1
|
Puteo N, Valentino EM, Davidoni V, Tigani D. Radiological assessment of cup anteversion with a novel 3D-printed highly-porous titanium dual mobility cup. J Orthop Surg Res 2025; 20:150. [PMID: 39920807 PMCID: PMC11806696 DOI: 10.1186/s13018-025-05555-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2024] [Accepted: 01/31/2025] [Indexed: 02/09/2025] Open
Abstract
BACKGROUND Cup anteversion after primary total hip arthroplasty (THA) with monobloc dual mobility cups (DMC) is difficult to measure on anterior-posterior (AP) pelvic radiographs because of the implant radiopacity and cup design which do not allow for an accurate visualization of the radiographic projection of the cup equatorial rim and the femoral head. This study aims to radiographically investigate on the reliability and accuracy of different measurement methods for cup anteversion in monobloc DMC THA, by comparing a novel titanium cup with conventional cup designs. METHODS 97 THAs with a monobloc 3D-printed titanium DMC were radiographically assessed for cup radiographic anteversion (RA) one month postoperatively. RA were measured by three blinded observers through Lewinnek, Woo-Morrey methods and an open access mathematical software (GeoGebra), used as reference method. Intra- and interobserver reliability of RA measurements were evaluated for each method using intraclass correlation coefficient (ICC). Accuracy was assessed comparing Lewinnek and Woo-Morrey methods with GeoGebra. Moreover, further 98 THAs with conventional different brand DMC were radiographically assessed as control group by using the same methods. RESULTS ICC for intra- and interobserver reliability for RA measurements with GeoGebra, Lewinnek and Woo-Morrey methods were 0.975-0.980, 0.978 - 0.965, and 0.979 - 0.958, respectively, for the titanium DMC group. Lewinnek resulted more accurate for RA than Woo-Morrey, differing by + 0.4° (p = 0.06) and + 4.4° (p < 0.001) from GeoGebra, respectively. ICC for intra- and interobserver reliability for GeoGebra, Lewinnek and Woo-Morrey methods were 0.848 - 0.756, 0.843 - 0.801, and 0.965 - 0.958, respectively, for the control DMC group. Lewinnek and Woo-Morrey methods differed by -2.3° and + 5.1° from GeoGebra, respectively (p < 0.001). CONCLUSIONS RA measurements are more consistent, repeatable and accurate with a titanium DMC than standard DMC, due to the minor radiopacity of the former cup which enable RA measurements on AP radiographs. Conversely, RA measurements of conventional DMC are more consistent but less accurate if performed on cross-table lateral radiographs by Woo-Morrey method than AP radiographs.
Collapse
|
2
|
Annapareddy A, Mulpur P, Jayakumar T, Shende C, Prasad VBN, Reddy AVG. A Radiological Comparison of Robotic-Assisted Versus Manual Techniques in Total Hip Arthroplasty. Indian J Orthop 2024; 58:1423-1430. [PMID: 39324096 PMCID: PMC11420421 DOI: 10.1007/s43465-024-01232-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Accepted: 08/07/2024] [Indexed: 09/27/2024]
Abstract
Purpose This study investigates the radiological outcomes of robotic-assisted total hip arthroplasty (RATHA) compared to manual total hip arthroplasty (mTHA), addressing the ongoing debate on the effectiveness of RATHA in achieving superior implant positioning accuracy. Methods A prospective cohort of 212 patients (103 robotic, 109 manual) underwent THA and were evaluated for postoperative radiological outcomes, focusing on the inclination and anteversion angles of the acetabular cup. Outlier prevalence was assessed based on angles outside the defined Lewinnek safe zones. All post-operative measurements were made using the BoneNinja application. Results High inter-observer and intra-observer reliabilities were observed, validating the measurement accuracy. The mean anteversion and inclination angles in the RATHA cohort were 40.5 ± 1.5 and 24.5 ± 3.1° respectively; and the mTHA cohort were 42.1 ± 4.9 and 24.9 ± 4.5°. There was a statistically significant difference in inclination angles between the two cohorts whereas the anteversion angles showed no difference. Majority of the conventional THRs (N = 72, 55.4%) were placed outside the safe zone for anteversion. The inclination angles revealed a highly significant difference between the cohorts (p < 0.0001), with all the robotic THRs (N = 121, 100%) being placed within the safe zone for inclination, whereas only 70% (N = 91) of the conventional THRs were within the safe zone. 97.5% of RA-THRs were within 3° of the proposed plan, demonstrating high accuracy. Conclusion RATHA significantly outperforms MTHA in radiological accuracy, achieving precise acetabular cup positioning with minimal outliers. These results advocate for RATHA's adoption in THA to enhance outcome predictability and affirm its reliability and safety over manual methods.
