1
|
Arzehgar A, Seyedhasani SN, Ahmadi FB, Bagheri Baravati F, Sadeghi Hesar A, Kachooei AR, Aalaei S. Sensor-based technologies for motion analysis in sports injuries: a scoping review. BMC Sports Sci Med Rehabil 2025; 17:15. [PMID: 39885587 PMCID: PMC11780775 DOI: 10.1186/s13102-025-01063-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2024] [Accepted: 01/20/2025] [Indexed: 02/01/2025]
Abstract
BACKGROUND Insightful motion analysis provides valuable information for athlete health, a crucial aspect of sports medicine. This systematic review presents an analytical overview of the use of various sensors in motion analysis for sports injury assessment. METHODS A comprehensive search of PubMed/MEDLINE, Scopus, and Web of Science was conducted in February 2024 using search terms related to "sport", "athlete", "sensor-based technology", "motion analysis", and "injury." Studies were included based on PCC (Participants, Concept, Context) criteria. Key data, including sensor types, motion data processing methods, injury and sport types, and application areas, were extracted and analyzed. RESULTS Forty-two studies met the inclusion criteria. Inertial measurement unit (IMU) sensors were the most commonly used for motion data collection. Sensor fusion techniques have gained traction, particularly for rehabilitation assessment. Knee injuries and joint sprains were the most frequently studied injuries, with statistical methods being the predominant approach to data analysis. CONCLUSIONS This review comprehensively explains sensor-based techniques in sports injury motion analysis. Significant research gaps, including the integration of advanced processing techniques, real-world applicability, and the inclusion of underrepresented domains such as adaptive sports, highlight opportunities for innovation. Bridging these gaps can drive the development of more effective, accessible, and personalized solutions in sports health.
Collapse
Affiliation(s)
- Afrooz Arzehgar
- Department of medical informatics, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Seyedeh Nahid Seyedhasani
- Department of medical informatics, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Fatemeh Baharvand Ahmadi
- Department of medical informatics, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Fatemeh Bagheri Baravati
- Department of medical informatics, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Alireza Sadeghi Hesar
- Department of medical informatics, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Shokoufeh Aalaei
- Department of medical informatics, Faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
- Bioinformatics Research Center, Basic Sciences Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
2
|
Apte S, Karami H, Vallat C, Gremeaux V, Aminian K. In-field assessment of change-of-direction ability with a single wearable sensor. Sci Rep 2023; 13:4518. [PMID: 36934121 PMCID: PMC10024719 DOI: 10.1038/s41598-023-30773-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 02/28/2023] [Indexed: 03/20/2023] Open
Abstract
The Agility T-test is a standardized method to measure the change-of-direction (COD) ability of athletes in the field. It is traditionally scored based on the total completion time, which does not provide information on the different CODs. Augmenting the T-test with wearable sensors provides the opportunity to explore new metrics. Towards this, data of 23 professional soccer players were recorded with a trunk-worn GNSS-IMU (Global Navigation Satellite System-Inertial Measurement Unit) device. A method for detecting the four CODs based on the wavelet-denoised antero-posterior acceleration signal was developed and validated using video data (60 Hz). Following this, completion time was estimated using GNSS ground speed and validated with the photocell data. The proposed method yields an error (mean ± standard deviation) of 0 ± 66 ms for the COD detection, - 0.16 ± 0.22 s for completion time, and a relative error for each COD duration and each sequential movement durations of less than 3.5 ± 16% and 7 ± 7%, respectively. The presented algorithm can highlight the asymmetric performance between the phases and CODs in the right and left direction. By providing a more comprehensive analysis in the field, this work can enable coaches to develop more personalized training and rehabilitation programs.
Collapse
Affiliation(s)
- Salil Apte
- Laboratory of Movement Analysis and Measurement, 1015, Lausanne, Switzerland.
| | - Hojjat Karami
- Laboratory of Movement Analysis and Measurement, 1015, Lausanne, Switzerland
| | - Célestin Vallat
- Laboratory of Movement Analysis and Measurement, 1015, Lausanne, Switzerland
| | - Vincent Gremeaux
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
| | - Kamiar Aminian
- Laboratory of Movement Analysis and Measurement, 1015, Lausanne, Switzerland
| |
Collapse
|
3
|
Marques JB, Auliffe SM, Thomson A, Sideris V, Santiago P, Read PJ. The use of wearable technology as an assessment tool to identify between-limb differences during functional tasks following ACL reconstruction. A scoping review. Phys Ther Sport 2022; 55:1-11. [PMID: 35131534 DOI: 10.1016/j.ptsp.2022.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/23/2022] [Accepted: 01/24/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To report how wearable sensors have been used to identify between-limb deficits during functional tasks following ACL reconstruction and critically examine the methods used. METHODS We performed a scoping review of studies including participants with ACL reconstruction as the primary surgical procedure, who were assessed using wearable sensors during functional movement tasks (e.g., balance, walking or running, jumping and landing) at all postsurgical time frames. RESULTS Eleven studies met the inclusion criteria. The majority examined jumping-landing tasks and reported kinematic and kinetic differences between limbs (involved vs. unninvolved) and groups (injured vs. controls). Excellent reliability and moderate-strong agreement with laboratory protocols was indicated, with IMU sensors providing an accurate estimation of kinetics, but the number of studies and range of tasks used were limited. Methodological differences were present including, sensor placement, sampling rate, time post-surgery and type of assessment which appear to affect the outcome. CONCLUSIONS Wearable sensors consistently identified between-limb and group deficits following ACL reconstruction. Preliminary evidence suggests these technologies could be used to monitor knee function during rehabilitation, but further research is needed including, validation against criterion measures. Practitioners should also consider how the methods used can affect the accuracy of the outcome.
