1
|
Parakkel RR, Wong D, Li C, Cheong J, Nongpiur ME, Chong RS, Aung T, Schmetterer L, Liu X, Chua J. Retinal Nerve Fiber Layer Damage Assessment in Glaucomatous Eyes Using Retinal Retardance Measured by Polarization-Sensitive Optical Coherence Tomography. Transl Vis Sci Technol 2024; 13:9. [PMID: 38743409 PMCID: PMC11103739 DOI: 10.1167/tvst.13.5.9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 03/20/2024] [Indexed: 05/16/2024] Open
Abstract
Purpose To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.
Collapse
Affiliation(s)
| | - Damon Wong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) Program, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Chi Li
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) Program, Singapore, Singapore
| | - Jocelyn Cheong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Monisha Esther Nongpiur
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Rachel Shujuan Chong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Tin Aung
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Leopold Schmetterer
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) Program, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - Xinyu Liu
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) Program, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) Program, Singapore, Singapore
- Ophthalmology & Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| |
Collapse
|
2
|
Chen G, Wang W, Li Y. Reducing noise in polarization-sensitive optical coherence tomography for high-quality local phase retardation imaging. APPLIED OPTICS 2024; 63:2822-2830. [PMID: 38856377 DOI: 10.1364/ao.515942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 03/17/2024] [Indexed: 06/11/2024]
Abstract
Local phase retardation (LPR) is increasingly recognized as a crucial biomarker for assessing disease progression. However, the presence of speckle noise significantly challenges its accuracy and polarization contrast. To address this challenge, we propose a signal-processing strategy aimed at reducing the impact of noise on LPR measurements. In this approach, the LPR is reconstructed by polar decomposition after averaging multiple Mueller matrices from different overlapping sub-spectra. To optimize measurement accuracy, we systematically combined and traversed different sub-spectral numbers and bandwidths. By examining the quarter-wave plate and glass slide, high-accuracy phase retardation measurements were successfully verified, and the maximum polarization contrast was improved by 23%. Moreover, experimental results from multi-tissue imaging vividly illustrate that the equivalent number of looks (ENL) and polarization contrast were improved by 18% and 19%, respectively. This outcome indicates that our proposed strategy can effectively reduce the noise spikes, enhancing tissue discrimination capabilities.
Collapse
|
3
|
Wang C, Liu Y, Calle P, Li X, Liu R, Zhang Q, Yan F, Fung KM, Conner AK, Chen S, Pan C, Tang Q. Enhancing epidural needle guidance using a polarization-sensitive optical coherence tomography probe with convolutional neural networks. JOURNAL OF BIOPHOTONICS 2024; 17:e202300330. [PMID: 37833242 PMCID: PMC10922538 DOI: 10.1002/jbio.202300330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 09/28/2023] [Accepted: 10/10/2023] [Indexed: 10/15/2023]
Abstract
Epidural anesthesia helps manage pain during different surgeries. Nonetheless, the precise placement of the epidural needle remains a challenge. In this study, we developed a probe based on polarization-sensitive optical coherence tomography (PS-OCT) to enhance the epidural anesthesia needle placement. The probe was tested on six porcine spinal samples. The multimodal imaging guidance used the OCT intensity mode and three distinct PS-OCT modes: (1) phase retardation, (2) optic axis, and (3) degree of polarization uniformity (DOPU). Each mode enabled the classification of different epidural tissues through distinct imaging characteristics. To further streamline the tissue recognition procedure, convolutional neural network (CNN) were used to autonomously identify the tissue types within the probe's field of view. ResNet50 models were developed for all four imaging modes. DOPU imaging was found to provide the highest cross-testing accuracy of 91.53%. These results showed the improved precision by PS-OCT in guiding epidural anesthesia needle placement.
Collapse
Affiliation(s)
- Chen Wang
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Yunlong Liu
- School of Computer Science, University of Oklahoma, Norman, OK 73019, USA
| | - Paul Calle
- School of Computer Science, University of Oklahoma, Norman, OK 73019, USA
| | - Xinwei Li
- Department of Electrical and Electronic Engineering, University of Nottingham, Nottingham, United Kingdom, NG7 2RD
| | - Ronghao Liu
- School of Computer Science and Technology, Shandong Jianzhu University, Jinan, 250100, China
| | - Qinghao Zhang
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Feng Yan
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Kar-ming Fung
- Department of Pathology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
- Stephenson Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Andrew K. Conner
- Department of Neurosurgery, University of Oklahoma College of Medicine, Oklahoma City, OK 73104, USA
| | - Sixia Chen
- Department of Biostatistics and Epidemiology, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Chongle Pan
- School of Computer Science, University of Oklahoma, Norman, OK 73019, USA
| | - Qinggong Tang
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| |
Collapse
|
4
|
Yan F, Wang C, Yan Y, Zhang Q, Yu Z, Patel SG, Fung KM, Tang Q. Polarization-sensitive optical coherence tomography for renal tumor detection in ex vivo human kidneys. OPTICS AND LASERS IN ENGINEERING 2024; 173:107900. [PMID: 37982078 PMCID: PMC10653339 DOI: 10.1016/j.optlaseng.2023.107900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
Kidney cancer is a kind of high mortality cancer because of the difficulty in early diagnosis and the high metastatic dissemination in treatments. The surgical resection of tumors is the most effective treatment for renal cancer patients. However, precise assessment of tumor margins is a challenge during surgical resection. The objective of this study is to demonstrate an optical imaging tool in precisely distinguishing kidney tumor borders and identifying tumor zones from normal tissues to assist surgeons in accurately resecting tumors from kidneys during the surgery. 30 samples from six human kidneys were imaged using polarization-sensitive optical coherence tomography (PS-OCT). Cross-sectional, enface, and spatial information of kidney samples were obtained for microenvironment reconstruction. Polarization parameters (phase retardation, optic axis direction, and degree of polarization uniformity (DOPU) and Stokes parameters (Q, U, and V) were utilized for multi-parameter analysis. To verify the detection accuracy of PS-OCT, H&E histology staining and dice-coefficient was utilized to quantify the performance of PS-OCT in identifying tumor borders and regions. In this study, tumor borders were clearly identified by PS-OCT imaging, which outperformed the conventional intensity-based OCT. With H&E histological staining as golden standard, PS-OCT precisely identified the tumor regions and tissue distributions at different locations and different depths based on polarization and Stokes parameters. Compared to the traditional attenuation coefficient quantification method, PS-OCT demonstrated enhanced contrast of tissue characteristics between normal and cancerous tissues due to the birefringence effects. Our results demonstrated that PS-OCT was promising to provide imaging guidance for the surgical resection of kidney tumors and had the potential to be used for other human kidney surgeries in clinics such as renal biopsy.
Collapse
Affiliation(s)
- Feng Yan
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Chen Wang
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Yuyang Yan
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Qinghao Zhang
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Zhongxin Yu
- Department of Pathology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Sanjay G. Patel
- Department of Urology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Kar-Ming Fung
- Department of Pathology, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
- Stephenson Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Qinggong Tang
- Stephenson School of Biomedical Engineering, University of Oklahoma, Norman, OK 73019, USA
- Institute for Biomedical Engineering, Science, and Technology (IBEST), University of Oklahoma, Norman, OK 73019, USA
| |
Collapse
|
5
|
Liu X, Jiang L, Ke M, Sigal IA, Chua J, Hoang QV, Chia AW, Najjar RP, Tan B, Cheong J, Bellemo V, Chong RS, Girard MJA, Ang M, Liu M, Garhöfer G, Barathi VA, Saw SM, Villiger M, Schmetterer L. Posterior scleral birefringence measured by triple-input polarization-sensitive imaging as a biomarker of myopia progression. Nat Biomed Eng 2023; 7:986-1000. [PMID: 37365268 PMCID: PMC10427432 DOI: 10.1038/s41551-023-01062-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 05/30/2023] [Indexed: 06/28/2023]
Abstract
In myopic eyes, pathological remodelling of collagen in the posterior sclera has mostly been observed ex vivo. Here we report the development of triple-input polarization-sensitive optical coherence tomography (OCT) for measuring posterior scleral birefringence. In guinea pigs and humans, the technique offers superior imaging sensitivities and accuracies than dual-input polarization-sensitive OCT. In 8-week-long studies with young guinea pigs, scleral birefringence was positively correlated with spherical equivalent refractive errors and predicted the onset of myopia. In a cross-sectional study involving adult individuals, scleral birefringence was associated with myopia status and negatively correlated with refractive errors. Triple-input polarization-sensitive OCT may help establish posterior scleral birefringence as a non-invasive biomarker for assessing the progression of myopia.
Collapse
Affiliation(s)
- Xinyu Liu
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) programme, Singapore, Singapore
| | - Liqin Jiang
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
| | - Mengyuan Ke
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Ian A Sigal
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Jacqueline Chua
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) programme, Singapore, Singapore
| | - Quan V Hoang
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine National University of Singapore, Singapore, Singapore
- Department of Ophthalmology, Columbia University, New York, NY, USA
| | - Audrey Wi Chia
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
| | - Raymond P Najjar
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine National University of Singapore, Singapore, Singapore
| | - Bingyao Tan
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- SERI-NTU Advanced Ocular Engineering (STANCE) programme, Singapore, Singapore
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore
| | - Jocelyn Cheong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
| | - Valentina Bellemo
- SERI-NTU Advanced Ocular Engineering (STANCE) programme, Singapore, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
| | - Rachel S Chong
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
| | - Michaël J A Girard
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland
| | - Marcus Ang
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
| | - Mengyang Liu
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Gerhard Garhöfer
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Veluchamy A Barathi
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine National University of Singapore, Singapore, Singapore
- Translational Pre-Clinical Model Platform, Singapore Eye Research Institute, Singapore, Singapore
| | - Seang-Mei Saw
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore
- Saw Swee Hock School of Public Health, ,National University of Singapore, National University Health System, Singapore, Singapore
| | - Martin Villiger
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
| | - Leopold Schmetterer
- Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
- Academic Clinical Program, Duke-NUS Medical School, Singapore, Singapore.
- SERI-NTU Advanced Ocular Engineering (STANCE) programme, Singapore, Singapore.
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, Singapore, Singapore.
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore.
- Institute of Molecular and Clinical Ophthalmology, Basel, Switzerland.
- Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
6
|
Sharma V, Sinha A. Electrically controlled dual-mode polarization beam splitter using a nematic liquid crystal. OPTICS LETTERS 2023; 48:2357-2360. [PMID: 37126273 DOI: 10.1364/ol.484857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Polarization handling using an external source is highly desirable in applied optics and photonics to increase the degree of freedom of an optical system. Here we report an electrically controlled polarization beam splitter (PBS) by sandwiching the nematic liquid crystal (LC) between two equilateral prisms. The presented LC-PBS is operated in two different modes: non-splitting mode and polarization splitting mode. The externally applied voltage can switch the mode of the PBS, which makes the device active and flexible. The proposed electrically controlled PBS exhibits features such as bistability with highly stable modes, large splitting angle, wider operating range, and ease of fabrication with lower cost.
Collapse
|
7
|
Wu T, Zou J, Liu Y, Lu Y, Wang J, Shi Y, Shen H, Gu X, He C. Local polarization properties extraction using single incident state, single-mode-fiber-based spectral domain polarization-sensitive optical coherence tomography. APPLIED OPTICS 2023; 62:989-996. [PMID: 36821157 DOI: 10.1364/ao.476231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 01/01/2023] [Indexed: 06/18/2023]
Abstract
We showed the local polarization properties extraction method for the single incident state, all-single-mode-fiber-based spectral domain polarization-sensitive optical coherence tomography (SD-PS-OCT) system that uses the single linear-in-wavenumber spectral camera. Polarization controllers are used in the single-mode-fiber-based SD-PS-OCT system to provide a compact structure with polarization state stability. The local polarization properties of the birefringent sample are extracted from the cumulative polarization properties iteratively. The reconstructed polarization images demonstrate the local polarization properties extraction ability of the system.
Collapse
|
8
|
Cense B, Maddipatla R, Cervantes Lozano FJ, Joo C. Two concepts for ultra-high-resolution polarization-sensitive optical coherence tomography with a single camera. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2022; 39:1295-1308. [PMID: 36215616 DOI: 10.1364/josaa.458631] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 06/12/2022] [Indexed: 06/16/2023]
Abstract
Two designs with a multiplexed superluminescent diode for ultra-high-resolution spectral-domain polarization-sensitive optical coherence tomography (UHR-PS-OCT) are introduced. In the first design, a Wollaston prism separates orthogonal polarization states next to each other on one linescan camera; the other design uses a beam displacer to separate orthogonal states onto two lines of a linescan camera with multiple rows of detectors. The coherence lengths measured with the two systems were 3.6 µm and 2.9 µm (n=1.38), respectively. Measurements were collected from the fovea of a healthy subject, a healthy subject with astigmatism, and a patient with central serous retinopathy (CSR). A single volumetric scan provides double pass retardance induced by the retinal nerve fiber layer birefringence (RNFL) and its birefringence, the cumulative double pass retardance induced by the Henle fiber layer, and the retardance that is induced by the retinal pigment epithelium-Bruch's membrane complex. The high axial resolution in UHR-PS-OCT is particularly helpful for the measurements of thin retinal tissue, such as the RNFL in the fovea, where birefringence values of around 1°/µm were found. Tilting of the retina due to a CSR or by off centering the imaging beam in the pupil causes an artificial increase in the double pass retardance induced by the RNFL and Henle fiber layer.
Collapse
|
9
|
Adams DC, Majid A, Suter MJ. Polarization mode dispersion correction in endoscopic polarization-sensitive optical coherence tomography with incoherent polarization input states. BIOMEDICAL OPTICS EXPRESS 2022; 13:3446-3460. [PMID: 35781955 PMCID: PMC9208610 DOI: 10.1364/boe.457790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 04/09/2022] [Accepted: 04/21/2022] [Indexed: 05/11/2023]
Abstract
The incorporation of polarization sensitivity into optical coherence tomography (PS-OCT) imaging can greatly enhance utility by allowing differentiation via intrinsic contrast of many types of tissue. In fiber-based OCT systems such as those employing endoscopic imaging probes, however, polarization mode dispersion (PMD) can significantly impact the ability to obtain accurate polarization data unless valuable axial resolution is sacrificed. In this work we present a new technique for compensating for PMD in endoscopic PS-OCT with minimal impact on axial resolution and without requiring mutually coherent polarization inputs, needing only a birefringent structure with known orientation in view (such as the catheter sheath). We then demonstrate the advantages of this technique by comparing it against the current state of the art approach.
Collapse
Affiliation(s)
- David C. Adams
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Adnan Majid
- Division of Thoracic Surgery and Interventional Pulmonology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02114, USA
| | - Melissa J. Suter
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
10
|
Seesan T, Abd El-Sadek I, Mukherjee P, Zhu L, Oikawa K, Miyazawa A, Shen LTW, Matsusaka S, Buranasiri P, Makita S, Yasuno Y. Deep convolutional neural network-based scatterer density and resolution estimators in optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2022; 13:168-183. [PMID: 35154862 PMCID: PMC8803045 DOI: 10.1364/boe.443343] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 11/03/2021] [Accepted: 11/25/2021] [Indexed: 05/02/2023]
Abstract
We present deep convolutional neural network (DCNN)-based estimators of the tissue scatterer density (SD), lateral and axial resolutions, signal-to-noise ratio (SNR), and effective number of scatterers (ENS, the number of scatterers within a resolution volume). The estimators analyze the speckle pattern of an optical coherence tomography (OCT) image in estimating these parameters. The DCNN is trained by a large number (1,280,000) of image patches that are fully numerically generated in OCT imaging simulation. Numerical and experimental validations were performed. The numerical validation shows good estimation accuracy as the root mean square errors were 0.23%, 3.65%, 3.58%, 3.79%, and 6.15% for SD, lateral and axial resolutions, SNR, and ENS, respectively. The experimental validation using scattering phantoms (Intralipid emulsion) shows reasonable estimations. Namely, the estimated SDs were proportional to the Intralipid concentrations, and the average estimation errors of lateral and axial resolutions were 1.36% and 0.68%, respectively. The scatterer density estimator was also applied to an in vitro tumor cell spheroid, and a reduction in the scatterer density during cell necrosis was found.
Collapse
Affiliation(s)
- Thitiya Seesan
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
- Department of Physics, School of Science, King Mongkut’s Institute of Technology Ladkrabang, Ladkrabang, Bangkok, Thailand
| | - Ibrahim Abd El-Sadek
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
- Department of Physics, Faculty of Science, Damietta University, New Damietta City, Damietta, Egypt
| | - Pradipta Mukherjee
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Lida Zhu
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Kensuke Oikawa
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Arata Miyazawa
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
- Sky Technology Inc., Tsukuba, Ibaraki, Japan
| | - Larina Tzu-Wei Shen
- Clinical Research and Regional Innovation, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | - Satoshi Matsusaka
- Clinical Research and Regional Innovation, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | - Prathan Buranasiri
- Department of Physics, School of Science, King Mongkut’s Institute of Technology Ladkrabang, Ladkrabang, Bangkok, Thailand
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan
| |
Collapse
|
11
|
Bouma B, de Boer J, Huang D, Jang I, Yonetsu T, Leggett C, Leitgeb R, Sampson D, Suter M, Vakoc B, Villiger M, Wojtkowski M. Optical coherence tomography. NATURE REVIEWS. METHODS PRIMERS 2022; 2:79. [PMID: 36751306 PMCID: PMC9901537 DOI: 10.1038/s43586-022-00162-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
Optical coherence tomography (OCT) is a non-contact method for imaging the topological and internal microstructure of samples in three dimensions. OCT can be configured as a conventional microscope, as an ophthalmic scanner, or using endoscopes and small diameter catheters for accessing internal biological organs. In this Primer, we describe the principles underpinning the different instrument configurations that are tailored to distinct imaging applications and explain the origin of signal, based on light scattering and propagation. Although OCT has been used for imaging inanimate objects, we focus our discussion on biological and medical imaging. We examine the signal processing methods and algorithms that make OCT exquisitely sensitive to reflections as weak as just a few photons and that reveal functional information in addition to structure. Image processing, display and interpretation, which are all critical for effective biomedical imaging, are discussed in the context of specific applications. Finally, we consider image artifacts and limitations that commonly arise and reflect on future advances and opportunities.
Collapse
Affiliation(s)
- B.E. Bouma
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA,Institute for Medical Engineering and Physics, Massachusetts Institute of Technology, Cambridge, MA, USA,Harvard Medical School, Boston, MA, USA,Corresponding author:
| | - J.F. de Boer
- Department of Physics and Astronomy, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - D. Huang
- Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA
| | - I.K. Jang
- Harvard Medical School, Boston, MA, USA,Cardiology Division, Massachusetts General Hospital, Boston, MA, USA
| | - T. Yonetsu
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - C.L. Leggett
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | - R. Leitgeb
- Institute of Medical Physics, University of Vienna, Wien, Austria
| | - D.D. Sampson
- School of Physics and School of Biosciences and Medicine, University of Surrey, Guildford, United Kingdom
| | - M. Suter
- Harvard Medical School, Boston, MA, USA,Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA
| | - B. Vakoc
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA,Harvard Medical School, Boston, MA, USA
| | - M. Villiger
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA,Harvard Medical School, Boston, MA, USA
| | - M. Wojtkowski
- Institute of Physical Chemistry and International Center for Translational Eye Research, Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland,Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Torun, Poland
| |
Collapse
|
12
|
Liu X, Jiang L, Ke M, Schmetterer L, Barathi VA. Using image data to numerically correct the jitter in polarization depth encoding PS-OCT. OPTICS LETTERS 2021; 46:1692-1695. [PMID: 33793520 DOI: 10.1364/ol.420029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Accepted: 03/06/2021] [Indexed: 06/12/2023]
Abstract
In swept source polarization depth encoding polarization sensitive optical coherence tomography (PS-OCT), the laser jitter induces additional noise to the polarization sensitive measurement. In this Letter, we developed a numerical algorithm to correct the jitter phases based on the image data using the Mueller matrix calculus. The algorithm was demonstrated on in vivo retina imaging of a guinea pig with a custom-built PS-OCT system. The performance of the proposed algorithm was almost comparable to the conventional method of using a physical calibration signal. By not requiring a hardware generated calibration signal and k-clock, the proposed algorithm is useful to reduce the complexity and the cost of a polarization depth encoding PS-OCT system.
