• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4591707)   Today's Articles (1619)   Subscriber (49315)
For: Barros SE, Vanz V, Chiqueto K, Janson G, Ferreira E. Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: an experimental laboratory study. Prog Orthod 2021;22:9. [PMID: 33748887 PMCID: PMC7982375 DOI: 10.1186/s40510-021-00352-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 02/19/2021] [Indexed: 11/10/2022]  Open
Number Cited by Other Article(s)
1
Insertion torque, flexural strength and surface alterations of stainless steel and titanium alloy orthodontic mini-implants: an in vitro study. Dental Press J Orthod 2024;29:e2423282. [PMID: 38775601 PMCID: PMC11104944 DOI: 10.1590/2177-6709.29.2.e2423282.oar] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 03/04/2024] [Indexed: 05/25/2024]  Open
2
Titanium Alloy Implants with Lattice Structures for Mandibular Reconstruction. MATERIALS (BASEL, SWITZERLAND) 2023;17:140. [PMID: 38203994 PMCID: PMC10779528 DOI: 10.3390/ma17010140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 11/30/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024]
3
The effect of different orthodontic mini-implant brands and geometry on primary stability (an in vitro study). Heliyon 2023;9:e19858. [PMID: 37809894 PMCID: PMC10559246 DOI: 10.1016/j.heliyon.2023.e19858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 08/29/2023] [Accepted: 09/04/2023] [Indexed: 10/10/2023]  Open
4
Stress distribution for mandibular extra-alveolar anchorage at different angles and force magnitudes: a finite element study. Comput Methods Biomech Biomed Engin 2023:1-9. [PMID: 37647253 DOI: 10.1080/10255842.2023.2252549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 06/16/2023] [Accepted: 08/17/2023] [Indexed: 09/01/2023]
5
Biomimetic calcium phosphate coating on medical grade stainless steel improves surface properties and serves as a drug carrier for orthodontic applications. Dent Mater 2023;39:152-161. [PMID: 36610898 DOI: 10.1016/j.dental.2022.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 12/05/2022] [Accepted: 12/24/2022] [Indexed: 01/07/2023]
6
Evidence-based selection of orthodontic miniscrews, increasing their success rate in the mandibular buccal shelf. A randomized, prospective clinical trial. BMC Oral Health 2022;22:414. [PMID: 36127718 PMCID: PMC9487090 DOI: 10.1186/s12903-022-02460-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Accepted: 09/14/2022] [Indexed: 12/03/2022]  Open
7
Maxillary Skeletal Expansion with Monocortical and Bicortical Miniscrew Anchorage: A 3D Finite Element Study. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
8
A case report on a IV-degree thermal crush injury of right upper arm:The application of functional prosthesis implantation technology. J Burn Care Res 2021;43:487-491. [PMID: 34676416 DOI: 10.1093/jbcr/irab198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
9
Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume. MATERIALS 2021;14:ma14205991. [PMID: 34683583 PMCID: PMC8541548 DOI: 10.3390/ma14205991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 10/05/2021] [Accepted: 10/08/2021] [Indexed: 11/17/2022]
10
Influence of Mouthwash Rinsing on the Mechanical Properties of Polymeric Ligature Ties Used for Dental Applications. Polymers (Basel) 2021;13:polym13142236. [PMID: 34300994 PMCID: PMC8309248 DOI: 10.3390/polym13142236] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 06/30/2021] [Accepted: 07/04/2021] [Indexed: 11/17/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA