1
|
Haseeb F, Bourdakos KN, Forsyth E, Setchfield K, Gorman A, Venkateswaran S, Wright AJ, Mahajan S, Bradley M. Development of hydrogel-based standards and phantoms for non-linear imaging at depth. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:126007. [PMID: 38155703 PMCID: PMC10753126 DOI: 10.1117/1.jbo.28.12.126007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 08/23/2023] [Accepted: 08/28/2023] [Indexed: 12/30/2023]
Abstract
Significance Rapid advances in medical imaging technology, particularly the development of optical systems with non-linear imaging modalities, are boosting deep tissue imaging. The development of reliable standards and phantoms is critical for validation and optimization of these cutting-edge imaging techniques. Aim We aim to design and fabricate flexible, multi-layered hydrogel-based optical standards and evaluate advanced optical imaging techniques at depth. Approach Standards were made using a robust double-network hydrogel matrix consisting of agarose and polyacrylamide. The materials generated ranged from single layers to more complex constructs consisting of up to seven layers, with modality-specific markers embedded between the layers. Results These standards proved useful in the determination of the axial scaling factor for light microscopy and allowed for depth evaluation for different imaging modalities (conventional one-photon excitation fluorescence imaging, two-photon excitation fluorescence imaging, second harmonic generation imaging, and coherent anti-Stokes Raman scattering) achieving actual depths of 1550, 1550, 1240, and 1240 μ m , respectively. Once fabricated, the phantoms were found to be stable for many months. Conclusions The ability to image at depth, the phantom's robustness and flexible layered structure, and the ready incorporation of "optical markers" make these ideal depth standards for the validation of a variety of imaging modalities.
Collapse
Affiliation(s)
- Fizza Haseeb
- University of Edinburgh, School of Chemistry, Edinburgh, United Kingdom
| | - Konstantinos N. Bourdakos
- University of Southampton, School of Chemistry, Faculty of Engineering and Physical Sciences, Southampton, United Kingdom
| | - Ewan Forsyth
- University of Edinburgh, School of Chemistry, Edinburgh, United Kingdom
| | - Kerry Setchfield
- University of Nottingham, Faculty of Engineering, Optics and Photonics Research Group, Nottingham, United Kingdom
| | - Alistair Gorman
- University of Edinburgh, School of Engineering, Edinburgh, United Kingdom
| | - Seshasailam Venkateswaran
- University of Southampton, School of Chemistry, Faculty of Engineering and Physical Sciences, Southampton, United Kingdom
| | - Amanda J. Wright
- University of Nottingham, Faculty of Engineering, Optics and Photonics Research Group, Nottingham, United Kingdom
| | - Sumeet Mahajan
- University of Southampton, School of Chemistry, Faculty of Engineering and Physical Sciences, Southampton, United Kingdom
| | - Mark Bradley
- Queen Mary University of London, Precision Healthcare University Research Institute, London, United Kingdom
| |
Collapse
|
2
|
Metz J, Gintoli M, Corbett AD. Fully automated point spread function analysis using PyCalibrate. Biol Open 2023; 12:bio059758. [PMID: 37815435 PMCID: PMC10651089 DOI: 10.1242/bio.059758] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 10/03/2023] [Indexed: 10/11/2023] Open
Abstract
Reproducibility is severely limited if instrument performance is assumed rather than measured. Within optical microscopy, instrument performance is typically measured using sub-resolution fluorescent beads. However, the process is performed infrequently as it is requires time and suitably trained staff to acquire and then process the bead images. Analysis software still requires the manual entry of imaging parameters. Human error from repeatedly typing these parameters can significantly affect the outcome of the analysis, rendering the results less reproducible. To avoid this issue, PyCalibrate has been developed to fully automate the analysis of bead images. PyCalibrate can be accessed either by executing the Python code locally or via a user-friendly web portal to further improve accessibility when moving between locations and machines. PyCalibrate interfaces with the BioFormats library to make it compatible with a wide range of proprietary image formats. In this study, PyCalibrate analysis performance is directly compared with alternative free-access analysis software PSFj, MetroloJ QC and DayBook 3 and is demonstrated to have equivalent performance but without the need for user supervision.
