1
|
Zhou JE, Reddy RCK, Zhong A, Li Y, Huang Q, Lin X, Qian J, Yang C, Manke I, Chen R. Metal-Organic Framework-Based Materials for Advanced Sodium Storage: Development and Anticipation. Adv Mater 2024; 36:e2312471. [PMID: 38193792 DOI: 10.1002/adma.202312471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/16/2023] [Indexed: 01/10/2024]
Abstract
As a pioneering battery technology, even though sodium-ion batteries (SIBs) are safe, non-flammable, and capable of exhibiting better temperature endurance performance than lithium-ion batteries (LIBs), because of lower energy density and larger ionic size, they are not amicable for large-scale applications. Generally, the electrochemical storage performance of a secondary battery can be improved by monitoring the composition and morphology of electrode materials. Because more is the intricacy of a nanostructured composite electrode material, more electrochemical storage applications would be expected. Despite the conventional methods suitable for practical production, the synthesis of metal-organic frameworks (MOFs) would offer enormous opportunities for next-generation battery applications by delicately systematizing the structure and composition at the molecular level to store sodium ions with larger sizes compared with lithium ions. Here, the review comprehensively discusses the progress of nanostructured MOFs and their derivatives applied as negative and positive electrode materials for effective sodium storage in SIBs. The commercialization goal has prompted the development of MOFs and their derivatives as electrode materials, before which the synthesis and mechanism for MOF-based SIB electrodes with improved sodium storage performance are systematically discussed. Finally, the existing challenges, possible perspectives, and future opportunities will be anticipated.
Collapse
Affiliation(s)
- Jian-En Zhou
- Guangzhou Key Laboratory of Materials for Energy Conversion and Storage, Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, 510006, China
| | - R Chenna Krishna Reddy
- Guangzhou Key Laboratory of Materials for Energy Conversion and Storage, Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, 510006, China
| | - Ao Zhong
- School of Environmental and Chemical Engineering, Shanghai University, Shanghai, 200444, China
| | - Yilin Li
- Guangzhou Key Laboratory of Materials for Energy Conversion and Storage, Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, 510006, China
| | - Qianhong Huang
- Guangzhou Key Laboratory of Materials for Energy Conversion and Storage, Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, 510006, China
| | - Xiaoming Lin
- Guangzhou Key Laboratory of Materials for Energy Conversion and Storage, Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, 510006, China
| | - Ji Qian
- Beijing Key Laboratory of Environmental Science and Engineering, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Chao Yang
- School of Environmental and Chemical Engineering, Shanghai University, Shanghai, 200444, China
| | - Ingo Manke
- Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109, Berlin, Germany
| | - Renjie Chen
- Beijing Key Laboratory of Environmental Science and Engineering, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| |
Collapse
|
2
|
Runge J, Nagel JM, Blahak C, Kinfe TM, Heissler HE, Schrader C, Wolf ME, Saryyeva A, Krauss JK. Does Temporary Externalization of Electrodes After Deep Brain Stimulation Surgery Result in a Higher Risk of Infection? Neuromodulation 2024; 27:565-571. [PMID: 37804281 DOI: 10.1016/j.neurom.2023.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 08/14/2023] [Accepted: 08/22/2023] [Indexed: 10/09/2023]
Abstract
OBJECTIVES Deep brain stimulation (DBS) is a well-established surgical therapy for movement disorders that comprises implantation of stimulation electrodes and a pacemaker. These procedures can be performed separately, leaving the possibility of externalizing the electrodes for local field potential recording or testing multiple targets for therapeutic efficacy. It is still debated whether the temporary externalization of DBS electrodes leads to an increased risk of infection. We therefore aimed to assess the risk of infection during and after lead externalization in DBS surgery. MATERIALS AND METHODS In this retrospective study, we analyzed a consecutive series of 624 DBS surgeries, including 266 instances with temporary externalization of DBS electrodes for a mean of 6.1 days. Patients were available for follow-up of at least one year, except in 15 instances. In 14 patients with negative test stimulation, electrodes were removed. All kinds of infections related to implantation of the neurostimulation system were accounted for. RESULTS Overall, infections occurred in 22 of 624 surgeries (3.5%). Without externalization of electrodes, infections were noted after 7 of 358 surgeries (2.0%), whereas with externalization, 15 of 252 infections were found (6.0%). This difference was significant (p = 0.01), but it did not reach statistical significance when comparing groups within different diagnoses. The rate of infection with externalized electrodes was highest in psychiatric disorders (9.1%), followed by Parkinson's disease (7.3%), pain (5.7%), and dystonia (5.5%). The duration of the externalization of the DBS electrodes was comparable in patients who developed an infection (6.1 ± 3.1 days) with duration in those who did not (6.0 ± 3.5 days). CONCLUSIONS Although infection rates were relatively low in our study, there was a slightly higher infection rate when DBS electrodes were externalized. On the basis of our results, the indication for electrode externalization should be carefully considered, and patients should be informed about the possibility of a higher infection risk when externalization of DBS electrodes is planned.
Collapse
Affiliation(s)
- Joachim Runge
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany.
| | - Johanna M Nagel
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| | | | - Thomas M Kinfe
- Division of Functional Neurosurgery, Friedrich-Alexander University, Erlangen-Nürnberg, Germany
| | - Hans E Heissler
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| | | | - Marc E Wolf
- Department of Neurology, Katharinenhospital Stuttgart, Stuttgart, Germany
| | - Assel Saryyeva
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| | - Joachim K Krauss
- Department of Neurosurgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
3
|
Shin SC, Cheon YI, Lee M, Sung ES, Lee JC, Kim M, Kim BH, Lee BJ. Normative electromyography data and influencing factors in intraoperative neuromonitoring using adhesive skin electrodes during thyroid surgery. Gland Surg 2024; 13:351-357. [PMID: 38601295 PMCID: PMC11002475 DOI: 10.21037/gs-23-428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 02/01/2024] [Indexed: 04/12/2024]
Abstract
Background Skin electrodes have been reported to be a useful alternative recording method for intraoperative neuromonitoring (IONM) and show typical electromyography (EMG) waveforms while overcoming the shortcomings of the EMG endotracheal tube. However, the skin electrodes showed relatively lower evoked amplitudes than other recording methods. In this study, we analyzed normative EMG data using skin electrodes and factors that affect the evoked amplitude of thyroid IONM. Methods In total, 167 patients [242 nerves at risk (NAR)] who underwent thyroidectomy under IONM with adhesive skin electrodes were analyzed. A pair of skin electrodes was attached to the lateral border of the lamina of the thyroid cartilage. Evoked EMG data, including mean amplitude and latency, obtained after stimulation of the recurrent laryngeal nerve (RLN) and vagus nerve (VN), were collected and analyzed. Results The mean amplitudes of RLN and VN recorded via skin electrodes were 255.48±96.53 and 236.15±69.72 μV, respectively. The mean latency of the right and left RLN was 3.22±0.03 and 3.49±0.08 mS, respectively. The mean latency of the right and left VN was 5.37±0.80 and 7.57±0.10 mS, respectively. The mean amplitude was significantly lower in the obesity, male, and total thyroidectomy (TT) groups. As body mass index (BMI) and age increased, the amplitude of EMG tended to decrease significantly. Conclusions The evoked amplitude recorded with the skin electrodes was relatively low. A larger surgical extent, obesity, male sex, and age >55 years showed significantly lower evoked amplitudes.
Collapse
Affiliation(s)
- Sung-Chan Shin
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| | - Yong-Il Cheon
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| | - Minhyung Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Gyeongsangnam-do, Republic of Korea
| | - Eui-Suk Sung
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Gyeongsangnam-do, Republic of Korea
| | - Jin-Choon Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Gyeongsangnam-do, Republic of Korea
| | - Mijin Kim
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Pusan National University College of Medicine, Pusan National University Hospital, Busan, Republic of Korea
| | - Bo Hyun Kim
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
- Division of Endocrinology and Metabolism, Department of Internal Medicine, Pusan National University College of Medicine, Pusan National University Hospital, Busan, Republic of Korea
| | - Byung-Joo Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, College of Medicine, Pusan National University, Busan, Republic of Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| |
Collapse
|
4
|
Gentile M, Bellani S, Zappia MI, Gamberini A, Mastronardi V, Abruzzese M, Gabatel L, Pasquale L, Marras S, Bagheri A, Beydaghi H, Papadopoulou EL, Lanzani G, Bonaccorso F. Hydrogen-Assisted Thermal Treatment of Electrode Materials for Electrochemical Double-Layer Capacitors. ACS Appl Mater Interfaces 2024; 16:13706-13718. [PMID: 38458613 PMCID: PMC10958450 DOI: 10.1021/acsami.3c18629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/21/2024] [Accepted: 02/21/2024] [Indexed: 03/10/2024]
Abstract
The capacitance of electrode materials used in electrochemical double-layer capacitors (EDLCs) is currently limited by several factors, including inaccessible isolated micropores in high-surface area carbons, the finite density of states resulting in a quantum capacitance in series to Helmholtz double-layer capacitance, and the presence of surface impurities, such as functional groups and adsorbed species. To unlock the full potential of EDLC active materials and corresponding electrodes, several post-production treatments are commonly proposed to improve their capacitance and, thus, the energy density of the corresponding devices. In this work, we report a systematic study of the effect of a prototypical treatment, namely H2-assisted thermal treatment, on the chemical, structural, and thermal properties of activated carbon and corresponding electrodes. By combining multiple characterization techniques, we clarify the actual origins of the improvement of the performance (e.g., > +35% energy density for the investigated power densities in the 0.5-45 kW kg-1 range) of the EDLCs based on treated electrodes compared to the case based on the pristine electrodes. Contrary to previous works supporting a questionable graphitization of the activated carbon at temperatures <1000 °C, we found that a "surface graphitization" of the activated carbon, detected by spectroscopic analysis, is mainly associated with the desorption of surface contaminants. The elimination of surface impurities, including adsorbed species, improves the surface capacitance of the activated carbon (CsurfAC) by +37.1 and +36.3% at specific currents of 1 and 10 A g-1, respectively. Despite the presence of slight densification of the activated carbon upon the thermal treatment, the latter still improves the cell gravimetric capacitance normalized on the mass of the activated carbon only (CgAC), e.g., + 28% at 1 A g-1. Besides, our holistic approach identifies the change in the active material and binder contents as a concomitant cause of the increase of cell gravimetric capacitance (Cg), accounting for the mass of all of the electrode materials measured for treated electrodes compared to pristine ones. Overall, this study provides new insights into the relationship between the modifications of the electrode materials induced by H2-assisted thermal treatments and the performance of the resulting EDLCs.
Collapse
Affiliation(s)
- Matteo Gentile
- BeDimensional
S.p.A., Via Lungotorrente
Secca 30R, Genova 16163, Italy
- Dipartimento
di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy
| | | | | | - Agnese Gamberini
- BeDimensional
S.p.A., Via Lungotorrente
Secca 30R, Genova 16163, Italy
| | | | - Matteo Abruzzese
- BeDimensional
S.p.A., Via Lungotorrente
Secca 30R, Genova 16163, Italy
| | - Luca Gabatel
- BeDimensional
S.p.A., Via Lungotorrente
Secca 30R, Genova 16163, Italy
- Department
of Mechanical, Energy, Management and Transport Engineering - DIME, Università di Genova, Via all’Opera Pia 15, Genova 16145, Italy
| | - Lea Pasquale
- Materials
Characterization Facility, Istituto Italiano
di Tecnologia, Via Morego 30, Genova 16163, Italy
| | - Sergio Marras
- Materials
Characterization Facility, Istituto Italiano
di Tecnologia, Via Morego 30, Genova 16163, Italy
| | - Ahmad Bagheri
- Graphene
Laboratories, Istituto Italiano di Tecnologia, Via Morego 30, Genoa 16163, Italy
- Center for
Advancing Electronics Dresden (CFAED) & Faculty of Chemistry and
Food Chemistry, Technische Universität
Dresden, Dresden 01062, Germany
| | - Hossein Beydaghi
- BeDimensional
S.p.A., Via Lungotorrente
Secca 30R, Genova 16163, Italy
| | | | - Guglielmo Lanzani
- Dipartimento
di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy
- Center
for Nano Science and Technology @PoliMi, Istituto Italiano di Tecnologia, Via Pascoli 70/3, Milano 20133, Italy
| | - Francesco Bonaccorso
- BeDimensional
S.p.A., Via Lungotorrente
Secca 30R, Genova 16163, Italy
- Graphene
Laboratories, Istituto Italiano di Tecnologia, Via Morego 30, Genoa 16163, Italy
| |
Collapse
|
5
|
Alfano G, Morisi N, Giovanella S, Frisina M, Amurri A, Tei L, Ferri M, Ligabue G, Donati G. Risk of infections related to endovascular catheters and cardiac implantable devices in hemodialysis patients. J Vasc Access 2024:11297298241240502. [PMID: 38506890 DOI: 10.1177/11297298241240502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/21/2024] Open
Abstract
Patients requiring dialysis are extremely vulnerable to infectious diseases. The high burden of comorbidities and weakened immune system due to uremia and previous immunosuppressive therapy expose the patient on dialysis to more infectious events than the general population. The infectious risk is further increased by the presence of endovascular catheters and implantable cardiologic devices. The former is generally placed as urgent vascular access for dialysis and in subjects requiring hemodialysis treatments without autogenous arteriovenous fistula. The high frequency of cardiovascular events also increases the likelihood of implanting indwelling implantable cardiac devices (CIED) such as pacemakers (PMs) and defibrillators (ICDs). The simultaneous presence of CVC and CIED yields an increased risk of developing severe prosthetic device-associated bloodstream infections often progressing to septicemia. Although, antibiotic therapy is the mainstay of prosthetic device-related infections, antibiotic resistance of biofilm-residing bacteria reduces the choice of infection eradication. In these cases, the resolution of the infection process relies on the removal of the prosthetic device. Compared to CVC removal, the extraction of leads is a more complex procedure and poses an increased risk of vessel tearing. As a result, the prevention of prosthetic device-related infection is of utmost importance in hemodialysis (HD) patients and relies principally on avoiding CVC as vascular access for HD and placement of a new class of wireless implantable medical devices. When the combination of CVC and CIED is inevitable, prevention of infection, mainly due translocation of skin bacteria, should be a mandatory priority for healthcare workers.