Collapse
Affiliation(s)
- Joao B Marques
- University of Sao Paulo, Faculty of Medicine, Rehabilitation and Functional Performance Program, Ribeirao Preto, Sao Paulo, Brazil
| | - Sean Mc Auliffe
- School of Medicine, Discipline of Physiotherapy, Trinity College, Dublin, Ireland
| | - Athol Thomson
- Aspetar - Orthopaedic and Sports Medicine Hospital, Doha, Qatar
| | | | - Paulo Santiago
- University of Sao Paulo, Biomechanics and Motor Control Lab (LaBioCoM), School of Physical Education and Sport, Ribeirão Preto, Sao Paulo, Brazil
| | - Paul J Read
- Institute of Sport Exercise and Health, London, UK; Division of Surgery & Interventional Science, University College London, UK; School of Sport and Exercise Sciences, University of Gloucestershire, UK.
| |
Collapse
|
4
|
Preatoni E, Bergamini E, Fantozzi S, Giraud LI, Orejel Bustos AS, Vannozzi G, Camomilla V. The Use of Wearable Sensors for Preventing, Assessing, and Informing Recovery from Sport-Related Musculoskeletal Injuries: A Systematic Scoping Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:3225. [PMID: 35590914 PMCID: PMC9105988 DOI: 10.3390/s22093225] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/13/2022] [Accepted: 04/18/2022] [Indexed: 02/06/2023]
Abstract
Wearable technologies are often indicated as tools that can enable the in-field collection of quantitative biomechanical data, unobtrusively, for extended periods of time, and with few spatial limitations. Despite many claims about their potential for impact in the area of injury prevention and management, there seems to be little attention to grounding this potential in biomechanical research linking quantities from wearables to musculoskeletal injuries, and to assessing the readiness of these biomechanical approaches for being implemented in real practice. We performed a systematic scoping review to characterise and critically analyse the state of the art of research using wearable technologies to study musculoskeletal injuries in sport from a biomechanical perspective. A total of 4952 articles were retrieved from the Web of Science, Scopus, and PubMed databases; 165 were included. Multiple study features-such as research design, scope, experimental settings, and applied context-were summarised and assessed. We also proposed an injury-research readiness classification tool to gauge the maturity of biomechanical approaches using wearables. Five main conclusions emerged from this review, which we used as a springboard to propose guidelines and good practices for future research and dissemination in the field.
Collapse
Affiliation(s)
- Ezio Preatoni
- Department for Health, University of Bath, Bath BA2 7AY, UK; (E.P.); (L.I.G.)
- Centre for Health and Injury and Illness Prevention in Sport, University of Bath, Bath BA2 7AY, UK
| | - Elena Bergamini
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Silvia Fantozzi
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi”, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;
- Health Sciences and Technologies—Interdepartmental Centre for Industrial Research, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy
| | - Lucie I. Giraud
- Department for Health, University of Bath, Bath BA2 7AY, UK; (E.P.); (L.I.G.)
| | - Amaranta S. Orejel Bustos
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Giuseppe Vannozzi
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Valentina Camomilla
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| |
Collapse
|
5
|
Zou L, Yang Y, Wang Y. A Meta-Analysis of Systemic Evaluation of Knee Ligament Injury or Intervention of Knee Proprioceptive Function Recovery. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:9129284. [PMID: 35222897 PMCID: PMC8872686 DOI: 10.1155/2022/9129284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/26/2021] [Accepted: 12/17/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The knee ligaments, as a passive knee joint stability device, provide protection for the knee joint and ensure its functional integrity. This role has long been known and recognized by people. The original purpose of knee ligament reconstruction after knee ligament injury is to restore its anatomical structure and mechanical stability mechanism. METHODS Taking athletes as the research object, randomized controlled trials (RCTs) on improving ankle joint function of athletes related to proprioception training at home and abroad were included. The search time was from the establishment of the database to December 31, 2019, and the references of related documents were traced. Two researchers independently screened the literature, extracted data, and evaluated the quality of the literature. RevMan 5.3 software was used for data analysis. RESULTS The extensor strength, flexor strength, and flexor strength/extensor strength of the affected limb were higher than before the operation one year after surgery (P < 0.01). The Lysholm score, Lysholm instability score, and one-foot jump distance were all higher than those before surgery (P < 0.05); the difference of KT-2000 for both knees was smaller than that before surgery (P < 0.05). CONCLUSION In maintaining the anterior stability of the knee joint, the knee ligament provides 85% static resistance to prevent the tibia from moving forward, so knee ligament injury will cause knee instability. The proprioceptive feedback mechanism plays an important role in maintaining the functional stability of joints.
Collapse
Affiliation(s)
- Longqiang Zou
- Department of Sports Medical, Ganzhou People's Hospital and the Affiliated Ganzhou Hospital of Nanchang University, Ganzhou 341000, Jiangxi, China
| | - Yibin Yang
- Department of Sports Medical, Ganzhou People's Hospital and the Affiliated Ganzhou Hospital of Nanchang University, Ganzhou 341000, Jiangxi, China
| | - Yihai Wang
- Department of Sports Medical, Ganzhou People's Hospital and the Affiliated Ganzhou Hospital of Nanchang University, Ganzhou 341000, Jiangxi, China
| |
Collapse
|