1
|
Han X, Zhang Y, Shi G, Liu G, Ai S, Wang Y, Zhang Q, He X. Quantitative assessment of corneal elasticity distribution after FS-LASIK using optical coherence elastography. JOURNAL OF BIOPHOTONICS 2024; 17:e202300441. [PMID: 38221644 DOI: 10.1002/jbio.202300441] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 12/12/2023] [Accepted: 01/04/2024] [Indexed: 01/16/2024]
Abstract
Quantifying corneal elasticity after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) procedure plays an important role in improving surgical safety and quality, since some latent complications may occur ascribing to changes in postoperative corneal biomechanics. Nevertheless, it is suggested that current research has been severely constrained due to the lack of an accurate quantification method to obtain postoperative corneal elasticity distribution. In this paper, an acoustic radiation force optical coherence elastography system combined with the improved phase velocity algorithm was utilized to realize elasticity distribution images of the in vivo rabbit cornea after FS-LASIK under various intraocular pressure levels. As a result, elasticity variations within and between the regions of interest could be identified precisely. This is the first time that elasticity imaging of in vivo cornea after FS-LASIK surgery was demonstrated, and the results suggested that this technology may hold promise in further exploring corneal biomechanical properties after refractive surgery.
Collapse
Affiliation(s)
- Xiao Han
- School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, P. R. China
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Yubao Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Gang Shi
- School of Mathematics and Physics, University of Science and Technology Beijing, Beijing, China
| | - Guo Liu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Sizhu Ai
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Yidi Wang
- School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, P. R. China
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Qin Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Xingdao He
- School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, P. R. China
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| |
Collapse
|
2
|
Luo J, Zhang Y, Ai S, Shi G, Han X, Wang Y, Zhao Y, Yang H, Li Y, He X. Two-dimensional elastic distribution imaging of the sclera using acoustic radiation force optical coherence elastography. JOURNAL OF BIOPHOTONICS 2024; 17:e202300368. [PMID: 38010344 DOI: 10.1002/jbio.202300368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/23/2023] [Accepted: 11/15/2023] [Indexed: 11/29/2023]
Abstract
The scleral elasticity is closely related with many ocular diseases, but the relevant research is still insufficient. Here, we utilized optical coherence elastography to carefully study biomechanical properties of the sclera at different positions and under different intraocular pressures. Meanwhile, elastic wave velocity and Young's modulus of each position were obtained using a phase velocity algorithm. Accordingly, the two-dimensional elasticity distribution image was achieved by mapping the Young's modulus values to the corresponding structure based on the relationship between the position and its Young's modulus. Therefore, elastic information in regions-of-interest can be read and compared directly from the scleral structure, indicating that our method may be a very useful tool to evaluate the elasticity of sclera and provide intuitive and reliable proof for diagnosis and research.