Collapse
Affiliation(s)
- Gaetano Alfano
- Nephrology, Dialysis and Kidney Transplant Unit, Azienda Ospedaliero-Universitaria di Modena, Modena, Emilia-Romagna, Italy
| | - Niccolò Morisi
- Nephrology, Dialysis and Kidney Transplant Unit, Azienda Ospedaliero-Universitaria di Modena, Modena, Emilia-Romagna, Italy
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| | - Silvia Giovanella
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| | - Monica Frisina
- Nephrology, Dialysis and Kidney Transplant Unit, Azienda Ospedaliero-Universitaria di Modena, Modena, Emilia-Romagna, Italy
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| | - Alessio Amurri
- Nephrology, Dialysis and Kidney Transplant Unit, Azienda Ospedaliero-Universitaria di Modena, Modena, Emilia-Romagna, Italy
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| | - Lorenzo Tei
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
- Nephrology and Dialysis Unit, Azienda USL di Modena, Modena, Emilia-Romagna, Italy
| | - Maria Ferri
- Nephrology, Dialysis and Kidney Transplant Unit, Azienda Ospedaliero-Universitaria di Modena, Modena, Emilia-Romagna, Italy
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| | - Giulia Ligabue
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| | - Gabriele Donati
- Nephrology, Dialysis and Kidney Transplant Unit, Azienda Ospedaliero-Universitaria di Modena, Modena, Emilia-Romagna, Italy
- Surgical, Medical, Dental and Morphological Sciences Department (CHIMOMO), University of Modena and Reggio Emilia, Modena, Emilia-Romagna, Italy
| |
Collapse
|
6
|
Chernysheva DV, Smirnova NV, Ananikov VP. Recent Trends in Supercapacitor Research: Sustainability in Energy and Materials. ChemSusChem 2024; 17:e202301367. [PMID: 37948061 DOI: 10.1002/cssc.202301367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/07/2023] [Accepted: 11/10/2023] [Indexed: 11/12/2023]
Abstract
Supercapacitors (SCs) have emerged as critical components in applications ranging from transport to wearable electronics due to their rapid charge-discharge cycles, high power density, and reliability. This review offers an analysis of recent strides in supercapacitor research, emphasizing pivotal developments in sustainability, electrode materials, electrolytes, and 'smart SCs' designed for modern microelectronics with attributes such as flexibility, stretchability, and biocompatibility. Central to this discourse are two dominant electrode materials: carbon materials (CMs), primarily in electric double layer capacitors (EDLCs), and pseudocapacitive materials, involving oxides/hydroxides, chalcogenides, metal-organic frameworks, conductive polymers and metal nitrides such as MXene. Despite EDLCs' historical use, challenges such as low energy density persist, with heteroatom introduction into the carbon lattice seen as a solution. Concurrently, pseudocapacitive materials dominate recent studies, with efficiency enhancement strategies, such as the creation of hybrids based on different types of materials, surface structural engineering and doping, under exploration. Electrolyte innovation, especially the shift towards gel polymer electrolytes for flexible SCs, and the harmonization of electrode materials with SC designs are highlighted. Emphasis is given to smart SCs with novel attributes such as self-charging, self-healing, biocompatibility, and environmentally conscious designs. In summary, the article underscores the drive in sustainable supercapacitor research to achieve high energy and power density, steering towards SCs that are efficient and versatile and involving bioderived/biocompatible SC materials. This brief review is based on selected recent references, offering depth combined with an accessible overview of the SC landscape.
Collapse
Affiliation(s)
- Daria V Chernysheva
- Platov South-Russian State Polytechnic University (NPI), Prosveschenia str. 132, Novocherkassk, 346428, Russia
| | - Nina V Smirnova
- Platov South-Russian State Polytechnic University (NPI), Prosveschenia str. 132, Novocherkassk, 346428, Russia
| | - Valentine P Ananikov
- Platov South-Russian State Polytechnic University (NPI), Prosveschenia str. 132, Novocherkassk, 346428, Russia
- Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences, Leninsky pr. 47, Moscow, 119991, Russia
| |
Collapse
|
7
|
Lv R, Luo C, Liu B, Hu K, Wang K, Zheng L, Guo Y, Du J, Li L, Wu F, Chen R. Unveiling Confinement Engineering for Achieving High-Performance Rechargeable Batteries. Adv Mater 2024:e2400508. [PMID: 38452342 DOI: 10.1002/adma.202400508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 03/03/2024] [Indexed: 03/09/2024]
Abstract
The confinement effect, restricting materials within nano/sub-nano spaces, has emerged as an innovative approach for fundamental research in diverse application fields, including chemical engineering, membrane separation, and catalysis. This confinement principle recently presents fresh perspectives on addressing critical challenges in rechargeable batteries. Within spatial confinement, novel microstructures and physiochemical properties have been raised to promote the battery performance. Nevertheless, few clear definitions and specific reviews are available to offer a comprehensive understanding and guide for utilizing the confinement effect in batteries. This review aims to fill this gap by primarily summarizing the categorization of confinement effects across various scales and dimensions within battery systems. Subsequently, the strategic design of confinement environments is proposed to address existing challenges in rechargeable batteries. These solutions involve the manipulation of the physicochemical properties of electrolytes, the regulation of electrochemical activity, and stability of electrodes, and insights into ion transfer mechanisms. Furthermore, specific perspectives are provided to deepen the foundational understanding of the confinement effect for achieving high-performance rechargeable batteries. Overall, this review emphasizes the transformative potential of confinement effects in tailoring the microstructure and physiochemical properties of electrode materials, highlighting their crucial role in designing novel energy storage devices.
Collapse
Affiliation(s)
- Ruixin Lv
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Chong Luo
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
- Advanced Technology Research Institute, Beijing Institute of Technology, Jinan, 250300, China
| | - Bingran Liu
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Kaikai Hu
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Ke Wang
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Longhong Zheng
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Yafei Guo
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Jiahao Du
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Li Li
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
- Advanced Technology Research Institute, Beijing Institute of Technology, Jinan, 250300, China
- Collaborative Innovation Center of Electric Vehicles in Beijing, Beijing, 100081, China
| | - Feng Wu
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
- Advanced Technology Research Institute, Beijing Institute of Technology, Jinan, 250300, China
- Collaborative Innovation Center of Electric Vehicles in Beijing, Beijing, 100081, China
| | - Renjie Chen
- Beijing Key Laboratory of Environmental Science and Engineering, School of Material Science and Engineering, Beijing Institute of Technology, Beijing, 100081, China
- Collaborative Innovation Center of Electric Vehicles in Beijing, Beijing, 100081, China
| |
Collapse
|
8
|
Cai D, Yang Z, Tong R, Huang H, Zhang C, Xia Y. Binder-Free MOF-Based and MOF-Derived Nanoarrays for Flexible Electrochemical Energy Storage: Progress and Perspectives. Small 2024; 20:e2305778. [PMID: 37948356 DOI: 10.1002/smll.202305778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 10/09/2023] [Indexed: 11/12/2023]
Abstract
The fast development of Internet of Things and the rapid advent of next-generation versatile wearable electronics require cost-effective and highly-efficient electroactive materials for flexible electrochemical energy storage devices. Among various electroactive materials, binder-free nanostructured arrays have attracted widespread attention. Featured with growing on a conductive and flexible substrate without using inactive and insulating binders, binder-free 3D nanoarray electrodes facilitate fast electron/ion transportation and rapid reaction kinetics with more exposed active sites, maintain structure integrity of electrodes even under bending or twisted conditions, readily release generated joule heat during charge/discharge cycles and achieve enhanced gravimetric capacity of the whole device. Binder-free metal-organic framework (MOF) nanoarrays and/or MOF-derived nanoarrays with high surface area and unique porous structure have emerged with great potential in energy storage field and been extensively exploited in recent years. In this review, common substrates used for binder-free nanoarrays are compared and discussed. Various MOF-based and MOF-derived nanoarrays, including metal oxides, sulfides, selenides, nitrides, phosphides and nitrogen-doped carbons, are surveyed and their electrochemical performance along with their applications in flexible energy storage are analyzed and overviewed. In addition, key technical issues and outlooks on future development of MOF-based and MOF-derived nanoarrays toward flexible energy storage are also offered.
Collapse
Affiliation(s)
- Dongming Cai
- Hubei Key Laboratory of Energy Storage and Power Battery, School of Mathematics, Physics and Optoelectronics Engineering, Hubei University of Automotive Technology, Shiyan, 442002, P. R. China
| | - Zhuxian Yang
- Department of Engineering, Faculty of Environment, Science and Economy, University of Exeter, Exeter, EX4 4QF, UK
| | - Rui Tong
- Hubei Key Laboratory of Energy Storage and Power Battery, School of Mathematics, Physics and Optoelectronics Engineering, Hubei University of Automotive Technology, Shiyan, 442002, P. R. China
| | - Haiming Huang
- Hubei Key Laboratory of Energy Storage and Power Battery, School of Mathematics, Physics and Optoelectronics Engineering, Hubei University of Automotive Technology, Shiyan, 442002, P. R. China
| | - Chuankun Zhang
- Hubei Key Laboratory of Energy Storage and Power Battery, School of Mathematics, Physics and Optoelectronics Engineering, Hubei University of Automotive Technology, Shiyan, 442002, P. R. China
| | - Yongde Xia
- Department of Engineering, Faculty of Environment, Science and Economy, University of Exeter, Exeter, EX4 4QF, UK
| |
Collapse
|
9
|
Kim S, Zhang Y, Wang H, Adams TE, Pol VG. Enabling Extreme Low-Temperature (≤ -100 °C) Battery Cycling with Niobium Tungsten Oxides Electrode and Tailored Electrolytes. Small 2024; 20:e2306438. [PMID: 37847910 DOI: 10.1002/smll.202306438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 10/02/2023] [Indexed: 10/19/2023]
Abstract
The degradation of current Li-ion batteries (LIBs) hinders their use in electronic devices, electric vehicles, and other applications at low temperatures, particularly in extreme environments like the polar regions and outer space. This study presents a pseudocapacitive-type niobium tungsten oxides (NbWO) electrode material combined with tailored electrolytes, enabling extreme low-temperature battery cycling for the first time. The synthesized NbWO material exhibits analogous structural properties to previous studies. Its homogenous atom distribution can further facilitate Li+ diffusion, while its pseudocapacitive Li+ storage mechanism enables faster Li+ reactions. Notably, the NbWO electrode material exhibits remarkable battery performance even at -60 and -100 °C, showcasing capacities of ≈90 and ≈75 mAh g-1 , respectively. The electrolytes, which have demonstrated favorable Li+ transport attributes at low temperatures in the earlier investigations, now enable extreme low-temperature battery operations, a feat not achievable with either NbWO or the electrolytes independently. Moreover, the outcomes extend to -120 °C and encompass a pouch-type cell configuration at -100 °C, albeit with reduced performance. This study highlights the potential of NbWO for developing batteries for their use in extremely frigid environments.
Collapse
Affiliation(s)
- Soohwan Kim
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Yizhi Zhang
- School of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Haiyan Wang
- School of Materials Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Thomas E Adams
- Naval Surface Warfare Center, Crane Division, Crane, IN, 47522, USA
| | - Vilas G Pol
- Davidson School of Chemical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| |
Collapse
|
10
|
Lam DV, Lindemann M, Yang K, Liu DX, Ludwig KA, Shoffstall AJ. An Open-Source 3D-Printed Hindlimb Stabilization Apparatus for Reliable Measurement of Stimulation-Evoked Ankle Flexion in Rat. eNeuro 2024; 11:ENEURO.0305-23.2023. [PMID: 38164555 PMCID: PMC10918511 DOI: 10.1523/eneuro.0305-23.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 11/09/2023] [Accepted: 11/27/2023] [Indexed: 01/03/2024] Open
Abstract
Currently there are numerous methods to evaluate peripheral nerve stimulation interfaces in rats, with stimulation-evoked ankle torque being one of the most prominent. Commercial rat ankle torque measurement systems and custom one-off solutions have been published in the literature. However, commercial systems are proprietary and costly and do not allow for customization. One-off lab-built systems have required specialized machining expertise, and building plans have previously not been made easily accessible. Here, detailed building plans are provided for a low-cost, open-source, and basic ankle torque measurement system from which additional customization can be made. A hindlimb stabilization apparatus was developed to secure and stabilize a rat's hindlimb, while allowing for simultaneous ankle-isometric torque and lower limb muscle electromyography (EMG). The design was composed mainly of adjustable 3D-printed components to accommodate anatomical differences between rat hindlimbs. Additionally, construction and calibration procedures of the rat hindlimb stabilization apparatus were demonstrated in this study. In vivo torque measurements were reliably acquired and corresponded to increasing stimulation amplitudes. Furthermore, implanted leads used for intramuscular EMG recordings complemented torque measurements and were used as an additional functional measurement in evaluating the performance of a peripheral nerve stimulation interface. In conclusion, an open-source and noninvasive platform, made primarily with 3D-printed components, was constructed for reliable data acquisition of evoked motor activity in rat models. The purpose of this apparatus is to provide researchers a versatile system with adjustable components that can be tailored to meet user-defined experimental requirements when evaluating motor function of the rat hindlimbs.
Collapse
Affiliation(s)
- Danny V Lam
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland 44106, Ohio
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland 44106, Ohio
| | - Madeline Lindemann
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland 44106, Ohio
| | - Kevin Yang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland 44106, Ohio
| | - Derrick X Liu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland 44106, Ohio
| | - Kip A Ludwig
- Department of Neurosurgery, University of Wisconsin-Madison, Madison 53705, Wisconsin
| | - Andrew J Shoffstall
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland 44106, Ohio
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland 44106, Ohio
| |
Collapse
|
11
|
Rappel WJ, Baykaner T, Zaman J, Ganesan P, Rogers AJ, Narayan SM. Spatially Conserved Spiral Wave Activity During Human Atrial Fibrillation. Circ Arrhythm Electrophysiol 2024; 17:e012041. [PMID: 38348685 PMCID: PMC10950516 DOI: 10.1161/circep.123.012041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 01/17/2024] [Indexed: 03/21/2024]
Abstract
BACKGROUND Atrial fibrillation is the most common cardiac arrhythmia in the world and increases the risk for stroke and morbidity. During atrial fibrillation, the electric activation fronts are no longer coherently propagating through the tissue and, instead, show rotational activity, consistent with spiral wave activation, focal activity, collision, or partial versions of these spatial patterns. An unexplained phenomenon is that although simulations of cardiac models abundantly demonstrate spiral waves, clinical recordings often show only intermittent spiral wave activity. METHODS In silico data were generated using simulations in which spiral waves were continuously created and annihilated and in simulations in which a spiral wave was intermittently trapped at a heterogeneity. Clinically, spatio-temporal activation maps were constructed using 60 s recordings from a 64 electrode catheter within the atrium of N=34 patients (n=24 persistent atrial fibrillation). The location of clockwise and counterclockwise rotating spiral waves was quantified and all intervals during which these spiral waves were present were determined. For each interval, the angle of rotation as a function of time was computed and used to determine whether the spiral wave returned in step or changed phase at the start of each interval. RESULTS In both simulations, spiral waves did not come back in phase and were out of step." In contrast, spiral waves returned in step in the majority (68%; P=0.05) of patients. Thus, the intermittently observed rotational activity in these patients is due to a temporally and spatially conserved spiral wave and not due to ones that are newly created at the onset of each interval. CONCLUSIONS Intermittency of spiral wave activity represents conserved spiral wave activity of long, but interrupted duration or transient spiral activity, in the majority of patients. This finding could have important ramifications for identifying clinically important forms of atrial fibrillation and in guiding treatment.
