1
|
Hoffmann E, Masthoff M, Kunz WG, Seidensticker M, Bobe S, Gerwing M, Berdel WE, Schliemann C, Faber C, Wildgruber M. Multiparametric MRI for characterization of the tumour microenvironment. Nat Rev Clin Oncol 2024; 21:428-448. [PMID: 38641651 DOI: 10.1038/s41571-024-00891-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/04/2024] [Indexed: 04/21/2024]
Abstract
Our understanding of tumour biology has evolved over the past decades and cancer is now viewed as a complex ecosystem with interactions between various cellular and non-cellular components within the tumour microenvironment (TME) at multiple scales. However, morphological imaging remains the mainstay of tumour staging and assessment of response to therapy, and the characterization of the TME with non-invasive imaging has not yet entered routine clinical practice. By combining multiple MRI sequences, each providing different but complementary information about the TME, multiparametric MRI (mpMRI) enables non-invasive assessment of molecular and cellular features within the TME, including their spatial and temporal heterogeneity. With an increasing number of advanced MRI techniques bridging the gap between preclinical and clinical applications, mpMRI could ultimately guide the selection of treatment approaches, precisely tailored to each individual patient, tumour and therapeutic modality. In this Review, we describe the evolving role of mpMRI in the non-invasive characterization of the TME, outline its applications for cancer detection, staging and assessment of response to therapy, and discuss considerations and challenges for its use in future medical applications, including personalized integrated diagnostics.
Collapse
Affiliation(s)
- Emily Hoffmann
- Clinic of Radiology, University of Münster, Münster, Germany
| | - Max Masthoff
- Clinic of Radiology, University of Münster, Münster, Germany
| | - Wolfgang G Kunz
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Max Seidensticker
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Stefanie Bobe
- Gerhard Domagk Institute of Pathology, University Hospital Münster, Münster, Germany
| | - Mirjam Gerwing
- Clinic of Radiology, University of Münster, Münster, Germany
| | | | | | - Cornelius Faber
- Clinic of Radiology, University of Münster, Münster, Germany
| | - Moritz Wildgruber
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany.
| |
Collapse
|
2
|
Cox CPW, Brabander T, Vegt E, de Lussanet de la Sablonière QG, Graven LH, Verburg FA, Segbers M. Reduction of [ 68Ga]Ga-DOTA-TATE injected activity for digital PET/MR in comparison with analogue PET/CT. EJNMMI Phys 2024; 11:27. [PMID: 38488989 PMCID: PMC11266332 DOI: 10.1186/s40658-024-00629-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 03/06/2024] [Indexed: 03/17/2024] Open
Abstract
BACKGROUND New digital detectors and block-sequential regularized expectation maximization (BSREM) reconstruction algorithm improve positron emission tomography (PET)/magnetic resonance (MR) image quality. The impact on image quality may differ from analogue PET/computed tomography (CT) protocol. The aim of this study is to determine the potential reduction of injected [68Ga]Ga-DOTA-TATE activity for digital PET/MR with BSREM reconstruction while maintaining at least equal image quality compared to the current analogue PET/CT protocol. METHODS NEMA IQ phantom data and 25 patients scheduled for a diagnostic PET/MR were included. According to our current protocol, 1.5 MBq [68Ga]Ga-DOTA-TATE per kilogram (kg) was injected. After 60 min, scans were acquired with 3 (≤ 70 kg) or 4 (> 70 kg) minutes per bedposition. PET/MR scans were reconstructed using BSREM and factors β 150, 300, 450 and 600. List mode data with reduced counts were reconstructed to simulate scans with 17%, 33%, 50% and 67% activity reduction. Image quality was measured quantitatively for PET/CT and PET/MR phantom and patient data. Experienced nuclear medicine physicians performed visual image quality scoring and lesion counting in the PET/MR patient data. RESULTS Phantom analysis resulted in a possible injected activity reduction of 50% with factor β = 600. Quantitative analysis of patient images revealed a possible injected activity reduction of 67% with factor β = 600. Both with equal or improved image quality as compared to PET/CT. However, based on visual scoring a maximum activity reduction of 33% with factor β = 450 was acceptable, which was further limited by lesion detectability analysis to an injected activity reduction of 17% with factor β = 450. CONCLUSION A digital [68Ga]Ga-DOTA-TATE PET/MR together with BSREM using factor β = 450 result in 17% injected activity reduction with quantitative values at least similar to analogue PET/CT, without compromising on PET/MR visual image quality and lesion detectability.
