Akhtar Z, Kontogiannis C, Georgiopoulos G, Starck CT, Leung LWM, Lee SY, Lee BK, Seshasai SRK, Sohal M, Gallagher MM. Comparison of non-laser and laser transvenous lead extraction: a systematic review and meta-analysis. Europace 2023; 25:euad316. [PMID: 37882609 PMCID: PMC10638006 DOI: 10.1093/europace/euad316] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 08/07/2023] [Accepted: 09/24/2023] [Indexed: 10/27/2023] Open
Abstract
AIMS Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.
Collapse
Affiliation(s)
- Zaki Akhtar
- Department of Cardiology, St George’s University Hospital, London, UK
| | | | - Georgios Georgiopoulos
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Clinical Therapeutics, National and Kapodistrian University of Athens, Athens, Greece
| | - Christoph T Starck
- Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
| | - Lisa W M Leung
- Department of Cardiology, St George’s University Hospital, London, UK
| | - Sun Y Lee
- Department of Medicine, San Joaquin General Hospital, French Camp, CA, USA
| | - Byron K Lee
- Division of Cardiology, University of California, San Francisco, CA, USA
| | | | - Manav Sohal
- Department of Cardiology, St George’s University Hospital, London, UK
| | - Mark M Gallagher
- Department of Cardiology, St George’s University Hospital, London, UK
| |
Collapse
|
2
|
Lakkireddy DR, Segar DS, Sood A, Wu M, Rao A, Sohail MR, Pokorney SD, Blomström-Lundqvist C, Piccini JP, Granger CB. Early Lead Extraction for Infected Implanted Cardiac Electronic Devices: JACC Review Topic of the Week. J Am Coll Cardiol 2023; 81:1283-1295. [PMID: 36990548 DOI: 10.1016/j.jacc.2023.01.038] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 01/04/2023] [Accepted: 01/18/2023] [Indexed: 03/31/2023]
Abstract
Infection remains a serious complication associated with the cardiac implantable electronic devices (CIEDs), leading to substantial clinical and economic burden globally. This review assesses the burden of cardiac implantable electronic device infection (CIED-I), evidence for treatment recommendations, barriers to early diagnosis and appropriate therapy, and potential solutions. Multiple clinical practice guidelines recommended complete system and lead removal for CIED-I when appropriate. CIED extraction for infection has been consistently reported with high success, low complication, and very low mortality rates. Complete and early extraction was associated with significantly better clinical and economic outcome compared with no or late extraction. However, significant gaps in knowledge and poor recommendation compliance have been reported. Barriers to optimal management may include diagnostic delay, knowledge gaps, and limited access to expertise. A multipronged approach, including education of all stakeholders, a CIED-I alert system, and improving access to experts, could help bring paradigm shift in the treatment of this serious condition.
Collapse
Affiliation(s)
| | - Douglas S Segar
- Ascension Heart Center of Indiana, Indianapolis, Indiana, USA
| | - Ami Sood
- Philips Image Guided Therapy Corporation, Colorado Springs, Colorado, USA
| | | | - Archana Rao
- Department of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
| | - M Rizwan Sohail
- Section of Infectious Diseases, Department of Medicine, Baylor College of Medicine, Houston, Texas, USA
| | - Sean D Pokorney
- Duke University Medical Center and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA
| | - Carina Blomström-Lundqvist
- Department of Cardiology, School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden; Department of Medical Science, Uppsala University, Uppsala, Sweden
| | - Jonathan P Piccini
- Duke University Medical Center and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA
| | - Christopher B Granger
- Duke University Medical Center and Duke Clinical Research Institute, Duke University, Durham, North Carolina, USA
| |
Collapse
|
3
|
Efficacy and mortality of rotating sheaths versus laser sheaths for transvenous lead extraction: a meta-analysis. J Interv Card Electrophysiol 2021:10.1007/s10840-021-01076-x. [PMID: 34839431 DOI: 10.1007/s10840-021-01076-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 09/22/2021] [Indexed: 10/19/2022]
Abstract
BACKGROUND Rotating and laser sheaths are both routinely used in transvenous lead extraction (TLE) which can lead to catastrophic complications including death. The efficacy and risk of each approach are uncertain. To perform a meta-analysis to compare success and mortality rates associated with rotating and laser sheaths. METHODS We searched electronic academic databases for case series of consecutive patients and randomized controlled trials published 1998-2017 describing the use of rotating and laser sheaths for TLE. Among 48 studies identified, rotating sheaths included 1,094 patients with 1,955 leads in 14 studies, and laser sheaths included 7,775 patients with 12,339 leads in 34 studies. Patients receiving rotating sheaths were older (63 versus 60 years old) and were more often male (74% versus 72%); CRT-P/Ds were more commonly extracted using rotating sheaths (12% versus 7%), whereas ICDs were less common (37% versus 42%), p > 0.05 for all. Infection as an indication for lead extraction was higher in the rotating sheath group (59.8% versus 52.9%, p = 0.002). The mean time from initial lead implantation was 7.2 years for rotating sheaths and 6.3 years for laser sheaths (p > 0.05). RESULTS Success rates for complete removal of transvenous leads were 95.1% in rotating sheaths and 93.4% in laser sheaths (p < 0.05). There was one death among 1,094 patients (0.09%) in rotating sheaths and 66 deaths among 7,775 patients (0.85%) in laser sheaths, translating to a 9.3-fold higher risk of death with laser sheaths (95% CI 1.3 to 66.9, p = 0.01). CONCLUSIONS Laser sheaths were associated with lower complete lead removal rate and a 9.3-fold higher risk of death.