Collapse
Affiliation(s)
| | - Michele Gintoli
- Faculty of Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands
| | - Alexander David Corbett
- Department of Physics and Astronomy, Stocker Road, Exeter, EX4 4QL, UK
- Living Systems Institute, University of Exeter, EX4 4QL, UK
| |
Collapse
|
3
|
Abrams B, Pengo T, Wee TL, Deagle RC, Vuillemin N, Callahan LM, Smith MA, Kubow KE, Girard AM, Rappoport JZ, Bayles CJ, Cameron LA, Cole R, Brown CM. Tissue-Like 3D Standard and Protocols for Microscope Quality Management. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2023; 29:616-634. [PMID: 37749742 PMCID: PMC10617369 DOI: 10.1093/micmic/ozad014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 11/30/2022] [Accepted: 01/24/2023] [Indexed: 09/27/2023]
Abstract
This article outlines a global study conducted by the Association of Biomedical Resource Facilities (ABRF) Light Microscopy Research Group (LMRG). The results present a novel 3D tissue-like biologically relevant standard sample that is affordable and straightforward to prepare. Detailed sample preparation, instrument-specific image acquisition protocols and image analysis methods are presented and made available to the community. The standard consists of sub-resolution and large well characterized relative intensity fluorescence microspheres embedded in a 120 µm thick 3D gel with a refractive index of 1.365. The standard allows the evaluation of several properties as a function of depth. These include the following: 1) microscope resolution with automated analysis of the point-spread function (PSF), 2) automated signal-to-noise ratio analysis, 3) calibration and correction of fluorescence intensity loss, and 4) quantitative relative intensity. Results demonstrate expected refractive index mismatch dependent losses in intensity and resolution with depth, but the relative intensities of different objects at similar depths are maintained. This is a robust standard showing reproducible results across laboratories, microscope manufacturers and objective lens types (e.g., magnification, immersion medium). Thus, these tools will be valuable for the global community to benchmark fluorescence microscopes and will contribute to improved scientific rigor and reproducibility.
Collapse
Affiliation(s)
- Benjamin Abrams
- Life Sciences Microscopy Center, 150 Sinsheimer Labs, University of California, Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA, RRID:SCR_021135
| | - Thomas Pengo
- Informatics Institute, University of Minnesota Twin Cities, Cancer and Cardiovascular Research Building, 2231 6th St SE, Minneapolis, MN 55449, USA
| | - Tse-Luen Wee
- Advanced BioImaging Facility (ABIF), McGill University, 3649 Prom, Sir William Osler, Bellini Building, Room 137, Montreal, QC H3G 0B1, Canada, RRID:SCR_017697
- Department of Physiology, McGill University, Montreal, QC
- Current affiliation: St. Giles Foundation Advanced Microscopy Center, Cold Spring Harbor Laboratory, One Bungtown Rd., Cold Spring Harbor, NY, 11724, USA, RRID:SCR_023023
| | - Rebecca C. Deagle
- Advanced BioImaging Facility (ABIF), McGill University, 3649 Prom, Sir William Osler, Bellini Building, Room 137, Montreal, QC H3G 0B1, Canada, RRID:SCR_017697
- Department of Physiology, McGill University, Montreal, QC
| | - Nelly Vuillemin
- Advanced BioImaging Facility (ABIF), McGill University, 3649 Prom, Sir William Osler, Bellini Building, Room 137, Montreal, QC H3G 0B1, Canada, RRID:SCR_017697
- Department of Physiology, McGill University, Montreal, QC
| | - Linda M. Callahan
- Department of Neuroscience, Del Monte Institute for Neuroscience, Univ. Rochester Medical Center, Rochester, NY 14642, USA
| | - Megan A. Smith
- Advanced BioImaging Facility (ABIF), McGill University, 3649 Prom, Sir William Osler, Bellini Building, Room 137, Montreal, QC H3G 0B1, Canada, RRID:SCR_017697
| | - Kristopher E. Kubow
- Biology Department, James Madison University, Bioscience Building, 951 Carrier Drive, Harrisonburg, VA 22807, USA, RRID:SCR_021904
| | - Anne-Marie Girard
- Center for Genome Research and Biocomputing, Oregon State University, 1500 SW Jefferson Way Corvallis, OR 97331, USA
| | - Joshua Z. Rappoport
- Center for Advanced Microscopy and Nikon Imaging Center, Feinberg School of Medicine, Northwestern Medicine, Northwestern University, Chicago, IL, USA
- Current affiliation: Boston College, 140 Commonwealth Avenue, Chestnut Hill, Massachusetts, USA
| | - Carol J. Bayles
- Institute of Biotechnology, Cornell University, Ithaca, NY, USA
| | - Lisa A. Cameron
- Light Microscopy Core Facility, Duke University, 4215 French Family Science Center, 124 Science Drive, Durham, NC 27708, USA
| | - Richard Cole
- New York State Dept of Health/Wadsworth Center, Advanced Light Microscopy & Image Analysis Core Facility, 150 New Scotland Ave, Albany, NY 12208, USA, RRID:SCR_021104
| | - Claire M. Brown
- Advanced BioImaging Facility (ABIF), McGill University, 3649 Prom, Sir William Osler, Bellini Building, Room 137, Montreal, QC H3G 0B1, Canada, RRID:SCR_017697
- Department of Physiology, McGill University, Montreal, QC
| |
Collapse
|
4
|
Torres-García E, Pinto-Cámara R, Linares A, Martínez D, Abonza V, Brito-Alarcón E, Calcines-Cruz C, Valdés-Galindo G, Torres D, Jabloñski M, Torres-Martínez HH, Martínez JL, Hernández HO, Ocelotl-Oviedo JP, Garcés Y, Barchi M, D’Antuono R, Bošković A, Dubrovsky JG, Darszon A, Buffone MG, Morales RR, Rendon-Mancha JM, Wood CD, Hernández-García A, Krapf D, Crevenna ÁH, Guerrero A. Extending resolution within a single imaging frame. Nat Commun 2022; 13:7452. [PMID: 36460648 PMCID: PMC9718789 DOI: 10.1038/s41467-022-34693-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 10/27/2022] [Indexed: 12/05/2022] Open
Abstract
The resolution of fluorescence microscopy images is limited by the physical properties of light. In the last decade, numerous super-resolution microscopy (SRM) approaches have been proposed to deal with such hindrance. Here we present Mean-Shift Super Resolution (MSSR), a new SRM algorithm based on the Mean Shift theory, which extends spatial resolution of single fluorescence images beyond the diffraction limit of light. MSSR works on low and high fluorophore densities, is not limited by the architecture of the optical setup and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image stacks, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other SRM approaches. Along with its wide accessibility, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.
