1
|
Savin L, Pinteala T, Mihai DN, Mihailescu D, Miu SS, Sirbu MT, Veliceasa B, Popescu DC, Sirbu PD, Forna N. Updates on Biomaterials Used in Total Hip Arthroplasty (THA). Polymers (Basel) 2023; 15:3278. [PMID: 37571172 PMCID: PMC10422432 DOI: 10.3390/polym15153278] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 07/30/2023] [Accepted: 07/31/2023] [Indexed: 08/13/2023] Open
Abstract
One of the most popular and effective orthopedic surgical interventions for treating a variety of hip diseases is total hip arthroplasty. Despite being a radical procedure that involves replacing bone and cartilaginous surfaces with biomaterials, it produces excellent outcomes that significantly increase the patient's quality of life. Patient factors and surgical technique, as well as biomaterials, play a role in prosthetic survival, with aseptic loosening (one of the most common causes of total hip arthroplasty failure) being linked to the quality of biomaterials utilized. Over the years, various biomaterials have been developed to limit the amount of wear particles generated over time by friction between the prosthetic head (metal alloys or ceramic) and the insert fixed in the acetabular component (polyethylene or ceramic). An ideal biomaterial must be biocompatible, have a low coefficient of friction, be corrosion resistant, and have great mechanical power. Comprehensive knowledge regarding what causes hip arthroplasty failure, as well as improvements in biomaterial quality and surgical technique, will influence the survivability of the prosthetic implant. The purpose of this article was to assess the benefits and drawbacks of various biomaterial and friction couples used in total hip arthroplasties by reviewing the scientific literature published over the last 10 years.
Collapse
Affiliation(s)
- Liliana Savin
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Tudor Pinteala
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Dana Nicoleta Mihai
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
- Department of Protheses Technology, Faculty of Dental Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Dan Mihailescu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Smaranda Stefana Miu
- Department of Rehabilitation, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Mihnea Theodor Sirbu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Bogdan Veliceasa
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Dragos Cristian Popescu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
| | - Paul Dan Sirbu
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| | - Norin Forna
- Department of Orthopedics and Traumatology, Faculty of Medicine, “Grigore T. Popa” University of Medicine and Pharmacy, 700115 Iasi, Romania; (L.S.); (D.M.); (M.T.S.); (B.V.); (D.C.P.); (P.D.S.); (N.F.)
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania;
| |
Collapse
|
2
|
Wilson JM, Maradit-Kremers H, Abdel MP, Berry DJ, Mabry TM, Pagnano MW, Perry KI, Sierra RJ, Taunton MJ, Trousdale RT, Lewallen DG. Comparative Survival of Contemporary Cementless Acetabular Components Following Revision Total Hip Arthroplasty. J Arthroplasty 2023; 38:S194-S200. [PMID: 37028772 PMCID: PMC10330048 DOI: 10.1016/j.arth.2023.03.093] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 03/28/2023] [Accepted: 03/30/2023] [Indexed: 04/09/2023] Open
Abstract
BACKGROUND The advent of highly porous ingrowth surfaces and highly crosslinked polyethylene has been expected to improve implant survivorship in revision total hip arthroplasty. Therefore, we sought to evaluate the survival of several contemporary acetabular designs following revision total hip arthroplasty. METHODS Acetabular revisions performed from 2000 to 2019 were identified from our institutional total joint registry. We studied 3,348 revision hips, implanted with 1 of 7 cementless acetabular designs. These were paired with highly crosslinked polyethylene or dual-mobility liners. A historical series of 258 Harris-Galante-1 components, paired with conventional polyethylene, was used as reference. Survivorship analyses were performed. For the 2,976 hips with minimum 2-year follow-up, the median follow-up was 8 years (range, 2 to 35 years). RESULTS Contemporary components with adequate follow-up had survivorship free of acetabular rerevision of ≥95% at 10-year follow-up. Relative to Harris-Galante-1 components, 10-year survivorship free of all-cause acetabular cup rerevision was significantly higher in Zimmer Trabecular Metarevision (hazard ratio (HR) 0.3, 95% confidence interval (CI) 0.2-0.45), Zimmer Trabecular MetaModular (HR 0.34, 95% CI 0.13-0.89), Zimmer Trilogy (HR 0.4, 95% CI 0.24-0.69), DePuy Pinnacle Porocoat (HR 0.24, 95% CI 0.11-0.51), and Stryker Tritanium revision (HR 0.46, 95% CI 0.24-0.91) shells. Among contemporary components, there were only 23 rerevisions for acetabular aseptic loosening and no rerevisions for polyethylene wear. CONCLUSION Contemporary acetabular ingrowth and bearing surfaces were associated with no rerevisions for wear and aseptic loosening was uncommon, particularly with highly porous designs. Therefore, it appears that contemporary revision acetabular components have dramatically improved upon historical results at available follow-up.
