1
|
Borchert M, Braenzel J, Gnewkow R, Lunin L, Sidiropoulos T, Tümmler J, Will I, Noll T, Reichel O, Rohloff D, Erko A, Krist T, von Korff Schmising C, Pfau B, Eisebitt S, Stiel H, Schick D. Versatile tabletop setup for picosecond time-resolved resonant soft-x-ray scattering and spectroscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:063102. [PMID: 37862537 DOI: 10.1063/5.0151613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 05/31/2023] [Indexed: 10/22/2023]
Abstract
We present a laser-driven, bright, and broadband (50 to 1500 eV) soft-x-ray plasma source with <10 ps pulse duration. This source is employed in two complementary, laboratory-scale beamlines for time-resolved, magnetic resonant scattering and spectroscopy, as well as near-edge x-ray absorption fine-structure (NEXAFS) spectroscopy. In both beamlines, dedicated reflection zone plates (RZPs) are used as single optical elements to capture, disperse, and focus the soft x rays, reaching resolving powers up to E/ΔE > 1000, with hybrid RZPs at the NEXAFS beamline retaining a consistent E/ΔE > 500 throughout the full spectral range, allowing for time-efficient data acquisition. We demonstrate the versatility and performance of our setup by a selection of soft-x-ray spectroscopy and scattering experiments, which so far have not been possible on a laboratory scale. Excellent data quality, combined with experimental flexibility, renders our approach a true alternative to large-scale facilities, such as synchrotron-radiation sources and free-electron lasers.
Collapse
Affiliation(s)
- Martin Borchert
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Julia Braenzel
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Richard Gnewkow
- Helmholtz-Zentrum Berlin, 12489 Berlin, Germany
- Technische Universität Berlin, Institut für Optik und Atomare Physik, 10623 Berlin, Germany
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), 10623 Berlin, Germany
| | - Leonid Lunin
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | | | - Johannes Tümmler
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Ingo Will
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Tino Noll
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Oliver Reichel
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Dirk Rohloff
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | | | - Thomas Krist
- NOB Nano Optics Berlin GmbH, 10627 Berlin, Germany
| | | | - Bastian Pfau
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| | - Stefan Eisebitt
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
- Technische Universität Berlin, Institut für Optik und Atomare Physik, 10623 Berlin, Germany
| | - Holger Stiel
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
- Berlin Laboratory for Innovative X-ray Technologies (BLiX), 10623 Berlin, Germany
| | - Daniel Schick
- Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, 12489 Berlin, Germany
| |
Collapse
|
2
|
Reuss T, Nair Lalithambika SS, David C, Döring F, Jooss C, Risch M, Techert S. Advancements in Liquid Jet Technology and X-ray Spectroscopy for Understanding Energy Conversion Materials during Operation. Acc Chem Res 2023; 56:203-214. [PMID: 36636991 PMCID: PMC9910040 DOI: 10.1021/acs.accounts.2c00525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
ConspectusWater splitting is intensively studied for sustainable and effective energy storage in green/alternative energy harvesting-storage-release cycles. In this work, we present our recent developments for combining liquid jet microtechnology with different types of soft X-ray spectroscopy at high-flux X-ray sources, in particular developed for studying the oxygen evolution reaction (OER). We are particularly interested in the development of in situ photon-in/photon-out techniques, such as in situ resonant inelastic X-ray scattering (RIXS) techniques at high-repetition-frequency X-ray sources, pointing toward operando capabilities. The pilot catalytic systems we use are perovskites having the general structure ABO3 with lanthanides or group II elements at the A sites and transition metals at the B sites. Depending on the chemical substitutions of ABO3, their catalytic activity for OER can be tuned by varying the composition.In this work, we present our in situ RIXS studies of the manganese L-edge of perovskites during OER. We have developed various X-ray spectroscopy approaches like transmission zone plate-, reflection zone plate-, and grating-based emission spectroscopy techniques. Combined with tunable incident X-ray energies, we yield complementary information about changing (inverse) X-ray absorption features of the perovskites, allowing us to deduce element- and oxidation-state-specific chemical monitoring of the catalyst. Adding liquid jet technology, we monitor element- and oxidation-state-specific interactions of the catalyst with water adsorbate during OER. By comparing the different technical spectroscopy approaches combined with high-repetition-frequency experiments at synchrotrons and free-electron lasers, we conclude that the combination of liquid jet with low-resolution zone-plate-based X-ray spectroscopy is sufficient for element- and oxidation-state-specific chemical monitoring during OER and easy to handle.For an in-depth study of OER mechanisms, however, including the characterization of catalyst-water adsorbate in terms of their charge transfer properties and especially valence intermediates formed during OER, high-resolution spectroscopy tools based on a combination of liquid jets with gratings bear bigger potential since they allow resolution of otherwise-overlapping X-ray spectroscopy transitions. Common for all of these experimental approaches is the conclusion that without the versatile developments of liquid jets and liquid beam technologies, elaborate experiments such as high-repetition experiments at high-flux X-ray sources (like synchrotrons or free-electron lasers) would hardly be possible. Such experiments allow sample refreshment for every single X-ray shot for repetition frequencies of up to 5 MHz, so that it is possible (a) to study X-ray-radiation-sensitive samples and also (b) to utilize novel types of flux-hungry X-ray spectroscopy tools like photon-in/photon-out X-ray spectroscopy to study the OER.
