectively, were retrospectively included. [99mTc]pertechnetate uptake in the tori tubarius was visually assessed and semiquantitatively compared with that in the background, parotid salivary glands (PSGs), submandibular salivary glands (SmSGs), and sublingual salivary glands (SlSGs). Correlations of [18F]FDG and [11C]methionine uptakes in the tori tubarius with those in the other three salivary glands and palatine tonsils were analyzed. RESULTS [99mTc]pertechnetate uptake in the tori tubarius was invisible and was not significantly higher than that in the background. Both [18F]FDG and [11C]methionine uptakes in the tori tubarius were correlated with that in the palatine tonsils (r = 0.56, p < 0.0001; r = 0.48, p < 0.0001, respectively). [18F]FDG uptake in the tori tubarius was not positively correlated with that in the PSGs, SmSGs, and SlSGs (r = - 0.19, p = 0.03; r = - 0.02, p = 0.81; r = 0.12, p = 0.17, respectively). [11C]methionine uptake in the tori tubarius was correlated with that in the SmSGs and SlSGs (r = 0.24, p = 0.01; r = 0.32, p < 0.01, respectively), but not with that in the PSGs (r = 0.16, p = 0.08). CONCLUSIONS The TGs were undetectable on [99mTc]pertechnetate SPECT/CT. Both [18F]FDG and [11C]methionine uptakes in the tori tubarius were clearly affected by that in the palatine tonsils and was little related to that in the other salivary glands. Therefore, it seems difficult to evaluate the physiological function of the TGs as salivary glands using [99mTc]pertechnetate SPECT/CT, [18F]FDG PET/CT, and [11C]methionine PET/CT imaging.
Collapse
|
15
|
The chemical tool-kit for molecular imaging with radionuclides in the age of targeted and immune therapy. Cancer Imaging 2021; 21:18. [PMID: 33516256 PMCID: PMC7847158 DOI: 10.1186/s40644-021-00385-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 01/20/2021] [Indexed: 02/05/2023] Open
Abstract
Nuclear medicine has evolved over the last half-century from a functional imaging modality using a handful of radiopharmaceuticals, many of unknown structure and mechanism of action, into a modern speciality that can properly be described as molecular imaging, with a very large number of specific radioactive probes of known structure that image specific molecular processes. The advances of cancer treatment in recent decades towards targeted and immune therapies, combined with recognition of heterogeneity of cancer cell phenotype among patients, within patients and even within tumours, has created a growing need for personalised molecular imaging to support treatment decision. This article describes the evolution of the present vast range of radioactive probes – radiopharmaceuticals – leveraging a wide variety of chemical disciplines, over the last half century. These radiochemical innovations have been inspired by the need to support personalised medicine and also by the parallel development in development of new radionuclide imaging technologies – from gamma scintigraphy, through single photon emission tomography (SPECT), through the rise of clinical positron emission tomography (PET) and PET-CT, and perhaps in the future, by the advent of total body PET. Thus, in the interdisciplinary world of nuclear medicine and molecular imaging, as quickly as radiochemistry solutions are developed to meet new needs in cancer imaging, new challenges emerge as developments in one contributing technology drive innovations in the others.
