1
|
Habibi MA, Mirjnani MS, Zafari R, saadat Z, Zahedinasab B, Delbari P, Zare AH, Sheipouri A, Mobader Sani S. The safety and efficiency of SMART coil for brain aneurysm: A systematic review and meta-analysis. Neuroradiol J 2024:19714009241303095. [PMID: 39579016 PMCID: PMC11585007 DOI: 10.1177/19714009241303095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2024] Open
Abstract
BACKGROUND The SMART coil system is a relatively new generation of embolic coils consisting of a bare platinum coil, a detachment pusher, and a detachment handle. This study investigated the safety and efficiency of the SMART coil system in treating cerebral aneurysms. METHOD PubMed/Medline, Embase, Web of Science, and Scopus were searched until October, 1st 2023. Non-English language, non-human studies, and non-original studies were excluded. RESULTS A total of 7 studies were included. The results of our study reflected complete aneurysm occlusion (mRRC1) rate of 45% (95% CI, 0.35-0.56), neck remnant aneurysm (mRRC2) rate of 36% (95% CI, 0.30-0.42), and residual aneurysm (mRRC3) rate of 22% (95% CI, 0.12-0.38) during post-procedural assessment. Moreover, considering longest follow-up, our study showed complete aneurysm occlusion (mRRC1) rate of 66% (95% CI, 0.43-0.84), neck remnant aneurysm (mRRC2) rate of 27% (95% CI, 0.13-0.49), and residual aneurysm (mRRC3) rate of 9% (95% CI, 0.04-0.20). In addition, recanalization and retreatment rates were reported 10% (95% CI, 0.06-0.17) and 9% (95% CI, 0.06-0.12), respectively. The rates of adverse and serious adverse events were 9% (95% CI, 0.07-0.10) and 6% (95% CI, 0.01-0.22), respectively. Three studies reported a stroke rate which was 2% (95% CI, 0.00-0.13), and five studies reported a mortality rate which was 6% (95% CI, 0.03-0.11). CONCLUSION The findings suggested that the SMART coil can be a safe and efficient treatment in patients with intracranial aneurysms compared to other available treatment methods.
Collapse
Affiliation(s)
- Mohammad Amin Habibi
- Department of Neurosurgery, Shariati Hospital, Tehran University of Medical Sciences, Iran
| | | | - Rasa Zafari
- School of Medicine, Tehran University of Medical Sciences, Iran
| | - Zahra saadat
- Cardiovasculr Research Centre, Hormozgan University of Medical sciences, Iran
| | | | - Pouria Delbari
- School of Medicine, Tehran University of Medical Sciences, Iran
| | | | - Amirmahdi Sheipouri
- Students’ Scientific Research Center (SSRC), Tehran University of Medical Sciences, Iran
| | - Sheida Mobader Sani
- Students’ Scientific Research Center (SSRC), Tehran University of Medical Sciences, Iran
| |
Collapse
|
2
|
Patel SA, Vivanco-Suarez J, Palepu C, Chisvo NS, Patel S, Gajjar AA, Woodiwiss T, Burkhardt JK, Srinivasan VM. Intrasaccular Flow Disruption: Examining Global Access and Research Trends. World Neurosurg 2024; 189:439-446.e16. [PMID: 38972381 DOI: 10.1016/j.wneu.2024.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Accepted: 07/01/2024] [Indexed: 07/09/2024]
Abstract
The Woven EndoBridge (WEB) and other intrasaccular flow disruptors show promise in treating intracranial aneurysms. We performed a bibliometric analysis to provide novel insights into the trends and trajectory of these devices. We systematically assessed bibliometric data such as citations, journals, study designs, open access status, and multi-institutional involvement for the top-cited articles on WEB and other disruptors. The top 100 cited studies on the WEB had citations from 7 to 144 (mean ± standard deviation 35.6 ± 29.5), while only 33 studies were published for other intrasaccular flow disruptors (4.24 ± 8.45). Of the other devices, the Contour has the most publications (n = 21). Retrospective reviews were the most common study design for both WEB and other intrasaccular devices. France published the most studies in the top 100 WEB papers (n = 35), while Germany led for other flow disruptors (n = 10). In all studies analyzed, no senior authors from Africa are present. The top 100 WEB publications had a higher mean citation count (35.6 vs. 4.24, P<0.001), higher mean citations per year (5.24 vs. 1.03, P<0.01), and a higher proportion of multi-institutional collaborations (44.0% vs. 12.1%, P<0.01) than other intrasaccular flow disruptors. In conclusion, countries with the most publications on WEB are not necessarily the ones leading the way with newer intrasaccular devices, while study designs remain similar. There is a limited contribution to the literature outside of Europe and North America. Our findings identify notable collaborators and trends, providing a snapshot of the field and a roadmap for future research.
Collapse
Affiliation(s)
- Shray A Patel
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
| | - Juan Vivanco-Suarez
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania, USA
| | - Chandrasekhar Palepu
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania, USA
| | - Nathan S Chisvo
- Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Saarang Patel
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania, USA
| | - Avi A Gajjar
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania, USA
| | - Timothy Woodiwiss
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA
| | - Jan-Karl Burkhardt
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania, USA
| | - Visish M Srinivasan
- Department of Neurosurgery, Hospital of the University of Pennsylvania, Penn Medicine, Philadelphia, Pennsylvania, USA
| |
Collapse
|
3
|
Nasra M, Pavlin-Premrl D, Protto S, Khabaza A, Gan C, Siasat P, Jhamb A, Smith P, Moore J, Russell J, Ren Y, Slater LA, Chandra RV, Chong W, Shaygi B, Brooks M, Maingard J, Asadi H. The Clinical and Radiological Outcomes of the Multimodal Use of the Woven EndoBridge Device: A Large Multicenter Study. World Neurosurg 2024; 188:e168-e176. [PMID: 38763461 DOI: 10.1016/j.wneu.2024.05.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 05/12/2024] [Accepted: 05/13/2024] [Indexed: 05/21/2024]
Abstract
BACKGROUND The Woven EndoBridge (WEB) is a device used for intrasaccular flow diversion, designed for the elimination of wide-necked bifurcation aneurysms from the circulation. In this study, we aim to assess the safety and efficacy of the WEB and its uses in treating aneurysms of different morphologies and locations. METHODS In a retrospective analysis, we compiled a comprehensive dataset from patients treated with the WEB device across three major Australian neurovascular centers from May 2017 to September 2023. The case series encompassed a spectrum of aneurysm types, including wide-necked bifurcation, sidewall, and irregularly shaped aneurysms, as well as cases previously managed with alternative therapeutic strategies. This study additionally encompasses cases where aneurysms were managed using the WEB device in combination with supplementary endovascular devices. RESULTS The study included 169 aneurysms in 161 patients. The rate of satisfactory aneurysm occlusion was 85.6%, with 86.7% of patients maintaining good functional status at their most recent follow-up. The procedure exhibited a low mortality rate of 0.6% and a thromboembolic complication rate of 7.1% (n = 12/161). There were no instances of postoperative re-rupture and the procedure-related hemorrhage rate was low (1.2%, n = 2/169), aligning with the literature regarding the safety and efficacy of the WEB device. CONCLUSIONS Our multicenter trial reinforces the WEB device's role as an effective and safe modality for intracranial aneurysm management, supporting its expanded application beyond wide-necked bifurcation aneurysms. Further prospective studies are required to delineate its evolving role fully.
Collapse
Affiliation(s)
- Mohamed Nasra
- Department of Medicine, Northern Health, Melbourne, Victoria, Australia.
| | - Davor Pavlin-Premrl
- Department of Neurology, Austin Health, Melbourne Victoria, Australia; Department of Interventional Neuroradiology, Austin Health, Melbourne, Victoria, Australia; Department of Interventional Neuroradiology, St Vincent's Health, Fitzroy, Victoria, Australia
| | - Sara Protto
- Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia
| | - Ali Khabaza
- Department of Interventional Neuroradiology, Austin Health, Melbourne, Victoria, Australia; Department of Interventional Neuroradiology, St Vincent's Health, Fitzroy, Victoria, Australia; Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia
| | - Calvin Gan
- Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia
| | - Paul Siasat
- Department of Surgery, St. Vincent's Health, Fitzroy, Victoria, Australia
| | - Ashu Jhamb
- Department of Radiology, St Vincent's Health, Fitzroy, Victoria, Australia
| | - Paul Smith
- Department of Neurosurgery, St Vincent's Health, Fitzroy, Australia; Melbourne Medical School, The University of Melbourne, Parkville, Victoria, Australia
| | - Justin Moore
- Department of Neurosurgery, Monash Health, Clayton, Victoria, Australia
| | - Jeremy Russell
- Department of Neurosurgery, Austin Health, Heidelberg, Victoria, Australia
| | - Yifan Ren
- Department of Radiology, Austin Health, Heidelberg, Victoria, Australia
| | - Lee-Anne Slater
- Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia
| | - Ronil V Chandra
- Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia
| | - Winston Chong
- Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia
| | - Behnam Shaygi
- Department of Interventional Radiology, London North West University Healthcare NHS Trust, London, UK
| | - Mark Brooks
- Department of Interventional Neuroradiology, Austin Health, Melbourne, Victoria, Australia; Department of Interventional Neuroradiology, St Vincent's Health, Fitzroy, Victoria, Australia
| | - Julian Maingard
- Department of Interventional Neuroradiology, Austin Health, Melbourne, Victoria, Australia; Department of Interventional Neuroradiology, St Vincent's Health, Fitzroy, Victoria, Australia; School of Medicine, Deakin University, Waurn Ponds, Victoria, Australia
| | - Hamed Asadi
- Department of Interventional Neuroradiology, Austin Health, Melbourne, Victoria, Australia; Department of Interventional Neuroradiology, Monash Health, Clayton, Victoria, Australia; School of Medicine, Deakin University, Waurn Ponds, Victoria, Australia
| |
Collapse
|
4
|
Alpay K, Nania A, Raj R, Numminen J, Parkkola R, Rautio R, Downer J. Long term WEB results - still going strong at 5 years? Interv Neuroradiol 2024; 30:517-523. [PMID: 36397733 PMCID: PMC11483733 DOI: 10.1177/15910199221139542] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Accepted: 10/31/2022] [Indexed: 02/17/2024] Open
Abstract
OBJECTIVE The aim of our multi-center study is to examine 5-year radiological outcomes of intracranial aneurysms (IAs) treated with the Woven EndoBridge (WEB). METHODS All patients treated with WEB between January 2013 and December 2016 were included. Patient and aneurysm characteristic data was collected from the electronic patient record. Aneurysm occlusion was assessed using a 3-grade scale: complete occlusion, neck remnant, and aneurysm remnant. Complete occlusion and neck remnant were considered as adequate occlusion, whereas aneurysm remnant was assessed as an inadequate occlusion. RESULTS A total of 66 patients (72.7% female) with 66 IAs (n = 25 acutely ruptured) were treated with WEB. The mean age of patients was 55.6 years (range: 36-71 years). The mean width of the aneurysm neck was 4.5 mm (range: 2-9 mm). 5-year imaging follow-up data was not available for 16.6% patients (n = 11). During the follow up period, 14.5% of IAs (n = 8/55) required retreatment within 24 months of initial treatment with the WEB. A total of 55 IAs were analyzed for 5-year radiological outcome. Of these, including IAs required retreatment, 47.3% of IAs (n = 26/55) were occluded completely, 36.4% (n = 20/55) had neck remnant and 16.3% (n = 9/55) had recanalized. 83.7% of IAs were occluded adequately. None of the IAs rebled after initial treatment with WEB. CONCLUSION WEB can provide acceptable adequate occlusion rates at 5 years. Furthermore, recanalization appears to be unlikely after the first two years post-treatment. The results of large studies are needed to confirm these promising long term radiological outcomes.
Collapse
Affiliation(s)
- Kemal Alpay
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Alberto Nania
- Department of Clinical Neurosciences, University of Edinburgh, Edinburgh, UK
| | - Rahul Raj
- Department of Neurosurgery, Helsinki University Hospital and University of Helsinki, Finland
| | - Jussi Numminen
- Department of Radiology, Helsinki University Hospital, Helsinki, Finland
| | - Riitta Parkkola
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Riitta Rautio
- Department of Radiology, Turku University Hospital, Turku, Finland
| | - Jonathan Downer
- Department of Clinical Neurosciences, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
5
|
Wadhwa A, Mensah E, Young M, Ogilvy CS. Variability patterns in dual antiplatelet therapy following endovascular repair of intracranial aneurysms: Insight into regimen heterogeneity and the need for a consensus. Acta Neurochir (Wien) 2024; 166:271. [PMID: 38888678 DOI: 10.1007/s00701-024-06137-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Accepted: 05/20/2024] [Indexed: 06/20/2024]
Abstract
This comprehensive review delves into the evolving field of neurointervention for intracranial aneurysms, exploring the critical adjunct of Dual Antiplatelet Therapy (DAPT) to endovascular coiling, stent-assisted coiling (SAC), flow-diversion stents, and flow-disruption (intrasaccular) devices. Despite growing evidence supporting the success of DAPT in reducing thromboembolic events, the lack of consensus on optimal regimens, doses, and duration is evident. Factors contributing to this variability include genetic polymorphisms affecting treatment response and ongoing debates regarding the clinical significance of hemorrhagic complications associated with DAPT. This review analyzes pre- and post-procedural antiplatelet usage across various interventions. The imperative lies in ongoing research to define optimal DAPT durations, ensuring a nuanced approach to the delicate balance between thrombosis and hemorrhage in intracranial aneurysm management.
Collapse
Affiliation(s)
- Aryan Wadhwa
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis St, Boston, MA, 02215, USA
| | - Emmanuel Mensah
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis St, Boston, MA, 02215, USA
| | - Michael Young
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis St, Boston, MA, 02215, USA
| | - Christopher S Ogilvy
- Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis St, Boston, MA, 02215, USA.
| |
Collapse
|
6
|
Teranishi K, Ikemura R, Arai S, Mitome-Mishima Y, Kitamura T, Kondo A, Oishi H. Endovascular Treatment of Bifurcation Aneurysms with the Woven EndoBridge: Product Features and Selected Results of Off-Label Use. JOURNAL OF NEUROENDOVASCULAR THERAPY 2024; 18:65-74. [PMID: 38559453 PMCID: PMC10973567 DOI: 10.5797/jnet.ra.2023-0086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 01/25/2024] [Indexed: 04/04/2024]
Abstract
Treatment for wide-neck bifurcation cerebral aneurysms (WNBAs) is widely performed by endovascular treatment as well as open surgical clipping. However, due to factors such as the shape and size of the aneurysms, as well as the anatomical features of surrounding branch vessels, there are some cases in which simple coiling or conventional adjunctive techniques, such as balloon-assisted or neck bridge stent-assisted coiling, are not sufficient to achieve a satisfactory cure. Against this backdrop, the device known as the Woven EndoBridge (WEB) (MicroVention, Aliso Viejo, CA, USA) was developed and can be deployed directly into the aneurysm for treatment. Over a decade has passed since its development, and it is now used in many countries worldwide. This review provides insights into the evolution of the WEB device from its development to the date of this writing, highlighting the unique features of the device and its treatment indications. Additionally, it discusses the posttreatment course, perspectives on recurrence and retreatment, imaging assessments, and potential off-label use based on numerous studies primarily conducted in Europe and the USA.
