1
|
Stolze G, Kakkassery V, Kowerko D, Bartos M, Hoffmann K, Sedlmayr M, Engelmann K. [MiHUBx: a digital progress hub for the use of intersectoral clinical data sets using the example of diabetic macular edema]. DIE OPHTHALMOLOGIE 2025; 122:262-269. [PMID: 39692888 DOI: 10.1007/s00347-024-02146-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Revised: 11/04/2024] [Accepted: 11/12/2024] [Indexed: 12/19/2024]
Abstract
BACKGROUND Evidence-based treatment recommendations are helpful in the corresponding discipline-specific treatment but can hardly take data from real-world care into account. In order to make better use of this in everyday clinical practice, including with respect to predictive statements about disease development or treatment success, models with data from treatment must be developed in order to use them for the development of assistive artificial intelligence. GOAL The aim of the Use Case 1 of the medical informatics hub in Saxony (MiHUBx) is the development of a model based on treatment and research data for a treatment algorithm supported by biomarkers and also the development of the necessary digital infrastructure. MATERIAL AND METHODS Step by step, the necessary partners in hospitals and practices will be brought together technically or through research questions within Use Case 1 "Ophthalmology meets Diabetology", a regional digital progress hub in health, the medical informatics hub in Saxony (MiHUBx ) of the nationwide medical informatics initiative (MII). RESULTS Based on joint studies with diabetologists, robust serological and imaging biomarkers were selected that provide evidence of the development of diabetic macular edema (DME). In the future, these and other scientifically proven prognostic markers will be incorporated into a treatment algorithm that is supported by artificial intelligence (AI). For this purpose, model procedures are being developed together with medical informatics specialists. At the same time, a data integration center (DIZ) was established. CONCLUSION In addition to the structured and technical combination of the previously disseminated and partially heterogeneous treatment data, the Use Case 1 defines the chances and hurdles for using such real-world data to develop artificial intelligence.
Collapse
Affiliation(s)
- Gabriel Stolze
- Klinik für Augenheilkunde, Klinikum Chemnitz gGmbH, Flemmingstraße 2, 09116, Chemnitz, Deutschland.
| | - Vinodh Kakkassery
- Klinik für Augenheilkunde, Klinikum Chemnitz gGmbH, Flemmingstraße 2, 09116, Chemnitz, Deutschland
| | - Danny Kowerko
- Fakultät für Informatik, Juniorprofessur Media Computing, Technische Universität Chemnitz, Straße der Nationen 62, 09111, Chemnitz, Deutschland
| | - Martin Bartos
- Bereich Informatik, Klinikum Chemnitz gGmbH, Flemmingstraße 2, 09116, Chemnitz, Deutschland
| | - Katja Hoffmann
- Institut für Medizinische Informatik und Biometrie, Medizinische Fakultät Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 4, 01307, Dresden, Deutschland
| | - Martin Sedlmayr
- Institut für Medizinische Informatik und Biometrie, Medizinische Fakultät Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 4, 01307, Dresden, Deutschland
| | - Katrin Engelmann
- Klinik für Augenheilkunde, Klinikum Chemnitz gGmbH, Flemmingstraße 2, 09116, Chemnitz, Deutschland
| |
Collapse
|
2
|
Nawaz M, Uvaliyev A, Bibi K, Wei H, Abaxi SMD, Masood A, Shi P, Ho HP, Yuan W. Unraveling the complexity of Optical Coherence Tomography image segmentation using machine and deep learning techniques: A review. Comput Med Imaging Graph 2023; 108:102269. [PMID: 37487362 DOI: 10.1016/j.compmedimag.2023.102269] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 06/30/2023] [Accepted: 07/03/2023] [Indexed: 07/26/2023]
Abstract
Optical Coherence Tomography (OCT) is an emerging technology that provides three-dimensional images of the microanatomy of biological tissue in-vivo and at micrometer-scale resolution. OCT imaging has been widely used to diagnose and manage various medical diseases, such as macular degeneration, glaucoma, and coronary artery disease. Despite its wide range of applications, the segmentation of OCT images remains difficult due to the complexity of tissue structures and the presence of artifacts. In recent years, different approaches have been used for OCT image segmentation, such as intensity-based, region-based, and deep learning-based methods. This paper reviews the major advances in state-of-the-art OCT image segmentation techniques. It provides an overview of the advantages and limitations of each method and presents the most relevant research works related to OCT image segmentation. It also provides an overview of existing datasets and discusses potential clinical applications. Additionally, this review gives an in-depth analysis of machine learning and deep learning approaches for OCT image segmentation. It outlines challenges and opportunities for further research in this field.