Collapse
Affiliation(s)
| | - Tina Baykaner
- Department of Medicine, Stanford University, Palo Alto
| | - Junaid Zaman
- Department of Cardiovascular Medicine, University of Southern California, Los Angeles, CA
| | | | | | | |
Collapse
|
12
|
Li H, Wang J, Warr GG, Atkin R. Effect of Potential on the Nanostructure Dynamics of Ethylammonium Nitrate at a Graphite Electrode. Small 2024; 20:e2306011. [PMID: 37806754 DOI: 10.1002/smll.202306011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/20/2023] [Indexed: 10/10/2023]
Abstract
Video-rate atomic force microscopy (AFM) is used to study the near-surface nanostructure dynamics of the ionic liquid ethylammonium nitrate (EAN) at a highly oriented pyrolytic graphite (HOPG) electrode as a function of potential in real-time for the first time. The effects of varying the surface potential and adding 10 wt% water on the nanostructure diffusion coefficient are probed. For both EAN and the 90 wt% EAN-water mixture, disk-like features ≈9 nm in diameter and 1 nm in height form above the Stern layer at all potentials. The nanostructure diffusion coefficient increases with potential (from OCP -0.5 V to OCP +0.5 V) and with added water. Nanostructure dynamics depends on both the magnitude and direction of the potential change. Upon switching the potential from OCP -0.5 V to OCP +0.5 V, a substantial increase in the diffusion coefficients is observed, likely due to the absence of solvophobic interactions between the nitrate (NO3 - ) anions and the ethylammonium (EA+ ) cations in the near-surface region. When the potential is reversed, EA+ is attracted to the Stern layer to replace NO3 - , but its movement is hindered by solvophobic attractions. The outcomes will aid applications, including electrochemical devices, catalysts, and lubricants.
Collapse
Affiliation(s)
- Hua Li
- School of Molecular Sciences, The University of Western Australia, Perth, Western Australia, 6009, Australia
- Centre for Microscopy, Characterisation and Analysis, The University of Western Australia, Perth, Western Australia, 6009, Australia
| | - Jianan Wang
- School of Molecular Sciences, The University of Western Australia, Perth, Western Australia, 6009, Australia
| | - Gregory G Warr
- School of Chemistry and Sydney Nano Institute, The University of Sydney, Sydney, New South Wales, 2006, Australia
| | - Rob Atkin
- School of Molecular Sciences, The University of Western Australia, Perth, Western Australia, 6009, Australia
| |
Collapse
|
13
|
Du K, Zhang D, Zhang S, Tam KC. Advanced Functionalized Materials Based on Layer-by-Layer Assembled Natural Cellulose Nanofiber for Electrodes: A Review. Small 2024; 20:e2304739. [PMID: 37726489 DOI: 10.1002/smll.202304739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 07/20/2023] [Indexed: 09/21/2023]
Abstract
The depletion of fossil fuel resources and its impact on the environment provide a compelling motivation for the development of sustainable energy sources to meet the increasing demand for energy. Accordingly, research and development of energy storage devices have emerged as a critical area of focus. The electrode materials are critical in the electrochemical performance of energy storage devices, such as energy storage capacity and cycle life. Cellulose nanofiber (CNF) represents an important substrate with potentials in the applications of green electrode materials due to their environmental sustainability and excellent compatibility. By utilizing the layer-by layer (LbL) process, well-defined nanoscale multilayer structure is prepared on a variety of substrates. In recent years, increasing attention has focused on electrode materials produced from LbL process on CNFs to yield electrodes with exceptional properties, such as high specific surface area, outstanding electrical conductivity, superior electrochemical activity, and exceptional mechanical stability. This review provides a comprehensive overview on the development of functional CNF via the LbL approach as electrode materials.
Collapse
Affiliation(s)
- Keke Du
- Key Laboratory of Wood Material Science and Application (Beijing Forestry University), Ministry of Education, Beijing, 100083, China
- Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing, 100083, China
| | - Dongyan Zhang
- Key Laboratory of Wood Material Science and Application (Beijing Forestry University), Ministry of Education, Beijing, 100083, China
- Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing, 100083, China
| | - Shuangbao Zhang
- Key Laboratory of Wood Material Science and Application (Beijing Forestry University), Ministry of Education, Beijing, 100083, China
- Beijing Key Laboratory of Wood Science and Engineering, Beijing Forestry University, Beijing, 100083, China
| | - Kam Chiu Tam
- Department of Chemical Engineering, Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
14
|
Taghlabi KM, Cruz-Garza JG, Hassan T, Potnis O, Bhenderu LS, Guerrero JR, Whitehead RE, Wu Y, Luan L, Xie C, Robinson JT, Faraji AH. Clinical outcomes of peripheral nerve interfaces for rehabilitation in paralysis and amputation: a literature review. J Neural Eng 2024; 21:011001. [PMID: 38237175 DOI: 10.1088/1741-2552/ad200f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 01/18/2024] [Indexed: 02/02/2024]
Abstract
Peripheral nerve interfaces (PNIs) are electrical systems designed to integrate with peripheral nerves in patients, such as following central nervous system (CNS) injuries to augment or replace CNS control and restore function. We review the literature for clinical trials and studies containing clinical outcome measures to explore the utility of human applications of PNIs. We discuss the various types of electrodes currently used for PNI systems and their functionalities and limitations. We discuss important design characteristics of PNI systems, including biocompatibility, resolution and specificity, efficacy, and longevity, to highlight their importance in the current and future development of PNIs. The clinical outcomes of PNI systems are also discussed. Finally, we review relevant PNI clinical trials that were conducted, up to the present date, to restore the sensory and motor function of upper or lower limbs in amputees, spinal cord injury patients, or intact individuals and describe their significant findings. This review highlights the current progress in the field of PNIs and serves as a foundation for future development and application of PNI systems.
Collapse
Affiliation(s)
- Khaled M Taghlabi
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Jesus G Cruz-Garza
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Taimur Hassan
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Ojas Potnis
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Engineering Medicine, Texas A&M University, Houston, TX 77030, United States of America
| | - Lokeshwar S Bhenderu
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Jaime R Guerrero
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Rachael E Whitehead
- Department of Academic Affairs, Houston Methodist Academic Institute, Houston, TX 77030, United States of America
| | - Yu Wu
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Lan Luan
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Chong Xie
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Jacob T Robinson
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Amir H Faraji
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| |
Collapse
|
15
|
Ding L, Patel A, Shankar S, Driscoll N, Zhou C, Rex TS, Vitale F, Gallagher MJ. An Open-Source Mouse Chronic EEG Array System with High-Density MXene-Based Skull Surface Electrodes. eNeuro 2024; 11:ENEURO.0512-22.2023. [PMID: 38388423 PMCID: PMC10884564 DOI: 10.1523/eneuro.0512-22.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 11/12/2023] [Accepted: 12/18/2023] [Indexed: 02/24/2024] Open
Abstract
Electroencephalography (EEG) is an indispensable tool in epilepsy, sleep, and behavioral research. In rodents, EEG recordings are typically performed with metal electrodes that traverse the skull into the epidural space. In addition to requiring major surgery, intracranial EEG is difficult to perform for more than a few electrodes, is time-intensive, and confounds experiments studying traumatic brain injury. Here, we describe an open-source cost-effective refinement of this technique for chronic mouse EEG recording. Our alternative two-channel (EEG2) and sixteen-channel high-density EEG (HdEEG) arrays use electrodes made of the novel, flexible 2D nanomaterial titanium carbide (Ti3C2T x ) MXene. The MXene electrodes are placed on the surface of the intact skull and establish an electrical connection without conductive gel or paste. Fabrication and implantation times of MXene EEG electrodes are significantly shorter than the standard approach, and recorded resting baseline and epileptiform EEG waveforms are similar to those obtained with traditional epidural electrodes. Applying HdEEG to a mild traumatic brain injury (mTBI) model in mice of both sexes revealed that mTBI significantly increased spike-wave discharge (SWD) preictal network connectivity with frequencies of interest in the β-spectral band (12-30 Hz). These findings indicate that the fabrication of MXene electrode arrays is a cost-effective, efficient technology for multichannel EEG recording in mice that obviates the need for skull-penetrating surgery. Moreover, increased preictal β-frequency network connectivity may contribute to the development of early post-mTBI SWDs.
Collapse
Affiliation(s)
- Li Ding
- Department of Neurology, Vanderbilt University School of Medicine, Nashville 37232, Tennessee
| | - Aashvi Patel
- Department of Neurology, Vanderbilt University School of Medicine, Nashville 37232, Tennessee
| | - Sneha Shankar
- Departments of Bioengineering and Neurology, Center for Neuroengineering & Therapeutics, University of Pennsylvania, Philadelphia 19104, Pennsylvania
| | - Nicolette Driscoll
- Departments of Bioengineering and Neurology, Center for Neuroengineering & Therapeutics, University of Pennsylvania, Philadelphia 19104, Pennsylvania
| | - Chengwen Zhou
- Department of Neurology, Vanderbilt University School of Medicine, Nashville 37232, Tennessee
| | - Tonia S Rex
- Department of Ophthalmology & Visual Sciences, Vanderbilt University School of Medicine, Nashville 37232, Tennessee
| | - Flavia Vitale
- Departments of Bioengineering and Neurology, Center for Neuroengineering & Therapeutics, University of Pennsylvania, Philadelphia 19104, Pennsylvania
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia 19104, Pennsylvania
| | - Martin J Gallagher
- Department of Neurology, Vanderbilt University School of Medicine, Nashville 37232, Tennessee
- Department of Veteran's Affairs, Tennessee Valley Health System, Nashville 37212, Tennessee
| |
Collapse
|
16
|
Oldroyd P, Oldroyd S, Meng M, Makwana R, Sanger G, Bulmer D, Malliaras GG, Owens RM. Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal Tract. Adv Mater 2024:e2312735. [PMID: 38290128 DOI: 10.1002/adma.202312735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 01/15/2024] [Indexed: 02/01/2024]
Abstract
Devices interfacing with biological tissues can provide valuable insights into function, disease, and metabolism through electrical and mechanical signals. However, certain neuromuscular tissues, like those in the gastrointestinal tract, undergo significant strains of up to 40%. Conventional inextensible devices cannot capture the dynamic responses in these tissues. This study introduces electrodes made from poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and polydimethylsiloxane (PDMS) that enable simultaneous monitoring of electrical and mechanical responses of gut tissue. The soft PDMS layers conform to tissue surfaces during gastrointestinal movement. Dopants, including Capstone FS-30 and polyethylene glycol, are explored to enhance the conductivity, electrical sensitivity to strain, and stability of the PEDOT:PSS. The devices are fabricated using shadow masks and solution-processing techniques, providing a faster and simpler process than traditional clean-room-based lithography. Tested on ex vivo mouse colon and human stomach, the device recorded voltage changes of up to 300 µV during contraction and distension consistent with muscle activity, while simultaneously recording resistance changes of up to 150% due to mechanical strain. These devices detect and respond to chemical stimulants and blockers, and can induce contractions through electrical stimulation. They hold great potential for studying and treating complex disorders like irritable bowel syndrome and gastroparesis.
Collapse
Affiliation(s)
- Poppy Oldroyd
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK
| | - Sophie Oldroyd
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS, UK
| | - Michelle Meng
- Department of Pharmacology, Tennis Ct Rd, University of Cambridge, Cambridge, CB2 1PD, UK
| | - Rajesh Makwana
- Blizard Institute, Queen Mary University of London, Cambridge, E1 2AT, UK
| | - Gareth Sanger
- Blizard Institute, Queen Mary University of London, Cambridge, E1 2AT, UK
| | - David Bulmer
- Department of Pharmacology, Tennis Ct Rd, University of Cambridge, Cambridge, CB2 1PD, UK
| | - George G Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK
| | - Róisín M Owens
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS, UK
| |
Collapse
|
17
|
Pan H, Huang Y, Cen X, Zhang M, Hou J, Wu C, Dou Y, Sun B, Wang Y, Zhang B, Zhang L. Hollow Carbon and MXene Dual-Reinforced MoS 2 with Enlarged Interlayers for High-Rate and High-Capacity Sodium Storage Systems. Adv Sci (Weinh) 2024:e2400364. [PMID: 38251278 DOI: 10.1002/advs.202400364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Indexed: 01/23/2024]
Abstract
Sodium-ion batteries (SIBs) and sodium-ion capacitors (SICs) are promising candidates for cost-effective and large-scale energy storage devices. However, sluggish kinetics and low capacity of traditional anode materials inhibit their practical applications. Herein, a novel design featuring a layer-expanded MoS2 is presented that dual-reinforced by hollow N, P-codoped carbon as the inner supporter and surface groups abundant MXene as the outer supporter, resulting in a cross-linked robust composite (NPC@MoS2 /MXene). The hollow N, P-codoped carbon effectively prevents agglomeration of MoS2 layers and facilitates shorter distances between the electrolyte and electrode. The conductive MXene outer surface envelops the NPC@MoS2 units inside, creating interconnected channels that enable efficient charge transfer and diffusion, ensuring rapid kinetics and enhanced electrode utilization. It exhibits a high reversible capacity of 453 mAh g-1 , remarkable cycling stability, and exceptional rate capability with 54% capacity retention when the current density increases from 100 to 5000 mA g-1 toward SIBs. The kinetic mechanism studies reveal that the NPC@MoS2 /MXene demonstrates a pseudocapacitance dominated hybrid sodiation/desodiation process. Coupled with active carbon (AC), the NPC@MoS2 /MXene//AC SICs achieve both high energy density of 136 Wh kg-1 at 254 W kg-1 and high-power density of 5940 W kg-1 at 27 Wh g-1 , maintaining excellent stability.