Collapse
Affiliation(s)
- Kohsuke Teranishi
- Department of Neurosurgery, Juntendo University School of Medicine, Tokyo, Japan
| | - Ryogo Ikemura
- Department of Neurosurgery, Juntendo University School of Medicine, Tokyo, Japan
| | - Sho Arai
- Department of Neurosurgery, Juntendo University School of Medicine, Tokyo, Japan
| | | | - Takayuki Kitamura
- Department of Neurosurgery, Juntendo University School of Medicine, Tokyo, Japan
| | - Akihide Kondo
- Department of Neurosurgery, Juntendo University School of Medicine, Tokyo, Japan
| | - Hidenori Oishi
- Department of Neuroendovascular Therapy, Juntendo University Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
7
|
Rodriguez-Erazú F, Cortese J, Mihalea C, Popica A, Chalumeau V, Vasconcellos N, Gallas S, Ikka L, Grimaldi L, Caroff J, Spelle L. Thromboembolic Events With the Woven Endobridge Device: Incidence, Predictive Factors, and Management. Neurosurgery 2024; 94:183-192. [PMID: 37728333 DOI: 10.1227/neu.0000000000002696] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 08/01/2023] [Indexed: 09/21/2023] Open
Abstract
BACKGROUND AND OBJECTIVES The Woven EndoBridge (WEB) device has been increasingly used to treat wide-neck aneurysms showing a safe and effective profile, but a relatively high number of thromboembolic events (TEEs) have been reported with such treatment. We aimed to evaluate the incidence and management of TEEs and possible predictive factors related to WEB embolization of ruptured and unruptured intracranial aneurysms. METHODS A single-center database with consecutive aneurysms treated with a WEB device between July 2012 and May 2022 was reviewed for intraoperative and delayed TEEs. Univariate and multivariable analyses were used to determine factors associated with TEEs. RESULTS A total of 266 independent aneurysms were treated with WEB devices in 245 patients (mean age 55.78 ± 11.64 years, 169 (63.5%) females, 80 (30%) ruptured). The overall rate of TEEs is 13% (35/266), including 8.7% intraoperative. Symptomatic TEEs with clinical sequelae at a 3-month follow-up are reported to be 2.6% (7/266) with no TEE-related mortality. Both the replacement of a WEB device during the procedure (adjusted odds ratio = 2.61, 95% CI 1.24-5.49; P = .01) and ruptured aneurysms (adjusted odds ratio = 2.74, 95% CI 1.31-5.7; P = .007) were independent predictors of TEEs. A case-by-case management of intraprocedural TEE is also presented; tirofiban was successfully used in most cases of this cohort. CONCLUSION In this study, we demonstrated that ruptured aneurysms and WEB device replacement during the procedure were independent predictive factors for TEEs. As a result, making the correct choice of WEB is crucial for improving treatment outcomes. Moreover, with proper medical management of TEEs, minimal morbidity and no mortality could be achieved, which reinforces the safety of the technique.
Collapse
Affiliation(s)
- Fernanda Rodriguez-Erazú
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
- Department of Neurological Surgery, University Hospital Dr Manuel Quintela, Montevideo , Uruguay
| | - Jonathan Cortese
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
- Paris-Saclay University, Faculty of Medicine, INSERM U1195, Paris , France
| | - Cristian Mihalea
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
| | - Adrian Popica
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
| | - Vanessa Chalumeau
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
| | - Natalia Vasconcellos
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
| | - Sophie Gallas
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
| | - Leon Ikka
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
| | - Lamiae Grimaldi
- Clinical Research Unit AP-HP Paris-Saclay, Université de Versailles Saint-Quentin-en-Yvelines, UFR des sciences de la santé Simone Veil, Montigny-Le-Bretonneux , France
- CESP Anti-Infective Evasion and Pharmacoepidemiology Team, INSERM, Paris , France
| | - Jildaz Caroff
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
- Paris-Saclay University, Faculty of Medicine, INSERM U1176, Paris , France
| | - Laurent Spelle
- Department of Interventional Neuroradiology, Bicêtre University Hospital, Paris , France
- Paris-Saclay University, Faculty of Medicine, INSERM U1195, Paris , France
| |
Collapse
|
8
|
Fiorella D, Molyneux A, Coon A, Szikora I, Saatci I, Baltacioglu F, Aziz-Sultan MA, Hoit D, Delgado Almandoz JE, Elijovich L, Cekirge HS, Byrne J, Klisch J, Arthur AS. Safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide necked bifurcation aneurysms: final 5 year results of the pivotal WEB Intra-saccular Therapy study (WEB-IT). J Neurointerv Surg 2023; 15:1175-1180. [PMID: 37355252 PMCID: PMC10715507 DOI: 10.1136/jnis-2023-020611] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 05/31/2023] [Indexed: 06/26/2023]
Abstract
INTRODUCTION The US Woven EndoBridge Intra-saccular Therapy (WEB-IT) study is a pivotal, prospective, single arm, investigational device exemption study to evaluate the safety and effectiveness of the WEB device for the treatment of wide neck bifurcation aneurysms (WNBAs). We present complete 5 year data for the cohort of 150 patients. METHODS 150 patients with WNBAs were enrolled at 21 US and six international centers. Imaging from the index procedure, 6 month, 1 year, 3 year, and 5 year follow-up were reviewed by a core laboratory. Adverse events were reviewed and adjudicated by a clinical events adjudicator. RESULTS 83 patients had 5 year follow-up imaging and 123 had clinical follow-up. No ruptured (0/9) or unruptured aneurysm (0/141) rebled or bled during follow-up. No new device or procedure related adverse events or serious adverse events were reported after 1 year. At 5 years, using the LOCF method, complete occlusion was observed in 58.1% and adequate occlusion in 87.2% of patients. For patients with both 1 year and 5 year occlusion statuses available, 76.8% (63/82) of aneurysms remained stable or improved with no retreatment. After 1 year, 18 aneurysms were retreated, 11 of which were adequately occluded at 1 year, and 15 of which were retreated in the absence of any deterioration in occlusion grade. CONCLUSIONS Five year follow-up data from the WEB-IT study demonstrated that the WEB device was safe and effective when used in the treatment of WNBAs. Aneurysm occlusion rates achieved at 1 year follow-up were durable, with rates of progressive thrombosis far exceeding rates of recurrence over time.
Collapse
Affiliation(s)
- David Fiorella
- Department of Neurosurgery, State University of New York at Stony Brook, Stony Brook, New York, USA
| | - Andy Molyneux
- Neurovascular and Neuroradiology Research Unit, Oxford University, Oxford, UK
| | - Alex Coon
- Carondelet Medical Group, Tucson, Arizona, USA
| | - Istvan Szikora
- Neurointerventions, National Institute of Neurosciences, Budapest, Hungary
| | | | | | | | - Daniel Hoit
- Neurosurgery, University of Tennessee, Memphis, Tennessee, USA
| | | | - Lucas Elijovich
- Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA
| | - H Saruhan Cekirge
- Radiology, Private American Hospital, Ankara, Turkey
- Private Office, Saruhan Cekirge, Ankara, Turkey
| | - James Byrne
- Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Joachim Klisch
- Neuroradiology, HELIOS Klinikum Erfurt, Erfurt, Thüringen, Germany
| | - Adam S Arthur
- Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA
- Neurosurgery, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| |
Collapse
|
9
|
Abouei Mehrizi MA, Habibi MA, Keykhosravi E, Eazi SM, Minaee P, Mirjani MS. The Safety and Efficacy of eCLIPs for Treatment of Wide-Necked Bifurcation Aneurysms: A Systematic Review and Meta-Analysis. World Neurosurg 2023; 180:213-223.e7. [PMID: 37813336 DOI: 10.1016/j.wneu.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/01/2023] [Accepted: 10/03/2023] [Indexed: 10/11/2023]
Abstract
BACKGROUND Wide-necked bifurcation aneurysms (WNBAs) are challenging intracranial aneurysms. Several device and treatment approaches have been proposed for the treatment of WNBAs. The endovascular clip system (eCLIPs) is a newly developed endovascular device with flow diverter and flow disruptor features. This study aims to investigate the safety and efficacy of the eCLIPs for treatment of patients with WNBAs. METHODS This is a systematic review and meta-analysis study conducted in accordance with the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines. The electronic databases of PubMed, Embase, Scopus, and Web of Science were systematically reviewed from inception to June 19, 2023. The rate of complete and near-complete occlusion, successful device implantation, and serious adverse events were pooled using STATA, version 17. RESULTS A total of 5 studies with 110 patients with WNBAs were systematically investigated. Our findings show that the immediate successful implantation rate of eCLIPs was 0.93 (95% confidence interval [CI], 0.88-0.97). Moreover, the immediate postoperative complete occlusion rate was 0.34 (95% CI, 0.10-0.58), and the immediate postoperative near-complete occlusion rate was 0.35 (95% CI, 0.24-0.45). Also, the near-complete occlusion rate at the latest follow-up was 0.3 (95% CI, 0.16-0.44). The serious adverse event rate was 0.14 (95% CI, 0.05-0.22). Stroke was also reported in 2 studies, with 1 study reporting 1 patient who experienced stroke within the first 24 hours and 1 study reporting no patients with stroke. CONCLUSIONS Our findings document that the eCLIPs is a safe and effective device for treating patients with WNBAs and associated with favorable outcomes.
Collapse
Affiliation(s)
| | - Mohammad Amin Habibi
- Skull Base Research Center, Loghman Hakim Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| | - Ehsan Keykhosravi
- Department of Neurosurgery, Faculty of Medicine, Mashhad University of Medical Science, Mashhad, Iran
| | - Seyed Mohammad Eazi
- Clinical Research Development Center, Qom University of Medical Sciences, Qom, Iran
| | - Poriya Minaee
- Clinical Research Development Center, Qom University of Medical Sciences, Qom, Iran
| | | |
Collapse
|
10
|
Saigal K, Patel AB, Lucke-Wold B. Artificial Intelligence and Neurosurgery: Tracking Antiplatelet Response Patterns for Endovascular Intervention. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1714. [PMID: 37893432 PMCID: PMC10608122 DOI: 10.3390/medicina59101714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/22/2023] [Accepted: 09/22/2023] [Indexed: 10/29/2023]
Abstract
Platelets play a critical role in blood clotting and the development of arterial blockages. Antiplatelet therapy is vital for preventing recurring events in conditions like coronary artery disease and strokes. However, there is a lack of comprehensive guidelines for using antiplatelet agents in elective neurosurgery. Continuing therapy during surgery poses a bleeding risk, while discontinuing it before surgery increases the risk of thrombosis. Discontinuation is recommended in neurosurgical settings but carries an elevated risk of ischemic events. Conversely, maintaining antithrombotic therapy may increase bleeding and the need for transfusions, leading to a poor prognosis. Artificial intelligence (AI) holds promise in making difficult decisions regarding antiplatelet therapy. This paper discusses current clinical guidelines and supported regimens for antiplatelet therapy in neurosurgery. It also explores methodologies like P2Y12 reaction units (PRU) monitoring and thromboelastography (TEG) mapping for monitoring the use of antiplatelet regimens as well as their limitations. The paper explores the potential of AI to overcome such limitations associated with PRU monitoring and TEG mapping. It highlights various studies in the field of cardiovascular and neuroendovascular surgery which use AI prediction models to forecast adverse outcomes such as ischemia and bleeding, offering assistance in decision-making for antiplatelet therapy. In addition, the use of AI to improve patient adherence to antiplatelet regimens is also considered. Overall, this research aims to provide insights into the use of antiplatelet therapy and the role of AI in optimizing treatment plans in neurosurgical settings.
Collapse
Affiliation(s)
- Khushi Saigal
- College of Medicine, University of Florida, Gainesville, FL 32610, USA
| | - Anmol Bharat Patel
- College of Medicine, University of Miami—Miller School of Medicine, Miami, FL 33136, USA;
| | - Brandon Lucke-Wold
- Department of Neurosurgery, University of Florida, Gainesville, FL 32608, USA
| |
Collapse
|
11
|
Biondi A, Primikiris P, Vitale G, Charbonnier G. Endosaccular flow disruption with the Contour Neurovascular System: angiographic and clinical results in a single-center study of 60 unruptured intracranial aneurysms. J Neurointerv Surg 2023; 15:838-843. [PMID: 35995545 DOI: 10.1136/jnis-2022-019271] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 08/06/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND The Contour Neurovascular System is a novel device designed to treat intracranial aneurysms by intrasaccular flow disruption. We report our experience and mid-term follow-up in a series of patients treated with the Contour. METHODS The patients were divided into an intention to treat and a per protocol population, the latter defined by the successful implantation of the Contour device. The intention to treat population included 53 patients (30 women, mean age 56 years) with 60 unruptured intracranial aneurysms (53 in the anterior circulation and seven in the posterior circulation). There was clinical and angiographic follow-up immediate postoperatively and at 24 hours, 3 months and 1 year using the Raymond-Roy classification and the O'Kelly-Marotta grading scale. RESULTS The Contour was successfully implanted in 54/60 (90%) aneurysms. With regard to the angiographic follow-up, there was adequate occlusion (defined as complete occlusion or presence of a neck remnant) in 31.5% of 54 aneurysms immediately postoperatively, 62.3% (in 53/54 aneurysms) at 24 hours, 81.4% (in 43/54 aneurysms) at 3 months, and 89.3% (in 28/54 aneurysms) at 1 year. Technical complications in 60 aneurysms of the intention to treat population included two (3.3%) inadvertent detachments of the device. Thromboembolic events were observed in four of the 60 aneurysms (6.7%), with no clinical symptoms in three patients and transient morbidity in one (1.7%). No aneurysm bleeding was observed and no patient was retreated during the 1-year follow-up period. There was no permanent morbidity or mortality. CONCLUSIONS The Contour device is effective and safe in the treatment of intracranial aneurysms. However, more experience and long-term follow-up are needed.
Collapse
Affiliation(s)
- Alessandra Biondi
- Department of Interventional Neuroradiology, University Hospital Centre Besancon, Besancon, France
- Laboratoire de Recherches Intégratives en Neurosciences et Psychologie Cognitive - UR 481, Université de Franche-Comté, Besancon, France
| | - Panagiotis Primikiris
- Department of Interventional Neuroradiology, University Hospital Centre Besancon, Besancon, France
| | - Giovanni Vitale
- Department of Interventional Neuroradiology, University Hospital Centre Besancon, Besancon, France
| | - Guillaume Charbonnier
- Department of Interventional Neuroradiology, University Hospital Centre Besancon, Besancon, France
- Laboratoire de Recherches Intégratives en Neurosciences et Psychologie Cognitive - UR 481, Université de Franche-Comté, Besancon, France
| |
Collapse
|
12
|
Delgado Almandoz JE, Kayan Y, Copelan AZ, Ertelt AM, Scholz JM. Lateral Compression is the Strongest Independent Predictor of Aneurysm Occlusion After Endovascular Treatment of Intracranial Aneurysms With the Woven EndoBridge Device. NEUROSURGERY PRACTICE 2023; 4:e00054. [PMID: 39958791 PMCID: PMC11810027 DOI: 10.1227/neuprac.0000000000000054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 06/01/2023] [Indexed: 02/18/2025]
Abstract
BACKGROUND AND OBJECTIVES The effect of lateral compression (LC) of the Woven EndoBridge (WEB) device on intracranial aneurysm (IA) occlusion and retreatment has not been studied in depth. This study aims to determine the effect of LC on aneurysm occlusion and retreatment after endovascular treatment with WEB. METHODS We retrospectively reviewed IAs treated with WEB at our institution between February 5th, 2019, and March 31st, 2022. LC was determined in the immediate postdetachment angiogram by measuring the mean implanted WEB width at the equator in two orthogonal projections and subtracting it from the nominal WEB width. LC was then converted to the percentage of nominal WEB width (percent LC [%LC]). Independent predictors of complete and adequate aneurysm occlusion at follow-up and retreatment were determined using multivariate logistic regression analysis. Optimal %LC thresholds were determined using receiver operating characteristic analysis. RESULTS One hundred and fifty-five IAs were included, with a mean size of 6.4 mm, a mean neck of 3.6 mm, and a mean time to last follow-up of 15.5 months. At last follow-up, complete and adequate aneurysm occlusion was present in 98 (63.2%) and 139 (89.7%) IAs, respectively. Twelve IAs were retreated (7.7%). %LC was the strongest independent predictor of complete and adequate aneurysm occlusion at first and last follow-up and an independent predictor of aneurysm retreatment. Optimal %LC thresholds for complete and adequate aneurysm occlusion at first follow-up were >17.1% and >15.7%, respectively. Compared with IAs in which these thresholds were not attained, IAs in which these thresholds were attained had significantly higher rates of complete (31% vs 68%, P-value <.0001) and adequate occlusion (81% vs 96%, P-value .004) at first follow-up. The optimal %LC threshold for aneurysm retreatment was ≤15.6%. IAs with ≤15.6% LC had a significantly higher rate of retreatment (15%) than IAs with >15.6% LC (4%, P-value .025). CONCLUSION LC is the strongest independent predictor of aneurysm occlusion in IAs treated with WEB.
