1
|
Liang L, Zimmermann Rollin I, Alikaya A, Ho JC, Santini T, Bostan AC, Schwerdt HN, Stauffer WR, Ibrahim TS, Pirondini E, Schaeffer DJ. An open-source MRI compatible frame for multimodal presurgical mapping in macaque and capuchin monkeys. J Neurosci Methods 2024; 407:110133. [PMID: 38588922 PMCID: PMC11127775 DOI: 10.1016/j.jneumeth.2024.110133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 03/06/2024] [Accepted: 04/03/2024] [Indexed: 04/10/2024]
Abstract
BACKGROUND High-precision neurosurgical targeting in nonhuman primates (NHPs) often requires presurgical anatomical mapping with noninvasive neuroimaging techniques (MRI, CT, PET), allowing for translation of individual anatomical coordinates to surgical stereotaxic apparatus. Given the varied tissue contrasts that these imaging techniques produce, precise alignment of imaging-based coordinates to surgical apparatus can be cumbersome. MRI-compatible stereotaxis with radiopaque fiducial markers offer a straight-forward and reliable solution, but existing commercial options do not fit in conformal head coils that maximize imaging quality. NEW METHOD We developed a compact MRI-compatible stereotaxis suitable for a variety of NHP species (Macaca mulatta, Macaca fascicularis, and Cebus apella) that allows multimodal alignment through technique-specific fiducial markers. COMPARISON WITH EXISTING METHODS With the express purpose of compatibility with clinically available MRI, CT, and PET systems, the frame is no larger than a human head, while allowing for imaging NHPs in the supinated position. This design requires no marker implantation, special software, or additional knowledge other than the operation of a common large animal stereotaxis. RESULTS We demonstrated the applicability of this 3D-printable apparatus across a diverse set of experiments requiring presurgical planning: 1) We demonstrate the accuracy of the fiducial system through a within-MRI cannula insertion and subcortical injection of a viral vector. 2) We also demonstrated accuracy of multimodal (MRI and CT) alignment and coordinate transfer to guide a surgical robot electrode implantation for deep-brain electrophysiology. CONCLUSIONS The computer-aided design files and engineering drawings are publicly available, with the modular design allowing for low cost and manageable manufacturing.
Collapse
Affiliation(s)
- Lucy Liang
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neural Basis of Cognition, Pittsburgh, PA, USA
| | - Isabela Zimmermann Rollin
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neural Basis of Cognition, Pittsburgh, PA, USA; Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Aydin Alikaya
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD, USA
| | - Jonathan C Ho
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA; School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Tales Santini
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Andreea C Bostan
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD, USA
| | - Helen N Schwerdt
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD, USA
| | - William R Stauffer
- Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD, USA
| | - Tamer S Ibrahim
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; University of Pittsburgh, Psychiatry, Pittsburgh, PA, USA; University of Pittsburgh, Radiology, Pittsburgh, PA, USA
| | - Elvira Pirondini
- Rehab Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Center for Neural Basis of Cognition, Pittsburgh, PA, USA; Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Physical Medicine & Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA; Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA, USA
| | - David J Schaeffer
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Department of Neurobiology, University of Pittsburgh, Pittsburgh, PA, USA; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD, USA.
| |
Collapse
|
2
|
Pigorini A, Avanzini P, Barborica A, Bénar CG, David O, Farisco M, Keller CJ, Manfridi A, Mikulan E, Paulk AC, Roehri N, Subramanian A, Vulliémoz S, Zelmann R. Simultaneous invasive and non-invasive recordings in humans: A novel Rosetta stone for deciphering brain activity. J Neurosci Methods 2024; 408:110160. [PMID: 38734149 DOI: 10.1016/j.jneumeth.2024.110160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 04/10/2024] [Accepted: 05/01/2024] [Indexed: 05/13/2024]
Abstract
Simultaneous noninvasive and invasive electrophysiological recordings provide a unique opportunity to achieve a comprehensive understanding of human brain activity, much like a Rosetta stone for human neuroscience. In this review we focus on the increasingly-used powerful combination of intracranial electroencephalography (iEEG) with scalp electroencephalography (EEG) or magnetoencephalography (MEG). We first provide practical insight on how to achieve these technically challenging recordings. We then provide examples from clinical research on how simultaneous recordings are advancing our understanding of epilepsy. This is followed by the illustration of how human neuroscience and methodological advances could benefit from these simultaneous recordings. We conclude with a call for open data sharing and collaboration, while ensuring neuroethical approaches and argue that only with a true collaborative approach the promises of simultaneous recordings will be fulfilled.
Collapse
Affiliation(s)
- Andrea Pigorini
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan, Italy; UOC Maxillo-facial Surgery and dentistry, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy.
| | - Pietro Avanzini
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | | | - Christian-G Bénar
- Aix Marseille Univ, Inserm, U1106, INS, Institut de Neurosciences des Systèmes, Marseille, France
| | - Olivier David
- Aix Marseille Univ, Inserm, U1106, INS, Institut de Neurosciences des Systèmes, Marseille, France
| | - Michele Farisco
- Centre for Research Ethics and Bioethics, Department of Public Health and Caring Sciences, Uppsala University, P.O. Box 256, Uppsala, SE 751 05, Sweden; Science and Society Unit Biogem, Biology and Molecular Genetics Institute, Via Camporeale snc, Ariano Irpino, AV 83031, Italy
| | - Corey J Keller
- Department of Psychiatry & Behavioral Sciences, Stanford University Medical Center, Stanford, CA 94305, USA; Wu Tsai Neurosciences Institute, Stanford University Medical Center, Stanford, CA 94305, USA; Veterans Affairs Palo Alto Healthcare System, and the Sierra Pacific Mental Illness, Research, Education, and Clinical Center (MIRECC), Palo Alto, CA 94394, USA
| | - Alfredo Manfridi
- Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Milan, Italy
| | - Ezequiel Mikulan
- Department of Health Sciences, Università degli Studi di Milano, Milan, Italy
| | - Angelique C Paulk
- Department of Neurology and Center for Neurotechnology and Neurorecovery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Nicolas Roehri
- EEG and Epilepsy Unit, Dpt of Clinical Neurosciences, Geneva University Hospitals and University of Geneva, Switzerland
| | - Ajay Subramanian
- Department of Psychiatry & Behavioral Sciences, Stanford University Medical Center, Stanford, CA 94305, USA; Wu Tsai Neurosciences Institute, Stanford University Medical Center, Stanford, CA 94305, USA; Veterans Affairs Palo Alto Healthcare System, and the Sierra Pacific Mental Illness, Research, Education, and Clinical Center (MIRECC), Palo Alto, CA 94394, USA
| | - Serge Vulliémoz
- EEG and Epilepsy Unit, Dpt of Clinical Neurosciences, Geneva University Hospitals and University of Geneva, Switzerland
| | - Rina Zelmann
- Department of Neurology and Center for Neurotechnology and Neurorecovery, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
3
|
Muh CR, Dorilio JR, Beaudreault CP, McGoldrick PE, Pisapia JM, Wolf SM. Feasibility and safety of stereoelectroencephalography in young children. Childs Nerv Syst 2024; 40:1331-1337. [PMID: 38451299 DOI: 10.1007/s00381-024-06335-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 02/23/2024] [Indexed: 03/08/2024]
Abstract
PURPOSE Stereoelectroencephalography (SEEG) is a diagnostic surgery that implants electrodes to identify areas of epileptic onset in patients with drug-resistant epilepsy (DRE). SEEG is effective in identifying the epileptic zone; however, placement of electrodes in very young children has been considered contraindicated due to skull thinness. The goal of this study was to evaluate if SEEG is safe and accurate in young children with thin skulls. METHODS Four children under the age of two years old with DRE underwent SEEG to locate the region of seizure onset. Presurgical planning and placement of electrodes were performed using ROSA One Brain. Preoperative electrode plans were merged with postoperative CT scans to determine accuracy. Euclidean distance between the planned and actual trajectories was calculated using a 3D coordinate system at both the entry and target points for each electrode. RESULTS Sixty-three electrodes were placed among four patients. Mean skull thickness at electrode entry sites was 2.34 mm. The mean difference between the planned and actual entry points was 1.12 mm, and the mean difference between the planned and actual target points was 1.73 mm. No significant correlation was observed between planned and actual target points and skull thickness (Pearson R = - 0.170). No perioperative or postoperative complications were observed. CONCLUSIONS This study demonstrates that SEEG can be safe and accurate in children under two years of age despite thin skulls. SEEG should be considered for young children with DRE, and age and skull thickness are not definite contraindications to the surgery.
Collapse
Affiliation(s)
- Carrie R Muh
- Department of Neurosurgery and Department of Pediatrics, Westchester Medical Center, 100 Woods Road, Taylor Pavilion E135, Valhalla, NY, 10595, USA.
- Department of Neurosurgery, New York Medical College, Valhalla, NY, 10595, USA.
| | | | | | - Patricia E McGoldrick
- Department of Pediatric Neurology, Boston Children's Health Physicians, Hawthorne, NY, USA
| | - Jared M Pisapia
- Department of Neurosurgery and Department of Pediatrics, Westchester Medical Center, 100 Woods Road, Taylor Pavilion E135, Valhalla, NY, 10595, USA
- Department of Neurosurgery, New York Medical College, Valhalla, NY, 10595, USA
| | - Steven M Wolf
- Department of Pediatric Neurology, Boston Children's Health Physicians, Hawthorne, NY, USA
- Department of Neurology, New York Medical College, Valhalla, NY, USA
| |
Collapse
|
4
|
Di Giacomo R, Burini A, Chiarello D, Pelliccia V, Deleo F, Garbelli R, de Curtis M, Tassi L, Gnatkovsky V. Ictal fast activity chirps as markers of the epileptogenic zone. Epilepsia 2024. [PMID: 38686942 DOI: 10.1111/epi.17995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 04/11/2024] [Accepted: 04/11/2024] [Indexed: 05/02/2024]
Abstract
The identification of the epileptogenic zone (EZ) boundaries is crucial for effective focal epilepsy surgery. We verify the value of a neurophysiological biomarker of focal ictogenesis, characterized by a low-voltage fast-activity ictal pattern (chirp) recorded with intracerebral electrodes during invasive presurgical monitoring (stereoelectroencephalography [SEEG]). The frequency content of SEEG signals was retrospectively analyzed with semiautomatic software in 176 consecutive patients with focal epilepsies that either were cryptogenic or presented with discordant anatomoelectroclinical findings. Fast activity seizure patterns with the spectrographic features of chirps were confirmed by computer-assisted analysis in 95.4% of patients who presented with heterogeneous etiologies and diverse lobar location of the EZ. Statistical analysis demonstrated (1) correlation between seizure outcome and concordance of sublobar regions included in the EZ defined by visual analysis and chirp-generating regions, (2) high concordance in contact-by contact analysis of 68 patients with Engel class Ia outcome, and (3) that discordance between chirp location and the visually outlined EZ correlated with worse seizure outcome. Seizure outcome analysis confirms the fast activity chirp pattern is a reproducible biomarker of the EZ in a heterogeneous group of patients undergoing SEEG.
Collapse
Affiliation(s)
- Roberta Di Giacomo
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Alessandra Burini
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
- Clinical Neurology, Department of Medicine (DAME), University of Udine, Udine, Italy
| | - Daniela Chiarello
- "Claudio Munari" Epilepsy Surgery Center, Niguarda Hospital, Milan, Italy
| | - Veronica Pelliccia
- "Claudio Munari" Epilepsy Surgery Center, Niguarda Hospital, Milan, Italy
| | - Francesco Deleo
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Rita Garbelli
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Marco de Curtis
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Laura Tassi
- "Claudio Munari" Epilepsy Surgery Center, Niguarda Hospital, Milan, Italy
| | - Vadym Gnatkovsky
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
- Department of Epileptology, Universitätsklinikum Bonn, Bonn, Germany
| |
Collapse
|
5
|
Sharma A, Song R, Sarmey N, Harasimchuk S, Bulacio J, Pucci F, Rammo R, Bingaman W, Serletis D. Validation and Safety Profile of a Novel, Noninvasive Fiducial Attachment for Stereotactic Robotic-Guided Stereoelectroencephalography: A Case Series. Oper Neurosurg (Hagerstown) 2024:01787389-990000000-01137. [PMID: 38651866 DOI: 10.1227/ons.0000000000001148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Accepted: 02/06/2024] [Indexed: 04/25/2024] Open
Abstract
BACKGROUND AND OBJECTIVES We developed, tested, and validated a novel, noninvasive, Leksell G frame-based fiducial attachment, for use in stereotactic registration for stereoelectroencephalography (sEEG). Use of the device increased the number of fixed reference points available for registration, while obviating the need for additional scalp incisions. We report here on our experience and safety profile of using the device. METHODS We collected registration data using the fiducial device across 25 adult and pediatric patients with epilepsy consecutively undergoing robotic-guided sEEG for invasive epilepsy monitoring, treated between May 2022 and July 2023. ROSA One Brain was used for trajectory planning and electrode implantation. Postoperative clinical and radiographic data were computed and quantified, including mean registration error for all patients. Entry point, target point (TP), and angular errors were measured. Descriptive statistics and correlation coefficients for error were calculated. RESULTS Twenty-five patients underwent robotic-guided sEEG implantation (11 patients, bilateral; 10 patients, left unilateral; 4 patients, right). The mean number of electrodes per patient was 18 ± 3. The average mean registration error was 0.77 ± 0.11 mm. All patients were implanted with Ad-Tech depth electrodes. No clinically relevant complications were reported. Analysis of trajectory error was performed on 446 electrodes. The median entry point error was 1.03 mm (IQR 0.69-1.54). The median TP error was 2.26 mm (IQR 1.63-2.93). The mean angular error was 0.03 radians (IQR 0.02-0.05). There was no significant correlation between root mean square error and lead error. Root mean square error did not appreciably change over time, nor were there any significant changes in average angular, entry point, or TP error metrics. CONCLUSION A novel, noninvasive, Leksell G frame-based fiducial attachment was developed, tested, and validated, facilitating O-arm-based stereotactic registration for sEEG. This simple innovation maintained an excellent accuracy and safety profile for sEEG procedures in epilepsy patients, with the added advantages of providing additional reference points for stereotactic registration, without requiring additional scalp incisions.
