1
|
Wang S, Sun W, Han D, Clark KP, Griffith BP, Wu ZJ. In vitro study on device-induced damage to blood cellular components and degradation of von Willebrand factor in a CentriMag pump-assisted circulation. Artif Organs 2024. [PMID: 38712632 DOI: 10.1111/aor.14766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 04/01/2024] [Accepted: 04/16/2024] [Indexed: 05/08/2024]
Abstract
BACKGROUND High mechanical shear stress (HMSS) generated by blood pumps during mechanical circulatory support induces blood damage (or function alteration) not only of blood cell components but also of plasma proteins. METHODS In the present study, fresh, healthy human blood was used to prime a blood circuit assisted by a CentriMag centrifugal pump at a flow rate of 4.5 L/min under three pump pressure heads (75, 150, and 350 mm Hg) for 4 h. Blood samples were collected for analyses of plasma-free hemoglobin (PFH), von Willebrand factor (VWF) degradation and platelet glycoprotein (GP) IIb/IIIa receptor shedding. RESULTS The extent of all investigated aspects of blood damage increased with increasing cross-pump pressure and duration. Loss of high-molecular-weight multimers (HMWM)-VWF in Loop 2 and Loop 3 significantly increased after 2 h. PFH, loss of HMWM-VWF, and platelet GPIIb/IIIa receptor shedding showed a good linear correlation with mean shear stress corresponding to the three pump pressure heads. CONCLUSIONS HMSS could damage red blood cells, cause pathological VWF degradation, and induce platelet activation and platelet receptor shedding. Different blood components can be damaged to different degrees by HMSS; VWF and VWF-enhanced platelet activation may be more susceptible to HMSS.
Collapse
Affiliation(s)
- Shigang Wang
- Artificial Organ Lab, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Wenji Sun
- Artificial Organ Lab, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Dong Han
- Artificial Organ Lab, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Kiersten P Clark
- Artificial Organ Lab, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Bartley P Griffith
- Artificial Organ Lab, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Zhongjun J Wu
- Artificial Organ Lab, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA
- Fischell Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, Maryland, USA
| |
Collapse
|
2
|
Knüppel F, Sun A, Wurm FH, Hussong J, Torner B. Effect of Particle Migration on the Stress Field in Microfluidic Flows of Blood Analog Fluids at High Reynolds Numbers. MICROMACHINES 2023; 14:1494. [PMID: 37630030 PMCID: PMC10456677 DOI: 10.3390/mi14081494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 07/19/2023] [Accepted: 07/21/2023] [Indexed: 08/27/2023]
Abstract
In the present paper, we investigate how the reductions in shear stresses and pressure losses in microfluidic gaps are directly linked to the local characteristics of cell-free layers (CFLs) at channel Reynolds numbers relevant to ventricular assist device (VAD) applications. For this, detailed studies of local particle distributions of a particulate blood analog fluid are combined with wall shear stress and pressure loss measurements in two complementary set-ups with identical flow geometry, bulk Reynolds numbers and particle Reynolds numbers. For all investigated particle volume fractions of up to 5%, reductions in the stress and pressure loss were measured in comparison to a flow of an equivalent homogeneous fluid (without particles). We could explain this due to the formation of a CFL ranging from 10 to 20 μm. Variations in the channel Reynolds number between Re = 50 and 150 did not lead to measurable changes in CFL heights or stress reductions for all investigated particle volume fractions. These measurements were used to describe the complete chain of how CFL formation leads to a stress reduction, which reduces the apparent viscosity of the suspension and results in the Fåhræus-Lindqvist effect. This chain of causes was investigated for the first time for flows with high Reynolds numbers (Re∼100), representing a flow regime which can be found in the narrow gaps of a VAD.