Collapse
|
13
|
Willemse J, Gräfe MGO, Verbraak FD, de Boer JF. In Vivo 3D Determination of Peripapillary Scleral and Retinal Layer Architecture Using Polarization-Sensitive Optical Coherence Tomography. Transl Vis Sci Technol 2020; 9:21. [PMID: 33150047 PMCID: PMC7585391 DOI: 10.1167/tvst.9.11.21] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 08/25/2020] [Indexed: 12/24/2022] Open
Abstract
Purpose The purpose of this paper was to determine the architecture of the collagen fibers of the peripapillary sclera, the retinal nerve fiber layer (RNFL), and Henle's fiber layer in vivo in 3D using polarization-sensitive optical coherence tomography (PS-OCT). Methods Seven healthy volunteers were imaged with our in-house built PS-OCT system. PS-OCT imaging included intensity, local phase retardation, relative optic axis, and optic axis uniformity (OAxU). Differential Mueller matrix calculus was used for the first time in ocular tissues to visualize local orientations that varied with depth, incorporating a correction method for the fiber orientation in preceding layers. Results Scleral collagen fiber orientation images clearly showed an inner layer with an orientation parallel to the RNFL orientation, and a deeper layer where the collagen was circularly oriented. RNFL orientation images visualized the nerve fibers leaving the optic nerve head (ONH) in a radial pattern. The phase retardation and orientation of Henle's fiber layer were visualized locally for the first time. Conclusions PS-OCT successfully showed the orientation of the retinal nerve fibers, sclera, and Henle's fiber layer, and is to the extent of our knowledge the only technique able to do so in 3D in vivo. Translational Relevance In vivo 3D imaging of scleral collagen architecture and the retinal neural fibrous structures can improve our understanding of retinal biomechanics and structural alterations in different disease stages of myopia and glaucoma.
Collapse
Affiliation(s)
- Joy Willemse
- Department of Physics and Astronomy, LaserLab Amsterdam, Vrije Universiteit de Boelelaan, Amsterdam, The Netherlands
| | - Maximilian G O Gräfe
- Department of Physics and Astronomy, LaserLab Amsterdam, Vrije Universiteit de Boelelaan, Amsterdam, The Netherlands.,Current address: Imedos Systems GmbH, Am Nasstal 4, Jena, Germany
| | - Frank D Verbraak
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Ophthalmology Department, de Boelelaan, Amsterdam, The Netherlands
| | - Johannes F de Boer
- Department of Physics and Astronomy, LaserLab Amsterdam, Vrije Universiteit de Boelelaan, Amsterdam, The Netherlands.,Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Ophthalmology Department, de Boelelaan, Amsterdam, The Netherlands
| |
Collapse
|
14
|
Haindl R, Duelk M, Gloor S, Dahdah J, Ojeda J, Sturtzel C, Deng S, Joyce Deloria A, Li Q, Liu M, Distel M, Drexler W, Leitgeb R. Ultra-high-resolution SD-OCM imaging with a compact polarization-aligned 840 nm broadband combined-SLED source. BIOMEDICAL OPTICS EXPRESS 2020; 11:3395-3406. [PMID: 32637262 PMCID: PMC7316001 DOI: 10.1364/boe.394229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 05/12/2020] [Accepted: 05/16/2020] [Indexed: 05/15/2023]
Abstract
We analyze the influence of intrinsic polarization alignment on image quality and axial resolution employing a broadband 840 nm light source with an optical bandwidth of 160 nm and an output power of 12 mW tailored for spectral-domain optical coherence microscopy (SD-OCM) applications. Three superluminescent diodes (SLEDs) are integrated into a 14-pin butterfly module using a free-space micro-optical bench architecture, maintaining a constant polarization state across the full spectral output. We demonstrate superior imaging performance in comparison to traditionally coupled-SLED broadband light sources in a teleost model organism in-vivo.
Collapse
Affiliation(s)
- Richard Haindl
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Marcus Duelk
- EXALOS AG, Wagistrasse 21, 8952 Schlieren, Switzerland
| | - Stefan Gloor
- EXALOS AG, Wagistrasse 21, 8952 Schlieren, Switzerland
| | - Jean Dahdah
- EXALOS AG, Wagistrasse 21, 8952 Schlieren, Switzerland
| | - Jose Ojeda
- EXALOS AG, Wagistrasse 21, 8952 Schlieren, Switzerland
| | - Caterina Sturtzel
- Innovative Cancer Models, Children’s Cancer Research Institute, Vienna, Austria
| | - Shiyu Deng
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Abigail Joyce Deloria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Qian Li
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Mengyang Liu
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Martin Distel
- Innovative Cancer Models, Children’s Cancer Research Institute, Vienna, Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Rainer Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory OPTRAMED, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
15
|
Gräfe MGO, van de Kreeke JA, Willemse J, Braaf B, de Jong Y, Tan HS, Verbraak FD, de Boer JF. Subretinal Fibrosis Detection Using Polarization Sensitive Optical Coherence Tomography. Transl Vis Sci Technol 2020; 9:13. [PMID: 32818100 PMCID: PMC7396173 DOI: 10.1167/tvst.9.4.13] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Accepted: 12/16/2019] [Indexed: 12/22/2022] Open
Abstract
Purpose Subretinal fibrosis (SRFib) is an important cause of permanent loss-of-vision diseases with submacular neovascularization, but a reliable diagnostic method is currently missing. This study uses polarization-sensitive optical coherence tomography (PS-OCT) to detect SRFib within retinal lesions by measurement of its birefringent collagen fibers. Methods Twenty-five patients were enrolled with retinal pathology in one or both eyes containing (1) suspected SRFib, (2) lesions suspected not to be fibrotic, or (3) lesions with doubtful presence of SRFib. All eyes were evaluated for SRFIb using conventional diagnostics by three retinal specialists. PS-OCT images were visually evaluated for SRFib based on cumulative phase retardation, local birefringence, and optic axis uniformity. Results Twenty-nine eyes from 22 patients were scanned successfully. In 13 eyes, SRFib was diagnosed by all retinal specialists; of these, 12 were confirmed by PS-OCT and one was inconclusive. In nine eyes, the retinal specialists expected no SRFib, which was confirmed by PS-OCT in all cases. In seven eyes, the retinal specialists’ evaluations were inconsistent with regard to the presence of SRFib. PS-OCT confirmed the presence of SRFib in four of these eyes and the absence of SRFib in two eyes and was inconclusive in one eye. Conclusions In 21 out of 22 eyes, PS-OCT confirmed the evaluation of retinal specialists regarding the presence of SRFib. PS-OCT provided additional information to distinguish SRFib from other tissues within subretinal neovascular lesions in 6 out of 7 eyes. Translational Relevance PS-OCT can identify and quantify SRFib in doubtful cases for which a reliable diagnosis is currently lacking.
Collapse
Affiliation(s)
- Maximilian G O Gräfe
- LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit, Amsterdam, The Netherlands
| | | | - Joy Willemse
- LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit, Amsterdam, The Netherlands
| | - Boy Braaf
- LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit, Amsterdam, The Netherlands
| | - Yvonne de Jong
- Department of Ophthalmology, Amsterdam UMC, Amsterdam, The Netherlands
| | - H Stevie Tan
- Department of Ophthalmology, Amsterdam UMC, Amsterdam, The Netherlands
| | - Frank D Verbraak
- Department of Ophthalmology, Amsterdam UMC, Amsterdam, The Netherlands
| | - Johannes F de Boer
- LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit, Amsterdam, The Netherlands.,Department of Ophthalmology, Amsterdam UMC, Amsterdam, The Netherlands
| |
Collapse
|
16
|
Willemse J, Verbraak F, de Boer J. Polarization-sensitive optical coherence tomography as a tool to visualize the fiber direction of retinal nerves and peripapillary sclera. EPJ WEB OF CONFERENCES 2020. [DOI: 10.1051/epjconf/202023804003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Polarization sensitive optical coherence tomography (PS-OCT) has been used to visualize the orientation of the nerves in the retinal nerve fiber layer (RNFL) and to visualize the orientation of the collagen fibers in peripapillary sclera in retinas of healthy volunteers. Optic axis orientation images clearly visualize the nerve fibers leaving the optic nerve head (ONH) in all radial directions. Sclera orientation images show that the sclera consist of two layers, an inner layer with an orientation parallel to the RNFL orientation, and a deeper layer where the collagen is circularly oriented.
Collapse
|
17
|
Gräfe MGO, Nadiarnykh O, De Boer JF. Optical coherence tomography velocimetry based on decorrelation estimation of phasor pair ratios (DEPPAIR). BIOMEDICAL OPTICS EXPRESS 2019; 10:5470-5485. [PMID: 31799025 PMCID: PMC6865093 DOI: 10.1364/boe.10.005470] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 09/17/2019] [Accepted: 09/20/2019] [Indexed: 05/13/2023]
Abstract
Quantitative velocity estimations in optical coherence tomography requires the estimation of the axial and lateral flow components. Optical coherence tomography measures the depth resolved complex field reflected from a sample. While the axial velocity component can be determined from the Doppler shift or phase shift between a pair of consecutive measurements at the same location, the estimation of the lateral component for in vivo applications is still challenging. One approach to determine lateral velocity is multiple simultaneous measurements at different angles. In another approach the lateral component can be retrieved through repeated measurements at (nearly) the same location by an analysis of the decorrelation over time. In this paper we follow the latter approach. We describe a model for the complex field changes between consecutive measurements and use it to predict the uncertainties for amplitude-based, phase-based and complex algorithms. The uncertainty of the flow estimations follows from a statistical analysis and is determined by the number of available measurements and the applied analysis method. The model is verified in phantom measurements and the dynamic range of velocity estimations is investigated. We demonstrate that phase-based and complex (phasor) based lateral flow estimation methods are superior to amplitude-based algorithms.
Collapse
|
18
|
Azuma S, Makita S, Kasaragod D, Sugiyama S, Miura M, Yasuno Y. Clinical multi-functional OCT for retinal imaging. BIOMEDICAL OPTICS EXPRESS 2019; 10:5724-5743. [PMID: 31799043 PMCID: PMC6865108 DOI: 10.1364/boe.10.005724] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 10/01/2019] [Accepted: 10/02/2019] [Indexed: 05/09/2023]
Abstract
A compact clinical prototype multi-functional optical coherence tomography (OCT) device for the posterior human eye has been developed. This compact Jones-matrix OCT (JM-OCT) device integrates all components into a single package. Multiple image functions, i.e., scattering intensity, OCT angiography, and the degree of polarization uniformity, are obtained. The device has the capability for measuring local birefringence. Multi-functional imaging of several eyes with age-related macular degeneration is demonstrated. The compact JM-OCT device will be useful for the in vivo non-invasive investigation of abnormal tissues.