Collapse
Affiliation(s)
- Akshay Sharma
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Ryan Song
- Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Nehaw Sarmey
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Stephen Harasimchuk
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Juan Bulacio
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Francesco Pucci
- Department of Neurosurgery, University of Illinois, Chicago, Chicago, Illinois, USA
| | - Richard Rammo
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - William Bingaman
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Demitre Serletis
- Cleveland Clinic Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
6
|
Muto J, Tateya I, Nakatomi H, Uyama I, Hirose Y. Transoral Robotic-Assisted Neurosurgery for Skull Base and Upper Spine Lesions. Neurospine 2024; 21:106-115. [PMID: 38569637 PMCID: PMC10992650 DOI: 10.14245/ns.2448062.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 02/24/2024] [Accepted: 02/26/2024] [Indexed: 04/05/2024] Open
Abstract
OBJECTIVE The application of the da Vinci Surgical System in neurosurgery is limited due to technical difficulties requiring precise maneuvers and small instruments. This study details the advantages and disadvantages of robotics in neurosurgery and the reachable range of the transoral approach to lesions of the skull base and upper cervical spine. METHODS In a cadaver study, the da Vinci Xi robot, lacking haptic feedback, was utilized for sagittal and coronal approaches on 5 heads, facilitating dura suturing in 3, with a 30°-angled drill for bone removal. RESULTS Perfect exposure of all the nasopharyngeal sites, clivus, sellar, and choana, including the bilateral eustachian tubes, was achieved without any external incisions using this palatal split approach of transoral robotic surgery. The time required to perform a single stitch, knot, and complete single suture in robotic suturing of deep-seated were significantly less compared to manual suturing via the endonasal approach. CONCLUSION This is the first report to show the feasibility of suturing the dural defect in deep-seated lesions transorally and revealed that the limit of reach in the coronal plane via a transoral approach with incision of the soft palate is the foramen ovale. This preclinical investigation also showed that the transoral robotic approach is feasible for lesions extending from the sellar to the C2 in the sagittal plane. Refinement of robotic instruments for specific anatomic sites and future neurosurgical studies are needed to further demonstrate the feasibility and effectiveness of this system in treating benign and malignant skull base lesions.
Collapse
Affiliation(s)
- Jun Muto
- Department of Neurosurgery, Fujita Health University, Aichi, Japan
| | - Ichiro Tateya
- Department of Otolaryngology-Head and Neck Surgery, Fujita Health University, Aichi, Japan
| | | | - Ichiro Uyama
- Department of General Surgery, Fujita Health University, Aichi, Japan
| | - Yuichi Hirose
- Department of Neurosurgery, Fujita Health University, Aichi, Japan
| |
Collapse
|
7
|
Kullmann A, Akberali F, Van Gompel JJ, McGovern RA, Marsh WR, Kridner D, Diaz-Botia CA, Park MC. Implantation accuracy of novel polyimide stereotactic electroencephalographic depth electrodes-a human cadaveric study. FRONTIERS IN MEDICAL TECHNOLOGY 2024; 6:1320762. [PMID: 38456122 PMCID: PMC10917981 DOI: 10.3389/fmedt.2024.1320762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 02/12/2024] [Indexed: 03/09/2024] Open
Abstract
Introduction Stereoelectroencephalography (sEEG) is a minimally invasive procedure that uses depth electrodes stereotactically implanted into brain structures to map the origin and propagation of seizures in epileptic patients. Implantation accuracy of sEEG electrodes plays a critical role in the safety and efficacy of the procedure. This study used human cadaver heads, simulating clinical practice, to evaluate (1) neurosurgeon's ability to implant a new thin-film polyimide sEEG electrode according to the instructions for use (IFU), and (2) implantation accuracy. Methods Four neurosurgeons (users) implanted 24 sEEG electrodes into two cadaver heads with the aid of the ROSA robotic system. Usability was evaluated using a questionnaire that assessed completion of all procedure steps per IFU and user errors. For implantation accuracy evaluation, planned electrode trajectories were compared with post-implantation trajectories after fusion of pre- and postoperative computer tomography (CT) images. Implantation accuracy was quantified using the Euclidean distance for entry point error (EPE) and target point error (TPE). Results All sEEG electrodes were successfully placed following the IFU without user errors, and post-implant survey of users showed favorable handling characteristics. The EPE was 1.28 ± 0.86 mm and TPE was 1.61 ± 0.89 mm. Long trajectories (>50 mm) had significantly larger EPEs and TPEs than short trajectories (<50 mm), and no differences were found between orthogonal and oblique trajectories. Accuracies were similar or superior to those reported in the literature when using similar experimental conditions, and in the same range as those reported in patients. Discussion The results demonstrate that newly developed polyimide sEEG electrodes can be implanted as accurately as similar devices in the marker without user errors when following the IFU in a simulated clinical environment. The human cadaver ex-vivo test system provided a realistic test system, owing to the size, anatomy and similarity of tissue composition to that of the live human brain.
Collapse
Affiliation(s)
- Aura Kullmann
- NeuroOne Medical Technologies, Eden Prairie, MN, United States
| | | | | | - Robert A. McGovern
- Department of Neurosurgery, University of Minnesota Medical Center, Minneapolis, MN, United States
| | - W. Richard Marsh
- Department of Neurosurgery, Mayo Clinic, Rochester, MN, United States
| | - Debra Kridner
- NeuroOne Medical Technologies, Eden Prairie, MN, United States
| | | | - Michael C. Park
- Department of Neurosurgery, University of Minnesota Medical Center, Minneapolis, MN, United States
- Department of Neurology, University of Minnesota Medical Center, Minneapolis, MN, United States
| |
Collapse
|
8
|
Han CL, Chou CC, Chen HH, Chen YH, Lin CF, Chen C, Yu HY, Chen YW, Lee CC. Frame-based versus robot-assisted stereo-electro-encephalography for drug-resistant epilepsy. Acta Neurochir (Wien) 2024; 166:85. [PMID: 38361129 DOI: 10.1007/s00701-024-05983-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 01/11/2024] [Indexed: 02/17/2024]
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) is an effective presurgical invasive evaluation for drug-resistant epilepsies. The introduction of robotic devices provides a simplified, accurate, and safe alternative to the conventional SEEG technique. We report our institutional experience with robot-assisted SEEG and compare its in vivo accuracy, operation efficiency, and safety with the more traditional SEEG workflow. METHODS All patients with medically refractory focal epilepsy who underwent SEEG depth electrode implantation between 2014 and 2022 were included in this study. Technical advancements of the robot-assisted technique are described. Analyses of patient demographics, electrode implantation accuracy, operation time, and procedure-related complications were performed. RESULTS One hundred and sixty-six patients underwent 167 SEEG procedures. The first 141 procedures were performed using a conventional approach involving a Leksell stereotactic system, and the last 26 procedures were robot-assisted. Among the 1726 depth electrodes that were inserted, the median entry point localization error was as follows: conventional (1.0 mm; range, 0.1-33.5 mm) and robot-assisted (1.1 mm; range, 0-4.8 mm) (P = 0.17). The median target point localization error was as follows: conventional (2.8 mm; range, 0.1-49 mm) and robot-assisted (1.8 mm; range, 0-30.3 mm) (P < 0.001). The median operation time was significantly reduced with the robot-assisted workflow (90 min vs. 77.5 min; P < 0.01). Total complication rates were as follows: conventional (17.7%) and robot-assisted (11.5%) (P = 0.57). Major complication rates were 3.5% and 7.7% (P = 0.77), respectively. CONCLUSIONS SEEG is a safe and highly accurate method that provides essential guidance for epilepsy surgery. Implementing SEEG in conjunction with multimodal planning systems and robotic devices can further increase safety margin, surgical efficiency, and accuracy.
Collapse
Affiliation(s)
- Chang-Lin Han
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Chien-Chen Chou
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Hsin-Hung Chen
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Yi-Hsiu Chen
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Chun-Fu Lin
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chien Chen
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Hsiang-Yu Yu
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Yu-Wei Chen
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Cheng-Chia Lee
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| |
Collapse
|
9
|
Kaewborisutsakul A, Chernov M, Yokosako S, Kubota Y. Usefulness of Robotic Stereotactic Assistance (ROSA ®) Device for Stereoelectroencephalography Electrode Implantation: A Systematic Review and Meta-analysis. Neurol Med Chir (Tokyo) 2024; 64:71-86. [PMID: 38220166 PMCID: PMC10918457 DOI: 10.2176/jns-nmc.2023-0119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 10/17/2023] [Indexed: 01/16/2024] Open
Abstract
The aim of this study was to systematically review and meta-analyze the efficiency and safety of using the Robotic Stereotactic Assistance (ROSA®) device (Zimmer Biomet; Warsaw, IN, USA) for stereoelectroencephalography (SEEG) electrode implantation in patients with drug-resistant epilepsy. Based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a literature search was carried out. Overall, 855 nonduplicate relevant articles were determined, and 15 of them were selected for analysis. The benefits of the ROSA® device use in terms of electrode placement accuracy, as well as operative time length, perioperative complications, and seizure outcomes, were evaluated. Studies that were included reported on a total of 11,257 SEEG electrode implantations. The limited number of comparative studies hindered the comprehensive evaluation of the electrode implantation accuracy. Compared with frame-based or navigation-assisted techniques, ROSA®-assisted SEEG electrode implantation provided significant benefits for reduction of both overall operative time (mean difference [MD], -63.45 min; 95% confidence interval [CI] from -88.73 to -38.17 min; P < 0.00001) and operative time per implanted electrode (MD, -8.79 min; 95% CI from -14.37 to -3.21 min; P = 0.002). No significant differences existed in perioperative complications and seizure outcomes after the application of the ROSA® device and other techniques for electrode implantation. To conclude, the available evidence shows that the ROSA® device is an effective and safe surgical tool for trajectory-guided SEEG electrode implantation in patients with drug-resistant epilepsy, offering benefits for saving operative time and neither increasing the risk of perioperative complications nor negatively impacting seizure outcomes.
Collapse
Affiliation(s)
- Anukoon Kaewborisutsakul
- Neurological Surgery Unit, Division of Surgery, Faculty of Medicine, Prince of Songkla University
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| | - Mikhail Chernov
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| | - Suguru Yokosako
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| | - Yuichi Kubota
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| |
Collapse
|
10
|
Niznik T, Grossen A, Shi H, Stephens M, Herren C, Desai VR. Learning Curve in Robotic Stereoelectroencephalography: Single Platform Experience. World Neurosurg 2024; 182:e442-e452. [PMID: 38030071 DOI: 10.1016/j.wneu.2023.11.119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 12/01/2023]
Abstract
BACKGROUND Learning curve, training, and cost impede widespread implementation of new technology. Neurosurgical robotic technology introduces challenges to visuospatial reasoning and requires the acquisition of new fine motor skills. Studies detailing operative workflow, learning curve, and patient outcomes are needed to describe the utility and cost-effectiveness of new robotic technology. METHODS A retrospective analysis was performed of pediatric patients who underwent robotic stereoelectroencephalography (sEEG) with the Medtronic Stealth Autoguide. Workflow, total operative time, and time per electrode were evaluated alongside target accuracy assessed via error measurements and root sum square. Patient demographics and clinical outcomes related to sEEG were also assessed. RESULTS Robot-assisted sEEG was performed in 12 pediatric patients. Comparison of cases over time demonstrated a mean operative time of 363.3 ± 109.5 minutes for the first 6 cases and 256.3 ± 59.1 minutes for the second 6 cases, with reduced operative time per electrode (P = 0.037). Mean entry point error, target point error, and depth point error were 1.82 ± 0.77 mm, 2.26 ± 0.71 mm, and 1.27 ± 0.53 mm, respectively, with mean root sum square of 3.23 ± 0.97 mm. Error measurements between magnetic resonance imaging and computed tomography angiography found computed tomography angiography to be more accurate with significant differences in mean entry point error (P = 0.043) and mean target point error (P = 0.035). The epileptogenic zone was identified in 11 patients, with therapeutic surgeries following in 9 patients, of whom 78% achieved an Engel class I. CONCLUSIONS This study demonstrated institutional workflow evolution and learning curve for the Autoguide in pediatric sEEG, resulting in reduced operative times and increased accuracy over a small number of cases. The platform may seamlessly and quickly be incorporated into clinical practice, and the provided workflow can facilitate a smooth transition.
Collapse
Affiliation(s)
- Taylor Niznik
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Audrey Grossen
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Helen Shi
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Mark Stephens
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Cherie Herren
- Department of Neurology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA
| | - Virendra R Desai
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA.
| |
Collapse
|
11
|
Buch VP, Parvizi J. Evolution of SEEG Strategy: Stanford Experience. Neurosurg Clin N Am 2024; 35:83-85. [PMID: 38000844 DOI: 10.1016/j.nec.2023.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2023]
Abstract
Overall stereoelectroencephalography (SEEG) has a favorable risk profile, patient tolerability, and superior investigative capability of individualized 3-dimensional seizure onset activity over subdural electrodes. Further, our recent surgical approach to safely enable multinuclear thalamic propagation mapping can only be performed with SEEG. For these reasons, SEEG has become the gold standard of phase II monitoring at our institution, and believe the ability to develop precision network-centric approaches to therapy will be critical to enhance our ability to care for medically refractory, and importantly, even complex multifocal, generalized, or surgically refractory epilepsy patients.
Collapse
Affiliation(s)
- Vivek P Buch
- Stanford University, 453 Quarry Road Room 245C, Palo Alto, CA 94304, USA.
| | - Josef Parvizi
- Stanford University, 213 Quarry Road MC 5957 Fl 2, Palo Alto, CA 94304, USA
| |
Collapse
|
12
|
Anderson W, Ponce FA, Kinsman MJ, Sani S, Hwang B, Ghinda D, Kogan M, Mahoney JM, Amin DB, Van Horn M, McGuckin JP, Razo-Castaneda D, Bucklen BS. Robotic-Assisted Navigation for Stereotactic Neurosurgery: A Cadaveric Investigation of Accuracy, Time, and Radiation. Oper Neurosurg (Hagerstown) 2023; 26:01787389-990000000-00991. [PMID: 38054727 PMCID: PMC11008650 DOI: 10.1227/ons.0000000000001024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 10/18/2023] [Indexed: 12/07/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Despite frequent use, stereotactic head frames require manual coordinate calculations and manual frame settings that are associated with human error. This study examines freestanding robot-assisted navigation (RAN) as a means to reduce the drawbacks of traditional cranial stereotaxy and improve targeting accuracy. METHODS Seven cadaveric human torsos with heads were tested with 8 anatomic coordinates selected for lead placement mirrored in each hemisphere. Right and left hemispheres of the brain were randomly assigned to either the traditional stereotactic arc-based (ARC) group or the RAN group. Both target accuracy and trajectory accuracy were measured. Procedural time and the radiation required for registration were also measured. RESULTS The accuracy of the RAN group was significantly greater than that of the ARC group in both target (1.2 ± 0.5 mm vs 1.7 ± 1.2 mm, P = .005) and trajectory (0.9 ± 0.6 mm vs 1.3 ± 0.9 mm, P = .004) measurements. Total procedural time was also significantly faster for the RAN group than for the ARC group (44.6 ± 7.7 minutes vs 86.0 ± 12.5 minutes, P < .001). The RAN group had significantly reduced time per electrode placement (2.9 ± 0.9 minutes vs 5.8 ± 2.0 minutes, P < .001) and significantly reduced radiation during registration (1.9 ± 1.1 mGy vs 76.2 ± 5.0 mGy, P < .001) compared with the ARC group. CONCLUSION In this cadaveric study, cranial leads were placed faster and with greater accuracy using RAN than those placed with conventional stereotactic arc-based technique. RAN also required significantly less radiation to register the specimen's coordinate system to the planned trajectories. Clinical testing should be performed to further investigate RAN for stereotactic cranial surgery.
