1
|
Song S, Hormel TT, Jia Y. Visible-light optical coherence tomography and its applications. NEUROPHOTONICS 2025; 12:020601. [PMID: 40206421 PMCID: PMC11981582 DOI: 10.1117/1.nph.12.2.020601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2024] [Revised: 03/13/2025] [Accepted: 03/14/2025] [Indexed: 04/11/2025]
Abstract
Visible-light optical coherence tomography (vis-OCT) is an emerging OCT technology that uses visible rather than near-infrared illumination and is useful for pre-clinical and clinical imaging. It provides one-micron level axial resolution and distinct scattering and absorption contrast that enables oximetry but requires additional considerations in system implementation and practical settings. We review the development of vis-OCT and demonstrated applications. We also provide insights into prospects and possible technological improvements that may address current challenges.
Collapse
Affiliation(s)
- Siyu Song
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
- Oregon Health and Science University, Department of Biomedical Engineering, Portland, Oregon, United States
| | - Tristan T. Hormel
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Yali Jia
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
- Oregon Health and Science University, Department of Biomedical Engineering, Portland, Oregon, United States
| |
Collapse
|
2
|
Patil MA, Kompella UB. Noninvasive Monitoring of Choroid-Retina Autofluorescence and Intravitreal Nanoparticle Disposition in Royal College of Surgeon Rats of Different Ages and Retinal Thinning. J Ocul Pharmacol Ther 2020; 36:458-466. [PMID: 32552217 DOI: 10.1089/jop.2020.0028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Purpose: To determine the baseline choroid-retina fluorescence signal in Royal College of Surgeon (RCS) rats of various ages with different degrees of retinal degeneration and assess the persistence of intravitreal nanoparticles. Methods: In RCS rats of age 6, 12, and 20 weeks and Sprague Dawley (SD) rats of age 6 and 20 weeks, baseline eye tissue fluorescence and retinal thickness were recorded noninvasively using fluorophotometry and optical coherence tomography (OCT), respectively. Further, 20-nm carboxylate-modified fluorescent particles were injected intravitreally in the above groups of rats, and the depth-wise fluorescence signal was monitored over 7 days using fluorophotometry and confocal laser scanning ophthalmoscopy (cSLO). Additionally, 200 nm particles of the same material were injected intravitreally into about 7-week-old RCS rats and the fluorescence signal was monitored up to 35 days using fluorophotometry. Results: Reduction in retinal thickness and an increase in choroid-retina and lens baseline fluorescence was observed with increasing age of RCS and SD rats. The 20 nm particles persisted in the vitreous of animals from all age groups for at least 7 days postadministration, irrespective of the differences in retinal thickness. cSLO confirmed nanoparticle persistence in the eye. The fluorescence signal from 200 nm particles persisted for 35 days in the vitreous humor. Conclusions: Choroid-retina and lens autofluorescence monitored using fluorophotometry increase with age. Intravitreally injected nanoparticles can be monitored noninvasively in rats using fluorophotometry and cSLO imaging. Both 20 and 200 nm particles persist in the back of the eye tissues, for several days following intravitreal injection.
