1
|
Lee Y, Zhang HF, Sun C. Highly sensitive ultrasound detection using nanofabricated polymer micro-ring resonators. NANO CONVERGENCE 2023; 10:30. [PMID: 37338745 DOI: 10.1186/s40580-023-00378-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 06/01/2023] [Indexed: 06/21/2023]
Abstract
Photoacoustic (PA) imaging enables noninvasive volumetric imaging of biological tissues by capturing the endogenous optical absorption contrast. Conventional ultrasound detectors using piezoelectric materials have been widely used for transducing ultrasound signals into the electrical signals for PA imaging reconstruction. However, their inherent limitations in detection bandwidth and sensitivity per unit area have unfortunately constrained the performance of PA imaging. Optical based ultrasound detection methods emerge to offer very promising solutions. In particular, polymer micro-ring resonators (MRRs) in the form of integrated photonic circuits (IPC) enable significant reduction for the sensing area to 80 μm in diameter, while maintaining highly sensitive ultrasound detection with noise equivalent pressure (NEP) of 0.49 Pa and a broad detection frequency range up to 250 MHz. The continued engineering innovation has further transformed MRRs to be transparent to the light and thus, opens up a wide range of applications, including multi-modality optical microscope with isometric resolution, PA endoscope, photoacoustic computed tomography (PACT), and more. This review article summarizes and discusses the evolution of polymer MRR design and the associated nanofabrication process for improving the performance of ultrasound detection. The resulting novel imaging applications will also be reviewed and discussed.
Collapse
Affiliation(s)
- Youngseop Lee
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Department of Mechanical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Hao F Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Cheng Sun
- Department of Mechanical Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
2
|
Kim M, Lee KW, Kim K, Gulenko O, Lee C, Keum B, Chun HJ, Choi HS, Kim CU, Yang JM. Intra-instrument channel workable, optical-resolution photoacoustic and ultrasonic mini-probe system for gastrointestinal endoscopy. PHOTOACOUSTICS 2022; 26:100346. [PMID: 35313458 PMCID: PMC8933520 DOI: 10.1016/j.pacs.2022.100346] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 03/08/2022] [Indexed: 05/04/2023]
Abstract
There has been a long-standing expectation that the optical-resolution embodiment of photoacoustic tomography could have a substantial impact on gastrointestinal endoscopy by enabling microscopic visualization of the vasculature based on the endogenous contrast mechanism. Although multiple studies have demonstrated the in vivo imaging capability of a developed imaging device over the last decade, the implementation of such an endoscopic system that can be applied immediately when necessary via the instrument channel of a video endoscope has been a challenge. In this study, we developed a 3.38-mm diameter catheter-based, integrated optical-resolution photoacoustic and ultrasonic mini-probe system and successfully demonstrated its intra-instrument channel workability for the standard 3.7-mm diameter instrument channel of a clinical video endoscope based on a swine model. Through the instrument channel, we acquired the first in vivo dual-mode photoacoustic and ultrasonic endoscopic images from the esophagogastric junction of a swine. Further, in a rat colorectum in vivo imaging experiment, we visualized hierarchically developed mesh-like capillary networks with a hole size as small as ~50 µm, which suggests the potential level of image details that could be photoacoustically provided in clinical settings in the future.
Collapse
Affiliation(s)
- Minjae Kim
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
| | - Kang Won Lee
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
| | - KiSik Kim
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
| | - Oleksandra Gulenko
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
| | - Cheol Lee
- Department of Physics, UNIST, Ulsan 44919, South Korea
| | - Bora Keum
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
| | - Hoon Jai Chun
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
| | - Hyuk Soon Choi
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul 02841, South Korea
- Corresponding authors.
| | - Chae Un Kim
- Department of Physics, UNIST, Ulsan 44919, South Korea
- Corresponding authors.
| | - Joon-Mo Yang
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
- Corresponding authors.
| |
Collapse
|
3
|
Photoacoustic Imaging in Biomedicine and Life Sciences. Life (Basel) 2022; 12:life12040588. [PMID: 35455079 PMCID: PMC9028050 DOI: 10.3390/life12040588] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 02/19/2022] [Indexed: 12/25/2022] Open
Abstract
Photo-acoustic imaging, also known as opto-acoustic imaging, has become a widely popular modality for biomedical applications. This hybrid technique possesses the advantages of high optical contrast and high ultrasonic resolution. Due to the distinct optical absorption properties of tissue compartments and main chromophores, photo-acoustics is able to non-invasively observe structural and functional variations within biological tissues including oxygenation and deoxygenation, blood vessels and spatial melanin distribution. The detection of acoustic waves produced by a pulsed laser source yields a high scaling range, from organ level photo-acoustic tomography to sub-cellular or even molecular imaging. This review discusses significant novel technical solutions utilising photo-acoustics and their applications in the fields of biomedicine and life sciences.
Collapse
|
4
|
Thompson D, Nagel J, Gasteau D, Manohar S. Laser-induced ultrasound transmitters for large-volume ultrasound tomography. PHOTOACOUSTICS 2022; 25:100312. [PMID: 34868873 PMCID: PMC8626690 DOI: 10.1016/j.pacs.2021.100312] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/27/2021] [Accepted: 10/27/2021] [Indexed: 06/13/2023]
Abstract
We present a protocol for the design, fabrication and characterisation of laser-induced ultrasound transmitters with a specific, user-defined frequency response for the purpose of ultrasound tomography of large-volume biomedical samples. Using an analytic solution to the photoacoustic equation and measurements of the optical and acoustic properties of the materials used in the transmitters, we arrive at a required mixture of carbon black and polydimethylsiloxane to achieve the desired frequency response. After an in-depth explanation of the fabrication and characterisation approaches we show the performance of the fabricated transmitter, which has a centre frequency of 0.9 MHz, 200% bandwidth and 45.8 ∘ opening angle, multi-kPa pressures over a large depth range in water.