Collapse
Affiliation(s)
- Esley Torres-García
- grid.412873.b0000 0004 0484 1712Centro de Investigación en Ciencias, Instituto de Investigación en Ciencias Básicas y Aplicadas, Universidad Autónoma del Estado de Morelos, Cuernavaca, Morelos Mexico ,grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Raúl Pinto-Cámara
- grid.412873.b0000 0004 0484 1712Centro de Investigación en Ciencias, Instituto de Investigación en Ciencias Básicas y Aplicadas, Universidad Autónoma del Estado de Morelos, Cuernavaca, Morelos Mexico ,grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Alejandro Linares
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico ,grid.144532.5000000012169920XAnalytical and Quantitative Light Microscopy, Marine Biological Laboratory, Woods Hole, MA USA
| | - Damián Martínez
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Víctor Abonza
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Eduardo Brito-Alarcón
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Carlos Calcines-Cruz
- grid.9486.30000 0001 2159 0001Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México, Mexico
| | - Gustavo Valdés-Galindo
- grid.9486.30000 0001 2159 0001Departamento de Química de Biomacromoléculas, Instituto de Química. Universidad Nacional Autónoma de México, Ciudad de México, Mexico
| | - David Torres
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Martina Jabloñski
- grid.464644.00000 0004 0637 7271Instituto de Biología y Medicina Experimental (IBYME‐CONICET), Buenos Aires, Argentina
| | - Héctor H. Torres-Martínez
- grid.9486.30000 0001 2159 0001Departamento de Biología Molecular de Plantas, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - José L. Martínez
- grid.9486.30000 0001 2159 0001Departamento de Genética del Desarrollo y Fisiología Molecular, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Haydee O. Hernández
- grid.9486.30000 0001 2159 0001Instituto de Investigaciones en Matemáticas Aplicadas y en Sistemas, Universidad Nacional Autónoma de México, Ciudad de México, Mexico
| | - José P. Ocelotl-Oviedo
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Yasel Garcés
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico ,grid.9486.30000 0001 2159 0001Departamento de Genética del Desarrollo y Fisiología Molecular, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Marco Barchi
- grid.6530.00000 0001 2300 0941Department of Biomedicine and Prevention, Faculty of Medicine, University of Rome Tor Vergata, Rome, Italy
| | | | - Ana Bošković
- grid.418924.20000 0004 0627 3632Neurobiology and Epigenetics Unit, European Molecular Biology Laboratory, Monterotondo, Rome Italy
| | - Joseph G. Dubrovsky
- grid.9486.30000 0001 2159 0001Departamento de Biología Molecular de Plantas, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Alberto Darszon
- grid.9486.30000 0001 2159 0001Departamento de Genética del Desarrollo y Fisiología Molecular, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Mariano G. Buffone
- grid.464644.00000 0004 0637 7271Instituto de Biología y Medicina Experimental (IBYME‐CONICET), Buenos Aires, Argentina
| | - Roberto Rodríguez Morales
- grid.472559.80000 0004 0498 8706Instituto de Cibernética, Matemática y Física, Ciudad de la Habana, Cuba
| | - Juan Manuel Rendon-Mancha
- grid.412873.b0000 0004 0484 1712Centro de Investigación en Ciencias, Instituto de Investigación en Ciencias Básicas y Aplicadas, Universidad Autónoma del Estado de Morelos, Cuernavaca, Morelos Mexico
| | - Christopher D. Wood
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| | - Armando Hernández-García
- grid.9486.30000 0001 2159 0001Departamento de Química de Biomacromoléculas, Instituto de Química. Universidad Nacional Autónoma de México, Ciudad de México, Mexico
| | - Diego Krapf
- grid.47894.360000 0004 1936 8083Electrical and Computer Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, CO USA
| | - Álvaro H. Crevenna