Collapse
Affiliation(s)
- Hanqing Pan
- Jiangsu Key Laboratory of Green Synthetic Chemistry for Functional Materials, School of Chemistry & Materials Science, Jiangsu Normal University, Xuzhou, Jiangsu, 221116, P. R. China
| | - Yan Huang
- Jiangsu Key Laboratory of Green Synthetic Chemistry for Functional Materials, School of Chemistry & Materials Science, Jiangsu Normal University, Xuzhou, Jiangsu, 221116, P. R. China
| | - Xinnuo Cen
- Jiangsu Key Laboratory of Green Synthetic Chemistry for Functional Materials, School of Chemistry & Materials Science, Jiangsu Normal University, Xuzhou, Jiangsu, 221116, P. R. China
| | - Ming Zhang
- Jiangsu Key Laboratory of Green Synthetic Chemistry for Functional Materials, School of Chemistry & Materials Science, Jiangsu Normal University, Xuzhou, Jiangsu, 221116, P. R. China
| | - Jianhua Hou
- College of Environmental Science and Engineering, Yangzhou University, Yangzhou, Jiangsu, 225009, P. R. China
| | - Chao Wu
- Institute of Energy Materials Science, University of Shanghai for Science and Technology, Shanghai, 200093, P. R. China
| | - Yuhai Dou
- Institute of Energy Materials Science, University of Shanghai for Science and Technology, Shanghai, 200093, P. R. China
| | - Bing Sun
- Centre for Clean Energy Technology, School of Mathematical and Physical Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Ying Wang
- Jiangsu Key Laboratory of Green Synthetic Chemistry for Functional Materials, School of Chemistry & Materials Science, Jiangsu Normal University, Xuzhou, Jiangsu, 221116, P. R. China
| | - Binwei Zhang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing, 401331, P. R. China
- Center of Advanced Electrochemical Energy, Institute of Advanced Interdisciplinary Studies, Chongqing University, Chongqing, 401331, P. R. China
| | - Lei Zhang
- Centre for Catalysis and Clean Energy, Gold, Coast Campus, Griffith University, Gold Coast, QLD, 4222, Australia
| |
Collapse
|
18
|
Mukherjee S, Benavidez E, Crumb M, Calta NP. An Electrical Resistance Diagnostic for Conductivity Monitoring in Laser Powder Bed Fusion. Sensors (Basel) 2024; 24:523. [PMID: 38257616 PMCID: PMC10819052 DOI: 10.3390/s24020523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 01/10/2024] [Accepted: 01/10/2024] [Indexed: 01/24/2024]
Abstract
With the growing interest in metal additive manufacturing using laser powder bed fusion (LPBF), there is a need for advanced in-situ nondestructive evaluation (NDE) methods that can dynamically monitor manufacturing process-related variations, that can be used as a feedback mechanism to further improve the manufacturing process, leading to parts with improved microstructural properties and mechanical properties. Current NDE techniques either lack sensitivity beyond build layer, are costly or time-consuming, or are not compatible for in-situ integration. In this research, we develop an electrical resistance diagnostic for in-situ monitoring of powder fused regions during laser powder bed fusion printing. The technique relies on injecting current into the build plate and detecting voltage differences from conductive variations during printing using a simple, cheap four-point electrode array directly connected to the build plate. A computational model will be utilized to determine sensitivities of the approach, and preliminary experiments will be performed during the printing process to test the overall approach.
Collapse
Affiliation(s)
- Saptarshi Mukherjee
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA; (E.B.); (M.C.); (N.P.C.)
| | | | | | | |
Collapse
|
19
|
van der Heijden P, Gilbert C, Jafari S, Lucchini MA. Multi-Channel Soft Dry Electrodes for Electrocardiography Acquisition in the Ear Region. Sensors (Basel) 2024; 24:420. [PMID: 38257511 PMCID: PMC10819754 DOI: 10.3390/s24020420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 12/22/2023] [Accepted: 01/08/2024] [Indexed: 01/24/2024]
Abstract
In-ear acquisition of physiological signals, such as electromyography (EMG), electrooculography (EOG), electroencephalography (EEG), and electrocardiography (ECG), is a promising approach to mobile health (mHealth) due to its non-invasive and user-friendly nature. By providing a convenient and comfortable means of physiological signal monitoring, in-ear signal acquisition could potentially increase patient compliance and engagement with mHealth applications. The development of reliable and comfortable soft dry in-ear electrode systems could, therefore, have significant implications for both mHealth and human-machine interface (HMI) applications. This research evaluates the quality of the ECG signal obtained with soft dry electrodes inserted in the ear canal. An earplug with six soft dry electrodes distributed around its perimeter was designed for this study, allowing for the analysis of the signal coming from each electrode independently with respect to a common reference placed at different positions on the body of the participants. An analysis of the signals in comparison with a reference signal measured on the upper right chest (RA) and lower left chest (LL) was performed. The results show three typical behaviors for the in-ear electrodes. Some electrodes have a high correlation with the reference signal directly after inserting the earplug, other electrodes need a settling time of typically 1-3 min, and finally, others never have a high correlation. The SoftPulseTM electrodes used in this research have been proven to be perfectly capable of measuring physiological signals, paving the way for their use in mHealth or HMI applications. The use of multiple electrodes distributed in the ear canal has the advantage of allowing a more reliable acquisition by intelligently selecting the signal acquisition locations or allowing a better spatial resolution for certain applications by processing these signals independently.
Collapse
Affiliation(s)
| | | | - Samira Jafari
- Dätwyler Schweiz AG, 6467 Schattdorf, Switzerland (M.A.L.)
| | | |
Collapse
|
20
|
Scarcello A, Alessandro F, Cruz Salazar Y, Arias Polanco M, Vacacela Gomez C, Tene T, Guevara M, Bellucci S, Straface S, Caputi LS. Stable Supercapacitors Based on Activated Carbon Prepared from Italian Orange Juice. Nanomaterials (Basel) 2023; 14:71. [PMID: 38202526 PMCID: PMC10780622 DOI: 10.3390/nano14010071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/23/2023] [Accepted: 12/25/2023] [Indexed: 01/12/2024]
Abstract
The development of efficient energy storage systems is critical in the transition towards sustainable energy solutions. In this context, the present work investigates the viability of using orange juice, as a promising and sustainable precursor, for the synthesis of activated carbon electrodes for supercapacitor technologies. Through the carbonization-activation process and controlling the preparation parameters (KOH ratio and activation time), we have tailored the specific surface area (SSA) and pore size distribution (PSD) of the resulting carbon materials-crucial parameters that support supercapacitive performance. Several spectroscopic, morphological, and electrochemical techniques are used to characterize the obtained carbon materials. In particular, our optimization efforts revealed that a 5:1 KOH ratio with an activation time up to 120 min produced the highest SSA of about 2203 m2/g. Employing these optimal conditions, we fabricated symmetric coin cell supercapacitors using Na2SO4 as the electrolyte, which exhibited interesting specific capacitance (~56 F/g). Durability testing over 5000 cycles sustained the durability of the as-made activated carbon electrodes, suggesting an excellent retention of specific capacitance. This study not only advances the field of energy storage by introducing a renewable material for electrode fabrication but also contributes to the broader goal of waste reduction through the repurposing of food byproducts.
Collapse
Affiliation(s)
- Andrea Scarcello
- Surface Nanoscience Group, Department of Physics, University of Calabria, 87036 Rende, Italy
- UNICARIBE Research Center, University of Calabria, 87036 Rende, Italy
| | - Francesca Alessandro
- Institute on Membrane Technology, National Research Council of Italy (CNR-ITM), Via P. Bucci 17/C, 87036 Rende, Italy
| | - Yolenny Cruz Salazar
- Surface Nanoscience Group, Department of Physics, University of Calabria, 87036 Rende, Italy
- UNICARIBE Research Center, University of Calabria, 87036 Rende, Italy
| | - Melvin Arias Polanco
- UNICARIBE Research Center, University of Calabria, 87036 Rende, Italy
- Laboratorio de Nanotecnología, Area de Ciencias Básicas y Ambientales, Instituto Tecnológico de Santo Domingo, Av. Los Próceres, Santo Domingo 10602, Dominican Republic
| | - Cristian Vacacela Gomez
- UNICARIBE Research Center, University of Calabria, 87036 Rende, Italy
- INFN-Laboratori Nazionali di Frascati, 00044 Frascati, Italy;
| | - Talia Tene
- UNICARIBE Research Center, University of Calabria, 87036 Rende, Italy
- Department of Chemistry, Universidad Tecnica Particular de Loja, Loja 110160, Ecuador
| | - Marco Guevara
- Faculty of Mechanical Engineering, Escuela Superior Politécnica de Chimborazo (ESPOCH), Riobamba 060155, Ecuador
| | | | - Salvatore Straface
- Department of Environmental Engineering (DIAm), University of Calabria, Via P. Bucci, Cubo 42B, 87036 Rende, Italy
| | - Lorenzo S. Caputi
- Surface Nanoscience Group, Department of Physics, University of Calabria, 87036 Rende, Italy
- UNICARIBE Research Center, University of Calabria, 87036 Rende, Italy
| |
Collapse
|
21
|
Prabhakar Vattikuti SV, Shim J, Rosaiah P, Mauger A, Julien CM. Recent Advances and Strategies in MXene-Based Electrodes for Supercapacitors: Applications, Challenges and Future Prospects. Nanomaterials (Basel) 2023; 14:62. [PMID: 38202517 PMCID: PMC10780966 DOI: 10.3390/nano14010062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/18/2023] [Accepted: 12/22/2023] [Indexed: 01/12/2024]
Abstract
With the growing demand for technologies to sustain high energy consumption, supercapacitors are gaining prominence as efficient energy storage solutions beyond conventional batteries. MXene-based electrodes have gained recognition as a promising material for supercapacitor applications because of their superior electrical conductivity, extensive surface area, and chemical stability. This review provides a comprehensive analysis of the recent progress and strategies in the development of MXene-based electrodes for supercapacitors. It covers various synthesis methods, characterization techniques, and performance parameters of these electrodes. The review also highlights the current challenges and limitations, including scalability and stability issues, and suggests potential solutions. The future outlooks and directions for further research in this field are also discussed, including the creation of new synthesis methods and the exploration of novel applications. The aim of the review is to offer a current and up-to-date understanding of the state-of-the-art in MXene-based electrodes for supercapacitors and to stimulate further research in the field.
Collapse
Affiliation(s)
| | - Jaesool Shim
- School of Mechanical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea; (S.V.P.V.); (J.S.)
| | - Pitcheri Rosaiah
- Department of Physics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam, Chennai 602105, India;
| | - Alain Mauger
- Institut de Minéralogie, de Physique des Matériaux et de Cosmologie (IMPMC), Sorbonne Université, UMR-CNRS 7590, 4 Place Jussieu, 75005 Paris, France;
| | - Christian M. Julien
- Institut de Minéralogie, de Physique des Matériaux et de Cosmologie (IMPMC), Sorbonne Université, UMR-CNRS 7590, 4 Place Jussieu, 75005 Paris, France;
| |
Collapse
|
22
|
Duan W, Robles UA, Poole-Warren L, Esrafilzadeh D. Bioelectronic Neural Interfaces: Improving Neuromodulation Through Organic Conductive Coatings. Adv Sci (Weinh) 2023:e2306275. [PMID: 38115740 DOI: 10.1002/advs.202306275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 11/07/2023] [Indexed: 12/21/2023]
Abstract
Integration of bioelectronic devices in clinical practice is expanding rapidly, focusing on conditions ranging from sensory to neurological and mental health disorders. While platinum (Pt) electrodes in neuromodulation devices such as cochlear implants and deep brain stimulators have shown promising results, challenges still affect their long-term performance. Key among these are electrode and device longevity in vivo, and formation of encapsulating fibrous tissue. To overcome these challenges, organic conductors with unique chemical and physical properties are being explored. They hold great promise as coatings for neural interfaces, offering more rapid regulatory pathways and clinical implementation than standalone bioelectronics. This study provides a comprehensive review of the potential benefits of organic coatings in neuromodulation electrodes and the challenges that limit their effective integration into existing devices. It discusses issues related to metallic electrode use and introduces physical, electrical, and biological properties of organic coatings applied in neuromodulation. Furthermore, previously reported challenges related to organic coating stability, durability, manufacturing, and biocompatibility are thoroughly reviewed and proposed coating adhesion mechanisms are summarized. Understanding organic coating properties, modifications, and current challenges of organic coatings in clinical and industrial settings is expected to provide valuable insights for their future development and integration into organic bioelectronics.
Collapse
Affiliation(s)
- Wenlu Duan
- The Graduate School of Biomedical Engineering, UNSW, Sydney, NSW, 2052, Australia
| | | | - Laura Poole-Warren
- The Graduate School of Biomedical Engineering, UNSW, Sydney, NSW, 2052, Australia
- Tyree Foundation Institute of Health Engineering, UNSW, Sydney, NSW, 2052, Australia
| | - Dorna Esrafilzadeh
- The Graduate School of Biomedical Engineering, UNSW, Sydney, NSW, 2052, Australia
| |
Collapse
|
23
|
Kim YS. Hydrocarbon Ionomeric Binders for Fuel Cells and Electrolyzers. Adv Sci (Weinh) 2023; 10:e2303914. [PMID: 37814366 DOI: 10.1002/advs.202303914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/08/2023] [Indexed: 10/11/2023]
Abstract
Ionomeric binders in catalyst layers, abbreviated as ionomers, play an essential role in the performance of polymer-electrolyte membrane fuel cells and electrolyzers. Due to environmental issues associated with perfluoroalkyl substances, alternative hydrocarbon ionomers have drawn substantial attention over the past few years. This review surveys literature to discuss ionomer requirements for the electrodes of fuel cells and electrolyzers, highlighting design principles of hydrocarbon ionomers to guide the development of advanced hydrocarbon ionomers.