Collapse
Affiliation(s)
- D. Thompson
- Correspondence to: University of Twente, Technical Medical centre, Enschede, Netherlands.
| | | | | | | |
Collapse
|
5
|
Yang JM, Ghim CM. Photoacoustic Tomography Opening New Paradigms in Biomedical Imaging. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1310:239-341. [PMID: 33834440 DOI: 10.1007/978-981-33-6064-8_11] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
After the emergence of the ultrasound, X-ray CT, PET, and MRI, photoacoustic tomography (PAT) is now in the phase of its exponential growth, with its expected full maturation being another form of mainstream clinical imaging modality. By combining the high contrast benefit of optical imaging and the high-resolution deep imaging capability of ultrasound, PAT can provide unprecedented anatomical image contrasts at clinically relevant depths as well as enable the use of a variety of functional and molecular imaging information, which is not possible with conventional imaging modalities. With these strengths, PAT has achieved numerous breakthroughs in various biomedical applications and also provided new technical platforms that may be able to resolve unmet issues in clinics. In this chapter, we provide an overview of the development of PAT technology for several major biomedical applications and provide an approximate projection of the future of PAT.
Collapse
Affiliation(s)
- Joon-Mo Yang
- Center for Photoacoustic Medical Instruments, Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea.
| | - Cheol-Min Ghim
- Department of Physics, School of Natural Science, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea
| |
Collapse
|
6
|
Thompson D, Gasteau D, Manohar S. Spatially compounded plane wave imaging using a laser-induced ultrasound source. PHOTOACOUSTICS 2020; 18:100154. [PMID: 32071869 PMCID: PMC7013334 DOI: 10.1016/j.pacs.2019.100154] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 09/26/2019] [Accepted: 11/21/2019] [Indexed: 05/26/2023]
Abstract
This work presents spatially compounded plane wave imaging using a laser-induced ultrasound source. The plane wave source consisted of a 30 μm thick film of carbon black-doped PDMS cured on a 100 μm thick polyester substrate and presented a rectangular aperture of 40 × 3 mm. It was placed in front of a linear ultrasound array, passing through the imaging plane allowing overlap of the detection plane and the insonification plane. Illumination was provided by an array of optical fibre bundles placed above the imaging plane, at an angle. We will first present the general imaging set up and instrumentation used, after which details are given on the fabrication of the transmitter itself and on the objects that were imaged. Comparing laser-induced and conventional ultrasound images of wire phantoms shows the point-spread-function to be, in general, slightly better laterally in the conventional case but more homogeneous throughout the imaging plane with the laser-induced source. Imaging of a tissue-mimicking phantom shows a 55% improvement in contrast between a tumour and the background when using laser-induced ultrasound, as compared to the conventional case.
Collapse
Affiliation(s)
- David Thompson
- Biomedical Photonic Imaging, Technical Medical Centre, University of Twente, The Netherlands
| | - Damien Gasteau
- Biomedical Photonic Imaging, Technical Medical Centre, University of Twente, The Netherlands
- Multi-Modality Medical Imaging Group (M3I), Technical Medical Centre, University of Twente, The Netherlands
| | - Srirang Manohar
- Biomedical Photonic Imaging, Technical Medical Centre, University of Twente, The Netherlands
- Multi-Modality Medical Imaging Group (M3I), Technical Medical Centre, University of Twente, The Netherlands
| |
Collapse
|
7
|
Photoacoustic viscoelasticity imaging for the detection of acute hepatitis: a feasibility study. BIOPHYSICS REPORTS 2020. [DOI: 10.1007/s41048-020-00104-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
AbstractBiomechanical assessments are essential for the understanding of physiological states and the characterization of certain tissue pathologies such as liver cirrhosis. In this work, we showed by the photoacoustic viscoelasticity (PAVE) imaging that obvious mechanical change was also observed in the development of the acute hepatitis owing to the hepatocyte enlargement and intracellular fluid increment, indicating that the PAVE technique can be developed as a supplementary method for detecting acute hepatitis in future. The feasibility of the PAVE imaging is validated by a group of agar phantoms. Furthermore, acute hepatitis pathological animal models were established and imaged ex vivo and in situ by the PAVE technique to demonstrate its capability for the mechanical characterization of acute hepatitis, and the imaging results were consistent with pathological results. The feasibility study of detecting acute hepatitis by the PAVE technique proved that this method has potential to be developed as a clinical biomechanical imaging method to supplement current clinical strategy for liver disease detection.
Collapse
|
8
|
Zhou G, Lim ZH, Qi Y, Zhou G. Single-Pixel MEMS Imaging Systems. MICROMACHINES 2020; 11:E219. [PMID: 32093324 PMCID: PMC7074650 DOI: 10.3390/mi11020219] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 02/18/2020] [Accepted: 02/19/2020] [Indexed: 11/16/2022]
Abstract
Single-pixel imaging technology is an attractive technology considering the increasing demand of imagers that can operate in wavelengths where traditional cameras have limited efficiency. Meanwhile, the miniaturization of imaging systems is also desired to build affordable and portable devices for field applications. Therefore, single-pixel imaging systems based on microelectromechanical systems (MEMS) is an effective solution to develop truly miniaturized imagers, owing to their ability to integrate multiple functionalities within a small device. MEMS-based single-pixel imaging systems have mainly been explored in two research directions, namely the encoding-based approach and the scanning-based approach. The scanning method utilizes a variety of MEMS scanners to scan the target scenery and has potential applications in the biological imaging field. The encoding-based system typically employs MEMS modulators and a single-pixel detector to encode the light intensities of the scenery, and the images are constructed by harvesting the power of computational technology. This has the capability to capture non-visible images and 3D images. Thus, this review discusses the two approaches in detail, and their applications are also reviewed to evaluate the efficiency and advantages in various fields.