Collapse
Affiliation(s)
- William Anderson
- Department of Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA
| | - Francisco A. Ponce
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Michael J. Kinsman
- Neurosurgery, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - Sepehr Sani
- Department of Neurosurgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Brian Hwang
- Department of Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA
- Current Affiliation: Orange County Neurosurgical Associates, Laguna Hills, California, USA
| | - Diana Ghinda
- Department of Neurosurgery, The Johns Hopkins Hospital, Baltimore, Maryland, USA
| | - Michael Kogan
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania, USA
| | - Jonathan M. Mahoney
- Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA
| | - Dhara B. Amin
- Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA
| | - Margaret Van Horn
- Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA
| | - Joshua P. McGuckin
- Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA
| | - Dominic Razo-Castaneda
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Brandon S. Bucklen
- Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, Pennsylvania, USA
| |
Collapse
|
13
|
Aung T, Mallela A, Ho J, Tang LW, Abou-Al-Shaar H, Gonzalez Martinez J. Challenging Cortical Explorations in Difficult-to-Localize Seizures: The Rationale and Usefulness of Perisylvian Paralimbic Explorations With Orthogonal Stereoelectroencephalography Depth Electrodes. Neurosurgery 2023:00006123-990000000-00982. [PMID: 38047640 DOI: 10.1227/neu.0000000000002787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 10/14/2023] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND AND OBJECTIVE Stereoelectroencephalography (SEEG) is an invasive monitoring method designed to define and localize the epileptogenic zone (EZ) and explore the putative network responsible for the electroclinical seizures using anatomo-functional-electroclinical correlations. When indicated by semiology in selected patients, exploration of both limbic and paralimbic (PL) regions is indispensable. However, the PL cortex is located in deep and highly vascularized areas in proximity to the anterior Sylvian fissure and middle cerebral artery branches. Thus, those explorations are considered surgically challenging because of the multilobar location and fear of hemorrhagic events. Here, we discuss and illustrate the rationale and SEEG methodology approach in usefulness of exploring the PL regions using standard orthogonal SEEG depth electrode trajectories with the Talariach reference system. METHODS We retrospectively studied PL exploration from a cohort of 71 consecutive SEEG procedures from Nov 2019 to Nov 2022 and identified 31 patients who underwent PL trajectories. RESULTS In 31 patients, there were 32 SEEG trajectories, and no major complications were observed. PL electrodes were consistently implanted in the C10/D10 coordinates of the Talariach reference coordinates. The most common confirmed EZ in our cohort was mesio-temporal (45%), followed by temporo-perisylvian regions (16%), ventromedial frontal (13%), and mesio-lateral temporal regions (13%). The PL contacts were involved in the EZ in 10 patients (32%). Of 31 patients, 25 underwent resective surgery, and 19 obtained Engel 1 outcome with a mean follow-up of 25 months (range 12-41 months) after surgery. CONCLUSION The orthogonal perisylvian PL trajectories are feasible and useful in sampling multiple PL regions with single-electrode trajectories. In patients with perisylvian seizures, sampling PL structures may contribute to an improved understanding of seizure propagation and the optimal anatomic demarcation of the EZs in this surgically challenging region.
Collapse
Affiliation(s)
- Thandar Aung
- University of Pittsburgh Comprehensive Epilepsy Center (UPCEC), Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Arka Mallela
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Jonathan Ho
- Department of Neurology, University of Pittsburgh Medical Center and University of Pittsburgh Medical School, Pittsburgh, Pennsylvania, USA
| | - Lilly W Tang
- Department of Neurology, University of Pittsburgh Medical Center and University of Pittsburgh Medical School, Pittsburgh, Pennsylvania, USA
| | - Hussam Abou-Al-Shaar
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Jorge Gonzalez Martinez
- University of Pittsburgh Comprehensive Epilepsy Center (UPCEC), Department of Neurology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
14
|
Srinvasan HL, Raslan A, Tambirajoo K, Selway R, Ashkan K, Hasegawa H. Neuromate ® robot-assisted ventricular catheter insertion. Br J Neurosurg 2023; 37:1689-1692. [PMID: 34187266 DOI: 10.1080/02688697.2021.1941762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Accepted: 06/07/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND AND IMPORTANCE Insertion of ventricular catheters into small ventricles may require image guidance. Several options exist, including ultrasound guidance, frameless, and frame-based stereotactic approaches. There is no literature on management options when conventional image guidance fails to cannulate the ventricle. The accuracy of the robotic arm is well established in functional and epilepsy surgery. We report the first case using the Neuromate® robot for the placement of a shunt ventricular catheter into the lateral ventricle after a failed attempt with a more commonly used frameless electromagnetic navigation system. CLINICAL PRESENTATION A 30-year-old man had twice previously undergone foramen magnum decompression for a Chiari 1 malformation. He subsequently developed a significant cervical syrinx with clinical deterioration and a decision was made to place a ventriculoperitoneal shunt. As the ventricles were small, frameless electromagnetic navigation was used but the ventricle could not be cannulated. The Neuromate® robot was subsequently used to place the ventricular catheter successfully. CONCLUSION Neuromate® robot-assisted ventricular catheter placement may be considered when difficulty is experienced with more commonly used image guidance techniques.
Collapse
Affiliation(s)
| | - Ahmed Raslan
- King's College Hospital, Neurosurgery, London, United Kingdom of Great Britain and Northern Ireland
| | - Kantharuby Tambirajoo
- King's College Hospital, Neurosurgery, London, United Kingdom of Great Britain and Northern Ireland
| | - Richard Selway
- King's College Hospital, Neurosurgery, London, United Kingdom of Great Britain and Northern Ireland
| | - Keyoumars Ashkan
- King's College Hospital, Neurosurgery, London, United Kingdom of Great Britain and Northern Ireland
| | - Harutomo Hasegawa
- King's College Hospital, Neurosurgery, London, United Kingdom of Great Britain and Northern Ireland
| |
Collapse
|
15
|
Breault MS, Sacré P, Fitzgerald ZB, Gale JT, Cullen KE, González-Martínez JA, Sarma SV. Internal states as a source of subject-dependent movement variability are represented by large-scale brain networks. Nat Commun 2023; 14:7837. [PMID: 38030611 PMCID: PMC10687170 DOI: 10.1038/s41467-023-43257-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Accepted: 11/03/2023] [Indexed: 12/01/2023] Open
Abstract
Humans' ability to adapt and learn relies on reflecting on past performance. These experiences form latent representations called internal states that induce movement variability that improves how we interact with our environment. Our study uncovered temporal dynamics and neural substrates of two states from ten subjects implanted with intracranial depth electrodes while they performed a goal-directed motor task with physical perturbations. We identified two internal states using state-space models: one tracking past errors and the other past perturbations. These states influenced reaction times and speed errors, revealing how subjects strategize from trial history. Using local field potentials from over 100 brain regions, we found large-scale brain networks such as the dorsal attention and default mode network modulate visuospatial attention based on recent performance and environmental feedback. Notably, these networks were more prominent in higher-performing subjects, emphasizing their role in improving motor performance by regulating movement variability through internal states.
Collapse
Affiliation(s)
- Macauley Smith Breault
- Picower Institute for Learning and Memory, Massachusetts Institute of Technology, Cambridge, MA, USA.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
| | - Pierre Sacré
- Department of Electrical Engineering and Computer Science, School of Engineering, University of Liège, Liège, Belgium
| | - Zachary B Fitzgerald
- Department of Neurology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | | | - Kathleen E Cullen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | | | - Sridevi V Sarma
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
16
|
Sheth SA, Shofty B, Allawala A, Xiao J, Adkinson JA, Mathura RK, Pirtle V, Myers J, Oswalt D, Provenza NR, Giridharan N, Noecker AM, Banks GP, Gadot R, Najera RA, Anand A, Devara E, Dang H, Bartoli E, Watrous A, Cohn J, Borton D, Mathew SJ, McIntyre CC, Goodman W, Bijanki K, Pouratian N. Stereo-EEG-guided network modulation for psychiatric disorders: Surgical considerations. Brain Stimul 2023; 16:1792-1798. [PMID: 38135358 PMCID: PMC10787578 DOI: 10.1016/j.brs.2023.07.057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/30/2023] [Accepted: 07/30/2023] [Indexed: 12/24/2023] Open
Abstract
BACKGROUND Deep brain stimulation (DBS) and other neuromodulatory techniques are being increasingly utilized to treat refractory neurologic and psychiatric disorders. OBJECTIVE /Hypothesis: To better understand the circuit-level pathophysiology of treatment-resistant depression (TRD) and treat the network-level dysfunction inherent to this challenging disorder, we adopted an approach of inpatient intracranial monitoring borrowed from the epilepsy surgery field. METHODS We implanted 3 patients with 4 DBS leads (bilateral pair in both the ventral capsule/ventral striatum and subcallosal cingulate) and 10 stereo-electroencephalography (sEEG) electrodes targeting depression-relevant network regions. For surgical planning, we used an interactive, holographic visualization platform to appreciate the 3D anatomy and connectivity. In the initial surgery, we placed the DBS leads and sEEG electrodes using robotic stereotaxy. Subjects were then admitted to an inpatient monitoring unit for depression-specific neurophysiological assessments. Following these investigations, subjects returned to the OR to remove the sEEG electrodes and internalize the DBS leads to implanted pulse generators. RESULTS Intraoperative testing revealed positive valence responses in all 3 subjects that helped verify targeting. Given the importance of the network-based hypotheses we were testing, we required accurate adherence to the surgical plan (to engage DBS and sEEG targets) and stability of DBS lead rotational position (to ensure that stimulation field estimates of the directional leads used during inpatient monitoring were relevant chronically), both of which we confirmed (mean radial error 1.2±0.9 mm; mean rotation 3.6±2.6°). CONCLUSION This novel hybrid sEEG-DBS approach allows detailed study of the neurophysiological substrates of complex neuropsychiatric disorders.
Collapse
Affiliation(s)
- Sameer A Sheth
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA.
| | - Ben Shofty
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Anusha Allawala
- Department of Engineering, Brown University, Providence, RI, USA
| | - Jiayang Xiao
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Joshua A Adkinson
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Raissa K Mathura
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Victoria Pirtle
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - John Myers
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Denise Oswalt
- Department of Neurosurgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Nicole R Provenza
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Nisha Giridharan
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Angela M Noecker
- Departments of Biomedical Engineering and Neurosurgery, Duke University, Durham, NC, USA
| | - Garrett P Banks
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Ron Gadot
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Ricardo A Najera
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Adrish Anand
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Ethan Devara
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Huy Dang
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Eleonora Bartoli
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Andrew Watrous
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Jeffrey Cohn
- Department of Psychology, University of Pittsburgh, Pittsburgh, PA, USA
| | - David Borton
- Department of Engineering, Brown University, Providence, RI, USA
| | - Sanjay J Mathew
- Department of Psychiatry, Baylor College of Medicine, Houston, TX, USA
| | | | - Wayne Goodman
- Department of Psychiatry, Baylor College of Medicine, Houston, TX, USA
| | - Kelly Bijanki
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Nader Pouratian
- Department of Neurological Surgery, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
17
|
Agashe S, Brinkmann BH, Cox BC, Wong-Kisiel L, Van Gompel JJ, Marsh RW, Miller KJ, Krecke KN, Britton JW. Implications of intracranial hemorrhage associated with stereo-EEG. Clin Neurophysiol 2023; 155:86-93. [PMID: 37806180 DOI: 10.1016/j.clinph.2023.08.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 07/27/2023] [Accepted: 08/18/2023] [Indexed: 10/10/2023]
Abstract
OBJECTIVE Intracranial hemorrhage (ICH) is a known complication during stereo-electroencephalography (sEEG) however true rates remain unknown. We provide a comprehensive review of ICH during sEEG regardless of clinical symptoms. Secondly, we analyzed sEEG recordings to identify electrographic correlates of ICH. METHODS This is a retrospective study of patients undergoing sEEG between January 2016 and April 2022 at the Mayo Clinic in Rochester. We reviewed medical records and imaging studies to identify ICH. We analyzed ICH by type, electrode trajectories, timing, sEEG findings and outcomes. RESULTS There were a total of 201 sEEG implants, of which 23 (11%) cases or 0.9% electrodes implanted had evidence of ICH. The majority of affected patients (82%) were either asymptomatic or had mild clinical neurological manifestations. In 90% of patients who proceeded with surgical treatments, outcomes were favorable. The most common sEEG finding in contacts in proximity of ICH was either focal slowing with interictal discharges or focal electrographic seizures. CONCLUSIONS ICH associated with sEEG is likely under-reported in literature. We present electroencephalographic correlates of ICH that may aid identification of ICH in the course of performing sEEG monitoring. SIGNIFICANCE Our data provides clinically relevant information on potential risks and outcomes of ICH. Furthermore, our findings aid identification of ICH during sEEG.
Collapse
Affiliation(s)
- Shruti Agashe
- Department of Neurology, Mayo Clinic, Rochester, MN, USA.
| | | | - Benjamin C Cox
- Department of Neurology, Mayo Clinic, Rochester, MN, USA
| | | | | | | | - Kai J Miller
- Department of Neurosurgery, Mayo Clinic, Rochester, MN, USA
| | - Karl N Krecke
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
18
|
Karas PJ, Lee JE, Frank TS, Morden FT, Shaltoni H, Kan P. Robotic-guided direct transtemporal embolization of an indirect carotid cavernous fistula. J Neurointerv Surg 2023; 15:1122-1123. [PMID: 36627196 DOI: 10.1136/jnis-2022-019868] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 12/28/2022] [Indexed: 01/11/2023]
Abstract
A middle-aged patient presented with right-sided chemosis, exophthalmos, and progressive visual loss. Digital subtraction angiography revealed a type D carotid-cavernous fistula (CCF). Transarterial embolization through the internal maxillary artery was unsuccessful, and there was no venous access to the CCF. A robotic-guided direct transtemporal embolization of the CCF with Onyx was performed, resulting in successful fistula obliteration and symptom resolution. This is the first reported case of a robotic-guided direct transcranial CCF embolization. We include a technical video that demonstrates this procedure (Supplemental File 1).