Collapse
Affiliation(s)
- Jiahui Luo
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| | - Yubao Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| | - Sizhu Ai
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| | - Gang Shi
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| | - Xiao Han
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| | - Yidi Wang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| | - Yanzhi Zhao
- Eye Center, Second Affiliated Hospital of Nanchang University, Nanchang, PR China
| | - Hongwei Yang
- Eye Center, Second Affiliated Hospital of Nanchang University, Nanchang, PR China
| | - Yingjie Li
- Department of Ophthalmology, Nanchang First Hospital, Nanchang, PR China
| | - Xingdao He
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, PR China
| |
Collapse
|
3
|
Zhao Y, Zhu Y, Yan Y, Yang H, Liu J, Lu Y, Li Y, Huang G. In Vivo Evaluation of Corneal Biomechanics Following Cross-Linking Surgeries Using Optical Coherence Elastography in a Rabbit Model of Keratoconus. Transl Vis Sci Technol 2024; 13:15. [PMID: 38376862 PMCID: PMC10883337 DOI: 10.1167/tvst.13.2.15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 12/30/2023] [Indexed: 02/21/2024] Open
Abstract
Purpose Validation of the feasibility of novel acoustic radiation force optical coherence elastography (ARF-OCE) for the evaluation of biomechanical enhancement of the in vivo model of keratoconus by clinical cross-linking (CXL) surgery. Methods Twelve in vivo rabbit corneas were randomly divided into two groups. Both groups were treated with collagenase type II, and a keratoconus model was obtained. Then, the two groups were treated with CXL procedures with different irradiation energy of 15 J and 30 J (CXL-15 J and CXL-30 J, respectively). An ARF-OCE probe with an ultrasmall ultrasound transducer was used to detect the biomechanical properties of cornea. An antisymmetric Lamb wave model was combined with the frequency dispersion relationship to achieve depth-resolved elastography. Results Compared with the phase velocity of the Lamb wave in healthy corneas (approximately 3.96 ± 0.27 m/s), the phase velocity of the Lamb wave was lower in the keratoconus region (P < 0.05), with an average value of 3.12 ± 0.12 m/s. Moreover, the corneal stiffness increased after CXL treatment (P < 0.05), and the average phase velocity of the Lamb wave was 4.3 ± 0.19 m/s and 4.54 ± 0.13 m/s after CXL-15 J and CXL-30 J treatment. Conclusions The Young's moduli of the keratoconus regions were significantly lower than the healthy corneas. Moreover, the Young's modulus of the keratoconus regions was significantly higher after CXL-30 J treatment than after CXL-15 J treatment. We demonstrated that the ARF-OCE technique has great potential in screening keratoconus and guiding clinical CXL treatment. Translational Relevance This work accelerates the clinical translation of OCE systems using ultrasmall ultrasound transducers and is used to guide CXL procedures.
Collapse
Affiliation(s)
- Yanzhi Zhao
- Eye Center, Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China
| | - Yirui Zhu
- School of Physics, University of Nanjing, Nanjing, Jiangsu, China
- School of Testing and Opto-electronic Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, China
| | - Yange Yan
- Yujiang District People's Hospital, Jiangxi, China
| | - Hongwei Yang
- Eye Center, Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China
| | - Jingchao Liu
- Department of Ophthalmology, Nanchang First Hospital, Nanchang, Jiangxi, China
| | - Yongan Lu
- Department of Ophthalmology, Nanchang First Hospital, Nanchang, Jiangxi, China
| | - Yingjie Li
- Department of Ophthalmology, Nanchang First Hospital, Nanchang, Jiangxi, China
| | - Guofu Huang
- Eye Center, Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China
| |
Collapse
|
4
|
Zhu Y, Shi J, Alvarez-arenas TEG, Li C, Wang H, Cai H, Zhang D, He X, Wu X. Supershear Rayleigh wave imaging for quantitative assessment of biomechanical properties of brain using air-coupled optical coherence elastography. APL Bioeng 2023; 7:046107. [PMID: 37915751 PMCID: PMC10618026 DOI: 10.1063/5.0160213] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Accepted: 10/12/2023] [Indexed: 11/03/2023] Open
Abstract
Recently, supershear Rayleigh waves (SRWs) have been proposed to characterize the biomechanical properties of soft tissues. The SRWs propagate along the surface of the medium, unlike surface Rayleigh waves, SRWs propagate faster than bulk shear waves. However, their behavior and application in biological tissues is still elusive. In brain tissue elastography, shear waves combined with magnetic resonance elastography or ultrasound elastography are generally used to quantify the shear modulus, but high spatial resolution elasticity assessment in 10 μm scale is still improving. Here, we develop an air-coupled ultrasonic transducer for noncontact excitation of SRWs and Rayleigh waves in brain tissue, use optical coherent elastography (OCE) to detect, and reconstruct the SRW propagation process; in combing with a derived theoretical model of SRWs on a free boundary surface, we quantify the shear modulus of brain tissue with high spatial resolution. We first complete validation experiments using a homogeneous isotropic agar phantom, and the experimental results clearly show the SRW is 1.9649 times faster than the bulk shear waves. Furthermore, the propagation velocity of SRWs in both the frontal and parietal lobe regions of the brain is all 1.87 times faster than the bulk shear wave velocity. Finally, we evaluated the anisotropy in different brain regions, and the medulla oblongata region had the highest anisotropy index. Our study shows that the OCE system using the SRW model is a new potential approach for high-resolution assessment of the biomechanical properties of brain tissue.