Collapse
Affiliation(s)
- Guangcan Zhou
- Micro and Nano Systems Initiative, Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore; (G.Z.); (Z.H.L.); (Y.Q.)
| | - Zi Heng Lim
- Micro and Nano Systems Initiative, Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore; (G.Z.); (Z.H.L.); (Y.Q.)
| | - Yi Qi
- Micro and Nano Systems Initiative, Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore; (G.Z.); (Z.H.L.); (Y.Q.)
| | - Guangya Zhou
- Micro and Nano Systems Initiative, Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore; (G.Z.); (Z.H.L.); (Y.Q.)
| |
Collapse
|
9
|
The Excitation of Ultrasound by Laser Radiation in Water Using an Optical Fiber Laser Converter with a 2D Colloidal Crystalline Coating. COATINGS 2019. [DOI: 10.3390/coatings9120857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The technology of applying a colloidal single-layer coating of transparent polystyrene (PS) Ø 1 μm spheres at the tip face of a quartz fiber has been proposed and tested. Such a coating plays, in a light absorbing liquid, the role of a converter of pulsed laser radiation into acoustic radiation. The generation of ultrasound in water using a converter based on a quartz fiber 1 mm in diameter with a 2D colloidal crystalline coating consisted of polystyrene spheres with a diameter of ~1 μm at the fiber end was investigated. When excited by laser radiation (λ = 1.064 µm), coating of polystyrene spheres created in the liquid a laser thermal microstructure with a characteristic size of fractions of ~λ and a maximum temperature up to 10−2 degree at an energy in a short laser pulse of ~0.005 J. This short-lived thermal microstructure generated sound pulses in the liquid in the approximately 0.2–4 MHz range. The results of the experimental study of this effect are reported. The proposed laser radiation converter with colloidal coating of the optical fiber distal tip by a single layer of transparent spheres can be used for the development of new laser microtools for studying, processing of various objects in microsurgery, microstructuring of the surface, spot cleaning and restoration of objects of art and history.
Collapse
|
10
|
Jin H, Zhang R, Liu S, Zheng Z, Zheng Y. A Single Sensor Dual-Modality Photoacoustic Fusion Imaging for Compensation of Light Fluence Variation. IEEE Trans Biomed Eng 2019; 66:1810-1813. [DOI: 10.1109/tbme.2019.2904502] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
11
|
MEMS Actuators for Optical Microendoscopy. MICROMACHINES 2019; 10:mi10020085. [PMID: 30682852 PMCID: PMC6412441 DOI: 10.3390/mi10020085] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/26/2018] [Accepted: 12/28/2018] [Indexed: 01/21/2023]
Abstract
Growing demands for affordable, portable, and reliable optical microendoscopic imaging devices are attracting research institutes and industries to find new manufacturing methods. However, the integration of microscopic components into these subsystems is one of today's challenges in manufacturing and packaging. Together with this kind of miniaturization more and more functional parts have to be accommodated in ever smaller spaces. Therefore, solving this challenge with the use of microelectromechanical systems (MEMS) fabrication technology has opened the promising opportunities in enabling a wide variety of novel optical microendoscopy to be miniaturized. MEMS fabrication technology enables abilities to apply batch fabrication methods with high-precision and to include a wide variety of optical functionalities to the optical components. As a result, MEMS technology has enabled greater accessibility to advance optical microendoscopy technology to provide high-resolution and high-performance imaging matching with traditional table-top microscopy. In this review the latest advancements of MEMS actuators for optical microendoscopy will be discussed in detail.
Collapse
|
12
|
Moradi H, Tang S, Salcudean SE. Toward Intra-Operative Prostate Photoacoustic Imaging: Configuration Evaluation and Implementation Using the da Vinci Research Kit. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:57-68. [PMID: 30010550 DOI: 10.1109/tmi.2018.2855166] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We compare different possible scanning geometries for prostate photoacoustic tomography (PAT) while considering a realistic reconstruction scenario in which the limited view of the prostate and the directivity effect of the transducer are considered. Simulations and experiments confirm that an intra-operative configuration in which the photoacoustic signal is received by a pickup transducer from the anterior surface of the prostate provides the best approach. We propose a PAT acquisition system that includes a da Vinci system controlled by the da Vinci Research Kit, an illumination laser, and an ultrasound machine with parallel data acquisition. The robot maneuvers the pickup transducer to form a cylindrical detection surface around the prostate. The robot is programmed to acquire trajectories in which the transducer face is parallel to and oriented toward a rotational tomography axis, while the laser is fired and PAT data are collected at regular intervals. We present our initial images acquired with this novel system.
Collapse
|
13
|
Lee C, Kim JY, Kim C. Recent Progress on Photoacoustic Imaging Enhanced with Microelectromechanical Systems (MEMS) Technologies. MICROMACHINES 2018; 9:E584. [PMID: 30413091 PMCID: PMC6266184 DOI: 10.3390/mi9110584] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Revised: 11/05/2018] [Accepted: 11/06/2018] [Indexed: 01/01/2023]
Abstract
Photoacoustic imaging (PAI) is a new biomedical imaging technology currently in the spotlight providing a hybrid contrast mechanism and excellent spatial resolution in the biological tissues. It has been extensively studied for preclinical and clinical applications taking advantage of its ability to provide anatomical and functional information of live bodies noninvasively. Recently, microelectromechanical systems (MEMS) technologies, particularly actuators and sensors, have contributed to improving the PAI system performance, further expanding the research fields. This review introduces cutting-edge MEMS technologies for PAI and summarizes the recent advances of scanning mirrors and detectors in MEMS.
Collapse
Affiliation(s)
- Changho Lee
- Department of Nuclear Medicine, Chonnam National University Medical School & Hwasun Hospital, Hwasun 58128, Korea.
| | - Jin Young Kim
- Departments of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Korea.
| | - Chulhong Kim
- Departments of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Korea.