Collapse
Affiliation(s)
- Shinnosuke Azuma
- Computational Optics Group, University of Tsukuba, 1–1–1 Tennodai, Tsukuba, Ibaraki 305–8573, Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki 305–8531, Japan
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, 1–1–1 Tennodai, Tsukuba, Ibaraki 305–8573, Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki 305–8531, Japan
| | - Deepa Kasaragod
- Computational Optics Group, University of Tsukuba, 1–1–1 Tennodai, Tsukuba, Ibaraki 305–8573, Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki 305–8531, Japan
| | | | - Masahiro Miura
- Tokyo Medical University Ibaraki Medical Center, 3–20–1 Chuo, Ami, Ibaraki 300–0395, Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki 305–8531, Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, 1–1–1 Tennodai, Tsukuba, Ibaraki 305–8573, Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki 305–8531, Japan
| |
Collapse
|
19
|
Willemse J, Gräfe MGO, van de Kreeke JA, Feroldi F, Verbraak FD, de Boer JF. Optic axis uniformity as a metric to improve the contrast of birefringent structures and analyze the retinal nerve fiber layer in polarization-sensitive optical coherence tomography. OPTICS LETTERS 2019; 44:3893-3896. [PMID: 31368995 DOI: 10.1364/ol.44.003893] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 07/02/2019] [Indexed: 05/24/2023]
Abstract
A new metric is used to improve the contrast of birefringent structures in biological tissue using polarization-sensitive optical coherence tomography. This metric, optic axis uniformity (OAxU), is based on the optic axis of birefringence and quantifies the uniformity of the optic axis direction. OAxU provides surprisingly strong contrast for fibrous structures such as muscle and the retinal nerve fiber layer (RNFL). We used OAxU for automatic segmentation of the RNFL in human eyes. From the segmentation, en face images of RNFL thickness and RNFL birefringence were created. The measured birefringence values are consistent with earlier reports.
Collapse
|
20
|
Feroldi F, Willemse J, Davidoiu V, Gräfe MGO, van Iperen DJ, Goorsenberg AWM, Annema JT, Daniels JMA, Bonta PI, de Boer JF. In vivo multifunctional optical coherence tomography at the periphery of the lungs. BIOMEDICAL OPTICS EXPRESS 2019; 10:3070-3091. [PMID: 31259075 PMCID: PMC6583343 DOI: 10.1364/boe.10.003070] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 05/13/2019] [Accepted: 05/14/2019] [Indexed: 05/04/2023]
Abstract
Remodeling of tissue, such as airway smooth muscle (ASM) and extracellular matrix, is considered a key feature of airways disease. No clinically accepted diagnostic method is currently available to assess airway remodeling or the effect of treatment modalities such as bronchial thermoplasty in asthma, other than invasive airway biopsies. Optical coherence tomography (OCT) generates cross-sectional, near-histological images of airway segments and enables identification and quantification of airway wall layers based on light scattering properties only. In this study, we used a custom motorized OCT probe that combines standard and polarization sensitive OCT (PS-OCT) to visualize birefringent tissue in vivo in the airway wall of a patient with severe asthma in a minimally invasive manner. We used optic axis uniformity (OAxU) to highlight the presence of uniformly arranged fiber-like tissue, helping visualizing the abundance of ASM and connective tissue structures. Attenuation coefficient images of the airways are presented for the first time, showing superior architectural contrast compared to standard OCT images. A novel segmentation algorithm was developed to detect the surface of the endoscope sheath and the surface of the tissue. PS-OCT is an innovative imaging technique that holds promise to assess airway remodeling including ASM and connective tissue in a minimally invasive, real-time manner.
Collapse
Affiliation(s)
- Fabio Feroldi
- LaserLaB Amsterdam and Department of Physics and Astronomy, VU University Amsterdam, de Boelelaan 1081, 1081HV, Amsterdam, the Netherlands
| | - Joy Willemse
- LaserLaB Amsterdam and Department of Physics and Astronomy, VU University Amsterdam, de Boelelaan 1081, 1081HV, Amsterdam, the Netherlands
- These authors contributed equally
| | - Valentina Davidoiu
- LaserLaB Amsterdam and Department of Physics and Astronomy, VU University Amsterdam, de Boelelaan 1081, 1081HV, Amsterdam, the Netherlands
- These authors contributed equally
| | - Maximilian G. O. Gräfe
- LaserLaB Amsterdam and Department of Physics and Astronomy, VU University Amsterdam, de Boelelaan 1081, 1081HV, Amsterdam, the Netherlands
| | - Dirck J. van Iperen
- LaserLaB Amsterdam and Department of Physics and Astronomy, VU University Amsterdam, de Boelelaan 1081, 1081HV, Amsterdam, the Netherlands
| | - Annika W. M. Goorsenberg
- Amsterdam University Medical Center, Department of Pulmonology, University of Amsterdam, Amsterdam, the Netherlands
| | - Jouke T. Annema
- Amsterdam University Medical Center, Department of Pulmonology, University of Amsterdam, Amsterdam, the Netherlands
| | - Johannes M. A. Daniels
- Amsterdam University Medical Center, Department of Pulmonology, VUmc Location, Amsterdam, the Netherlands
| | - Peter I. Bonta
- Amsterdam University Medical Center, Department of Pulmonology, University of Amsterdam, Amsterdam, the Netherlands
| | - Johannes F. de Boer
- LaserLaB Amsterdam and Department of Physics and Astronomy, VU University Amsterdam, de Boelelaan 1081, 1081HV, Amsterdam, the Netherlands
| |
Collapse
|
21
|
Yamanari M, Uematsu S, Ishihara K, Ikuno Y. Parallel detection of Jones-matrix elements in polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2019; 10:2318-2336. [PMID: 31149375 PMCID: PMC6524579 DOI: 10.1364/boe.10.002318] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/16/2019] [Accepted: 03/18/2019] [Indexed: 06/09/2023]
Abstract
The polarization properties of a sample can be characterized using a Jones matrix. To measure the Jones matrix without assumptions of the sample, two different incident states of polarization are usually used. This requirement often causes certain drawbacks in polarization-sensitive optical coherence tomography (PS-OCT), e.g., a decrease in the effective A-scan rate or axial depth range, if a multiplexing scheme is used. Because both the A-scan rate and axial depth range are important for clinical applications, including the imaging of an anterior eye segment, a new PS-OCT method that does not have these drawbacks is desired. Here, we present a parallel-detection approach that maintains the same A-scan rate and axial measurement range as conventional OCT. The interferometer consists of fiber-optic components, most of which are polarization-maintaining components with fast-axis blocking free from polarization management. When a parallel detection is implemented using swept-source OCT (SS-OCT), synchronization between the A-scans and synchronization between the detection channels have critical effects on the Jones-matrix measurement. Because it is difficult to achieve perfect synchronization using only hardware, we developed a solution using a numerical correction with signals from a static mirror. Using the developed system, we demonstrate the imaging of an anterior eye segment from the cornea to the back surface of the crystalline lens.
Collapse
Affiliation(s)
- Masahiro Yamanari
- Engineering Department, Tomey Corporation, 2-11-33 Noritakeshinmachi, Nishiku, Nagoya, Aichi, 451-0051, Japan
| | - Sato Uematsu
- Department of Ophthalmology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kenji Ishihara
- Engineering Department, Tomey Corporation, 2-11-33 Noritakeshinmachi, Nishiku, Nagoya, Aichi, 451-0051, Japan
| | - Yasushi Ikuno
- Ikuno Eye Center, 2-9-10 3F Juso-Higashi, Yodogawaku, Osaka, Osaka, 532-0023, Japan
| |
Collapse
|
22
|
Xiong Q, Wang N, Liu X, Chen S, Liang H, Chen S, Liu L. Single input state polarization-sensitive optical coherence tomography with high resolution and polarization distortion correction. OPTICS EXPRESS 2019; 27:6910-6924. [PMID: 30876266 DOI: 10.1364/oe.27.006910] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 01/23/2019] [Indexed: 06/09/2023]
Abstract
In single input state polarization-sensitive optical coherence tomography (PS-OCT) with high resolution, the imperfections of quarter-wave plate (QWP) and the sensitivity roll-off mismatch between the two detection channels cause unpredictable polarization distortion. We present a correction method based on the Jones matrix modeling of the system. In a single input PS-OCT system working at 840 nm with an axial resolution of ~2.3 μm, the method yielded better estimation of retardation and optic axis orientation with significantly reduced noise level, especially in weakly birefringent samples. Numerical simulations and quantitative imaging of a sample of known birefringence were performed to validate the performance. We further demonstrate the advantages of our approach with birefringence imaging of swine retina, rat aortic wall, and rat esophageal mucosa for potential clinical applications.
Collapse
|
23
|
Gräfe MGO, Gondre M, de Boer JF. Precision analysis and optimization in phase decorrelation OCT velocimetry. BIOMEDICAL OPTICS EXPRESS 2019; 10:1297-1314. [PMID: 30891347 PMCID: PMC6420279 DOI: 10.1364/boe.10.001297] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 01/11/2019] [Accepted: 02/12/2019] [Indexed: 05/13/2023]
Abstract
Quantitative flow velocimetry in Optical Coherence Tomography is used to determine both the axial and lateral flow component at the level of individual voxels. The lateral flow is determined by analyzing the statistical properties of reflected electro-magnetic fields for repeated measurements at (nearly) the same location. The precision or statistical fluctuation of the quantitative velocity estimation depends on the number of repeated measurements and the method to determine quantitative flow velocity. In this paper, both a method to determine quantitative flow velocity and a model for the prediction of the statistical fluctuations of velocity estimations are developed to analyze and optimize the estimation precision for phase-based velocimetry methods. The method and model are validated by phantom measurements in a bulk scattering medium as well as in intralipid solution in a capillary. Based on the model, the number of repeated measurements to achieve a certain velocimetry precision is predicted.
Collapse
Affiliation(s)
- Maximilian G. O. Gräfe
- LaserLaB, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, The Netherlands
| | - Maude Gondre
- LaserLaB, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, The Netherlands
- Université de Genève, GAP-Biophotonics, Chemin de Pinchat 22, CH-1211 Geneva 4, Switzerland
| | - Johannes F. de Boer
- LaserLaB, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, The Netherlands
| |
Collapse
|
24
|
McNabb RP, Polans J, Keller B, Jackson-Atogi M, James CL, Vann RR, Izatt JA, Kuo AN. Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation. BIOMEDICAL OPTICS EXPRESS 2019; 10:338-355. [PMID: 30775104 PMCID: PMC6363197 DOI: 10.1364/boe.10.000338] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 12/07/2018] [Accepted: 12/08/2018] [Indexed: 05/06/2023]
Abstract
Current conventional clinical OCT systems image either only the anterior or the posterior eye during a single acquisition. This localized imaging limits conventional OCT's use for characterizing global ocular morphometry and biometry, which requires knowledge of spatial relationships across the entire eye. We developed a "whole eye" optical coherence tomography system that simultaneously acquires volumes with a wide field-of-view for both the anterior chamber (14 x 14 mm) and retina (55°) using a single source and detector. This system was used to measure retinal curvature in a pilot population and compared against curvature of the same eyes measured with magnetic resonance imaging.