Collapse
Affiliation(s)
- Finn Knüppel
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| | - Ang Sun
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Frank-Hendrik Wurm
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| | - Jeanette Hussong
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Benjamin Torner
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| |
Collapse
|
3
|
Chan CHH, Murashige T, Bieritz SA, Semenzin C, Smith A, Leslie L, Simmonds MJ, Tansley GD. Mitigation effect of cell exclusion on blood damage in spiral groove bearings. J Biomech 2023; 146:111394. [PMID: 36462474 DOI: 10.1016/j.jbiomech.2022.111394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 11/10/2022] [Accepted: 11/16/2022] [Indexed: 11/27/2022]
Abstract
Cell exclusion in spiral groove bearing (SGB) excludes red blood cells from high shear regions in the bearing gaps and potentially reduce haemolysis in rotary blood pumps. However, this mechanobiological phenomenon has been observed in ultra-low blood haematocrit only, whether it can mitigate blood damage in a clinically-relevant blood haematocrit remains unknown. This study examined whether cell exclusion in a SGB alters haemolysis and/or high-molecular-weight von Willebrand factor (HMW vWF) multimer degradation. Citrated human blood was adjusted to 35 % haematocrit and exposed to a SGB (n = 6) and grooveless disc (n = 3, as a non-cell exclusion control) incorporated into a custom-built Couette test rig operating at 2000RPM for an hour; shearing gaps were 20, 30, and 40 μm. Haemolysis was assessed via spectrophotometry and HMW vWF multimer degradation was detected with gel electrophoresis and immunoblotting. Haemolysis caused by the SGB at gaps of 20, 30 and 40 μm were 10.6 ± 3.3, 9.6 ± 2.7 and 10.5 ± 3.9 mg/dL.hr compared to 23.3 ± 2.6, 12.8 ± 3.2, 9.8 ± 1.8 mg/dL.hr by grooveless disc. At the same shearing gap of 20 µm, there was a significant reduced in haemolysis (P = 0.0001) and better preserved in HMW vWF multimers (p < 0.05) when compared SGB to grooveless disc. The reduction in blood damage in the SGB compared to grooveless disc is indicative of cell exclusion occurred at the gap of 20 µm. This is the first experimental study to demonstrate that cell exclusion in a SGB mitigates the shear-induced blood damage in a clinically-relevant blood haematocrit of 35 %, which can be potentially utilised in future blood pump design.
Collapse
Affiliation(s)
- Chris Hoi Houng Chan
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia.
| | - Tomotaka Murashige
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; School of Engineering, Tokyo Institute of Technology, Meguro, Japan
| | - Shelby A Bieritz
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Department of Bioengineering, Rice University, Houston, TX, USA
| | - Clayton Semenzin
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
| | - Amanda Smith
- Menzies Health Institute Queensland, Griffith University, Queensland, Australia
| | - Laura Leslie
- Mechanical, Biomedical and Design Group, Aston University, Birmingham, UK
| | - Michael J Simmonds
- Menzies Health Institute Queensland, Griffith University, Queensland, Australia
| | - Geoff D Tansley
- School of Engineering and Built Environment, Griffith University, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Brisbane, Australia
| |
Collapse
|
4
|
Onder A, Yapici R, Incebay O. An experimental performance comparison of Newtonian and non-Newtonian fluids on a centrifugal blood pump. Proc Inst Mech Eng H 2022; 236:399-405. [PMID: 35014554 DOI: 10.1177/09544119211057626] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The use of substitute fluid with similar rheological properties instead of blood is important due to ethical concerns and high blood volume consumption in pump performance test before clinical applications. The performance of a centrifugal blood pump with hydrodynamic journal bearing is experimentally tested using Newtonian 40% aqueous glycerin solution (GS) and non-Newtonian aqueous xanthan gum solution of 600 ppm (XGS) as working fluids. Experiments are performed at four different rotational speeds which are 2700, 3000, 3300, and 3600 rpm; experiments using GS reach between 8.5% and 37.2% higher head curve than experiments using the XGS for every rotational speed. It was observed that as the rotational speed and flow rate increase, the head curve difference between GS and XGS decreases. This result can be attributed to the friction reduction effect when using XGS in experiments at high rotation speed and high flow rate. Moreover, due to different fluid viscosities, differences in hydraulic efficiency were observed for both fluids. This study reveals that the use of Newtonian fluids as working fluids is not sufficient to determine the actual performance of a blood pump, and the performance effects of non-Newtonian fluids are remarkably important in pump performance optimizations.