Collapse
|
4
|
Nubila BCLSD, Lacerda GDC, Rey HCV, Barbosa RM. Percutaneous Removal of Cardiac Leads in a Single Center in South America. Arq Bras Cardiol 2021; 116:908-916. [PMID: 34008813 PMCID: PMC8121483 DOI: 10.36660/abc.20190726] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Revised: 02/29/2020] [Accepted: 04/08/2020] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND In the last decade, the number of cardiac electronic devices has risen considerably and consequently the occasional need for their removal. Concurrently, the transvenous lead removal became a safe procedure that could prevent open-heart surgery. OBJECTIVE The primary objective of this study was to describe the successful performance and the complication rates of pacemaker removals in a Brazilian public hospital. Our secondary aim was to describe the variables associated to successes and complications. METHODS A retrospective case series was conducted in patients submitted to pacemaker removal in a Brazilian public hospital from January 2013 to June 2018. Removal, explant, extraction, success and complication rates were defined by the 2017 Heart Rhythm Society Guideline. Categorical variables were compared using x2 or Fisher's tests, while continuous variables were compared by unpaired tests. A p-value of 0.05 was considered statistically significant. RESULTS Cardiac device removals were performed in 61 patients, of which 51 were submitted to lead extractions and 10 to lead explants. In total, 128 leads were removed. Our clinical success rate was 100% in the explant group and 90.2% in the extraction one (p=0.58). Major complications were observed in 6.6% patients. Procedure failure was associated to older right ventricle (p=0.05) and atrial leads (p=0,04). Procedure duration (p=0.003) and need for blood transfusion (p<0,001) were associated to more complications. CONCLUSION Complications and clinical success were observed in 11.5% and 91.8% of the population, respectively. Removal of older atrial and ventricular leads were associated with lower success rates. Longer procedures and blood transfusions were associated with complications.
Collapse
Affiliation(s)
- Bruna Costa Lemos Silva Di Nubila
- Instituto Nacional de CardiologiaRio de JaneiroRJBrasilInstituto Nacional de Cardiologia, Rio de Janeiro, RJ - Brasil
- Hospital Pró-CardíacoRio de JaneiroRJBrasilHospital Pró-Cardíaco, Rio de Janeiro, RJ - Brasil
| | - Gustavo de Castro Lacerda
- Instituto Nacional de CardiologiaRio de JaneiroRJBrasilInstituto Nacional de Cardiologia, Rio de Janeiro, RJ - Brasil
| | - Helena Cramer Veiga Rey
- Instituto Nacional de CardiologiaRio de JaneiroRJBrasilInstituto Nacional de Cardiologia, Rio de Janeiro, RJ - Brasil
| | - Rodrigo Minati Barbosa
- Instituto Nacional de CardiologiaRio de JaneiroRJBrasilInstituto Nacional de Cardiologia, Rio de Janeiro, RJ - Brasil
| |
Collapse
|
5
|
Defaye P, Diemberger I, Rinaldi CA, Hakmi S, Nof E. Mortality during transvenous lead extraction: is there a difference between laser sheaths and rotating sheaths? Europace 2020; 22:989. [PMID: 32087009 DOI: 10.1093/europace/euaa032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Accepted: 01/21/2020] [Indexed: 11/14/2022] Open
Affiliation(s)
- Pascal Defaye
- Arrhythmia Department, Cardiology, University Hospital of Grenoble Alpes, 38043 Grenoble, France
| | - Igor Diemberger
- Department of Cardiology, Cardio Thoracic Vascular Building n23, University of Bologna, S.Orsola-Malpighi Hospital, Via Massarenti 9, 40138 Blogna, Italy
| | | | - Samer Hakmi
- Department of Cardiovascular Surgery, Asklepios Clinic St. Georg, Lohmuehlenstrasse 5, 20099 Hamburg, Germany
| | - Eyal Nof
- Davidal Arrythmia Center, Leviev Heart Center, Sheba Medical Center, Tel Hashomer, Israel
| |
Collapse
|
6
|
Migliore F, Testolina M, Sagone A, Carretta D, Agricola T, Rovaris G, Piazzi E, Facchin D, Lazzari M, Zorzi A, Melillo F, Cataldi C, Marzi A, Bottio T, Tarzia V, Gerosa G, Iliceto S, Bertaglia E, Mazzone P. Multicenter experience with the Evolution RL mechanical sheath for lead extraction using a stepwise approach: Safety, effectiveness, and outcome. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2019; 42:989-997. [DOI: 10.1111/pace.13700] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 03/18/2019] [Accepted: 04/15/2019] [Indexed: 12/22/2022]