Collapse
Affiliation(s)
- Jacob M Wilson
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Tad M Mabry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Mark W Pagnano
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Kevin I Perry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | | | - David G Lewallen
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
3
|
Langlois J, Hamadouche M. What have we learned from 20 years of using highly crosslinked PE in total hip arthroplasty? Orthop Traumatol Surg Res 2023; 109:103457. [PMID: 36302450 DOI: 10.1016/j.otsr.2022.103457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 05/11/2022] [Accepted: 05/12/2022] [Indexed: 11/07/2022]
Abstract
Slightly more than 20 years after its first clinical use, highly cross-linked polyethylene (HXLPE) has been widely adopted. Despite initial concerns about oxidation and lack of fatigue resistance, first generation HXLPE, with 15 years of follow-up and widespread use, continues to provide excellent results, even in a young, active population. Remelted HXLPE might have a lower wear rate than annealed HXLPE and will no doubt have a better resistance to oxidation. Second generation materials, consisting of polyethylene (PE) that is sequentially irradiated then annealed and PE that is infused with antioxidants, also have provided encouraging short- and medium-term results. Data from national joint registers confirm data from clinical trials. Even in more challenging cases (dual mobility, hip resurfacing, revision surgery and thin liners), HXLPE has generated promising results. However, failures (rim fractures) have been documented, including for all the latest HXLPE generations. Consequently, certain precautions must be taken during its use and close patient monitoring is necessary.
Collapse
Affiliation(s)
- Jean Langlois
- Centre Orthopédique Santy, 24, avenue Paul Santy, Lyon, France; Hôpital Privé Jean-Mermoz, 55, avenue Jean-Mermoz, Lyon, France.
| | - Moussa Hamadouche
- Département de Chirurgie Orthopédique, Université de Paris, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin, 27, rue du Faubourg Saint-Jacques, Paris, France
| |
Collapse
|
4
|
Cho K, Park CW, Jeong SJ, Lee JH, Lim SJ, Park YS. Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty. J Arthroplasty 2023:S0883-5403(23)00048-7. [PMID: 36709880 DOI: 10.1016/j.arth.2023.01.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 01/18/2023] [Accepted: 01/20/2023] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.
Collapse
Affiliation(s)
- Kyungjun Cho
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Chan-Woo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Sang Jin Jeong
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Jong-Hyun Lee
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Seung-Jae Lim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea
| |
Collapse
|
5
|
Hosseinzadeh S. Outcomes of Cementing an Acetabular Liner into a Secure Shell Over Time: Commentary on an article by Nicholas A. Bedard, MD, et al.: "Intermediate to Long-Term Follow-up of Cementing Liners into Well-Fixed Acetabular Components". J Bone Joint Surg Am 2020; 102:e97. [PMID: 32815853 DOI: 10.2106/jbjs.20.00997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Shayan Hosseinzadeh
- Department of Orthopaedic Surgery, Boston Children's Hospital, Boston, Massachusetts.,Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
6
|
Langlois J, Hamadouche M. Recent update on crosslinked polyethylene in total hip arthroplasty. SICOT J 2020; 6:13. [PMID: 32412408 PMCID: PMC7227368 DOI: 10.1051/sicotj/2020013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 04/23/2020] [Indexed: 02/02/2023] Open
Abstract
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial.
Collapse
Affiliation(s)
- Jean Langlois
-
Centre Orthopédique Santy 24, avenue Paul Santy 69008 Lyon France
-
Hôpital Privé Jean-Mermoz 55, avenue Jean-Mermoz 69008 Lyon France
| | - Moussa Hamadouche
-
Département de Chirurgie Orthopédique, Université Paris-Descartes, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin 27, rue du Faubourg Saint-Jacques 75014 Paris France
| |
Collapse
|