Collapse
Affiliation(s)
| | - Jiulin Shi
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang 330063, China
| | - Tomas E. Gomez Alvarez-arenas
- Ultrasonic and Sensors Technologies Department, Information and Physical Technologies Institute, Spanish National Research Council, Serrano 144, 28006 Madrid, Spain
| | - Chenxi Li
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang 330063, China
| | - Haohao Wang
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang 330063, China
| | - Hongling Cai
- School of Physics, Nanjing University, Nanjing 210093, China
| | - Dong Zhang
- School of Physics, Nanjing University, Nanjing 210093, China
| | - Xingdao He
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang 330063, China
| | - Xiaoshan Wu
- School of Physics, Nanjing University, Nanjing 210093, China
| |
Collapse
|
5
|
Zhu Y, Shi J, Alvarez-Arenas TEG, Li C, Wang H, Zhang D, He X, Wu X. Noncontact longitudinal shear wave imaging for the evaluation of heterogeneous porcine brain biomechanical properties using optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2023; 14:5113-5126. [PMID: 37854580 PMCID: PMC10581781 DOI: 10.1364/boe.497801] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 08/09/2023] [Accepted: 08/09/2023] [Indexed: 10/20/2023]
Abstract
High-resolution quantification of heterogeneous brain biomechanical properties has long been an important topic. Longitudinal shear waves (LSWs) can be used to assess the longitudinal Young's modulus, but contact excitation methods have been used in most previous studies. We propose an air-coupled ultrasound transducer-based optical coherence elastography (AcUT-OCE) technique for noncontact excitation and detection of LSWs in samples and assessment of the nonuniformity of the brain's biomechanical properties. The air-coupled ultrasonic transducer (AcUT) for noncontact excitation of LSWs in the sample has a center frequency of 250 kHz. Phase-resolved Doppler optical coherence tomography (OCT) was used to image and reconstruct the propagation behavior of LSWs and surface ultrasound waves at high resolution. An agar phantom model was used to verify the feasibility of the experimental protocol, and experiments with ex vivo porcine brain samples were used to assess the nonuniformity of the brain biomechanical properties. LSWs with velocities of 0.83 ± 0.11 m/s were successfully excited in the agar phantom model. The perivascular elastography results in the prefrontal cortex (PFC) of the ex vivo porcine brains showed that the Young's modulus was significantly higher in the longitudinal and transverse directions on the left side of the cerebral vessels than on the right side and that the Young's modulus of the PFC decreased with increasing depth. The AcUT-OCE technique, as a new scheme for LSW applications in in vivo elastography, can be used for noncontact excitation of LSWs in brain tissue and high-resolution detection of heterogeneous brain biomechanical properties.