- grid.418924.20000 0004 0627 3632Neurobiology and Epigenetics Unit, European Molecular Biology Laboratory, Monterotondo, Rome Italy
| | - Adán Guerrero
- grid.9486.30000 0001 2159 0001Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México, Cuernavaca, Morelos Mexico
| |
Collapse
|
5
|
Kopanchuk S, Vavers E, Veiksina S, Ligi K, Zvejniece L, Dambrova M, Rinken A. Intracellular dynamics of the Sigma-1 receptor observed with super-resolution imaging microscopy. PLoS One 2022; 17:e0268563. [PMID: 35584184 PMCID: PMC9116656 DOI: 10.1371/journal.pone.0268563] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 05/03/2022] [Indexed: 12/05/2022] Open
Abstract
Sigma-1 receptor (Sig1R) is an endoplasmic reticulum (ER)-related membrane protein, that forms heteromers with other cellular proteins. As the mechanism of action of this chaperone protein remains unclear, the aim of the present study was to detect and analyze the intracellular dynamics of Sig1R in live cells using super-resolution imaging microscopy. For that, the Sig1R-yellow fluorescent protein conjugate (Sig1R-YFP) together with fluorescent markers of cell organelles were transfected into human ovarian adenocarcinoma (SK-OV-3) cells with BacMam technology. Sig1R-YFP was found to be located mainly in the nuclear envelope and in both tubular and vesicular structures of the ER but was not detected in the plasma membrane, even after activation of Sig1R with agonists. The super-resolution radial fluctuations approach (SRRF) performed with a highly inclined and laminated optical sheet (HILO) fluorescence microscope indicated substantial overlap of Sig1R-YFP spots with KDEL-mRFP, slight overlap with pmKate2-mito and no overlap with the markers of endosomes, peroxisomes, lysosomes, or caveolae. Activation of Sig1R with (+)-pentazocine caused a time-dependent decrease in the overlap between Sig1R-YFP and KDEL-mRFP, indicating that the activation of Sig1R decreases its colocalization with the marker of vesicular ER and does not cause comprehensive translocations of Sig1R in cells.
Collapse
Affiliation(s)
| | - Edijs Vavers
- Latvian Institute of Organic Synthesis, Riga, Latvia
- Riga Stradins University, Riga, Latvia
| | - Santa Veiksina
- University of Tartu, Institute of Chemistry, Tartu, Estonia
| | - Kadri Ligi
- University of Tartu, Institute of Chemistry, Tartu, Estonia
| | | | - Maija Dambrova
- Latvian Institute of Organic Synthesis, Riga, Latvia
- Riga Stradins University, Riga, Latvia
| | - Ago Rinken
- University of Tartu, Institute of Chemistry, Tartu, Estonia
| |
Collapse
|
6
|
Pushkina AA, Maltese G, Costa-Filho JI, Patel P, Lvovsky AI. Superresolution Linear Optical Imaging in the Far Field. PHYSICAL REVIEW LETTERS 2021; 127:253602. [PMID: 35029451 DOI: 10.1103/physrevlett.127.253602] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 08/03/2021] [Accepted: 11/16/2021] [Indexed: 06/14/2023]
Abstract
The resolution of optical imaging devices is ultimately limited by the diffraction of light. To circumvent this limit, modern superresolution microscopy techniques employ active interaction with the object by exploiting its optical nonlinearities, nonclassical properties of the illumination beam, or near field probing. Thus, they are not applicable whenever such interaction is not possible, for example, in astronomy or noninvasive biological imaging. Far field, linear optical superresolution techniques based on passive analysis of light coming from the object would cover these gaps. In this Letter, we present the first proof-of-principle demonstration of such a technique for 2D imaging. It works by accessing information about spatial correlations of the image optical field and, hence, about the object itself via measuring projections onto Hermite-Gaussian transverse spatial modes. With a basis of 21 spatial modes in both transverse dimensions, we perform two-dimensional imaging with twofold resolution enhancement beyond the diffraction limit.