- Departments of Creative IT Engineering and Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 37673, Korea.
| |
Collapse
|
14
|
Qiu Z, Piyawattanamatha W. New Endoscopic Imaging Technology Based on MEMS Sensors and Actuators. MICROMACHINES 2017; 8:mi8070210. [PMID: 30400401 PMCID: PMC6190023 DOI: 10.3390/mi8070210] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2016] [Revised: 03/09/2017] [Accepted: 03/10/2017] [Indexed: 12/14/2022]
Abstract
Over the last decade, optical fiber-based forms of microscopy and endoscopy have extended the realm of applicability for many imaging modalities. Optical fiber-based imaging modalities permit the use of remote illumination sources and enable flexible forms supporting the creation of portable and hand-held imaging instrumentations to interrogate within hollow tissue cavities. A common challenge in the development of such devices is the design and integration of miniaturized optical and mechanical components. Until recently, microelectromechanical systems (MEMS) sensors and actuators have been playing a key role in shaping the miniaturization of these components. This is due to the precision mechanics of MEMS, microfabrication techniques, and optical functionality enabling a wide variety of movable and tunable mirrors, lenses, filters, and other optical structures. Many promising results from MEMS based optical fiber endoscopy have demonstrated great potentials for clinical translation. In this article, reviews of MEMS sensors and actuators for various fiber-optical endoscopy such as fluorescence, optical coherence tomography, confocal, photo-acoustic, and two-photon imaging modalities will be discussed. This advanced MEMS based optical fiber endoscopy can provide cellular and molecular features with deep tissue penetration enabling guided resections and early cancer assessment to better treatment outcomes.
Collapse
Affiliation(s)
- Zhen Qiu
- Department of Radiology, Stanford University, Stanford, CA 94305, USA.
| | - Wibool Piyawattanamatha
- Departments of Biomedical and Electronics Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
| |
Collapse
|
15
|
Shang S, Chen Z, Zhao Y, Yang S, Xing D. Simultaneous imaging of atherosclerotic plaque composition and structure with dual-mode photoacoustic and optical coherence tomography. OPTICS EXPRESS 2017; 25:530-539. [PMID: 28157944 DOI: 10.1364/oe.25.000530] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The composition of plaque is a major determinant of coronary-related clinical syndromes. By combining photoacoustic tomography (PAT) and optical coherence tomography (OCT), the optical absorption and scattering properties of vascular plaque can be revealed and subsequently used to distinguish the plaque composition and structure. The feasibility and capacity of the dual-mode PAT-OCT technique for resolving vascular plaque was first testified by plaque composition mimicking experiment. PAT obtained lipid information due to optical absorption differences, while owing to scattering differences, OCT achieved imaging of collagen. Furthermore, by combining PAT and OCT, the morphological characteristic and scattering difference of normal and lipid-rich plaque in the ex vivo rabbit aorta was distinguished simultaneously. The experiments demonstrated that the combined PAT and OCT technique is a potential feasible method for detecting the composition and structure of lipid core and fibrous cap in atherosclerosis.
Collapse
|
16
|
VanderLaan D, Karpiouk A, Yeager D, Emelianov S. Real-Time Intravascular Ultrasound and Photoacoustic Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:141-149. [PMID: 28092507 PMCID: PMC5985516 DOI: 10.1109/tuffc.2016.2640952] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Combined intravascular ultrasound and intravascular photoacoustic (IVUS/IVPA) imaging is an emerging hybrid modality being explored as a means of improving the characterization of atherosclerotic plaque anatomical and compositional features. While initial demonstrations of the technique have been encouraging, they have been limited by catheter rotation and data acquisition, displaying, and processing rates on the order of several seconds per frame as well as the use of off-line image processing. Herein, we present a complete IVUS/IVPA imaging system and method capable of real-time IVUS/IVPA imaging, with online data acquisition, image processing, and display of both IVUS and IVPA images. The integrated IVUS/IVPA catheter is fully contained within a 1-mm outer diameter torque cable coupled on the proximal end to a custom-designed spindle enabling optical and electrical coupling to system hardware, including a nanosecond-pulsed laser with a controllable pulse repetition frequency capable of greater than 10 kHz, motor and servo drive, a US pulser/receiver, and a 200-MHz digitizer. The system performance is characterized and demonstrated on a vessel-mimicking phantom with an embedded coronary stent intended to provide IVPA contrast within content of an IVUS image.
Collapse
Affiliation(s)
- Donald VanderLaan
- Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta GA 30332, United States
| | - Andrei Karpiouk
- Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta GA 30332, United States
| | - Doug Yeager
- Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta GA 30332, United States
| | - Stanislav Emelianov
- Electrical & Computer Engineering, Georgia Institute of Technology, Atlanta GA 30332, United States
- Corresponding author:
| |
Collapse
|
17
|
Review of Laser-Generated Ultrasound Transmitters and Their Applications to All-Optical Ultrasound Transducers and Imaging. APPLIED SCIENCES-BASEL 2016. [DOI: 10.3390/app7010025] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
18
|
Feng T, Li Q, Zhang C, Xu G, Guo LJ, Yuan J, Wang X. Characterizing cellular morphology by photoacoustic spectrum analysis with an ultra-broadband optical ultrasonic detector. OPTICS EXPRESS 2016; 24:19853-62. [PMID: 27557261 PMCID: PMC5025227 DOI: 10.1364/oe.24.019853] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Revised: 08/15/2016] [Accepted: 08/15/2016] [Indexed: 05/28/2023]
Abstract
Photoacoustic spectrum analysis (PASA) has been demonstrated as a new method for quantitative tissue imaging and characterization. The ability of PASA in evaluating micro-size tissue features was limited by the bandwidth of detectors for photoacoustic (PA) signal acquisition. We improve upon such a limit, and report on developments of PASA facilitated by an optical ultrasonic detector based on micro-ring resonator. The detector's broad and flat frequency response significantly improves the performance of PASA and extents its characterization capability from the tissue level to cellular level. The performance of the system in characterizing cellular level (a few microns) stochastic objects was first shown via a study on size-controlled optically absorbing phantoms. As a further demonstration of PASA's potential clinical application, it was employed to characterize the morphological changes of red blood cells (RBCs) from a biconcave shape to a spherical shape as a result of aging. This work demonstrates that PASA equipped with the micro-ring ultrasonic detectors is an effective technique in characterizing cellular-level micro-features of biological samples.