Collapse
Affiliation(s)
| | - Yasha Kayan
- Neurointerventional Radiology, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA
| | - Alexander Z. Copelan
- Neurointerventional Radiology, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA
| | - Ashley M. Ertelt
- Neurointerventional Radiology, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA
| | - Jill M. Scholz
- Neurointerventional Radiology, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA
| |
Collapse
|
13
|
Aquarius R, Elbertsen D, de Vries J, Boogaarts HD, Wever KE. A systematic review of the Woven EndoBridge device-do findings in pre-clinical animal models compare to clinical results? Acta Neurochir (Wien) 2023:10.1007/s00701-023-05638-y. [PMID: 37289301 DOI: 10.1007/s00701-023-05638-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 05/13/2023] [Indexed: 06/09/2023]
Abstract
BACKGROUND The Woven Endobridge (WEB) is designed to treat intracranial wide-neck bifurcation aneurysms, preventing subarachnoid hemorrhage. The translational value of animal models used for WEB device testing is unknown. With this systematic review, we aim to identify the existing animal models used in testing the WEB device and compare the efficacy and safety outcomes to those of prospective clinical studies. METHODS This study was funded by ZonMw: project number 114024133. A comprehensive search was performed in PubMed and in EMBASE via the Ovid interface. The following exclusion criteria were used: 1) not an original full-length research paper, 2) not an in vivo animal study or a human study, 3) no WEB implantation, 4) if in humans: not a prospective study. The SYRCLE risk of bias tool (animal studies) and the Newcastle-Ottawa quality assessment scale for cohort studies (clinical studies) were used to assess risks of bias. A narrative synthesis was performed. RESULTS Six animal studies and 17 clinical studies met the inclusion criteria. The rabbit elastase aneurysm model was the only animal model used to assess WEB device performance. Safety outcomes were never reported in animal studies. Efficacy outcomes were more heterogeneous in animal studies than in clinical studies, which could be due to limited external validity of the animal models in terms of aneurysm induction and dimensions. Both animal and clinical studies were predominantly single-arm studies, and were at unclear risk of several types of bias. CONCLUSIONS The rabbit elastase aneurysm model was the only pre-clinical animal model used to assess WEB device performance. Safety outcomes were not evaluated in animal studies and could therefore not be compared to clinical outcomes. Efficacy outcomes were more heterogeneous in animal studies than in clinical studies. Future research should focus on improving methodology and reporting in order to draw accurate conclusions on the performance of the WEB device.
Collapse
Affiliation(s)
- René Aquarius
- Department of Neurosurgery, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA, Nijmegen, Gelderland, The Netherlands.
| | - Danique Elbertsen
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Center, Nijmegen, Gelderland, The Netherlands
| | - Joost de Vries
- Department of Neurosurgery, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA, Nijmegen, Gelderland, The Netherlands
| | - Hieronymus D Boogaarts
- Department of Neurosurgery, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525GA, Nijmegen, Gelderland, The Netherlands
| | - Kimberley E Wever
- Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Center, Nijmegen, Gelderland, The Netherlands
| |
Collapse
|
14
|
Kashkoush A, El-Abtah ME, Srivatsa S, Desai A, Davison M, Achey R, Mahapatra A, Patterson T, Moore N, Bain M. Comparative effectiveness of stent-assisted coiling and Woven EndoBridge embolization for the treatment of unruptured wide-neck bifurcation intracranial aneurysms. J Neurosurg 2023; 138:1487-1493. [PMID: 36334292 DOI: 10.3171/2022.10.jns221138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 10/04/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Woven EndoBridge (WEB) intrasaccular flow disruptors and stent-assisted coiling (SAC) are viable endovascular treatment options for wide-neck bifurcation intracranial aneurysms (WNBAs). Data directly comparing these two treatment options are limited. The authors aimed to compare radiographic occlusion rates and complication profiles between patients who received WEB and those who received SAC for WNBAs. METHODS Retrospective review of a prospectively maintained cerebrovascular procedural database was performed at a single academic medical center between 2017 and 2021. Patients were included if they underwent WEB embolization or SAC of an unruptured WNBA. SAC patients were propensity matched to WEB-embolized patients on the basis of aneurysm morphology. Complete and adequate (complete occlusion or residual neck remnant) occlusion rates at last angiographic follow-up, as well as periprocedural complications, were compared between the two groups. A cost comparison was performed for a typical 5-mm WNBA treated with WEB versus SAC by using manufacturer-suggested retail prices. RESULTS Thirty-five WEB and 70 SAC patients were included. Aneurysm width, neck size, and dome-to-neck ratio were comparable between groups. Follow-up duration was significantly longer in the SAC group (median [interquartile range] 545 [202-834] days vs 228 [177-494] days, p < 0.001, Mann-Whitney U-test). Complete (66% of WEB patients vs 69% of SAC patients) and adequate (94% WEB vs 91% SAC) occlusion rates were similar between groups at the last available angiographic follow-up (p = 0.744, chi-square test). Complete occlusion rates were comparable on Cox regression analysis after correction for follow-up duration (hazard ratio 1.5, 95% CI 0.8-3.1). Average time to residual aneurysm or neck formation was not statistically different between treatment groups (613 days for SAC patients vs 347 days for WEB patients, p = 0.225, log-rank test). Periprocedural complications trended higher in the SAC group (0% WEB vs 9% SAC, p = 0.175, Fisher exact test), although this finding was not significant. The equipment costs for a typical SAC case were estimated at $18,950, whereas the costs for a typical WEB device case were estimated at $18,630. CONCLUSIONS Midterm complete and adequate occlusion rates were similar between patients treated with WEB and those treated with SAC. Given these comparable outcomes, there may be equipoise in treatment options for WNBAs.
Collapse
Affiliation(s)
- Ahmed Kashkoush
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | | | - Shaarada Srivatsa
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | - Ansh Desai
- 2Case Western Reserve University School of Medicine, Cleveland, Ohio
| | - Mark Davison
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | - Rebecca Achey
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | - Ashutosh Mahapatra
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | - Thomas Patterson
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | - Nina Moore
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| | - Mark Bain
- 1Department of Neurological Surgery, Cleveland Clinic Foundation, Cleveland; and
| |
Collapse
|
15
|
Mostafa K, Bueno Neves F, Gärtner F, Peters S, Hensler J, Larsen N, Klintz T, Mahnke J, Jansen O, Wodarg F. Contour device implantation versus coil embolization for treatment of narrow neck intracranial aneurysms. Sci Rep 2023; 13:4904. [PMID: 36966218 PMCID: PMC10039918 DOI: 10.1038/s41598-023-31877-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/20/2023] [Indexed: 03/27/2023] Open
Abstract
The novel Contour device is an intrasaccular flow disruption device designed for treatment of intracranial wide-neck bifurcation aneurysms. Outside its original purpose, Contour implantation can be used to treat aneurysms with a higher dome-to-neck ratio which would be suitable for conventional unassisted coil embolization. We compared both techniques in a retrospective single-center analysis. A total of 42 aneurysms from 42 patients with a dome-to-neck ratio of 1.6 or higher were included in this study. Data on technical success, implantation times, radiation dosages, procedural complications, reinterventions and recurrences were gathered and compared. Technical success was achieved in all cases with both techniques. Aneurysm embolization was achieved significantly faster in the Contour group compared to coiling (Overall p = 0.0002; r = 0.580; acute setting: p = 0.005, r = 0.531; elective setting: p = 0.002, r = 0.607). Significantly less radiation dosage was applied in the Contour group (Overall p = 0.002; r = 0.478; acute group p = 0.006; r = 0.552; elective group p = 0.045; r = 0.397). The number of complications was higher in the coiling group compared to the Contour group (Coiling 7/21 (33,3%); Contour 3/21 (14.3%). There was a higher rate of reinterventions in the coiling group (7.6% vs 21.4%). Outside its original intention, the Contour device seems to be a safe and fast alternative to coil embolization for the treatment of narrow-neck-aneurysms.
Collapse
Affiliation(s)
- Karim Mostafa
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany.
| | - Fernando Bueno Neves
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Friederike Gärtner
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Sönke Peters
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Johannes Hensler
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Naomi Larsen
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Tristan Klintz
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Justus Mahnke
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Olav Jansen
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| | - Fritz Wodarg
- Department for Radiology and Neuroradiology, Universityhospital Schleswig Holstein (UKSH), Kiel University, Campus Kiel, Arnold-Heller-Street 3, Building D, 24105, Kiel, Germany
| |
Collapse
|
16
|
Lee KB, Suh CH, Song Y, Kwon B, Kim MH, Yoon JT, Lee DH. Trends of Expanding Indications of Woven EndoBridge Devices for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-analysis. Clin Neuroradiol 2023; 33:227-235. [PMID: 36036257 DOI: 10.1007/s00062-022-01207-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 07/20/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE Woven EndoBridge (WEB) was introduced for the endovascular therapy of wide-neck intracranial aneurysms. The safety and efficacy have been evaluated through several meta-analyses. However, these reviews did not cover the expanding indications in detail. Therefore, we aimed to show the changing trends for intracranial aneurysm treatment using the WEB device. METHODS A systematic review and meta-analysis was conducted with PubMed, Embase, and Cochrane databases. We searched for studies that reported baseline characteristics of aneurysms and the WEB devices, which had treated more than 20 aneurysms consecutively. The pooled proportions of aneurysm indications and used WEB device types were obtained. To evaluate the changing indications for the treated aneurysm size, including the neck diameter, a trend line and linear regression model was measured. RESULTS A total of 27 cohorts were included encompassing 1831 aneurysms treated with the WEB. A total of 86% were used in the four major locations as on-label indications (middle cerebral artery bifurcation; 34%, anterior communicating artery; 26%, basilar tip; 18%, internal carotid artery terminus; 7%). Among off-label indications, the most common location was the posterior communicating artery (8%), followed by the anterior cerebral artery including the pericallosal artery (6%). The median aneurysm size and neck diameter was 7 mm and 4.6 mm, respectively. The WEB device has been used for the treatment of smaller aneurysms than the initial indication. Also, the proportion for ruptured aneurysm treatment was increased up to 15%. CONCLUSION The mechanical and technical development of the WEB resulted in expanding the indications for the treatment of intracranial aneurysms. The off-label indications accounted for 14% in total and an increasing number of small aneurysms are treated with WEB devices. Moreover, the proportion for ruptured aneurysm treatment was currently increased up to 14% more than in the beginning.
Collapse
Affiliation(s)
- Ki Baek Lee
- Department of Radiologic Technology, Chungbuk Health & Science University, Cheongju, Korea (Republic of)
| | - Chong Hyun Suh
- Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Korea (Republic of)
| | - Yunsun Song
- Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Korea (Republic of)
| | - Boseong Kwon
- Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Korea (Republic of)
| | - Mi Hyeon Kim
- Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Korea (Republic of)
| | - Jong-Tae Yoon
- Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Korea (Republic of)
| | - Deok Hee Lee
- Department of Radiology, Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, 05505, Seoul, Korea (Republic of).
| |
Collapse
|
17
|
Simgen A, Weyrich A, Dietrich P, Roumia S, Mühl-Benninghaus R, Yilmaz U, Reith W, Kettner M. Treatment of Wide-Necked Cerebral Aneurysms Using the WEB Device Including Flow Alteration Assessment With Color-Coded Imaging: A Single Center Experience. World Neurosurg X 2022; 17:100143. [PMCID: PMC9626383 DOI: 10.1016/j.wnsx.2022.100143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/27/2022] [Indexed: 11/05/2022] Open
Abstract
Objective The Woven EndoBridge (WEB) device (MicroVention, Tustin, CA) has extended the treatment of cerebral aneurysms. Despite the fact that the WEB device has shown promising clinical results, little is known about the caused intra-aneurysmal flow alterations. Here we present our clinical experience with the WEB, including examining various syngo iFlow (Siemens AG, Erlangen, Germany) parameters to predict aneurysm occlusion. Methods We reviewed the data from patients with unruptured cerebral aneurysms treated with a WEB device between 2016 and 2020. Aneurysm occlusion and complications were assessed. Furthermore, different quantitative criteria were evaluated using syngo iFlow after digital subtraction angiography. Results A total of 26 patients hosting 26 cerebral aneurysms met the inclusion criteria. Follow-up was available for 21 patients, with a mean of 7.3 ± 6.3 months. A total of 71.4% (n = 15) of the aneurysms included were located in the anterior and 28.6% (n = 6) in the posterior circulation. Adequate aneurysm occlusion was achieved in 85.7% (n = 18). The iFlow parameters for reduced aneurysm outflow (ID-R) differed significantly from the parameters for reduced inflow (PI-R and PI-D) (P < 0.001). The parameters did not differ significantly between adequately and insufficiently occluded aneurysms. Only a trend towards a lower ID-R of insufficiently occluded aneurysms was observed (P = 0.063), indicating a potential predictive value for insufficient aneurysmal outflow. There was no treatment-related morbidity or mortality. Conclusions The applied syngo iFlow parameters confirmed that flow changes induced by the WEB device significantly affect outflow compared to inflow and have potential predictive value for adequate aneurysm occlusion.
Collapse
Key Words
- cerebral aneurysm
- syngo iflow
- web
- 2d, 2-dimensional
- boss, beaujon occlusion scale score
- cfd, computational fluid dynamics
- dsa, digital subtraction angiography
- id, intensity decrease
- id-r, intensity decrease ratio
- mrs, modified rankin scale
- pi, peak intensity
- pi-d, peak intensity delay
- pi-r, peak intensity ratio
- roi, region of interest
- tdc, time density curve
- ttp, time to peak
- web, woven endobridge
Collapse
Affiliation(s)
- Andreas Simgen
- To whom correspondence should be addressed: Andreas Simgen, M.D., Ph.D.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Spelle L, Herbreteau D, Caroff J, Barreau X, Ferré JC, Fiehler J, Januel AC, Costalat V, Liebig T, Bourcier R, Möhlenbruch MA, Berkefeld J, Weber W, Mihalea C, Ikka L, Ozanne A, Cognard C, Narata AP, Bibi RE, Gauvrit JY, Raoult H, Velasco S, Buhk JH, Chalumeau V, Bester M, Desal H, du Mesnil de Rochemont R, Bohner G, Fischer S, Gallas S, Biondi A, Grimaldi L, Moret J, Byrne J, Pierot L. CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS): 12-month angiographic results of a multicenter study. J Neurointerv Surg 2022:neurintsurg-2022-018749. [PMID: 35882550 DOI: 10.1136/neurintsurg-2022-018749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Accepted: 05/19/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND The CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS) study has shown that the endovascular treatment of ruptured bifurcation aneurysms with the Woven EndoBridge (WEB) is safe and effective and provides protection against rebleeding at 1 month and 1 year. The 12-month angiographic follow-up is an important endpoint of the study. METHODS The CLARYS study is a prospective multicenter study conducted in 13 European centers. The study enrolled 60 patients with 60 ruptured aneurysms of the anterior and posterior circulation. The study was conducted with an independent assessment of safety outcomes and imaging. RESULTS Sixty patients with 60 ruptured bifurcation aneurysms to be treated with the WEB were included. Fifty-three aneurysms (88.3%) had a broad base with a dome to neck ratio <2 (mean 1.6). Of these, 46 patients were evaluated by an independent core laboratory with follow-up imaging performed at 12 months or before eventual retreatment. At 1 year, 19/46 aneurysms (41.3%) were completely occluded (Raymond-Roy grade I), 21/46 (45.7%) had a residual neck and 6/46 (13.0%) had residual aneurysm filling. Adequate occlusion was reported in 40/46 (87%) aneurysms. Six patients underwent target aneurysm retreatment. CONCLUSIONS The CLARYS study has previously shown that the use of the WEB in the endovascular treatment of ruptured bifurcation aneurysms provides effective protection against rebleeding with a good safety profile. The angiographic occlusion rates at 1 year reported here are comparable to those already seen in previous multicenter studies which primarily included unruptured aneurysms.