Collapse
Affiliation(s)
- Madhoosudan A Patil
- Department of Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Uday B Kompella
- Department of Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.,Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.,Department of Bioengineering, and University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.,Department of Colorado Center for Nanomedicine and Nanosafety, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| |
Collapse
|
3
|
Jiao S. Biomedical optical imaging technology and applications: From basic research toward clinical diagnosis. Exp Biol Med (Maywood) 2020; 245:269-272. [PMID: 32141780 DOI: 10.1177/1535370220909543] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Affiliation(s)
- Shuliang Jiao
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| |
Collapse
|
4
|
Lichtenegger A, Gesperger J, Kiesel B, Muck M, Eugui P, Harper DJ, Salas M, Augustin M, Merkle CW, Hitzenberger CK, Widhalm G, Woehrer A, Baumann B. Revealing brain pathologies with multimodal visible light optical coherence microscopy and fluorescence imaging. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-11. [PMID: 31240898 PMCID: PMC6977170 DOI: 10.1117/1.jbo.24.6.066010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 06/07/2019] [Indexed: 05/28/2023]
Abstract
We present a multimodal visible light optical coherence microscopy (OCM) and fluorescence imaging (FI) setup. Specification and phantom measurements were performed to characterize the system. Two applications in neuroimaging were investigated. First, curcumin-stained brain slices of a mouse model of Alzheimer's disease were examined. Amyloid-beta plaques were identified based on the fluorescence of curcumin, and coregistered morphological images of the brain tissue were provided by the OCM channel. Second, human brain tumor biopsies retrieved intraoperatively were imaged prior to conventional neuropathologic work-up. OCM revealed the three-dimensional structure of the brain parenchyma, and FI added the tumor tissue-specific contrast. Attenuation coefficients computed from the OCM data and the florescence intensity values were analyzed and showed a statistically significant difference for 5-aminolevulinic acid (5-ALA)-positive and -negative brain tissues. OCM findings correlated well with malignant hot spots within brain tumor biopsies upon histopathology. The combination of OCM and FI seems to be a promising optical imaging modality providing complementary contrast for applications in the field of neuroimaging.
Collapse
Affiliation(s)
- Antonia Lichtenegger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Johanna Gesperger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- General Hospital and Medical University of Vienna, Institute of Neurology, Vienna, Austria
| | - Barbara Kiesel
- General Hospital and Medical University of Vienna, Univ. Klinik Neurochirurgie, Vienna, Austria
| | - Martina Muck
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- General Hospital and Medical University of Vienna, Institute of Neurology, Vienna, Austria
| | - Pablo Eugui
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Danielle J. Harper
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Matthias Salas
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Marco Augustin
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Conrad W. Merkle
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Christoph K. Hitzenberger
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Georg Widhalm
- General Hospital and Medical University of Vienna, Univ. Klinik Neurochirurgie, Vienna, Austria
| | - Adelheid Woehrer
- General Hospital and Medical University of Vienna, Institute of Neurology, Vienna, Austria
| | - Bernhard Baumann
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| |
Collapse
|
5
|
Dadkhah A, Zhou J, Yeasmin N, Jiao S. Integrated multimodal photoacoustic microscopy with OCT- guided dynamic focusing. BIOMEDICAL OPTICS EXPRESS 2019; 10:137-150. [PMID: 30775089 PMCID: PMC6363202 DOI: 10.1364/boe.10.000137] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 11/27/2018] [Accepted: 11/27/2018] [Indexed: 05/10/2023]
Abstract
Combining different contrast mechanisms to achieve simultaneous multimodal imaging is always desirable but is challenging due to the various optical and hardware requirements for different imaging systems. We developed a multimodal microscopic optical imaging system with the capability of providing comprehensive structural, functional and molecular information of living tissues. This imaging system integrated photoacoustic microscopy (PAM), optical coherence tomography (OCT), optical Doppler tomography (ODT) and confocal fluorescence microscopy in one platform. By taking advantage of the depth resolving capability of OCT, we developed a novel OCT-guided surface contour scanning methodology for dynamic focusing adjustment. We have conducted phantom, in vivo, and ex vivo tests to demonstrate the capability of the multimodal imaging system for providing comprehensive microscopic information of biological tissues. Integrating all the aforementioned imaging modalities with OCT-guided dynamic focusing for simultaneous multimodal imaging has promising potential for preclinical research and clinical practice in the future.
Collapse
Affiliation(s)
- Arash Dadkhah
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| | - Jun Zhou
- School of Physics and Information Engineering, Jianghan University, Wuhan, Hubei 430056, China
| | - Nusrat Yeasmin
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| | - Shuliang Jiao
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| |
Collapse
|
6
|
Nafar Z, Wen R, Jiao S. Visible-light optical coherence tomography-based multimodal system for quantitative fundus autofluorescence imaging. Exp Biol Med (Maywood) 2018; 243:1265-1274. [PMID: 30472882 PMCID: PMC6348593 DOI: 10.1177/1535370218813529] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
IMPACT STATEMENT Quantitative fundus autofluorescence imaging with simultaneous visible-light optical coherence tomography-based multimodal technology has potential significant impact on the diagnosis and monitoring the progression of retinal diseases.