Collapse
Affiliation(s)
- Patrick J Karas
- Department of Neurosurgery, University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Jae Eun Lee
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | - Thomas S Frank
- Department of Neurosurgery, University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| | - Frances Tiffany Morden
- Department of Neurosurgery, University of Hawai'i at Mānoa John A Burns School of Medicine, Honolulu, Hawaii, USA
| | - Hashem Shaltoni
- Department of Neurology, University of Texas Medical Branch, Galveston, Texas, USA
| | - Peter Kan
- Department of Neurosurgery, University of Texas Medical Branch at Galveston, Galveston, Texas, USA
| |
Collapse
|
19
|
Li P, Zhou Y, Zhang Q, Yang Y, Wang M, Zhu R, Li H, Gu S, Zhao R. Frameless robot-assisted stereoelectroencephalography-guided radiofrequency: methodology, results, complications and stereotactic application accuracy in pediatric hypothalamic hamartomas. Front Neurol 2023; 14:1259171. [PMID: 37928157 PMCID: PMC10621047 DOI: 10.3389/fneur.2023.1259171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 10/09/2023] [Indexed: 11/07/2023] Open
Abstract
Objective We aimed to investigate the methodology, results, complications and stereotactic application accuracy of electrode implantation and its explanatory variables in stereoelectroencephalography-guided radiofrequency thermocoagulation (SEEG-RFTC) for pediatric hypothalamic hamartoma. Methods Children with hypothalamic hamartoma who underwent robot-assisted SEEG-RFTC between December 2017 and November 2021 were retrospectively analyzed. The methodology, seizure outcome, complications, in vivo accuracy of electrode implantation and its explanatory variables were analyzed. Results A total of 161 electrodes were implanted in 28 patients with 30 surgeries. Nine electrodes not following the planned trajectories due to intraoperative replanning were excluded, and the entry point and target point errors of 152 electrodes were statistically analyzed. The median entry point error was 0.87 mm (interquartile range, 0.50-1.41 mm), and the median target point error was 2.74 mm (interquartile range, 2.01-3.63 mm). Multifactor analysis showed that whether the electrode was bent (b = 2.16, p < 0.001), the length of the intracranial electrode (b = 0.02, p = 0.049), and the entry point error (b = 0.337, p = 0.017) had statistically significant effects on the target error. During follow-up (mean duration 31 months), 27 of 30 (90%) procedures were seizure-free. The implantation-related complication rate was 2.6% (4/152), and the major complication rate in all procedures was 6.7% (2/30). Conclusion Robot-assisted SEEG-RFTC is a safe, effective and accurate procedure for pediatric hypothalamic hamartoma. Explanatory variables significantly associated with the target point localization error at multivariate analysis include whether the intracranial electrode is bent, the intracranial electrode length and the entry point error.
Collapse
Affiliation(s)
- Ping Li
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
| | - Yuanfeng Zhou
- Department of Neurology, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Qin Zhang
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
| | - Yuantao Yang
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
| | - Min Wang
- Department of Neurosurgery, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Renqing Zhu
- Department of Neurosurgery, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Hao Li
- Department of Neurosurgery, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Shuo Gu
- Department of Neurosurgery, The First Affiliated Hospital of Hainan Medical University, Haikou, China
| | - Rui Zhao
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
- Department of Neurosurgery, Children’s Hospital of Shanghai, Shanghai, China
| |
Collapse
|
20
|
Vasconcellos FDN, Almeida T, Müller Fiedler A, Fountain H, Santos Piedade G, Monaco BA, Jagid J, Cordeiro JG. Robotic-Assisted Stereoelectroencephalography: A Systematic Review and Meta-Analysis of Safety, Outcomes, and Precision in Refractory Epilepsy Patients. Cureus 2023; 15:e47675. [PMID: 38021558 PMCID: PMC10672406 DOI: 10.7759/cureus.47675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/25/2023] [Indexed: 12/01/2023] Open
Abstract
Robotic assistance in stereoelectroencephalography (SEEG) holds promising potential for enhancing accuracy, efficiency, and safety during electrode placement and surgical procedures. This systematic review and meta-analysis, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and International Prospective Register of Systematic Reviews (PROSPERO) registration, delves into the latest advancements and implications of robotic systems in SEEG, while meticulously evaluating outcomes and safety measures. Among 855 patients suffering from medication-refractory epilepsy who underwent SEEG in 29 studies, averaging 24.6 years in age, the most prevalent robots employed were robotic surgical assistant (ROSA) (450 patients), Neuromate (207), Sinovation (140), and ISys1 (58). A total of 8,184 electrodes were successfully implanted, with an average operative time of 157.2 minutes per procedure and 15.1 minutes per electrode, resulting in an overall mean operative time of 157.7 minutes across all studies. Notably, the mean target point error (TPE) stood at 2.13 mm, the mean entry point error (EPE) at 1.48 mm, and postoperative complications occurred in 7.69% of robotically assisted (RA) SEEG cases (60), with 85% of these complications being asymptomatic. This comprehensive analysis underscores the safety and efficacy of RA-SEEG in patients with medication-refractory epilepsy, characterized by low complication rates, reduced operative time, and precise electrode placement, supporting its widespread adoption in clinical practice, with no discernible differences noted among the various robotic systems.
Collapse
Affiliation(s)
| | - Timoteo Almeida
- Department of Neurosurgery, University of Miami, Miami, USA
- Department of Radiation Oncology, University of Miami, Miami, USA
| | | | - Hayes Fountain
- Department of Neurosurgery, University of Miami, Miami, USA
| | | | - Bernardo A Monaco
- Department of Neurological Surgery, University of Miami, Miami, USA
- Department of Neurological Surgery, CDF (Clinica de Dor e Funcional), Sao Paulo, BRA
- Department of Neurological Surgery, University of Sao Paulo, Sao Paulo, BRA
| | - Jonathan Jagid
- Department of Neurological Surgery, University of Miami, Miami, USA
| | | |
Collapse
|
21
|
Chen MI, Lee D, Wong BJ. Innovations in diagnostic and treatment options for pediatric epilepsy and their anesthetic implications. Curr Opin Anaesthesiol 2023; 36:485-490. [PMID: 37552014 DOI: 10.1097/aco.0000000000001303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
PURPOSE OF REVIEW To provide an overview of anesthetic techniques for innovative diagnostic and therapeutic epilepsy procedures performed on pediatric patients. RECENT FINDINGS Recent studies have been published on the anesthetic consideration for functional MRI, robotic-assisted stereoelectroencephalography, high-intensity focused ultrasound, and magnetoencephalography. These articles describe the anesthesia management, risks, and outcome for these procedures. SUMMARY The number of diagnostic and treatment options being used for the management of pediatric epilepsy has increased significantly. In the past few years, a handful of articles have been published, which describe the anesthetic considerations for these procedures. These studies are helpful to anesthesiologists who are planning an upcoming anesthetic or who are developing a 'best practice' model for their institution. Because unlike other diagnostic studies, failure to understand what effects anesthetics have on the brain, may negate the utility of the study. Although these new findings can be used to provide some anesthesia practice recommendations for epilepsy procedures in which the best management is still unclear, additional high-quality studies are needed.
Collapse
Affiliation(s)
- Michael I Chen
- Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford
| | - David Lee
- Loma Linda University School of Medicine, Loma Linda, California, USA
| | - Becky J Wong
- Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford
| |
Collapse
|
22
|
Xiao J, Provenza NR, Asfouri J, Myers J, Mathura RK, Metzger B, Adkinson JA, Allawala AB, Pirtle V, Oswalt D, Shofty B, Robinson ME, Mathew SJ, Goodman WK, Pouratian N, Schrater PR, Patel AB, Tolias AS, Bijanki KR, Pitkow X, Sheth SA. Decoding Depression Severity From Intracranial Neural Activity. Biol Psychiatry 2023; 94:445-453. [PMID: 36736418 PMCID: PMC10394110 DOI: 10.1016/j.biopsych.2023.01.020] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2022] [Revised: 01/09/2023] [Accepted: 01/25/2023] [Indexed: 02/05/2023]
Abstract
BACKGROUND Disorders of mood and cognition are prevalent, disabling, and notoriously difficult to treat. Fueling this challenge in treatment is a significant gap in our understanding of their neurophysiological basis. METHODS We recorded high-density neural activity from intracranial electrodes implanted in depression-relevant prefrontal cortical regions in 3 human subjects with severe depression. Neural recordings were labeled with depression severity scores across a wide dynamic range using an adaptive assessment that allowed sampling with a temporal frequency greater than that possible with typical rating scales. We modeled these data using regularized regression techniques with region selection to decode depression severity from the prefrontal recordings. RESULTS Across prefrontal regions, we found that reduced depression severity is associated with decreased low-frequency neural activity and increased high-frequency activity. When constraining our model to decode using a single region, spectral changes in the anterior cingulate cortex best predicted depression severity in all 3 subjects. Relaxing this constraint revealed unique, individual-specific sets of spatiospectral features predictive of symptom severity, reflecting the heterogeneous nature of depression. CONCLUSIONS The ability to decode depression severity from neural activity increases our fundamental understanding of how depression manifests in the human brain and provides a target neural signature for personalized neuromodulation therapies.
Collapse
Affiliation(s)
- Jiayang Xiao
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas; Department of Neuroscience, Baylor College of Medicine, Houston, Texas
| | - Nicole R Provenza
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Joseph Asfouri
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas
| | - John Myers
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Raissa K Mathura
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Brian Metzger
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Joshua A Adkinson
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | | | - Victoria Pirtle
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Denise Oswalt
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Ben Shofty
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Meghan E Robinson
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Sanjay J Mathew
- Department of Psychiatry, Baylor College of Medicine, Houston, Texas
| | - Wayne K Goodman
- Department of Psychiatry, Baylor College of Medicine, Houston, Texas
| | - Nader Pouratian
- Department of Neurological Surgery, UT Southwestern Medical Center, Dallas, Texas
| | - Paul R Schrater
- Department of Computer Science and Engineering, University of Minnesota, Minneapolis, Minnesota; Department of Psychology, University of Minnesota, Minneapolis, Minnesota
| | - Ankit B Patel
- Department of Neuroscience, Baylor College of Medicine, Houston, Texas; Department of Electrical and Computer Engineering, Rice University, Houston, Texas; Center for Neuroscience and Artificial Intelligence, Baylor College of Medicine, Houston, Texas
| | - Andreas S Tolias
- Department of Neuroscience, Baylor College of Medicine, Houston, Texas; Department of Electrical and Computer Engineering, Rice University, Houston, Texas; Center for Neuroscience and Artificial Intelligence, Baylor College of Medicine, Houston, Texas
| | - Kelly R Bijanki
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas
| | - Xaq Pitkow
- Department of Neuroscience, Baylor College of Medicine, Houston, Texas; Department of Electrical and Computer Engineering, Rice University, Houston, Texas; Center for Neuroscience and Artificial Intelligence, Baylor College of Medicine, Houston, Texas
| | - Sameer A Sheth
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas.
| |
Collapse
|
23
|
Gorbachuk M, Machetanz K, Weinbrenner E, Grimm F, Wuttke TV, Wang S, Ethofer S, Tatagiba M, Rona S, Honegger J, Naros G. Robot-assisted stereoencephalography vs subdural electrodes in the evaluation of temporal lobe epilepsy. Epilepsia Open 2023; 8:888-897. [PMID: 37149851 PMCID: PMC10472365 DOI: 10.1002/epi4.12756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 04/30/2023] [Indexed: 05/09/2023] Open
Abstract
OBJECTIVE Invasive video-electroencephalography (iVEEG) is the gold standard for evaluation of refractory temporal lobe epilepsy before second stage resective surgery (SSRS). Traditionally, the presumed seizure onset zone (SOZ) has been covered with subdural electrodes (SDE), a very invasive procedure prone to complications. Temporal stereoelectroencephalography (SEEG) with conventional frame-based stereotaxy is time-consuming and impeded by the geometry of the frame. The introduction of robotic assistance promised a simplification of temporal SEEG implantation. However, the efficacy of temporal SEEG in iVEEG remains unclear. The aim of this study was therefore to describe the efficiency and efficacy of SEEG in iVEEG of temporal lobe epilepsy. METHODS This retrospective study enrolled 60 consecutive patients with medically intractable epilepsy who underwent iVEEG of a potential temporal SOZ by SDE (n = 40) or SEEG (n = 20). Surgical time efficiency was analyzed by the skin-to-skin time (STS) and the total procedure time (TPT) and compared between groups (SDE vs SEEG). Surgical risk was depicted by the 90-day complication rate. Temporal SOZ were treated by SSRS. Favorable outcome (Engel°1) was assessed after 1 year of follow-up. RESULTS Robot-assisted SEEG significantly reduced the duration of surgery (STS and TPT) compared to SDE implantations. There was no significant difference in complication rates. Notably, all surgical revisions in this study were attributed to SDE. Unilateral temporal SOZ was detected in 34/60 cases. Of the 34 patients, 30 underwent second stage SSRS. Both SDE and SEEG had a good predictive value for the outcome of temporal SSRS with no significant group difference. SIGNIFICANCE Robot-assisted SEEG improves the accessibility of the temporal lobe for iVEEG by increasing surgical time efficiency and by simplifying trajectory selection without losing its predictive value for SSRS.