Collapse
Affiliation(s)
- Christina P W Cox
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands.
| | - Tessa Brabander
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Erik Vegt
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Quido G de Lussanet de la Sablonière
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Laura H Graven
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Frederik A Verburg
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Postbus 2040, 3000 CA, Rotterdam, The Netherlands
| |
Collapse
|
3
|
Kalaitzidis P, Gustafsson J, Hindorf C, Ljungberg M. Monte Carlo investigation of PET [ 68Ga]Ga-DOTA-TOC activity-administration protocols for consistent image quality. Heliyon 2023; 9:e19504. [PMID: 37681181 PMCID: PMC10480678 DOI: 10.1016/j.heliyon.2023.e19504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 08/24/2023] [Accepted: 08/24/2023] [Indexed: 09/09/2023] Open
Abstract
One example of a PET exam that suffers from noise problems is [68Ga]Ga-DOTA-TOC, where patients are generally administered between 100 and 200 MBq [68Ga]Ga-DOTA-TOC, irrespective of size. However, a fixed activity can result in low signal-to-noise ratios (SNRs) in larger patients. This study aimed to evaluate the impact on image quality with respect to injected activity and patient habitus through Monte Carlo (MC) simulation. Eight anthropomorphic computer phantoms with body mass indices (BMIs) between 19 kg/m2 and 38 kg/m2 and tumours distributed in the liver were simulated using the MC software Gate v8.2 with an activity distribution defined according to [68Ga]Ga-DOTA-TOC standardised uptake values. Three activity-administration protocols were simulated: (i) with a fixed activity of 100 MBq, (ii) with the activity scaled by 2 MBq/kg, and (iii) with the activity scaled by a body size-dependent power-function based on the SNR obtained with (ii). BMI, weight, body surface area, and abdominal circumference were evaluated body size parameters. Images were reconstructed with the CASToR software and evaluated for background SNR and lesion contrast-to-noise ratio (CNR). Large SNR variabilities were obtained with protocols (i) and (ii), while (iii) generated good consistency. Several tumours failed to reach a CNR of 5 for large phantoms with protocol (i), but the CNR was generally improved by (ii) and (iii). An activity scaled by patient habitus generate better image quality consistency, which increases the likelihood that patients receive a similar standard of care.
Collapse
Affiliation(s)
| | | | - Cecilia Hindorf
- Medical Radiation Physics, Lund, Lund University, Lund, Sweden
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Stockholm, Sweden
| | | |
Collapse
|
4
|
Liu L, Chen X, Wan L, Zhang N, Hu R, Li W, Liu S, Zhu Y, Pang H, Liang D, Chen Y, Hu Z. Feasibility of a deep learning algorithm to achieve the low-dose 68Ga-FAPI/the fast-scan PET images: a multicenter study. Br J Radiol 2023; 96:20230038. [PMID: 37393527 PMCID: PMC10461288 DOI: 10.1259/bjr.20230038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/26/2023] [Accepted: 06/04/2023] [Indexed: 07/03/2023] Open
Abstract
OBJECTIVES Our work aims to study the feasibility of a deep learning algorithm to reduce the 68Ga-FAPI radiotracer injected activity and/or shorten the scanning time and to investigate its effects on image quality and lesion detection ability. METHODS The data of 130 patients who underwent 68Ga-FAPI positron emission tomography (PET)/CT in two centers were studied. Predicted full-dose images (DL-22%, DL-28% and DL-33%) were obtained from three groups of low-dose images using a deep learning method and compared with the standard-dose images (raw data). Injection activity for full-dose images was 2.16 ± 0.61 MBq/kg. The quality of the predicted full-dose PET images was subjectively evaluated by two nuclear physicians using a 5-point Likert scale, and objectively evaluated by the peak signal-to-noise ratio, structural similarity index and root mean square error. The maximum standardized uptake value and the mean standardized uptake value (SUVmean) were used to quantitatively analyze the four volumes of interest (the brain, liver, left lung and right lung) and all lesions, and the lesion detection rate was calculated. RESULTS Data showed that the DL-33% images of the two test data sets met the clinical diagnosis requirements, and the overall lesion detection rate of the two centers reached 95.9%. CONCLUSION Through deep learning, we demonstrated that reducing the 68Ga-FAPI injected activity and/or shortening the scanning time in PET/CT imaging was feasible. In addition, 68Ga-FAPI dose as low as 33% of the standard dose maintained acceptable image quality. ADVANCES IN KNOWLEDGE This is the first study of low-dose 68Ga-FAPI PET images from two centers using a deep learning algorithm.