Collapse
Affiliation(s)
- A A Pushkina
- Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom
| | - G Maltese
- Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom
| | - J I Costa-Filho
- Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom
| | - P Patel
- Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom
| | - A I Lvovsky
- Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom
- Russian Quantum Center, 100 Novaya Street, Skolkovo, Moscow 143025, Russia
- P. N. Lebedev Physics Institute, Leninskiy prospect 53, Moscow 119991, Russia
| |
Collapse
|
7
|
Žurauskas M, Alex A, Park J, Hood SR, Boppart SA. Fluorescent nanodiamonds for characterization of nonlinear microscopy systems. PHOTONICS RESEARCH 2021; 9:2309-2318. [PMID: 37181134 PMCID: PMC10174270 DOI: 10.1364/prj.434236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Characterizing the performance of fluorescence microscopy and nonlinear imaging systems is an essential step required for imaging system optimization and quality control during longitudinal experiments. Emerging multimodal nonlinear imaging techniques require a new generation of microscopy calibration targets that are not susceptible to bleaching and can provide a contrast across the multiple modalities. Here, we present a nanodiamond-based calibration target for microscopy, designed for facilitating reproducible measurements at the object plane. The target is designed to support day-to-day instrumentation development efforts in microscopy laboratories. The images of a phantom contain information about the imaging performance of a microscopy system across multiple spectral windows and modalities. Since fluorescent nanodiamonds are not prone to bleaching, the proposed imaging target can serve as a standard, shelf-stable sample to provide rapid reference measurements for ensuring consistent performance of microscopy systems in microscopy laboratories and imaging facilities.
Collapse
Affiliation(s)
- Mantas Žurauskas
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- GSK Center for Optical Molecular Imaging, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
| | - Aneesh Alex
- GSK Center for Optical Molecular Imaging, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- GlaxoSmithKline, Collegeville, Pennsylvania 19426, USA
| | - Jaena Park
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
| | - Steve R. Hood
- GSK Center for Optical Molecular Imaging, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- GlaxoSmithKline, Stevenage, Hertfordshire SG1 2NY, UK
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- GSK Center for Optical Molecular Imaging, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
- Corresponding author:
| |
Collapse
|
8
|
Recent advances in the standardization of fluorescence microscopy for quantitative image analysis. Biophys Rev 2021; 14:33-39. [DOI: 10.1007/s12551-021-00871-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 10/22/2021] [Indexed: 12/19/2022] Open
|
9
|
van der Wee EB, Fokkema J, Kennedy CL, Del Pozo M, de Winter DAM, Speets PNA, Gerritsen HC, van Blaaderen A. 3D test sample for the calibration and quality control of stimulated emission depletion (STED) and confocal microscopes. Commun Biol 2021; 4:909. [PMID: 34302049 PMCID: PMC8302645 DOI: 10.1038/s42003-021-02432-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 07/05/2021] [Indexed: 02/07/2023] Open
Abstract
Multiple samples are required to monitor and optimize the quality and reliability of quantitative measurements of stimulated emission depletion (STED) and confocal microscopes. Here, we present a single sample to calibrate these microscopes, align their laser beams and measure their point spread function (PSF) in 3D. The sample is composed of a refractive index matched colloidal crystal of silica beads with fluorescent and gold cores. The microscopes can be calibrated in three dimensions using the periodicity of the crystal; the alignment of the laser beams can be checked using the reflection of the gold cores; and the PSF can be measured at multiple positions and depths using the fluorescent cores. It is demonstrated how this sample can be used to visualize and improve the quality of STED and confocal microscopy images. The sample is adjustable to meet the requirements of different NA objectives and microscopy techniques and additionally can be used to evaluate refractive index mismatches as a function of depth quantitatively.
Collapse
Affiliation(s)
- Ernest B van der Wee
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Jantina Fokkema
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
| | - Chris L Kennedy
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
| | - Marc Del Pozo
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
- Stimuli-responsive Functional Materials and Devices, Department of Chemical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - D A Matthijs de Winter
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
- Environmental Hydrogeology, Department of Earth Sciences, Utrecht University, Utrecht, the Netherlands
| | - Peter N A Speets
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Hans C Gerritsen
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands
| | - Alfons van Blaaderen
- Soft Condensed Matter and Molecular Biophysics, Debye Institute for Nanomaterials Science, Utrecht University, Utrecht, the Netherlands.