Collapse
Affiliation(s)
- Yu Seung Kim
- MPA-11: Materials Synthesis and Integrated Devices, Los Alamos National Laboratory, Los Alamos, NM, 87545, USA
| |
Collapse
|
24
|
Indahlastari A, Dunn AL, Pedersen S, Kraft JN, Someya S, Albizu A, Woods AJ. Impact of electrode selection on modeling tDCS in the aging brain. Front Hum Neurosci 2023; 17:1274114. [PMID: 38077189 PMCID: PMC10704166 DOI: 10.3389/fnhum.2023.1274114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 11/01/2023] [Indexed: 02/12/2024] Open
Abstract
Background Person-specific computational models can estimate transcranial direct current stimulation (tDCS) current dose delivered to the brain and predict treatment response. Artificially created electrode models derived from virtual 10-20 EEG measurements are typically included in these models as current injection and removal sites. The present study directly compares current flow models generated via artificially placed electrodes ("artificial" electrode models) against those generated using real electrodes acquired from structural MRI scans ("real" electrode models) of older adults. Methods A total of 16 individualized head models were derived from cognitively healthy older adults (mean age = 71.8 years) who participated in an in-scanner tDCS study with an F3-F4 montage. Visible tDCS electrodes captured within the MRI scans were segmented to create the "real" electrode model. In contrast, the "artificial" electrodes were generated in ROAST. Percentage differences in current density were computed in selected regions of interest (ROIs) as examples of stimulation targets within an F3-F4 montage. Main results We found significant inverse correlations (p < 0.001) between median current density values and brain atrophy in both electrode pipelines with slightly larger correlations found in the artificial pipeline. The percent difference (PD) of the electrode distances between the two models predicted the median current density values computed in the ROIs, gray, and white matter, with significant correlation between electrode distance PDs and current density. The correlation between PD of the contact areas and the computed median current densities in the brain was found to be non-significant. Conclusions This study demonstrates potential discrepancies in generated current density models using real versus artificial electrode placement when applying tDCS to an older adult cohort. Our findings strongly suggest that future tDCS clinical work should consider closely monitoring and rigorously documenting electrode location during stimulation to model tDCS montages as closely as possible to actual placement. Detailed physical electrode location data may provide more precise information and thus produce more robust tDCS modeling results.
Collapse
Affiliation(s)
- Aprinda Indahlastari
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
| | - Ayden L. Dunn
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
| | - Samantha Pedersen
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
| | - Jessica N. Kraft
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
- Department of Neuroscience, College of Medicine, University of Florida, Gainesville, FL, United States
| | - Shizu Someya
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
| | - Alejandro Albizu
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
- Department of Neuroscience, College of Medicine, University of Florida, Gainesville, FL, United States
| | - Adam J. Woods
- Center for Cognitive Aging and Memory, McKnight Brain Institute, University of Florida, Gainesville, FL, United States
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
- Department of Neuroscience, College of Medicine, University of Florida, Gainesville, FL, United States
| |
Collapse
|
25
|
Alsharif SA. Nanograss-Assembled NiCo 2S 4 as an Efficient Platinum-Free Counter Electrode for Dye-Sensitized Solar Cell. Nanomaterials (Basel) 2023; 13:2896. [PMID: 37947740 PMCID: PMC10650019 DOI: 10.3390/nano13212896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 10/26/2023] [Accepted: 10/30/2023] [Indexed: 11/12/2023]
Abstract
Dye-sensitized solar cells (DSSCs) are often viewed as the potential future of photovoltaic systems and have garnered significant attention in solar energy research. In this groundbreaking research, we introduced a novel solvothermal method to fabricate a unique "grass-like" pattern on fluorine-doped tin oxide glass (FTO), specifically designed for use as a counter electrode in dye-sensitized solar cell (DSSC) assemblies. Through rigorous structural and morphological evaluations, we ascertained the successful deposition of nickel cobalt sulfide (NCS) on the FTO surface, exhibiting the desired grass-like morphology. Electrocatalytic performance assessment of the developed NCS-1 showed results that intriguingly rivaled those of the acclaimed platinum catalyst, especially during the conversion of I3 to I- as observed through cyclic voltammetry. Remarkably, when integrated into a solar cell assembly, both NCS-1 and NCS-2 electrodes exhibited encouraging power conversion efficiencies of 6.60% and 6.29%, respectively. These results become particularly noteworthy when compared to the 7.19% efficiency of a conventional Pt-based electrode under similar testing conditions. Central to the performance of the NCS-1 and NCS-2 electrodes is their unique thin and sharp grass-like morphology. This structure, vividly showcased through scanning electron microscopy, provides a vast surface area and an abundance of catalytic sites, pivotal for the catalytic reactions involving the electrolytes in DSSCs. In summation, given their innovative synthesis approach, affordability, and remarkable electrocatalytic attributes, the newly developed NCS counter electrodes stand out as potent contenders in future dye-sensitized solar cell applications.
Collapse
Affiliation(s)
- Shada A Alsharif
- University College of Umlij, University of Tabuk, Tabuk 71491, Saudi Arabia
| |
Collapse
|
26
|
Gao L, Han S, Ni H, Zhu J, Wang L, Gao S, Wang Y, Huang D, Zhao Y, Zou R. Application of neutron imaging in observing various states of matter inside lithium batteries. Natl Sci Rev 2023; 10:nwad238. [PMID: 37854950 PMCID: PMC10581545 DOI: 10.1093/nsr/nwad238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 07/30/2023] [Accepted: 08/27/2023] [Indexed: 10/20/2023] Open
Abstract
Lithium batteries have been essential technologies and become an integral part of our daily lives, powering a range of devices from phones to electric vehicles. To fully understand and optimize the performance of lithium batteries, it is necessary to investigate their internal states and processes through various characterization methods. Neutron imaging has been an indispensable complementary characterization technique to X-ray imaging or electron microscopy because of the unique interaction principle between neutrons and matter. It provides particular insights into the various states of matter inside lithium batteries, including the Li+ concentration in solid electrodes, the Li plating/stripping behavior of Li-metal anodes, the Li+ diffusion in solid ionic conductors, the distribution of liquid electrolytes and the generation of gases. This review aims to highlight the capabilities and advantages of neutron imaging in characterizing lithium batteries, as well as its current state of application in this field. Additionally, we discuss the potential of neutron imaging to contribute to the ongoing development of advanced batteries through its ability to visualize internal evolution.
Collapse
Affiliation(s)
- Lei Gao
- School of Materials Science and Engineering, Peking University, Beijing 100871, China
| | - Songbai Han
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen 518055, China
| | - Haijin Ni
- Department of Physics, Southern University of Science and Technology, Shenzhen 518055, China
| | - Jinlong Zhu
- Department of Physics, Southern University of Science and Technology, Shenzhen 518055, China
| | - Liping Wang
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen 518055, China
| | - Song Gao
- School of Materials Science and Engineering, Peking University, Beijing 100871, China
| | - Yonggang Wang
- School of Materials Science and Engineering, Peking University, Beijing 100871, China
| | - Dubin Huang
- School of Materials Science and Engineering, Peking University, Beijing 100871, China
| | - Yusheng Zhao
- Eastern Institute for Advanced Study, Ningbo 315201, China
| | - Ruqiang Zou
- School of Materials Science and Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
27
|
Desai A, Sharma A, Sundar SJ, Hsieh JK, Kondylis E, Patel A, Bulacio J, Gupta A, Jehi L, Bingaman W. The impact of skull thickness on pediatric stereoencephalography electrode implantation and technical considerations. J Neurosurg Pediatr 2023; 32:562-568. [PMID: 37728404 DOI: 10.3171/2023.6.peds2351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 06/08/2023] [Indexed: 09/21/2023]
Abstract
OBJECTIVE One consideration in pediatric stereoencephalography (SEEG) is decreased skull thicknesses compared with adults, which may limit traditional bolt-based anchoring of electrodes. The authors aimed to investigate the safety profile, complication rates, and technical adaptations of placing SEEG electrodes in pediatric patients. METHODS The authors retrospectively reviewed all patients aged 12 years or younger at the time of SEEG implantation at their institution. Postimplantation CT scans were used to measure skull thickness at the entry point of each SEEG lead. Postimplantation lead accuracy was also assessed. RESULTS Fifty-three patients were reviewed. The median skull thickness was 4.1 (interquartile range [IQR] 3.15-5.2) mm. There were 5 total complications: 1 retained bolt fragment, 3 asymptomatic subdural hematomas, and 1 asymptomatic intracranial hemorrhage. Median radial error from the lead target was 3.5 (IQR 2.24-5.25) mm. Linear regression analysis revealed that increasing skull thickness decreased the deviation from the intended target, implying an improved accuracy to target at thicker skull entry points; this trended towards improved accuracy, but did not achieve statistical significance (p = 0.54). CONCLUSIONS This study found a 1.9% hardware complication rate and a 9.4% asymptomatic hemorrhage rate. Suturing electrodes to the scalp may represent a reasonable option if there are concerns of young age or a thin skull. These data indicate that invasive SEEG evaluation is safe among patients 12 years old or younger.
Collapse
Affiliation(s)
- Ansh Desai
- 1Case Western Reserve University School of Medicine, Cleveland
| | - Akshay Sharma
- 2Department of Neurosurgery, Cleveland Clinic, Cleveland; and
| | - Swetha J Sundar
- 2Department of Neurosurgery, Cleveland Clinic, Cleveland; and
| | - Jason K Hsieh
- 2Department of Neurosurgery, Cleveland Clinic, Cleveland; and
| | | | - Arpan Patel
- 2Department of Neurosurgery, Cleveland Clinic, Cleveland; and
| | - Juan Bulacio
- 3Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio
| | - Ajay Gupta
- 3Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio
| | - Lara Jehi
- 3Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio
| | - William Bingaman
- 2Department of Neurosurgery, Cleveland Clinic, Cleveland; and
- 3Charles Shor Center for Epilepsy, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
28
|
Qin Y, Zhang Y, Zhang Y, Liu S, Guo X. Application and Development of EEG Acquisition and Feedback Technology: A Review. Biosensors (Basel) 2023; 13:930. [PMID: 37887123 PMCID: PMC10605290 DOI: 10.3390/bios13100930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/05/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023]
Abstract
This review focuses on electroencephalogram (EEG) acquisition and feedback technology and its core elements, including the composition and principles of the acquisition devices, a wide range of applications, and commonly used EEG signal classification algorithms. First, we describe the construction of EEG acquisition and feedback devices encompassing EEG electrodes, signal processing, and control and feedback systems, which collaborate to measure faint EEG signals from the scalp, convert them into interpretable data, and accomplish practical applications using control feedback systems. Subsequently, we examine the diverse applications of EEG acquisition and feedback across various domains. In the medical field, EEG signals are employed for epilepsy diagnosis, brain injury monitoring, and sleep disorder research. EEG acquisition has revealed associations between brain functionality, cognition, and emotions, providing essential insights for psychologists and neuroscientists. Brain-computer interface technology utilizes EEG signals for human-computer interaction, driving innovation in the medical, engineering, and rehabilitation domains. Finally, we introduce commonly used EEG signal classification algorithms. These classification tasks can identify different cognitive states, emotional states, brain disorders, and brain-computer interface control and promote further development and application of EEG technology. In conclusion, EEG acquisition technology can deepen the understanding of EEG signals while simultaneously promoting developments across multiple domains, such as medicine, science, and engineering.
Collapse
Affiliation(s)
- Yong Qin
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China;
| | - Yanpeng Zhang
- Beijing Perfect-Protection Technology Co., Ltd., Beijing 101601, China; (Y.Z.); (Y.Z.); (S.L.)
| | - Yan Zhang
- Beijing Perfect-Protection Technology Co., Ltd., Beijing 101601, China; (Y.Z.); (Y.Z.); (S.L.)
| | - Sheng Liu
- Beijing Perfect-Protection Technology Co., Ltd., Beijing 101601, China; (Y.Z.); (Y.Z.); (S.L.)
| | - Xiaogang Guo
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China;
| |
Collapse
|
29
|
Mi J, Chen L, Ma J, Yang K, Hou T, Liu M, Lv W, He YB. Defect Strategy in Solid-State Lithium Batteries. Small Methods 2023:e2301162. [PMID: 37821415 DOI: 10.1002/smtd.202301162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 09/26/2023] [Indexed: 10/13/2023]
Abstract
Solid-state lithium batteries (SSLBs) have great development prospects in high-security new energy fields, but face major challenges such as poor charge transfer kinetics, high interface impedance, and unsatisfactory cycle stability. Defect engineering is an effective method to regulate the composition and structure of electrodes and electrolytes, which plays a crucial role in dominating physical and electrochemical performance. It is necessary to summarize the recent advances regarding defect engineering in SSLBs and analyze the mechanism, thus inspiring future work. This review systematically summarizes the role of defects in providing storage sites/active sites, promoting ion diffusion and charge transport of electrodes, and improving structural stability and ionic conductivity of solid-state electrolytes. The defects greatly affect the electronic structure, chemical bond strength and charge transport process of the electrodes and solid-state electrolytes to determine their electrochemical performance and stability. Then, this review presents common defect fabrication methods and the specific role mechanism of defects in electrodes and solid-state electrolytes. At last, challenges and perspectives of defect strategies in high-performance SSLBs are proposed to guide future research.
Collapse
Affiliation(s)
- Jinshuo Mi
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Likun Chen
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Jiabin Ma
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Ke Yang
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Tingzheng Hou
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Ming Liu
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Wei Lv
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Yan-Bing He
- Shenzhen All-Solid-State Lithium Battery Electrolyte Engineering Research Center, Institute of Materials Research (IMR), Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| |
Collapse
|
30
|
Jang S, Kang YS, Kim D, Park S, Seol C, Lee S, Kim SM, Yoo SJ. Multiscale Architectured Membranes, Electrodes, and Transport Layers for Next-Generation Polymer Electrolyte Membrane Fuel Cells. Adv Mater 2023; 35:e2204902. [PMID: 36222387 DOI: 10.1002/adma.202204902] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 08/28/2022] [Indexed: 06/16/2023]
Abstract
Over the past few decades, considerable advances have been achieved in polymer electrolyte membrane fuel cells (PEMFCs) based on the development of material technology. Recently, an emerging multiscale architecturing technology covering nanometer, micrometer, and millimeter scales has been regarded as an alternative strategy to overcome the hindrance to achieving high-performance and reliable PEMFCs. This review summarizes the recent progress in the key components of PEMFCs based on a novel architecture strategy. In the first section, diverse architectural methods for patterning the membrane surface with random, single-scale, and multiscale structures as well as their efficacy for improving catalyst utilization, charge transport, and water management are discussed. In the subsequent section, the electrode structures designed with 1D and 3D multiscale structures to enable low Pt usage, improve oxygen transport, and achieve high electrode durability are elucidated. Finally, recent advances in the architectured transport layer for improving mass transportation including pore gradient, perforation, and patterned wettability for gas diffusion layer and 3D structured/engineered flow fields are described.