Collapse
Affiliation(s)
- Laurent Spelle
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France .,Paris-Saclay University Faculty of Medicine, Le Kremlin-Bicetre, France
| | - Denis Herbreteau
- Department of Interventional Neuroradiology, Regional University Hospital, Tours, France
| | - Jildaz Caroff
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Assistance Publique - Hopitaux de Paris, Paris, France
| | - Xavier Barreau
- Department of Neuroradiology, Pellegrin University Hospital, Bordeaux, France
| | | | - Jens Fiehler
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Anne-Christine Januel
- Department of Diagnostic and Therapeutic Neuroradiology, Hôpital Pierre Paul Riquet, Toulouse, France
| | - Vincent Costalat
- Department of Neuroradiology, Hôpital Gui de Chauliac, Montpellier, France
| | - Thomas Liebig
- Department of Neuroradiology, Ludwig Maximilians University, Munich Faculty of Medicine, Munchen, Germany
| | - Romain Bourcier
- Department of Neuroradiology, Regional University Hospital, Nantes, France
| | - Markus A Möhlenbruch
- Department of Neuroradiology, UniversitätsKlinikum Heidelberg, Heidelberg, Germany
| | - Joachim Berkefeld
- Institut für Neuroradiologie, Klinikum der Johann Wolfgang Goethe-Universität Frankfurt, Frankfurt am Main, Germany
| | - Werner Weber
- Department of Neuroradiology, Ruhr-Universitat Bochum Medizinische Fakultat, Bochum, Germany
| | - Cristian Mihalea
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Assistance Publique - Hopitaux de Paris, Paris, France
| | - Léon Ikka
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Assistance Publique - Hopitaux de Paris, Paris, France
| | - Augustin Ozanne
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Assistance Publique - Hopitaux de Paris, Paris, France
| | - Christophe Cognard
- Department of Diagnostic and Therapeutic Neuroradiology, Hôpital Pierre Paul Riquet, Toulouse, France
| | - Ana Paula Narata
- Department of Interventional Neuroradiology, Regional University Hospital, Tours, France
| | - Richard Edwige Bibi
- Department of Interventional Neuroradiology, Regional University Hospital, Tours, France
| | - Jean-Yves Gauvrit
- Department of Neuroradiology, Regional University Hospital, Rennes, France
| | - Hélène Raoult
- Department of Neuroradiology, Regional University Hospital, Rennes, France
| | - Stéphane Velasco
- Department of Radiology, Regional University Hospital, Poitiers, France
| | - Jan-Hendrik Buhk
- Department of Neuroradiology, Asklepios Hospital Group, Hamburg, Germany
| | - Vanessa Chalumeau
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Assistance Publique - Hopitaux de Paris, Paris, France
| | - Maxim Bester
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Hubert Desal
- Department of Neuroradiology, Regional University Hospital, Nantes, France
| | | | - Georg Bohner
- Neuroradiology, Charite Universitatsmedizin, Berlin, Germany
| | - Sebastian Fischer
- Department of Neuroradiology, Ruhr-Universitat Bochum Medizinische Fakultat, Bochum, Germany
| | - Sophie Gallas
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Assistance Publique - Hopitaux de Paris, Paris, France
| | - Alessandra Biondi
- Department of Neuroradiology and Endovascular Therapy, Jean Minjoz University Hospital, Besancon, France
| | - Lamiae Grimaldi
- Clinical Research Unit AP-HP, Paris-Saclay University Faculty of Medicine, Le Kremlin-Bicetre, France.,CESP Anti-Infective Evasion and Pharmacoepidemiology Team, Université de Versailles Saint-Quentin-en-Yvelines UFR des Sciences de la Santé Simone Veil, Montigny-Le-Bretonneux, France
| | - Jacques Moret
- NEURI Brain Vascular Center, Interventional Neuroradiology, Bicetre University Hospital, Le Kremlin-Bicetre, France.,Paris-Saclay University Faculty of Medicine, Le Kremlin-Bicetre, France
| | - James Byrne
- Department of Neuroradiology, Oxford Radcliffe Hospitals NHS Trust, Oxford, UK
| | - Laurent Pierot
- Department of Neuroradiology, Hôpital Maison Blanche, Reims, France.,Champagne-Ardenne University, Reims, France
| |
Collapse
|
19
|
Pierot L, Szikora I, Barreau X, Holtmannspoetter M, Spelle L, Klisch J, Herbreteau D, Costalat V, Fiehler J, Januel AC, Liebig T, Stockx L, Weber W, Berkefeld J, Moret J, Molyneux A, Byrne J. Aneurysm treatment with the Woven EndoBridge (WEB) device in the combined population of two prospective, multicenter series: 5-year follow-up. J Neurointerv Surg 2022; 15:552-557. [PMID: 35803731 DOI: 10.1136/neurintsurg-2021-018414] [Citation(s) in RCA: 57] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/28/2022] [Indexed: 02/03/2023]
Abstract
BACKGROUND Evaluating a new endovascular treatment for intracranial aneurysms must not only demonstrate short-term safety and efficacy, but also evaluate longer-term outcomes (eg, delayed complications, anatomical results, retreatment). The current analysis reports the 5-year clinical and anatomical results of Woven EndoBridge (WEB) treatment in two European combined trial populations (WEBCAST (WEB Clinical Assessment of Intrasaccular Aneurysm Therapy) and WEBCAST-2). METHODS All adverse events occurring between the procedure and 5-year follow-up were independently evaluated by an expert. Aneurysm occlusion was evaluated by an independent core laboratory using a three-grade scale: complete occlusion, neck remnant, and aneurysm remnant. In cases where data were not available at 5-year follow-up, the last observation carry forward (LOCF) method was used. RESULTS The safety and efficacy populations comprised 100 patients and 95 aneurysms, respectively. No adverse event related to the device occurred after the procedure during the 5-year follow-up period. Mortality at 5 years was 7.0% (7/100 patients) including mortality related to the WEB (0/100, 0.0%), the procedure (1/100, 1.0%), and another condition (6/100, 6.0%). At 5 years, complete aneurysm occlusion was observed in 49/95 (51.6%) aneurysms, neck remnant in 25/95 (26.3%), and aneurysm remnant in 21/95 (22.1%). Retreatment rate at 5 years was 11.6% (11/95 aneurysms). CONCLUSIONS This analysis conducted in a population of patients with wide-neck bifurcation aneurysms confirms WEB's safety profile. Additional evidence demonstrates good stability of aneurysm occlusion with adequate occlusion (complete occlusion or neck remnant) at 5 years in 77.9% of aneurysms with a low retreatment rate (11.6%). CLINICAL TRIAL REGISTRATION WEBCAST and WEBCAST-2: Unique identifier: NCT01778322.
Collapse
Affiliation(s)
- Laurent Pierot
- Department of Neuroradiology, CHU Reims, Reims, Champagne-Ardenne, France
| | - Istvan Szikora
- Neurointerventions, National Institute of Clinical Neurosciences, Budapest, Hungary
| | - Xavier Barreau
- Neuroradiology Department, CHU Bordeaux GH Pellegrin, Bordeaux, Aquitaine, France
| | - Markus Holtmannspoetter
- Interventional and Diagnostic Neuroradiology, Nuremberg Hospital Campus South, Nurnberg, Germany
| | - Laurent Spelle
- NEURI Interventional Neuroradiology, APHP, Paris, Île-de-France, France.,Neuroradiology, Paris-Saclay University Faculty of Medicine, Le Kremlin-Bicetre, France
| | - Joachim Klisch
- Neuroradiology, Helios Klinikum Erfurt, Erfurt, Thüringen, Germany
| | | | - Vincent Costalat
- Neuroradiology, CHU Montpellier, Montpellier, Languedoc-Roussillon, France
| | - Jens Fiehler
- Department of Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Thomas Liebig
- Department of Neuroradiology, University Hospital Munich, Munchen, Bayern, Germany
| | - Luc Stockx
- Neuroradiology, Ziekenhuis Oost-Limburg, Genk, Limburg, Belgium
| | - Werner Weber
- Radiology and Neuroradiology, Ruhr-Universität Bochum, Bochum, Nordrhein-Westfalen, Germany
| | - Joachim Berkefeld
- Institute of Neuroradiology, Goethe-Universitat Frankfurt am Main, Frankfurt am Main, Hessen, Germany
| | - Jacques Moret
- NEURI Interventional Neuroradiology, APHP, Paris, Île-de-France, France
| | - Andy Molyneux
- Neurovascular and Neuroradiology Research Unit, Oxford University, Oxford, UK
| | - James Byrne
- Department of Neuroradiology, Oxford University, Oxford, UK
| |
Collapse
|
20
|
Mascitelli JR, Lawton MT, Hendricks BK, Hardigan TA, Yoon JS, Yaeger KA, Kellner CP, De Leacy RA, Fifi JT, Bederson JB, Albuquerque FC, Ducruet AF, Birnbaum LA, Caron JLR, Rodriguez P, Mocco J. Endovascular Therapy Versus Microsurgical Clipping of Ruptured Wide Neck Aneurysms (EVERRUN Registry): a multicenter, prospective propensity score analysis. J Neurosurg 2022; 137:87-94. [PMID: 34740187 DOI: 10.3171/2021.7.jns211323] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 07/07/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Randomized controlled trials have demonstrated the superiority of endovascular therapy (EVT) compared to microsurgery (MS) for ruptured aneurysms suitable for treatment or when therapy is broadly offered to all presenting aneurysms; however, wide neck aneurysms (WNAs) are a challenging subset that require more advanced techniques and warrant further investigation. Herein, the authors sought to investigate a prospective, multicenter WNA registry using rigorous outcome assessments and compare EVT and MS using propensity score analysis (PSA). METHODS Untreated, ruptured, saccular WNAs were included in the analysis. A WNA was defined as having a neck ≥ 4 mm or a dome/neck ratio (DNR) < 2. The primary outcome was the modified Rankin Scale (mRS) score at 1 year posttreatment, as assessed by blinded research nurses (good outcome: mRS scores 0-2) and compared using PSA. RESULTS The analysis included 87 ruptured aneurysms: 55 in the EVT cohort and 32 in the MS cohort. Demographics were similar in the two cohorts, including Hunt and Hess grade (p = 0.144) and modified Fisher grade (p = 0.475). WNA type inclusion criteria were similar in the two cohorts, with the most common type having a DNR < 2 (EVT 60.0% vs MS 62.5%). More anterior communicating artery aneurysms (27.3% vs 18.8%) and posterior circulation aneurysms (18.2% vs 0.0%) were treated with EVT, whereas more middle cerebral artery aneurysms were treated with MS (34.4% vs 18.2%, p = 0.025). Within the EVT cohort, 43.6% underwent stand-alone coiling, 50.9% balloon-assisted coiling, 3.6% stent-assisted coiling, and 1.8% flow diversion. The 1-year mRS score was assessed in 81 patients (93.1%), and the primary outcome demonstrated no increased risk for a poor outcome with MS compared to EVT (OR 0.43, 95% CI 0.13-1.45, p = 0.177). The durability of MS was higher, as evidenced by retreatment rates of 12.7% and 0% for EVT and MS, respectively (p = 0.04). CONCLUSIONS EVT and MS had similar clinical outcomes at 1 year following ruptured WNA treatment. Because of their challenging anatomy, WNAs may represent a population in which EVT's previously demonstrated superiority for ruptured aneurysm treatment is less relevant. Further investigation into the treatment of ruptured WNAs is warranted.
Collapse
Affiliation(s)
- Justin R Mascitelli
- 1Department of Neurosurgery, University of Texas Health Science Center at San Antonio, Texas
| | - Michael T Lawton
- 2Department of Neurosurgery, Barrow Neurological Institute, Phoenix, Arizona
| | | | - Trevor A Hardigan
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| | - James S Yoon
- 4Yale School of Medicine, New Haven, Connecticut
| | - Kurt A Yaeger
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| | - Christopher P Kellner
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| | - Reade A De Leacy
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| | - Johanna T Fifi
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| | - Joshua B Bederson
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| | | | - Andrew F Ducruet
- 2Department of Neurosurgery, Barrow Neurological Institute, Phoenix, Arizona
| | - Lee A Birnbaum
- 1Department of Neurosurgery, University of Texas Health Science Center at San Antonio, Texas
| | - Jean Louis R Caron
- 1Department of Neurosurgery, University of Texas Health Science Center at San Antonio, Texas
| | - Pavel Rodriguez
- 1Department of Neurosurgery, University of Texas Health Science Center at San Antonio, Texas
| | - J Mocco
- 3Department of Neurosurgery, Icahn School of Medicine at Mount Sinai Hospital, Mount Sinai Health System, New York, New York; and
| |
Collapse
|
21
|
Simulation of intra-saccular devices for pre-operative device size selection: Method and validation for sizing and porosity simulation. Comput Biol Med 2022; 147:105744. [PMID: 35763930 DOI: 10.1016/j.compbiomed.2022.105744] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 05/24/2022] [Accepted: 06/11/2022] [Indexed: 11/24/2022]
Abstract
Intra-saccular devices (ID) are novel braided devices used for complex intracranial aneurysms treatment. Treatment success is associated with correct device size selection. A technique that predicts the ID size within the aneurysm before intervention will provide a powerful computational tool to aid the interventionist during device selection. We present a method to calculate the device's final height, radial expansion and porosity within the patient's anatomy, which allows assessing different device sizes before treatment takes place. The proposed sizing technique was tested in-vitro and in real patient's geometries obtained from 3DRA angiographic images of 8 unruptured aneurysms previously treated with IDs. The obtained simulated height was compared to the real height, with a mean error of less than 0.28 mm (±0.44). The porosity calculation method was tested in-vitro with an error of 0.02 (±0.022). The results of both sizing and porosity experiments resemble well measures from real patients. This methodology could be used before treatment to provide the interventionist with additional information that allows selecting the device that best fits the patient's aneurysm to be treated.