Collapse
Affiliation(s)
- Ahmet Onder
- Mechanical and Metal Technologies Department, Technical Sciences Vocational School, Konya Technical University, Konya, Turkey
| | - Rafet Yapici
- Mechanical Engineering Department, Faculty of Engineering and Natural Science, Konya Technical University, Konya, Turkey
| | - Omer Incebay
- Mechanical Engineering Department, Faculty of Engineering and Natural Science, Konya Technical University, Konya, Turkey
| |
Collapse
|
5
|
Ghadimi B, Nejat A, Nourbakhsh SA, Naderi N. Multi‐Objective Genetic Algorithm Assisted by an Artificial Neural Network Metamodel for Shape Optimization of a Centrifugal Blood Pump. Artif Organs 2018; 43:E76-E93. [DOI: 10.1111/aor.13366] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 09/14/2018] [Accepted: 09/24/2018] [Indexed: 12/17/2022]
Affiliation(s)
- Behnam Ghadimi
- School of Mechanical Engineering, College of Engineering University of Tehran Tehran Iran
| | - Amir Nejat
- School of Mechanical Engineering, College of Engineering University of Tehran Tehran Iran
| | - Seyed Ahmad Nourbakhsh
- School of Mechanical Engineering, College of Engineering University of Tehran Tehran Iran
| | - Nasim Naderi
- Rajaie Cardiovascular Medical and Research Center Tehran Iran
| |
Collapse
|
6
|
Thamsen B, Plamondon M, Granegger M, Schmid Daners M, Kaufmann R, Neels A, Meboldt M. Investigation of the Axial Gap Clearance in a Hydrodynamic-Passive Magnetically Levitated Rotary Blood Pump Using X-Ray Radiography. Artif Organs 2018; 42:510-515. [DOI: 10.1111/aor.13074] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 10/04/2017] [Accepted: 10/05/2017] [Indexed: 11/27/2022]
Affiliation(s)
- Bente Thamsen
- pd
- z Product Development Group Zurich, Department of Mechanical and Process Engineering; ETH Zurich; Zurich Switzerland
| | - Mathieu Plamondon
- Empa, Swiss Federal Laboratories for Material Science and Technology, Center for X-ray Analytics; Dübendorf Switzerland
| | - Marcus Granegger
- Pediatric Heart Center; University Children's Hospital, University of Zurich; Zurich Switzerland
| | - Marianne Schmid Daners
- pd
- z Product Development Group Zurich, Department of Mechanical and Process Engineering; ETH Zurich; Zurich Switzerland
| | - Rolf Kaufmann
- Empa, Swiss Federal Laboratories for Material Science and Technology, Center for X-ray Analytics; Dübendorf Switzerland
| | - Antonia Neels
- Empa, Swiss Federal Laboratories for Material Science and Technology, Center for X-ray Analytics; Dübendorf Switzerland
| | - Mirko Meboldt
- pd
- z Product Development Group Zurich, Department of Mechanical and Process Engineering; ETH Zurich; Zurich Switzerland
| |
Collapse
|
7
|
Wiegmann L, Boës S, de Zélicourt D, Thamsen B, Schmid Daners M, Meboldt M, Kurtcuoglu V. Blood Pump Design Variations and Their Influence on Hydraulic Performance and Indicators of Hemocompatibility. Ann Biomed Eng 2017; 46:417-428. [DOI: 10.1007/s10439-017-1951-0] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 10/25/2017] [Indexed: 12/11/2022]
|
8
|
|
9
|
O'Connor J, Day P, Mandal P, Revell A. Computational fluid dynamics in the microcirculation and microfluidics: what role can the lattice Boltzmann method play? Integr Biol (Camb) 2016; 8:589-602. [PMID: 27068565 DOI: 10.1039/c6ib00009f] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Patient-specific simulations, efficient parametric analyses, and the study of complex processes that are otherwise experimentally intractable are facilitated through the use of Computational Fluid Dynamics (CFD) to study biological flows. This review discusses various CFD methodologies that have been applied across different biological scales, from cell to organ level. Through this discussion the lattice Boltzmann method (LBM) is highlighted as an emerging technique capable of efficiently simulating fluid problems across the midrange of scales; providing a practical analytical tool compared to methods more attuned to the extremities of scale. Furthermore, the merits of the LBM are highlighted through examples of previous applications and suggestions for future research are made. The review focusses on applications in the midrange bracket, such as cell-cell interactions, the microcirculation, and microfluidic devices; wherein the inherent mesoscale nature of the LBM renders it well suited to the incorporation of fluid-structure interaction effects, molecular/particle interactions and interfacial dynamics. The review demonstrates that the LBM has the potential to become a valuable tool across a range of emerging areas in bio-CFD, such as understanding and predicting disease, designing lab-on-a-chip devices, and elucidating complex biological processes.
Collapse
Affiliation(s)
- Joseph O'Connor
- School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, Manchester, UKM13 9PL.
| | | | | | | |
Collapse
|
10
|
Classification of Unsteady Flow Patterns in a Rotodynamic Blood Pump: Introduction of Non-Dimensional Regime Map. Cardiovasc Eng Technol 2015; 6:230-41. [DOI: 10.1007/s13239-015-0231-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2015] [Accepted: 06/22/2015] [Indexed: 11/25/2022]
|
11
|
Gester K, Jansen SV, Stahl M, Steinseifer U. A Simple Method for the Investigation of Cell Separation Effects of Blood With Physiological Hematocrit Values. Artif Organs 2014; 39:432-40. [DOI: 10.1111/aor.12402] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Kathrin Gester
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Sebastian V. Jansen
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Marion Stahl
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| |
Collapse
|
12
|
Amaral F, Egger C, Steinseifer U, Schmitz-Rode T. Differences between blood and a Newtonian fluid on the performance of a hydrodynamic bearing for rotary blood pumps. Artif Organs 2013; 37:786-92. [PMID: 23980561 DOI: 10.1111/aor.12166] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Assuming that blood has a constant viscosity is a common practice when designing rotary blood pumps (RBPs), where shear stresses are generally higher than in the human body. This eases the design and allows numerical simulations and bench top experiments to be performed with Newtonian fluids. However, specific flow conditions may cause a change in cell distribution leading to an apparent lower blood viscosity. It has been observed that decreasing the vessel diameters and increasing flow velocities contribute to this effect. Because a hydrodynamic bearing operates under flow conditions following this pattern, it is important to verify whether this effect also takes place when this type of bearing is applied to a RBP. Because the operation of a hydrodynamic bearing depends directly on the fluid viscosity, a local change in cell distribution in the bearing gap can be reflected in changes in the bearing performance. In this work, a spiral groove hydrodynamic bearing was tested with porcine blood in a specially built test rig. The generated suspension force, cross flow, and bearing torque were recorded and compared with the reference response when using a solution of water and glycerol. Experiments with porcine blood yielded lower suspension forces, lower flows, and lower bearing torques than when using the glycerol solution. An explanation could be a lower apparent viscosity due to inhomogeneity of blood cell concentrations. Therefore, it is crucial to consider the effective blood viscosity when designing hydrodynamic bearings for RBPs and performing experiments.