Collapse
Affiliation(s)
- Segeun Jang
- School of Mechanical Engineering, Kookmin University, Seoul, 02707, Republic of Korea
| | - Yun Sik Kang
- Fuel Cell Laboratory, Korea Institute of Energy Research (KIER), Daejeon, 34129, Republic of Korea
| | - Dohoon Kim
- School of Mechanical Engineering, Kookmin University, Seoul, 02707, Republic of Korea
| | - Subin Park
- Hydrogen and Fuel Cell Research, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
| | - Changwook Seol
- Department of Mechanical Engineering, Incheon National University, Incheon, 22012, Republic of Korea
| | - Sungchul Lee
- Fuel Cell Core Parts Development Cell, Hyundai Mobis Co. Ltd., Uiwang, 16082, Republic of Korea
| | - Sang Moon Kim
- Department of Mechanical Engineering, Incheon National University, Incheon, 22012, Republic of Korea
| | - Sung Jong Yoo
- Hydrogen and Fuel Cell Research, Korea Institute of Science and Technology (KIST), Seoul, 02792, Republic of Korea
- KHU-KIST Department of Converging Science and Technology, Kyung Hee University, 26, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Republic of Korea
- Division of Energy & Environment Technology, KIST School, University of Science and Technology (UST), Daejeon, 34113, Republic of Korea
| |
Collapse
|
31
|
Wang X, He T, Cheng J, Wu Y, Wang B. Strategies Toward Stretchable Aqueous Zn-based Batteries for Wearable Electronics from Components to Devices. Small Methods 2023; 7:e2300591. [PMID: 37421225 DOI: 10.1002/smtd.202300591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/27/2023] [Indexed: 07/10/2023]
Abstract
Recently, aqueous Zn-based batteries (AZBs) are receiving increased attention in wearable and implantable electronics due to the low cost, high safety, high eco-efficiency, and relatively high energy density. However, it is still a big challenge to develop stretchable AZBs (SAZBs) which can be conformally folded, crumpled, and stretched with human body motions. Although a lot of efforts have been dedicated to constructions of SAZBs, a comprehensive review which focuses on summarizing stretchable materials, device configurations and challenges of SAZBs is needed. Herein, this review attempts to critically review the latest developments and progress in stretchable electrodes, electrolytes, packaging materials and device configurations in detail. Furthermore, these challenges and potential future research directions in the field of SAZBs are also discussed.
Collapse
Affiliation(s)
- Xilin Wang
- Institute of Chemical Materials, China Academy of Engineering Physics, Mianyang, Sichuan, 621900, China
| | - Tao He
- Institute of Chemical Materials, China Academy of Engineering Physics, Mianyang, Sichuan, 621900, China
| | - Jianli Cheng
- Institute of Chemical Materials, China Academy of Engineering Physics, Mianyang, Sichuan, 621900, China
| | - Yuping Wu
- School of Energy and Environment, South East University, Nanjing, Jiangsu, 211189, P. R. China
| | - Bin Wang
- Institute of Fundamental and Frontier Sciences, University of Electronic Sciences and Technology of China, Chengdu, 611731, China
| |
Collapse
|
32
|
Kim J, Han JH, Kim JH. A Study on the O 2 Plasma Etching Method of Spray-Formed SWCNT Films and Their Utilization as Electrodes for Electrochemical Sensors. Sensors (Basel) 2023; 23:7812. [PMID: 37765869 PMCID: PMC10537897 DOI: 10.3390/s23187812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/28/2023] [Accepted: 09/04/2023] [Indexed: 09/29/2023]
Abstract
In this study, we analyzed the morphological changes and molecular structure changes on the surface of single-walled carbon nanotube (SWCNT) films during oxygen plasma (O2) etching of SWCNT surfaces formed by the spray method and analyzed their potential use as electrochemical electrodes. For this purpose, a SWCNT film was formed on the surface of a glass substrate using a self-made spray device using SWCNT powder prepared with DCB as a solvent, and SEM, AFM, and XPS analyses were performed as the SWCNT film was O2 plasma etched. SEM images and AFM measurements showed that the SWCNT film started etching after about 30 s under 50 W of O2 plasma irradiation and was completely etched after about 300 s. XPS analysis showed that as the O2 plasma etching of the SWCNT film progressed, the sp2 bonds representing the basic components of graphite decreased, the sp3 bonds representing defects increased, and the C-O, C=O, and COO peaks increased simultaneously. This result indicates that the SWCNT film was etched by the O2 plasma along with the oxygen species. In addition, electrochemical methods were used to verify the damage potential of the remaining SWCNTs after O2 plasma etching, including cyclic voltammetry, Randles plots, and EIS measurements. This resulted in a reversible response based on perfect diffusion control in the cyclic voltammetry, and an ideal linear curve in the Randles plot of the peak current versus square root scan rate curve. EIS measurements also confirmed that the charge transfer resistance of the remaining SWCNTs after O2 plasma etching is almost the same as before etching. These results indicate that the remaining SWCNTs after O2 plasma etching do not lose their unique electrochemical properties and can be utilized as electrodes for biosensors and electrochemical sensors. Our experimental results also indicate that the ionic conductivity enhancement by O2 plasma can be achieved additionally.
Collapse
Affiliation(s)
- Jinkyeong Kim
- Department of Nanomechatronics Engineering, Pusan University, 2 Busandaehak-ro 63 Beon-gil, Geumjeong-gu, Busan 46241, Republic of Korea
| | - Ji-Hoon Han
- KIURI Center for Hydrogen Based Next Generation Mechanical System, Inha University, Incheon 22212, Republic of Korea
| | - Joon Hyub Kim
- Department of Nanomechatronics Engineering, Pusan University, 2 Busandaehak-ro 63 Beon-gil, Geumjeong-gu, Busan 46241, Republic of Korea
| |
Collapse
|
33
|
Simonenko TL, Simonenko NP, Gorobtsov PY, Simonenko EP, Kuznetsov NT. Current Trends and Promising Electrode Materials in Micro-Supercapacitor Printing. Materials (Basel) 2023; 16:6133. [PMID: 37763411 PMCID: PMC10533130 DOI: 10.3390/ma16186133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/05/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023]
Abstract
The development of scientific and technological foundations for the creation of high-performance energy storage devices is becoming increasingly important due to the rapid development of microelectronics, including flexible and wearable microelectronics. Supercapacitors are indispensable devices for the power supply of systems requiring high power, high charging-discharging rates, cyclic stability, and long service life and a wide range of operating temperatures (from -40 to 70 °C). The use of printing technologies gives an opportunity to move the production of such devices to a new level due to the possibility of the automated formation of micro-supercapacitors (including flexible, stretchable, wearable) with the required type of geometric implementation, to reduce time and labour costs for their creation, and to expand the prospects of their commercialization and widespread use. Within the framework of this review, we have focused on the consideration of the key commonly used supercapacitor electrode materials and highlighted examples of their successful printing in the process of assembling miniature energy storage devices.
Collapse
Affiliation(s)
| | - Nikolay P. Simonenko
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, 119991 Moscow, Russia; (T.L.S.); (P.Y.G.); (E.P.S.); (N.T.K.)
| | | | | | | |
Collapse
|
34
|
de Rijk SR, Boys AJ, Roberts IV, Jiang C, Garcia C, Owens RM, Bance M. Tissue-Engineered Cochlear Fibrosis Model Links Complex Impedance to Fibrosis Formation for Cochlear Implant Patients. Adv Healthc Mater 2023; 12:e2300732. [PMID: 37310792 DOI: 10.1002/adhm.202300732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 05/30/2023] [Indexed: 06/15/2023]
Abstract
Cochlear implants are a life-changing technology for those with severe sensorineural hearing loss, partially restoring hearing through direct electrical stimulation of the auditory nerve. However, they are known to elicit an immune response resulting in fibrotic tissue formation in the cochlea that is linked to residual hearing loss and suboptimal outcomes. Intracochlear fibrosis is difficult to track without postmortem histology, and no specific electrical marker for fibrosis exists. In this study, a tissue-engineered model of cochlear fibrosis is developed following implant placement to examine the electrical characteristics associated with fibrotic tissue formation around electrodes. The model is characterized using electrochemical impedance spectroscopy and an increase in the resistance and a decrease in capacitance of the tissue using a representative circuit are found. This result informs a new marker of fibrosis progression over time that is extractable from voltage waveform responses, which can be directly measured in cochlear implant patients. This marker is tested in a small sample size of recently implanted cochlear implant patients, showing a significant increase over two postoperative timepoints. Using this system, complex impedance is demonstrated as a marker of fibrosis progression that is directly measurable from cochlear implants to enable real-time tracking of fibrosis formation in patients, creating opportunities for earlier treatment intervention to improve cochlear implant efficacy.
Collapse
Affiliation(s)
- Simone R de Rijk
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 3 EB, UK
| | - Alexander J Boys
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS, UK
| | - Iwan V Roberts
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 3 EB, UK
| | - Chen Jiang
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 3 EB, UK
- Department of Electronic Engineering, Tsinghua University, Beijing, 100190, P. R. China
| | - Charlotte Garcia
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| | - Róisín M Owens
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge, CB2 8AF, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 3 EB, UK
| |
Collapse
|
35
|
Mehregan M, Stalla D, Luebbert G, Baratta L, Brathwaite KG, Wyatt QK, Paranamana NC, Young MJ. Compressible sponge electrodes by oxidative molecular layer deposition (oMLD) of polyethylenedioxythiophene (PEDOT) onto open-cell polyurethane sponges. Nanotechnology 2023; 34. [PMID: 37567164 DOI: 10.1088/1361-6528/acef2b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 08/10/2023] [Indexed: 08/13/2023]
Abstract
The formation of compressible porous sponge electrodes is appealing to overcome diffusion limitations in porous electrodes for applications including electrochemical energy storage, electrochemical water desalination, and electrocatalysis. Previous work has employed wet chemical synthesis to deliver conductive materials into porous polymer sponge supports, but these approaches struggle to produce functional electrodes due to (1) poor electrical connectivity of the conductive network and (2) mechanical rigidity of the foam after coating. In this work we employ oxidative molecular layer deposition (oMLD) via sequential gas-phase exposures of 3,4 ethylenedioxythiophene (EDOT) and molybdenum pentachloride (MoCl5) oxidant to imbibe polyurethane (PU) sponges with electrically-conductive and redox-active poly(3,4 ethylenedioxythiophene) (PEDOT) coatings. We analyze the oMLD deposition on compressive PU sponges and modify the reaction conditions to obtain mechanically compressible and electrically conductive sponge electrodes. We specifically identify the importance MoCl5dose time to enhance the conductivity of the sponges and the importance of EDOT purge time to preserve the mechanical properties of the sponges. Controlling these variables produces an electrically conductive PEDOT network within the sponge support with reduced impact on the sponge's mechanical properties, offering advantages over wet-chemical synthesis approaches. The compressible, conductive sponges we generate have the potential to be used as compressible electrodes for water desalination, energy storage, and electrocatalysis.
Collapse
Affiliation(s)
- Mahya Mehregan
- Department of Chemistry, University of Missouri, Columbia, MO, United States of America
| | - David Stalla
- Electron Microscopy Core, University of Missouri, Columbia, MO, United States of America
| | - Gabe Luebbert
- Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, MO, United States of America
| | - Lauren Baratta
- Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, MO, United States of America
| | - Katrina G Brathwaite
- Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, MO, United States of America
| | - Quinton K Wyatt
- Department of Chemistry, University of Missouri, Columbia, MO, United States of America
| | - Nikhila C Paranamana
- Department of Chemistry, University of Missouri, Columbia, MO, United States of America
| | - Matthias J Young
- Department of Chemistry, University of Missouri, Columbia, MO, United States of America
- Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, MO, United States of America
- Materials Science and Engineering Institute, University of Missouri, Columbia, MO, United States of America
| |
Collapse
|
36
|
Nigam R, Kar KK. Effect of simple cubic, face-centered cubic, and body-centered cubic- electrodes on the electric double layer capacitance of supercapacitors. Nanotechnology 2023; 34. [PMID: 37582342 DOI: 10.1088/1361-6528/acf04d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Accepted: 08/14/2023] [Indexed: 08/17/2023]
Abstract
The continuum theory has been used to analyze the polarization, ion crowding, and electrostatic forces of the electric double layer in the electrode materials having simple cubic (SC), body-centered cubic (BCC), and face-centered cubic (FCC) morphologies. The study manifests the effect of thickness of electrodes, electrode's particle size, and porosity on electric double-layer specific capacitance (EDLC). Electrochemical interference and the specific capacitance depend on the packing factor. The larger particle size decreases the specific capacitance, but porosity increases due to more surface area. Due to symmetry, SC, BCC, and FCC morphologies have 1, 3, and 5 spheres in a unit cell. The number of unit cells is varied from 1 to 100 in model 1 to analyze the effect of electrode thickness. Model 2 has three unit cells to understand the effect of porosity, and only pore lengths are varied. The critical thickness of the electrodes is the integer multiples of 1.71μm in all the morphologies. The Stern layer-specific capacitance is 167.6μF cm-2in all cases. The EDLC in BCC is around 5.6-7.6μF cm-2in the steady state that is intermediate between SC and FCC morphologies. The more dense packing of carbon particles in a unit cell increases the energy storage capabilities of electrodes. The average electrode permittivity slightly decreases due to the combined effect of the high electric field, status of polarization, and electrode particle size. The least optical transmission of electrodes is 98.35%.
Collapse
Affiliation(s)
- Ravi Nigam
- Advanced Nanoengineering Materials Laboratory, Materials Science Programme, Indian Institute of Technology Kanpur, Kanpur-208016, India
| | - Kamal K Kar
- Advanced Nanoengineering Materials Laboratory, Materials Science Programme, Indian Institute of Technology Kanpur, Kanpur-208016, India
- Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur-208016, India
| |
Collapse
|
37
|
Abstract
Electroencephalogram (EEG) records the electrical activity of neurons in the cerebral cortex and is used extensively to diagnose, treat, and monitor psychiatric and neurological conditions. Reliable contact between the skin and the electrodes is essential for achieving consistency and for obtaining electroencephalographic information. There has been an increasing demand for effective equipment and electrodes to overcome the time-consuming and cumbersome application of traditional systems. Recently, ear-centered EEG has met with growing interest since it can provide good signal quality due to the proximity of the ear to the brain. In addition, it can facilitate mobile and unobtrusive usage due to its smaller size and ease of use, since it can be used without interfering with the patient's daily activities. The purpose of this mini-review is to first introduce the broad range of electrodes used in conventional (scalp) EEG and subsequently discuss the state-of-the-art literature about around- and in-the-ear EEG.