Collapse
Affiliation(s)
- Adarsh Annapareddy
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
| | - Praharsha Mulpur
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
| | - Tarun Jayakumar
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
| | - Chethan Shende
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
| | | | - A. V. Gurava Reddy
- Sunshine Bone and Joint Institute, KIMS-Sunshine Hospitals, Hyderabad, India
| |
Collapse
|
3
|
Kaushik A, Kumar C V, Hegde A, Mathias L, Shetty V. Assessing the Reliability of Postoperative Cross-Table Radiographs Compared to CT Scans for Measuring Acetabular Anteversion Angle Following Total Hip Arthroplasty. Cureus 2024; 16:e68575. [PMID: 39371801 PMCID: PMC11449688 DOI: 10.7759/cureus.68575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/03/2024] [Indexed: 10/08/2024] Open
Abstract
AIM This study aimed to evaluate acetabular anteversion following total hip arthroplasty (THA) using cross-table lateral radiographs and CT scans and to determine the reliability of cross-table lateral radiographs compared to computed tomography (CT) scans for measuring acetabular anteversion. MATERIALS AND METHODS We conducted a cross-sectional study of patients undergoing THA at Justice K.S. Hegde Charitable Hospital, Deralakatte, Mangalore, from January 2020 to June 2021. Radiographs are typically taken in both anteroposterior (AP) and lateral views after THA. However, for this study, a cross-table lateral view was used instead of the usual lateral radiograph to measure the angle of anteversion. The anteversion was calculated using the method described by Woo and Morrey. Additionally, CT scans were performed on all patients as part of the study protocol. The anteversion measured in these scans was compared to that in the cross-table radiographs to assess the latter's reliability for routine use. The risk of radiation exposure from CT scans was minimized by adhering to the ALARA (As Low as Reasonably Achievable) principle, with only axial sections of the acetabular cup being scanned. RESULTS The results show that the radiographic acetabular anteversion and CT scan measurements have a mean difference of 0.3036. There is a positive correlation between these measurements. The p-value is not statistically significant (p=0.698). Therefore, the measurements are correlated with each other with a linear relationship (r=0.919). For anteversion measurements using the X-ray method, the mean was 27.16 degrees with a standard deviation of ±9.49. The median was 27.26 degrees, ranging from 10.27 to 42.58 degrees. In comparison, the CT method yielded a mean anteversion of 27.40 degrees with a standard deviation of ±8.50 degrees. The median was 27.64 degrees, ranging from 12.35 to 43.11 degrees. CONCLUSION Cross-table lateral radiographs are a reliable and comparable method to CT scans for measuring acetabular anteversion following total hip arthroplasty.