Collapse
Affiliation(s)
- Zahra Nafar
- Department of Biomedical Engineering, Florida International
University, Miami, FL 33174, USA
| | - Rong Wen
- Bascom Palmer Eye Institute, University of Miami Miller School
of Medicine, Miami, FL 33136, USA
| | - Shuliang Jiao
- Department of Biomedical Engineering, Florida International
University, Miami, FL 33174, USA
| |
Collapse
|
7
|
Nafar Z, Wen R, Jiao S. Visible light OCT-based quantitative imaging of lipofuscin in the retinal pigment epithelium with standard reference targets. BIOMEDICAL OPTICS EXPRESS 2018; 9:3768-3782. [PMID: 30338154 PMCID: PMC6191616 DOI: 10.1364/boe.9.003768] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 07/16/2018] [Accepted: 07/16/2018] [Indexed: 05/24/2023]
Abstract
We developed a technology for quantitative retinal autofluorescence (AF, or FAF for fundus AF) imaging for quantifying lipofuscin in the retinal pigment epithelium (RPE). The technology is based on simultaneous visible light optical coherence tomography (VIS-OCT) and AF imaging of the retina and a pair of reference standard targets at the intermediate retinal imaging plane with known reflectivity for the OCT and fluorescence efficiency for the FAF. The technology is able to eliminate the pre-RPE attenuation in FAF imaging by using the simultaneously acquired VIS-OCT image. With the OCT and fluorescence images of the reference targets, the effects of illumination power and detector sensitivity can be eliminated.
Collapse
Affiliation(s)
- Zahra Nafar
- Department of Biomedical Engineering, Florida International University, 10555 W Flagler St, Miami, FL 33174, USA
| | - Rong Wen
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, 1638 NW 10 Ave, Miami, FL 33136, USA
| | - Shuliang Jiao
- Department of Biomedical Engineering, Florida International University, 10555 W Flagler St, Miami, FL 33174, USA
| |
Collapse
|
8
|
Le Marois A, Suhling K. Quantitative Live Cell FLIM Imaging in Three Dimensions. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1035:31-48. [PMID: 29080129 DOI: 10.1007/978-3-319-67358-5_3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
In this chapter, the concept of fluorescence lifetime and its utility in quantitative live cell imaging will be introduced, along with methods to record and analyze FLIM data. Relevant applications in 3D tissue and live cell imaging, including multiplexed FLIM detection, will also be detailed.
Collapse
Affiliation(s)
- Alix Le Marois
- Department of Physics, King's College London, Strand, London, WC2R 2LS, UK
| | - Klaus Suhling
- Department of Physics, King's College London, Strand, London, WC2R 2LS, UK.
| |
Collapse
|
9
|
Shu X, Beckmann L, Zhang HF. Visible-light optical coherence tomography: a review. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-14. [PMID: 29218923 PMCID: PMC5745673 DOI: 10.1117/1.jbo.22.12.121707] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Accepted: 11/13/2017] [Indexed: 05/03/2023]
Abstract
Visible-light optical coherence tomography (vis-OCT) is an emerging imaging modality, providing new capabilities in both anatomical and functional imaging of biological tissue. It relies on visible light illumination, whereas most commercial and investigational OCTs use near-infrared light. As a result, vis-OCT requires different considerations in engineering design and implementation but brings unique potential benefits to both fundamental research and clinical care of several diseases. Here, we intend to provide a summary of the development of vis-OCT and its demonstrated applications. We also provide perspectives on future technology improvement and applications.