Collapse
Affiliation(s)
- Mykola Gorbachuk
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Kathrin Machetanz
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Eliane Weinbrenner
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Florian Grimm
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Thomas V. Wuttke
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Sophie Wang
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Silke Ethofer
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Marcos Tatagiba
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Sabine Rona
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Jürgen Honegger
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Georgios Naros
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| |
Collapse
|
24
|
Williams A, Ordaz JD, Budnick H, Desai VR, Tailor Bmbch J, Raskin JS. Accuracy of Depth Electrodes is Not Time-Dependent in Robot-Assisted Stereoelectroencephalography in a Pediatric Population. Oper Neurosurg (Hagerstown) 2023; 25:269-277. [PMID: 37219595 DOI: 10.1227/ons.0000000000000764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 03/21/2023] [Indexed: 05/24/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Robot-assisted stereoelectroencephalography (sEEG) is steadily supplanting traditional frameless and frame-based modalities for minimally invasive depth electrode placement in epilepsy workup. Accuracy rates similar to gold-standard frame-based techniques have been achieved, with improved operative efficiency. Limitations in cranial fixation and placement of trajectories in pediatric patients are believed to contribute to a time-dependent accumulation of stereotactic error. Thus, we aim to study the impact of time as a marker of cumulative stereotactic error during robotic sEEG. METHODS All patients between October 2018 and June 2022 who underwent robotic sEEG were included. Radial errors at entry and target points as well as depth and Euclidean distance errors were collected for each electrode, excluding those with errors over 10 mm. Target point errors were standardized by planned trajectory length. ANOVA and error rates over time were analyzed using GraphPad Prism 9. RESULTS Forty-four patients met inclusion criteria for a total of 539 trajectories. Number of electrodes placed ranged from 6 to 22. Average root mean squared error was 0.45 ± 0.12 mm. Average entry, target, depth, and Euclidean distance errors were 1.12 ± 0.41 mm, 1.46 ± 0.44 mm, -1.06 ± 1.43 mm, and 3.01 ± 0.71 mm, respectively. There was no significant increased error with each sequential electrode placed (entry error P -value = .54, target error P -value = .13, depth error P -value = .22, Euclidean distance P -value = .27). CONCLUSION No decremental accuracy over time was observed. This may be secondary to our workflow which prioritizes oblique and longer trajectories first and then into less error-prone trajectories. Further study on the effect of level of training may reveal a novel difference in error rates.
Collapse
Affiliation(s)
- Ari Williams
- Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Josue D Ordaz
- Department of Neurological Surgery, Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Hailey Budnick
- Department of Neurological Surgery, Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Virendra R Desai
- Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Jignesh Tailor Bmbch
- Department of Neurological Surgery, Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Jeffrey S Raskin
- Department of Neurosurgery, Section of Pediatric Neurosurgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
25
|
Yindeedej V, Uda T, Kawashima T, Koh S, Tanoue Y, Kojima Y, Goto T. Electrode Tip Shift During the Stereotactic Electroencephalography Evaluation Period with Boltless Suture Fixation. World Neurosurg 2023; 175:e1210-e1219. [PMID: 37427700 DOI: 10.1016/j.wneu.2023.04.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 04/24/2023] [Indexed: 07/11/2023]
Abstract
BACKGROUND Electrodes for stereotactic electroencephalography (SEEG) are typically fixed to the skull with anchor bolts. When anchor bolts are unavailable, electrodes have to be fixed using other methods, carrying the possibility of electrode shift. This study, therefore, evaluated the characteristics of electrode tip shift during SEEG monitoring in patients with electrodes fixed using the suture technique. METHODS We retrospectively included patients who underwent SEEG implantation with suture fixation and evaluated the tip shift distance (TSD) of electrodes. Possible influences evaluated included: 1) implantation period, 2) lobe of entry, 3) unilateral or bilateral implantation, 4) electrode length, 5) skull thickness, and 6) scalp thickness difference. RESULTS A total of 50 electrodes in 7 patients were evaluated. TSD was 1.4 ± 2.0 mm (mean ± standard deviation). Implantation period was 8.1 ± 2.2 days. Entry lobe was frontal for 28 electrodes and temporal for 22 electrodes. Implantation was bilateral for 25 electrodes and unilateral for 25 electrodes. Electrode length was 45.4 ± 14.3 mm. Skull thickness was 6.0 ± 3.7 mm. Scalp thickness difference was -1.5 ± 2.1 mm, which was found greater in temporal lobe entry compared with frontal lobe entry. According to univariate analyses, neither implantation period nor electrode length correlated with TSD. Multivariate regression analysis showed that only greater scalp thickness difference correlated significantly with greater TSD (P = 0.0018). CONCLUSIONS Greater scalp thickness difference correlated with greater TSD. Surgeons need to consider the degree of scalp thickness difference and electrode shift when using suture fixation, especially with temporal lobe entry.
Collapse
Affiliation(s)
- Vich Yindeedej
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan; Division of Neurosurgery, Department of Surgery, Thammasat University Hospital, Faculty of Medicine, Thammasat University, Pathumthani, Thailand
| | - Takehiro Uda
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan.
| | - Toshiyuki Kawashima
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Saya Koh
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Yuta Tanoue
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Yuichiro Kojima
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Takeo Goto
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
26
|
Ooi QY, Qin X, Yuan Y, Zhang X, Yao Y, Hao H, Li L. Alteration of Excitation/Inhibition Imbalance in the Hippocampus and Amygdala of Drug-Resistant Epilepsy Patients Treated with Acute Vagus Nerve Stimulation. Brain Sci 2023; 13:976. [PMID: 37508908 PMCID: PMC10377456 DOI: 10.3390/brainsci13070976] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/09/2023] [Accepted: 06/16/2023] [Indexed: 07/30/2023] Open
Abstract
An imbalance between excitation (E) and inhibition (I) in the brain has been identified as a key pathophysiology of epilepsy over the years. The hippocampus and amygdala in the limbic system play a crucial role in the initiation and conduction of epileptic seizures and are often referred to as the transfer station and amplifier of seizure activities. Existing animal and imaging studies reveal that the hippocampus and amygdala, which are significant parts of the vagal afferent network, can be modulated in order to generate an antiepileptic effect. Using stereo-electroencephalography (SEEG) data, we examined the E/I imbalance in the hippocampus and amygdala of ten drug-resistant epilepsy children treated with acute vagus nerve stimulation (VNS) by estimating the 1/f power slope of hippocampal and amygdala signals in the range of 1-80 Hz. While the change in the 1/f power slope from VNS-BASE varied between different stimulation amplitudes and brain regions, it was more prominent in the hippocampal region. In the hippocampal region, we found a flatter 1/f power slope during VNS-ON in patients with good responsiveness to VNS under the optimal stimulation amplitude, indicating that the E/I imbalance in the region was improved. There was no obvious change in 1/f power slope for VNS poor responders. For VNS non-responders, the 1/f power slope slightly increased when the stimulation was applied. Overall, this study implies that the regulation of E/I imbalance in the epileptic brain, especially in the hippocampal region, may be an acute intracranial effect of VNS.
Collapse
Affiliation(s)
- Qian Yi Ooi
- National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing 100084, China
| | - Xiaoya Qin
- National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing 100084, China
- Precision Medicine and Healthcare Research Center, Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518071, China
| | - Yuan Yuan
- National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing 100084, China
- Precision Medicine and Healthcare Research Center, Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518071, China
| | - Xiaobin Zhang
- Department of Functional Neurosurgery, Xiamen Humanity Hospital, Fujian Medical University, Fuzhou 350005, China
| | - Yi Yao
- Department of Functional Neurosurgery, Xiamen Humanity Hospital, Fujian Medical University, Fuzhou 350005, China
- Surgery Division, Epilepsy Center, Shenzhen Children's Hospital, Shenzhen 518038, China
| | - Hongwei Hao
- National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing 100084, China
| | - Luming Li
- National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing 100084, China
- Precision Medicine and Healthcare Research Center, Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518071, China
- IDG/McGovern Institute for Brain Research, Tsinghua University, Beijing 100084, China
| |
Collapse
|
27
|
Sharma N, Mallela AN, Abou-Al-Shaar H, Aung T, Gonzalez-Martinez J. Trans-Interhemispheric Stereoelectroencephalography Depth Electrode Placement for Mesial Frontal Lobe Explorations in Medically Refractory Epilepsy: A Technical Note and Case Series. Oper Neurosurg (Hagerstown) 2023; 24:582-589. [PMID: 36786750 DOI: 10.1227/ons.0000000000000631] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Accepted: 11/18/2022] [Indexed: 02/15/2023] Open
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) is an established and safe methodology for extra-operative invasive monitoring in patients with medical refractory epilepsy. SEEG has several advantages such as the ability to record deep cortical structures, mapping the epileptogenic zone in a three-dimensional manner, and analyze bihemispheric regions without the need for bilateral craniotomies. In patients with bilateral hemispheric hypotheses, especially the mesial surface of frontal lobes, bilateral lead placement is compulsory to further define and localize the epileptogenic zone. In this particular cohort of patients, bilateral monitoring may be accomplished from a single entry point using trans-interhemispheric placement of the electrodes. The use of trans-interhemispheric monitoring offers several advantages including sparing the need for additional leads. OBJECTIVE To test the hypothesis that, given the lack of the falx as a limiting structure in the ventral and mesial frontal lobe regions, trans-interhemispheric SEEG placement is feasible and a potential benefit for the SEEG method. METHODS We report on 6 patients who underwent bilateral monitoring using trans-interhemispheric SEEG lead placement and discuss the operative technique. RESULTS Six patients underwent trans-interhemispheric monitoring, with a median of 3 leads per patient (19 total). Trajectory error was minimal (<0.3 mm), and operating room time was comparable with that in previous reports. All leads were placed without adverse events, mislocalization, electrode hemorrhages, or any other complications. All patients had successful localization of the epileptogenic zone. CONCLUSION Trans-interhemispheric SEEG to monitor the mesial wall of frontal lobe regions is technically feasible. No adverse events were observed, suggesting a favorable safety profile.
Collapse
Affiliation(s)
- Nikhil Sharma
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Arka N Mallela
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Hussam Abou-Al-Shaar
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Thandar Aung
- Department of Neurology and Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Jorge Gonzalez-Martinez
- Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
- Department of Neurology and Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
28
|
Lee AT, Nichols NM, Speidel BA, Fan JM, Cajigas I, Knowlton RC, Chang EF. Modern intracranial electroencephalography for epilepsy localization with combined subdural grid and depth electrodes with low and improved hemorrhagic complication rates. J Neurosurg 2023; 138:821-827. [PMID: 35901681 DOI: 10.3171/2022.5.jns221118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 05/19/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Recent trends have moved from subdural grid electrocorticography (ECoG) recordings toward stereo-electroencephalography (SEEG) depth electrodes for intracranial localization of seizures, in part because of perceived morbidity from subdural grid and strip electrodes. For invasive epilepsy monitoring, the authors describe the outcomes of a hybrid approach, whereby patients receive a combination of subdural grids, strips, and frameless stereotactic depth electrode implantations through a craniotomy. Evolution of surgical techniques was employed to reduce complications. In this study, the authors review the surgical hemorrhage and functional outcomes of this hybrid approach. METHODS A retrospective review was performed of consecutive patients who underwent hybrid implantation from July 2012 to May 2022 at an academic epilepsy center by a single surgeon. Outcomes included hemorrhagic and nonhemorrhagic complications, neurological deficits, length of monitoring, and number of electrodes. RESULTS A total of 137 consecutive procedures were performed; 113 procedures included both subdural and depth electrodes. The number of depth electrodes and electrode contacts did not increase the risk of hemorrhage. A mean of 1.9 ± 0.8 grid, 4.9 ± 2.1 strip, and 3.0 ± 1.9 depth electrodes were implanted, for a mean of 125.1 ± 32 electrode contacts per patient. The overall incidence of hematomas over the study period was 5.1% (7 patients) and decreased significantly with experience and the introduction of new surgical techniques. The incidence of hematomas in the last 4 years of the study period was 0% (55 patients). Symptomatic hematomas were all delayed and extra-axial. These patients required surgical evacuation, and there were no cases of hematoma recurrence. All neurological deficits related to hematomas were temporary and were resolved at hospital discharge. There were 2 nonhemorrhagic complications. The mean duration of monitoring was 7.3 ± 3.2 days. Seizures were localized in 95% of patients, with 77% of patients eventually undergoing resection and 17% undergoing responsive neurostimulation device implantation. CONCLUSIONS In the authors' institutional experience, craniotomy-based subdural and depth electrode implantation was associated with low hemorrhage rates and no permanent morbidity. The rate of hemorrhage can be nearly eliminated with surgical experience and specific techniques. The decision to use subdural electrodes or SEEG should be tailored to the patient's unique pathology and surgeon experience.
Collapse
Affiliation(s)
| | | | | | - Joline M Fan
- 2Neurology, University of California, San Francisco, California
| | | | | | | |
Collapse
|
29
|
Ross MN, Larson EW, Shahin MN, Yaghi NK, Mazur-Hart DJ, Mitchell A, Mulcahy F, Ernst LD, Collins KL, Selden NR, Raslan AM. A Method of Intraoperative Registration Verification to Prevent Accuracy Errors in Robot-Assisted Stereotactic Electroencephalography Electrode Placement. World Neurosurg 2023; 171:1-4. [PMID: 36563849 DOI: 10.1016/j.wneu.2022.12.075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 12/15/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND Robotic-assisted stereotactic electroencephalography (sEEG) electrode placement is increasingly common at specialized epilepsy centers. High accuracy and low complication rates are essential to realizing the benefits of sEEG surgery. The aim of this study was to describe for the first time in the literature a method for a stereotactic registration checkpoint to verify intraoperative accuracy during robotic-assisted sEEG and to report our institutional experience with this technique. METHODS All cases performed with this technique since the adoption of robotic-assisted sEEG at our institution were retrospectively reviewed. RESULTS In 4 of 111 consecutive sEEG operations, use of the checkpoint detected an intraoperative registration error, which was addressed before completion of sEEG electrode placement. CONCLUSIONS The use of a registration checkpoint in robotic-assisted sEEG surgery is a simple technique that can prevent electrode misplacement and improve the safety profile of this procedure.
Collapse
Affiliation(s)
- Miner N Ross
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA.
| | - Erik W Larson
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Maryam N Shahin
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Nasser K Yaghi
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - David J Mazur-Hart
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Ann Mitchell
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Faye Mulcahy
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Lia D Ernst
- Department of Neurology, Oregon Health & Science University, Portland, Oregon, USA
| | - Kelly L Collins
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Nathan R Selden
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| | - Ahmed M Raslan
- Department of Neurological Surgery, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
30
|
Hines K, Matias CM, Leibold A, Sharan A, Wu C. Accuracy and efficiency using frameless transient fiducial registration in stereoelectroencephalography and deep brain stimulation. J Neurosurg 2023; 138:299-305. [PMID: 35901701 DOI: 10.3171/2022.5.jns22804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/19/2022] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Stereotactic surgical methods continue to advance technologically. Frameless transient fiducial registration (FTFR) systems have been developed and avoid the need to move or position a patient in a frame after already receiving registration imaging. One such system, Neurolocate, has recently become available as a robotic attachment for the Neuromate stereotactic robot. This study is the largest in the literature to evaluate the accuracy of frameless registration using Neurolocate versus frame-based registration (FBR) methods in both deep brain stimulation (DBS) and stereoelectroencephalography (SEEG). Additionally, the authors sought to reevaluate factors affecting accuracy in both procedures. METHODS This study was a retrospective chart and imaging review of 88 consecutive procedures (involving 621 electrodes) implanting either DBS or SEEG at the authors' institution over a 5-year period from March 2015 to March 2020. Registration duration, radial target entry point, and Euclidean target implantation accuracies, as well as factors affecting accuracy, were recorded for each patient. RESULTS SEEG procedures included 38 patients and 525 implanted electrodes (294 using FBR and 231 using FTFR). DBS procedures included 50 patients and 96 implanted electrodes (65 using FBR and 31 using FTFR). Overall, FTFR registration was significantly more accurate (median 0.1 mm, IQR 0-0.4 mm) compared with FBR (median 1.3 mm, IQR 0.9-1.5 mm; p = 0.04). Likewise, FTFR had a significantly shorter duration of registration (median 84 minutes, IQR 77.3-95.3 minutes) when compared with FBR (median 110.5 minutes, IQR 107.3-138 minutes; p = 0.02). No significant differences were found when examining the radial entry point and Euclidean target implantation errors of each method. CONCLUSIONS FTFR with the Neurolocate system represents a technique that may decrease operative time while maintaining the high accuracy previously demonstrated by other stereotactic methods, despite an initial surgeon learning curve. It should be investigated in future studies to continue to improve stereotactic accuracies in neurosurgery.
