1
|
Avella P, Spiezia S, Rotondo M, Cappuccio M, Scacchi A, Inglese G, Guerra G, Brunese MC, Bianco P, Tedesco GA, Ceccarelli G, Rocca A. Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications. Cancers (Basel) 2025; 17:872. [PMID: 40075718 PMCID: PMC11898688 DOI: 10.3390/cancers17050872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2025] [Revised: 02/13/2025] [Accepted: 02/24/2025] [Indexed: 03/14/2025] Open
Abstract
BACKGROUND Indocyanine green (ICG) fluorescence has seen extensive application across medical and surgical fields, praised for its real-time navigation capabilities and low toxicity. Initially employed to assess liver function, ICG fluorescence is now integral to liver surgery, aiding in tumor detection, liver segmentation, and the visualization of bile leaks. This study reviews current protocols and ICG fluorescence applications in liver surgery, with a focus on optimizing timing and dosage based on clinical indications. METHODS Following PRISMA guidelines, we systematically reviewed the literature up to 27 January 2024, using PubMed and Medline to identify studies on ICG fluorescence used in liver surgery. A systematic review was performed to evaluate dosage and timing protocols for ICG administration. RESULTS Of 1093 initial articles, 140 studies, covering a total of 3739 patients, were included. The studies primarily addressed tumor detection (40%), liver segmentation (34.6%), and both (21.4%). The most common ICG fluorescence dose for tumor detection was 0.5 mg/kg, with administration occurring from days to weeks pre-surgery. Various near-infrared (NIR) camera systems were utilized, with the PINPOINT system most frequently cited. Tumor detection rates averaged 87.4%, with a 10.5% false-positive rate. Additional applications include the detection of bile leaks, lymph nodes, and vascular and biliary structures. CONCLUSIONS ICG fluorescence imaging has emerged as a valuable tool in liver surgery, enhancing real-time navigation and improving clinical outcomes. Standardizing protocols could further enhance ICG fluorescence efficacy and reliability, benefitting patient care in hepatic surgeries.
Collapse
Affiliation(s)
- Pasquale Avella
- Department of Clinical Medicine and Surgery, University of Naples “Federico II”, 80138 Naples, Italy
- Hepatobiliary and Pancreatic Surgery Unit, Department of General Surgery, Pineta Grande Hospital, 81030 Castel Volturno, Italy
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Salvatore Spiezia
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Marco Rotondo
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Micaela Cappuccio
- Department of Clinical Medicine and Surgery, University of Naples “Federico II”, 80138 Naples, Italy
| | - Andrea Scacchi
- School of Medicine and Surgery, University of Milano-Bicocca, 20126 Monza, Italy
| | - Giustiniano Inglese
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Germano Guerra
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Maria Chiara Brunese
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Paolo Bianco
- Hepatobiliary and Pancreatic Surgery Unit, Department of General Surgery, Pineta Grande Hospital, 81030 Castel Volturno, Italy
| | - Giuseppe Amedeo Tedesco
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| | - Graziano Ceccarelli
- Division of General and Minimally Invasive Surgery, Department of Surgery, San Giovanni Battista Hospital, 06034 Foligno, Italy
- Minimally Invasive and Robotic Surgery Unit, San Matteo Hospital, 06049 Spoleto, Italy
| | - Aldo Rocca
- Hepatobiliary and Pancreatic Surgery Unit, Department of General Surgery, Pineta Grande Hospital, 81030 Castel Volturno, Italy
- Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
| |
Collapse
|
2
|
Wakabayashi T, Cacciaguerra AB, Abe Y, Bona ED, Nicolini D, Mocchegiani F, Kabeshima Y, Vivarelli M, Wakabayashi G, Kitagawa Y. Indocyanine Green Fluorescence Navigation in Liver Surgery: A Systematic Review on Dose and Timing of Administration. Ann Surg 2022; 275:1025-1034. [PMID: 35121701 DOI: 10.1097/sla.0000000000005406] [Citation(s) in RCA: 84] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
BACKGROUND Indocyanine green (ICG) fluorescence has proven to be a high potential navigation tool during liver surgery; however, its optimal usage is still far from being standardized. METHODS A systematic review was conducted on MEDLINE/PubMed for English articles that contained the information of dose and timing of ICG administration until February 2021. Successful rates of tumor detection and liver segmentation, as well as tumor/patient background and imaging settings were also reviewed. The quality assessment of the articles was performed in accordance with the Scottish Intercollegiate Guidelines Network (SIGN). RESULTS Out of initial 311 articles, a total of 72 manuscripts were obtained. The quality assessment of the included studies revealed usually low; only 9 articles got qualified as high quality. Forty articles (55%) focused on open resections, whereas 32 articles (45%) on laparoscopic and robotic liver resections. Thirty-four articles (47%) described tumor detection ability, and 25 articles (35%) did liver segmentation ability, and the others (18%) did both abilities. Negative staining was reported (42%) more than positive staining (32%). For tumor detection, majority used the dose of 0.5 mg/kg within 14 days before the operation day, and an additional administration (0.02-0.5 mg/kg) in case of longer preoperative interval. Tumor detection rate was reported to be 87.4% (range, 43%-100%) with false positive rate reported to be 10.5% (range, 0%-31.3%). For negative staining method, the majority used 2.5 mg/body, ranging from 0.025 to 25 mg/body. For positive staining method, the majority used 0.25 mg/body, ranging from 0.025 to 12.5 mg/body. Successful segmentation rate was 88.0% (range, 53%-100%). CONCLUSION The time point and dose of ICG administration strongly needs to be tailored case by case in daily practice, due to various tumor/patient backgrounds and imaging settings.