Collapse
Affiliation(s)
- Adhithya Kaushik
- Orthopaedics, Meenakshi Medical College Hospital and Research Institute, Kanchipuram, IND
| | - Vinay Kumar C
- Orthopaedics, K S Hegde Medical Academy, Mangalore, IND
| | - Anoop Hegde
- Orthopaedics, K S Hegde Medical Academy, Mangalore, IND
| | | | - Vikram Shetty
- Orthopaedics, K S Hegde Medical Academy, Mangalore, IND
| |
Collapse
|
4
|
Tian R, Gao X, Kong N, Li X, Li Y, Wang J, Cao Y, Shi Z, Wang K, Yang P. A new seven-axis robotic-assisted total hip arthroplasty system improves component positioning: a prospective, randomized, multicenter study. Sci Rep 2024; 14:12643. [PMID: 38825602 PMCID: PMC11144703 DOI: 10.1038/s41598-024-63624-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 05/30/2024] [Indexed: 06/04/2024] Open
Abstract
This study compared the radiologic and clinical outcomes of a new seven-axis robotic-assisted total hip arthroplasty (THA) and conventional THA. Hundred and four patients were randomly assigned to two groups-the robotic-assisted THA group (RAS group) and the conventional THA group (CON group). The preoperative and postoperative Harris Hip score (HHS), acetabular inclination, anteversion, femoral offset, and leg length discrepancy (LLD) were compared. During the follow-up, no patients had any complications that could be associated with the use of the robot. The proportion of acetabular cups in the safety zone was significantly higher in the RAS group than that in the CON group. The two groups had significantly different mean absolute difference of inclination and anteversion. There was no significant difference in the postoperative HHSs, changes in HHSs, femoral offset, and lower limb length between the two groups. The seven-axis robotic-assisted THA system is safe and effective, and leads to better acetabulum cup positioning compared to conventional THA. The improvements observed in the HHS, LLD, and femoral offset in the RAS group were similar to those in the CON group.Clinical trial registration time: 19/05/2022.Clinical trial registration number: ChiCTR2200060115.
Collapse
Affiliation(s)
- Run Tian
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Xu Gao
- Xi'an Honghui Hospital, Xi'an, China
| | - Ning Kong
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Xinghua Li
- Department of Radiology, Xi'an Jiaotong University Second Affiliated Hospital, Xi'an, China
| | - Yiyang Li
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Jian Wang
- Department of Orthopedics, Southern Medical University Nanfang Hospital, Guangzhou, China
| | - Yongping Cao
- Department of Orthopedics, Peking University First Hospital, Beijing, China
| | - Zhanjun Shi
- Department of Orthopedics, Southern Medical University Nanfang Hospital, Guangzhou, China
| | - Kunzheng Wang
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China
| | - Pei Yang
- Department of Bone and Joint, Xi'an Jiaotong University Second Affiliated Hospital, No.157, Xiwu Road, Xincheng District, Xi'an, 710004, Shaanxi, China.
| |
Collapse
|
5
|
Lee TS, Kwon HM, Park JY, Kim DK, Kang KT, Park KK. Could We Expect Postoperative Cup Anteversion after Total Hip Arthroplasty Using Postoperative Plain Anteroposterior and Lateral Radiograph? A Three-Dimensional Experimental Operation Study. J Clin Med 2023; 12:6664. [PMID: 37892802 PMCID: PMC10607240 DOI: 10.3390/jcm12206664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 09/29/2023] [Accepted: 10/19/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND A postoperative radiograph in total hip arthroplasty (THA) is usually obtained to evaluate the inclination and anteversion of the acetabular components. However, there is no gold-standard method for calculating the exact inclination and anteversion of the acetabular components on post-THA radiographs. We aimed to measure the actual anteversion of the acetabular component on postoperative radiographs by obtaining correlation data between the virtual and actual acetabular component positioning using virtual three-dimensional (3D) surgery. METHODS A total of 64 hip scans of 32 patients who underwent lower-extremity computed tomography (CT) were retrospectively reviewed. We reconstructed 3D models of the 64 hips using customized computer software (Mimics). Furthermore, to identify the safe zone of acetabular component position in THA, we performed virtual 3D surgery simulations for five anteversion (-10°, 0°, 10°, 20°, and 30°) and five inclination (20°, 30°, 40°, 50°, and 60°) types. We analyzed the acetabular anatomy using 3D models to measure the radiographic, anatomical, and operative anteversion (RA, AA, OA) and inclination (RI, AI, OI) angles. Additionally, we used the Woo-Morrey (WM) method to calculate the anteversion angle in the reconstructed cross-table lateral (CL) radiographs and determined the correlation between these measurements. RESULTS The safe zone of the acetabular component was visualized on post-THA CL radiographs using the WM method of anteversion measurement based on the different anteversions and inclinations of the acetabular component. The AA, RA, OA, OI, and WM differed significantly between males and females (p value < 0.05). As the anatomical inclination or anteversion increased, the WM anteversion measurements also increased. The radiographic anteversion measurement best matched the WM method of measurement, followed by anatomical and operative methods. CONCLUSIONS The actual anteversion of the acetabular component after THA can be measured on CL radiographs with the WM method using a 3D virtual program, with good reproducibility.