Collapse
Affiliation(s)
- Ryan P. McNabb
- Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710, USA
| | - James Polans
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC, 27708, USA
| | - Brenton Keller
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC, 27708, USA
| | - Moseph Jackson-Atogi
- Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710, USA
| | - Charlene L. James
- Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710, USA
| | - Robin R. Vann
- Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710, USA
| | - Joseph A. Izatt
- Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710, USA
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC, 27708, USA
| | - Anthony N. Kuo
- Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710, USA
- Department of Biomedical Engineering, Duke University, 101 Science Drive, Durham, NC, 27708, USA
| |
Collapse
|
25
|
Heemskerk E, Akca BI. On-chip polarization beam splitter design for optical coherence tomography. OPTICS EXPRESS 2018; 26:33349-33355. [PMID: 30645487 DOI: 10.1364/oe.26.033349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 11/27/2018] [Indexed: 06/09/2023]
Abstract
Polarization beam splitters (PBSs) are central elements for polarization handling. Here, we present the design of an ultra-broadband, low-loss, and easy-to-fabricate PBS based on a silicon nitride asymmetrical directional coupler for polarization-sensitive optical coherence tomography systems. The phase difference between transverse electric and transverse magnetic modes is introduced by using straight waveguides with different widths and an offset between them. A bent waveguide is placed close to the end of the through port in order to increase the operating bandwidth (i.e., more than 220 nm with greater than 15 dB of extinction). The overall device length is only 400 µm.
Collapse
|
26
|
Li Q, Karnowski K, Noble PB, Cairncross A, James A, Villiger M, Sampson DD. Robust reconstruction of local optic axis orientation with fiber-based polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9:5437-5455. [PMID: 30460138 PMCID: PMC6238922 DOI: 10.1364/boe.9.005437] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 05/19/2023]
Abstract
It is challenging to recover local optic axis orientation from samples probed with fiber-based polarization-sensitive optical coherence tomography (PS-OCT). In addition to the effect of preceding tissue layers, the transmission through fiber and system elements, and imperfect system alignment, need to be compensated. Here, we present a method to retrieve the required correction factors from measurements with depth-multiplexed PS-OCT, which accurately measures the full Jones matrix. The correction considers both retardation and diattenuation and is applied in the wavenumber domain, preserving the axial resolution of the system. The robustness of the method is validated by measuring a birefringence phantom with a misaligned system. Imaging ex-vivo lamb trachea and human bronchus demonstrates the utility of reconstructing the local optic axis orientation to assess smooth muscle, which is expected to be useful in the assessment of airway smooth muscle thickness in asthma, amongst other fiber-based applications.
Collapse
Affiliation(s)
- Qingyun Li
- Optical + Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA 6009,
Australia
| | - Karol Karnowski
- Optical + Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA 6009,
Australia
| | - Peter B. Noble
- School of Human Sciences, The University of Western Australia, Perth, WA 6009,
Australia
| | - Alvenia Cairncross
- School of Human Sciences, The University of Western Australia, Perth, WA 6009,
Australia
| | - Alan James
- Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Perth,
Australia
| | - Martin Villiger
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, Boston, MA,
USA
| | - David D. Sampson
- Optical + Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, The University of Western Australia, Perth, WA 6009,
Australia
- University of Surrey, Guildford, GU2 7XH, Surrey,
United Kingdom
| |
Collapse
|
27
|
Villiger M, Braaf B, Lippok N, Otsuka K, Nadkarni SK, Bouma BE. Optic axis mapping with catheter-based polarization-sensitive optical coherence tomography. OPTICA 2018; 5:1329-1337. [PMID: 31214632 PMCID: PMC6581518 DOI: 10.1364/optica.5.001329] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Birefringence offers an intrinsic contrast mechanism related to the microstructure and arrangement of fibrillary tissue components. Here we present a reconstruction strategy to recover not only the scalar amount of birefringence but also its optic axis orientation as a function of depth in tissue from measurements with catheter-based polarization sensitive optical coherence tomography. A polarization symmetry constraint, intrinsic to imaging in the backscatter direction, facilitates the required compensation for wavelength-dependent transmission through system elements, the rotating catheter, and overlying tissue layers. Applied to intravascular imaging of coronary atherosclerosis in human patients, the optic axis affords refined interpretation of plaque architecture.
Collapse
Affiliation(s)
- Martin Villiger
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA, USA
- Corresponding author:
| | - Boy Braaf
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA, USA
| | - Norman Lippok
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA, USA
| | - Kenichiro Otsuka
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA, USA
| | - Seemantini K. Nadkarni
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA, USA
| | - Brett E. Bouma
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA, USA
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|
28
|
Leitgeb RA, Baumann B. Multimodal Optical Medical Imaging Concepts Based on Optical Coherence Tomography. FRONTIERS IN PHYSICS 2018; 6. [PMID: 0 DOI: 10.3389/fphy.2018.00114] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
29
|
Baumann B, Augustin M, Lichtenegger A, Harper D, Muck M, Eugui P, Wartak A, Pircher M, Hitzenberger C. Polarization-sensitive optical coherence tomography imaging of the anterior mouse eye. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-12. [PMID: 30168301 DOI: 10.1117/1.jbo.23.8.086005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 08/14/2018] [Indexed: 05/20/2023]
Abstract
Polarization-sensitive optical coherence tomography (PS-OCT) enables noninvasive, high-resolution imaging of tissue polarization properties. In the anterior segments of human eyes, PS-OCT allows the visualization of birefringent and depolarizing structures. We present the use of PS-OCT for imaging the murine anterior eye. Using a spectral domain PS-OCT setup operating in the 840-nm regime, we performed in vivo volumetric imaging in anesthetized C57BL/6 mice. The polarization properties of murine anterior eye structures largely replicated those known from human PS-OCT imagery, suggesting that the mouse eye may also serve as a model system under polarization contrast. However, dissimilarities were found in the depolarizing structure of the iris which, as we confirmed in postmortem histological sections, were caused by anatomical differences between both species. In addition to the imaging of tissues in the anterior chamber and the iridocorneal angle, we demonstrate longitudinal PS-OCT imaging of the murine anterior segment during mydriasis as well as birefringence imaging of corneal pathology in an aged mouse.
Collapse
Affiliation(s)
| | | | | | | | - Martina Muck
- Medizinische Univ. Wien, Austria
- Allgemeines Krankenhaus der Stadt Wien, Austria
| | | | | | | | | |
Collapse
|
30
|
Cense B, Miller DT, King BJ, Theelen T, Elsner AE. Measuring polarization changes in the human outer retina with polarization-sensitive optical coherence tomography. JOURNAL OF BIOPHOTONICS 2018; 11:e201700134. [PMID: 29282883 PMCID: PMC6596294 DOI: 10.1002/jbio.201700134] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 12/25/2017] [Accepted: 12/25/2017] [Indexed: 05/02/2023]
Abstract
Morphological changes in the outer retina such as drusen are established biomarkers to diagnose age-related macular degeneration. However, earlier diagnosis might be possible by taking advantage of more subtle changes that accompany tissues that bear polarization-altering properties. To test this hypothesis, we developed a method based on polarization-sensitive optical coherence tomography with which volumetric data sets of the macula were obtained from 10 young (<25 years) and 10 older (>54 years) subjects. All young subjects and 5 of the older subjects had retardance values induced by the retinal pigment epithelium and Bruch's membrane (RPE-BM) complex that were just above the noise floor measurement (5°-13° at 840 nm). In contrast, elevated retardance, up to 180°, was observed in the other 5 older subjects. Analysis of the degree of polarization uniformity (DOPU) demonstrates that reduced DOPU (<0.4) in the RPE is associated with elevated double pass phase retardation (DPPR) below the RPE-BM complex, suggesting that the observed elevated DPPR in older subjects is the result of increased scattering or polarization scrambling. Collectively, our measurements show that the outer retina can undergo dramatic change in its polarization properties with age, and in some cases still retain its clinically normal appearance.
Collapse
Affiliation(s)
- Barry Cense
- Center for Optical Research and Education, Utsunomiya University, Utsunomiya, Japan
- Correspondence: Barry Cense, Center for Optical Research and Education, Utsunomiya University, Utsunomiya, Tochigi 321-8585, Japan.
| | | | - Brett J. King
- School of Optometry, Indiana University, Bloomington, Indiana
| | - Thomas Theelen
- Department of Ophthalmology, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Ann E. Elsner
- School of Optometry, Indiana University, Bloomington, Indiana
| |
Collapse
|
31
|
Harper DJ, Augustin M, Lichtenegger A, Eugui P, Reyes C, Glösmann M, Hitzenberger CK, Baumann B. White light polarization sensitive optical coherence tomography for sub-micron axial resolution and spectroscopic contrast in the murine retina. BIOMEDICAL OPTICS EXPRESS 2018; 9:2115-2129. [PMID: 29760974 PMCID: PMC5946775 DOI: 10.1364/boe.9.002115] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 03/29/2018] [Accepted: 03/30/2018] [Indexed: 05/03/2023]
Abstract
A white light polarization sensitive optical coherence tomography system has been developed, using a supercontinuum laser as the light source. By detecting backscattered light from 400 - 700 nm, an axial resolution of 1.0 µm in air was achieved. The system consists of a free-space interferometer and two homemade spectrometers that detect orthogonal polarization states. Following system specifications, images of a healthy murine retina as acquired by this non-contact system are presented, showing high resolution reflectivity images as well as spectroscopic and polarization sensitive contrast. Additional images of the very-low-density-lipoprotein-receptor (VLDLR) knockout mouse model were acquired. The high resolution allows the detection of small lesions in the retina.