Collapse
Affiliation(s)
| | | | - Liwen Wan
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | | | - Ruibao Hu
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Wenbo Li
- Department of Nuclear Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Shengping Liu
- Chongqing University of Technology, Chongqing, China
| | | | - Hua Pang
- Department of Nuclear Medicine, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Dong Liang
- Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | | | | |
Collapse
|
5
|
Al-Fatlawi M, Pak F, Farzanefar S, Salehi Y, Monsef A, Sheikhzadeh P. Optimization of the Acquisition Time and Injected Dose of 18 F-Fluorodeoxyglucose Based on Patient Specifications for High-Sensitive Positron Emission Tomography/Computed Tomography Scanner. World J Nucl Med 2023; 22:196-202. [PMID: 37854082 PMCID: PMC10581753 DOI: 10.1055/s-0043-1771284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023] Open
Abstract
Background This study was aimed to optimize the fluorodeoxyglucose (FDG)-administered dose and scan time based on patient specifications using a highly sensitive five-ring bismuth germanium oxide (BGO)-based positron emission tomography/computed tomography (PET/CT) scanner (Discovery IQ). Methods We retrospectively analyzed 101 whole-body 18 F-FDG PET/CT images. Patient data were reconstructed using ordered subset expectation maximization with resolution recovery algorithms (OSEM + SharpIR). Signal-to-noise ratio (SNR) was calculated for each patient, standardized to SNR norm , and plotted against three body index parameters (weight, body mass index, and lean body mass). Two professional physicians blindly examined image quality at different patient time per bed positions to determine the minimum acceptable quality. To select images of acceptable quality, the noise index parameter was also measured. A new dose-time product (DTP) was established for each patient, and a predicted injected dose was assumed. Results We found an almost linear association between patient weight and normalized SNR, and patient weight had the highest R 2 in the fitting. The redesigned DTP can reduce results by approximately 74 and 38% compared with ordinary DTP for 80- and 160-s scan durations. The new dose regimen formula was found to be DTP = c/t × m 1.24 , where m is the patient weight, t is the scan time per bed position, and c is 1.8 and 4.3 for acceptable and higher confidence states, respectively, in Discovery IQ PET/CT. Conclusion Patient weight is the best clinical parameter for the implementation of 18 F-FDG PET/CT image quality assessment. A new dose-time regimen based on body weight was proposed for use in highly sensitive five-ring BGO PET-CT scanners to significantly reduce the injection dose and scan times while maintaining sufficient image quality for diagnosis.
Collapse
Affiliation(s)
- Murtadha Al-Fatlawi
- Radiological Techniques Department, AL-Mustaqbal University College, Babel, Iraq
| | - Farideh Pak
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, United States
| | - Saeed Farzanefar
- Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| | - Yalda Salehi
- Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| | - Abbas Monsef
- Department of Radiology, Center for Magnetic Resonance Research, University of Minnesota Medical School, Minneapolis, United States
- Department of Radiation Oncology, University of Minnesota Medical School, Minneapolis, United States
| | - Peyman Sheikhzadeh
- Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
A personal acquisition time regimen of 68Ga-DOTATATE total-body PET/CT in patients with neuroendocrine tumor (NET): a feasibility study. Cancer Imaging 2022; 22:78. [PMID: 36578034 PMCID: PMC9798642 DOI: 10.1186/s40644-022-00517-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 12/19/2022] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND The injection activity of tracer, acquisition time, patient-specific photon attenuation, and large body mass, can influence on image quality. Fixed acquisition time and body mass related injection activity in clinical practice results in a large difference in image quality. Thus, this study proposes a patient-specific acquisition time regimen of 68 Ga-DOTATATE total-body positron emission tomography-computed tomography (PET/CT) to counteract the influence of body mass (BM, kg) on image quality, and acquire an acceptable and constant image of patients with neuroendocrine tumors (NETs). METHODS The development cohort consisting of 19 consecutive patients with full activity (88.7-204.9 MBq, 2.0 ± 0.1 MBq/kg) was to establish the acquisition time regimen. The