Collapse
Affiliation(s)
- Torben Reuss
- Deutsches
Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany
| | | | - Christian David
- Paul
Scherrer Institute, Forschungsstrasse 111, 5232 Villigen-PSI, Switzerland
| | - Florian Döring
- Paul
Scherrer Institute, Forschungsstrasse 111, 5232 Villigen-PSI, Switzerland
| | - Christian Jooss
- Institute
of Material Physics, Göttingen University, Friedrich Hund Platz 1, 37077 Göttingen, Germany
| | - Marcel Risch
- Institute
of Material Physics, Göttingen University, Friedrich Hund Platz 1, 37077 Göttingen, Germany
| | - Simone Techert
- Deutsches
Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany,Institute
for X-ray Physics, Göttingen University, Friedrich Hund Platz 1, 37077 Göttingen, Germany,
| |
Collapse
|
3
|
Probst J, Braig C, Langlotz E, Rahneberg I, Kühnel M, Zeschke T, Siewert F, Krist T, Erko A. Conception of diffractive wavefront correction for XUV and soft x-ray spectroscopy. APPLIED OPTICS 2020; 59:2580-2590. [PMID: 32225799 DOI: 10.1364/ao.384782] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 02/03/2020] [Indexed: 06/10/2023]
Abstract
We present a simple and precise method to minimize aberrations of mirror-based, wavelength-dispersive spectrometers for the extreme ultraviolet (XUV) and soft x-ray domain. The concept enables an enhanced resolving power $ E/\Delta E $E/ΔE, in particular, close to the diffraction limit over a spectral band of a few percent around the design energy of the instrument. Our optical element, the "diffractive wavefront corrector" (DWC), is individually shaped to the form and figure error of the mirror profile and might be written directly with a laser on a plane and even strongly curved substrates. Theory and simulations of various configurations, like Hettrick-Underwood or compact, highly efficient all-in-one setups for $ {{\rm TiO}_2} $TiO2 spectroscopy with $ E/\Delta E \mathbin{\lower.3ex\hbox{$\buildrel{\displaystyle{\lt}}\over{\smash{\displaystyle\sim}\vphantom{_x}}$}} 4.5 \times {10^4} $E/ΔE∼x<4.5×104, are addressed, as well as aspects of their experimental realization.
Collapse
|
4
|
Nowak SH, Armenta R, Schwartz CP, Gallo A, Abraham B, Garcia-Esparza AT, Biasin E, Prado A, Maciel A, Zhang D, Day D, Christensen S, Kroll T, Alonso-Mori R, Nordlund D, Weng TC, Sokaras D. A versatile Johansson-type tender x-ray emission spectrometer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:033101. [PMID: 32259983 DOI: 10.1063/1.5121853] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Accepted: 02/13/2020] [Indexed: 05/23/2023]
Abstract
We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6-5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (∼0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (∼30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.