Collapse
|
22
|
Boulouis G, Soize S, Maus V, Fischer S, Lobsien D, Klisch J, Styczen H, Deuschl C, Abdullayev N, Kabbasch C, Kaiser D, Jamous A, Behme D, Janot K, Bellanger G, Cognard C, Pierot L, Gawlitza M. Flow diversion for internal carotid artery aneurysms with compressive neuro-ophthalmologic symptoms: clinical and anatomical results in an international multicenter study. J Neurointerv Surg 2021; 14:1090-1095. [PMID: 34795018 DOI: 10.1136/neurintsurg-2021-018188] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 10/27/2021] [Indexed: 11/04/2022]
Abstract
BACKGROUND Scientific data on the safety and efficacy of flow diverter stents (FDS) for the treatment of unruptured internal carotid artery (ICA) aneurysms with compressive neuro-ophthalmological symptoms are scarce. We studied this subject in a retrospective international multicenter series, pooling data of 9 tertiary care neurointerventional departments. OBJECTIVE To investigate, in a retrospective, multicentric cohort of patients presenting with visual or oculomotor symptoms attributed to a compressive carotid artery in an unruptured intracranial aneurysm, the safety and efficacy profiles of FDS, by analyzing neuro-opthalmologic symptom evolution following FDS placement, complications, and aneurysm obliteration rates. METHODS All patients treated since 2015 with a FDS for an unruptured aneurysm of the ICA with signs of compressive cranial nerve symptoms (CN II, III, IV, VI) were included. RESULTS We treated 55 patients with 55 aneurysms; 21 (38.2%) patients had oculomotor and 15 (27.3%) visual symptoms only; 19 (34.5%) presented with a combination of both. Treatment-related morbidity/mortality occurred in 7.2% and 3.6%, respectively. At last imaging follow-up (13.1±10.5 months) rates of complete aneurysm occlusion, neck remnant, and aneurysm remnant were 72%, 14%, and 14%, respectively. At last clinical follow-up after 13±10.5 months, 19/51 (37.3%) patients had recovered completely and 18/51 (35.3%) had recovered at least partially from their neuro-ophthalmological symptoms. In multivariable models, a longer delay between symptom onset and treatment was associated with higher odds for incomplete recovery and lower odds for any improvement (aOR 1.03 (95% CI 1.01 to 1.07), p=0.047 and 0.04 (0-0.81), p=0.020). Incomplete recovery was independently associated with older age and fusiform aneurysms. CONCLUSION FDS are effective to treat patients with compressive aneurysms of the ICA causing neuro-ophthalmological symptoms, especially when treatment is initiated early after symptom onset, and aneurysm occlusion is adequate. However, serious complications are not rare.
Collapse
Affiliation(s)
| | - Sebastien Soize
- Department of Neuroradiology, Hôpital Maison Blanche, CHU Reims, Reims, France
| | - Volker Maus
- Department of Diagnostic and Interventional Neuroradiology and Nuclear Medicine, University Hospital Knappschaftskrankenhaus Bochum,Universitätsklinik der Ruhr-Universität, Bochum, Germany
| | - Sebastian Fischer
- Department of Diagnostic and Interventional Neuroradiology and Nuclear Medicine, University Hospital Knappschaftskrankenhaus Bochum,Universitätsklinik der Ruhr-Universität, Bochum, Germany
| | - Donald Lobsien
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, HELIOS Klinikum Erfurt, Erfurt, Germany
| | - Joachim Klisch
- Institute of Diagnostic and Interventional Radiology and Neuroradiology, HELIOS Klinikum Erfurt, Erfurt, Germany
| | - Hanna Styczen
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Cornelius Deuschl
- Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
| | - Nuran Abdullayev
- Department of Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Christoph Kabbasch
- Department of Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany
| | - Daniel Kaiser
- EKFZ for Digital Health, Dresden University of Technology, Dresden, Germany.,Department of Diagnostic and Interventional Neuroradiology, University Hospital Carl Gustav Carus, Dresden, Germany
| | - Ala Jamous
- Department of Neuroradiology, University Medical Center Göttingen, Göttingen, Germany
| | - Daniel Behme
- Department of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany
| | - Kevin Janot
- Department of Neuroradiology, CHRU Tours, Tours, France
| | | | - Cristophe Cognard
- Diagnostic and Therapeutic Neuroradiology, CHU Toulouse, Toulouse, France
| | - Laurent Pierot
- Department of Neuroradiology, Hôpital Maison Blanche, CHU Reims, Reims, France
| | - Matthias Gawlitza
- EKFZ for Digital Health, Dresden University of Technology, Dresden, Germany .,Department of Diagnostic and Interventional Neuroradiology, University Hospital Carl Gustav Carus, Dresden, Germany
| | | |
Collapse
|
23
|
Pierot L. Ten Years of Clinical Evaluation of the Woven EndoBridge: A Safe and Effective Treatment for Wide-Neck Bifurcation Aneurysms. Neurointervention 2021; 16:211-221. [PMID: 34674453 PMCID: PMC8561039 DOI: 10.5469/neuroint.2021.00395] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 10/11/2021] [Indexed: 11/24/2022] Open
Abstract
Intrasaccular flow disruption is an innovative approach for the endovascular treatment of intracranial aneurysms. As of now, only one device is currently available worldwide: the Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, CA, USA). After 10 years of clinical use and careful clinical evaluation of the WEB device by multiple prospective, multicenter studies, this article is summarizing the current knowledge regarding this endovascular technique; indications, modalities, safety and efficacy of the WEB procedure are described.
Collapse
Affiliation(s)
- Laurent Pierot
- Department of Neuroradiology, Hôpital Maison-Blanche, CHU Reims, University Reims-Champagne-Ardenne, Reims, France
| |
Collapse
|
24
|
Amuluru K, Al-Mufti F, Sahlein DH, Scott J, Denardo A. Adjustment of Malpositioned Woven EndoBridge Device Using Gooseneck Snare: Complication Management Technique. Neurointervention 2021; 16:275-279. [PMID: 34634856 PMCID: PMC8561038 DOI: 10.5469/neuroint.2021.00318] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/29/2021] [Indexed: 12/25/2022] Open
Abstract
The Woven EndoBridge (WEB) is an intrasaccular flow-disrupting device for the treatment of wide-necked saccular cerebral aneurysms. As with any neuroendovascular device, complications in the form of malpositioning and migration must be managed quickly and safely. Few studies have reported complication management techniques in instances of dislocated or migrated WEB devices. We retrospectively describe a case of a malpositioned WEB device that was successfully adjusted with the use of a gooseneck snare. Multiple other intra-procedural bailout strategies for management of WEB malposition and migration were considered, and are herein discussed. Operators should be aware of the causes of WEB malposition and a variety of bailout strategies.
Collapse
Affiliation(s)
- Krishna Amuluru
- Division of Interventional Neuroradiology, Goodman Campbell Brain and Spine, Ascension St. Vincent Medical Center, Indianapolis, IN, USA
| | - Fawaz Al-Mufti
- Department of Endovascular Neurosurgery and Neurocritical Care, Westchester Medical Center, Valhalla, NY, USA
| | - Daniel H Sahlein
- Division of Interventional Neuroradiology, Goodman Campbell Brain and Spine, Ascension St. Vincent Medical Center, Indianapolis, IN, USA
| | - John Scott
- Division of Interventional Neuroradiology, Goodman Campbell Brain and Spine, Ascension St. Vincent Medical Center, Indianapolis, IN, USA
| | - Andrew Denardo
- Division of Interventional Neuroradiology, Goodman Campbell Brain and Spine, Ascension St. Vincent Medical Center, Indianapolis, IN, USA
| |
Collapse
|
25
|
De Beule T, Boulanger T, Heye S, van Rooij WJ, van Zwam W, Stockx L. The Woven EndoBridge for unruptured intracranial aneurysms: Results in 95 aneurysms from a single center. Interv Neuroradiol 2021; 27:594-601. [PMID: 33745363 PMCID: PMC8493345 DOI: 10.1177/15910199211003428] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 02/10/2021] [Accepted: 02/19/2021] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND AND PURPOSE The Woven EndoBridge (WEB) is an intrasaccular flowdisruptor that is increasingly used for the treatment of (wide-necked) aneurysms. We present our experience with the WEB for unruptured aneurysms. MATERIALS AND METHODS Between April 2014 and August 2019, 93 patients with 95 unruptured aneurysms were primarily treated with the WEB. There were 69 women and 24 men, mean age 61 years (median 58, range 37-80). RESULTS Of 95 aneurysms, 86 had been discovered incidentally, 3 were symptomatic and 6 were additional to another ruptured aneurysm. Location was anterior communicating artery 33, middle cerebral artery 29, basilar tip 19, carotid tip 8, posterior communicating artery 4, posterior inferior cerebellar artery 1, superior cerebellar artery 1. Mean aneurysm size was 6 mm (median 6, range 3-13 mm).In one aneurysm additional coils were used and in another, a stent was placed. There was one procedural rupture without clinical sequelae. There were two thrombo-embolic complications leading to permanent deficit in one patient (mRS 2). Morbidity rate was 1.0% (1 of 93, 95%CI 0.01-6.5%) and mortality was 0% (0 of 93, 95%CI 0.0-4.8%). Angiographic follow-up at six months was available in 85 patients with 87 aneurysms (91%). Of 87 aneurysms, 68 (78%) were completely occluded, 14 (16%) had a neck remnant and 5 were incompletely occluded. Four aneurysms were retreated. Retreatment rate was 4.5% (4 of 87, 95%CI 1.7-13.6%). CONCLUSION WEB treatment of unruptured aneurysms is safe and effective. Additional devices are needed only rarely and retreatment at follow-up is infrequent.
Collapse
Affiliation(s)
- Tom De Beule
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| | | | - Sam Heye
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| | | | - Wim van Zwam
- Department of Radiology, Maastricht Universiteit Medisch Centrum, Maastricht, the Netherlands
| | - Luc Stockx
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| |
Collapse
|
26
|
Rai AT, Turner RC, Brotman RG, Boo S. Comparison of operating room variables, radiation exposure and implant costs for WEB versus stent assisted coiling for treatment of wide neck bifurcation aneurysms. Interv Neuroradiol 2021; 27:465-472. [PMID: 33076746 PMCID: PMC8392778 DOI: 10.1177/1591019920965392] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND The WEB device offers another option for treating wide neck bifurcation aneurysms (WNBA). The objective was to compare procedure variables, radiation and implant cost between WEB and stent assisted coiling (SAC) for WNBA. METHODS A retrospective comparison of similarly sized WNBA treated with SAC or WEB over 5-years was performed. The operating room (arrival-departure), anesthesia (intubation-extubation), procedure duration (puncture-closure), fluoroscopy time and radiation dose(m-Gy) were recorded from the patients' charts. Implant cost per case of all implants (stents, coils, WEB) that were opened whether deployed or not was captured including any coils used in the WEB cases. The implant cost represented the true cost incurred by the institution. RESULTS There were 46 WEB and 41 SAC cases with no significant difference in aneurysm size. There were more MCA and ACOMM (p = 0.005) and more ruptured aneurysms (p = 0.02) in the WEB group. Regarding procedure variables (hours:minutes): Operating room time WEB 2:31 (±0:37) versus SAC 3:41 (±0:50) (p < 0.0001); anesthesia duration WEB 2:05 (±0:31) versus SAC 3:13 (±0:51) (p < 0.0001) and procedure duration WEB 1:16 (±0:29) versus SAC 2:09 (±0:46) (p < 0.0001). Regarding radiation: Fluoroscopy time WEB 0:34 (±0:18) versus SAC 1:06 (±0:35) (p < 0.0001) and radiation dose WEB 2392(±1086)m-Gy versus SAC 3442 (±1528)m-Gy (p = 0.0007). The implant cost was $17,028(±$5,527) for the WEB versus $23,813 (±$7,456) for the SAC group (p < 0.0001). CONCLUSION The WEB group had significantly shorter operating room, procedure and anesthesia duration compared to the SAC group. The radiation dose and fluoroscopy time was lower for the WEB group. The total implant cost per case was significantly lower for the WEB versus the SAC group.
Collapse
Affiliation(s)
- Ansaar T Rai
- Interventional Neuroradiology, Rockefeller Neuroscience Institute, West Virginia University, School of Medicine, Morgantown, WV, USA
| | - Ryan C Turner
- Neurosurgery, Rockefeller Neuroscience Institute, West Virginia University School of Medicine, Morgantown, WV, USA
| | - Ryan G Brotman
- Neuroradiology, Rockefeller Neuroscience Institute, West Virginia University School of Medicine, Morgantown, WV, USA
| | - SoHyun Boo
- Interventional Neuroradiology, Rockefeller Neuroscience Institute, West Virginia University, School of Medicine, Morgantown, WV, USA
| |
Collapse
|
27
|
Tawk RG, Hasan TF, D'Souza CE, Peel JB, Freeman WD. Diagnosis and Treatment of Unruptured Intracranial Aneurysms and Aneurysmal Subarachnoid Hemorrhage. Mayo Clin Proc 2021; 96:1970-2000. [PMID: 33992453 DOI: 10.1016/j.mayocp.2021.01.005] [Citation(s) in RCA: 95] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 12/27/2020] [Accepted: 01/12/2021] [Indexed: 12/11/2022]
Abstract
Unruptured intracranial aneurysms (UIAs) are commonly acquired vascular lesions that form an outpouching of the arterial wall due to wall thinning. The prevalence of UIAs in the general population is 3.2%. In contrast, an intracranial aneurysm may be manifested after rupture with classic presentation of a thunderclap headache suggesting aneurysmal subarachnoid hemorrhage (SAH). Previous consensus suggests that although small intracranial aneurysms (<7 mm) are less susceptible to rupture, aneurysms larger than 7 mm should be treated on a case-by-case basis with consideration of additional risk factors of aneurysmal growth and rupture. However, this distinction is outdated. The PHASES score, which comprises data pooled from several prospective studies, provides precise estimates by considering not only the aneurysm size but also other variables, such as the aneurysm location. The International Study of Unruptured Intracranial Aneurysms is the largest observational study on the natural history of UIAs, providing the foundation to the current guidelines for the management of UIAs. Although SAH accounts for only 3% of all stroke subtypes, it is associated with considerable burden of morbidity and mortality. The initial management is focused on stabilizing the patient in the intensive care unit with close hemodynamic and serial neurologic monitoring with endovascular or open surgical aneurysm treatment to prevent rebleeding. Since the results of the International Subarachnoid Aneurysm Trial, treatment of aneurysmal SAH has shifted from surgical clipping to endovascular coiling, which demonstrated higher odds of survival free of disability at 1 year after SAH. Nonetheless, aneurysmal SAH remains a public health hazard and is associated with high rates of disability and death.
Collapse
Affiliation(s)
- Rabih G Tawk
- Department of Neurologic Surgery, Mayo Clinic, Jacksonville, FL.
| | - Tasneem F Hasan
- Department of Neurology, Ochsner Louisiana State University Health Sciences Center, Shreveport
| | | | | | - William D Freeman
- Department of Neurologic Surgery, Mayo Clinic, Jacksonville, FL; Department of Neurology, Mayo Clinic, Jacksonville, FL; Department of Critical Care, Mayo Clinic, Jacksonville, FL
| |
Collapse
|
28
|
Alpay K, Nania A, Parkkola R, Downer J, Lindgren A, Rautio R. The outcomes of recurrent wide-necked intracranial aneurysms treated with the Woven EndoBridge (WEB): A retrospective bicenter study. J Neuroradiol 2021; 49:298-304. [PMID: 34090926 DOI: 10.1016/j.neurad.2021.05.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 05/26/2021] [Accepted: 05/27/2021] [Indexed: 12/12/2022]
Abstract
BACKGROUND The Woven EndoBridge (WEB) is a device for the treatment of intracranial wide-necked bifurcation aneurysms. The safety and effectiveness of WEB for intracranial aneurysms have both been evaluated in previous trials. Our aim was to study the outcomes of recurrent intracranial aneurysms (IAs) treated with WEB. METHODS Clinical and radiological outcomes of patients with a wide-necked aneurysm recurrence, which was treated with WEB device, were assessed. Imaging follow-up was performed with digital subtraction angiography and/or magnetic resonance angiography. Aneurysm occlusion was determined using by the Raymond-Roy Occlusion Classification (RROC). RROC 1 and RROC 2 were considered as adequate radiological outcome. RESULTS Twenty-two patients with 23 recurrent IAs were treated with WEB. Of which, 17 of recurrent IAs (74%) previously treated by coiling, three (13%) by clipping and three (13%) by WEB. The most common location of the recurrent IA was the middle cerebral artery (n = 10, 43%). Endovascular treatment with WEB alone was suitable for 20 recurrent IAs (87%). Ancillary devices were also used: coils in two (9%), and a stent in one (4%). Radiological follow-up results available for all patients (range: 3-60 months; median 24 months). Adequate occlusion (RROC I and II) was achieved in 20 recurrent IAs (87%). A hemorrhagic complication occurred 2 weeks post treatment in one patient (5%). CONCLUSIONS WEB could be an effective treatment with low rates of complications for challenging cases of recurrent wide-necked IAs.