| |
Collapse
|
10
|
Olevsko I, Szederkenyi K, Corridon J, Au A, Delhomme B, Bastien T, Fernandes J, Yip C, Oheim M, Salomon A. A simple, inexpensive and multi-scale 3-D fluorescent test sample for optical sectioning microscopies. Microsc Res Tech 2021; 84:2625-2635. [PMID: 34008289 DOI: 10.1002/jemt.23813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 04/05/2021] [Accepted: 04/27/2021] [Indexed: 11/11/2022]
Abstract
Fluorescence standards allow for quality control and for the comparison of data sets across instruments and laboratories in applications of quantitative fluorescence. For example, users of microscopy core facilities can expect a homogenous and time-invariant illumination and an uniform detection sensitivity, which are prerequisites for imaging analysis, tracking or fluorimetric pH or Ca2+ -concentration measurements. Similarly, confirming the three-dimensional (3-D) resolution of optical sectioning microscopes calls for a regular calibration with a standardized point source. The test samples required for such measurements are typically different ones, they are often expensive and they depend much on the very microscope technique used. Similarly, the ever-increasing choice among microscope techniques and geometries increases the demand for comparison across instruments. Here, we advocate and demonstrate the multiple uses of a surprisingly versatile and simple 3-D test sample that can complement existing and much more expensive calibration samples: commercial tissue paper labeled with a fluorescent highlighter pen. We provide relevant sample characteristics and show examples ranging from the sub-μm to cm scale, acquired on epifluorescence, confocal, image scanning, two-photon (2P) and light-sheet microscopes.
Collapse
Affiliation(s)
- Ilya Olevsko
- Department of Chemistry, Bar-Ilan University, Institute of Nanotechnology and Advanced Materials (BINA), Ramat-Gan, Israel
| | - Kaitlin Szederkenyi
- Université de Paris, CNRS, SPPIN - Saints-Pères Paris Institute for the Neurosciences, Paris, France.,University of Toronto, Donnelly Centre for Cellular & Biomolecular Research, Toronto, Ontario, Canada
| | - Jennifer Corridon
- Université de Paris, CNRS UMS 2009, INSERM US 36, BioMedTech Facilities, Paris, France.,Université de Paris, Service Commun de Microscopie (SCM), Paris, France
| | - Aaron Au
- University of Toronto, Donnelly Centre for Cellular & Biomolecular Research, Toronto, Ontario, Canada
| | - Brigitte Delhomme
- Université de Paris, CNRS, SPPIN - Saints-Pères Paris Institute for the Neurosciences, Paris, France
| | - Thierry Bastien
- Université de Paris, CNRS UMS 2009, INSERM US 36, BioMedTech Facilities, Paris, France.,Université de Paris, Plateforme de Prototypage, Paris, France
| | - Julien Fernandes
- UTechS Photonic BioImaging, C2RT, Institut Pasteur, Paris, France
| | - Christopher Yip
- University of Toronto, Donnelly Centre for Cellular & Biomolecular Research, Toronto, Ontario, Canada
| | - Martin Oheim
- Université de Paris, CNRS, SPPIN - Saints-Pères Paris Institute for the Neurosciences, Paris, France.,Université de Paris, CNRS UMS 2009, INSERM US 36, BioMedTech Facilities, Paris, France.,Université de Paris, Service Commun de Microscopie (SCM), Paris, France
| | - Adi Salomon
- Department of Chemistry, Bar-Ilan University, Institute of Nanotechnology and Advanced Materials (BINA), Ramat-Gan, Israel.,Université de Paris, CNRS, SPPIN - Saints-Pères Paris Institute for the Neurosciences, Paris, France
| |
Collapse
|
11
|
You S, Chao J, Cohen EAK, Ward ES, Ober RJ. Microscope calibration protocol for single-molecule microscopy. OPTICS EXPRESS 2021; 29:182-207. [PMID: 33362108 PMCID: PMC7920521 DOI: 10.1364/oe.408361] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Single-molecule microscopy allows for the investigation of the dynamics of individual molecules and the visualization of subcellular structures at high spatial resolution. For single-molecule imaging experiments, and particularly those that entail the acquisition of multicolor data, calibration of the microscope and its optical components therefore needs to be carried out at a high level of accuracy. We propose here a method for calibrating a microscope at the nanometer scale, in the sense of determining optical aberrations as revealed by point source localization errors on the order of nanometers. The method is based on the imaging of a standard sample to detect and evaluate the amount of geometric aberration introduced in the optical light path. To provide support for multicolor imaging, it also includes procedures for evaluating the geometric aberration caused by a dichroic filter and the axial chromatic aberration introduced by an objective lens.