Collapse
|
16
|
11C Dosimetry Scans Should Be Abandoned. J Nucl Med 2020; 62:158-159. [PMID: 33310737 DOI: 10.2967/jnumed.120.257402] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 09/22/2020] [Indexed: 12/12/2022] Open
|
17
|
Incremental diagnostic value of [ 18F]tetrafluoroborate PET-CT compared to [ 131I]iodine scintigraphy in recurrent differentiated thyroid cancer. Eur J Nucl Med Mol Imaging 2020; 47:2639-2646. [PMID: 32248325 PMCID: PMC7515952 DOI: 10.1007/s00259-020-04727-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Accepted: 02/14/2020] [Indexed: 12/13/2022]
Abstract
INTRODUCTION Efficient therapy of recurrent differentiated thyroid cancer (DTC) is dependent on precise molecular imaging techniques targeting the human sodium iodide symporter (hNIS), which is a marker both of thyroid and DTC cells. Various iodine isotopes have been utilized for detecting DTC; however, these come with unfavorable radiation exposure and image quality ([131I]iodine) or limited availability ([124I]iodine). In contrast, [18F]tetrafluoroborate (TFB) is a novel radiolabeled PET substrate of hNIS, results in PET images with high-quality and low radiation doses, and should therefore be suited for imaging of DTC. The aim of the present study was to compare the diagnostic performance of [18F]TFB-PET to the clinical reference standard [131I]iodine scintigraphy in patients with recurrent DTC. METHODS Twenty-five patients with recurrent DTC were included in this retrospective analysis. All patients underwent [18F]TFB-PET combined with either CT or MRI due to newly discovered elevated TG levels, antiTG levels, sonographically suspicious cervical lymph nodes, or combinations of these findings. Correlative [131I]iodine whole-body scintigraphy (dxWBS) including SPECT-CT was present for all patients; correlative [18F]FDG-PET-CT was present for 21 patients. Histological verification of [18F]TFB positive findings was available in 4 patients. RESULTS [18F]TFB-PET detected local recurrence or metastases of DTC in significantly more patients than conventional [131I]iodine dxWBS and SPECT-CT (13/25 = 52% vs. 3/25 = 12%, p = 0.002). The diagnosis of 6 patients with cervical lymph node metastases that showed mildly increased FDG metabolism but negative [131I]iodine scintigraphy was changed: [18F]TFB-PET revealed hNIS expression in the metastases, which were therefore reclassified as only partly de-differentiated (histological confirmation present in two patients). Highest sensitivity for detecting recurrent DTC had the combination of [18F]TFB-PET-CT/MRI with [18F]FDG-PET-CT (64%). CONCLUSION In the present cohort, [18F]TFB-PET shows higher sensitivity and accuracy than [131I]iodine WBS and SPECT-CT in detecting recurrent DTC. The combination of [18F]TFB-PET with [18F]FDG-PET-CT seems a reasonable strategy to characterize DTC tumor manifestations with respect to their differentiation and thereby also individually plan and monitor treatment. Future prospective studies evaluating the potential of [18F]TFB-PET in recurrent DTC are warranted.
Collapse
|
18
|
CRISPR/Cas9-mediated introduction of the sodium/iodide symporter gene enables noninvasive in vivo tracking of induced pluripotent stem cell-derived cardiomyocytes. Stem Cells Transl Med 2020; 9:1203-1217. [PMID: 32700830 PMCID: PMC7519772 DOI: 10.1002/sctm.20-0019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 05/10/2020] [Accepted: 05/24/2020] [Indexed: 12/31/2022] Open
Abstract
Techniques that enable longitudinal tracking of cell fate after myocardial delivery are imperative for optimizing the efficacy of cell‐based cardiac therapies. However, these approaches have been underutilized in preclinical models and clinical trials, and there is considerable demand for site‐specific strategies achieving long‐term expression of reporter genes compatible with safe noninvasive imaging. In this study, the rhesus sodium/iodide symporter (NIS) gene was incorporated into rhesus macaque induced pluripotent stem cells (RhiPSCs) via CRISPR/Cas9. Cardiomyocytes derived from NIS‐RhiPSCs (NIS‐RhiPSC‐CMs) exhibited overall similar morphological and electrophysiological characteristics compared to parental control RhiPSC‐CMs at baseline and with exposure to physiological levels of sodium iodide. Mice were injected intramyocardially with 2 million NIS‐RhiPSC‐CMs immediately following myocardial infarction, and serial positron emission tomography/computed tomography was performed with 18F‐tetrafluoroborate to monitor transplanted cells in vivo. NIS‐RhiPSC‐CMs could be detected until study conclusion at 8 to 10 weeks postinjection. This NIS‐based molecular imaging platform, with optimal safety and sensitivity characteristics, is primed for translation into large‐animal preclinical models and clinical trials.