Collapse
Affiliation(s)
- Kevin Hines
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Caio M. Matias
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Adam Leibold
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Ashwini Sharan
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Chengyuan Wu
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| |
Collapse
|
31
|
MAESAWA S, ISHIZAKI T, MUTOH M, ITO Y, TORII J, TANEI T, NAKATSUBO D, SAITO R. Clinical Impacts of Stereotactic Electroencephalography on Epilepsy Surgery and Associated Issues in the Current Situation in Japan. Neurol Med Chir (Tokyo) 2023; 63:179-190. [PMID: 37005247 DOI: 10.2176/jns-nmc.2022-0271] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2023] Open
Abstract
Stereotactic electroencephalography (SEEG) is receiving increasing attention as a safe and effective technique in the invasive evaluation for epileptogenic zone (EZ) detection. The main clinical question is whether the use of SEEG truly improves outcomes. Herein, we compared outcomes in our patients after three types of intracranial EEG (iEEG): SEEG, the subdural electrode (SDE), and a combined method using depth and strip electrodes. We present here our preliminary results from two demonstrative cases. Several international reports from large epilepsy centers found the following clinical advantages of SEEG: 1) three-dimensional analysis of structures, including bilateral and multilobar structures; 2) low rate of complications; 3) less pneumoencephalopathy and less patient burden during postoperative course, which allows the initiation of video-EEG monitoring immediately after implantation and does not require resection to be performed in the same hospitalization; and 4) a higher rate of good seizure control after resection. In other words, SEEG more accurately identified the EZ than the SDE method. We obtained similar results in our preliminary experiences under limited conditions. In Japan, as of August 2022, dedicated electrodes and SEEG accessories have not been approved and the use of the robot arm is not widespread. The Japanese medical community is hopeful that these issues will soon be resolved and that the experience with SEEG in Japan will align with that of large epilepsy centers internationally.
Collapse
Affiliation(s)
- Satoshi MAESAWA
- Department of Neurosurgery, Nagoya University School of Medicine
| | | | - Manabu MUTOH
- Department of Neurosurgery, Nagoya University School of Medicine
| | - Yoshiki ITO
- Department of Neurosurgery, Nagoya University School of Medicine
| | - Jun TORII
- Department of Neurosurgery, Nagoya University School of Medicine
| | - Takafumi TANEI
- Department of Neurosurgery, Nagoya University School of Medicine
| | | | - Ryuta SAITO
- Department of Neurosurgery, Nagoya University School of Medicine
| |
Collapse
|
32
|
A comparison between robot-guided and stereotactic frame-based stereoelectroencephalography (SEEG) electrode implantation for drug-resistant epilepsy. J Robot Surg 2022; 17:1013-1020. [DOI: 10.1007/s11701-022-01504-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 11/21/2022] [Indexed: 12/03/2022]
|
33
|
Does Stereoelectroencephalography Add Value in Patients with Lesional Epilepsy? World Neurosurg 2022; 167:e196-e203. [PMID: 35940500 DOI: 10.1016/j.wneu.2022.07.123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 07/25/2022] [Accepted: 07/26/2022] [Indexed: 11/21/2022]
Abstract
OBJECTIVE Stereoelectroencephalography (SEEG) has gained popularity as an invasive monitoring modality for epileptogenic zone (EZ) localization. The need and indications for SEEG in patients with evident brain lesions or associated abnormalities on imaging is debated. We report our experience with SEEG as a presurgical evaluation tool for patients with lesional epilepsy. METHODS A retrospective cohort study was performed of 131 patients with lesional or magnetic resonance imaging abnormality-associated medically refractory focal epilepsy who underwent resections from 2010 to 2017. Seventy-one patients had SEEG followed by resection, and 60 had no invasive recordings. Volumetric analysis of resection cavities from 3T magnetic resonance imaging was performed. RESULTS Mean lesion and resection volumes for SEEG and non-SEEG were 16.2 (standard deviation [SD] = 29) versus 23.7 cm3 (SD = 38.4) and 28.1 (SD = 23.2) versus 43.6 cm3 (SD = 43.5), respectively (P = 0.009). Comparing patients with seizure recurrence and patients who remained seizure free, significantly associated variables with seizure recurrence included mean number of failed antiseizure medications (6.86 [SD = 0.32] vs. 5.75 [SD = 0.32]; P = 0.01) and in SEEG patients the mean number of electrodes implanted (8.1 [SD = 0.8] vs. 5.0 [SD = 0.8]; P = 0.005). After multivariate analysis, only failed numbers of medication remained significantly associated with seizure recurrence. CONCLUSIONS Seizure outcomes did not correlate with final resection volume after SEEG evaluation. SEEG evaluation presurgically can be used to maintain the efficacy of resection and decrease the volume and subsequent risk of extensive tissue removal. We believe that this technology allows resective surgery to proceed in a subpopulation of patients with lesional epilepsy who may otherwise not have been considered surgical candidates.
Collapse
|
34
|
Anand A, Magnotti JF, Smith DN, Gadot R, Najera RA, Hegazy MIR, Gavvala JR, Shofty B, Sheth SA. Predictive value of magnetoencephalography in guiding the intracranial implant strategy for intractable epilepsy. J Neurosurg 2022; 137:1237-1247. [PMID: 35303696 DOI: 10.3171/2022.1.jns212943] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 01/31/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Magnetoencephalography (MEG) is a useful component of the presurgical evaluation of patients with epilepsy. Due to its high spatiotemporal resolution, MEG often provides additional information to the clinician when forming hypotheses about the epileptogenic zone (EZ). Because of the increasing utilization of stereo-electroencephalography (sEEG), MEG clusters are used to guide sEEG electrode targeting with increasing frequency. However, there are no predefined features of an MEG cluster that predict ictal activity. This study aims to determine which MEG cluster characteristics are predictive of the EZ. METHODS The authors retrospectively analyzed all patients who had an MEG study (2017-2021) and underwent subsequent sEEG evaluation. MEG dipoles and sEEG electrodes were reconstructed in the same coordinate space to calculate overlap among individual contacts on electrodes and MEG clusters. MEG cluster features-including number of dipoles, proximity, angle, density, magnitude, confidence parameters, and brain region-were used to predict ictal activity in sEEG. Logistic regression was used to identify important cluster features and to train a binary classifier to predict ictal activity. RESULTS Across 40 included patients, 196 electrodes (42.2%) sampled MEG clusters. Electrodes that sampled MEG clusters had higher rates of ictal and interictal activity than those that did not sample MEG clusters (ictal 68.4% vs 39.8%, p < 0.001; interictal 71.9% vs 44.6%, p < 0.001). Logistic regression revealed that the number of dipoles (odds ratio [OR] 1.09, 95% confidence interval [CI] 1.04-1.14, t = 3.43) and confidence volume (OR 0.02, 95% CI 0.00-0.86, t = -2.032) were predictive of ictal activity. This model was predictive of ictal activity with 77.3% accuracy (sensitivity = 80%, specificity = 74%, C-statistic = 0.81). Using only the number of dipoles had a predictive accuracy of 75%, whereas a threshold between 14 and 17 dipoles in a cluster detected ictal activity with 75.9%-85.2% sensitivity. CONCLUSIONS MEG clusters with approximately 14 or more dipoles are strong predictors of ictal activity and may be useful in the preoperative planning of sEEG implantation.
Collapse
Affiliation(s)
| | - John F Magnotti
- 2Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | | | | | | | | | - Jay R Gavvala
- 3Neurology, Baylor College of Medicine, Houston, Texas; and
| | | | | |
Collapse
|
35
|
Samanta D. Recent developments in stereo electroencephalography monitoring for epilepsy surgery. Epilepsy Behav 2022; 135:108914. [PMID: 36116362 DOI: 10.1016/j.yebeh.2022.108914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 11/03/2022]
Abstract
Recently the utilization of the stereo electroencephalography (SEEG) method has exploded globally. It is now the preferred method of intracranial monitoring for epilepsy. Since its inception, the basic tenet of the SEEG method remains the same: strategic implantation of intracerebral electrodes based on a hypothesis grounded on anatomo-electroclinical correlation, interpretation of interictal and ictal abnormalities, and formation of a surgical plan based on these data. However, there are recent advancements in all these domains-electrodes implantations, data interpretation, and therapeutic strategy- that can make the SEEG a more accessible and effective approach. In this narrative review, these newer developments are discussed and summarized. Regarding implantation, efficient commercial robotic systems are now increasingly available, which are also more accurate in implanting electrodes. In terms of ictal and interictal abnormalities, newer studies focused on correlating these abnormalities with pathological substrates and surgical outcomes and analyzing high-frequency oscillations and cortical-subcortical connectivity. These abnormalities can now be further quantified using advanced tools (spectrum, spatiotemporal, connectivity analysis, and machine learning algorithms) for objective and efficient interpretation. Another aspect of recent development is renewed interest in SEEG-based electrical stimulation mapping (ESM). The SEEG-ESM has been used in defining epileptogenic networks, mapping eloquent cortex (primarily language), and analyzing cortico-cortical evoked potential. Regarding SEEG-guided direct therapeutic strategy, several clinical studies evaluated the use of radiofrequency thermocoagulation. As the emerging SEEG-based diagnosis and therapeutics are better evolved, treatments aimed at specific epileptogenic networks without compromising the eloquent cortex will become more easily accessible to improve the lives of individuals with drug-resistant epilepsy (DRE).
Collapse
Affiliation(s)
- Debopam Samanta
- Neurology Division, Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, AR, United States.
| |
Collapse
|
36
|
Rahman RK, Tomlinson SB, Katz J, Galligan K, Madsen PJ, Tucker AM, Kessler SK, Kennedy BC. Stereoelectroencephalography before 2 years of age. Neurosurg Focus 2022; 53:E3. [DOI: 10.3171/2022.7.focus22336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 07/18/2022] [Indexed: 11/15/2022]
Abstract
OBJECTIVE
Stereoelectroencephalography (SEEG) is a widely used technique for localizing seizure onset zones prior to resection. However, its use has traditionally been avoided in children under 2 years of age because of concerns regarding pin fixation in the immature skull, intraoperative and postoperative electrode bolt security, and stereotactic registration accuracy. In this retrospective study, the authors describe their experience using SEEG in patients younger than 2 years of age, with a focus on the procedure’s safety, feasibility, and accuracy as well as surgical outcomes.
METHODS
A retrospective review of children under 2 years of age who had undergone SEEG while at Children’s Hospital of Philadelphia between November 2017 and July 2021 was performed. Data on clinical characteristics, surgical procedure, imaging results, electrode accuracy measurements, and postoperative outcomes were examined.
RESULTS
Five patients younger than 2 years of age underwent SEEG during the study period (median age 20 months, range 17–23 months). The mean age at seizure onset was 9 months. Developmental delay was present in all patients, and epilepsy-associated genetic diagnoses included tuberous sclerosis (n = 1), KAT6B (n = 1), and NPRL3 (n = 1). Cortical lesions included tubers from tuberous sclerosis (n = 1), mesial temporal sclerosis (n = 1), and cortical dysplasia (n = 3). The mean number of placed electrodes was 11 (range 6–20 electrodes). Bilateral electrodes were placed in 1 patient. Seizure onset zones were identified in all cases. There were no SEEG-related complications, including skull fracture, electrode misplacement, hemorrhage, infection, cerebrospinal fluid leakage, electrode pullout, neurological deficit, or death. The mean target point error for all electrodes was 1.0 mm. All patients proceeded to resective surgery, with a mean follow-up of 21 months (range 8–53 months). All patients attained a favorable epilepsy outcome, including Engel class IA (n = 2), IC (n = 1), ID (n = 1), and IIA (n = 1).
CONCLUSIONS
SEEG can be safely, accurately, and effectively utilized in children under age 2 with good postoperative outcomes using standard SEEG equipment. With minimal modification, this procedure is feasible in those with immature skulls and guides the epilepsy team’s decision-making for early and optimal treatment of refractory epilepsy through effective localization of seizure onset zones.
Collapse
Affiliation(s)
- Raphia K. Rahman
- Division of Neurosurgery, Children’s Hospital of Philadelphia, Pennsylvania
- Rowan University School of Osteopathic Medicine, Stratford, New Jersey
| | - Samuel B. Tomlinson
- Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Joshua Katz
- Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey
| | - Kathleen Galligan
- Division of Neurosurgery, Children’s Hospital of Philadelphia, Pennsylvania
| | - Peter J. Madsen
- Division of Neurosurgery, Children’s Hospital of Philadelphia, Pennsylvania
- Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Alexander M. Tucker
- Division of Neurosurgery, Children’s Hospital of Philadelphia, Pennsylvania
- Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Sudha Kilaru Kessler
- Division of Neurology, Children’s Hospital of Philadelphia, Pennsylvania; and
- Departments of Pediatrics and Neurology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| | - Benjamin C. Kennedy
- Division of Neurosurgery, Children’s Hospital of Philadelphia, Pennsylvania
- Department of Neurosurgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
37
|
El Hadji S, Bonilauri A, De Momi E, Castana L, Macera A, Berta L, Cardinale F, Baselli G. Validation of SART 3.5D algorithm for cerebrovascular dynamics and artery versus vein classification in presurgical 3D digital subtraction angiographies. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac8c7f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 08/24/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Classification of arteries and veins in cerebral angiograms can increase the safety of neurosurgical procedures, such as StereoElectroEncephaloGraphy, and aid the diagnosis of vascular pathologies, as arterovenous malformations. We propose a new method for vessel classification using the contrast medium dynamics in rotational digital subtraction angiography (DSA). After 3D DSA and angiogram segmentation, contrast enhanced projections are processed to suppress soft tissue and bone structures attenuation effect and further enhance the CM flow. For each voxel labelled as vessel, a time intensity curve (TIC) is obtained as a linear combination of temporal basis functions whose weights are addressed by simultaneous algebraic reconstruction technique (SART 3.5D), expanded to include dynamics. Each TIC is classified by comparing the areas under the curve in the arterial and venous phases. Clustering is applied to optimize the classification thresholds. On a dataset of 60 patients, a median value of sensitivity (90%), specificity (91%), and accuracy (92%) were obtained with respect to annotated arterial and venous voxels up to branching order 4–5. Qualitative results are also presented about CM arrival time mapping and its distribution in arteries and veins respectively. In conclusion, this study shows a valuable impact, at no protocol extra-cost or invasiveness, concerning surgical planning related to the enhancement of arteries as major organs at risk. Also, it opens a new scope on the pathophysiology of cerebrovascular dynamics and its anatomical relationships.