Collapse
Affiliation(s)
- Ting Feng
- Institute of Acoustics, Tongji University, Shanghai 200092,
China
- Department of Electronic Science and Engineering, Nanjing University, Nanjing, Jiangsu 21000,
China
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109,
USA
- These authors contributed equally to this work
| | - Qiaochu Li
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109,
USA
- These authors contributed equally to this work
| | - Cheng Zhang
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109,
USA
| | - Guan Xu
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109,
USA
| | - L. Jay Guo
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109,
USA
| | - Jie Yuan
- Department of Electronic Science and Engineering, Nanjing University, Nanjing, Jiangsu 21000,
China
| | - Xueding Wang
- Institute of Acoustics, Tongji University, Shanghai 200092,
China
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109,
USA
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109,
USA
| |
Collapse
|
19
|
Pelivanov I, Shtokolov A, Wei CW, O'Donnell M. A 1 kHz A-scan rate pump-probe laser-ultrasound system for robust inspection of composites. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:1696-1703. [PMID: 26415130 DOI: 10.1109/tuffc.2015.007110] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We recently built a fiber-optic laser-ultrasound (LU) scanner for nondestructive evaluation (NDE) of aircraft composites and demonstrated its greatly improved sensitivity and stability compared with current noncontact systems. It is also very attractive in terms of cost, stability to environmental noise and surface roughness, simplicity in adjustment, footprint, and flexibility. A new type of a balanced fiber-optic Sagnac interferometer is a key component of this all-optical LU pump-probe system. Very high A-scan rates can be achieved because no reference arm or stabilization feedback are needed. Here, we demonstrate LU system performance at 1000 A-scans/s combined with a fast 2-D translator operating at a scanning speed of 100 mm/s with a peak acceleration of 10 m/s(2) in both lateral directions to produce parallel B-scans at high rates. The fast scanning strategy is described in detail. The sensitivity of this system, in terms of noise equivalent pressure, was further improved to be only 8.3 dB above the Nyquist thermal noise limit. To our knowledge, this is the best reported sensitivity for a noncontact ultrasonic detector of this dimension used to inspect aircraft composites.
Collapse
|
20
|
Qiu W, Chen Y, Wong CM, Liu B, Dai J, Zheng H. A novel dual-frequency imaging method for intravascular ultrasound applications. ULTRASONICS 2015; 57:31-5. [PMID: 25454093 DOI: 10.1016/j.ultras.2014.10.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Revised: 10/07/2014] [Accepted: 10/08/2014] [Indexed: 05/25/2023]
Abstract
Intravascular ultrasound (IVUS), which is able to delineate internal structures of vessel wall with fine spatial resolution, has greatly enriched the knowledge of coronary atherosclerosis. A novel dual-frequency imaging method is proposed in this paper for intravascular imaging applications. A probe combined two ultrasonic transducer elements with different center frequencies (36 MHz and 78 MHz) is designed and fabricated with PMN-PT single crystal material. It has the ability to balance both imaging depth and resolution, which are important imaging parameters for clinical test. A dual-channel imaging platform is also proposed for real-time imaging, and this platform has been proven to support programmable processing algorithms, flexible imaging control, and raw RF data acquisition for IVUS applications. Testing results show that the -6 dB axial and lateral imaging resolutions of low-frequency ultrasound are 78 and 132 μm, respectively. In terms of high-frequency ultrasound, axial and lateral resolutions are determined to be as high as 34 and 106 μm. In vitro intravascular imaging on healthy swine aorta is conducted to demonstrate the performance of the dual-frequency imaging method for IVUS applications.
Collapse
Affiliation(s)
- Weibao Qiu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yan Chen
- The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen 518057, China; Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Chi-Man Wong
- The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen 518057, China; Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Baoqiang Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Jiyan Dai
- The Hong Kong Polytechnic University Shenzhen Research Institute, Shenzhen 518057, China; Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
| |
Collapse
|
21
|
Wu M, Jansen K, Springeling G, van der Steen AFW, van Soest G. Impact of device geometry on the imaging characteristics of an intravascular photoacoustic catheter. APPLIED OPTICS 2014; 53:8131-9. [PMID: 25607973 DOI: 10.1364/ao.53.008131] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
A basic requirement for intravascular photoacoustic (IVPA) imaging catheters is that the delivery of light lies within the ultrasonic field of view. Size and manufacturing constraints favor probe designs with offset optical and acoustic beams. This noncollinear dual beam arrangement leads to a curved PA point spread function (PSF). In this work, we characterize the three-dimensional shape of the PSF for IVPA imaging in clear and optically scattering media. We show that the product of the two beam profiles can accurately model the measured peak response in clear and scattering media. We discuss the impact of the PSF shape and its relation to probe construction. We test the imaging capability of the catheter on a phantom and a human artery ex vivo.
Collapse
|
22
|
Sheaff C, Ashkenazi S. Characterization of an improved polyimide-etalon all-optical transducer for high-resolution ultrasound imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:1223-1232. [PMID: 24960711 DOI: 10.1117/12.2040230] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
All-optical transduction of ultrasound provides high-frequency (>20 MHz) operation in the absence of electrical noise and distortion that hinders small-scale piezoelectric probes. Although fabrication of an all-optical 2-D array suitable for in vivo imaging remains incomplete, a thin-film structure integrating a polyimide film with a Fabry-Perot (etalon) receiver has been shown to be a viable candidate. We present here incremental improvements in the performance of a polyimide-etalon transducer and demonstrate imaging with an array configuration alternative to our previous study. We first show that a gain of more than 30% in output pressure is achieved when increasing the thickness of a bare polyimide film from 3 to 15 μm. This motivated the choice of polyimide as the etalon medium--a configuration made possible by utilizing a dielectric mirror that transmits wavelengths used for generation of ultrasound (ultraviolet) and reflects those for detection (near infrared). The increased reflectivity of the dielectric mirror resulted in a 2-fold decrease in noise-equivalent pressure to 3.3 kPa over a bandwidth of 47.5 MHz (0.48 Pa/√Hz). The transmit/receive center frequency increased from 37 to 49 MHz with a -6-dB bandwidth of 126%, and a maximum pressure of 213 kPa was produced using a 43 μm UV spot. A 2 x 2 mm synthetic array of 957 transmitters centered on a 1 x 1 mm synthetic array of four receivers was used to image two wire targets. Offline reconstruction indicated lateral resolutions of 70 and 114 μm at depths of 2.4 and 5.8 mm, respectively, with an average axial resolution of 35 μm. Finally, we explore the challenges of imaging in this configuration, which provides the best opportunity for real-time performance pending further development.