Collapse
|
19
|
Chemistry Considerations for the Clinical Translation of Oncology PET Radiopharmaceuticals. Mol Pharm 2020; 17:2245-2259. [DOI: 10.1021/acs.molpharmaceut.0c00328] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
20
|
|
21
|
[ 18F]Tetrafluoroborate ([ 18F]TFB) and its analogs for PET imaging of the sodium/iodide symporter. Theranostics 2018; 8:3918-3931. [PMID: 30083270 PMCID: PMC6071519 DOI: 10.7150/thno.24997] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Accepted: 03/16/2018] [Indexed: 12/27/2022] Open
Abstract
Sodium/iodide symporter (NIS)-mediated iodide uptake in thyroid follicular cells is the basis of clinical utilization of radioiodines. The cloning of the NIS gene enabled applications of NIS as a reporter gene in both preclinical and translational research. Non-invasive NIS imaging with radioactive iodides and iodide analogs has gained much interest in recent years for evaluation of thyroid cancer and NIS reporter expression. Although radioiodines and [99mTc]pertechnetate ([99mTc]TcO4-) have been utilized in positron emission tomography (PET) and single photon emission computed tomography (SPECT), they may suffer from limitations of availability, undesirable decay properties or imaging sensitivity (SPECT versus PET). Recently, [18F]tetrafluoroborate ([18F]TFB or [18F]BF4-) and other fluorine-18 labeled iodide analogs have emerged as a promising iodide analog for PET imaging. These fluorine-18 labeled probes have practical radiosyntheses and biochemical properties that allow them to closely mimic iodide transport by NIS in thyroid, as well as in other NIS-expressing tissues. Unlike radioiodides, they do not undergo organification in thyroid cells, which results in an advantage of relatively lower uptake in normal thyroid tissue. Initial clinical trials of [18F]TFB have been completed in healthy human subjects and thyroid cancer patients. The excellent imaging properties of [18F]TFB for evaluation of NIS-expressing tissues indicate its bright future in PET NIS imaging. This review focuses on the recent evolution of [18F]TFB and other iodide analogs and their potential value in research and clinical practice.
Collapse
|
22
|
Synthesis and evaluation of 18F-hexafluorophosphate as a novel PET probe for imaging of sodium/iodide symporter in a murine C6-glioma tumor model. Bioorg Med Chem 2017; 26:225-231. [PMID: 29198608 DOI: 10.1016/j.bmc.2017.11.034] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 11/18/2017] [Accepted: 11/21/2017] [Indexed: 12/27/2022]
Abstract
Noninvasive imaging of iodide uptake via the sodium/iodide symporter (NIS) has received great interest for evaluation of thyroid cancer and reporter imaging of NIS-expressing viral therapies. In this study, we investigate 18F-labeled hexafluorophosphate (HFP or PF6-) as a high-affinity iodide analog for NIS imaging. 18F-HFP was synthesized by radiofluorination of phosphorus pentafluoride·N-methylpyrrolidine complex and evaluated in human NIS (hNIS)-expressing C6 glioma cells and a C6 glioma xenograft mouse model. 18F-HFP was obtained in radiochemical yield of 10 ± 5%, radiochemical purity of >96% and specific radioactivity of 604 ± 18 MBq/µmol. Specific uptake of 18F-HFP and high affinity of 19F-HFP were observed in hNIS+ C6-glioma cells. PET imaging showed robust uptake of 18F-HFP in NIS-expressing tissues (thyroid, stomach, and hNIS+ C6 glioma xenografts), and the uptake of 18F-HFP was blocked by NaClO4 pretreatment. Specific accumulation in hNIS-expressing xenograft (hNIS+) was observed relative to isogenic control tumor (hNIS-). Clearance of 18F-HFP was predominantly through renal excretion. The biodistribution showed consistent results with PET imaging. Minimal bone uptake was observed over 2 h period post-injection, indicating excellent in vivo stability of 18F-HFP. Although improvement in specific radioactivity is desirable, the results indicate that 18F-HFP is a promising candidate radiotracer for further evaluation for NIS imaging.
Collapse
|