Collapse
Affiliation(s)
- Xiao Shu
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
| | - Lisa Beckmann
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
| | - Hao F. Zhang
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
- Northwestern University, Department of Ophthalmology, Chicago, Illinois, United States
- Address all correspondence to: Hao F. Zhang, E-mail:
| |
Collapse
|
10
|
Nafar Z, Jiang M, Wen R, Jiao S. Visible-light optical coherence tomography-based multimodal retinal imaging for improvement of fluorescent intensity quantification. BIOMEDICAL OPTICS EXPRESS 2016; 7:3220-3229. [PMID: 27699094 PMCID: PMC5030006 DOI: 10.1364/boe.7.003220] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 07/31/2016] [Accepted: 07/31/2016] [Indexed: 05/03/2023]
Abstract
We developed a spectral-domain visible-light optical coherence tomography (VIS-OCT) based multimodal imaging technique which can accomplish simultaneous OCT and fluorescence imaging with a single broadband light source. Phantom experiments showed that by using the simultaneously acquired OCT images as a reference, the effect of light attenuation on the intensity of the fluorescent images by materials in front of the fluorescent target can be compensated. This capability of the multimodal imaging technique is of high importance for achieving quantification of the true intensities of autofluorescence (AF) imaging of the retina. We applied the technique in retinal imaging including AF imaging of the retinal pigment epithelium and fluorescein angiography (FA). We successfully demonstrated the effect of compensation on AF and FA images with the simultaneously acquired VIS-OCT images.
Collapse
Affiliation(s)
- Zahra Nafar
- Department of Biomedical Engineering, Florida International University, 10555 W Flagler ST, EC-2610, Miami, FL 33174, USA
| | - Minshan Jiang
- Department of Biomedical Engineering, Florida International University, 10555 W Flagler ST, EC-2610, Miami, FL 33174, USA
| | - Rong Wen
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, 1638 NW 10 Ave, Miami, FL 33136, USA
| | - Shuliang Jiao
- Department of Biomedical Engineering, Florida International University, 10555 W Flagler ST, EC-2610, Miami, FL 33174, USA
| |
Collapse
|
11
|
Method for single illumination source combined optical coherence tomography and fluorescence imaging of fluorescently labeled ocular structures in transgenic mice. Exp Eye Res 2016; 151:68-74. [PMID: 27519152 DOI: 10.1016/j.exer.2016.08.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Revised: 08/05/2016] [Accepted: 08/08/2016] [Indexed: 11/22/2022]
Abstract
In vivo imaging permits longitudinal study of ocular disease processes in the same animal over time. Two different in vivo optical imaging modalities - optical coherence tomography (OCT) and fluorescence - provide important structural and cellular data respectively about disease processes. In this Methods in Eye Research article, we describe and demonstrate the combination of these two modalities producing a truly simultaneous OCT and fluorescence imaging system for imaging of fluorescently labeled animal models. This system uses only a single light source to illuminate both modalities, and both share the same field of view. This allows simultaneous acquisition of OCT and fluorescence images, and the benefits of both techniques are realized without incurring increased costs in variability, light exposure, time, and post-processing effort as would occur when the modalities are used separately. We then utilized this system to demonstrate multi-modal imaging in a progression of samples exhibiting both fluorescence and OCT scattering beginning with resolution targets, ex vivo thy1-YFP labeled neurons in mouse eyes, and finally an in vivo longitudinal time course of GFP labeled myeloid cells in a mouse model of ocular allergy.
Collapse
|
12
|
Kolenderska SM, Wilczyński G, Wojtkowski M. Blue-light Fourier-domain optical-coherence microscopy with linear k-sampling using second-harmonic generation. OPTICS LETTERS 2015; 40:3540-3. [PMID: 26258352 DOI: 10.1364/ol.40.003540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
We demonstrate Fourier-domain optical-coherence microscopy (OCM) method that uses blue light for high-resolution microscopic imaging. Spectrally broad bandwidth is obtained by means of second-harmonic generation of Ti:sapphire laser light on the nonlinear crystal. Angular scanning of the crystal performed by a resonant scanner results in second-harmonic generation for a broad range of frequencies producing blue light with central wavelength of 402 nm and bandwidth of 35 nm in one cycle. The axial resolution of the new setup is 3.5 μm in air, and the transverse resolution for Olympus 40× objective lens is 2.7 μm in X direction and 3.2 μm in Y direction. The developed technique enables registering spectral interferometric signal directly in k domain. Additionally, we present examples of imaging a biological specimen using the newly developed method.
Collapse
|