liver SNR (signal-to-noise ratio, SNRL) was normalized (SNRnorm) by the product of injected activity (MBq) and acquisition time (min). Fitting of SNRnorm against body mass (BM, kg) in linear correlation was performed. Subjective assessment of image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL, and an optimized acquisition regimen based on BM was proposed, and validated its feasibility through the validation cohort of 57 consecutive NET patients with half activity (66.9 ± 11.3 MBq, 1.0 ± 0.1 MBq/kg) and a fixed acquisition time regimen. RESULTS The linear correlation (R2 = 0.63) between SNRnorm and BM (kg) was SNRnorm = -0.01*BM + 1.50. The threshold SNRL of acceptable image quality was 11.2. The patient-specific variable acquisition time regimen was determined as: t (min) = 125.4/(injective activity)*(-0.01*BM + 1.50)2. Based on that proposed regimen, the average acquisition time for acceptable image quality in the validation cohort was 2.99 ± 0.91 min, ranging from 2.18 to 6.35 min, which was reduced by 36.50% ~ 78.20% compared with the fixed acquisition time of 10 min. Subjective evaluation showed that acceptable image quality could be obtained at 3.00 min in the validation group, with an average subjective score of 3.44 ± 0.53 (kappa = 0.97, 95% CI: 0.96 ~ 0.98). Bland-Altman analysis revealed good agreement between the proposed regimen and the fixed acquisition time cohort. CONCLUSION A patient-specific acquisition time regimen was proposed in NET patients in development cohort and validated its feasibility in patients with NETs in validation cohort by 68 Ga-DOTATATE total-body PET/CT imaging. Based on the proposed regimen, the homogenous image quality with optimal acquisition time was available independent of body mass.
Collapse
|
7
|
Riveira-Martin M, Struelens L, Schoonjans W, Sánchez-Díaz I, Muñoz Iglesias J, Ferreira Dávila Ó, Salvador Gómez FJ, Salgado Fernández M, López Medina A. Occupational radiation exposure assessment during the management of [68Ga]Ga-DOTA-TOC. EJNMMI Phys 2022; 9:75. [PMID: 36309605 PMCID: PMC9617990 DOI: 10.1186/s40658-022-00505-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 10/20/2022] [Indexed: 11/25/2022] Open
Abstract
Background Since it was first approved in Europe in 2016, the gallium-68 (68Ga) radiopharmaceutical [68Ga]Ga-DOTA-TOC has been widely used for imaging of somatostatin receptor (SSTR) positive tumours using positron emission tomography–computed tomography (PET/CT). Significant patient benefits have been reported, so its use is rapidly increasing. However, few studies have been published regarding occupational doses to nuclear medicine personnel handling this radiopharmaceutical, despite its manual usage at low distances from the skin and the beta-emission decay scheme, which may result in an increased absorbed dose to their hands. In this context, this study aims to analyse the occupational exposure during the administration of [68Ga]Ga-DOTA-TOC for PET/CT imaging. For this purpose, extremity, eye lens and whole-body dosimetry in terms of Hp(0.07), Hp(3) and Hp(10), respectively, was conducted on six workers with both thermoluminescent dosimeters, and personal electronic dosimeters.
Results The non-dominant hand is more exposed to radiation than the dominant hand, with the thumb and the index fingertip being the most exposed sites on this hand. Qualitative analysis showed that when no shielding is used during injection, doses increase significantly more in the dominant than in the non-dominant hand, so the use of shielding is strongly recommended. While wrist dosimeters may significantly underestimate doses to the hands, placing a ring dosimeter at the base of the ring or middle finger of the non-dominant hand may give a valuable estimation of maximum doses to the hands if at least a correction factor of 5 is applied. Personal equivalent doses for the eyes did not result in measurable values (i.e., above the lowest detection limit) for almost all workers. The extrapolated annual dose estimations showed that there is compliance with the annual dose limits during management of [68Ga]Ga-DOTA-TOC for diagnostics with PET in the hospital included in this study. Conclusions Imaging with [68Ga]Ga-DOTA-TOC is a safe process for the workers performing the administration of the radiopharmaceutical, including intravenous injection to the patient and the pre- and post-activity control, as it is highly unlikely that annual dose limits will be exceeded if good working practices and shielding are used.
Supplementary Information The online version contains supplementary material available at 10.1186/s40658-022-00505-8.