Collapse
Affiliation(s)
- Mehmood Nawaz
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Adilet Uvaliyev
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Khadija Bibi
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Hao Wei
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Sai Mu Dalike Abaxi
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Anum Masood
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Peilun Shi
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Ho-Pui Ho
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China
| | - Wu Yuan
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong Special Administrative Region of China.
| |
Collapse
|
3
|
Xie H, Xu W, Wang YX, Wu X. Deep learning network with differentiable dynamic programming for retina OCT surface segmentation. BIOMEDICAL OPTICS EXPRESS 2023; 14:3190-3202. [PMID: 37497505 PMCID: PMC10368040 DOI: 10.1364/boe.492670] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/19/2023] [Accepted: 05/23/2023] [Indexed: 07/28/2023]
Abstract
Multiple-surface segmentation in optical coherence tomography (OCT) images is a challenging problem, further complicated by the frequent presence of weak image boundaries. Recently, many deep learning-based methods have been developed for this task and yield remarkable performance. Unfortunately, due to the scarcity of training data in medical imaging, it is challenging for deep learning networks to learn the global structure of the target surfaces, including surface smoothness. To bridge this gap, this study proposes to seamlessly unify a U-Net for feature learning with a constrained differentiable dynamic programming module to achieve end-to-end learning for retina OCT surface segmentation to explicitly enforce surface smoothness. It effectively utilizes the feedback from the downstream model optimization module to guide feature learning, yielding better enforcement of global structures of the target surfaces. Experiments on Duke AMD (age-related macular degeneration) and JHU MS (multiple sclerosis) OCT data sets for retinal layer segmentation demonstrated that the proposed method was able to achieve subvoxel accuracy on both datasets, with the mean absolute surface distance (MASD) errors of 1.88 ± 1.96μm and 2.75 ± 0.94μm, respectively, over all the segmented surfaces.
Collapse
Affiliation(s)
- Hui Xie
- Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, IA, USA
| | - Weiyu Xu
- Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, IA, USA
| | - Ya Xing Wang
- Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital University of Medical Science, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China
| | - Xiaodong Wu
- Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, IA, USA
| |
Collapse
|
4
|
Zhang H, Yang J, Zheng C, Zhao S, Zhang A. Annotation-efficient learning for OCT segmentation. BIOMEDICAL OPTICS EXPRESS 2023; 14:3294-3307. [PMID: 37497504 PMCID: PMC10368022 DOI: 10.1364/boe.486276] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 04/29/2023] [Accepted: 05/26/2023] [Indexed: 07/28/2023]
Abstract
Deep learning has been successfully applied to OCT segmentation. However, for data from different manufacturers and imaging protocols, and for different regions of interest (ROIs), it requires laborious and time-consuming data annotation and training, which is undesirable in many scenarios, such as surgical navigation and multi-center clinical trials. Here we propose an annotation-efficient learning method for OCT segmentation that could significantly reduce annotation costs. Leveraging self-supervised generative learning, we train a Transformer-based model to learn the OCT imagery. Then we connect the trained Transformer-based encoder to a CNN-based decoder, to learn the dense pixel-wise prediction in OCT segmentation. These training phases use open-access data and thus incur no annotation costs, and the pre-trained model can be adapted to different data and ROIs without re-training. Based on the greedy approximation for the k-center problem, we also introduce an algorithm for the selective annotation of the target data. We verified our method on publicly-available and private OCT datasets. Compared to the widely-used U-Net model with 100% training data, our method only requires ∼10% of the data for achieving the same segmentation accuracy, and it speeds the training up to ∼3.5 times. Furthermore, our proposed method outperforms other potential strategies that could improve annotation efficiency. We think this emphasis on learning efficiency may help improve the intelligence and application penetration of OCT-based technologies.