Collapse
Affiliation(s)
- Taiga Wakabayashi
- Department of Surgery, Isehara Kyodo Hospital, Kanagawa, Japan
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
- Center for Advanced Treatment of Hepatobiliary and Pancreatic Diseases, Ageo Central General Hospital, Saitama, Japan
| | - Andrea Benedetti Cacciaguerra
- HPB Surgery and Transplantation Unit, Department of Clinical and Experimental Medicine, Polytechnic University of Marche, Ancona, Italy
| | - Yuta Abe
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| | - Enrico Dalla Bona
- HPB Surgery and Transplantation Unit, Department of Clinical and Experimental Medicine, Polytechnic University of Marche, Ancona, Italy
| | - Daniele Nicolini
- HPB Surgery and Transplantation Unit, Department of Clinical and Experimental Medicine, Polytechnic University of Marche, Ancona, Italy
| | - Federico Mocchegiani
- HPB Surgery and Transplantation Unit, Department of Clinical and Experimental Medicine, Polytechnic University of Marche, Ancona, Italy
| | - Yasuo Kabeshima
- Department of Surgery, Isehara Kyodo Hospital, Kanagawa, Japan
| | - Marco Vivarelli
- HPB Surgery and Transplantation Unit, Department of Clinical and Experimental Medicine, Polytechnic University of Marche, Ancona, Italy
| | - Go Wakabayashi
- Center for Advanced Treatment of Hepatobiliary and Pancreatic Diseases, Ageo Central General Hospital, Saitama, Japan
| | - Yuko Kitagawa
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
3
|
Hettie KS. Targeting Contrast Agents With Peak Near-Infrared-II (NIR-II) Fluorescence Emission for Non-invasive Real-Time Direct Visualization of Thrombosis. Front Mol Biosci 2021; 8:670251. [PMID: 34026844 PMCID: PMC8138325 DOI: 10.3389/fmolb.2021.670251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 04/12/2021] [Indexed: 11/17/2022] Open
Abstract
Thrombosis within the vasculature arises when pathological factors compromise normal hemostasis. On doing so, arterial thrombosis (AT) and venous thrombosis (VT) can lead to life-threatening cardio-cerebrovascular complications. Unfortunately, the therapeutic window following the onset of AT and VT is insufficient for effective treatment. As such, acute AT is the leading cause of heart attacks and constitutes ∼80% of stroke incidences, while acute VT can lead to fatal therapy complications. Early lesion detection, their accurate identification, and the subsequent appropriate treatment of thrombi can reduce the risk of thrombosis as well as its sequelae. As the success rate of therapy of fresh thrombi is higher than that of old thrombi, detection of the former and accurate identification of lesions as thrombi are of paramount importance. Magnetic resonance imaging, x-ray computed tomography (CT), and ultrasound (US) are the conventional non-invasive imaging modalities used for the detection and identification of AT and VT, but these modalities have the drawback of providing only image-delayed indirect visualization of only late stages of thrombi development. To overcome such limitations, near-infrared (NIR, ca. 700-1,700 nm) fluorescence (NIRF) imaging has been implemented due to its capability of providing non-invasive real-time direct visualization of biological structures and processes. Contrast agents designed for providing real-time direct or indirect visualization of thrombi using NIRF imaging primarily provide peak NIR-I fluorescence emission (ca. 700-1,000 nm), which affords limited tissue penetration depth and suboptimal spatiotemporal resolution. To facilitate the enhancement of the visualization of thrombosis via providing detection of smaller, fresh, and/or deep-seated thrombi in real time, the development of contrast agents with peak NIR-II fluorescence emission (ca. 1000-1,700 nm) has been recently underway. Currently, however, most contrast agents that provide peak NIR-II fluorescence emissions that are purportedly capable of providing direct visualization of thrombi or their resultant occlusions actually afford only the indirect visualization of such because they only provide for the (i) measuring of the surrounding vascular blood flow and/or (ii) simple tracing of the vasculature. These contrast agents do not target thrombi or occlusions. As such, this mini review summarizes the extremely limited number of targeting contrast agents with peak NIR-II fluorescence emission developed for non-invasive real-time direct visualization of thrombosis that have been recently reported.
Collapse
Affiliation(s)
- Kenneth S. Hettie
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, United States
- Department of Otolaryngology - Head and Neck Surgery, Stanford University, Stanford, CA, United States
| |
Collapse
|