Collapse
Affiliation(s)
- Felipe Amaral
- Cardiovascular Engineering, Helmholtz Institute, Aachen, Germany
| | | | | | | |
Collapse
|
13
|
Fraser KH, Zhang T, Taskin ME, Griffith BP, Wu ZJ. A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index. J Biomech Eng 2012; 134:081002. [PMID: 22938355 PMCID: PMC5413114 DOI: 10.1115/1.4007092] [Citation(s) in RCA: 214] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 06/18/2012] [Indexed: 12/31/2022]
Abstract
Ventricular assist devices (VADs) have already helped many patients with heart failure but have the potential to assist more patients if current problems with blood damage (hemolysis, platelet activation, thrombosis and emboli, and destruction of the von Willebrand factor (vWf)) can be eliminated. A step towards this goal is better understanding of the relationships between shear stress, exposure time, and blood damage and, from there, the development of numerical models for the different types of blood damage to enable the design of improved VADs. In this study, computational fluid dynamics (CFD) was used to calculate the hemodynamics in three clinical VADs and two investigational VADs and the shear stress, residence time, and hemolysis were investigated. A new scalar transport model for hemolysis was developed. The results were compared with in vitro measurements of the pressure head in each VAD and the hemolysis index in two VADs. A comparative analysis of the blood damage related fluid dynamic parameters and hemolysis index was performed among the VADs. Compared to the centrifugal VADs, the axial VADs had: higher mean scalar shear stress (sss); a wider range of sss, with larger maxima and larger percentage volumes at both low and high sss; and longer residence times at very high sss. The hemolysis predictions were in agreement with the experiments and showed that the axial VADs had a higher hemolysis index. The increased hemolysis in axial VADs compared to centrifugal VADs is a direct result of their higher shear stresses and longer residence times. Since platelet activation and destruction of the vWf also require high shear stresses, the flow conditions inside axial VADs are likely to result in more of these types of blood damage compared with centrifugal VADs.
Collapse
Affiliation(s)
| | | | | | | | - Zhongjun J. Wu
- e-mail:
- Artificial Organs Laboratory,
University of Maryland School of Medicine,
MSTF rm 436, 10 S. Pine Street,
Baltimore, MD 21201
| |
Collapse
|
14
|
Girdhar G, Xenos M, Alemu Y, Chiu WC, Lynch BE, Jesty J, Einav S, Slepian MJ, Bluestein D. Device thrombogenicity emulation: a novel method for optimizing mechanical circulatory support device thromboresistance. PLoS One 2012; 7:e32463. [PMID: 22396768 PMCID: PMC3292570 DOI: 10.1371/journal.pone.0032463] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2011] [Accepted: 01/27/2012] [Indexed: 12/22/2022] Open
Abstract
Mechanical circulatory support (MCS) devices provide both short and long term hemodynamic support for advanced heart failure patients. Unfortunately these devices remain plagued by thromboembolic complications associated with chronic platelet activation--mandating complex, lifelong anticoagulation therapy. To address the unmet need for enhancing the thromboresistance of these devices to extend their long term use, we developed a universal predictive methodology entitled Device Thrombogenicity Emulation (DTE) that facilitates optimizing the thrombogenic performance of any MCS device--ideally to a level that may obviate the need for mandatory anticoagulation. DTE combines in silico numerical simulations with in vitro measurements by correlating device hemodynamics with platelet activity coagulation markers--before and after iterative design modifications aimed at achieving optimized thrombogenic performance. DTE proof-of-concept is demonstrated by comparing two rotary Left Ventricular Assist Devices (LVADs) (DeBakey vs HeartAssist 5, Micromed Houston, TX), the latter a version of the former following optimization of geometrical features implicated in device thrombogenicity. Cumulative stresses that may drive platelets beyond their activation threshold were calculated along multiple flow trajectories and collapsed into probability density functions (PDFs) representing the device 'thrombogenic footprint', indicating significantly reduced thrombogenicity for the optimized design. Platelet activity measurements performed in the actual pump prototypes operating under clinical conditions in circulation flow loops--before and after the optimization with the DTE methodology, show an order of magnitude lower platelet activity rate for the optimized device. The robust capability of this predictive technology--demonstrated here for attaining safe and cost-effective pre-clinical MCS thrombo-optimization--indicates its potential for reducing device thrombogenicity to a level that may significantly limit the extent of concomitant antithrombotic pharmacotherapy needed for safe clinical device use.