Collapse
Affiliation(s)
- Haoran Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianlong Yang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ce Zheng
- Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Shiqing Zhao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Aili Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
5
|
Marques R, Andrade De Jesus D, Barbosa-Breda J, Van Eijgen J, Stalmans I, van Walsum T, Klein S, G Vaz P, Sánchez Brea L. Automatic Segmentation of the Optic Nerve Head Region in Optical Coherence Tomography: A Methodological Review. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 220:106801. [PMID: 35429812 DOI: 10.1016/j.cmpb.2022.106801] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 03/07/2022] [Accepted: 04/01/2022] [Indexed: 06/14/2023]
Abstract
The optic nerve head (ONH) represents the intraocular section of the optic nerve, which is prone to damage by intraocular pressure (IOP). The advent of optical coherence tomography (OCT) has enabled the evaluation of novel ONH parameters, namely the depth and curvature of the lamina cribrosa (LC). Together with the Bruch's membrane minimum-rim-width (BMO-MRW), these seem to be promising ONH parameters for diagnosis and monitoring of retinal diseases such as glaucoma. Nonetheless, these OCT derived biomarkers are mostly extracted through manual segmentation, which is time-consuming and prone to bias, thus limiting their usability in clinical practice. The automatic segmentation of ONH in OCT scans could further improve the current clinical management of glaucoma and other diseases. This review summarizes the current state-of-the-art in automatic segmentation of the ONH in OCT. PubMed and Scopus were used to perform a systematic review. Additional works from other databases (IEEE, Google Scholar and ARVO IOVS) were also included, resulting in a total of 29 reviewed studies. For each algorithm, the methods, the size and type of dataset used for validation, and the respective results were carefully analysed. The results show a lack of consensus regarding the definition of segmented regions, extracted parameters and validation approaches, highlighting the importance and need of standardized methodologies for ONH segmentation. Only with a concrete set of guidelines, these automatic segmentation algorithms will build trust in data-driven segmentation models and be able to enter clinical practice.
Collapse
Affiliation(s)
- Rita Marques
- Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics (LIBPhys-UC), Department of Physics, University of Coimbra, Coimbra, Portugal; Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands
| | - Danilo Andrade De Jesus
- Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands.
| | - João Barbosa-Breda
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium; Cardiovascular R&D Center, Faculty of Medicine of the University of Porto, Porto, Portugal; Ophthalmology Department, São João Universitary Hospital Center, Porto, Portugal
| | - Jan Van Eijgen
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium; Department of Ophthalmology, University Hospitals UZ Leuven, Leuven, Belgium
| | - Ingeborg Stalmans
- Research Group Ophthalmology, Department of Neurosciences, KU Leuven, Leuven, Belgium; Department of Ophthalmology, University Hospitals UZ Leuven, Leuven, Belgium
| | - Theo van Walsum
- Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands
| | - Stefan Klein
- Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands
| | - Pedro G Vaz
- Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics (LIBPhys-UC), Department of Physics, University of Coimbra, Coimbra, Portugal
| | - Luisa Sánchez Brea
- Biomedical Imaging Group Rotterdam, Department of Radiology & Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands
| |
Collapse
|
6
|
Xie H, Pan Z, Zhou L, Zaman FA, Chen DZ, Jonas JB, Xu W, Wang YX, Wu X. Globally optimal OCT surface segmentation using a constrained IPM optimization. OPTICS EXPRESS 2022; 30:2453-2471. [PMID: 35209385 DOI: 10.1364/oe.444369] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 01/01/2022] [Indexed: 06/14/2023]
Abstract
Segmentation of multiple surfaces in optical coherence tomography (OCT) images is a challenging problem, further complicated by the frequent presence of weak boundaries, varying layer thicknesses, and mutual influence between adjacent surfaces. The traditional graph-based optimal surface segmentation method has proven its effectiveness with its ability to capture various surface priors in a uniform graph model. However, its efficacy heavily relies on handcrafted features that are used to define the surface cost for the "goodness" of a surface. Recently, deep learning (DL) is emerging as a powerful tool for medical image segmentation thanks to its superior feature learning capability. Unfortunately, due to the scarcity of training data in medical imaging, it is nontrivial for DL networks to implicitly learn the global structure of the target surfaces, including surface interactions. This study proposes to parameterize the surface cost functions in the graph model and leverage DL to learn those parameters. The multiple optimal surfaces are then simultaneously detected by minimizing the total surface cost while explicitly enforcing the mutual surface interaction constraints. The optimization problem is solved by the primal-dual interior-point method (IPM), which can be implemented by a layer of neural networks, enabling efficient end-to-end training of the whole network. Experiments on spectral-domain optical coherence tomography (SD-OCT) retinal layer segmentation demonstrated promising segmentation results with sub-pixel accuracy.