Collapse
Affiliation(s)
- Tae Sung Lee
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul 03722, Republic of Korea; (T.S.L.); (H.M.K.); (J.Y.P.); (D.K.K.)
| | - Hyuck Min Kwon
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul 03722, Republic of Korea; (T.S.L.); (H.M.K.); (J.Y.P.); (D.K.K.)
| | - Jun Young Park
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul 03722, Republic of Korea; (T.S.L.); (H.M.K.); (J.Y.P.); (D.K.K.)
| | - Dong Ki Kim
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul 03722, Republic of Korea; (T.S.L.); (H.M.K.); (J.Y.P.); (D.K.K.)
| | - Kyoung Tak Kang
- Department of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Kwan Kyu Park
- Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul 03722, Republic of Korea; (T.S.L.); (H.M.K.); (J.Y.P.); (D.K.K.)
| |
Collapse
|
6
|
Zhang W, Xu J, Li D, Sun H, Cai Z, Chen M, Ma R. Reliability and Validity of Standing Lateral Radiograph Method for Measuring Acetabular Component Version: A Modified Cross-table Lateral Radiograph Method. Orthop Surg 2022; 14:1622-1629. [PMID: 35711111 PMCID: PMC9363715 DOI: 10.1111/os.13373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 05/16/2022] [Accepted: 05/24/2022] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVES To investigate the effect of the X-ray incidence angle on cup version measurements and the reliability and validity of standing lateral (SL) radiography for measuring cup versions. METHODS Cup versions under different X-ray incidence angles were investigated by the 3D simulation analysis. Ninety-three patients, who underwent primary total hip arthroplasty (THA) with postoperative SL radiographs and CT scans between April 2020 and December 2021, were retrospectively analyzed. SL radiography was taken under naturally standing position, correcting for the measurement error of pelvic tilt in cross-table lateral (CL) radiography. Cup versions were measured on SL radiographs and CT images by two qualified orthopedic physicians. The intra- and inter-observer reliabilities were assessed by intra-class correlation coefficient. The consistency between radiographic and CT measurements was evaluated using Pearson correlation coefficient. RESULTS No significant differences in cup version measurements were observed between groups of different X-ray incidence angles (P = 0.663) in the 3D simulation analysis. All measurements had excellent intra- and inter-observer reliabilities, with an intraclass correlation coefficient of >0.95. Mean cup version measurements from SL radiographs correlated well with those from CT scans (r = 0.853, P < 0.001). The mean difference between radiographic and CT measurements was -0.49° (range -12.62° to 10.37°, SD 3.95°), and the majority of differences were within the 95% limits of agreement. CONCLUSION The cup versions measured with SL radiography were close to the CT measurements. SL radiograph method is reliable and valid for measuring acetabular component version after THA.