Collapse
Affiliation(s)
- Kemal Alpay
- Department of Radiology, Turku University Hospital, Turku, Finland.
| | - Alberto Nania
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, United Kingdom
| | - Riitta Parkkola
- Department of Radiology, Turku University Hospital and Turku University, Turku, Finland
| | - Jonathan Downer
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, United Kingdom
| | - Antti Lindgren
- Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland; Department of Neurosurgery, Kuopio University Hospital, Kuopio, Finland; Institute of Clinical Medicine, School of Medicine, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
| | - Riitta Rautio
- Department of Radiology, Turku University Hospital, Turku, Finland
| |
Collapse
|
29
|
Zaitoun MM, Malky IE, Winklhofer S, Valavanis A, Baltsavias G. Unassisted and multiple microcatheter coiling of distal basilar aneurysms: Outcomes and literature review. Interv Neuroradiol 2021; 28:169-176. [PMID: 34053314 DOI: 10.1177/15910199211021718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
PURPOSE The best treatment for distal basilar artery aneurysms is controversial. We aimed to review our single-centre experience with coil embolisation of aneurysms at this location and compare it with the surgical and endovascular literature. METHODS Forty-two aneurysms in a distal basilar location in 42 consecutive patients (15 ruptured and 27 unruptured) were treated endovascularly from 2010 to 2015. Unassisted single and multiple microcatheter coil embolisation alone was used in all cases. We studied our immediate and long-term anatomical results, operative complications, and outcome. RESULTS The immediate angiographic results showed complete occlusion in 34 (81%), a neck remnant in seven (16.6%) and a residual aneurysm in one patient (2.4%). There were two thromboembolic events (4.7%) without clinical sequelae; therefore, the operative morbidity and mortality were zero.Three patients with ruptured aneurysms (7.1%) died due to complicated vasospasm. Thirty-nine patients (93%) had clinical and MR imaging follow-up (mean 32.3 months ± 18.6, range from 12 to 66 months). There was recanalization in 30.8% with a retreatment rate of 15.3% and no new bleedings. The aneurysm size was the most important predictor of early anatomical outcome and recurrence. CONCLUSION Unassisted and multiple microcatheter coiling is a safe treatment for distal basilar aneurysms. Early anatomical results and recurrence depend on the aneurysm size. Morbidity and mortality are lower and recurrence rates are higher in comparison with clipping or other adjunctive endovascular techniques.
Collapse
Affiliation(s)
- Mohamed Ma Zaitoun
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland.,Diagnostic and Interventional Radiology Department, Faculty of Human Medicine, Zagazig University, Sharkia, Egypt
| | - Islam El Malky
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland.,Department of Neurology, Interventional Neurovascular Unit, Faculty of Medicine, South Valley University, Qena, Egypt
| | - Sebastian Winklhofer
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Anton Valavanis
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| | - Gerasimos Baltsavias
- Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
30
|
Lee KS, Zhang JJY, Nguyen V, Han J, Johnson JN, Kirollos R, Teo M. The evolution of intracranial aneurysm treatment techniques and future directions. Neurosurg Rev 2021; 45:1-25. [PMID: 33891216 PMCID: PMC8827391 DOI: 10.1007/s10143-021-01543-z] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 03/21/2021] [Accepted: 04/07/2021] [Indexed: 01/06/2023]
Abstract
Treatment techniques and management guidelines for intracranial aneurysms (IAs) have been continually developing and this rapid development has altered treatment decision-making for clinicians. IAs are treated in one of two ways: surgical treatments such as microsurgical clipping with or without bypass techniques, and endovascular methods such as coiling, balloon- or stent-assisted coiling, or intravascular flow diversion and intrasaccular flow disruption. In certain cases, a single approach may be inadequate in completely resolving the IA and successful treatment requires a combination of microsurgical and endovascular techniques, such as in complex aneurysms. The treatment option should be considered based on factors such as age; past medical history; comorbidities; patient preference; aneurysm characteristics such as location, morphology, and size; and finally the operator’s experience. The purpose of this review is to provide practicing neurosurgeons with a summary of the techniques available, and to aid decision-making by highlighting ideal or less ideal cases for a given technique. Next, we illustrate the evolution of techniques to overcome the shortfalls of preceding techniques. At the outset, we emphasize that this decision-making process is dynamic and will be directed by current best scientific evidence, and future technological advances.
Collapse
Affiliation(s)
- Keng Siang Lee
- Bristol Medical School, Faculty of Health Sciences, University of Bristol, Bristol, UK. .,Department of Neurosurgery, Bristol Institute of Clinical Neuroscience, Southmead Hospital, Bristol, UK.
| | - John J Y Zhang
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Vincent Nguyen
- Department of Neurosurgery, Bristol Institute of Clinical Neuroscience, Southmead Hospital, Bristol, UK.,Department of Neurosurgery, University of Tennessee Health Sciences Center, Memphis, TN, USA
| | - Julian Han
- Department of Neurosurgery, National Neuroscience Institute, Singapore, Singapore
| | - Jeremiah N Johnson
- Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA
| | - Ramez Kirollos
- Department of Neurosurgery, National Neuroscience Institute, Singapore, Singapore.,Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge and Addenbrooke's Hospital, Cambridge, UK
| | - Mario Teo
- Department of Neurosurgery, Bristol Institute of Clinical Neuroscience, Southmead Hospital, Bristol, UK
| |
Collapse
|
31
|
Rai AT, Brotman RG, Hobbs GR, Boo S. Semi-automated cerebral aneurysm segmentation and geometric analysis for WEB sizing utilizing a cloud-based computational platform. Interv Neuroradiol 2021; 27:828-836. [PMID: 33823619 DOI: 10.1177/15910199211009111] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Accurate aneurysm measurements are important for selecting the WEB device. The objective was to validate a cloud-based platform, SurgicalPreview (SP) against manual measurements for aneurysm analysis. METHODS Two sets of measurements each for SP and manual methods were obtained for 40 aneurysms. Reliability and agreement were assessed with intra-class correlation coefficient (ICC) and Bland-Altman plots respectively. Kappa coefficient was used to assess agreement for predicting WEB size. RESULTS There was good reliability for repeat SP measurements: aneurysm diameter (ICC-1, 95%CI 0.98-1), height (ICC-1, 95%CI 0.99-1) and neck diameter (ICC-0.96, 95%CI 0.93-0.98). There was good reliability for the two manual diameter (ICC-0.97, 95%CI 0.9-0.97) and height (ICC-0.93, 95%CI 0.87-0.96) measurements and moderate for neck diameter (ICC-0.76, 95%CI 0.54-0.87). There was greater agreement for SP versus manual repeat measurements on Bland-Altman plots. Reliability between the SP and manual methods was good for aneurysm diameter (ICC-0.98, 95%CI 0.95-1) and height (ICC-0.96, 95%CI-0.93-0.98) and moderate for neck. (ICC-0.6, 95%CI -0.22-0.87). The Bland-Altman plots confirmed better agreement between the two methods for the aneurysm diameter and height than the neck. There was strong agreement between the methods for predicting the WEB diameter (Kappa-0.84, 95%CI 0.71-0.97) and moderate for predicting WEB height (Kappa-0.66, 95%CI 0.43-0.89). There was moderate agreement for predicted versus deployed WEB diameter: SP (Kappa-0.56, 95%CI 0.38-0.74), Manual (Kappa-0.53, 95%CI 0.34-0.71). CONCLUSION The SurgicalPreview® had greater agreement for repeat measurements. There was good reliability between the two methods for predicting WEB diameter and height and moderate agreement between predicted versus deployed WEB diameter.
Collapse
Affiliation(s)
- Ansaar T Rai
- Interventional Neuroradiology, Rockefeller Neuroscience Institute, West Virginia University School of Medicine, Morgantown, WV, USA
| | - Ryan G Brotman
- Neuroradiology, West Virginia University School of Medicine, Morgantown, WV, USA
| | - Gerald R Hobbs
- Statistics, West Virginia University School of Medicine, Morgantown, WV, USA
| | - SoHyun Boo
- Interventional Neuroradiology, Rockefeller Neuroscience Institute, West Virginia University School of Medicine, Morgantown, WV, USA
| |
Collapse
|
32
|
Sahnoun M, Soize S, Manceau PF, Gelmini C, Pierot L. Intracranial aneurysm treatment with WEB and adjunctive stent: preliminary evaluation in a single-center series. J Neurointerv Surg 2021; 14:164-168. [PMID: 33785641 PMCID: PMC8785053 DOI: 10.1136/neurintsurg-2021-017379] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/12/2021] [Accepted: 03/15/2021] [Indexed: 12/04/2022]
Abstract
Background Intrasaccular flow disruption with WEB is a safe and efficacious technique that has significantly changed endovascular management of wide-neck bifurcation aneurysms (WNBAs). Use of stent in combination with WEB is occasionally required. We analyzed the frequency of use, indications, safety, and efficacy of the WEB–stent combination. Methods All aneurysms treated with WEB and stent were extracted from a prospectively maintained database. Patient and aneurysm characteristics, complications, and anatomical results were independently analyzed by a physician independent of the procedures. Results From June 2011 to January 2020, 152 patients with 157 aneurysms were treated with WEB. Of these, 17/152 patients (11.2%) with 19/157 aneurysms (12.1%) were treated with WEB device and stent. Indications were very wide neck with a branch emerging from the neck in 1/19 (5.2%) aneurysms and WEB protrusion in 18/19 (94.7%). At 1 month, no morbimortality was reported. At 6 months, anatomical results were complete aneurysm occlusion in 15/17 aneurysms (88.2%), neck remnant in 1/17 (5.9%), and aneurysm remnant in 1/17 (5.9%). At 12 months, there was complete aneurysm occlusion in 13/14 aneurysms (92.9%) and neck remnant in 1/14 (7.1%). Conclusions Combining WEB and stent is a therapeutic strategy to manage WNBA. In our series, this combination was used in 11.2% of patients treated with WEB, resulting in no morbidity or mortality with a high efficacy at 6 and 12 months (complete aneurysm occlusion in 88.2% and 92.9%, respectively).
Collapse
Affiliation(s)
- Maher Sahnoun
- Department of Neuroradiology, Hôpital Maison-Blanche, CHU Reims, Reims, France
| | - Sébastien Soize
- Department of Neuroradiology, Hôpital Maison-Blanche, CHU Reims, Reims, France
| | | | - Christophe Gelmini
- Department of Neuroradiology, Hôpital Maison-Blanche, CHU Reims, Reims, France
| | - Laurent Pierot
- Department of Neuroradiology, Hôpital Maison-Blanche, CHU Reims, Reims, France
| |
Collapse
|
33
|
Shrivastava A, Mishra R, Salazar LRM, Chouksey P, Raj S, Agrawal A. Enigma of what is Known about Intracranial Aneurysm Occlusion with Endovascular Devices. J Stroke Cerebrovasc Dis 2021; 30:105737. [PMID: 33774553 DOI: 10.1016/j.jstrokecerebrovasdis.2021.105737] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 02/23/2021] [Accepted: 02/28/2021] [Indexed: 11/16/2022] Open
Abstract
Aneurysmal subarachnoid Hemorrhage is a major cause of neurological morbidity and mortality. Over the years vascular neurosurgery has witnessed technological advances aimed to reduce the morbidity and mortality. Several endovascular devices have been used in clinical practice to achieve this goal in the management of ruptured and unruptured cerebral aneurysms. Recurrence due to recanalization is encountered in all of these endovascular devices as well as illustrated by Barrow Ruptured Aneurysm Trial. Histological and molecular characterization of the aneurysms treated with endovascular devices is an area of active animal and human research studies. Yet, the pathobiology illustrating the mechanisms of aneurysmal occlusion and healing lacks evidence. The enigma of aneurysmal healing following treatment with endovascular devices needs to be de-mystified to understand the biological interaction of endovascular device and aneurysm and thereby guide the future development of endovascular devices aimed at better aneurysm occlusion. We performed a comprehensive and detailed literature review to bring all the known facts of the pathobiology of intracranial aneurysm healing, the knowledge of which is of paramount importance to neurosurgeons, an interventional neuroradiologist, molecular biologist, geneticists, and experts in animal studies. This review serves as a benchmark of what is known and platform for future studies basic science research related to intracranial aneurysms.
Collapse
Affiliation(s)
- Adesh Shrivastava
- Department of Neurosurgery, All India Institute of Medical Sciences, Saket Nagar, Bhopal 462020, Madhya Pradesh, India.
| | - Rakesh Mishra
- Department of Neurosurgery, All India Institute of Medical Sciences, Bhopal, India
| | | | - Pradeep Chouksey
- Department of Neurosurgery, All India Institute of Medical Sciences, Saket Nagar, Bhopal 462020, Madhya Pradesh, India
| | - Sumit Raj
- Department of Neurosurgery, All India Institute of Medical Sciences, Saket Nagar, Bhopal 462020, Madhya Pradesh, India
| | - Amit Agrawal
- Department of Neurosurgery, All India Institute of Medical Sciences, Saket Nagar, Bhopal 462020, Madhya Pradesh, India
| |
Collapse
|
34
|
Won SY, Seifert V, Dubinski D, Kashefiolasl S, Dinc N, Bruder M, Konczalla J. Short- and midterm outcome of ruptured and unruptured intracerebral wide-necked aneurysms with microsurgical treatment. Sci Rep 2021; 11:4982. [PMID: 33654126 PMCID: PMC7925666 DOI: 10.1038/s41598-021-84339-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 02/15/2021] [Indexed: 11/23/2022] Open
Abstract
To clip or coil has been matter of debates for several years and is the domain of interdisciplinary decision making. However, the microsurgical outcome has still been elusive concerning wide neck aneurysms (WNA). A retrospective single center study was performed with all patients with ruptured WNA (rWNA) and unruptured WNA (uWNA) admitted to author´s institute between 2007–2017. Microsurgical outcome was evaluated according to Raymond-Roy occlusion grade and follow-up angiography was performed to analyze the stability of neck/aneurysm remnants and retreatment poverty. Of 805 aneurysms, 139 were rWNA (17.3%) and 148 uWNA (18.4%). Complete occlusion was achieved in 102 of 139 rWNA (73.4%) and 112 of 148 uWNA (75.6%). Neck remnants were observed in 36 patients with rWNA (25.9%) and 30 patients with uWNA (20.3%), 1 (0.7%) and 6 (4.1%) patients had aneurysmal remnant, respectively. Overall complication rate was 11.5%. At follow-up (939/1504 months), all remnants were stable except for one, which was further conservatively treated with marginal retreatment rate under 1%. Even the risk of de-novo aneurysm was higher than the risk for remnant growth (2.6% vs 0% in rWNA; 8.7% vs 5.3% in uWNA) without significant difference. Microsurgical clipping is effective for complete occlusion of r/uWNA with low complication. Furthermore, the risk of remnant growth is marginal even lower than the risk of de-novo rate low retreatment rate.