Collapse
Affiliation(s)
- Sungyong You
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Molecular and Cellular Medicine, Texas A&M University Health Science Center, College Station, TX 77843, USA
| | - Jerry Chao
- Astero Technologies LLC, College Station, TX 77845, USA
| | | | - E. Sally Ward
- Department of Molecular and Cellular Medicine, Texas A&M University Health Science Center, College Station, TX 77843, USA
- Centre for Cancer Immunology, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK
| | - Raimund J. Ober
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Molecular and Cellular Medicine, Texas A&M University Health Science Center, College Station, TX 77843, USA
- Centre for Cancer Immunology, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK
| |
Collapse
|
12
|
Fu Y, Liu X, Wang Y, He Y, Feng G, Wu H, Zheng C, Li P, Gan H. Miniaturized integrating sphere light sources based on LEDs for radiance responsivity calibration of optical imaging microscopes. OPTICS EXPRESS 2020; 28:32199-32213. [PMID: 33115182 DOI: 10.1364/oe.403899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 09/20/2020] [Indexed: 06/11/2023]
Abstract
LED-based integrating sphere light sources (LED-ISLSs) in the size of typical microscope slides were developed to calibrate the radiance responsivity of optical imaging microscopes. Each LED-ISLS consists of a miniaturized integrating sphere with a diameter of 4 mm, an LED chip integrated on a printed circuit board, and a thin circular aperture with a diameter of 1 mm as the exit port. The non-uniformity of the radiant exitance of the LED-ISLSs was evaluated to be 0.8%. The normal radiance of the LED-ISLSs in the range of (5∼69) W m-2 sr-1 was measured with a standard uncertainty of 1.3% using two precision apertures and a standard silicon photodetector whose spectral responsivity is traceable to an absolute cryogenic radiometer. The LED-ISLSs were applied to calibrate the radiance responsivity of a home-built optical imaging microscope with a standard uncertainty of 2.6∼2.9%. The LED-ISLSs offer a practical way to calibrate the radiance responsivity of various optical imaging microscopes for results comparison and information exchange.
Collapse
|
13
|
Gintoli M, Mohanan S, Salter P, Williams E, Beard JD, Jekely G, Corbett AD. Spinning disk-remote focusing microscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:2874-2888. [PMID: 32637230 PMCID: PMC7316025 DOI: 10.1364/boe.389904] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 04/23/2020] [Accepted: 04/26/2020] [Indexed: 06/11/2023]
Abstract
Fast confocal imaging was achieved by combining remote focusing with differential spinning disk optical sectioning to rapidly acquire images of live samples at cellular resolution. Axial and lateral full width half maxima less than 5 µm and 490 nm respectively are demonstrated over 130 µm axial range with a 256 × 128 µm field of view. A water-index calibration slide was used to achieve an alignment that minimises image volume distortion. Application to live biological samples was demonstrated by acquiring image volumes over a 24 µm axial range at 1 volume/s, allowing for the detection of calcium-based neuronal activity in Platynereis dumerilii larvae.
Collapse
Affiliation(s)
- Michele Gintoli
- Department of Physics and Astronomy, University of Exeter, Exeter, EX4 4QL, UK
| | - Sharika Mohanan
- Department of Physics and Astronomy, University of Exeter, Exeter, EX4 4QL, UK
| | - Patrick Salter
- Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK
| | | | - James D. Beard
- Living Systems Institute, University of Exeter, Exeter, EX4 4QD, UK
| | - Gaspar Jekely
- Living Systems Institute, University of Exeter, Exeter, EX4 4QD, UK
| | | |
Collapse
|
14
|
Lawton PF, Buckley C, Saunter CD, Wilson C, Corbett AD, Salter PS, McCarron JG, Girkin JM. Multi-plane remote refocusing epifluorescence microscopy to image dynamic Ca 2 + events. BIOMEDICAL OPTICS EXPRESS 2019; 10:5611-5624. [PMID: 31799034 PMCID: PMC6865095 DOI: 10.1364/boe.10.005611] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 09/12/2019] [Accepted: 09/12/2019] [Indexed: 05/26/2023]
Abstract
Rapid imaging of multiple focal planes without sample movement may be achieved through remote refocusing, where imaging is carried out in a plane conjugate to the sample plane. The technique is ideally suited to studying the endothelial and smooth muscle cell layers of blood vessels. These are intrinsically linked through rapid communication and must be separately imaged at a sufficiently high frame rate in order to understand this biologically crucial interaction. We have designed and implemented an epifluoresence-based remote refocussing imaging system that can image each layer at up to 20fps using different dyes and excitation light for each layer, without the requirement for optically sectioning microscopy. A novel triggering system is used to activate the appropriate laser and image acquisition at each plane of interest. Using this method, we are able to achieve axial plane separations down to 15 μ m, with a mean lateral stability of ≤ 0.32 μ m displacement using a 60x, 1.4NA imaging objective and a 60x, 0.7NA reimaging objective. The system allows us to image and quantify endothelial cell activity and smooth muscle cell activity at a high framerate with excellent lateral and good axial resolution without requiring complex beam scanning confocal microscopes, delivering a cost effective solution for imaging two planes rapidly. We have successfully imaged and analysed Ca 2 + activity of the endothelial cell layer independently of the smooth muscle layer for several minutes.