Collapse
Affiliation(s)
- S H Nowak
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - R Armenta
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - C P Schwartz
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A Gallo
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - B Abraham
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A T Garcia-Esparza
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - E Biasin
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A Prado
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A Maciel
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Zhang
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Day
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - S Christensen
- National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA
| | - T Kroll
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - R Alonso-Mori
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Nordlund
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - T-C Weng
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Sokaras
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| |
Collapse
|
5
|
Beye M, Engel RY, Schunck JO, Dziarzhytski S, Brenner G, Miedema PS. Non-linear soft x-ray methods on solids with MUSIX-the multi-dimensional spectroscopy and inelastic x-ray scattering endstation. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2019; 31:014003. [PMID: 30504529 DOI: 10.1088/1361-648x/aaedf3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
With the intense and coherent x-ray pulses available from free-electron lasers, the possibility to transfer non-linear spectroscopic methods from the laser lab to the x-ray world arises. Advantages especially regarding selectivity and thus information content as well as an improvement of signal levels are expected. The use of coherences is especially fruitful and the example of coherent x-ray/optical sum-frequency generation is discussed. However, many non-linear x-ray methods still await discovery, partially due to the necessity for extremely adaptable and versatile instrumentation that can be brought to free-electron lasers for the analysis of the spectral content emitted from the sample into a continuous range of emission angles. Such an instrument (called MUSIX) is being developed and employed at FLASH, the free-electron laser in Hamburg and is described in this contribution together with first results.
Collapse
Affiliation(s)
- M Beye
- Deutsches Elektronen Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany. Physics Department, Universität Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | | | | | | | | | | |
Collapse
|
6
|
Yin Z, Löchel H, Rehanek J, Goy C, Kalinin A, Schottelius A, Trinter F, Miedema P, Jain A, Valerio J, Busse P, Lehmkühler F, Möller J, Grübel G, Madsen A, Viefhaus J, Grisenti RE, Beye M, Erko A, Techert S. X-ray spectroscopy with variable line spacing based on reflection zone plate optics. OPTICS LETTERS 2018; 43:4390-4393. [PMID: 30211872 DOI: 10.1364/ol.43.004390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Accepted: 08/09/2018] [Indexed: 06/08/2023]
Abstract
X-ray spectroscopy is a method, ideally suited for investigating the electronic structure of matter, which has been enabled by the rapid developments in light sources and instruments. The x-ray fluorescence lines of life-relevant elements such as carbon, nitrogen, and oxygen are located in the soft x-ray regime and call for suitable spectrometer devices. In this Letter, we present a high-resolution spectrum of liquid water, recorded with a soft x-ray spectrometer based on a reflection zone plate (RZP) design. The RZP-based spectrometer with meridional variation of line space density from 2953 to 3757 l/mm offers extremely high detection efficiency and, at the same time, medium energy resolution. We can reproduce the well-known splitting of liquid water in the lone pair regime with 10 s acquisition time.
Collapse
|
7
|
Titus CJ, Baker ML, Lee SJ, Cho HM, Doriese WB, Fowler JW, Gaffney K, Gard JD, Hilton GC, Kenney C, Knight J, Li D, Marks R, Minitti MP, Morgan KM, O'Neil GC, Reintsema CD, Schmidt DR, Sokaras D, Swetz DS, Ullom JN, Weng TC, Williams C, Young BA, Irwin KD, Solomon EI, Nordlund D. L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array. J Chem Phys 2017; 147:214201. [PMID: 29221417 PMCID: PMC5720893 DOI: 10.1063/1.5000755] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Accepted: 11/06/2017] [Indexed: 01/21/2023] Open
Abstract
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.
Collapse
Affiliation(s)
- Charles J Titus
- Department of Physics, Stanford University, Stanford, California 94305, USA
| | - Michael L Baker
- Department of Chemistry, Stanford University, Stanford, California 94305, USA
| | - Sang Jun Lee
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Hsiao-Mei Cho
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - William B Doriese
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Joseph W Fowler
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Kelly Gaffney
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Johnathon D Gard
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Gene C Hilton
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Chris Kenney
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Jason Knight
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Dale Li
- SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Ronald Marks
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Michael P Minitti
- Linac Coherent Light Source, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Kelsey M Morgan
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Galen C O'Neil
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Carl D Reintsema
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Daniel R Schmidt
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Dimosthenis Sokaras
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | - Daniel S Swetz
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Joel N Ullom
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| | - Tsu-Chien Weng
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| | | | - Betty A Young
- Department of Physics, Santa Clara University, Santa Clara, California 95053, USA
| | - Kent D Irwin
- Department of Physics, Stanford University, Stanford, California 94305, USA
| | - Edward I Solomon
- Department of Chemistry, Stanford University, Stanford, California 94305, USA
| | - Dennis Nordlund
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, USA
| |
Collapse
|