Collapse
|
8
|
Zanoni L, Calabrò D, Fortunati E, Argalia G, Malizia C, Allegri V, Civollani S, Fanti S, Ambrosini V. Two birds with one stone: can [68Ga]Ga-DOTANOC PET/CT image quality be improved through BMI-adjusted injected activity without increasing acquisition times? Br J Radiol 2022; 95:20211152. [PMID: 35230151 PMCID: PMC10996427 DOI: 10.1259/bjr.20211152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 01/22/2022] [Accepted: 02/16/2022] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To assess how patients' dependent parameters may affect [68Ga]Ga-DOTANOC image quality and to propose a theoretical body mass index (BMI)-adjusted injected activity (IA) scheme, to improve imaging of high weight patients. METHODS Among patients prospectively enrolled (June-2019 and May-2020) in an Institutional Ethical Committee-approved electronic archive, we included those affected by primary gastro-entero-pancreatic (GEP) or lung neuroendocrine tumour and referred by our Institutional clinicians (excluding even minimal radiopharmaceutical extravasation, movement artefacts, renal insufficiency). All PET/CT images were acquired following EANM guidelines and rated for visual quality (1 = non-diagnostic, 2 = poor, 3 = moderate, 4 = good). Collected data included patient's body mass, height, BMI, age, IA (injected activity), IA/Kg (IAkg), IA/BMI (IABMI), liver SUVmean, liver SUVmax standard deviation, liver-signal-to-noise (LSNR), normalised_LSNR (LSNR_norm) and contrast-to-noise ratio (CNR) for positive scans and were compared to image rating (poor vs moderate/good). RESULTS Overall, 77 patients were included. Rating concordance was high (agreement = 81.8%, Fleiss k score = 0.806). All patients' dependent parameters resulted significantly different between poor-rated and moderate/good-rated scans (IA: p = 0.006, IAkg: p =< 0.001, body weight: p =< 0.001, BMI: p =< 0.001, IABMI: p =< 0.001). Factors significantly associated with moderate/good rating were BMI (p =< 0.001), body weight (p =< 0.001), IABMI (p =< 0.001), IAkg (p = 0.001), IA (p = 0.003), LSNR_norm (p = 0.01). The BMI-based model presented the best predictive efficiency (81.82%). IABMI performance to differentiate moderate/good from poor rating resulted statistically significant (IA-AUC = 0.78; 95% CI: 0.68-0.89; cut-off value of 4.17 MBq*m2/kg, sensitivity = 81.1%, specificity = 66.7%). If BMI-adjusted IA (=4.17*BMI) would have been applied in this population, the median IA would have slightly inferior (-4.8%), despite a different IA in each patient. ADVANCES IN KNOWLEDGE BMI resulted the best predictor of image quality. The proposed theoretical BMI-adjusted IA scheme (4.17*BMI) should yield images of better quality (especially in high-BMI patients) maintaining practical scanning times (3 min/bed).
Collapse
Affiliation(s)
- Lucia Zanoni
- Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria
di Bologna, Bologna,
Italy
| | - Diletta Calabrò
- Department of Experimental Diagnostic and Specialized Medicine
(DIMES), Alma Mater Studiorum University of Bologna,
Bologna, Italy
| | - Emilia Fortunati
- Department of Experimental Diagnostic and Specialized Medicine
(DIMES), Alma Mater Studiorum University of Bologna,
Bologna, Italy
| | - Giulia Argalia
- Department of Experimental Diagnostic and Specialized Medicine
(DIMES), Alma Mater Studiorum University of Bologna,
Bologna, Italy
| | - Claudio Malizia
- Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria
di Bologna, Bologna,
Italy
| | - Vincenzo Allegri
- Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria
di Bologna, Bologna,
Italy
| | - Simona Civollani
- Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria
di Bologna, Bologna,
Italy
| | - Stefano Fanti
- Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria
di Bologna, Bologna,
Italy
- Department of Experimental Diagnostic and Specialized Medicine
(DIMES), Alma Mater Studiorum University of Bologna,
Bologna, Italy
| | - Valentina Ambrosini
- Nuclear Medicine Unit, IRCCS Azienda Ospedaliero-Universitaria
di Bologna, Bologna,
Italy
- Department of Experimental Diagnostic and Specialized Medicine
(DIMES), Alma Mater Studiorum University of Bologna,
Bologna, Italy
| |
Collapse
|
9
|
Cox CPW, van Assema DME, Verburg FA, Brabander T, Konijnenberg M, Segbers M. A dedicated paediatric [ 18F]FDG PET/CT dosage regimen. EJNMMI Res 2021; 11:65. [PMID: 34279735 PMCID: PMC8289942 DOI: 10.1186/s13550-021-00812-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 07/09/2021] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND The role of 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) in children is still expanding. Dedicated paediatric dosage regimens are needed to keep the radiation dose as low as reasonably achievable and reduce the risk of radiation-induced carcinogenesis. The aim of this study is to investigate the relation between patient-dependent parameters and [18F]FDG PET image quality in order to propose a dedicated paediatric dose regimen. METHODS In this retrospective analysis, 102 children and 85 adults were included that underwent a diagnostic [18F]FDG