Collapse
|
23
|
Pelivanov I, Buma T, Xia J, Wei CW, O’Donnell M. NDT of fiber-reinforced composites with a new fiber-optic pump-probe laser-ultrasound system. PHOTOACOUSTICS 2014; 2:63-74. [PMID: 25302156 PMCID: PMC4182813 DOI: 10.1016/j.pacs.2014.01.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Revised: 01/10/2014] [Accepted: 01/27/2014] [Indexed: 05/19/2023]
Abstract
Laser-ultrasonics is an attractive and powerful tool for the non-destructive testing and evaluation (NDT&E) of composite materials. Current systems for non-contact detection of ultrasound have relatively low sensitivity compared to contact peizotransducers. They are also expensive, difficult to adjust, and strongly influenced by environmental noise. Moreover, laser-ultrasound (LU) systems typically launch only about 50 firings per second, much slower than the kHz level pulse repetition rate of conventional systems. As demonstrated here, most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive, high repetition rate nanosecond fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe beam detector. In particular, a modified fiber-optic balanced Sagnac interferometer is presented as part of a LU pump-probe system for NDT&E of aircraft composites. The performance of the all-optical system is demonstrated for a number of composite samples with different types and locations of inclusions.
Collapse
Affiliation(s)
- Ivan Pelivanov
- Department of Bioengineering, University of Washington, Seattle, WA, USA
- International Laser Center, Moscow State University, Moscow, Russian Federation
- Corresponding author at: Department of Bioengineering, University of Washington, Seattle, WA, USA. Tel.: +1 206 504 6609.
| | | | - Jinjun Xia
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Chen-Wei Wei
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Matthew O’Donnell
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| |
Collapse
|
24
|
Pelivanov I, Buma T, Xia J, Wei CW, O'Donnell M. A new fiber-optic non-contact compact laser-ultrasound scanner for fast non-destructive testing and evaluation of aircraft composites. JOURNAL OF APPLIED PHYSICS 2014; 115:113105. [PMID: 24737921 PMCID: PMC3971821 DOI: 10.1063/1.4868463] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2013] [Accepted: 03/03/2014] [Indexed: 05/20/2023]
Abstract
Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for non-destructive testing and evaluation of aircraft composites. The performance of the LU system is demonstrated on a composite sample with known defects. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed fiber laser delivering nanosecond laser pulses at a repetition rate up to 76 kHz rate with a pulse energy of 0.6 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals at the same point on the composite surface. A- and B-scans obtained with the Sagnac interferometer are compared to those made with a contact wide-band polyvinylidene fluoride transducer.
Collapse
|
25
|
Gerling M, Zhao Y, Nania S, Norberg KJ, Verbeke CS, Englert B, Kuiper RV, Bergström Å, Hassan M, Neesse A, Löhr JM, Heuchel RL. Real-time assessment of tissue hypoxia in vivo with combined photoacoustics and high-frequency ultrasound. Am J Cancer Res 2014; 4:604-13. [PMID: 24723982 PMCID: PMC3982131 DOI: 10.7150/thno.7996] [Citation(s) in RCA: 98] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2013] [Accepted: 02/04/2014] [Indexed: 11/29/2022] Open
Abstract
Purpose: In preclinical cancer studies, non-invasive functional imaging has become an important tool to assess tumor development and therapeutic effects. Tumor hypoxia is closely associated with tumor aggressiveness and is therefore a key parameter to be monitored. Recently, photoacoustic (PA) imaging with inherently co-registered high-frequency ultrasound (US) has reached preclinical applicability, allowing parallel collection of anatomical and functional information. Dual-wavelength PA imaging can be used to quantify tissue oxygen saturation based on the absorbance spectrum differences between hemoglobin and deoxyhemoglobin. Experimental Design: A new bi-modal PA/US system for small animal imaging was employed to test feasibility and reliability of dual-wavelength PA for measuring relative tissue oxygenation. Murine models of pancreatic and colon cancer were imaged, and differences in tissue oxygenation were compared to immunohistochemistry for hypoxia in the corresponding tissue regions. Results: Functional studies proved feasibility and reliability of oxygenation detection in murine tissue in vivo. Tumor models exhibited different levels of hypoxia in localized regions, which positively correlated with immunohistochemical staining for hypoxia. Contrast-enhanced imaging yielded complementary information on tissue perfusion using the same system. Conclusion: Bimodal PA/US imaging can be utilized to reliably detect hypoxic tumor regions in murine tumor models, thus providing the possibility to collect anatomical and functional information on tumor growth and treatment response live in longitudinal preclinical studies.
Collapse
|
26
|
Hsieh BY, Chen SL, Ling T, Guo LJ, Li PC. All-optical scanhead for ultrasound and photoacoustic imaging-Imaging mode switching by dichroic filtering. PHOTOACOUSTICS 2014; 2:39-46. [PMID: 25302154 PMCID: PMC4182828 DOI: 10.1016/j.pacs.2013.12.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Revised: 10/06/2013] [Accepted: 12/22/2013] [Indexed: 05/09/2023]
Abstract
Ultrasound (US) and photoacoustic (PA) multimodality imaging has the advantage of combining good acoustic resolution with high optical contrast. The use of an all-optical scanhead for both imaging modalities can simplify integration of the two systems and miniaturize the imaging scanhead. Herein we propose and demonstrate an all-optical US/PA scanhead using a thin plate for optoacoustic generation in US imaging, a polymer microring resonator for acoustic detection, and a dichroic filter to switch between the two imaging modes by changing the laser wavelength. A synthetic-aperture focusing technique is used to improve the resolution and contrast. Phantom images demonstrate the feasibility of this design, and show that axial and lateral resolutions of 125 μm and 2.52°, respectively, are possible.