Collapse
Affiliation(s)
- Sae-Yeon Won
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany.
| | - Volker Seifert
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany
| | - Daniel Dubinski
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany
| | - Sepide Kashefiolasl
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany
| | - Nazife Dinc
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany
| | - Markus Bruder
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany
| | - Juergen Konczalla
- Department of Neurosurgery, University Hospital, Goethe-University, Frankfurt am Main, Germany
| |
Collapse
|
35
|
Zimmer S, Maus V, Maurer C, Berlis A, Weber W, Fischer S. Widening the Indications for Intrasaccular Flow Disruption: WEB 17 in the Treatment of Aneurysm Locations Different from Those in the Good Clinical Practice Trials. AJNR Am J Neuroradiol 2021; 42:524-529. [PMID: 33509918 DOI: 10.3174/ajnr.a6946] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 10/12/2020] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND PURPOSE The safety and efficacy of the Woven EndoBridge (WEB) device has been shown in multiple good clinical practice trials, whereas aneurysm locations in these trials were restricted to bifurcation aneurysms located at the circle of Willis (MCA bifurcation, ICA bifurcation, anterior communicating artery, basilar artery tip). Our aim was to evaluate angiographic and clinical results with the WEB 17 in aneurysm locations that were excluded from the good clinical practice trials, assuming that the angiographic and clinical results are similar to those of the good clinical practice trials for aneurysms in traditional locations. MATERIALS AND METHODS We performed retrospective analysis of immediate and follow-up results of aneurysms in locations outside the good clinical practice trials in which the WEB 17 was used on an intention-to-treat approach. RESULTS Between June 2017 and May 2020, forty-seven aneurysms in 44 patients met the inclusion criteria. Aneurysm locations were the ICA posterior communicating artery in 19 (40.3%), the ICA paraophthalmic or choroidal locations in 4 (8.6%), anterior cerebral artery A2 segment in 13 (27.7%), MCA M1 segment in 2 (4.3%), posterior cerebral artery P2 segment in 2 (4.3%), PICA in 3 (6.4%), and the superior cerebellar artery in 4 (8.4%) cases. The procedure-related morbidity and mortality rates in the entire series were 0.0%. The early and late (<12 and >12 months) complete occlusion rates were 63.9% (23/36) and 77.8% (14/18), respectively. CONCLUSIONS The WEB 17 is safe and effective in aneurysm locations different from the traditional bifurcation aneurysms included in the good clinical practice trials. Further studies will help to define the entire spectrum of aneurysm morphologies and locations suitable for the WEB 17.
Collapse
Affiliation(s)
- S Zimmer
- From the Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin (S.Z., V.M., W.W., S.F.), Universitätsklinik, Knappschaftskrankenhaus Bochum-Langendreer, Bochum, Germany
| | - V Maus
- From the Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin (S.Z., V.M., W.W., S.F.), Universitätsklinik, Knappschaftskrankenhaus Bochum-Langendreer, Bochum, Germany
| | - C Maurer
- Klinik für Diagnostische Radiologie und Neuroradiologie (C.M., A.B.), Klinikum Augsburg, Augsburg, Germany
| | - A Berlis
- Klinik für Diagnostische Radiologie und Neuroradiologie (C.M., A.B.), Klinikum Augsburg, Augsburg, Germany
| | - W Weber
- From the Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin (S.Z., V.M., W.W., S.F.), Universitätsklinik, Knappschaftskrankenhaus Bochum-Langendreer, Bochum, Germany
| | - S Fischer
- From the Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin (S.Z., V.M., W.W., S.F.), Universitätsklinik, Knappschaftskrankenhaus Bochum-Langendreer, Bochum, Germany
| |
Collapse
|
36
|
Kühn AL, Singh J, de Macedo Rodrigues K, Massari F, Moholkar VM, Marwah SK, Unar D, Gounis MJ, Puri AS. Distal radial artery (Snuffbox) access for intracranial aneurysm treatment using the Woven EndoBridge (WEB) device. J Clin Neurosci 2020; 81:310-315. [DOI: 10.1016/j.jocn.2020.10.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 09/14/2020] [Accepted: 10/03/2020] [Indexed: 01/25/2023]
|
37
|
Chen J, Li M, Zhu X, Chen Y, Zhang C, Shi W, Chen Q, Wang Y. Anterior Communicating Artery Aneurysms: Anatomical Considerations and Microsurgical Strategies. Front Neurol 2020; 11:1020. [PMID: 33013671 PMCID: PMC7509403 DOI: 10.3389/fneur.2020.01020] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 08/04/2020] [Indexed: 11/29/2022] Open
Abstract
Anterior communicating artery aneurysms account for 23–40% of ruptured intracranial aneurysms and 12–15% of unruptured aneurysms and are the most common intracranial ruptured or unruptured aneurysms. Because they have relatively complex anatomical structures and anatomical variations and are adjacent to important blood vessels and structures, in the process of microsurgical exposure of an Anterior communicating artery aneurysm, attention should be paid not only to the anatomical characteristics of the aneurysm itself but also to the adjacent important blood vessels and perforating arteries; therefore, both surgical clipping and endovascular embolization are serious challenges for neurosurgeons. No matter which treatment is chosen, it is necessary to determine the structure of the Anterior communicating artery and its perforating arteries as well as whether there is a fenestration deformity of the Anterior communicating artery and the relationship between bilateral A1-A2 before surgery. The shape and size of the aneurysm itself and its location relative to adjacent blood vessels also need to be considered to better complete the procedure, and this is especially true for microsurgical clipping. Clarifying the anatomy before surgery is helpful for better selecting the surgical approach and surgical side, which could affect the intraoperative exposure of the aneurysm and adjacent arteries, the surgical difficulty, the resection rate, and the postoperative complications. Therefore, starting with Anterior communicating artery aneurysms and their adjacent structures and variations, this paper reviews the latest progress in surgical treatment based on anatomic specificity as well as the most recent clinical studies.
Collapse
Affiliation(s)
- Junhui Chen
- Department of Neurosurgery, Renmin Hospital of Wuhan University, Wuhan, China.,Department of Neurosurgery, 904th Hospital of Joint Logistic Support Force of PLA, Wuxi Clinical College of Anhui Medical University, Wuxi, China
| | - Mingchang Li
- Department of Neurosurgery, 904th Hospital of Joint Logistic Support Force of PLA, Wuxi Clinical College of Anhui Medical University, Wuxi, China
| | - Xun Zhu
- Department of Neurosurgery, Renmin Hospital of Wuhan University, Wuhan, China
| | - Yan Chen
- Department of Internal Medicine, Hexian Hospital of Traditional Chinese Medicine, Ma'anshan, China
| | - Chunlei Zhang
- Department of Neurosurgery, Renmin Hospital of Wuhan University, Wuhan, China
| | - Wenwen Shi
- Department of Internal Medicine, Hexian Hospital of Traditional Chinese Medicine, Ma'anshan, China
| | - Qianxue Chen
- Department of Neurosurgery, 904th Hospital of Joint Logistic Support Force of PLA, Wuxi Clinical College of Anhui Medical University, Wuxi, China
| | - Yuhai Wang
- Department of Neurosurgery, Renmin Hospital of Wuhan University, Wuhan, China
| |
Collapse
|
38
|
Pierot L, Molyneux A, Byrne J, Spelle L. Retreatments are part of the evaluation of device performance … but have to be analyzed separately. J Neurointerv Surg 2020; 13:e6. [PMID: 32929048 DOI: 10.1136/neurintsurg-2020-016773] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 08/19/2020] [Indexed: 11/04/2022]
Affiliation(s)
- Laurent Pierot
- Neuroradiology, Hôpital Maison-Blanche, CHU Reims, Université Reims-Champagne-Ardenne, Reims, France
| | - Andy Molyneux
- Neurovascular and Neuroradiology Research Unit, Oxford University, Oxford, UK
| | - James Byrne
- Neuroradiology, Oxford University, Oxford, UK
| | - Laurent Spelle
- Interventional Neuroradiology, CHU Bicêtre, Le Kremlin-Bicetre, Île-de-France, France
| |
Collapse
|
39
|
Treatment of Ruptured and Unruptured Intracranial Aneurysms with WEB 17 Versus WEB 21 Systems : Comparison of Indications and Early Angiographic Outcomes. Clin Neuroradiol 2020; 31:691-697. [PMID: 32880656 DOI: 10.1007/s00062-020-00946-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/30/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND The concept of intrasaccular flow diversion using the Woven EndoBridge (WEB) device changed the traditional endovascular concept for wide-necked bifurcation aneurysms. The latest technical advancement resulted in the WEB 17 system, a softer device composed of fewer wires which enables treatment of smaller more distally located aneurysms by using smaller microcatheters as compared to the WEB 21 system. OBJECTIVE This retrospective observational study aimed to evaluate and compare the angiographic and clinical results achieved with WEB 21 and WEB 17 in aneurysm morphologies eligible for both systems (maximum width 3-6 mm). METHODS Between August 2014 and August 2019 a total of 63 and 130 aneurysms with a maximum width of 3-6 mm were treated with either WEB 21 and WEB 17, respectively, at 2 neurovascular centers. Cases were analyzed based on a comparison regarding aneurysm size, location and rupture status. RESULTS The technical success, the periprocedural complication rate and the rate of additional devices used showed no relevant differences between the two groups. Aneurysms treated with the WEB 17 system were smaller and more frequently distally located. The overall complete occlusion rate at 3 months was higher in the WEB 17 group (65.5% versus 55.1%). The superiority of complete aneurysm occlusion achieved with WEB 17 was statistically significant in the subgroup of unruptured middle cerebral artery aneurysms. CONCLUSION The use of WEB 17 expands the treatment indications for intrasaccular flow-diversion towards smaller and more distally located aneurysms with a safety profile comparable with that of the WEB 21.
Collapse
|
40
|
De Vries J, Boogaarts HD, Sørensen L, Holtmannspoetter M, Benndorf G, Turowski B, Bohner G, Derakhshani S, Navasa C, van Zwam WH, Söderman M, Rautio R, Mathys C, Riina H, Marotta TR. eCLIPs bifurcation remodeling system for treatment of wide neck bifurcation aneurysms with extremely low dome-to-neck and aspect ratios: a multicenter experience. J Neurointerv Surg 2020; 13:438-442. [PMID: 32788388 PMCID: PMC8053345 DOI: 10.1136/neurintsurg-2020-016354] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 07/01/2020] [Accepted: 07/07/2020] [Indexed: 12/03/2022]
Abstract
Background Wide necked bifurcation aneurysms (WNBA) are among the most difficult aneurysms to treat. Very low dome-to-neck (DTN) and aspect ratios provide an even greater challenge in the management of WNBAs. We present the safety and efficacy profile for endovascular clip system (eCLIPs) device in the treatment of this subset of WNBAs with very unfavorable morphologies. Methods In our case series, 24 patients treated at 12 international centers were taken from a larger prospective voluntary post-marketing registry of 65 patients treated with the eCLIPs device and coiling. Those who had WNBAs at either the carotid or basilar terminus with a DTN ratio <1.6 and aspect ratio <1.2 were included. Radiologic and clinical outcomes were assessed immediately after the procedure and at the latest follow-up. Results The eCLIPs device was successfully deployed in 23 cases (96%). One patient (4.2%) died due to guidewire perforation distal to the implant site. No other complications were documented. After a mean follow-up of 15.8 months (range 3–40 months), good radiologic outcomes (modified Raymond–Roy classification (MRRC) scores of 1 or 2) were documented in 20 of 21 patients (95%) with follow-up data. The lone patient with an MRRC score of 3 showed coiled compaction after incomplete neck coverage with the device. Conclusion Our series of patients with aneurysms having adverse DTN and aspect ratios demonstrated that the eCLIPs device has a safety and efficacy profile comparable with currently available devices in the treatment of WNBAs.
Collapse
Affiliation(s)
- Joost De Vries
- Neurosurgery Department, Radboud University Medical Center, Nijmegen, The Netherlands
| | | | - Leif Sørensen
- Neuroradiology, Aarhus University Hospital, Aarhus, Denmark
| | | | - Goetz Benndorf
- INR, Rigshospital Copenhagen, Copenhagen, Denmark.,Radiology, Baylor College of Medicine, Houston, Texas, USA
| | - Bernd Turowski
- Radiology, University of Duesseldorf, Düsseldorf, Germany
| | - Georg Bohner
- Neuroradiology, Charite Universitatsmedizin Berlin, Berlin, Germany
| | - Shahram Derakhshani
- Neuroradiology, Essex Center for Neurological Sciences, Queen's University Hospital, Romdord, UK
| | - Chema Navasa
- Neuroradiology, Hospital Universitario Miguel Servet, Zaragoza, Spain
| | - Wim H van Zwam
- Radiology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Michael Söderman
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | | | - Christian Mathys
- Institute of Radiology and Neuroradiology, Evangelisches Krankenhaus, University of Oldenburg, Oldenburg, Germany
| | | | - Thomas R Marotta
- Diagnostic and Therapeutic Neuroradiology, St Michael's Hospital, Toronto, Ontario, Canada
| |
Collapse
|
41
|
Nguyen HA, Soize S, Manceau PF, Vudang L, Pierot L. Persistent Blood Flow inside the Woven EndoBridge Device More Than 6 Months after Intracranial Aneurysm Treatment: Frequency, Mechanisms, and Management-A Retrospective Single-Center Study. AJNR Am J Neuroradiol 2020; 41:1225-1231. [PMID: 32527839 DOI: 10.3174/ajnr.a6593] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Accepted: 04/14/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Due to its high safety and great efficacy, flow disruption with the Woven EndoBridge (WEB) device is increasingly used to treat intracranial aneurysms. We recently identified patients with intracranial aneurysm treated with the WEB who presented with residual blood flow inside the device ("contrast-in-WEB" phenomenon) more than 6 months posttreatment. This series reports the frequency and underlying mechanisms and discusses management of this phenomenon. MATERIALS AND METHODS All patients presenting with the contrast-in-WEB phenomenon in the prospectively collected data base of patients with aneurysm treated with the WEB were retrospectively collected and analyzed. RESULTS From June 2011 to February 2019, one hundred twenty-seven patients with 133 aneurysms were treated with the WEB and had DSA follow-up at 6 months or later. Eight patients (6.3%) presented with the phenomenon. All aneurysms were wide-neck bifurcation aneurysms, including 7 unruptured and 1 ruptured aneurysm located at the MCA (5 aneurysms), anterior communicating artery (2 aneurysms), and basilar artery (1 aneurysm). All except 1 patient received dual-antiplatelet therapy preprocedure. All except 1 patient received dual-antiplatelet therapy postoperatively for at least 1 month. The most likely mechanism of the phenomenon is the absence of intradevice thrombosis related to perioperative dual-antiplatelet medication. The phenomenon is also likely associated with a low risk of bleeding except when there is residual blood flow against the aneurysm wall or in the dome. CONCLUSIONS Contrast-in-WEB is a relatively rare phenomenon possibly induced by dual-antiplatelet therapy continued post-WEB procedure. In most cases, no additional treatment is required.
Collapse
Affiliation(s)
- H A Nguyen
- From the Department of Radiology (H.A.N., L.V.), Bach Mai Hospital, Hanoi, Vietnam
- Department of Neuroradiology (H.A.N., S.S., P.-F.M., L.P.), Hôpital Maison-Blanche, Reims, France
| | - S Soize
- Department of Neuroradiology (H.A.N., S.S., P.-F.M., L.P.), Hôpital Maison-Blanche, Reims, France
| | - P-F Manceau
- Department of Neuroradiology (H.A.N., S.S., P.-F.M., L.P.), Hôpital Maison-Blanche, Reims, France
| | - L Vudang
- From the Department of Radiology (H.A.N., L.V.), Bach Mai Hospital, Hanoi, Vietnam
| | - L Pierot
- Department of Neuroradiology (H.A.N., S.S., P.-F.M., L.P.), Hôpital Maison-Blanche, Reims, France.
| |
Collapse
|
42
|
Maurer C, König I, Berlis A, Weber W, Fischer S. Two-Center Experience in the Endovascular Treatment of Intracranial Aneurysms Using the Woven EndoBridge 17 Device Including Midterm Follow-Up Results: A Retrospective Analysis. AJNR Am J Neuroradiol 2020; 40:1517-1522. [PMID: 31467237 DOI: 10.3174/ajnr.a6177] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2019] [Accepted: 07/05/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE The Woven EndoBridge device proved its effectiveness in the treatment of ruptured and unruptured intracranial aneurysms as a stand-alone device. Before 2016, Woven EndoBridge deployment required at least a 0.021-inch microcatheter. In 2016, a smaller device, the Woven EndoBridge 17 with finer size increments that used a 0.017-inch microcatheter, was introduced. We retrospectively analyzed our initial and follow-up results with the Woven EndoBridge 17 in ruptured and unruptured aneurysms. MATERIALS AND METHODS One hundred twenty-seven intracranial aneurysms in 117 patients were scheduled for treatment with the Woven EndoBridge 17 between June 2017 and February 2019. Twenty-nine aneurysms were ruptured. RESULTS Treatment was performed as intended in 124 of 127 cases (97.6%). Additional devices such as stents or coils were used in 12 cases (9.7%). Five thromboembolic complications and 1 hemorrhagic complication were encountered, resulting in clinical deterioration in 2 patients. The overall morbidity and mortality in the entire series have been 1.7% and 0.0% to date, respectively. The follow-up results at 3 and 12 months revealed complete occlusion in 76.1% (70/92) and 78.0% (32/41). CONCLUSIONS The Woven EndoBridge 17 device is safe in the treatment of small broad-based aneurysms without the general need for additional devices. The low complication rate and the promising follow-up results underline the value of this technique in a growing range of endovascular treatment options for intracranial aneurysms.