Collapse
Affiliation(s)
- Wenhui Zhang
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Jie Xu
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Deng Li
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Hao Sun
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Zhiqing Cai
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Meiyi Chen
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ruofan Ma
- Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
7
|
Tian R, Lei Y, Wang K, Yang P. [Comparative study of intra- and post-operative inclination and anteversion angles of acetabular cup in robot-assisted total hip arthroplasty]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:1246-1250. [PMID: 34651476 DOI: 10.7507/1002-1892.202107037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To compare the difference in the inclination and anteversion angles of the acetabular cup measured by intraoperative robot-assisted total hip arthroplasty (THA) and postoperative X-ray films and CT imaging. Methods The clinical data of 54 patients (54 hips) who underwent robot-assisted THA between May 2020 and December 2020 were retrospectively analyzed. Among them, there were 26 males (26 hips) and 28 females (28 hips), with an average age of 58.4 years (range, 39-71 years). The body mass index was 19.2-29.3 kg/m 2, with an average of 25.2 kg/m 2. All the patients had their first THA, including 31 cases of osteonecrosis of the femoral head, 12 cases of hip arthritis, 8 cases of femoral neck fracture, and 3 cases of developmental dysplasia of the hip. The anteversion and inclination angles of the acetabular cup were obtained through the surgical data in the robot host system. All patients underwent X-ray and CT scan examination within 2-7 days after operation to obtain the postoperative anteversion and inclination angles of the acetabular cup. According to the concept of "Lewinnek safe zone", the proportion of acetabular in the safe zone intra- and post-operation were compared. Results The operation time was 57.8-89.2 minutes, with an average of 68.3 minutes; the intraoperative blood loss was 125.0-450.0 mL, with an average of 204.8 mL. No adverse events such as dislocation of hip joint and infection occurred during hospitalization. The anteversion angle of acetabular cup was (40.8±0.6)° during operation and (41.2±2.8)° after operation, with no significant difference ( t=1.026, P=0.307). The anteversion angle of acetabular cup measured during operation was (17.6±1.4)°, which was significantly smaller than that measured after operation (23.4±3.8)°( t=10.520, P=0.000). According to "Lewinnek safe zone", 54 hips (100%) were in the safety zone during operation, and 16 hips were out of the safety zone, 38 hips were in the safty zone after operation, the ratio of the hips in the safty zone was 70.4%, showing a significant difference ( χ 2=18.783, P=0.000). Conclusion Robot-assisted THA can obtain accurate placement of the acetabular cup, but there is a large deviation between the anteversion angle of the acetabular cup in the lateral position during operation and the supine position after operation. Further study is needed to define the intraoperative placement position of the acetabular cup.
Collapse
Affiliation(s)
- Run Tian
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an Shaanxi, 710004, P.R.China
| | - Yutian Lei
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an Shaanxi, 710004, P.R.China
| | - Kunzheng Wang
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an Shaanxi, 710004, P.R.China
| | - Pei Yang
- Department of Bone and Joint Surgery, the Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an Shaanxi, 710004, P.R.China
| |
Collapse
|
8
|
Goyal T, Paul S, Choudhury AK, Gupta T. Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans. Clin Orthop Surg 2021; 13:329-335. [PMID: 34484625 PMCID: PMC8380526 DOI: 10.4055/cios20274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/19/2020] [Accepted: 12/28/2020] [Indexed: 11/29/2022] Open
Abstract
Background Several methods of measurement of anteversion of acetabular components after total hip arthroplasty (THA) have been described in the literature using plain radiographs or computed tomography (CT) scans. None of these have proved to be the gold standard. We aimed to study the correlation between the CT and radiographic methods of calculation of acetabulum anteversion. Methods CT scans of the pelvis, anteroposterior (AP) and cross-table lateral (CL) radiographs were obtained in 60 patients who underwent THA two weeks after surgery. Anteversion was measured using Widmer method and Liaw method on AP radiographs, and the ischiolateral method on CL radiographs. Anteversion measured on the CT scan was taken as the reference anteversion and the above measurements were analysed for correlation with the measurements on CT scan. Intraclass correlation coefficients (ICCs) were calculated for both intra- and interobserver reliability. Results Mean acetabular version on CL radiographs was 53.1 ± 10.7. Mean version on AP radiographs by Widmer method was 21.4 ± 3.6 and by Liaw method was 20.3 ± 4.8. Mean version on CT scans was 26.02 ± 6.8. There was a good correlation between the acetabular version on CT scans with the version on AP radiographs by Widmer method (r = 0.78, p < 0.001) and Liaw method (r = 0.87, p < 0.001). Good correlation was seen between the acetabular version on CL radiographs and CT scans (r = 0.91, p < 0.001). Also, a good correlation was observed between the acetabular version measurements on CL radiographs and AP radiographs by Widmer method (r = 0.81, p < 0.001) or Liaw method (r = 0.70, p < 0.001). Excellent inter- and intraobserver reliability were seen for all the measurements. Conclusions Calculation of acetabular component version on AP views as well as CL views of plain radiographs showed a strong correlation with the version measurements on CT scans. Good correlations were observed between different techniques of measurement on radiographs. Therefore, all these measurements can be valid methods for assessment of anteversion.