Collapse
|
38
|
Gonzalez-Martinez JA, Abou-Al-Shaar H, Mallela AN, McDowell MM, Henry L, Fernandes Cabral DT, Sweat J, Urban A, Fong J, Barot N, Castellano JF, Rajasekaran V, Bagic A, Snyderman CH, Gardner PA. The endoscopic anterior transmaxillary temporal pole approach for mesial temporal lobe epilepsies: a feasibility study. J Neurosurg 2022; 138:992-1001. [PMID: 36087323 DOI: 10.3171/2022.7.jns221062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 07/15/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE In mesial temporal lobe epilepsy (MTLE), the ideal surgical approach to achieve seizure freedom and minimize morbidity is an unsolved question. Selective approaches to mesial temporal structures often result in suboptimal seizure outcomes. The authors report the results of a pilot study intended to evaluate the clinical feasibility of using an endoscopic anterior transmaxillary (eATM) approach for minimally invasive management of MTLEs. METHODS The study is a prospectively collected case series of four consecutive patients who underwent the eATM approach for the treatment of MTLE and were followed for a minimum of 12 months. All participants underwent an epilepsy workup and surgical care at a tertiary referral comprehensive epilepsy center and had medically refractory epilepsy. The noninvasive evaluations and intracranial recordings of these patients confirmed the presence of anatomically restricted epileptogenic zones located in the mesial temporal structures. Data on seizure freedom at 1 year, neuropsychological outcomes, diffusion tractography, and adverse events were collected and analyzed. RESULTS By applying the eATM technique and approaching the far anterior temporal lobe regions, mesial-basal resections of the temporal polar areas and mesial temporal structures were successfully achieved in all patients (2 with left-sided approaches, 2 with right-sided approaches). No neurological complications or neuropsychological declines were observed. All 4 patients achieved Engel class Ia outcome up to the end of the follow-up period (19, 15, 14, and 12 months). One patient developed hypoesthesia in the left V2 distribution but there were no other adverse events. The low degree of white matter injury from the eATM approach was analyzed using high-definition fiber tractography in 1 patient as a putative mechanism for preserving neuropsychological function. CONCLUSIONS The described series demonstrates the feasibility and potential safety profile of a novel approach for medically refractory MTLE. The study affirms the feasibility of performing efficacious mesial temporal lobe resections through an eATM approach.
Collapse
Affiliation(s)
- Jorge A Gonzalez-Martinez
- 1Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh.,Departments of3Neurological Surgery
| | | | | | | | | | | | | | - Alexandra Urban
- 1Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh.,4Neurology, and
| | - Joanna Fong
- 1Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh.,4Neurology, and
| | - Niravkumar Barot
- 1Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh.,4Neurology, and
| | - James F Castellano
- 1Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh.,4Neurology, and
| | | | - Anto Bagic
- 1Epilepsy Center, University of Pittsburgh Medical Center, Pittsburgh.,4Neurology, and
| | - Carl H Snyderman
- 2Skull Base Center, University of Pittsburgh Medical Center, Pittsburgh; and.,5Otorhinolaryngology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Paul A Gardner
- 2Skull Base Center, University of Pittsburgh Medical Center, Pittsburgh; and.,Departments of3Neurological Surgery
| |
Collapse
|
39
|
Philipp L, Miller C, Wu C. Letter: Placement of Stereotactic Electroencephalography Depth Electrodes Using the Stealth Autoguide Robotic System: Technical Methods and Initial Results. Oper Neurosurg (Hagerstown) 2022; 23:e216-e217. [PMID: 35972123 DOI: 10.1227/ons.0000000000000351] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Accepted: 05/12/2022] [Indexed: 02/04/2023] Open
Affiliation(s)
- Lucas Philipp
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania, USA
| | - Christopher Miller
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania, USA.,Department of Neurosurgery, The University of Kansas School of Medicine, Kansas City, Kansas, USA
| | - Chengyuan Wu
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania, USA
| |
Collapse
|
40
|
Giridharan N, Katlowitz KA, Anand A, Gadot R, Najera RA, Shofty B, Snyder R, Larrinaga C, Prablek M, Karas PJ, Viswanathan A, Sheth SA. Robot-Assisted Deep Brain Stimulation: High Accuracy and Streamlined Workflow. Oper Neurosurg (Hagerstown) 2022; 23:254-260. [PMID: 35972090 DOI: 10.1227/ons.0000000000000298] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 04/03/2022] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND A number of stereotactic platforms are available for performing deep brain stimulation (DBS) lead implantation. Robot-assisted stereotaxy has emerged more recently demonstrating comparable accuracy and shorter operating room times compared with conventional frame-based systems. OBJECTIVE To compare the accuracy of our streamlined robotic DBS workflow with data in the literature from frame-based and frameless systems. METHODS We retrospectively reviewed 126 consecutive DBS lead placement procedures using a robotic stereotactic platform. Indications included Parkinson disease (n = 94), essential tremor (n = 21), obsessive compulsive disorder (n = 7), and dystonia (n = 4). Procedures were performed using a stereotactic frame for fixation and the frame pins as skull fiducials for robot registration. We used intraoperative fluoroscopic computed tomography for registration and postplacement verification. RESULTS The mean radial error for the target point was 1.06 mm (SD: 0.55 mm, range 0.04-2.80 mm) on intraoperative fluoroscopic computed tomography. The mean operative time for an asleep, bilateral implant without implantable pulse generator placement was 238 minutes (SD: 52 minutes), and skin-to-skin procedure time was 116 minutes (SD: 42 minutes). CONCLUSION We describe a streamlined workflow for DBS lead placement using robot-assisted stereotaxy with a comparable accuracy profile. Obviating the need for checking and switching coordinates, as is standard for frame-based DBS, also reduces the chance for human error and facilitates training.
Collapse
Affiliation(s)
- Nisha Giridharan
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Dasgupta D, Miserocchi A, McEvoy AW, Duncan JS. Previous, current, and future stereotactic EEG techniques for localising epileptic foci. Expert Rev Med Devices 2022; 19:571-580. [PMID: 36003028 DOI: 10.1080/17434440.2022.2114830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Drug-resistant focal epilepsy presents a significant morbidity burden globally, and epilepsy surgery has been shown to be an effective treatment modality. Therefore, accurate identification of the epileptogenic zone for surgery is crucial, and in those with unclear noninvasive data, stereoencephalography is required. AREAS COVERED This review covers the history and current practices in the field of intracranial EEG, particularly analyzing how stereotactic image-guidance, robot-assisted navigation, and improved imaging techniques have increased the accuracy, scope, and use of SEEG globally. EXPERT OPINION We provide a perspective on the future directions in the field, reviewing improvements in predicting electrode bending, image acquisition, machine learning and artificial intelligence, advances in surgical planning and visualization software and hardware. We also see the development of EEG analysis tools based on machine learning algorithms that are likely to work synergistically with neurophysiology experts and improve the efficiency of EEG and SEEG analysis and 3D visualization. Improving computer-assisted planning to minimize manual input from the surgeon, and seamless integration into an ergonomic and adaptive operating theater, incorporating hybrid microscopes, virtual and augmented reality is likely to be a significant area of improvement in the near future.
Collapse
Affiliation(s)
- Debayan Dasgupta
- Department of Clinical and Experimental Epilepsy, UCL Queen Square Institute of Neurology, University College London, London, UK.,Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK
| | - Anna Miserocchi
- Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK
| | - Andrew W McEvoy
- Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK
| | - John S Duncan
- Department of Clinical and Experimental Epilepsy, UCL Queen Square Institute of Neurology, University College London, London, UK
| |
Collapse
|
42
|
Alasfour A, Gabriel P, Jiang X, Shamie I, Melloni L, Thesen T, Dugan P, Friedman D, Doyle W, Devinsky O, Gonda D, Sattar S, Wang S, Halgren E, Gilja V. Spatiotemporal dynamics of human high gamma discriminate naturalistic behavioral states. PLoS Comput Biol 2022; 18:e1010401. [PMID: 35939509 PMCID: PMC9387937 DOI: 10.1371/journal.pcbi.1010401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 08/18/2022] [Accepted: 07/18/2022] [Indexed: 11/18/2022] Open
Abstract
In analyzing the neural correlates of naturalistic and unstructured behaviors, features of neural activity that are ignored in a trial-based experimental paradigm can be more fully studied and investigated. Here, we analyze neural activity from two patients using electrocorticography (ECoG) and stereo-electroencephalography (sEEG) recordings, and reveal that multiple neural signal characteristics exist that discriminate between unstructured and naturalistic behavioral states such as “engaging in dialogue” and “using electronics”. Using the high gamma amplitude as an estimate of neuronal firing rate, we demonstrate that behavioral states in a naturalistic setting are discriminable based on long-term mean shifts, variance shifts, and differences in the specific neural activity’s covariance structure. Both the rapid and slow changes in high gamma band activity separate unstructured behavioral states. We also use Gaussian process factor analysis (GPFA) to show the existence of salient spatiotemporal features with variable smoothness in time. Further, we demonstrate that both temporally smooth and stochastic spatiotemporal activity can be used to differentiate unstructured behavioral states. This is the first attempt to elucidate how different neural signal features contain information about behavioral states collected outside the conventional experimental paradigm.
Collapse
Affiliation(s)
- Abdulwahab Alasfour
- Department of Electrical Engineering, Kuwait University, Kuwait City, Kuwait
- Department of Electrical and Computer Engineering, UC San Diego, San Diego, California, United States of America
- * E-mail:
| | - Paolo Gabriel
- Department of Electrical and Computer Engineering, UC San Diego, San Diego, California, United States of America
| | - Xi Jiang
- Department of Neurosciences, UC San Diego, San Diego, California, United States of America
| | - Isaac Shamie
- Department of Neurosciences, UC San Diego, San Diego, California, United States of America
| | - Lucia Melloni
- Comprehensive Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York City, New York, United States of America
| | - Thomas Thesen
- Comprehensive Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York City, New York, United States of America
- Department of Biomedical Sciences, College of Medicine, University of Houston, Houston, Texas, United States of America
| | - Patricia Dugan
- Comprehensive Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York City, New York, United States of America
| | - Daniel Friedman
- Comprehensive Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York City, New York, United States of America
| | - Werner Doyle
- Comprehensive Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York City, New York, United States of America
| | - Orin Devinsky
- Comprehensive Epilepsy Center, Department of Neurology, New York University Grossman School of Medicine, New York City, New York, United States of America
| | - David Gonda
- Department of Neurosciences, UC San Diego, San Diego, California, United States of America
- Rady Children’s Hospital San Diego, San Diego, California, United States of America
| | - Shifteh Sattar
- Department of Neurosciences, UC San Diego, San Diego, California, United States of America
- Rady Children’s Hospital San Diego, San Diego, California, United States of America
| | - Sonya Wang
- Rady Children’s Hospital San Diego, San Diego, California, United States of America
- Department of Neurology, University of Minnesota Medical School, Minneapolis, Minnesota, United States of America
| | - Eric Halgren
- Department of Neurosciences, UC San Diego, San Diego, California, United States of America
| | - Vikash Gilja
- Department of Electrical and Computer Engineering, UC San Diego, San Diego, California, United States of America
| |
Collapse
|
43
|
Sheth SA, Bijanki KR, Metzger B, Allawala A, Pirtle V, Adkinson JA, Myers J, Mathura RK, Oswalt D, Tsolaki E, Xiao J, Noecker A, Strutt AM, Cohn JF, McIntyre CC, Mathew SJ, Borton D, Goodman W, Pouratian N. Deep Brain Stimulation for Depression Informed by Intracranial Recordings. Biol Psychiatry 2022; 92:246-251. [PMID: 35063186 PMCID: PMC9124238 DOI: 10.1016/j.biopsych.2021.11.007] [Citation(s) in RCA: 48] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 11/01/2021] [Accepted: 11/02/2021] [Indexed: 11/02/2022]
Abstract
The success of deep brain stimulation (DBS) for treating Parkinson's disease has led to its application to several other disorders, including treatment-resistant depression. Results with DBS for treatment-resistant depression have been heterogeneous, with inconsistencies largely driven by incomplete understanding of the brain networks regulating mood, especially on an individual basis. We report results from the first subject treated with DBS for treatment-resistant depression using an approach that incorporates intracranial recordings to personalize understanding of network behavior and its response to stimulation. These recordings enabled calculation of individually optimized DBS stimulation parameters using a novel inverse solution approach. In the ensuing double-blind, randomized phase incorporating these bespoke parameter sets, DBS led to remission of symptoms and dramatic improvement in quality of life. Results from this initial case demonstrate the feasibility of this personalized platform, which may be used to improve surgical neuromodulation for a vast array of neurologic and psychiatric disorders.