Collapse
Affiliation(s)
- Yirui Zhu
- School of Physics, Nanjing University, Nanjing, 210093, China
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang, 330063, China
| | - Jiulin Shi
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang, 330063, China
| | - Tomas E Gomez Alvarez-Arenas
- Ultrasonic and Sensors Technologies Department, Information and Physical Technologies Institute, Spanish National Research Council, Serrano 144, 28006, Madrid, Spain
| | - Chenxi Li
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang, 330063, China
| | - Haohao Wang
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang, 330063, China
| | - Dong Zhang
- School of Physics, Nanjing University, Nanjing, 210093, China
| | - Xingdao He
- School of Testing and Opto-electric Engineering, Nanchang Hangkong University, Nanchang, 330063, China
| | - Xiao Wu
- School of Physics, Nanjing University, Nanjing, 210093, China
| |
Collapse
|
6
|
Ai S, Zhang Y, Shi G, Wang Y, Liu G, Han X, Zhao Y, Yang H, He X. Acoustic radiation force optical coherence elastography: A preliminary study on biomechanical properties of trabecular meshwork. JOURNAL OF BIOPHOTONICS 2023; 16:e202200317. [PMID: 36602423 DOI: 10.1002/jbio.202200317] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/11/2022] [Accepted: 12/28/2022] [Indexed: 05/17/2023]
Abstract
Evaluating biomechanical properties of trabecular meshwork (TM) is of great significance for understanding the mechanism of aqueous humor circulation and its relationship to some eye diseases such as glaucoma; however, there is almost no relevant study due to the lack of clinical measurement tool. In this paper, an acoustic radiation force optical coherence elastography (ARF-OCE) system is developed with the advantages of noninvasive detection, high resolution, high sensitivity, and high-speed imaging, by which elastic modulus of the porcine and human TMs is accurately quantified. As the first OCE imaging of TM, our study demonstrates that ARF-OCE may be an effective approach to advance the research of diseases related to aqueous humor circulation.
Collapse
Affiliation(s)
- Sizhu Ai
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| | - Yubao Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| | - Gang Shi
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| | - Yidi Wang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| | - Guo Liu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| | - Xiao Han
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| | | | | | - Xingdao He
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, China
| |
Collapse
|
7
|
Zhu Y, Zhao Y, Shi J, Gomez Alvarez-Arenas TE, Yang H, Cai H, Zhang D, He X, Wu X. Novel acoustic radiation force optical coherence elastography based on ultrasmall ultrasound transducer for biomechanics evaluation of in vivo cornea. JOURNAL OF BIOPHOTONICS 2023:e202300074. [PMID: 37101410 DOI: 10.1002/jbio.202300074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/09/2023] [Accepted: 04/25/2023] [Indexed: 05/23/2023]
Abstract
We developed a novel acoustic radiation force optical coherence elastography (ARF-OCE) based on an ultrasmall ultrasound transducer for quantitative biomechanics evaluations of in vivo cornea. A custom single-sided meta-ultrasonic transducer with an outer diameter of 1.8 mm, focal spot diameter of 1.6 mm, central frequency of 930 kHz, and focal length of 0.8 mm was applied to excite the sample. The sample arm of the ARF-OCE system employed a three-dimensional printed holder that allowed for ultrasound excitation and ARF-OCE detection. The phase-resolved algorithm was combined with a Lamb wave model to depth-resolved evaluate corneal biomechanics after keratoconus and cross-linking treatments (CXL). The results showed that, compare to the healthy cornea, the Lamb wave velocity was significantly reduced in the keratoconus, increased in the cornea after CXL, and increased with cross-linked irradiation energy in the cornea. These results indicated the good clinical translation potential of the proposed novel ARF-OCE.