Collapse
Affiliation(s)
- Bao-Yu Hsieh
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Sung-Liang Chen
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, USA
| | - Tao Ling
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, USA
| | - L. Jay Guo
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, USA
| | - Pai-Chi Li
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
- Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
- Corresponding author at: Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan. Tel.: +886 233663551; fax: +886 2 83691354.
| |
Collapse
|
27
|
Bouchard R, Sahin O, Emelianov S. Ultrasound-guided photoacoustic imaging: current state and future development. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:450-66. [PMID: 24569250 DOI: 10.1109/tuffc.2014.2930] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Photoacoustic imaging, frequently coregistered with ultrasonic imaging, can provide functional and cellular/molecular information about tissue within the anatomical landmarks of an imaged region. This review details the fundamentals of photoacoustic imaging and its most promising imaging applications. Particular attention is paid to photoacoustic imaging's relationship with ultrasound, focusing on distinct differences and similarities between the two modalities and highlighting the mutual benefit of using both concurrently in certain preclinical and clinical applications. Much like its origins as an imaging modality were intertwined with ultrasonic imaging (namely, its acoustic transducers and hardware), the future of photoacoustic imaging-particularly in the clinical arena-similarly depends on ultrasound and its time-tested ability to provide real-time visualization of soft tissue.
Collapse
|
28
|
Miida Y, Matsuura Y. All-optical photoacoustic imaging system using fiber ultrasound probe and hollow optical fiber bundle. OPTICS EXPRESS 2013; 21:22023-33. [PMID: 24104094 DOI: 10.1364/oe.21.022023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
An all-optical 3D photoacoustic imaging probe that consists of an optical fiber probe for ultrasound detection and a bundle of hollow optical fibers for excitation of photoacoustic waves was developed. The fiber probe for ultrasound is based on a single-mode optical fiber with a thin polymer film attached to the output end surface that works as a Fabry Perot etalon. The input end of the hollow fiber bundle is aligned so that each fiber in the bundle is sequentially excited. A thin and flexible probe can be obtained because the probe system does not have a scanning mechanism at the distal end.
Collapse
|
29
|
Nuster R, Schmitner N, Wurzinger G, Gratt S, Salvenmoser W, Meyer D, Paltauf G. Hybrid photoacoustic and ultrasound section imaging with optical ultrasound detection. JOURNAL OF BIOPHOTONICS 2013; 6:549-559. [PMID: 23650129 DOI: 10.1002/jbio.201200223] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2012] [Revised: 03/27/2013] [Accepted: 04/11/2013] [Indexed: 06/02/2023]
Abstract
A setup is proposed that provides perfectly co-registered photoacoustic (PA) and ultrasound (US) section images. Photoacoustic and ultrasound backscatter signals are generated by laser pulses coming from the same laser system, the latter by absorption of some of the laser energy on an optically absorbing target near the imaged object. By measuring both signals with the same optical detector, which is focused into the selected section by use of a cylindrical acoustic mirror, the information for both images is acquired simultaneously. Co-registered PA and US images are obtained after applying the inverse Radon transform to the data, which are gathered while rotating the object relative to the detector. Phantom experiments demonstrate a resolution of 1.1 mm between the sections of both imaging modalities and a in-plane resolution of about 60 µm and 120 µm for the US and PA modes, respectively. The complementary contrast mechanisms of the two modalities are shown by images of a zebrafish.
Collapse
Affiliation(s)
- Robert Nuster
- Department of Physics, Karl-Franzens University Graz, 8010 Graz, Austria.
| | | | | | | | | | | | | |
Collapse
|
30
|
Chen SL, Xie Z, Guo LJ, Wang X. A fiber-optic system for dual-modality photoacoustic microscopy and confocal fluorescence microscopy using miniature components. PHOTOACOUSTICS 2013; 1:30-35. [PMID: 24466507 PMCID: PMC3899796 DOI: 10.1016/j.pacs.2013.07.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Imaging of the cells and microvasculature simultaneously is beneficial to the study of tumor angiogenesis and microenvironments. We designed and built a fiber-optic based photoacoustic microscopy (PAM) and confocal fluorescence microscopy (CFM) dual-modality imaging system. To explore the feasibility of this all-optical device for future endoscopic applications, a microelectromechanical systems (MEMS) scanner, a miniature objective lens, and a small size optical microring resonator as an acoustic detector were employed trying to meet the requirements of miniaturization. Both the lateral resolutions of PAM and CFM were quantified to be 8.8 μm. Axial resolutions of PAM and CFM were experimentally measured to be 19 μm and 53 μm, respectively. The experiments on ex vivo animal bladder tissues demonstrate the good performance of this system in imaging not only microvasculature but also cellular structure, suggesting that this novel imaging technique holds potential for improved diagnosis and guided treatment of bladder cancer.