Collapse
Affiliation(s)
- Danielle J. Harper
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Marco Augustin
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Antonia Lichtenegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Pablo Eugui
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Carlos Reyes
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Martin Glösmann
- University of Veterinary Medicine Vienna, Core Facility for Research and Technology, Veterinaerplatz 1, 1210 Vienna,
Austria
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, 1090 Vienna,
Austria
| |
Collapse
|
32
|
Braaf B, Donner S, Nam AS, Bouma BE, Vakoc BJ. Complex differential variance angiography with noise-bias correction for optical coherence tomography of the retina. BIOMEDICAL OPTICS EXPRESS 2018; 9:486-506. [PMID: 29552388 PMCID: PMC5854053 DOI: 10.1364/boe.9.000486] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 01/03/2018] [Accepted: 01/03/2018] [Indexed: 05/05/2023]
Abstract
Complex differential variance (CDV) provides phase-sensitive angiographic imaging for optical coherence tomography (OCT) with immunity to phase-instabilities of the imaging system and small-scale axial bulk motion. However, like all angiographic methods, measurement noise can result in erroneous indications of blood flow that confuse the interpretation of angiographic images. In this paper, a modified CDV algorithm that corrects for this noise-bias is presented. This is achieved by normalizing the CDV signal by analytically derived upper and lower limits. The noise-bias corrected CDV algorithm was implemented into an experimental 1 μm wavelength OCT system for retinal imaging that used an eye tracking scanner laser ophthalmoscope at 815 nm for compensation of lateral eye motions. The noise-bias correction improved the CDV imaging of the blood flow in tissue layers with a low signal-to-noise ratio and suppressed false indications of blood flow outside the tissue. In addition, the CDV signal normalization suppressed noise induced by galvanometer scanning errors and small-scale lateral motion. High quality cross-section and motion-corrected en face angiograms of the retina and choroid are presented.
Collapse
Affiliation(s)
- Boy Braaf
- Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, Massachusetts 02114, USA
- Harvard Medical School, 25 Shattuck Street, Boston, Massachusetts 02115, USA
| | - Sabine Donner
- Heidelberg Engineering GmbH, Max-Jarecki-Straße 8, 69115 Heidelberg, Germany
| | - Ahhyun S. Nam
- Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, Massachusetts 02114, USA
- Harvard Medical School, 25 Shattuck Street, Boston, Massachusetts 02115, USA
| | - Brett E. Bouma
- Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, Massachusetts 02114, USA
- Harvard Medical School, 25 Shattuck Street, Boston, Massachusetts 02115, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139, USA
| | - Benjamin J. Vakoc
- Wellman Center for Photomedicine, Massachusetts General Hospital, 50 Blossom St., Boston, Massachusetts 02114, USA
- Harvard Medical School, 25 Shattuck Street, Boston, Massachusetts 02115, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139, USA
| |
Collapse
|
33
|
Adams DC, Hariri LP, Miller AJ, Wang Y, Cho JL, Villiger M, Holz JA, Szabari MV, Hamilos DL, Scott Harris R, Griffith JW, Bouma BE, Luster AD, Medoff BD, Suter MJ. Birefringence microscopy platform for assessing airway smooth muscle structure and function in vivo. Sci Transl Med 2017; 8:359ra131. [PMID: 27708064 DOI: 10.1126/scitranslmed.aag1424] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2016] [Accepted: 08/19/2016] [Indexed: 12/30/2022]
Abstract
The inability to visualize airway smooth muscle (ASM) cells in vivo is a major obstacle in understanding their role in normal physiology and diseases. At present, there is no imaging modality available to assess ASM in vivo. Confocal endomicroscopy lacks the penetration depth and field of view, and conventional optical coherence tomography (OCT) does not have sufficient contrast to differentiate ASM from surrounding tissues. We have developed a birefringence microscopy platform that leverages the micro-organization of tissue to add further dimension to traditional OCT. We have used this technology to validate ASM measurements in ex vivo swine and canine studies, visualize and characterize volumetric representations of ASM in vivo, and quantify and predict ASM contractile force as a function of optical retardation. We provide in vivo images and volumetric assessments of ASM in living humans and document structural disease variations in subjects with mild asthma. The opportunity to link inflammatory responses to ASM responses and to link ASM responses to clinical responses and outcomes could lead to an increased understanding of diseases of the airway and, ultimately, to improved patient outcomes.
Collapse
Affiliation(s)
- David C Adams
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Lida P Hariri
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Alyssa J Miller
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Yan Wang
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Josalyn L Cho
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Center for Immunology and Inflammatory Diseases, Division of Rheumatology, Allergy and Immunology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Martin Villiger
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Jasmin A Holz
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Margit V Szabari
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Daniel L Hamilos
- Center for Immunology and Inflammatory Diseases, Division of Rheumatology, Allergy and Immunology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - R Scott Harris
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Jason W Griffith
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Center for Immunology and Inflammatory Diseases, Division of Rheumatology, Allergy and Immunology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Brett E Bouma
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Andrew D Luster
- Center for Immunology and Inflammatory Diseases, Division of Rheumatology, Allergy and Immunology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Benjamin D Medoff
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Center for Immunology and Inflammatory Diseases, Division of Rheumatology, Allergy and Immunology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Melissa J Suter
- Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
| |
Collapse
|
34
|
Attenuation Coefficients From SD-OCT Data: Structural Information Beyond Morphology on RNFL Integrity in Glaucoma. J Glaucoma 2017; 26:1001-1009. [PMID: 28858153 DOI: 10.1097/ijg.0000000000000764] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this study is to explore the attenuation coefficient (AC) of the retinal nerve fiber layer (RNFL) in spectral domain optical coherence tomography (OCT) images, in healthy eyes and eyes affected by glaucoma. To assess the relation between RNLF AC, disease severity, RNFL thickness, visual field sensitivity threshold, spatial location and age. PATIENTS AND METHODS We analyzed peripapillary circle scans of a clinical OCT device (Spectralis OCT, Heidelberg Engineering, Heidelberg, Germany) in 102 glaucoma patients and 90 healthy controls. The images were fully automatically converted into depth-resolved AC images. Next, the median AC within the RNFL was calculated based on the Spectralis segmentation. We compared the RNFL AC between healthy, mild, moderate and advanced glaucomatous eyes and assessed the correlation with patient characteristics such as age and visual field sensitivity threshold (HFA, Carl Zeiss Meditec, Dublin, CA) in a generalized estimating equations (GEE) model. Finally, we explored the ability to discriminate between glaucomatous and healthy eyes by RNFL AC. RESULTS Median RNFL AC decreased with increasing disease severity up to moderate glaucoma (P<0.001) in all 4 sectors around the optic nerve head. The largest relative decrease occurred in the nasal sector. The RNFL AC (AUC, 0.834±0.028) effectively discriminated healthy from glaucomatous eyes, although RNFL thickness (AUC, 0.975±0.013) performed even better (P<0.001). Prediction of visual field sensitivity improved significantly when RNFL thickness was augmented with RNFL AC as covariates (P<0.001). CONCLUSIONS This study demonstrated that RNFL AC provides complementary information on the RNFL's health compared with RNFL thickness measurements alone.
Collapse
|
35
|
Rivet S, Marques MJ, Bradu A, Podoleanu A. Passive optical module for polarization-sensitive optical coherence tomography systems. OPTICS EXPRESS 2017; 25:14533-14544. [PMID: 28789039 DOI: 10.1364/oe.25.014533] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Accepted: 05/30/2017] [Indexed: 06/07/2023]
Abstract
The paper presents a proof-of-concept polarization-sensitive swept source optical coherence tomography (OCT) system that performs measurements of the retardance as well as of the axis orientation of a linear birefringent sample. The system performs single input state polarization-sensitive OCT and employs an optical module based on optically passive elements such as two beam displacers and a Faraday rotator. Our implementation of the PS-OCT system does not need any calibration step to compensate for the polarimetric effect of the fibers, and its operation does not require a balanced polarization-diversity detector. The optical module allows measurement of the two polarization properties of the sample via two measurements which are performed simultaneously.
Collapse
|
36
|
Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7050474] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
37
|
Chan AC, Hong YJ, Makita S, Miura M, Yasuno Y. Noise-bias and polarization-artifact corrected optical coherence tomography by maximum a-posteriori intensity estimation. BIOMEDICAL OPTICS EXPRESS 2017; 8:2069-2087. [PMID: 28736656 PMCID: PMC5516815 DOI: 10.1364/boe.8.002069] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 02/22/2017] [Accepted: 02/24/2017] [Indexed: 05/05/2023]
Abstract
We propose using maximum a-posteriori (MAP) estimation to improve the image signal-to-noise ratio (SNR) in polarization diversity (PD) optical coherence tomography. PD-detection removes polarization artifacts, which are common when imaging highly birefringent tissue or when using a flexible fiber catheter. However, dividing the probe power to two polarization detection channels inevitably reduces the SNR. Applying MAP estimation to PD-OCT allows for the removal of polarization artifacts while maintaining and improving image SNR. The effectiveness of the MAP-PD method is evaluated by comparing it with MAP-non-PD, intensity averaged PD, and intensity averaged non-PD methods. Evaluation was conducted in vivo with human eyes. The MAP-PD method is found to be optimal, demonstrating high SNR and artifact suppression, especially for highly birefringent tissue, such as the peripapillary sclera. The MAP-PD based attenuation coefficient image also shows better differentiation of attenuation levels than non-MAP attenuation images.
Collapse
Affiliation(s)
- Aaron C. Chan
- Computational Optics Group, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki, 305-8573,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Young-Joo Hong
- Computational Optics Group, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki, 305-8573,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki, 305-8573,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Masahiro Miura
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
- Department of Ophthalmology, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Ibaraki,
Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki, 305-8573,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| |
Collapse
|
38
|
de Boer JF, Hitzenberger CK, Yasuno Y. Polarization sensitive optical coherence tomography - a review [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:1838-1873. [PMID: 28663869 PMCID: PMC5480584 DOI: 10.1364/boe.8.001838] [Citation(s) in RCA: 190] [Impact Index Per Article: 27.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/16/2017] [Accepted: 02/16/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) is now a well-established modality for high-resolution cross-sectional and three-dimensional imaging of transparent and translucent samples and tissues. Conventional, intensity based OCT, however, does not provide a tissue-specific contrast, causing an ambiguity with image interpretation in several cases. Polarization sensitive (PS) OCT draws advantage from the fact that several materials and tissues can change the light's polarization state, adding an additional contrast channel and providing quantitative information. In this paper, we review basic and advanced methods of PS-OCT and demonstrate its use in selected biomedical applications.