Collapse
Affiliation(s)
- Penelope F. Lawton
- Department of Physics, Durham University, South Road, Durham, DH1 3LE, UK
| | - Charlotte Buckley
- Strathclyde Institute of Pharmacy & Biomedical Sciences, University of Strathclyde, 161 Cathedral Street, Glasgow, G4 0RE, UK
| | - Chris D. Saunter
- Department of Physics, Durham University, South Road, Durham, DH1 3LE, UK
| | - Calum Wilson
- Strathclyde Institute of Pharmacy & Biomedical Sciences, University of Strathclyde, 161 Cathedral Street, Glasgow, G4 0RE, UK
| | - Alexander D. Corbett
- Department of Physics, University of Exeter, North Park Road, Exeter, EX4 4QL, UK
| | - Patrick S. Salter
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
| | - John G. McCarron
- Strathclyde Institute of Pharmacy & Biomedical Sciences, University of Strathclyde, 161 Cathedral Street, Glasgow, G4 0RE, UK
| | - John M. Girkin
- Department of Physics, Durham University, South Road, Durham, DH1 3LE, UK
| |
Collapse
|
15
|
Dai Y, Antonello J, Booth MJ. Calibration of a phase-only spatial light modulator for both phase and retardance modulation. OPTICS EXPRESS 2019; 27:17912-17926. [PMID: 31252743 DOI: 10.1364/oe.27.017912] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Liquid crystal spatial light modulators (SLMs) are usually configured and calibrated for phase modulation. However, as they are variable retarders, they also have application as polarization modulators. We show that conventional phase-only calibrations are insufficient for this purpose, and a separate retardance calibration is needed. To overcome this shortcoming we report a simple Twyman-Green interferometer-based setup to realize SLM phase and retardance calibration. For phase calibration, we identify the non-linear, spatially variant response to the drive voltage of the SLM using fringe analysis and both horizontally and vertically polarized incident light. For retardance calibration, we use incident light polarized at 45° and assess the intensity variation. The methods presented are compatible with in situ calibration of SLMs.
Collapse
|
16
|
Lin R, Clowsley AH, Lutz T, Baddeley D, Soeller C. 3D super-resolution microscopy performance and quantitative analysis assessment using DNA-PAINT and DNA origami test samples. Methods 2019; 174:56-71. [PMID: 31129290 DOI: 10.1016/j.ymeth.2019.05.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/06/2019] [Accepted: 05/20/2019] [Indexed: 12/29/2022] Open
Abstract
Assessment of the imaging quality in localisation-based super-resolution techniques relies on an accurate characterisation of the imaging setup and analysis procedures. Test samples can provide regular feedback on system performance and facilitate the implementation of new methods. While multiple test samples for regular, 2D imaging are available, they are not common for more specialised imaging modes. Here, we analyse robust test samples for 3D and quantitative super-resolution imaging, which are straightforward to use, are time- and cost-effective and do not require experience beyond basic laboratory and imaging skills. We present two options for assessment of 3D imaging quality, the use of microspheres functionalised for DNA-PAINT and a commercial DNA origami sample. A method to establish and assess a qPAINT workflow for quantitative imaging is demonstrated with a second, commercially available DNA origami sample.
Collapse
Affiliation(s)
- Ruisheng Lin
- Living Systems Institute and Biomedical Physics, University of Exeter, United Kingdom
| | - Alexander H Clowsley
- Living Systems Institute and Biomedical Physics, University of Exeter, United Kingdom
| | - Tobias Lutz
- Living Systems Institute and Biomedical Physics, University of Exeter, United Kingdom
| | - David Baddeley
- Department of Cell Biology, Yale University, USA; Bioengineering Institute, University of Auckland, New Zealand
| | - Christian Soeller
- Living Systems Institute and Biomedical Physics, University of Exeter, United Kingdom.
| |
Collapse
|
17
|
Procedure for Calibrating the Z-axis of a Confocal Microscope: Application for the Evaluation of Structured Surfaces. SENSORS 2019; 19:s19030527. [PMID: 30691214 PMCID: PMC6387104 DOI: 10.3390/s19030527] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 01/22/2019] [Accepted: 01/24/2019] [Indexed: 11/29/2022]
Abstract
This work describes a method for the metrological characterization of structured surfaces using a confocal microscope. The proposed method is based on the calculation of texture parameters established in ISO 25178-2:2012. To ensure the traceability of these parameters, a procedure for the calibration of the Z-axis of the confocal microscope is proposed. The calculation of uncertainty associated with each parameter employs the Monte Carlo method, as well as the concept of a virtual instrument. The validity of the algorithms has been verified through the use of synthetic data provided by the National Institute of Standards and Technology (NIST) and physical standards, with minimum differences being obtained between the certified values and calculated or measured values. Finally, using the proposed method, the topography of a structured surface manufactured by laser machining is evaluated, obtaining the most used roughness parameters, as well as their measurement uncertainties and possible correlations. In general, it can be affirmed that it is possible to obtain metrologically reliable results with the proposed method.
Collapse
|