Affiliation(s)
- Federico Migliore
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Martina Testolina
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Antonio Sagone
- Policlinico IRCCS Multimedica Sesto San Giovanni Milano Italy
| | - Domenico Carretta
- Unit of Cardiovascular Diseases, Azienda Ospedaliera UniversitariaOspedale Policlinico Consorziale Bari Italy
| | - Tullio Agricola
- Electrophysiology Unit“Spirito Santo” Hospital Pescara Italy
| | - Giovanni Rovaris
- Interventional Electrophysiology UnitSan Gerardo Hospital Monza Italy
| | - Elena Piazzi
- Interventional Electrophysiology UnitSan Gerardo Hospital Monza Italy
| | | | - Manuel Lazzari
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Alessandro Zorzi
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Francesco Melillo
- Department of Cardiology and Cardiothoracic Surgery, Arrhythmia Unit and Electrophysiology LaboratoriesOspedale San Raffaele Milan Italy
| | - Claudia Cataldi
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Alessandra Marzi
- Department of Cardiology and Cardiothoracic Surgery, Arrhythmia Unit and Electrophysiology LaboratoriesOspedale San Raffaele Milan Italy
| | - Tomaso Bottio
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Vincenzo Tarzia
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Gino Gerosa
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Sabino Iliceto
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Emanuele Bertaglia
- Department of Cardiac, Thoracic and Vascular SciencesUniversity of Padova Padova Italy
| | - Patrizio Mazzone
- Department of Cardiology and Cardiothoracic Surgery, Arrhythmia Unit and Electrophysiology LaboratoriesOspedale San Raffaele Milan Italy
| |
Collapse
|
7
|
Sharma S, Ekeruo IA, Nand NP, Sundara Raman A, Zhang X, Reddy SK, Hariharan R. Safety and Efficacy of Transvenous Lead Extraction Utilizing the Evolution Mechanical Lead Extraction System. JACC Clin Electrophysiol 2018; 4:212-220. [DOI: 10.1016/j.jacep.2017.12.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 11/30/2017] [Accepted: 12/07/2017] [Indexed: 11/17/2022]
|
8
|
Retiro endovascular de electrodos cardiacos con sistema mecánico rotacional. Complicaciones y potenciales soluciones a propósito de un caso clínico. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2017; 87:236-238. [DOI: 10.1016/j.acmx.2017.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2016] [Revised: 02/28/2017] [Accepted: 03/01/2017] [Indexed: 11/24/2022] Open
|
9
|
Cronin EM. Coronary Venous Lead Extraction. J Innov Card Rhythm Manag 2017; 8:2758-2764. [PMID: 32494456 PMCID: PMC7252920 DOI: 10.19102/icrm.2017.080604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2017] [Accepted: 04/18/2017] [Indexed: 11/06/2022] Open
Abstract
The increasing number of cardiac resynchronization therapy devices implanted, coupled with the increasing incidence of cardiac implantable electronic device infection, has led to a greater need for extraction of coronary venous pacing leads. The objectives of this study were to review the indications, techniques and published results of coronary venous lead extraction. In this study, we searched PubMed using the search terms "lead extraction," "coronary sinus," "coronary venous," "pacing," and "cardiac resynchronization therapy" for relevant papers. The reference lists of relevant articles were also searched, and personal experience was drawn upon. Published success rates and complications were found to be similar to those reported for non-coronary venous leads in experienced centers. However, reimplantation success differs and can be limited by vessel occlusion postextraction. The available active fixation coronary sinus lead (Attain Starfix™; Medtronic, MN, USA) is a particularly complex lead to extract, whereas limited data on the newer active fixation leads (Attain Stability™, Medtronic, MN, USA) suggest that they are less challenging to remove. The study concluded that coronary venous lead extraction presents unique challenges, especially reimplantation, that require special consideration and planning to overcome.
Collapse
Affiliation(s)
- Edmond M Cronin
- Hartford HealthCare Heart and Vascular Institute at Hartford Hospital, Hartford, CT.,University of Connecticut School of Medicine, Farmington, CT
| |
Collapse
|