Collapse
Affiliation(s)
- Sung-Liang Chen
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, United States
| | - Zhixing Xie
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, United States
- Corresponding author. Tel.: +1 734 8468816.
| | - L. Jay Guo
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI 48109, United States
| | - Xueding Wang
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, United States
- Corresponding author. Tel.: +1 734 6472728.
| |
Collapse
|
31
|
Hajireza P, Krause K, Brett M, Zemp R. Glancing angle deposited nanostructured film Fabry-Perot etalons for optical detection of ultrasound. OPTICS EXPRESS 2013; 21:6391-6400. [PMID: 23482209 DOI: 10.1364/oe.21.006391] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
In this paper a new class of optical Fabry-Perot-based ultrasound detectors using low acoustic impedance glancing angle deposited (GLAD) films is demonstrated. GLAD is a single-step physical vapor-deposition (PVD) technique used to fabricate porous nanostructured thin films. Using titanium dioxide (TiO(2)), a transparent semiconductor with a high refractive index (n = 2.4), the GLAD technique can be employed to fabricate samples with tailored nano-porosity, refractive index periodicities, and high Q-factor reflectance spectra. The average acoustic impedance of the porous films is lower than bulk materials which will improve acoustic coupling, especially for high acoustic frequencies. For this work, two filters with high reflection in the C-band range and high transparency in the visible range (~80%) using GLAD films were fabricated. A 23 µm Parylene C layer was sandwiched between these two GLAD films in order to form a GLAD Fabry Perot Interferometer (GLAD-FPI). A high speed tunable continuous wavelength C-band laser was focused at the FPI and the reflection was measured using a high speed photodiode. The ultrasound pressure modulated the optical thickness of the FPI and hence its reflectivity. The fabricated sensor was tested using a 10 MHz unfocused transducer. The ultrasound transducer was calibrated using a hydrophone. The minimum detectable acoustic pressure was measured as 80 ± 20 Pa and the -3dB bandwidth was measured to be 18 MHz. This ultra-sensitive sensor can be an alternative to piezoelectric ultrasound transducers for any techniques in which ultrasound waves need to be detected including ultrasonic and photoacoustic imaging modalities. We demonstrate our GLAD-FPI for photoacoustic signal detection in optical-resolution photoacoustic microscopy (OR-PAM). To the best of our knowledge, this is the first time that a FPI fabricated using the GLAD method has been used for ultra-sensitive ultrasound detection.
Collapse
Affiliation(s)
- Parsin Hajireza
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 2V4, Canada
| | | | | | | |
Collapse
|
32
|
Subochev P, Katichev A, Morozov A, Orlova A, Kamensky V, Turchin I. Simultaneous photoacoustic and optically mediated ultrasound microscopy: phantom study. OPTICS LETTERS 2012; 37:4606-8. [PMID: 23164853 DOI: 10.1364/ol.37.004606] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
An experimental setup for combined photoacoustic (PA) and optically mediated ultrasound (US) microscopy is presented. A spherically focused 35 MHz polyvinylidene fluoride (PVDF) ultrasonic detector with a numerical aperture of 0.28, a focal distance of 9 mm, and a bandwidth (-6 dB level) of 24 MHz was used to obtain PA and US data with a 3 mm imaging depth. A fiber-optic system was employed to deliver laser excitation pulses from a tunable laser to the studied medium. A single optical pulse was used to form both PA and US A-scans. The probing US pulses were generated thermoelastically due to absorption of backscattered laser radiation by the metalized surface of a PVDF film.
Collapse
Affiliation(s)
- Pavel Subochev
- Institute of Applied Physics, 46 Ul’yanov Street, Nizhny Novgorod 603950, Russia.
| | | | | | | | | | | |
Collapse
|
33
|
Yang JM, Chen R, Favazza C, Yao J, Li C, Hu Z, Zhou Q, Shung KK, Wang LV. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy. OPTICS EXPRESS 2012; 20:23944-23953. [PMID: 23188360 PMCID: PMC3601641 DOI: 10.1364/oe.20.023944] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Revised: 09/15/2012] [Accepted: 09/18/2012] [Indexed: 05/19/2023]
Abstract
We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications.
Collapse
Affiliation(s)
- Joon-Mo Yang
- Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, Missouri 63130,
USA
- These authors contributed equally to this work
| | - Ruimin Chen
- NIH Ultrasonic Transducer Resource Center, Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, University Park, DRB 130, Los Angeles, California 90089,
USA
- These authors contributed equally to this work
| | - Christopher Favazza
- Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, Missouri 63130,
USA
| | - Junjie Yao
- Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, Missouri 63130,
USA
| | - Chiye Li
- Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, Missouri 63130,
USA
| | - Zhilin Hu
- Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, Missouri 63130,
USA
| | - Qifa Zhou
- NIH Ultrasonic Transducer Resource Center, Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, University Park, DRB 130, Los Angeles, California 90089,
USA
| | - K. Kirk Shung
- NIH Ultrasonic Transducer Resource Center, Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, University Park, DRB 130, Los Angeles, California 90089,
USA
| | - Lihong V. Wang
- Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, Missouri 63130,
USA
| |
Collapse
|
34
|
Karpiouk AB, Wang B, Amirian J, Smalling RW, Emelianov SY. Feasibility of in vivo intravascular photoacoustic imaging using integrated ultrasound and photoacoustic imaging catheter. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:96008-1. [PMID: 23085909 PMCID: PMC3434470 DOI: 10.1117/1.jbo.17.9.096008] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Revised: 07/13/2012] [Accepted: 07/31/2012] [Indexed: 05/17/2023]
Abstract
Pilot studies of in vivo combined intravascular ultrasound (IVUS) and intravascular photoacoustic (IVPA) imaging are reported. A recently introduced prototype of an integrated IVUS/IVPA imaging catheter consisting of a single-element ultrasound transducer and a light delivery system based on a single optical fiber was adapted and used for in vivo imaging of a coronary stent deployed in a rabbit's thoracic aorta in the presence of luminal blood. The results suggest that in vivo IVUS/IVPA imaging is feasible using the integrated IVUS/IVPA imaging catheter. The challenges of in vivo combined IVUS/IVPA imaging are discussed, and further improvements on the design of the catheter and the clinical imaging system are proposed.
Collapse
Affiliation(s)
- Andrei B. Karpiouk
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas 78712
| | - Bo Wang
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas 78712
| | - James Amirian
- University of Texas Health Science Center, Division of Cardiology, Houston, Texas 77030
| | - Richard W. Smalling
- University of Texas Health Science Center, Division of Cardiology, Houston, Texas 77030
| | - Stanislav Y. Emelianov
- University of Texas at Austin, Department of Biomedical Engineering, Austin, Texas 78712
| |
Collapse
|