Collapse
Affiliation(s)
- Yirui Zhu
- School of Physics, Nanjing University, Nanjing, China
- School of Testing and Opto-Electric Engineering, Nanchang Hangkong University, Nanchang, China
| | - Yanzhi Zhao
- School of Medicine, Nanchang University, Nanchang, China
| | - Jiulin Shi
- School of Testing and Opto-Electric Engineering, Nanchang Hangkong University, Nanchang, China
| | - Tomas E Gomez Alvarez-Arenas
- Ultrasonic and Sensors Technologies Department, Information and Physical Technologies Institute, Spanish National Research Council, Madrid, Spain
| | - Hongwei Yang
- School of Medicine, Nanchang University, Nanchang, China
| | - Hongling Cai
- School of Physics, Nanjing University, Nanjing, China
| | - Dong Zhang
- School of Physics, Nanjing University, Nanjing, China
| | - Xingdao He
- School of Testing and Opto-Electric Engineering, Nanchang Hangkong University, Nanchang, China
| | - Xiaoshan Wu
- School of Physics, Nanjing University, Nanjing, China
| |
Collapse
|
8
|
Zhao Y, Yang H, Li Y, Wang Y, Han X, Zhu Y, Zhang Y, Huang G. Quantitative Assessment of Biomechanical Properties of the Human Keratoconus Cornea Using Acoustic Radiation Force Optical Coherence Elastography. Transl Vis Sci Technol 2022; 11:4. [PMID: 35666497 PMCID: PMC9185997 DOI: 10.1167/tvst.11.6.4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Quantification of biomechanical properties of keratoconus (KC) corneas has great significance for early diagnosis and treatment of KC, but the corresponding clinical measurement remains challenging. Here, we developed an acoustic radiation force (ARF) optical coherence elastography technique and explored its potential for evaluating biomechanical properties of KC corneas. Methods An ARF system was used to induce the tissue deformation, which was detected by an optical coherence tomography system, and thus the localized point-by-point Young's modulus measurements were achieved. Then, two healthy rabbit eyes were imaged to test the system, after which the human keratoconus cornea was evaluated by using the same method. Three regions were selected for biomechanics analysis: the conical region, the transitional region, and the peripheral region. Results Young's moduli of transitional region ranged from 53.3 to 58.5 kPa. The corresponding values for the peripheral region were determined to be 58.6 kPa and 63.2 kPa, respectively. Young's moduli of the conical region were gradually increased by 18.3% from the center to the periphery, resulting in the minimum and maximum values of 44.9 kPa and 53.1 kPa, respectively. Furthermore, Young's moduli of the anterior and posterior of the center were determined to be 44.9 kPa and 50.7 kPa, respectively. Conclusions Differences in biomechanical properties between the three regions and slight variations within the conical region were clearly distinguished. Biomechanical weakening of the keratoconus cornea was mainly localized in the conical region, especially in the vertex position. Translational Relevance The system may provide a promising clinical tool for the noninvasive evaluation of local corneal biomechanics and thus may have potential applications in early keratoconus detection with further optimization.
Collapse
Affiliation(s)
- Yanzhi Zhao
- Nanchang University, Nanchang, P. R. China.,Department of Ophthalmology, The Third Affiliated Hospital of Nanchang University, Nanchang, P. R. China
| | - Hongwei Yang
- Nanchang University, Nanchang, P. R. China.,Department of Ophthalmology, The Third Affiliated Hospital of Nanchang University, Nanchang, P. R. China
| | - Yingjie Li
- Nanchang University, Nanchang, P. R. China.,Department of Ophthalmology, The Third Affiliated Hospital of Nanchang University, Nanchang, P. R. China
| | - Yongbo Wang
- Nanchang University, Nanchang, P. R. China.,Department of Ophthalmology, The Third Affiliated Hospital of Nanchang University, Nanchang, P. R. China
| | - Xiao Han
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Yirui Zhu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Yubao Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang, P. R. China
| | - Guofu Huang
- Nanchang University, Nanchang, P. R. China.,Department of Ophthalmology, The Third Affiliated Hospital of Nanchang University, Nanchang, P. R. China
| |
Collapse
|
9
|
Abstract
PURPOSE OF REVIEW Biomechanics is an important aspect of the complex family of diseases known as the glaucomas. Here, we review recent studies of biomechanics in glaucoma. RECENT FINDINGS Several tissues have direct and/or indirect biomechanical roles in various forms of glaucoma, including the trabecular meshwork, cornea, peripapillary sclera, optic nerve head/sheath, and iris. Multiple mechanosensory mechanisms and signaling pathways continue to be identified in both the trabecular meshwork and optic nerve head. Further, the recent literature describes a variety of approaches for investigating the role of tissue biomechanics as a risk factor for glaucoma, including pathological stiffening of the trabecular meshwork, peripapillary scleral structural changes, and remodeling of the optic nerve head. Finally, there have been advances in incorporating biomechanical information in glaucoma prognoses, including corneal biomechanical parameters and iridial mechanical properties in angle-closure glaucoma. SUMMARY Biomechanics remains an active aspect of glaucoma research, with activity in both basic science and clinical translation. However, the role of biomechanics in glaucoma remains incompletely understood. Therefore, further studies are indicated to identify novel therapeutic approaches that leverage biomechanics. Importantly, clinical translation of appropriate assays of tissue biomechanical properties in glaucoma is also needed.