Collapse
Affiliation(s)
- Gayaneh Petrossian
- Department of Chemical Engineering, Polytechnique Montréal, Montréal, Québec H3C 3A7, Canada
| | - Pierre Kateb
- Department of Chemical Engineering, Polytechnique Montréal, Montréal, Québec H3C 3A7, Canada
| | | | - Fabio Cicoira
- Department of Chemical Engineering, Polytechnique Montréal, Montréal, Québec H3C 3A7, Canada
| |
Collapse
|
38
|
Quansah Amissah R, Albeely AM, Bragg EM, Perreault ML, Doucette WT, Khokhar JY. A Simple, Lightweight, and Low-Cost Customizable Multielectrode Array for Local Field Potential Recordings. eNeuro 2023; 10:ENEURO.0212-23.2023. [PMID: 37643859 PMCID: PMC10467017 DOI: 10.1523/eneuro.0212-23.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/01/2023] [Accepted: 08/03/2023] [Indexed: 08/31/2023] Open
Abstract
Local field potential (LFP) recording is a valuable method for assessing brain systems communication. Multiple methods have been developed to collect LFP data to study the rhythmic activity of the brain. These methods range from the use of single or bundled metal electrodes to electrode arrays that can target multiple brain regions. Although these electrodes are efficient in collecting LFP activity, they can be expensive, difficult to build, and less adaptable to different applications, which may include targeting multiple brain regions simultaneously. Here, the building process for a 16-channel customizable multielectrode array (CMEA) that can be used to collect LFP data from different brain regions simultaneously in rats is described. These CMEA electrode arrays are lightweight (<1 g), take little time to build (<1 h), and are affordable ($15 Canadian). The CMEA can also be modified to record single-unit and multiunit activity in addition to LFP activity using both wired and wireless neural data acquisition systems. Moreover, these CMEAs can be used to explore neural activity (LFP and single-unit/multiunit activity) in preliminary studies, before purchasing more expensive electrodes for targeted studies. Together, these characteristics make the described CMEA a competitive alternative to the commercially available multielectrode arrays for its simplicity, low cost, and efficiency in collecting LFP data in freely behaving animals.
Collapse
Affiliation(s)
- Richard Quansah Amissah
- Department of Biomedical Sciences, Ontario Veterinary College, University of Guelph, Guelph, Ontario N1G 2W1, Canada
| | - Abdalla M Albeely
- Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, Ontario N6A 5C1, Canada
| | - Elise M Bragg
- Department of Psychiatry, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire 03756
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire 03755-1404
| | - Melissa L Perreault
- Department of Biomedical Sciences, Ontario Veterinary College, University of Guelph, Guelph, Ontario N1G 2W1, Canada
| | - Wilder T Doucette
- Department of Psychiatry, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire 03756
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire 03755-1404
| | - Jibran Y Khokhar
- Department of Biomedical Sciences, Ontario Veterinary College, University of Guelph, Guelph, Ontario N1G 2W1, Canada
- Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, Ontario N6A 5C1, Canada
| |
Collapse
|
39
|
Fonseca N, Thummalapalli SV, Jambhulkar S, Ravichandran D, Zhu Y, Patil D, Thippanna V, Ramanathan A, Xu W, Guo S, Ko H, Fagade M, Kannan AM, Nian Q, Asadi A, Miquelard-Garnier G, Dmochowska A, Hassan MK, Al-Ejji M, El-Dessouky HM, Stan F, Song K. 3D Printing-Enabled Design and Manufacturing Strategies for Batteries: A Review. Small 2023:e2302718. [PMID: 37501325 DOI: 10.1002/smll.202302718] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 07/08/2023] [Indexed: 07/29/2023]
Abstract
Lithium-ion batteries (LIBs) have significantly impacted the daily lives, finding broad applications in various industries such as consumer electronics, electric vehicles, medical devices, aerospace, and power tools. However, they still face issues (i.e., safety due to dendrite propagation, manufacturing cost, random porosities, and basic & planar geometries) that hinder their widespread applications as the demand for LIBs rapidly increases in all sectors due to their high energy and power density values compared to other batteries. Additive manufacturing (AM) is a promising technique for creating precise and programmable structures in energy storage devices. This review first summarizes light, filament, powder, and jetting-based 3D printing methods with the status on current trends and limitations for each AM technology. The paper also delves into 3D printing-enabled electrodes (both anodes and cathodes) and solid-state electrolytes for LIBs, emphasizing the current state-of-the-art materials, manufacturing methods, and properties/performance. Additionally, the current challenges in the AM for electrochemical energy storage (EES) applications, including limited materials, low processing precision, codesign/comanufacturing concepts for complete battery printing, machine learning (ML)/artificial intelligence (AI) for processing optimization and data analysis, environmental risks, and the potential of 4D printing in advanced battery applications, are also presented.
Collapse
Affiliation(s)
- Nathan Fonseca
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Sri Vaishnavi Thummalapalli
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Sayli Jambhulkar
- Systems Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Dharneedar Ravichandran
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Yuxiang Zhu
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Dhanush Patil
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Varunkumar Thippanna
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Arunachalam Ramanathan
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Weiheng Xu
- Systems Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Shenghan Guo
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
- Systems Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Hyunwoong Ko
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
- Systems Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
| | - Mofe Fagade
- Mechanical Engineering, School of Engineering for Matter, Transport and Energy (SEMTE), Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, AZ, 85281, USA
| | - Arunchala M Kannan
- Fuel Cell Laboratory, The Polytechnic School (TPS), Ira A. Fulton Schools of Engineering, Arizona State University, Mesa, AZ, 85212, USA
| | - Qiong Nian
- School of Engineering for Matter, Transport and Energy (SEMTE), Arizona State University, Tempe, AZ, 85287, USA
| | - Amir Asadi
- Department of Engineering Technology and Industrial Distribution (ETID), Texas A&M University, College Station, TX, 77843, USA
| | - Guillaume Miquelard-Garnier
- Laboratoire PIMM, Arts et Métiers Institute of Technology, CNRS, Cnam, HESAM Universite, 151 Boulevard de l'Hopital, Paris, 75013, France
| | - Anna Dmochowska
- Laboratoire PIMM, Arts et Métiers Institute of Technology, CNRS, Cnam, HESAM Universite, 151 Boulevard de l'Hopital, Paris, 75013, France
| | - Mohammad K Hassan
- Center for Advanced Materials, Qatar University, P.O. BOX 2713, Doha, Qatar
| | - Maryam Al-Ejji
- Center for Advanced Materials, Qatar University, P.O. BOX 2713, Doha, Qatar
| | - Hassan M El-Dessouky
- Physics Department, Faculty of Science, Galala University, Galala City, 43511, Egypt
- Physics Department, Faculty of Science, Mansoura University, Mansoura, 35516, Egypt
| | - Felicia Stan
- Center of Excellence Polymer Processing & Faculty of Engineering, Dunarea de Jos University of Galati, 47 Domneasca Street, Galati, 800008, Romania
| | - Kenan Song
- Manufacturing Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
- Systems Engineering, School of Manufacturing Systems and Networks (MSN), Ira A. Fulton Schools of Engineering, Arizona State University (ASU), Mesa, AZ, 85212, USA
- Mechanical Engineering, University of Georgia, 302 E. Campus Rd, Athens, Georgia, 30602, United States
| |
Collapse
|
40
|
Ishii A, Nemoto N, Yamaguchi M, Kobayashi K, Oikawa I, Takano A, Hitomi T, Hayashi N, Takamura H. Key Role of Interfacial Cobalt Segregation in Stable Low-Resistance Composite Oxygen-Reducing Electrodes. ACS Appl Mater Interfaces 2023. [PMID: 37435978 DOI: 10.1021/acsami.3c04940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 07/13/2023]
Abstract
The development of efficient and stable oxygen-reducing electrodes is challenging but vital for the production of efficient electrochemical cells. Composite electrodes composed of mixed ionic-electronic conducting La1-xSrxCo1-yFeyO3-δ and ionic conducting doped CeO2 are considered promising components for solid oxide fuel cells. However, no consensus has been reached regarding the reasons of the good electrode performance, and inconsistent performance has been reported among various research groups. To mitigate the difficulties related to analyzing composite electrodes, this study applied three-terminal cathodic polarization to dense and nanoscale La0.6Sr0.4CoO3-δ-Ce0.8Sm0.2O1.9 (LSC-SDC) model electrodes. The critical factors determining the performance of the composite electrodes are the segregation of catalytic cobalt oxides to the electrolyte interfaces and the oxide-ion conducting paths provided by SDC. The addition of Co3O4 to the LSC-SDC electrode resulted in reduced LSC decomposition; thus, the interfacial and electrode resistances were low and stable. In the Co3O4-added LSC-SDC electrode under cathodic polarization, Co3O4 turned wurtzite-type CoO, which suggested that the Co3O4 addition suppressed the decomposition of LSC and, thus, the cathodic bias was maintained from the electrode surface to electrode-electrolyte interface. This study shows that cobalt oxide segregation behavior must be considered when discussing the performance of composite electrodes. Furthermore, by controlling the segregation process, microstructure, and phase evolution, stable low-resistance composite oxygen-reducing electrodes can be fabricated.
Collapse
Affiliation(s)
- Akihiro Ishii
- Department of Materials Science, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Natsumi Nemoto
- Department of Materials Science, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Mina Yamaguchi
- Department of Materials Science, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Kosei Kobayashi
- Technical Division, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Itaru Oikawa
- Department of Materials Science, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| | - Akira Takano
- Environment Neutral Systems Development Division, DENSO Corporation, Kariya 448-8661, Aichi, Japan
| | - Takuma Hitomi
- Environment Neutral Systems Development Division, DENSO Corporation, Kariya 448-8661, Aichi, Japan
| | - Naohiro Hayashi
- Environment Neutral Systems Development Division, DENSO Corporation, Kariya 448-8661, Aichi, Japan
| | - Hitoshi Takamura
- Department of Materials Science, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
| |
Collapse
|
41
|
Liu Q, Yu Z, Zhang B. Tackling the Challenges of Aqueous Zn-Ion Batteries via Polymer-Derived Strategies. Small Methods 2023:e2300255. [PMID: 37417207 DOI: 10.1002/smtd.202300255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/30/2023] [Indexed: 07/08/2023]
Abstract
Zn-ion batteries (ZIBs) have gathered unprecedented interest recently benefiting from their intrinsic safety, affordability, and environmental benignity. Nevertheless, their practical implementation is hampered by low rate performance, inferior Zn2+ diffusion kinetics, and undesired parasitic reactions. Innovative solutions are put forth to address these issues by optimizing the electrodes, separators, electrolytes, and interfaces. Remarkably, polymers with inherent properties of low-density, high processability, structural flexibility, and superior stability show great promising in tackling the challenges. Herein, the recent progress in the synthesis and customization of functional polymers in aqueous ZIBs is outlined. The recent implementations of polymers into each component are summarized, with a focus on the inherent mechanisms underlying their unique functions. The challenges of incorporating polymers into practical ZIBs are also discussed and possible solutions to circumvent them are proposed. It is hoped that such a deep analysis could accelerate the design of polymer-derived approaches to boost the performance of ZIBs and other aqueous battery systems as they share similarities in many aspects.
Collapse
Affiliation(s)
- Qun Liu
- Department of Applied Physics and Research Institute for Smart Energy, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, 999077, China
| | - Zhenlu Yu
- Department of Applied Physics and Research Institute for Smart Energy, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, 999077, China
| | - Biao Zhang
- Department of Applied Physics and Research Institute for Smart Energy, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, 999077, China
| |
Collapse
|
42
|
Oeur A, Torp WH, Arbogast KB, Master CL, Margulies SS. Altered Auditory and Visual Evoked Potentials following Single and Repeated Low-Velocity Head Rotations in 4-Week-Old Swine. Biomedicines 2023; 11:1816. [PMID: 37509456 PMCID: PMC10376588 DOI: 10.3390/biomedicines11071816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/22/2023] [Accepted: 06/22/2023] [Indexed: 07/30/2023] Open
Abstract
Auditory and visually evoked potentials (EP) have the ability to monitor cognitive changes after concussion. In the literature, decreases in EP are commonly reported; however, a subset of studies shows increased cortical activity after injury. We studied auditory and visual EP in 4-week-old female Yorkshire piglets (N = 35) divided into anesthetized sham, and animals subject to single (sRNR) and repeated (rRNR) rapid non-impact head rotations (RNR) in the sagittal direction. Two-tone auditory oddball tasks and a simple white-light visual stimulus were evaluated in piglets pre-injury, and at days 1, 4- and 7 post injury using a 32-electrode net. Traditional EP indices (N1, P2 amplitudes and latencies) were extracted, and a piglet model was used to source-localize the data to estimate brain regions related to auditory and visual processing. In comparison to each group's pre-injury baselines, auditory Eps and brain activity (but not visual activity) were decreased in sham. In contrast, sRNR had increases in N1 and P2 amplitudes from both stimuli. The rRNR group had decreased visual N1 amplitudes but faster visual P2 latencies. Auditory and visual EPs have different change trajectories after sRNR and rRNR, suggesting that injury biomechanics are an important factor to delineate neurofunctional deficits after concussion.
Collapse
Affiliation(s)
- Anna Oeur
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA 30332, USA; (A.O.); (W.H.T.)
| | - William H. Torp
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA 30332, USA; (A.O.); (W.H.T.)
| | - Kristy B. Arbogast
- Center for Injury Research and Prevention, Children’s Hospital of Philadelphia, Philadelphia, PA 19146, USA; (K.B.A.); (C.L.M.)
- Perelman School of Medicine, the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Christina L. Master
- Center for Injury Research and Prevention, Children’s Hospital of Philadelphia, Philadelphia, PA 19146, USA; (K.B.A.); (C.L.M.)