Collapse
Affiliation(s)
- Tarun Goyal
- Department of Orthopaedics, All India Institute of Medical Sciences, Bathinda, India
| | - Souvik Paul
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India
| | | | - Tushar Gupta
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India
| |
Collapse
|
9
|
Bracey DN, Hegde V, Shimmin AJ, Jennings JM, Pierrepont JW, Dennis DA. Spinopelvic mobility affects accuracy of acetabular anteversion measurements on cross-table lateral radiographs. Bone Joint J 2021; 103-B:59-65. [PMID: 34192919 DOI: 10.1302/0301-620x.103b7.bjj-2020-2284.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL measurements may differ by > 10° from CT scan measurements but the reasons for this discrepancy are poorly understood. Anteversion measurements from CTL radiographs and CT scans are compared to identify spinopelvic parameters predictive of inaccuracy. METHODS THA patients (n = 47; 27 males, 20 females; mean age 62.9 years (SD 6.95)) with preoperative spinopelvic mobility, radiological analysis, and postoperative CT scans were retrospectively reviewed. Acetabular component anteversion was measured on postoperative CTL radiographs and CT scans using 3D reconstructions of the pelvis. Two cohorts were identified based on a CTL-CT error of ≥ 10° (n = 11) or < 10° (n = 36). Spinopelvic mobility parameters were compared using independent-samples t-tests. Correlation between error and mobility parameters were assessed with Pearson's coefficient. RESULTS Patients with CTL error > 10° (10° to 14°) had stiffer lumbar spines with less mean lumbar flexion (38.9°(SD 11.6°) vs 47.4° (SD 13.1°); p = 0.030), different sagittal balance measured by pelvic incidence-lumbar lordosis mismatch (5.9° (SD 18.8°) vs -1.7° (SD 9.8°); p = 0.042), more pelvic extension when seated (pelvic tilt -9.7° (SD 14.1°) vs -2.2° (SD 13.2°); p = 0.050), and greater change in pelvic tilt between supine and seated positions (12.6° (SD 12.1°) vs 4.7° (SD 12.5°); p = 0.036). The CTL measurement error showed a positive correlation with increased CTL anteversion (r = 0.5; p = 0.001), standing lordosis (r = 0.23; p = 0.050), seated lordosis (r = 0.4; p = 0.009), and pelvic tilt change between supine and step-up positions (r = 0.34; p = 0.010). CONCLUSION Differences in spinopelvic mobility may explain the variability of acetabular anteversion measurements made on CTL radiographs. Patients with stiff spines and increased compensatory pelvic movement have less accurate measurements on CTL radiographs. Flexion of the contralateral hip is required to obtain clear CTL radiographs. In patients with lumbar stiffness, this movement may extend the pelvis and increase anteversion of the acetabulum on CTL views. Reliable analysis of acetabular component anteversion in this patient population may require advanced imaging with a CT scan. Cite this article: Bone Joint J 2021;103-B(7 Supple B):59-65.