Collapse
Affiliation(s)
- Sameer A. Sheth
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA,Corresponding Author: Sameer A. Sheth, MD, PhD, 7200 Cambridge Street, Suite 9B, Houston, TX 77030, 310-922-2596,
| | - Kelly R. Bijanki
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Brian Metzger
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Anusha Allawala
- Department of Engineering, Brown University, Providence, RI, 02912 USA
| | - Victoria Pirtle
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Josh A. Adkinson
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - John Myers
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Raissa K. Mathura
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Denise Oswalt
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Evangelia Tsolaki
- Department of Neurosurgery, University of California, Los Angeles, Los Angeles, CA, 90095 USA
| | - Jiayang Xiao
- Department of Neurosurgery, Baylor College of Medicine, Houston TX, 77030 USA
| | - Angela Noecker
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106 USA
| | - Adriana M. Strutt
- Department of Neurology, Baylor College of Medicine, Houston TX, 77030 USA
| | - Jeffrey F. Cohn
- Department of Psychology, University of Pittsburgh, Pittsburgh, PA, 19104 USA
| | - Cameron C. McIntyre
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106 USA
| | - Sanjay J. Mathew
- Department of Psychiatry, Baylor College of Medicine, Houston TX, 77030 USA
| | - David Borton
- Department of Engineering, Brown University, Providence, RI, 02912 USA
| | - Wayne Goodman
- Department of Psychiatry, Baylor College of Medicine, Houston TX, 77030 USA
| | - Nader Pouratian
- Department of Neurosurgery, University of California, Los Angeles, Los Angeles, CA, 90095 USA
| |
Collapse
|
44
|
Iredale E, Voigt B, Rankin A, Kim KW, Chen JZ, Schmid S, Hebb MO, Peters TM, Wong E. Planning System for the Optimization of Electric Field Delivery using Implanted Electrodes for Brain Tumor Control. Med Phys 2022; 49:6055-6067. [PMID: 35754362 DOI: 10.1002/mp.15825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 06/06/2022] [Accepted: 06/17/2022] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND The use of non-ionizing electric fields from low intensity voltage sources (<10 V) to control malignant tumor growth is showing increasing potential as a cancer treatment modality. A method of applying these low intensity electric fields using multiple implanted electrodes within or adjacent to tumor volumes has been termed as intratumoral modulation therapy (IMT). PURPOSE This study explores advancements in the previously established IMT optimization algorithm, and the development of a custom treatment planning system for patient specific IMT. The practicality of the treatment planning system is demonstrated by implementing the full optimization pipeline on a brain phantom with robotic electrode implantation, post-operative imaging, and treatment stimulation. METHODS The integrated planning pipeline in 3D Slicer begins with importing and segmenting patient magnetic resonance images (MRI) or computed tomography (CT) images. The segmentation process is manual, followed by a semi-automatic smoothing step that allows the segmented brain and tumor mesh volumes to be smoothed and simplified by applying selected filters. Electrode trajectories are planned manually on the patient MRI or CT by selecting insertion and tip coordinates for a chosen number of electrodes. The electrode tip positions, and stimulation parameters (phase shift and voltage) can then be optimized with the custom semi-automatic IMT optimization algorithm where users can select the prescription electric field, voltage amplitude limit, tissue electrical properties, nearby organs at risk, optimization parameters (electrode tip location, individual contact phase shift and voltage), desired field coverage percent, and field conformity optimization. Tables of optimization results are displayed, and the resulting electric field is visualized as a field-map superimposed on the MR or CT image, with 3D renderings of the brain, tumor, and electrodes. Optimized electrode coordinates are transferred to robotic electrode implantation software to enable planning and subsequent implantation of the electrodes at the desired trajectories. RESULTS An IMT treatment planning system was developed that incorporates patient specific MRI or CT, segmentation, volume smoothing, electrode trajectory planning, electrode tip location and stimulation parameter optimization, and results visualization. All previous manual pipeline steps operating on diverse software platforms were coalesced into a single semi-automated 3D Slicer based user interface. Brain phantom validation of the full system implementation was successful in pre-operative planning, robotic electrode implantation, and post-operative treatment planning to adjust stimulation parameters based on actual implant locations. Voltage measurements were obtained in the brain phantom to determine the electrical parameters of the phantom and validate the simulated electric field distribution. CONCLUSIONS A custom treatment planning and implantation system for IMT has been developed in this study, and validated on a phantom brain model, providing an essential step in advancing IMT technology towards future clinical safety and efficacy investigations. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Erin Iredale
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Brynn Voigt
- Department of Physics and Astronomy, Western University, London, ON, Canada
| | - Adam Rankin
- Robarts Research Institute, Western University, London, ON, Canada
| | - Kyungho W Kim
- Department of Physics and Astronomy, Western University, London, ON, Canada
| | - Jeff Z Chen
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Susanne Schmid
- Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Matthew O Hebb
- Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Department of Clinical Neurological Sciences, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Terry M Peters
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Robarts Research Institute, Western University, London, ON, Canada
| | - Eugene Wong
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Department of Physics and Astronomy, Western University, London, ON, Canada
| |
Collapse
|
45
|
Kojima Y, Uda T, Kawashima T, Koh S, Hattori M, Mito Y, Kunihiro N, Ikeda S, Umaba R, Goto T. Primary Experiences with Robot-assisted Navigation-based Frameless Stereo-electroencephalography: Higher Accuracy than Neuronavigation-guided Manual Adjustment. Neurol Med Chir (Tokyo) 2022; 62:361-368. [PMID: 35613881 PMCID: PMC9464478 DOI: 10.2176/jns-nmc.2022-0010] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
The use of robot-assisted frameless stereotactic electroencephalography (SEEG) is becoming more common. Among available robotic arms, Stealth Autoguide (SA) (Medtronic, Minneapolis, MN, USA) functions as an optional instrument of the neuronavigation system. The aims of this study were to present our primary experiences with SEEG using SA and to compare the accuracy of implantation between SA and navigation-guided manual adjustment (MA). Seventeen electrodes from two patients who underwent SEEG with SA and 18 electrodes from four patients with MA were retrospectively reviewed. We measured the distance between the planned location and the actual location at entry (De) and the target (Dt) in each electrode. The length of the trajectory did not show a strong correlation with Dt in SA (Pearson's correlation coefficient [r] = 0.099, p = 0.706) or MA (r = 0.233, p = 0.351). De and Dt in SA were shorter than those in MA (1.99 ± 0.90 vs 4.29 ± 1.92 mm, p = 0.0002; 3.59 ± 2.22 vs 5.12 ± 1.40 mm, p = 0.0065, respectively). SA offered higher accuracy than MA both at entry and target. Surgical times per electrode were 38.9 and 32 min in the two patients with SA and ranged from 51.6 to 88.5 min in the four patients with MA. During the implantation period of 10.3 ± 3.6 days, no patients experienced any complications.
Collapse
Affiliation(s)
- Yuichiro Kojima
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine
| | - Takehiro Uda
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine.,Department of Pediatric Neurosurgery, Osaka City General Hospital
| | - Toshiyuki Kawashima
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine
| | - Saya Koh
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine
| | - Masato Hattori
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine
| | - Yuki Mito
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine
| | | | - Shohei Ikeda
- Department of Pediatric Neurosurgery, Osaka City General Hospital
| | - Ryoko Umaba
- Department of Pediatric Neurosurgery, Osaka City General Hospital
| | - Takeo Goto
- Department of Neurosurgery, Osaka Metropolitan University Graduate School of Medicine
| |
Collapse
|
46
|
Lin L, Sun M, Xu C, Gao Y, Xu H, Yang X, He H, Wang B, Xie L, Chai G. Assessment of Robot-Assisted Mandibular Contouring Surgery in Comparison With Traditional Surgery: A Prospective, Single-Center, Randomized Controlled Trial. Aesthet Surg J 2022; 42:567-579. [PMID: 34791018 DOI: 10.1093/asj/sjab392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Few clinical studies on robot-assisted surgery (RAS) for mandibular contouring have been reported. OBJECTIVES The aim of this study was to follow the long-term effectiveness and safety of RAS for craniofacial bone surgery. METHODS This small-sample, early-phase, prospective, randomized controlled study included patients diagnosed with mandibular deformity requiring mandibular contouring surgery. Patients of both genders aged 18 to 30 years without complicated craniofacial repair defects were enrolled and randomly assigned in a 1:1 ratio by a permuted-block randomized assignments list generated by the study statistician. The primary outcomes were the positioning accuracy and accuracy of the osteotomy plane angle 1 week after surgery. Surgical auxiliary measurement index, patient satisfaction scale, surgical pain scale, perioperative period, and complications at 1 week, 1 month, and 6 months after surgery were also analyzed. RESULTS One patient was lost to follow-up, resulting in a total of 14 patients in the traditional surgery group and 15 in the robot-assisted group (mean [standard deviation] age, 22.65 [3.60] years). Among the primary outcomes, there was a significant difference in the positioning accuracy (2.91 mm vs 1.65 mm; P < 0.01) and angle accuracy (13.26º vs 4.85º; P < 0.01) between the 2 groups. Secondary outcomes did not significantly differ. CONCLUSIONS Compared to traditional surgery, robot-assisted mandibular contouring surgery showed improved precision in bone shaving, as well as higher safety. LEVEL OF EVIDENCE: 2
Collapse
Affiliation(s)
- Li Lin
- Department of Plastic and Reconstructive Surgery, Shanghai 9th People’s Hospital, School of Medicine, Shanghai Jiao Tong University , Shanghai, China
| | - Mengzhe Sun
- Department of Plastic and Reconstructive Surgery, Shanghai 9th People’s Hospital, School of Medicine, Shanghai Jiao Tong University , Shanghai, China
| | - Cheng Xu
- Institute of Forming Technology and Equipment, Shanghai Jiao Tong University, Xuhui Campus , Shanghai, China
| | - Yuan Gao
- Institute of Forming Technology and Equipment, Shanghai Jiao Tong University, Xuhui Campus , Shanghai, China
| | - Haisong Xu
- Department of Plastic and Reconstructive Surgery, Shanghai 9th People’s Hospital, School of Medicine, Shanghai Jiao Tong University , Shanghai, China
| | - Xianxian Yang
- Department of Plastic and Reconstructive Surgery, Shanghai 9th People’s Hospital, School of Medicine, Shanghai Jiao Tong University , Shanghai, China
| | - Hao He
- Department of Biostatistics, Clinical Research Institute, Shanghai Jiao Tong University School of Medicine , Shanghai, China
| | - Bingshun Wang
- Department of Biostatistics, Clinical Research Institute, Shanghai Jiao Tong University School of Medicine , Shanghai, China
| | - Le Xie
- Institute of Medical Robotics, Shanghai Jiao Tong University, Minhang Campus , Shanghai, China
| | - Gang Chai
- Department of Plastic and Reconstructive Surgery, Shanghai 9th People’s Hospital, School of Medicine, Shanghai Jiao Tong University , Shanghai, China
| |
Collapse
|
47
|
Robertson FC, Wu KC, Sha RM, Amich JM, Lal A, Lee BH, Kirollos RW, Chen MW, Gormley WB. Stereotactic Neurosurgical Robotics With Real-Time Patient Tracking: A Cadaveric Study. Oper Neurosurg (Hagerstown) 2022; 22:425-432. [DOI: 10.1227/ons.0000000000000155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 12/15/2021] [Indexed: 11/19/2022] Open
|
48
|
Nagahama Y, Alexander AL, O'Neill BR. Intracranial pressure monitoring during stereoelectroencephalography implantation: a technical note. J Neurosurg Pediatr 2022; 29:454-457. [PMID: 35061987 DOI: 10.3171/2021.12.peds21490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Accepted: 12/09/2021] [Indexed: 11/06/2022]
Abstract
Stereoelectroencephalography (SEEG) has become increasingly employed as a critical component of epilepsy workups for patients with drug-resistant epilepsy when information from noninvasive studies is not conclusive and sufficient to guide epilepsy surgery. Although exceedingly rare, clinically significant hemorrhagic complications can be caused during SEEG implantation procedures. Intracranial hemorrhage (ICH) can be difficult to recognize due to the minimally invasive nature of SEEG. The authors describe their technique using a commercially available intraparenchymal intracranial pressure (ICP) monitor as a method for early intraoperative detection of ICH during SEEG implantation. Between May 2019 and July 2021, 18 pediatric patients underwent SEEG implantation at a single, freestanding children's hospital with the use of an ICP monitor during the procedure. No patients experienced complications resulting from this technique. The authors have relayed their rationale for ICP monitor use during SEEG, the technical considerations, and the safety profile. In addition, they have reported an illustrative case in which the ICP monitor proved crucial in early detection of ICH during SEEG implantation.
Collapse
Affiliation(s)
- Yasunori Nagahama
- 1Division of Pediatric Neurosurgery, Children's Hospital Colorado, Aurora.,2Department of Neurosurgery, University of Colorado Anschutz School of Medicine, Aurora, Colorado; and.,3Department of Neurosurgery, Rutgers-Robert Wood Johnson Medical School, New Brunswick, New Jersey
| | - Allyson L Alexander
- 1Division of Pediatric Neurosurgery, Children's Hospital Colorado, Aurora.,2Department of Neurosurgery, University of Colorado Anschutz School of Medicine, Aurora, Colorado; and
| | - Brent R O'Neill
- 1Division of Pediatric Neurosurgery, Children's Hospital Colorado, Aurora.,2Department of Neurosurgery, University of Colorado Anschutz School of Medicine, Aurora, Colorado; and
| |
Collapse
|
49
|
Robot-assisted stereotactic multiple brain abscesses' puncture: technical case report. Acta Neurochir (Wien) 2022; 164:845-851. [PMID: 34410501 DOI: 10.1007/s00701-021-04955-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 07/26/2021] [Indexed: 10/20/2022]
Abstract
We report a case of multiple brain abscesses' puncture, employing the ROSA™ Brain surgical robot (Zimmer Biomet) and the O-arm® O2 Imaging System (Medtronic). A 51-year-old man was diagnosed with multiple supratentorial ring enhancing cystic lesions consistent with brain abscesses. A neurological deterioration occurred despite broad spectrum antibiotic therapy, due to mass effect of the abscesses. Stereotactic aspiration was performed using the described technique, allowing a single stage puncture of the cerebral lesions. In this case, the robot-assisted and image-guided procedure permitted an accurate, quick, and efficient targeting of the multiple abscesses for drainage.
Collapse
|
50
|
Karasin B, Hardinge T, Eskuchen L, Watkinson J. Care of the Patient Undergoing Robotic-Assisted Brain Biopsy With Stereotactic Navigation: An Overview. AORN J 2022; 115:223-236. [PMID: 35213041 DOI: 10.1002/aorn.13622] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/28/2021] [Accepted: 10/05/2021] [Indexed: 11/09/2022]
Abstract
Brain tumors can cause pressure, swelling, and functional changes to the surrounding tissue and lead to sensorimotor symptoms. Such tumors are either benign or malignant and their origin can be primary or metastatic. Although diagnostic studies (eg, computed tomography and magnetic resonance imaging) can reveal a mass and provide information on its location, size, and relationship to surrounding structures, the most definitive way to make a diagnosis requires a brain biopsy tissue sample. The robotic-assisted technique with stereotactic navigation allows the neurosurgeon to merge preoperative scans with a computer program to provide a map of the planned surgical trajectory and use the robot to obtain the biopsy. The robotic-assisted brain biopsy with navigation provides improved accuracy with small incisions that may not be possible using non-robotic-assisted techniques. This article provides background information and an overview of the nursing considerations for patients undergoing robotic-assisted brain biopsy procedures.
Collapse
|