Collapse
Affiliation(s)
- Gaurav Girdhar
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America
| | - Michalis Xenos
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America
| | - Yared Alemu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America
| | - Wei-Che Chiu
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America
| | - Bryan E. Lynch
- MicroMed Cardiovascular Inc., Houston, Texas, United States of America
| | - Jolyon Jesty
- Department of Hematology, Stony Brook University, Stony Brook, New York, United States of America
| | - Shmuel Einav
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America
| | - Marvin J. Slepian
- Sarver Heart Center, University of Arizona, Tucson, Arizona, United States of America
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, United States of America
| |
Collapse
|
15
|
Fraser KH, Taskin ME, Griffith BP, Wu ZJ. The use of computational fluid dynamics in the development of ventricular assist devices. Med Eng Phys 2011; 33:263-80. [PMID: 21075669 PMCID: PMC3053072 DOI: 10.1016/j.medengphy.2010.10.014] [Citation(s) in RCA: 147] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2010] [Revised: 10/12/2010] [Accepted: 10/15/2010] [Indexed: 02/06/2023]
Abstract
Progress in the field of prosthetic cardiovascular devices has significantly contributed to the rapid advancements in cardiac therapy during the last four decades. The concept of mechanical circulatory assistance was established with the first successful clinical use of heart-lung machines for cardiopulmonary bypass. Since then a variety of devices have been developed to replace or assist diseased components of the cardiovascular system. Ventricular assist devices (VADs) are basically mechanical pumps designed to augment or replace the function of one or more chambers of the failing heart. Computational Fluid Dynamics (CFD) is an attractive tool in the development process of VADs, allowing numerous different designs to be characterized for their functional performance virtually, for a wide range of operating conditions, without the physical device being fabricated. However, VADs operate in a flow regime which is traditionally difficult to simulate; the transitional region at the boundary of laminar and turbulent flow. Hence different methods have been used and the best approach is debatable. In addition to these fundamental fluid dynamic issues, blood consists of biological cells. Device-induced biological complications are a serious consequence of VAD use. The complications include blood damage (haemolysis, blood cell activation), thrombosis and emboli. Patients are required to take anticoagulation medication constantly which may cause bleeding. Despite many efforts blood damage models have still not been implemented satisfactorily into numerical analysis of VADs, which severely undermines the full potential of CFD. This paper reviews the current state of the art CFD for analysis of blood pumps, including a practical critical review of the studies to date, which should help device designers choose the most appropriate methods; a summary of blood damage models and the difficulties in implementing them into CFD; and current gaps in knowledge and areas for future work.
Collapse
Affiliation(s)
- Katharine H Fraser
- Department of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | | | | | | |
Collapse
|
16
|
Abstract
This report describes a multi-disciplinary program to develop a pediatric blood pump, motivated by the critical need to treat infants and young children with congenital and acquired heart diseases. The unique challenges of this patient population require a device with exceptional biocompatibility, miniaturized for implantation up to 6 months. This program implemented a collaborative, prescriptive design process, whereby mathematical models of the governing physics were coupled with numerical optimization to achieve a favorable compromise among several competing design objectives. Computational simulations of fluid dynamics, electromagnetics, and rotordynamics were performed in two stages: first using reduced-order formulations to permit rapid optimization of the key design parameters; followed by rigorous CFD and FEA simulations for calibration, validation, and detailed optimization. Over 20 design configurations were initially considered, leading to three pump topologies, judged on the basis of a multi-component analysis including criteria for anatomic fit, performance, biocompatibility, reliability, and manufacturability. This led to fabrication of a mixed-flow magnetically levitated pump, the PF3, having a displaced volume of 16.6 cc, approximating the size of a AA battery and producing a flow capacity of 0.3-1.5 L/min. Initial in vivo evaluation demonstrated excellent hemocompatibility after 72 days of implantation in an ovine. In summary, combination of prescriptive and heuristic design principles have proven effective in developing a miniature magnetically levitated blood pump with excellent performance and biocompatibility, suitable for integration into chronic circulatory support system for infants and young children; aiming for a clinical trial within 3 years.