PET/CT scan. The image quality of the PET scans was measured by the signal-to-noise ratio (SNR) in the liver. The SNR liver was normalized (SNRnorm) for administered activity and acquisition time to apply curve fitting with body weight, body length, body mass index, body weight/body length and body surface area. Curve fitting was performed with two power fits, a nonlinear two-parameter model α p-d and a linear single-parameter model α p-0.5. The fit parameters of the preferred model were combined with a user preferred SNR to obtain at least moderate or good image quality for the dosage regimen proposal. RESULTS Body weight demonstrated the highest coefficient of determination for the nonlinear (R2 = 0.81) and linear (R2 = 0.80) models. The nonlinear model was preferred by the Akaike's corrected information criterion. We decided to use a SNR of 6.5, based on the expert opinion of three nuclear medicine physicians. Comparison with the quadratic adult protocol confirmed the need for different dosage regimens for both patient groups. In this study, the amount of administered activity can be considerably reduced in comparison with the current paediatric guidelines. CONCLUSION Body weight has the strongest relation with [18F]FDG PET image quality in children. The proposed nonlinear dosage regimen based on body mass will provide a constant and clinical sufficient image quality with a significant reduction of the effective dose compared to the current guidelines. A dedicated paediatric dosage regimen is necessary, as a universal dosing regimen for paediatric and adult is not feasible.
Collapse
Affiliation(s)
- Christina P W Cox
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Postbus, 2040 3000 CA, Rotterdam, The Netherlands.
| | - Daniëlle M E van Assema
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Postbus, 2040 3000 CA, Rotterdam, The Netherlands
| | - Frederik A Verburg
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Postbus, 2040 3000 CA, Rotterdam, The Netherlands
| | - Tessa Brabander
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Postbus, 2040 3000 CA, Rotterdam, The Netherlands
| | - Mark Konijnenberg
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Postbus, 2040 3000 CA, Rotterdam, The Netherlands
| | - Marcel Segbers
- Department of Radiology & Nuclear Medicine, Erasmus Medical Center, Postbus, 2040 3000 CA, Rotterdam, The Netherlands
| |
Collapse
|
10
|
Virgolini I, Bahri S, Kjaer A, Gronbaek H, Iversen P, Carlsen EA, Loft M, Knigge U, Maffey-Steffan J, Powell C, Miller CG, Rohban T, McEwan S, Czernin J. A randomised, factorial phase II study to determine the optimal dosing regimen for 68Ga-satoreotide trizoxetan as an imaging agent in patients with gastroenteropancreatic neuroendocrine tumours. J Nucl Med 2021; 63:376-383. [PMID: 34215673 PMCID: PMC8978200 DOI: 10.2967/jnumed.121.261936] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 06/07/2021] [Indexed: 11/16/2022] Open
Abstract
68Ga-satoreotide trizoxetan is a novel somatostatin receptor antagonist associated with high sensitivity and reproducibility in neuroendocrine tumour (NET) detection and localisation. However, the optimal peptide mass and radioactivity ranges for 68Ga-satoreotide trizoxetan have not yet been established. We therefore aimed to determine its optimal dosing regimen in patients with metastatic gastroenteropancreatic NETs in a prospective, randomised, 2×3 factorial, multicentre, phase II study. Methods: Patients received 68Ga-satoreotide trizoxetan at a peptide mass of 5-20 µg on day 1 of the study and of 30-45 µg on day 16-22, at one of three gallium-68 radioactivity ranges (40-80, 100-140, or 160-200 MBq). Whole-body PET/CT imaging was performed 50-70 minutes after each injection. The primary endpoint was the detection rate of NET lesions imaged by 68Ga-satoreotide trizoxetan relative to contrast-enhanced CT (CECT) (for each of the six peptide mass/radioactivity range combinations). Results: Twenty-four patients were evaluated in the per-protocol analysis. The median number of lesions detected by 68Ga-satoreotide trizoxetan PET/CT or PET only was at least twice as high as the number of lesions detected by CECT across the six studied peptide mass dose/radioactivity range combinations. There were no differences between the two peptide mass ranges and between the three radioactivity ranges in the number of identified lesions. However, a trend towards a lower relative lesion count was noted in the liver for the 40-80 MBq range. No relationship was observed between the radioactivity range per patient's body weight (MBq/kg) and the number of lesions detected by 68Ga-satoreotide trizoxetan. Median diagnostic sensitivity of 68Ga-satoreotide trizoxetan PET/CT, based on the number of lesions per patient, ranged from 85% to 87% across the different peptide mass and radioactivity ranges. Almost all reported adverse events were mild and self-limiting. Conclusion: A radioactivity of 100-200 MBq with a peptide mass up to 50 μg were confirmed as the optimal dosing regimen for 68Ga-satoreotide trizoxetan to be used in future phase III studies.