Collapse
Affiliation(s)
- Babak N. Safa
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA
| | - Cydney A. Wong
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA
| | - Jungmin Ha
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA
| | - C. Ross Ethier
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta GA, USA
| |
Collapse
|
10
|
Han X, Zhang Y, Zhu Y, Zhao Y, Yang H, Liu G, Ai S, Wang Y, Xie C, Shi J, Zhang T, Huang G, He X. Quantification of biomechanical properties of human corneal scar using acoustic radiation force optical coherence elastography. Exp Biol Med (Maywood) 2021; 247:462-469. [PMID: 34861122 PMCID: PMC8943333 DOI: 10.1177/15353702211061881] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Biomechanical properties of corneal scar are strongly correlated with many corneal diseases and some types of corneal surgery, however, there is no elasticity information available about corneal scar to date. Here, we proposed an acoustic radiation force optical coherence elastography system to evaluate corneal scar elasticity. Elasticity quantification was first conducted on ex vivo rabbit corneas, and the results validate the efficacy of our system. Then, experiments were performed on an ex vivo human scarred cornea, where the structural features, the elastic wave propagations, and the corresponding Young's modulus of both the scarred region and the normal region were achieved and based on this, 2D spatial distribution of Young's modulus of the scarred cornea was depicted. Up to our knowledge, we realized the first elasticity quantification of corneal scar, which may provide a potent tool to promote clinical research on the disorders and surgery of the cornea.
Collapse
Affiliation(s)
- Xiao Han
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yubao Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yirui Zhu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yanzhi Zhao
- The Third Affiliated Hospital of Nanchang University, Nanchang 330008, P. R. China
| | - Hongwei Yang
- The Third Affiliated Hospital of Nanchang University, Nanchang 330008, P. R. China
| | - Guo Liu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Sizhu Ai
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yidi Wang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Chengfeng Xie
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Jiulin Shi
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Tianyu Zhang
- Key Laboratory of Geophysical Exploration Equipment, Ministry of Education, College of Instrumentation & Electrical Engineering, 12510Jilin University, Changchun 130012, P. R. China
| | - Guofu Huang
- The Third Affiliated Hospital of Nanchang University, Nanchang 330008, P. R. China
| | - Xingdao He
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| |
Collapse
|
11
|
Ye S, Zhou Y, Bao C, Chen Y, Lu F, Zhu D. In vivo non-contact measurement of human iris elasticity by optical coherence elastography. JOURNAL OF BIOPHOTONICS 2021; 14:e202100116. [PMID: 34051066 DOI: 10.1002/jbio.202100116] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/22/2021] [Accepted: 05/25/2021] [Indexed: 06/12/2023]
Abstract
Quantifying the mechanical properties of the iris can offer valuable insights into the pathophysiology of primary angle closure glaucoma. However, current techniques for iris elastography remain ex vivo with limited clinical applications. This article describes a proposition for a non-contact and non-invasive air-puff optical coherence elastography (OCE) system that can evaluate iris elasticity in vivo. Ten eyes recruited from seven subjects underwent OCE imaging acquisition under three different illumination conditions. The Young's modulus of each eye was detected and shown to be inversely proportional to the iris length, indicating a relationship between mechanical properties and morphology of the iris. With its noninvasive and high-resolution features, this air-puff system shows great potential for applications in clinical ophthalmology.
Collapse
Affiliation(s)
- Shuling Ye
- School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, China
| | - Yuheng Zhou
- School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, China
| | - Chenhong Bao
- School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, China
| | - Yulei Chen
- School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, China
| | - Fan Lu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, China
| | - Dexi Zhu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, China
| |
Collapse
|