Collapse
Affiliation(s)
- Daniel N Bracey
- Department of Orthopaedic Surgery, University of North Carolina, Chapel Hill, North Carolina, USA.,Colorado Joint Replacement, Denver, Colorado, USA
| | - Vishal Hegde
- Colorado Joint Replacement, Denver, Colorado, USA.,Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, Maryland, USA
| | | | - Jason M Jennings
- Colorado Joint Replacement, Denver, Colorado, USA.,Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA
| | | | - Douglas A Dennis
- Colorado Joint Replacement, Denver, Colorado, USA.,Department of Mechanical and Materials Engineering, University of Denver, Denver, Colorado, USA.,Department of Biomedical Engineering, University of Tennessee, Knoxville, Tennessee, USA.,Department of Orthopaedic Surgery, University of Colorado School of Medicine, Aurora, Colorado, USA
| |
Collapse
|
10
|
Murphy MP, Killen CJ, Ralles SJ, Brown NM, Song AJ, Wu K. The area method for measuring acetabular cup anteversion: An accurate and autonomous solution. J Clin Orthop Trauma 2021; 18:61-65. [PMID: 33996450 PMCID: PMC8099551 DOI: 10.1016/j.jcot.2021.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Accepted: 04/03/2021] [Indexed: 11/18/2022] Open
Abstract
Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty have been described, all time-consuming and with varying reproducibility. This study aimed to compare the recently proposed Area method to true cup anteversion as determined by an accelerometer. This study further applied this method programmatically to autonomously determine radiographic cup orientation using two computer programs, then compared these results to hand and accelerometer measurements. 160 anteroposterior pelvis radiographs were taken of a standard Sawbones® pelvis fitted with a total hip arthroplasty system. The acetabular cup was re-oriented between each radiograph, with anteversion ranging from 0° to 90°. An accelerometer was mounted to the cup to measure true cup anteversion. Radiographic anteversion was independently measured via three methods: by hand, linear image processing, and machine learning. Measurements were compared to triaxial accelerometer recordings. Coefficient of determination (R2) was found to be 0.997, 0.991, and 0.989 for hand measurements, the machine learning, and linear image processing, respectively. The machine learning program and hand measurements overestimated anteversion by 0.70° and 0.02° respectively. The program using linear techniques underestimated anteversion by 5.02°. Average runtime was 0.03 and 0.59 s for the machine learning and linear image processing program, respectively. The machine learning program averaged within 1° of cup orientation given a true cup anteversion less than 51°, and within 2° given an anteversion less than 85°. The Area method showed great accuracy and reliability with hand measurements compared to true anteversion. The results of this study support the use of machine learning for accurate, timely, autonomous assessment of cup orientation.
Collapse
Affiliation(s)
- Michael P. Murphy
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
- Corresponding author.
| | - Cameron J. Killen
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
| | - Steven J. Ralles
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
| | - Nicholas M. Brown
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
| | - Albert J. Song
- Loyola University Medical Center, Department of Radiology, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
| | - Karen Wu
- Loyola University Medical Center, Department of Orthopaedic Surgery and Rehabilitation, 2160 S. First Avenue,Maguire Suite 1700, Maywood, IL 60153, USA
| |
Collapse
|
11
|
Abstract
STUDY DESIGN Retrospective Cohort. SUMMARY OF BACKGROUND DATA Studies have shown that lumbar fusion procedures are associated with an increased risk of total hip arthroplasty (THA) dislocation. Some have speculated that the increased risk of dislocation is caused by mispositioning of the acetabular component because of spinal sagittal imbalance. Unfortunately, the exact relationship between spinal sagittal balance and cup orientation is unknown. OBJECTIVE The objective of this study was to investigate the effect of spinal sagittal alignment on cup anteversion in THA dislocation. METHODS Patients that suffered a THA dislocation were retrospectively identified. Cross-table lateral hip radiographs were used to measure cup anteversion with normal acetabular anteversion defined as 15±10 degrees. Lateral lumbar spine radiographs were used to measure lumbar lordosis (LL), pelvic incidence (PI), pelvic tilt, and sacral slope. Normal sagittal balance was defined as a PI-LL difference of <10 degrees. The association between sagittal balance and THA characteristics was assessed using Pearson correlation coefficient, χ analysis, and independent t tests. RESULTS A total of 29 patients had full radiographic imaging. Among these patients, 62.1% dislocated following a primary THA and 37.9% following a revision THA. Abnormal spinal sagittal balance was identified in 20 patients (69.0%). Eight (27.6%) patients had undergone spinal fusion prior to THA. Abnormal cup anteversion was demonstrated in 51.7% of all patients. Presence of a spinal fusion was not associated with cup anteversion, sagittal balance, or time to dislocation. Sagittal balance was not associated with direction of dislocation, time to dislocation, or cup anteversion. CONCLUSIONS A majority of patients with a THA dislocation demonstrated abnormal sagittal balance. However, sagittal balance was not associated with acetabular cup anteversion. As such, the relationship between spinal deformity and dislocation rates after THA may not be because of inaccurate cup orientation.