Collapse
Affiliation(s)
- Irene Virgolini
- Department of Nuclear Medicine, University of Innsbruck, Austria
| | - Shadfar Bahri
- Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, UCLA, United States
| | - Andreas Kjaer
- Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Department of Biomedical Sciences, Rigshospitalet, University of Copenhagen
| | - Henning Gronbaek
- Department of Hepatology & Gastroenterology, Aarhus University Hospital
| | - Peter Iversen
- Department of Nuclear Medicine and PET Center, Aarhus University Hospital, Denmark
| | - Esben Andreas Carlsen
- Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Department of Biomedical Sciences, Rigshospitalet, University of Copenhagen
| | - Mathias Loft
- Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Department of Biomedical Sciences, Rigshospitalet, University of Copenhagen
| | - Ulrich Knigge
- Department of Endocrinology PE and Department of Surgery C, Rigshospitalet, University of Copenhagen, Denmark
| | | | | | | | | | | | - Johannes Czernin
- Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, UCLA, United States
| |
Collapse
|
11
|
Can the BMI-based dose regimen be used to reduce injection activity and to obtain a constant image quality in oncological patients by 18F-FDG total-body PET/CT imaging? Eur J Nucl Med Mol Imaging 2021; 49:269-278. [PMID: 34185138 DOI: 10.1007/s00259-021-05462-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 06/10/2021] [Indexed: 12/16/2022]
Abstract
PURPOSE PET image quality is influenced by the patient size according to the current guideline. The study aimed to propose an optimized dose regimen to yield a constant image quality independent of patient habitus to meet the clinical needs. METHODS A first patient cohort of 78 consecutive oncological patients (59.7 ± 13.7 years) who underwent a total-body PET/CT scan were retrospectively enrolled to develop the regimen. The patients were randomly distributed in four body mass index (BMI) groups according to the World Health Organization (WHO) criteria. The liver SNR (signal-to-noise ratio, SNRL) was obtained by manually drawing regions of interest (ROIs) and normalized (SNRnorm) by the product of injected activity and acquisition time. Fits of SNRnorm against different patient-dependent parameters were performed to determine the best correlating parameter and fit method. A qualitative assessment on image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL. Thus, an optimized regimen was proposed and validated by a second patient cohort consisted of prospectively enrolled 38 oncological patients. RESULTS The linear fit showed SNRnorm had the strongest correlation (R2 = 0.69) with the BMI than other patient-dependent parameters and fit method. The qualitative assessment indicated a SNRL value of 14.0 as an acceptable threshold to achieve sufficient image quality. The optimized dose regimen was determined as a quadratic relation with BMI: injected activity (MBq) = 39.2 (MBq)/(- 0.03*BMI + 1.49)2. In the validation study, the SNRL no longer decreased with the increase of BMI. There was no significant difference of the image quality regarding the value of SNRL between different BMI groups (p > 0.05). In addition, the injected activity was reduced by 75.6 ± 2.9%, 72.1 ± 4.0%, 67.1 ± 4.4%, and 64.8 ± 3.5% compared with the first cohort for the four BMI groups, respectively. CONCLUSION The study proposed a quadratic relation between the 18F-FDG injected activity and the patient's BMI for total-body 18F-FDG PET imaging. In this regimen, the image quality can maintain in a constant level independent of patient habitus and meet the clinical requirement with a reduced injected activity.
Collapse
|