Collapse
Affiliation(s)
- Johannes F. de Boer
- Department of Physics and Astronomy, LaserLaB Amsterdam, VU University, Amsterdam, The Netherlands
- Authors were listed in alphabetical order and contributed equally to the manuscript
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
- Authors were listed in alphabetical order and contributed equally to the manuscript
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, Tsukuba, Japan
- Authors were listed in alphabetical order and contributed equally to the manuscript
| |
Collapse
|
39
|
Yamanari M, Tsuda S, Kokubun T, Shiga Y, Omodaka K, Aizawa N, Yokoyama Y, Himori N, Kunimatsu-Sanuki S, Maruyama K, Kunikata H, Nakazawa T. Estimation of Jones matrix, birefringence and entropy using Cloude-Pottier decomposition in polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2016; 7:3551-3573. [PMID: 27699120 PMCID: PMC5030032 DOI: 10.1364/boe.7.003551] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 08/13/2016] [Accepted: 08/13/2016] [Indexed: 05/18/2023]
Abstract
Estimation of polarimetric parameters has been a fundamental issue to assess biological tissues that have form birefringence or polarization scrambling in polarization-sensitive optical coherence tomography (PS-OCT). We present a mathematical framework to provide a maximum likelihood estimation of the target covariance matrix and its incoherent target decomposition to estimate a Jones matrix of a dominant scattering mechanism, called Cloude-Pottier decomposition, thereby deriving the phase retardation and the optic axis of the sample. In addition, we introduce entropy that shows the randomness of the polarization property. Underestimation of the entropy at a low sampling number is mitigated by asymptotic quasi maximum likelihood estimator. A bias of the entropy from random noises is corrected to show only the polarization property inherent in the sample. The theory is validated with experimental measurements of a glass plate and waveplates, and applied to the imaging of a healthy human eye anterior segment as an image filter.
Collapse
Affiliation(s)
- Masahiro Yamanari
- Department of Technology Development, Tomey Corporation, 2-11-33 Noritakeshinmachi, Nishi-ku, Nagoya, Aichi, 451-0051, Japan;
| | - Satoru Tsuda
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Taiki Kokubun
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Yukihiro Shiga
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Kazuko Omodaka
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Naoko Aizawa
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Yu Yokoyama
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Noriko Himori
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Shiho Kunimatsu-Sanuki
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Kazuichi Maruyama
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Hiroshi Kunikata
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan
| | - Toru Nakazawa
- Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan;
| |
Collapse
|
40
|
Villiger M, Lorenser D, McLaughlin RA, Quirk BC, Kirk RW, Bouma BE, Sampson DD. Deep tissue volume imaging of birefringence through fibre-optic needle probes for the delineation of breast tumour. Sci Rep 2016; 6:28771. [PMID: 27364229 PMCID: PMC4929466 DOI: 10.1038/srep28771] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Accepted: 06/10/2016] [Indexed: 01/13/2023] Open
Abstract
Identifying tumour margins during breast-conserving surgeries is a persistent challenge. We have previously developed miniature needle probes that could enable intraoperative volume imaging with optical coherence tomography. In many situations, however, scattering contrast alone is insufficient to clearly identify and delineate malignant regions. Additional polarization-sensitive measurements provide the means to assess birefringence, which is elevated in oriented collagen fibres and may offer an intrinsic biomarker to differentiate tumour from benign tissue. Here, we performed polarization-sensitive optical coherence tomography through miniature imaging needles and developed an algorithm to efficiently reconstruct images of the depth-resolved tissue birefringence free of artefacts. First ex vivo imaging of breast tumour samples revealed excellent contrast between lowly birefringent malignant regions, and stromal tissue, which is rich in oriented collagen and exhibits higher birefringence, as confirmed with co-located histology. The ability to clearly differentiate between tumour and uninvolved stroma based on intrinsic contrast could prove decisive for the intraoperative assessment of tumour margins.
Collapse
Affiliation(s)
- Martin Villiger
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA USA
| | - Dirk Lorenser
- Optical+Biomedical Engineering Laboratory, The University of Western Australia, Perth, WA 6009, Australia
| | - Robert A. McLaughlin
- Optical+Biomedical Engineering Laboratory, The University of Western Australia, Perth, WA 6009, Australia
| | - Bryden C. Quirk
- Optical+Biomedical Engineering Laboratory, The University of Western Australia, Perth, WA 6009, Australia
| | - Rodney W. Kirk
- Optical+Biomedical Engineering Laboratory, The University of Western Australia, Perth, WA 6009, Australia
| | - Brett E. Bouma
- Harvard Medical School and Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, MA USA
- Harvard-Massachusetts Institute of Technology, Program in Health Sciences and Technology, Cambridge, MA 02142, USA
| | - David D. Sampson
- Optical+Biomedical Engineering Laboratory, The University of Western Australia, Perth, WA 6009, Australia
- Centre for Microscopy, Characterisation and Analysis, The University of Western Australia, Perth, WA 6009, Australia
| |
Collapse
|
41
|
Fialová S, Augustin M, Glösmann M, Himmel T, Rauscher S, Gröger M, Pircher M, Hitzenberger CK, Baumann B. Polarization properties of single layers in the posterior eyes of mice and rats investigated using high resolution polarization sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2016; 7:1479-95. [PMID: 27446670 PMCID: PMC4929656 DOI: 10.1364/boe.7.001479] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 03/11/2016] [Accepted: 03/14/2016] [Indexed: 05/19/2023]
Abstract
We present a high resolution polarization sensitive optical coherence tomography (PS-OCT) system for ocular imaging in rodents. The system operates at 840 nm and uses a broadband superluminescent diode providing an axial resolution of 5.1 µm in air. PS-OCT data was acquired at 83 kHz A-scan rate by two identical custom-made spectrometers for orthogonal polarization states. Pigmented (Brown Norway, Long Evans) and non-pigmented (Sprague Dawley) rats as well as pigmented mice (C57BL/6) were imaged. Melanin pigment related depolarization was analyzed in the retinal pigment epithelium (RPE) and choroid of these animals using the degree of polarization uniformity (DOPU). For all rat strains, significant differences between RPE and choroidal depolarization were observed. In contrast, DOPU characteristics of RPE and choroid were similar for C57BL/6 mice. Moreover, the depolarization within the same tissue type varied significantly between different rodent strains. Retinal nerve fiber layer thickness, phase retardation, and birefringence were mapped and quantitatively measured in Long Evans rats in vivo for the first time. In a circumpapillary annulus, retinal nerve fiber layer birefringence amounted to 0.16°/µm ± 0.02°/µm and 0.17°/µm ± 0.01°/µm for the left and right eyes, respectively.
Collapse
Affiliation(s)
- Stanislava Fialová
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20, 1090 Vienna, Austria
| | - Marco Augustin
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20, 1090 Vienna, Austria
| | - Martin Glösmann
- University of Veterinary Medicine Vienna, Core Facility for Research and Technology, Veterinärplatz 1, 1210 Vienna, Austria
| | - Tanja Himmel
- University of Veterinary Medicine Vienna, Core Facility for Research and Technology, Veterinärplatz 1, 1210 Vienna, Austria
| | - Sabine Rauscher
- Medical University of Vienna, Core Facility Imaging, Lazarettgasse 14, 1090 Vienna, Austria
| | - Marion Gröger
- Medical University of Vienna, Core Facility Imaging, Lazarettgasse 14, 1090 Vienna, Austria
| | - Michael Pircher
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20, 1090 Vienna, Austria
| | - Christoph K. Hitzenberger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20, 1090 Vienna, Austria
| | - Bernhard Baumann
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20, 1090 Vienna, Austria
| |
Collapse
|
42
|
Makita S, Kurokawa K, Hong YJ, Miura M, Yasuno Y. Noise-immune complex correlation for optical coherence angiography based on standard and Jones matrix optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2016; 7:1525-48. [PMID: 27446673 PMCID: PMC4929659 DOI: 10.1364/boe.7.001525] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2016] [Revised: 03/24/2016] [Accepted: 03/24/2016] [Indexed: 05/18/2023]
Abstract
This paper describes a complex correlation mapping algorithm for optical coherence angiography (cmOCA). The proposed algorithm avoids the signal-to-noise ratio dependence and exhibits low noise in vasculature imaging. The complex correlation coefficient of the signals, rather than that of the measured data are estimated, and two-step averaging is introduced. Algorithms of motion artifact removal based on non perfusing tissue detection using correlation are developed. The algorithms are implemented with Jones-matrix OCT. Simultaneous imaging of pigmented tissue and vasculature is also achieved using degree of polarization uniformity imaging with cmOCA. An application of cmOCA to in vivo posterior human eyes is presented to demonstrate that high-contrast images of patients' eyes can be obtained.
Collapse
Affiliation(s)
- Shuichi Makita
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573,
Japan
| | - Kazuhiro Kurokawa
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573,
Japan
| | - Young-Joo Hong
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573,
Japan
| | - Masahiro Miura
- Department of Ophthalmology, Tokyo Medical University Ibaraki Medical Center, 3-20-1 Chuo, Ami, Inashiki, Ibaraki 300-0395,
Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573,
Japan
| |
Collapse
|
43
|
Sugiyama S, Hong YJ, Kasaragod D, Makita S, Uematsu S, Ikuno Y, Miura M, Yasuno Y. Birefringence imaging of posterior eye by multi-functional Jones matrix optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2015; 6:4951-74. [PMID: 26713208 PMCID: PMC4679268 DOI: 10.1364/boe.6.004951] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/12/2015] [Accepted: 11/13/2015] [Indexed: 05/18/2023]
Abstract
A clinical grade prototype of posterior multifunctional Jones matrix optical coherence tomography (JM-OCT) is presented. This JM-OCT visualized depth-localized birefringence in addition to conventional cumulative phase retardation imaging through local Jones matrix analysis. In addition, it simultaneously provides a sensitivity enhanced scattering OCT, a quantitative polarization uniformity contrast, and OCT-based angiography. The probe beam is at 1-μm wavelength band. The measurement speed and the depth-resolution were 100,000 A-lines/s, and 6.6 μm in tissue, respectively. Normal and pathologic eyes are examined and several clinical features are revealed, which includes high birefringence in the choroid and lamina cribrosa, and birefringent layered structure of the sclera. The theoretical details of the depth-localized birefringence imaging and conventional phase retardation imaging are formulated. This formulation indicates that the birefringence imaging correctly measures a depth-localized single-trip phase retardation of a tissue, while the conventional phase retardation can provide correct single-trip phase retardation only for some specific types of samples.