Collapse
|
17
|
Wu J, Paden BE, Borovetz HS, Antaki JF. Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device. Artif Organs 2009; 34:402-11. [PMID: 19832736 DOI: 10.1111/j.1525-1594.2009.00875.x] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
An important challenge facing the design of turbodynamic ventricular assist devices (VADs) intended for long-term support is the optimization of the flow path geometry to maximize hydraulic performance while minimizing shear-stress-induced hemolysis and thrombosis. For unshrouded centrifugal, mixed-flow and axial-flow blood pumps, the complex flow patterns within the blade tip clearance between the lengthwise upper surface of the rotating impeller blades and the stationary pump housing have a dramatic effect on both the hydrodynamic performance and the blood damage production. Detailed computational fluid dynamics (CFD) analyses were performed in this study to investigate such flow behavior in blade tip clearance region for a centrifugal blood pump representing a scaled-up version of a prototype pediatric VAD. Nominal flow conditions were analyzed at a flow rate of 2.5 L/min and rotor speed of 3000 rpm with three blade tip clearances of 50, 100, and 200 microm. CFD simulations predicted a decrease in the averaged tip leakage flow rate and an increase in pump head and axial thrust with decreasing blade tip clearances from 200 to 50 microm. The predicted hemolysis, however, exhibited a unimodal relationship, having a minimum at 100 microm compared to 50 microm and 200 microm. Experimental data corroborate these predictions. Detailed flow patterns observed in this study revealed interesting fluid dynamic features associated with the blade tip clearances, such as the generation and dissipation of tip leakage vortex and its interaction with the primary flow in the blade-blade passages. Quantitative calculations suggested the existence of an optimal blade tip clearance by which hydraulic efficiency can be maximized and hemolysis minimized.
Collapse
Affiliation(s)
- Jingchun Wu
- LaunchPoint Technologies LLC, Goleta, California, USA
| | | | | | | |
Collapse
|
18
|
Kim NJ, Diao C, Ahn KH, Lee SJ, Kameneva MV, Antaki JF. Parametric study of blade tip clearance, flow rate, and impeller speed on blood damage in rotary blood pump. Artif Organs 2009; 33:468-74. [PMID: 19473143 DOI: 10.1111/j.1525-1594.2009.00754.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Phenomenological studies on mechanical hemolysis in rotary blood pumps have provided empirical relationships that predict hemoglobin release as an exponential function of shear rate and time. However, these relations are not universally valid in all flow circumstances, particularly in small gap clearances. The experiments in this study were conducted at multiple operating points based on flow rate, impeller speed, and tip gap clearance. Fresh bovine red blood cells were resuspended in phosphate-buffered saline at about 30% hematocrit, and circulated for 30 min in a centrifugal blood pump with a variable tip gap, designed specifically for these studies. Blood damage indices were found to increase with increased impeller speed or decreased flow rate. The hemolysis index for 50-microm tip gap was found to be less than 200-microm gap, despite increased shear rate. This is explained by a cell screening effect that prevents cells from entering the smaller gap. It is suggested that these parameters should be reflected in the hemolysis model not only for the design, but for the practical use of rotary blood pumps, and that further investigation is needed to explore other possible factors contributing to hemolysis.
Collapse
Affiliation(s)
- Nahn Ju Kim
- School of Chemical and Biological Engineering, Seoul National University, Seoul, Republic of Korea
| | | | | | | | | | | |
Collapse
|