Collapse
|
7
|
Automatic Identification and Intuitive Map Representation of the Epiretinal Membrane Presence in 3D OCT Volumes. SENSORS 2019; 19:s19235269. [PMID: 31795480 PMCID: PMC6929067 DOI: 10.3390/s19235269] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 11/26/2019] [Accepted: 11/27/2019] [Indexed: 01/27/2023]
Abstract
Optical Coherence Tomography (OCT) is a medical image modality providing high-resolution cross-sectional visualizations of the retinal tissues without any invasive procedure, commonly used in the analysis of retinal diseases such as diabetic retinopathy or retinal detachment. Early identification of the epiretinal membrane (ERM) facilitates ERM surgical removal operations. Moreover, presence of the ERM is linked to other retinal pathologies, such as macular edemas, being among the main causes of vision loss. In this work, we propose an automatic method for the characterization and visualization of the ERM's presence using 3D OCT volumes. A set of 452 features is refined using the Spatial Uniform ReliefF (SURF) selection strategy to identify the most relevant ones. Afterwards, a set of representative classifiers is trained, selecting the most proficient model, generating a 2D reconstruction of the ERM's presence. Finally, a post-processing stage using a set of morphological operators is performed to improve the quality of the generated maps. To verify the proposed methodology, we used 20 3D OCT volumes, both with and without the ERM's presence, totalling 2428 OCT images manually labeled by a specialist. The most optimal classifier in the training stage achieved a mean accuracy of 91 . 9 % . Regarding the post-processing stage, mean specificity values of 91 . 9 % and 99 . 0 % were obtained from volumes with and without the ERM's presence, respectively.
Collapse
|
8
|
Baamonde S, de Moura J, Novo J, Charlón P, Ortega M. Automatic identification and characterization of the epiretinal membrane in OCT images. BIOMEDICAL OPTICS EXPRESS 2019; 10:4018-4033. [PMID: 31452992 PMCID: PMC6701536 DOI: 10.1364/boe.10.004018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 06/05/2019] [Accepted: 06/09/2019] [Indexed: 05/16/2023]
Abstract
Optical coherence tomography (OCT) is a medical image modality that is used to capture, non-invasively, high-resolution cross-sectional images of the retinal tissue. These images constitute a suitable scenario for the diagnosis of relevant eye diseases like the vitreomacular traction or the diabetic retinopathy. The identification of the epiretinal membrane (ERM) is a relevant issue as its presence constitutes a symptom of diseases like the macular edema, deteriorating the vision quality of the patients. This work presents an automatic methodology for the identification of the ERM presence in OCT scans. Initially, a complete and heterogeneous set of features was defined to capture the properties of the ERM in the OCT scans. Selected features went through a feature selection process to further improve the method efficiency. Additionally, representative classifiers were trained and tested to measure the suitability of the proposed approach. The method was tested with a dataset of 285 OCT scans labeled by a specialist. In particular, 3,600 samples were equally extracted from the dataset, representing zones with and without ERM presence. Different experiments were conducted to reach the most suitable approach. Finally, selected classifiers were trained and compared using different metrics, providing in the best configuration an accuracy of 89.35%.