Collapse
Affiliation(s)
- C Maurer
- Klinikum Augsburg (C.M., A.B.), Klinik für Diagnostische Radiologie und Neuroradiologie, Ausburg, Germany
| | - I König
- From the Knappschaftskrankenhaus Bochum-Langendreer (I.K., W.W., S.F.), Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin, Bochum, Germany
| | - A Berlis
- Klinikum Augsburg (C.M., A.B.), Klinik für Diagnostische Radiologie und Neuroradiologie, Ausburg, Germany
| | - W Weber
- From the Knappschaftskrankenhaus Bochum-Langendreer (I.K., W.W., S.F.), Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin, Bochum, Germany
| | - S Fischer
- From the Knappschaftskrankenhaus Bochum-Langendreer (I.K., W.W., S.F.), Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie, Nuklearmedizin, Bochum, Germany
| |
Collapse
|
43
|
Peterson J, Goyal N, Arthur AS, Fiorella D. Technical aspects of web device in aneurysm treatment. J Neurointerv Surg 2020; 12:924. [PMID: 32475818 PMCID: PMC7476365 DOI: 10.1136/neurintsurg-2019-015748] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 04/17/2020] [Accepted: 04/21/2020] [Indexed: 11/06/2022]
Abstract
Wide-neck bifurcation aneurysms (WNBAs) make up 26–36% of all brain aneurysms. Intrasaccular flow disruption is an innovative technique for the treatment of WNBAs. The Woven EndoBridge (WEB) device (Sequent Medical, Aliso Viejo, California USA) is the only United States Food and Drug Administration approved intrasaccular flow disruption device. In this video article, a few cases of intracranial aneurysms treated with the WEB device are presented and various aspects of treating WNBAs with the WEB device, including aneurysm/device selection strategies, and procedural technique, are discussed (video 1).
Collapse
Affiliation(s)
- Jeremy Peterson
- Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA.,Department of Neurosurgery, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - Nitin Goyal
- Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA.,Department of Neurology, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - Adam S Arthur
- Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee, USA .,Department of Neurosurgery, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - David Fiorella
- Stony Brook University Hospital, Stony Brook, New York, USA
| |
Collapse
|
44
|
Di Caterino F, Primikiris P, Vitale G, Biondi A. Woven EndoBridge Device immediate post-detachment tilt with later displacement: Case report, rescue techniques, and review of the literature. Interv Neuroradiol 2020; 26:483-487. [PMID: 32436457 DOI: 10.1177/1591019920926334] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The Woven EndoBridge Device (WEB) is efficient and safe in the treatment of wide-neck bifurcation intracranial aneurysms. A crucial step in operative planning is establishing the appropriate dimension of the device, and there are limitations to the therapeutic solutions provided by WEBs. We describe a case of a right middle cerebral artery bifurcation wide-neck aneurysm treated with WEB. After the initial deployment of a WEB proven oversized, we substituted it with a smaller one that presented immediate post-detachment intra-aneurysmal tilt probably resulting from undersizing. The 24-h angiographic control identified a partial displacement of the device in the superior middle cerebral artery branch. We describe rescue techniques with review of the literature and our treatment strategy, including effort to reposition the device followed by stent deployment. The treatment was electively completed by the coil-through technique. The post-detachment WEB tilt should be considered an unstable position and treated either by removal of the device or with adjunctive implants. Each WEB size adapts to a range of aneurysmal height and width. This range is not always the same for each specific WEB dimension, based on the table provided by the manufacturer. This eventually predisposes to a different behavior of different WEB sizes regarding the modification of the device's height in relation to the modification of the diameter after deployment.
Collapse
Affiliation(s)
- Fortunato Di Caterino
- Department of Interventional Neuroradiology, Jean-Minjoz University Hospital, Besançon, France
| | - Panagiotis Primikiris
- Department of Interventional Neuroradiology, Jean-Minjoz University Hospital, Besançon, France
| | - Giovanni Vitale
- Department of Interventional Neuroradiology, Jean-Minjoz University Hospital, Besançon, France
| | - Alessandra Biondi
- Department of Interventional Neuroradiology, Jean-Minjoz University Hospital, Besançon, France
| |
Collapse
|
45
|
Goyal N, Hoit D, DiNitto J, Elijovich L, Fiorella D, Pierot L, Lamin S, Spelle L, Saatci I, Cekirge S, Arthur AS. How to WEB: a practical review of methodology for the use of the Woven EndoBridge. J Neurointerv Surg 2020; 12:512-520. [PMID: 32005760 PMCID: PMC7231463 DOI: 10.1136/neurintsurg-2019-015506] [Citation(s) in RCA: 110] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 12/10/2019] [Accepted: 12/24/2019] [Indexed: 11/29/2022]
Abstract
Wide-necked bifurcation aneurysms (WNBAs) make up 26-36% of all brain aneurysms. Treatments for WNBAs pose unique challenges due to the need to preserve major bifurcation vessels while achieving a durable occlusion of the aneurysm. Intrasaccular flow disruption is an innovative technique for the treatment of WNBAs. The Woven EndoBridge (WEB) device is the only United States Food and Drug Administration approved intrasaccular flow disruption device. In this review article we discuss various aspects of treating WNBAs with the WEB device, including indications for use, aneurysm/device selection strategies, antiplatelet therapy requirement, procedural technique, potential complications and bailouts, and management strategies for residual/recurrent aneurysms after initial WEB treatment.
Collapse
Affiliation(s)
- Nitin Goyal
- Neurology, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - Daniel Hoit
- Neurosurgery, University of Tennessee Health Science Center, Memphis, Tennessee, USA
- Department of Neurosurgery, Semmes-Murphey Clinic, Memphis, Tennessee, USA
| | - Julie DiNitto
- Department of Research Collaborations, Siemens Medical Solutions USA Inc, Hoffman Estates, Illinois, USA
| | - Lucas Elijovich
- Neurology, University of Tennessee Health Science Center, Memphis, Tennessee, USA
- Department of Neurosurgery, Semmes-Murphey Clinic, Memphis, Tennessee, USA
| | - David Fiorella
- Department of Neuroradiology, Stony Brook University Hospital, Stony Brook, New York, USA
| | - Laurent Pierot
- Neuroradiology, Reims Champagne-Ardenne University, Reims, France
| | - Saleh Lamin
- Department of Neuroradiology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Laurent Spelle
- Neuroradiology, NEURI Center, Bicetre Hospital, APHP, Paris-Saclay University, Saint-Aubin, France
| | - Isil Saatci
- Radiology, Koru Hospital, Yuksek Ihtisas Universitesi, Ankara, Turkey
| | - Saru Cekirge
- Radiology, Bayindir Hastanesi Kavaklidere, Ankara, Turkey
| | - Adam S Arthur
- Neurosurgery, University of Tennessee Health Science Center, Memphis, Tennessee, USA
- Department of Neurosurgery, Semmes-Murphey Clinic, Memphis, Tennessee, USA
| |
Collapse
|
46
|
Mihalea C, Caroff J, Ikka L, Benachour N, Da Ros V, Abdelkhalek H, Iacobucci M, Marenco de la Torre JJ, Pagiola I, Yasuda T, Popa BV, Ples H, Pescariu S, Moret J, Spelle L. Y-stenting with braided stents for wide-neck intracranial bifurcation aneurysms. A single-center initial experience. J Neuroradiol 2020; 47:227-232. [DOI: 10.1016/j.neurad.2018.12.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 12/27/2018] [Indexed: 10/27/2022]
|
47
|
Bhogal P, Lylyk I, Chudyk J, Perez N, Bleise C, Lylyk P. The Contour-Early Human Experience of a Novel Aneurysm Occlusion Device. Clin Neuroradiol 2020; 31:147-154. [PMID: 31993679 DOI: 10.1007/s00062-020-00876-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2018] [Accepted: 01/09/2020] [Indexed: 10/25/2022]
Abstract
BACKGROUND AND PURPOSE Endosaccular flow disruption is a recognized treatment options for treating both unruptured and ruptured aneurysms. The Contour device is designed to target the neck of an aneurysm and cause flow disruption within the aneurysm hence promoting thrombosis and neo-endothelialization at the neck. This article presents initial experiences with the Contour. METHODS The prospectively maintained database was retrospectively reviewed to identify patients treated with the Contour device. Demographic data, aneurysm characteristics, clinical result, and clinical and radiological follow-up information were recorded. RESULTS The review identified 3 patients (2 female), with 3 unruptured aneurysms, of average age 67 ± 8.7 years (range 62-77 years). The aneurysms were all located in the anterior circulation including one pericallosal, one at the A1-2 junction and one on the ICA bifurcation. The mean average dome height was 7.6 ± 0.62 mm (range 7.1-8.3 mm), dome width 5.7 ± 2 mm (range 3.5-7.5 mm), and neck width 3.6 ± 0.95 mm (range 2.5-4.2 mm). At follow-up angiography two of the aneurysms were completely occluded and one device had displaced into the aneurysm sac due to inappropriate positioning of the device. Of the patients one had minor stroke during the postoperative period but returned to baseline neurology. All patients were mRS 0 at last follow-up. CONCLUSION The Contour is a promising new aneurysm occlusion device. Further studies with longer term follow-up are required to determine the efficacy of this novel device.
Collapse
Affiliation(s)
- P Bhogal
- Department of Interventional Neuroradiology, The Royal London Hospital, Whitechapel Road, E1 1BB, London, UK.
| | - I Lylyk
- Neuroradiological clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - J Chudyk
- Neuroradiological clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - N Perez
- Neuroradiological clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - C Bleise
- Neuroradiological clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - P Lylyk
- Neuroradiological clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| |
Collapse
|
48
|
Akhunbay-Fudge CY, Deniz K, Tyagi AK, Patankar T. Endovascular treatment of wide-necked intracranial aneurysms using the novel Contour Neurovascular System: a single-center safety and feasibility study. J Neurointerv Surg 2020; 12:987-992. [PMID: 31974281 PMCID: PMC7509519 DOI: 10.1136/neurintsurg-2019-015628] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 12/23/2019] [Accepted: 01/04/2020] [Indexed: 11/05/2022]
Abstract
Background and purpose Wide-necked bifurcation aneurysms pose a significant challenge to the treating clinician. The Contour Neurovascular System embolization device is a novel tool for the treatment of such intracranial aneurysms. We report on our experience with this device. Methods Prospective clinical and radiological data were collected for all patients treated with the Contour device at our center. All our patients were treated on an elective basis. Results We have treated 11 patients successfully with the Contour device to date. All patients were women with a mean (SD) age of 65.0 (6.4) years. In total, four basilar tip, two internal carotid artery, three middle cerebral artery, one anterior communicating artery, and one superior cerebellar artery aneurysms were treated. At 1-year follow-up, complete occlusion (Raymond Class 1) was seen in 55.56% (5/9) of cases, with 44.44% (4/9) having small neck remnants (Raymond Class 2). One patient declined 1-year catheter angiography and another had no further follow-up due to an unrelated medical condition. For six patients, 2-year radiological follow-up is available and shows stability. At 6 weeks, nine of the 11 patients had a modifed Rankin Scale score of 0, with two patients scoring 1 for headaches. Two patients had thromboembolic events, but there were no complications leading to permanent neurological disability or death. We additionally had three patients where the Contour device was attempted but was unable to be successfully used. Conclusion Initial results are promising although larger case numbers and longer follow-up are necessary to draw further conclusions on the utility and risk profile of this new device.
Collapse
Affiliation(s)
- Christopher Yusuf Akhunbay-Fudge
- Neurosurgery, Leeds Teaching Hospitals NHS Trust, Leeds, UK.,Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Kenan Deniz
- Neurosurgery, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | | | - Tufail Patankar
- Interventional Neuroradiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| |
Collapse
|
49
|
Early clinical course after aneurysmal subarachnoid hemorrhage: comparison of patients treated with Woven EndoBridge, microsurgical clipping, or endovascular coiling. Acta Neurochir (Wien) 2019; 161:1763-1773. [PMID: 31280480 DOI: 10.1007/s00701-019-03992-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Accepted: 06/25/2019] [Indexed: 10/26/2022]
Abstract
BACKGROUND The Woven EndoBridge (WEB) device has been increasingly used for the treatment of intracranial aneurysms after aneurysmal subarachnoid hemorrhage (SAH). Still, recent major clinical trials on patient management after SAH have defined WEB embolization as an exclusion criterion. In an analysis of an unselected patient cohort, we evaluate the early clinical course of SAH patients after WEB treatment compared to those treated with endovascular coiling or surgical clipping. METHODS Data of all patients with proven SAH who were either treated with a WEB device, coil embolization, or neurosurgical clipping between March 2015 and August 2018 was systematically reviewed. Clinical parameters on intensive care unit (ICU), medical history and mortality rates were evaluated and compared between the different treatment approaches. RESULTS Of all 201 patients included, 107 patients received endovascular coil embolization, 56 patients were treated with clipping and in 38 cases a WEB device was placed. The overall mortality was 17.9%. Thirteen patients (34.2%) in the WEB group had a Hunt and Hess grade > 3. Essential medical factors showed no clinically relevant differences between the treatment groups, and the analyzed blood parameters were predominantly within physiological limits without any relevant outliers. The Hunt and Hess grade but not the treatment modality was identified as independent risk-factor associated with ICU-mortality in the overall cohort (p < 0.001). CONCLUSION In this study, there was no difference in the early clinical course between those treated with WEB embolization, coil embolization, or neurosurgical clipping. Since WEB embolization is a valuable treatment alternative to coiling, it seems not justified to exclude this procedure from upcoming clinical SAH trials, yet the clinical long-term outcome, aneurysm occlusion, and retreatment rates have to be analyzed in further studies. CLINICAL TRIAL REGISTRATION NUMBER not applicable.
Collapse
|
50
|
Muskens IS, Broekman MLD, Lycklama À Nijeholt GJ, Moojen WA. Letter: Laser Ablation of Abnormal Neurological Tissue using Robotic Neuroblate System (LAANTERN): Procedural Safety and Hospitalization. Neurosurgery 2019; 85:E619-E620. [PMID: 31418033 DOI: 10.1093/neuros/nyz278] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Affiliation(s)
- Ivo S Muskens
- Center for Genetic Epidemiology Department of Preventive Medicine Keck School of Medicine Los Angeles, California
| | - Marike L D Broekman
- Department of Neurosurgery Haaglanden Medical Center The Hague Zuid-Holland, The Netherlands
- Department of Neurosurgery Leiden University Medical Center Leiden Zuid-Holland, The Netherlands
- Department of Neurology Massachusetts General Hospital Harvard Medical School Boston, Massachusetts
| | | | - Wouter A Moojen
- Department of Neurosurgery Haaglanden Medical Center The Hague Zuid-Holland, The Netherlands
- Department of Neurosurgery Leiden University Medical Center Leiden Zuid-Holland, The Netherlands
- Department of Neurosurgery Haga Teaching Hospital The Hague Zuid-Holland, The Netherlands
| |
Collapse
|