- Perelman School of Medicine, the University of Pennsylvania, Philadelphia, PA 19104, USA
- Sports Medicine and Performance Center, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA
| | - Susan S. Margulies
- Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA 30332, USA; (A.O.); (W.H.T.)
| |
Collapse
|
43
|
Malozyomov BV, Kukartsev VV, Martyushev NV, Kondratiev VV, Klyuev RV, Karlina AI. Improvement of Hybrid Electrode Material Synthesis for Energy Accumulators Based on Carbon Nanotubes and Porous Structures. Micromachines (Basel) 2023; 14:1288. [PMID: 37512599 PMCID: PMC10385283 DOI: 10.3390/mi14071288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/19/2023] [Accepted: 06/21/2023] [Indexed: 07/30/2023]
Abstract
Carbon materials are promising for use as electrodes for supercapacitors and lithium-ion batteries due to a number of properties, such as non-toxicity, high specific surface area, good electronic conductivity, chemical inertness, and a wide operating temperature range. Carbon-based electrodes, with their characteristic high specific power and good cyclic stability, can be used for a new generation of consumer electronics, biomedical devices and hybrid electric vehicles. However, most carbon materials, due to their low electrical conductivity and insufficient diffusion of electrolyte ions in complex micropores, have energy density limitations in these devices due to insufficient number of pores for electrolyte diffusion. This work focuses on the optimization of a hybrid material based on porous carbon and carbon nanotubes by mechanical mixing. The purpose of this work is to gain new knowledge about the effect of hybrid material composition on its specific capacitance. The material for the study is taken on the basis of porous carbon and carbon nanotubes. Electrodes made of this hybrid material were taken as an object of research. Porous carbon or nitrogen-containing porous carbon (combined with single-, double-, or multi-layer carbon nanotubes (single-layer carbon nanotubes, bilayer carbon nanotubes or multilayer carbon nanotubes) were used to create the hybrid material. The effect of catalytic chemical vapor deposition synthesis parameters, such as flow rate and methane-to-hydrogen ratio, as well as the type of catalytic system on the multilayer carbon nanotubes structure was investigated. Two types of catalysts based on Mo12O28 (μ2-OH)12{Co(H2O)3}4 were prepared for the synthesis of multilayer carbon nanotubes by precipitation and combustion. The resulting carbon materials were tested as electrodes for supercapacitors and lithium ion intercalation. Electrodes based on nitrogen-containing porous carbon/carbon nanotubes 95:5% were found to be the most efficient compared to nitrogen-doped porous carbon by 10%. Carbon nanotubes, bilayer carbon nanotubes and multilayer carbon nanotubes synthesized using the catalyst obtained by deposition were selected as additives for the hybrid material. The hybrid materials were obtained by mechanical mixing and dispersion in an aqueous solution followed by lyophilization to remove water. When optimizing the ratio of the hybrid material components, the most effective porous carbon:carbon nanotubes component ratio was determined.
Collapse
Affiliation(s)
- Boris V Malozyomov
- Department of Electrotechnical Complexes, Novosibirsk State Technical University, 630073 Novosibirsk, Russia
| | - Vladislav V Kukartsev
- Department of Informatics, Institute of Space and Information Technologies, Siberian Federal University, 660041 Krasnoyarsk, Russia
- Department of Information Economic Systems, Institute of Engineering and Economics, Reshetnev Siberian State University of Science and Technology, 660037 Krasnoyarsk, Russia
- Digital Material Science: New Materials and Technologies, Bauman Moscow State Technical University, 105005 Moscow, Russia
| | - Nikita V Martyushev
- Scientific Department, Kh. Ibragimov Complex Institute of the Russian Academy of Sciences, 364906 Grozny, Russia
| | - Viktor V Kondratiev
- Laboratory of Geochemistry of Ore Formation and Geochemical Methods of Prospecting, A. P. Vinogradov Institute of Geochemistry of the Siberian Branch of the Russian Academy of Sciences, 664033 Irkutsk, Russia
| | - Roman V Klyuev
- Technique and Technology of Mining and Oil and Gas Production Department, Moscow Polytechnic University, 107023 Moscow, Russia
| | - Antonina I Karlina
- Stroytest Research and Testing Center, Moscow State University of Civil Engineering, 129337 Moscow, Russia
| |
Collapse
|
44
|
Nandedkar SD, Barkhaus PE. Recording sensory nerve action potential using different electrode types. Muscle Nerve 2023. [PMID: 37300406 DOI: 10.1002/mus.27916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 05/15/2023] [Accepted: 05/20/2023] [Indexed: 06/12/2023]
Abstract
INTRODUCTION/AIMS Switching between different types of electrodes during motor and sensory nerve conduction studies adds time to a study. We investigated the use of disposable disc electrodes (DDE) used for motor nerve conduction studies to record the antidromic sensory nerve action potential (SNAP) in median, ulnar and radial sensory nerve conduction studies. METHODS The SNAP was recorded using four different electrode types: reusable ring, reusable bar, disposable ring, and DDE in a random rotating order. Studies were performed in healthy subjects. Other than being an adult with no history of neuromuscular disease, there were no exclusion criteria. RESULTS We studied 20 subjects (11 females, 9 males; age 41.1 ± 15.7 y). The SNAP waveforms recorded by all four electrode types were similar. There was no statistically significant difference in the onset latency, peak latency (PL), negative peak amplitude (NPA), peak to peak amplitude, or conduction velocity. In individual nerve recordings, the absolute PL difference between reusable ring electrodes (our current standard) and DDE was less than 0.2 ms in 58 of 60 (97%) nerves. The mean absolute NPA difference was 3.1 μV (standard deviation = 2.85 μV). Recordings with NPA difference >5 μV also had high NPA and/or had large artifacts. DISCUSSION DDE may be used for performing motor and sensory nerve conduction studies. This can reduce the time required for electrodiagnostic testing.
Collapse
Affiliation(s)
- Sanjeev D Nandedkar
- Natus Medical Inc, Middleton, Wisconsin, USA
- Departments of Neurology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Paul E Barkhaus
- Departments of Neurology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| |
Collapse
|
45
|
Shi Y, Yang F, Tao L. Ni-Activated and Ni-P-Activated Porous Titanium Carbide Ceramic Electrodes as Efficient Electrocatalysts for Overall Water Splitting. ACS Appl Mater Interfaces 2023. [PMID: 37276586 DOI: 10.1021/acsami.3c03398] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Developing electrocatalysts based on transition-metal carbides that can be utilized for commercial water splitting is a challenging endeavor. To address this challenge, we employed a novel approach that merged phase-inversion tape-casting and sintering, subsequently implementing a simple and efficient electrodeposition process, to synthesize Ni-activated and Ni-P-activated titanium carbide (Ni/TiC, Ni-P/TiC) ceramic electrodes as water splitting catalytic cathodes and anodes. These self-supported Ni/TiC and Ni-P/TiC electrodes are binder-free with abundant finger-like pores, which contribute to the formation of highly conductive skeleton and more exposed active sites for direct water splitting. These catalysts exhibit outstanding performance, superior to many reported bifunctional nickel-based catalysts supported on other substrates. Moreover, the exceptional electrocatalytic performance of the Ni/TiC and Ni-P/TiC catalysts is attributed to the synergistic effect between Ni oxides (phosphides) and TiC, as revealed by density functional theory (DFT) calculations. This self-template strategy paves the way for fabricating industrially applicable electrodes to generate hydrogen and oxygen through water splitting.
Collapse
Affiliation(s)
- Yangyang Shi
- School of Materials Science and Engineering, Jiangsu Key Laboratory of Advanced Metallic Materials, Southeast University, Nanjing 211189, China
| | - Fengyi Yang
- Hefei National Research Center of Physical Sciences at the Microscale & Department of Chemistry, University of Science and Technology of China, Hefei 230026, China
| | - Li Tao
- School of Materials Science and Engineering, Jiangsu Key Laboratory of Advanced Metallic Materials, Southeast University, Nanjing 211189, China
| |
Collapse
|
46
|
Pan Z, Yu S, Wang L, Li C, Meng F, Wang N, Zhou S, Xiong Y, Wang Z, Wu Y, Liu X, Fang B, Zhang Y. Recent Advances in Porous Carbon Materials as Electrodes for Supercapacitors. Nanomaterials (Basel) 2023; 13:nano13111744. [PMID: 37299646 DOI: 10.3390/nano13111744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 05/13/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023]
Abstract
Porous carbon materials have demonstrated exceptional performance in various energy and environment-related applications. Recently, research on supercapacitors has been steadily increasing, and porous carbon materials have emerged as the most significant electrode material for supercapacitors. Nonetheless, the high cost and potential for environmental pollution associated with the preparation process of porous carbon materials remain significant issues. This paper presents an overview of common methods for preparing porous carbon materials, including the carbon-activation method, hard-templating method, soft-templating method, sacrificial-templating method, and self-templating method. Additionally, we also review several emerging methods for the preparation of porous carbon materials, such as copolymer pyrolysis, carbohydrate self-activation, and laser scribing. We then categorise porous carbons based on their pore sizes and the presence or absence of heteroatom doping. Finally, we provide an overview of recent applications of porous carbon materials as electrodes for supercapacitors.
Collapse
Affiliation(s)
- Zhengdao Pan
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Sheng Yu
- Department of Chemistry, Washington State University, Pullman, Washington, DC 99164, USA
| | - Linfang Wang
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Chenyu Li
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Fei Meng
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Nan Wang
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Shouxin Zhou
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Ye Xiong
- Kucap Smart Technology (Nanjing) Co., Ltd., Nanjing 211106, China
| | - Zhoulu Wang
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Yutong Wu
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Xiang Liu
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Baizeng Fang
- Department of Energy Storage Science and Technology, University of Science and Technology Beijing, 30 College Road, Beijing 100083, China
| | - Yi Zhang
- School of Energy Sciences and Engineering, Nanjing Tech University, Nanjing 211816, China
| |
Collapse
|
47
|
Kojima A, Yoshimoto S, Yamamoto A. Optimization of electrode positions for equalizing local spatial performance of a tomographic tactile sensor. Front Robot AI 2023; 10:1157911. [PMID: 37265743 PMCID: PMC10229801 DOI: 10.3389/frobt.2023.1157911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 05/05/2023] [Indexed: 06/03/2023] Open
Abstract
A tomographic tactile sensor based on the contact resistance of conductors is a high sensitive pressure distribution imaging method and has advantages on the flexibility and scalability of device. While the addition of internal electrodes improves the sensor's spatial resolution, there still remain variations in resolution that depend on the contact position. In this study, we propose an optimization algorithm for electrode positions that improves entire spatial resolution by compensating for local variations in spatial resolution. Simulation results for sensors with 16 or 64 electrodes show that the proposed algorithm improves performance to 0.81 times and 0.93 times in the worst spatial resolution region of the detection area compared to equally spaced grid electrodes. The proposed methods enable tomographic tactile sensors to detect contact pressure distribution more accurately than the conventional methods, providing high-performance tactile sensing for many applications.
Collapse
|
48
|
Jia M, Wang M, Zhou Y. A Flexible and Highly Sensitive Pressure Sense Electrode Based on Cotton Pulp for Wearable Electronics. Polymers (Basel) 2023; 15:polym15092095. [PMID: 37177243 PMCID: PMC10181469 DOI: 10.3390/polym15092095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/25/2023] [Accepted: 04/25/2023] [Indexed: 05/15/2023] Open
Abstract
Flexible pressure sensors with high sensitivity have great potential applications in wearable electronics. However, it is still a great challenge to prepare sense electrodes with high flexibility, high sensitivity, and high electrochemical performance. Here, we propose a novel and simple method for carbonizing cotton fibers as excellent electrically conductive materials. Moreover, carbonized cotton fiber (CCF) and polydimethylsiloxane (PDMS) were assembled into a flexible sense electrode. The CCF/PDMS electrode shows a high sensitivity of 10.8 kPa-1, a wide response frequency from 0.2-2.0 Hz, and durability over 900 cycles. The combined CCF/PDMS sensors can monitor human movement and pulse vibration, showing the enormous potential for use in wearable device technology. Additionally, the CCF/PDMS can be used as electrodes with a specific capacitance of 332.5 mF cm-2 at a current density of 5 mA cm-2, thanks to their high electrical conductivity and hydrophilicity, demonstrating the promising prospect of flexible supercapacitors.
Collapse
Affiliation(s)
- Mengying Jia
- School of Information and Electrical Engineering, Shandong Jianzhu University, Jinan 250101, China
| | - Meng Wang
- National Supercomputer Research Center of Advanced Materials, Advanced Materials Institute, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250014, China
| | - Yucheng Zhou
- School of Information and Electrical Engineering, Shandong Jianzhu University, Jinan 250101, China
| |
Collapse
|
49
|
Mohamed MA, Arnold S, Janka O, Quade A, Presser V, Kickelbick G. Self-Activation of Inorganic-Organic Hybrids Derived through Continuous Synthesis of Polyoxomolybdate and para-Phenylenediamine Enables Very High Lithium-Ion Storage Capacity. ChemSusChem 2023; 16:e202202213. [PMID: 36542465 DOI: 10.1002/cssc.202202213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/16/2022] [Indexed: 06/17/2023]
Abstract
Inorganic-organic hybrid materials with redox-active components were prepared by an aqueous precipitation reaction of ammonium heptamolybdate (AHM) with para-phenylenediamine (PPD). A scalable and low-energy continuous wet chemical synthesis process, known as the microjet process, was used to prepare particles with large surface area in the submicrometer range with high purity and reproducibility on a large scale. Two different crystalline hybrid products were formed depending on the ratio of molybdate to organic ligand and pH. A ratio of para-phenylenediamine to ammonium heptamolybdate from 1 : 1 to 5 : 1 resulted in the compound [C6 H10 N2 ]2 [Mo8 O26 ] ⋅ 6 H2 O, while higher PPD ratios from 9 : 1 to 30 : 1 yielded a composition of [C6 H9 N2 ]4 [NH4 ]2 [Mo7 O24 ] ⋅ 3 H2 O. The electrochemical behavior of the two products was tested in a battery cell environment. Only the second of the two hybrid materials showed an exceptionally high capacity of 1084 mAh g-1 at 100 mA g-1 after 150 cycles. The maximum capacity was reached after an induction phase, which can be explained by a combination of a conversion reaction with lithium to Li2 MoO4 and an additional in situ polymerization of PPD. The final hybrid material is a promising material for lithium-ion battery (LIB) applications.
Collapse
Affiliation(s)
- Mana Abdirahman Mohamed
- Inorganic Solid-State Chemistry, Saarland University, Campus C4 1, 66123, Saarbrücken, Germany
| | - Stefanie Arnold
- INM-Leibniz Institute for New Materials, 66123, Saarbrücken, Germany
- Department of Materials Science and Engineering, Saarland University, 66123, Saarbrücken, Germany
| | - Oliver Janka
- Inorganic Solid-State Chemistry, Saarland University, Campus C4 1, 66123, Saarbrücken, Germany
| | - Antje Quade
- Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Straße 2, 17489, Greifswald, Germany
| | - Volker Presser
- INM-Leibniz Institute for New Materials, 66123, Saarbrücken, Germany
- Department of Materials Science and Engineering, Saarland University, 66123, Saarbrücken, Germany
- Saarene-Saarland Center for Energy Materials and Sustainability, 66123, Saarbrücken, Germany
| | - Guido Kickelbick
- Inorganic Solid-State Chemistry, Saarland University, Campus C4 1, 66123, Saarbrücken, Germany
| |
Collapse
|
50
|
Tooley M. Electronics and biological signal processing. BJA Educ 2023; 23:122-127. [PMID: 36960437 PMCID: PMC10028393 DOI: 10.1016/j.bjae.2022.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/06/2022] [Indexed: 02/11/2023] Open
Affiliation(s)
- M.A. Tooley
- University of Bath, Bath, UK
- Royal United Hospitals, Bath, UK
| |
Collapse
|