Collapse
Affiliation(s)
- Sergio Baamonde
- Department of Computer Science, University of A Coruña, 15071 A Coruña, Spain
- CITIC-Research Center of Information and Communication Technologies, University of A Coruña, 15071 A Coruña, Spain
| | - Joaquim de Moura
- Department of Computer Science, University of A Coruña, 15071 A Coruña, Spain
- CITIC-Research Center of Information and Communication Technologies, University of A Coruña, 15071 A Coruña, Spain
| | - Jorge Novo
- Department of Computer Science, University of A Coruña, 15071 A Coruña, Spain
- CITIC-Research Center of Information and Communication Technologies, University of A Coruña, 15071 A Coruña, Spain
| | - Pablo Charlón
- Instituto Oftalmológico Victoria de Rojas, A Coruña, Spain
| | - Marcos Ortega
- Department of Computer Science, University of A Coruña, 15071 A Coruña, Spain
- CITIC-Research Center of Information and Communication Technologies, University of A Coruña, 15071 A Coruña, Spain
| |
Collapse
|
9
|
Yadav SK, Kadas EM, Motamedi S, Polthier K, Haußer F, Gawlik K, Paul F, Brandt A. Optic nerve head three-dimensional shape analysis. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-13. [PMID: 30315645 DOI: 10.1117/1.jbo.23.10.106004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 08/06/2018] [Indexed: 06/08/2023]
Abstract
We present a method for optic nerve head (ONH) 3-D shape analysis from retinal optical coherence tomography (OCT). The possibility to noninvasively acquire in vivo high-resolution 3-D volumes of the ONH using spectral domain OCT drives the need to develop tools that quantify the shape of this structure and extract information for clinical applications. The presented method automatically generates a 3-D ONH model and then allows the computation of several 3-D parameters describing the ONH. The method starts with a high-resolution OCT volume scan as input. From this scan, the model-defining inner limiting membrane (ILM) as inner surface and the retinal pigment epithelium as outer surface are segmented, and the Bruch's membrane opening (BMO) as the model origin is detected. Based on the generated ONH model by triangulated 3-D surface reconstruction, different parameters (areas, volumes, annular surface ring, minimum distances) of different ONH regions can then be computed. Additionally, the bending energy (roughness) in the BMO region on the ILM surface and 3-D BMO-MRW surface area are computed. We show that our method is reliable and robust across a large variety of ONH topologies (specific to this structure) and present a first clinical application.
Collapse
Affiliation(s)
- Sunil Kumar Yadav
- Charité - Universitätsmedizin Berlin, NeuroCure Clinical Research Center, Corporate Member of Freie, Germany
- Charité - Universitätsmedizin, Experimental and Clinical Research Center, Max Delbrück Center for Mo, Germany
- Freie Universität Berlin, Mathematical Geometry Processing Group, Berlin, Germany
| | - Ella Maria Kadas
- Charité - Universitätsmedizin Berlin, NeuroCure Clinical Research Center, Corporate Member of Freie, Germany
- Charité - Universitätsmedizin, Experimental and Clinical Research Center, Max Delbrück Center for Mo, Germany
| | - Seyedamirhosein Motamedi
- Charité - Universitätsmedizin Berlin, NeuroCure Clinical Research Center, Corporate Member of Freie, Germany
- Charité - Universitätsmedizin, Experimental and Clinical Research Center, Max Delbrück Center for Mo, Germany
| | - Konrad Polthier
- Freie Universität Berlin, Mathematical Geometry Processing Group, Berlin, Germany
| | - Frank Haußer
- Beuth University of Applied Sciences, Berlin, Germany
| | - Kay Gawlik
- Charité - Universitätsmedizin Berlin, NeuroCure Clinical Research Center, Corporate Member of Freie, Germany
- Charité - Universitätsmedizin, Experimental and Clinical Research Center, Max Delbrück Center for Mo, Germany
- Beuth University of Applied Sciences, Berlin, Germany
| | - Friedemann Paul
- Charité - Universitätsmedizin Berlin, Department of Neurology, Berlin, Germany
| | - Alexander Brandt
- Charité - Universitätsmedizin Berlin, NeuroCure Clinical Research Center, Corporate Member of Freie, Germany
- Charité - Universitätsmedizin, Experimental and Clinical Research Center, Max Delbrück Center for Mo, Germany
| |
Collapse
|