Collapse
|
12
|
Blakeney WG, Beaulieu Y, Puliero B, Lavigne M, Roy A, Massé V, Vendittoli PA. Excellent results of large-diameter ceramic-on-ceramic bearings in total hip arthroplasty. Bone Joint J 2018; 100-B:1434-1441. [DOI: 10.1302/0301-620x.100b11.bjj-2018-0532.r1] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Aims This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41.
Collapse
Affiliation(s)
- W. G. Blakeney
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada; Albany Health Campus, Albany, Australia
| | - Y. Beaulieu
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada
| | - B. Puliero
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada
| | - M. Lavigne
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada; Department of Surgery, Université de Montréal, Montréal, Canada
| | - A. Roy
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada; Department of Surgery, Université de Montréal, Montréal, Canada
| | - V. Massé
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada; Department of Surgery, Université de Montréal, Montréal, Canada
| | - P-A. Vendittoli
- Department of Surgery, CIUSSS-de-L’Est-de-L’Ile-de-Montréal, Hôpital Maisonneuve Rosemont, Montréal, Canada; Department of Surgery, Université de Montréal, Montréal, Canada
| |
Collapse
|
13
|
Teeter MG, Lanting BA, Naudie DD, McCalden RW, Howard JL, MacDonald SJ. Highly crosslinked polyethylene wear rates and acetabular component orientation: a minimum ten-year follow-up. Bone Joint J 2018; 100-B:891-897. [PMID: 29954202 DOI: 10.1302/0301-620x.100b7.bjj-2017-1457.r3] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Aims The aim of this study was to determine whether there is a difference in the rate of wear between acetabular components positioned within and outside the 'safe zones' of anteversion and inclination angle. Patients and Methods We reviewed 100 hips in 94 patients who had undergone primary total hip arthroplasty (THA) at least ten years previously. Patients all had the same type of acetabular component with a bearing couple which consisted of a 28 mm cobalt-chromium head on a highly crosslinked polyethylene (HXLPE) liner. A supine radiostereometric analysis (RSA) examination was carried out which acquired anteroposterior (AP) and lateral paired images. Acetabular component anteversion and inclination angles were measured as well as total femoral head penetration, which was divided by the length of implantation to determine the rate of polyethylene wear. Results The mean anteversion angle was 19.4° (-15.2° to 48°, sd 11.4°), the mean inclination angle 43.4° (27.3° to 60.5°, sd 6.6°), and the mean wear rate 0.055 mm/year (sd 0.060). Exactly half of the hips were positioned inside the 'safe zone'. There was no difference (median difference, 0.012 mm/year; p = 0.091) in the rate of wear between acetabular components located within or outside the 'safe zone'. When compared to acetabular components located inside the 'safe zone', the wear rate was no different for acetabular components that only achieved the target anteversion angle (median difference, 0.012 mm/year; p = 0.138), target inclination angle (median difference, 0.013 mm/year; p = 0.354), or neither target (median difference, 0.012 mm/year; p = 0.322). Conclusion Placing the acetabular component within or outside the 'safe zone' did not alter the wear rate of HXLPE at long-term follow-up to a level that risked osteolysis. HXLPE appears to be a forgiving bearing material in terms of articular surface wear, but care must still be taken to position the acetabular component correctly so that the implant is stable. Cite this article: Bone Joint J 2018;100-B:891-7.
Collapse
Affiliation(s)
- M G Teeter
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - B A Lanting
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - D D Naudie
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - R W McCalden
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - J L Howard
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - S J MacDonald
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|