Collapse
Affiliation(s)
- Satoshi Sugiyama
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki,
Japan
- Tomey Corporation, Nagoya, Aichi,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Young-Joo Hong
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Deepa Kasaragod
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Shuichi Makita
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| | - Sato Uematsu
- Department of Ophthalmology, Osaka University Hospital, Suita, Osaka,
Japan
| | - Yasushi Ikuno
- Department of Ophthalmology, Osaka University Hospital, Suita, Osaka,
Japan
| | - Masahiro Miura
- Tokyo Medical University Ibaraki Medical Center, Ami, Ibaraki,
Japan
| | - Yoshiaki Yasuno
- Computational Optics Group, University of Tsukuba, Tsukuba, Ibaraki,
Japan
- Computational Optics and Ophthalmology Group, Tsukuba, Ibaraki,
Japan
| |
Collapse
|
44
|
Fortune B, Cull G, Reynaud J, Wang L, Burgoyne CF. Relating Retinal Ganglion Cell Function and Retinal Nerve Fiber Layer (RNFL) Retardance to Progressive Loss of RNFL Thickness and Optic Nerve Axons in Experimental Glaucoma. Invest Ophthalmol Vis Sci 2015; 56:3936-44. [PMID: 26087359 DOI: 10.1167/iovs.15-16548] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To relate changes in retinal function and retinal nerve fiber layer (RNFL) retardance to loss of RNFL thickness and optic nerve axon counts in a nonhuman primate (NHP) model of experimental glaucoma (EG). METHODS Bilateral longitudinal measurements of peripapillary RNFL thickness (spectral-domain optical coherence tomography, SDOCT; Spectralis), retardance (GDxVCC), and multifocal electroretinography (mfERG; VERIS) were performed in 39 NHP at baseline (BL; median, 5 recordings; range, 3-10) and weekly after induction of unilateral EG by laser photocoagulation of the trabecular meshwork. Multifocal ERG responses were high-pass filtered (>75 Hz) to measure high- and low-frequency component (HFC and LFC) amplitudes, including LFC features N1, P1, and N2. High-frequency component amplitudes are known to specifically reflect retinal ganglion cell (RGC) function. Complete (100%) axon counts of orbital optic nerves were obtained in 31/39 NHP. RESULTS Postlaser follow-up was 10.4 ± 7.9 months; mean and peak IOP were 18 ± 5 and 41 ± 11 mm Hg in EG eyes, 11 ± 2 and 18 ± 6 mm Hg in control (CTL) eyes. At the final available time point, RNFL thickness had decreased from BL by 14 ± 14%, retardance by 20 ± 11%, and the mfERG HFC by 30 ± 17% (P < 0.0001 each). Longitudinal changes in retardance and HFC were linearly related to RNFL thickness change (R2 = 0.51, P < 0.0001 and R2 = 0.22, P = 0.002, respectively); LFC N2 was weakly related but N1 or P2 (N1: R2 = 0.07, P = 0.11; P1: R2 = 0.04, P = 0.24; N2: R2 = 0.13, P = 0.02). At zero change from BL for RNFL thickness (Y-intercept), retardance was reduced by 11% (95% confidence interval [CI]: -15.3% to -6.8%) and HFC by 21.5% (95% CI: -28.7% to -14.3%). Relative loss of RNFL thickness, retardance, and HFC (EG:CTL) were each related to axon loss (R2 = 0.66, P < 0.0001; R2 = 0.42, P < 0.0001; R2 = 0.42, P < 0.0001, respectively), but only retardance and HFC were significantly reduced at zero relative axon loss (Y-intercept; retardance: -9.4%, 95% CI: -15.5% to -3.4%; HFC: -10.9%, 95% CI: -18.6% to -3.2%; RNFL thickness: +1.8%, 95% CI: -4.9% to +5.4%). CONCLUSIONS Retinal nerve fiber layer retardance and RGC function exhibit progressive loss from baseline before any loss of RNFL thickness or orbital optic nerve axons occurs in NHP EG. These in vivo measures might serve as potential biomarkers of early-stage glaucomatous damage preceding axon loss and RGC death.
Collapse
|
45
|
Marques MJ, Rivet S, Bradu A, Podoleanu A. Polarization-sensitive optical coherence tomography system tolerant to fiber disturbances using a line camera. OPTICS LETTERS 2015; 40:3858-3861. [PMID: 26274678 DOI: 10.1364/ol.40.003858] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This Letter presents a spectral-domain, polarization-sensitive optical coherence tomography (PS-OCT) system, where the light collection from the two arms of the interferometer is performed exclusively using single-mode fibers and couplers, and the two orthogonal polarization components are sequentially detected by a single line camera. Retardance measurements can be affected by polarimetric effects because of fiber birefringence and diattenuation in fiber couplers. This configuration bypasses such issues by performing polarization selection before the collection fiber through the combination of a polarization rotator and a linear polarizer. Retardance calibration is achieved with a Berek compensator. Similar net retardance maps of a birefringent phantom are obtained for two different settings of induced fiber birefringence, effectively demonstrating the tolerance of the configuration to fiber-based disturbances.
Collapse
|
46
|
Schütze C, Teleky K, Baumann B, Pircher M, Götzinger E, Hitzenberger CK, Schmidt-Erfurth U. Polarisation-sensitive OCT is useful for evaluating retinal pigment epithelial lesions in patients with neovascular AMD. Br J Ophthalmol 2015; 100:371-7. [PMID: 26183936 PMCID: PMC4789720 DOI: 10.1136/bjophthalmol-2015-306607] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Accepted: 06/19/2015] [Indexed: 11/23/2022]
Abstract
Background/aims To examine the reproducibility of lesion dimensions of the retinal pigment epithelium (RPE) in neovascular age-related macular degeneration (AMD) with polarisation-sensitive optical coherence tomography (PS-OCT), specifically imaging the RPE. Methods Twenty-six patients (28 eyes) with neovascular AMD were included in this study, and examined by a PS-OCT prototype. Each patient was scanned five times at a 1-day visit. The PS-OCT B-scan located closest to the macular centre presenting with RPE atrophy was identified, and the longitudinal diameter of the lesion was quantified manually using AutoCAD 2008. This procedure was followed for the identical B-scan position in all five scans per eye and patient. Reproducibility of qualitative changes in PS-OCT was evaluated. Interobserver variability was assessed. Results were compared with intensity-based spectral-domain OCT (SD-OCT) imaging. Results Mean variability of all atrophy lesion dimensions was 0.10 mm (SD±=0.06 mm). Coefficient of variation (SD±/mean) was 0.06 on average (SD±=0.03). Interobserver variability assessment showed a mean difference of 0.02 mm across all patients regarding RPE lesion size evaluation (paired t test: p=0.38). Spearman correlation coefficient was r=0.98, p<0.001. Results revealed a good overall reproducibility of ∼90%. PS-OCT specifically detected the RPE in all eyes compared with conventional intensity-based SD-OCT that was not capable to clearly identify RPE atrophy in 25 eyes (89.3%, p<0.01). Conclusions PS-OCT offers good reproducibility of RPE atrophy assessment in neovascular AMD, and may be suitable for precise RPE evaluation in clinical practice. PS-OCT unambiguously identifies RPE changes in choroidal neovascularisation compared with intensity-based SD-OCT that does not identify the RPE status reliably.
Collapse
Affiliation(s)
| | - Katharina Teleky
- Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Erich Götzinger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Christoph K Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | | |
Collapse
|
47
|
Fortune B. In vivo imaging methods to assess glaucomatous optic neuropathy. Exp Eye Res 2015; 141:139-53. [PMID: 26048475 DOI: 10.1016/j.exer.2015.06.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2015] [Revised: 05/13/2015] [Accepted: 06/01/2015] [Indexed: 10/23/2022]
Abstract
The goal of this review is to summarize the most common imaging methods currently applied for in vivo assessment of ocular structure in animal models of experimental glaucoma with an emphasis on translational relevance to clinical studies of the human disease. The most common techniques in current use include optical coherence tomography and scanning laser ophthalmoscopy. In reviewing the application of these and other imaging modalities to study glaucomatous optic neuropathy, this article is organized into three major sections: 1) imaging the optic nerve head, 2) imaging the retinal nerve fiber layer and 3) imaging retinal ganglion cell soma and dendrites. The article concludes with a brief section on possible future directions.
Collapse
Affiliation(s)
- Brad Fortune
- Discoveries in Sight Research Laboratories, Devers Eye Institute and Legacy Research Institute, Legacy Health, 1225 NE Second Avenue, Portland, OR 97232, USA.
| |
Collapse
|
48
|
Yoon Y, Li Q, Le VH, Jang WH, Wang T, Kim B, Son S, Chung WK, Joo C, Kim KH. Dark-field polarization-sensitive optical coherence tomography. OPTICS EXPRESS 2015; 23:12874-86. [PMID: 26074541 DOI: 10.1364/oe.23.012874] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Polarization-sensitive optical coherence tomography (PS-OCT) is a functional OCT providing both structural and birefringent information of the sample, and it has been applied to the studies of various organs having polarization properties. Fiber-based PS-OCT is sensitive to specular reflection from the sample surface, because signal saturation due to the strong specular reflection can make the polarization measurement difficult. We developed a dark-field PS-OCT which can avoid the specular reflection problem. Dark-field PS-OCT was implemented by adapting a hybrid method of Bessel-beam illumination and Gaussian-beam detection, and a PS-OCT method based on passive delay unit (PDU). The new system was characterized in comparison with the conventional Gaussian-beam based method in both polarization components and various samples including the human skin. Dark-field PS-OCT performed as good as the conventional PS-OCT without the specular reflection artifact. Dark-field PS-OCT may be useful in practical situations where the specular reflection is unavoidable.
Collapse
|
49
|
Li J, Feroldi F, de Lange J, Daniels JMA, Grünberg K, de Boer JF. Polarization sensitive optical frequency domain imaging system for endobronchial imaging. OPTICS EXPRESS 2015; 23:3390-402. [PMID: 25836196 DOI: 10.1364/oe.23.003390] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A polarization sensitive endoscopic optical frequency domain imaging (PS-OFDI) system with a motorized distal scanning catheter is demonstrated. It employs a passive polarization delay unit to multiplex two orthogonal probing polarization states in depth, and a polarization diverse detection unit to detect interference signal in two orthogonal polarization channels. Per depth location four electro-magnetic field components are measured that can be represented in a complex 2x2 field matrix. A Jones matrix of the sample is derived and the sample birefringence is extracted by eigenvalue decomposition. The condition of balanced detection and the polarization mode dispersion are quantified. A complex field averaging method based on the alignment of randomly pointing field phasors is developed to reduce speckle noise. The variation of the polarization states incident on the tissue due to the circular scanning and catheter sheath birefringence is investigated. With this system we demonstrated imaging of ex vivo chicken muscle, in vivo pig lung and ex vivo human lung specimens.
Collapse
|
50
|
Abstract
The use of ocular imaging tools to estimate structural and functional damage in glaucoma has become a common clinical practice and a substantial focus of vision research. The evolution of the imaging technologies through increased scanning speed, penetration depth, image registration and development of multimodal devices has the potential to detect the pathology more reliably and in earlier stages. This review is focused on new ocular imaging modalities used for glaucoma diagnosis.
Collapse
Affiliation(s)
- Tigran Kostanyan
- Department of Ophthalmology, UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Gadi Wollstein
- Department of Ophthalmology, UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Joel S Schuman
- Department of Ophthalmology, UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
- Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, PA, USA
| |
Collapse
|